The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. The MPU150-4530G and MPU150-4350G provide high current +3.3 V and +5 V on a single platform to support mixed-mode, high-speed digital circuitry. Bel Power Solutions unique dual converter architecture combines high reliability with exceptional regulation. All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch. The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input. RoHS Compliant Power Factor Correction (PFC) Low-profile height fits 1U constraints Dual main outputs provide 3.3 V and 5 V for mixed mode applications Single wire current sense on outputs V1 and V2 Remote sense on outputs V1 and V2 Overtemperature, overload, and overvoltage protection Available with metric or SAE mountings Greater than 340000 Hours MTBF MDU150 models have 48 VDC input Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 (c) 2015 Bel Power Solutions, Inc. North America +1 866 513 2839 BCD.00603_AA 2 180 W with 300 LFM Forced-Air Cooling MODEL6 OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT 1 MPU150-S259G 12V 11.6V to 16V 15A 3 MPU150-S262G 24V 22.8V to 29.2V 7.5A 3 MPU150-S261G 48V 45V to 56V 3.75A 3 LINE LOAD REGULATION REGULATION RIPPLE & NOISE % pk-pk 2 INITIAL SETTING ACCURACY 0.1% 1% 1% 11.97V to 12.03V 0.1% 1% 1% 23.95V to 24.05V 0.1% 1% 1% 47.9V to 48.1V 150 W with 300 LFM Forced-Air Cooling - Isolated V3 and V4 can be used as positive or negative outputs MODEL6 MPU150-3300G MPU150-3524G MPU150-4000G MPU150-4230G MPU150-4350G MPU150-4530G OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE % pk-pk 2 INITIAL SETTING ACCURACY +3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V +12V Fixed 2A 0.4% 3% 1% 11.76V to 12.24V +5V 5.0V to 5.5V 17.5A 0.4% 1% 1% 4.98V to 5.02V +12V 10.8V to 13.2V 4A 0.4% 3% 1% 11.94V to 12.06V 23.52V to 24.48V +24V Fixed 2A 0.4% 3% 1% +5V 5.0V to 5.5V 30A 4 0.4% 1% 1% 4.98V to 5.02V +12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V +2.5V 2.25V to 3.0V 30A 4 0.8% 2% 2% 2.49V to 2.51V +3.3V 3.15V to 3.8V 15A 4 0.6% 1.5% 1.5% 3.28V to 3.32V 12V 10.8V to 13.2V 4A 5 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A 5 0.4% 1% 1% 4.98V to 5.0V +3.3V 3.15V to 3.80V 30A 4 0.6% 1.5% 1% 3.28V to 3.32V +5V 5.0V to 5.5V 15A 4 0.4% 1% 1% 5.00V to 5.04V 12V 10.8V to 13.2V 3A 5 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 5 0.4% 7% 1% 11.94V to 12.06V +5V 5.0V to 5.5V 30A 4 0.4% 1% 1% 4.98V to 5.02V 4 +3.3V 3.15V to 3.60V 15A 0.6% 1.5% 1.5% 3.28V to 3.32V 12V 10.8V to 13.2V 3A 5 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 5 0.4% 7% 1% 11.94V to 12.06V NOTES: 1 2 3 4 5 6 The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be applied from the input side of the power supply blowing towards the output. Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Total power of 180 Watts. Total current between V1 and V2 is 30A, maximum rating. Total current between V3 and V4 is 5A, maximum rating. Non-G models use lead solder exemption and are not recommended for new designs. tech.support@psbel.com 3 150 W with 300 LFM Forced-Air Cooling - Isolated V3 and V4 can be used as positive or negative outputs MODEL6 MDU150-3300G OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE % pk-pk 2 INITIAL SETTING ACCURACY +3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V +12V N/A 2A 0.4% 3% 1% 11.76V to 12.24V 0.4% 1% 1% 4.98V to 5.02V 30A 3 +5V 5.0V to 5.5V +12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A MDU150-4000G +2.5V 2.25V to 3.0V 0.4% 1% 1% 4.98V to 5.02V 30A 3 2% 2% 2% 2.49V to 2.51V 3 1.5% 1.5% 1.5% 3.28V to 3.32V 1% 1% 1% 11.94V to 12.06V +3.3V 3.15V to 3.8V 15A 12V 10.8V to 13.2V 3A 5V 5.0V to 5.5 V 2A MDU150-4230G +3.3V 3.15V to 3.8V 1% 1% 1% 4.98V to 5.0V 30A 5 1.5% 1.5% 1% 3.28V to 3.32V 15A 5 +5V 5.0V to 5.5V 1% 1% 1% 5.00V to 5.04V 12V 10.8V to 13.2V 3A 4 7% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 4 7% 7% 1% 11.94V to 12.06V +5V 5.0V to 5.5V 30A 3 0.4% 1% 1% 4.98V to 5.02V +3.3V 3.15V to 3.60V 15A 3 0.6% 1.5% 1.5% 3.28V to 3.32V 12V 10.8V to 13.2V 3A 4 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 4 0.4% 7% 1% 11.94V to 12.06V MDU150-4350G MDU150-4530G NOTES: 1 2 3 4 5 6 The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be applied from the input side of the power supply blowing towards the output. Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Total current between V1 and V2 is 30A, maximum rating. Total current between V3 and V4 is 5A, maximum rating. Total current between V1 and V2 is 40A, maximum rating. Non-G models use lead solder exemption OPTIONS SUFFIXES TO ADD TO PART NUMBER Metric Mounting Add "M" as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. RoHS lead solder exempt No RoHS suffix character required. RoHS compliant for all 6 substances Add "G" as the last character of the part number. tech.support@psbel.com 4 PARAMETER CONDITIONS / DESCRIPTION Input Voltage - AC Continuous input range. Input Frequency AC input. MIN MPU150-4350G All other models MPU150 Hold-up Time After last AC line peak at 150 watts. Input Current 85 VAC at full rated load. Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25C. Power Factor Per EN61000-3-2. Switching frequency of main output transformer. Switching frequency of secondary transformer. Switching frequency of Power Factor Correction circuit. Operating Frequency PARAMETER CONDITIONS / DESCRIPTION MAX UNITS 85 NOM 264 VAC 47 17.5 20 63 Hz ms 0.95 100 65 3.0 ARMS 35 APK W/VA 120 90 kHz MAX UNITS 75 VDC 60 MIN NOM Input Voltage - DC Continuous input range. 36 Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC Hold-up Time At 150 watts, over DC input range. 20 ms Input Current 36 VDC at full rated load. Input Protection Non-user serviceable internally located AC input line fuse. Operating Frequency Switching frequency of main output transformer. Switching frequency of secondary transformer. Inrush Current Consult factory. PARAMETER Turn-on Delay CONDITIONS / DESCRIPTION Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. Minimum load required to maintain Triple output models V1 regulation on, V2 at maximum load. Quad output models V1 Minimum load required on single Single output models V1 output models. Minimum load required to maintain Quad output models V3 regulation on V4 at maximum load. Triple output models V3 Full load, 20 MHz bandwidth. With 300 LFM forced air cooling. (Note 1) Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes over the specified. Input range, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50100% load change, 5% max. deviation. Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. Efficiency Minimum Load, V1 Minimum Load, V3 Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response 6.4 ARMS 100 70 MIN NOM 65 75 kHz MAX UNITS % 4 3 0 A 0.3 0 A See Model Selection Charts 150 0 Watts 3 5 % See Model Selection Charts 500 s 2 s 50 ms NOTE 1: This product is not rated for convection applications. tech.support@psbel.com 5 PARAMETER Overvoltage Protection Overload Protection Overtemperature Protection Output Good Signal, Low to High Transition Input Power Fail Warning Current Share Remote Sense Inhibit PARAMETER CONDITIONS / DESCRIPTION 2.5 V output, V1 3.3 V output, V1 3.3 V output, V2 Latch style overvoltage protection. 5 V output, V1, V2 Available on V1, V2, all models, 12 V output, V2 and V3 on all models except 12 V output, V3 MPU150-3300G. MPU150-4350G 3.3 V output, V1 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. TTL compatible signal available for V1. Pull-up resistor is 10k. 3.3 V Signal is high when output is above the specified limits. 5V Signal shall remain low for 20 ms following loss of Output Good. TTL compatible logic signal. Time before regulation dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. Accuracy of shared current with up to 6 parallel units. Single wire current share on V1 and V2 with return via -Sense return. Available on V1 and V2. Total voltage compensation for cable losses with respect to the main output. Output voltage is inhibited by application of an external high (5V) signal. MIN 3.0 4.1 3.8 6.0 14 14 4.3 NOM MAX 3.25 4.65 4.2 6.4 16 19 4.65 3.16 3.25 4.75 4.90 UNITS V V 5 ms 10 500 mV MAX UNITS CONDITIONS / DESCRIPTION MIN Dielectric Withstand Voltage Electromagnetic Interference Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 MPU150 Input to output per EN60950. MDU150 FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. 2600 1544 B B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. 2 kV Input Transient Protection Per EN61000-4-5, class 3. 1 2 0.5 0.5 kV Insulation Resistance Input to output. Safety Approvals Leakage Current Per EN60950. MPU150: Line to Line MPU150: Line to Ground MDU150: Line to Line MDU150: Line to Ground NOM % VDC Class M 10 Dual output MPU150 at 264 VAC Single and triple output MPU150 at 264 VAC MDU150 at 72 VDC 22 1.7 mA (Not required by EN60950) tech.support@psbel.com 6 PARAMETER Altitude Operating Temperature CONDITIONS / DESCRIPTION Operating. Non-Operating. Derate linearly above 50C by 2.5% per C. MIN At 100% load At 50% load Storage Temperature NOM 0 0 -55 Temperature Coefficient 0C to 70C (after 15 minute warm-up). Relative Humidity Non-Condensing. Shock Peak acceleration. Vibration Random vibration, 10Hz to 2kHz, 3 axis. PARAMETER DESCRIPTION Dimensions 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2 lb (0.89 kg) 0.02 5 MAX 10k 40k 50 70 85 UNITS ASL Ft. C C 0.05 %/C 95 %RH 20 GPK 6 GRMS MATES WITH MOLEX: HOUSING SERIES 5264-N, P/N: 50-37-5103 (&) PINS SERIES 5263, P/N: 80-70-1040 (LOOSE) Figure 1. Mechanical Drawing - Single Output tech.support@psbel.com 7 CONNECTOR J1 (ALL MODELS) J300 MOLEX SERIES HOUSING PIN SERIES PINS (LOOSE) PINS (CHAIN) WIRE GAUGE 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWG 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG 5264-N 50-37-5103 5263 08-70-1040 08-70-1039 22-28AWG CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH Figure 2. Mechanical Drawing - Triple & Quad Output tech.support@psbel.com 8 CONNECTOR J1 (ALL MODELS) J2 (TRIPLE OUTPUT) J3 (TRIPLE OUTPUT) J3 (QUAD OUTPUT) J300 MOLEX SERIES HOUSING PIN SERIES PINS (LOOSE) PINS (CHAIN) WIRE GAUGE 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWG 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG 5051-N 22-01-1022 2759 08-50-0114 08-50-0113 22-30AWG 5051-N 22-01-1022 2759 08-65-0805 08-65-0804 22-30AWG 41695 09-50-8021 6838 08-50-0189 08-50-0187 18-20AWG 41695 09-50-8021 2478 08-50-0106 08-50-0105 18-20AWG 2139 09-50-3021 2478 08-50-0106 08-50-0105 18-20AWG 41695 09-50-8061 6838 08-50-0189 08-50-0187 18-20AWG 41695 09-50-8061 2478 08-50-0106 08-50-0105 18-20AWG 2139 09-50-3061 2478 08-50-0106 08-50-0105 18-20AWG 5264-N 50-37-5103 5263 08-70-1040 08-70-1039 22-28AWG CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com