Protection type : Shut down o/p voltage, re-power on to recover
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5 ~ 95% RH non-condensing
-40 ~ +85 , 5 ~ 95% RH℃
± ℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
223.2K hrs min. MIL-HDBK-217F (25 )℃
189*77*36mm (L*W*H)
0.8Kg; 15pcs/13Kg/0.75CUFT
File Name:RSD-150-SPEC 2014-10-08
150W Railway Single Output DC-DC Converter
■ Features :
RSD-150 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
SAFETY &
EMC
(Note 4)
ENVIRONMENT
PROTECTION
1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Strongly recommended that external output capacitance should not exceed 5000uF.
5V 12V 24V 5V 12V 24V 5V 12V 24V
30A 12.5A 6.3A 30A 12.5A 6.3A 30A 12.5A 6.3A
0 ~ 30A 0 ~ 12.5A 0 ~ 6.3A 0 ~ 30A 0 ~ 12.5A 0 ~ 6.3A 0 ~ 30A 0 ~ 12.5A 0 ~ 6.3A
150W 150W 151.2W 150W 150W 151.2W 150W 150W 151.2W
100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p
±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
±0.5% ±0.3% ±0.2% ±0.5% ±0.3% ±0.2% ±0.5% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
800ms, 50ms at full load
89%
7.3A/24V
90% 90% 90% 92% 91% 90% 92% 91%
7.3A/24V 7.3A/24V 3.6A/48V
45A/48VDC
3.6A/48V 3.6A/48V 1.5A/110V
45A/110VDC
1.5A/110V 1.5A/110V
45A/24VDC
Meet IEC60950-1(LVD)
‧Compliance to EN50155 and EN45545-2 railway standard
‧2:1 wide input range
‧Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input reverse polarity
‧4000VDC I/O isolation
‧Cooling by free air convection
‧Half encapsulated
‧Built-in constant current limiting circuit
‧1U low profile 36mm
‧All using 105 long life electrolytic capacitors℃
‧LED indicator for power on
‧100% full load burn-in test
‧3 years warranty
5.75 ~ 7V 5.75 ~ 7V 5.75 ~ 7V13.8 ~ 16.2V 13.8 ~ 16.2V 13.8 ~ 16.2V27.6 ~ 32.4V 27.6 ~ 32.4V 27.6 ~ 32.4V
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
EMC IMMUNITY
EMC EMISSION
HOLD UP TIME (Typ.)
B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load (except RSD-150B-5 @ 60% load) ; D-type comply with S2 level @ full load
VOLTAGE
RANGE
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
67.2 ~ 143VDC
57.6 ~ 154VDC
CONTINUOUS
1 SEC.
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
RAILWAY STANDARD Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC ; EN45545-2 for fire protection
RSD-150B-5
RSD-150B-12 RSD-150C-12 RSD-150D-12
RSD-150B-24 RSD-150C-24
RSD-150D-24
RSD-150C-5 RSD-150D-5
-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance℃ ℃ ℃