Auto Off
45 min
LO M
+
+
Do not
overtighten
screw
OFF
2 AA
+
+
WWarning
• Disconnect test leads from power source
before opening battery door.
• Débranchez les cordons d'essai avant
d'ouvrir le couvercle de la pile.
• Prima di aprire lo sportello del vano della pila,
scollegare i cavetti dal circuito di
alimentazione.
• Die Prüfleiter vor dem Öffnen des
Batteriefachs von der Stromquelle trennen.
• Desconecte los conductores de prueba de la
fuente de alimentación antes de abrir la
cubierta de la batería.
• Antes de abrir a tampa do compartimento das
pilhas, desconecte os terminais de teste da
fonte de alimentação.
• Maak de meetkabels los van de stroombron
voordat u de batterijklep opent.
• Koble prøveledningene fra strømkilden før
batteridekselet åpnes.
• Søgeledningerne skal tages evt. emne, inden
batteridækslet åbnes.
• Irrota koestusjohtimet virtalähteestä ennen
paristolokeron avaamista.
• Koppla bort mätsladdarna från strömkällan
innan du öppnar batteriluckan.
•
•
•
•
•
Specifications
Specifications subject to change without notice.
Calibration 1-year calibration cycle
Temperature
Operating:
Storage: -10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating:
Storage: 2000 m (6562 ft)
10,000 m (328 08 ft)
Relative
Humidity 0 % to 95 %, 5 °C to 30 °C
(41 °F to 86 °F); 0 % to 75 %,
30 °C to 40 °C
(86 °F to 104 °F); 0 % to 45 %,
40 °C to 50 °C
(104 °F to 12 2 °F)
Batter y Ty pe
and Lif e AA (2); 360 hours continuous with
alkaline; 125 hours continuous with
zinc chloride
RF Field
Specification 0.5 % full scale + (specified accuracy)
at 3 V / m
Enclosure
Rating IP 52 per IEC 60529, no vacuum
applied
Safety Complies with ANSI/ISA-S82.01-94,
UL classified to IEC 61010, CSA/CAN
C22.2 No.1010.1-92, and EN 61010-
1: 1995.
EMC EN 61326
Temperature
coefficient 0.1 x (specified accuracy) / °C for <18
°C or >28 °C (< 64.4 °F or > 82.4 °F)
Accuracy ± ( [ % of reading] + [number of least
significant digits] )
Accuracy is specified for 1 year after
calibratio n, at 18 °C to 28 °C
(64 °F to 82 °F) with relative hu midi ty
to 90 %. AC conversions are ac-
coupled, average responding, and
calibrated to the rms value of a sine
wave input.
CAT III protects against transients in a fixed eq uip men t
installation such as a distribution panel, and lighti ng
systems in large buildings.
CAT IV protects against transients from a pri mary su ppl y
such as an electric ity mete r or an ove rhe ad or
underground utility service.
Function T5-600
Range
T5-1000
Range
Reso-
lution
Accuracy
K
600 V
rms 1000 V
rms 1 V ± (1.5 % + 2
digits)
L
600 V 1000 V 1 V ± (1 % + 1 digit)
100.0 A 100.0 A
?
1000 V CAT III
600 V CAT IV
0.1 A ± (3 % + 3 digits)
e
1000 Ω1000 Ω1 Ω± (1 % + 2 digits)
Certifications: P$In accordance with
IEC 61010-1, 54CJ
Replacement Parts
Test Lead Assembly.
Replace onl y with Fl u ke do ubl e -insula ted
leads (
T
) See "Accessories" for available
probes.
PN 648029
Battery Door PN 1626588
Battery Door Screw PN 1618578
Accessories
H5 Belt Holster
TP1 Probe Set, Flat-Blade
AC285 SureGrip™ Alligator Clips
AC220 SureGrip™ Alligator Clips
Service Information Sheet, PN 686953