A3P
Ordering Information
Tools
Specifications
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load: 5 A at 125 VAC
3 A at 250 VAC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
CCC (GB14048.5)
Standard Load: 3 A at 250 VAC
4 A at 30 VDC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Ratings
Contact Ratings
Silver Alloy Contacts (for Standard Loads)
Note: 1. The above values are for steady-state currents.
2. Inductive load: Power factor = 0.4; time constant = 7 ms.
3. The lamp load has an inrush current of 10 times the steady-state current.
4. The motor load has an inrush current of 6 times the steady-state current.
Standard testing condition
(1) Ambient temperature: 20 ± 2°C
(2) Ambient humidity: 65 ± 5%RH
(3) Operating frequency: 20 times/min.
Gold Alloy Contacts (for Microloads)
LED and Incandescent Lamp Ratings
LED for LED-lighted Models
LED for Chameleon Models
Incandescent Lamp
LED Lamp (for LED Lamp-lighted Models)
Characteristics
*1. With alternate operation models, 60 operations/minute max. One operation
cycle consists of set and reset operations.
*2. 600 VAC for microloads.
*3. With no incandescent lamp or LED lamp mounted.
Name Appearance Classification Model Application precautions
Extractor
--- A3PJ-5080
• Use to extract components when
replacing the Pushbutton.
• You can use the same Sockets for
the A3P Ultra Bright Lighted Push-
button Switches.
Rated
voltage
(V)
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5
3
0.7
0.5
3
2
1.3
0.8
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5
5
4
0.4
0.2
2
2
2
0.05
0.03
4
4
3
0.4
0.2
3
3
3
0.05
0.03
Rated voltage (V) 0.1 A at 30 VDC (resistive load);
0.1 A at 125 VAC (resistive load)
Minimum applicable load 1 mA at 5 VDC
Model A3PJ/M2PJ
A3PA/M2PA
Rated current Rated current
Applied
voltage
Rated
voltage
Single
screen
2-split
screen
Single
screen
2-split
screen
5 VDC±5% 5 VDC 80 mA --- 80 mA ---
12 VDC±5% 12 VDC 40 mA --- 40 mA ---
24 VDC±5% 24 VDC 20 mA 15 mA × 2 20 mA 13 mA × 2
Applied voltage Rated voltage Rated current
Green Red
12 VDC±5% 12 VDC 26 mA 20 mA
24 VDC±5% 24 VDC 13 mA 10 mA
Item Standard lamp Low-power lamp
Applied voltage Rated voltage Rated current
Model
Rated current
Model
5 VDC
6 V 200 mA SLL-06 100 mA
SLL-06H
12 VDC
14 V 80 mA SLL-14 40 mA
SLL-14H
24 VDC
28 V 40 mA SLL-28 25 mA
SLL-28H
Type
Applied voltage
Rated voltage Rated current
Model
DC only
5 VDC±5% 5 VDC 30 mA SLL-05E@
12 VDC±5% 12 VDC 15 mA SLL-12E@
24 VDC±5% 24 VDC 12.5 mA SLL-24E@
Operating frequency Mechanical 120 operations/minute max. *1
Electrical 30 operations/minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact
resistance
Standard load 40 mΩ max. (initial value)
Microload 40 mΩ max. (initial value)
Dielectric
strength
Between terminals of same polarity
1,000 VAC, 50/60 Hz for 1 minute
*
2
Between terminals of different polarity
2,000 VAC, 50/60 Hz for 1 minute
Between current-carrying metal
part and ground
2,000 VAC, 50/60 Hz for 1 minute
Between each terminal and
non-current-carrying metal part
2,000 VAC, 50/60 Hz for 1 minute
Between lamp terminals
1,000 VAC, 50/60 Hz for 1 minute *3
Vibration resistance Malfunction 10 to 55 Hz, 1.5 mm double am-
plitude (1 ms max.)
Shock resistance Destruction 500 m/s2 max.
Malfunction 200 m/s2 max. (1 ms max.)
Life expectancy Mechanical
Momentary operation models:
1,000,000 operations min.
Alternate operation models:
200,000 operations min.
(One operation consists of set
and reset operations.)
Electrical 100,000 operations min.
Weight Approx. 30 g
Inrush current
NC
Silver contact: 10 A max.
NO
Silver contact: 10 A max.
Ambient operating temperature
LED-lighted models:
−
10
°
C to 40
°
C
(with no icing or condensation)
Incandescent lamp-lighted models:
−
10
°
C to 50
°
C
(with no icing or condensation)
Ambient operating humidity 35% to 85%RH
Ambient storage temperature −25°C to 65°C
Degree of protection IP40
Electric shock protection class Class II
PTI (proof tracking index) 175
Pollution degree 3 (IEC947-5-1)