DATA SHEET Part Number: SL08 4R003 Ordering Different Lead Types: Inside Kinked Leads Outside Kinked Leads Use -A after Ametherm's part # Not Available For example: to order an inside kinked lead use part number SL08 4R003-A D D D T C B L S S S STRAIGHT LEADS OUTSIDE KINKED LEADS INSIDE KINKED LEADS Electrical Specifications: Mechanical Specifications: Resistance @ 25C Max Steady State Current Up to 65C Max Recommended Energy Rating (Joules) Actual Failure Point of Instantaneous Energy (Joules) Resistance @ 100% of Max Current Resistance @ 50% of Max Current Body Temperature @ 100% Current Rating Dissipation Constant Thermal Time Constant Max Operating Temperature Temperature Coefficient 4.0 20% 3.0 A 10.0 J 20.0 J 0.234 0.320 122 C 9.0mW/C 20 seconds 160 C -3.0%/C CSA File #: CA 118061 D T Lead Diameter S L Straight Leads Coating Run Down B C 8.0 0.5 mm 4.0 0.5 mm 0.5 0.1 mm 6.4 2.0 mm 38.0 3.0 mm 5.0 1.0 mm 5.00 1.00 mm 1.50 0.2 mm Revision Date: March 19, 2003 Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701 Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670 www.ametherm.com