1
High Density - Board Mounted Power Division
Powering Communications and Technology
IES020YG-A
40
45
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFF. (18v)
EFF. (24v)
EFF. (36v)
Efficiency vs. Load (48V Input)
20W Standard Package
100°C Case Operation
• 3.3V Output Available
• Open Frame or
Encapsulated
88% Efficiency at 5V
Wide Range Input
1500V Isolation
Short Circuit
Protection
DESCRIPTION
FEATURES
Efficiency vs. Load (24V Input)
IES SERIES
20 WATT
IES DC/DC converters provide up to 20 Watts of
output power in an industry standard package. With
88% efficiency and a maximum case temperature of
100°C, the IES is well suited for the most demanding
telecom, networking, and industrial applications.
The IES features 1500 VDC isolation, short circuit,
and overtemperature protection.
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
Turn-On Time 10 ms
Remote Shutdown Positive Logic
Switching Frequency 300 kHz Open Frame / 450 kHz Cased
Isolation
Input - Output 1500 VDC
Input - Case (24 Vin Units) 500 VDC
Output - Case (48 Vin Units) 500 VDC
Temperature Coefficient 0.03%/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF(Bellcore TR-NWT-000332) 1.9 x 106hrs
Safety UL, CSA, EN60950
Weight (approx.) 1.2 oz
General
Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., Iout Rated 0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. 0.5% Vout
Minimum Output Current 10 %
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 µs
Voltage Trim Range ±10%
Short Circuit / Overcurrent Protection Shutdown / Hiccup
Current Limit Threshold Range, % of Iout Rated 110 - 140%
OVP Trip Range 115 - 140% Vout Nom.
OVP Type Second Control Loop, Self-Recovering
TECHNICAL SPECIFICATIONS
Voltage Range
24 VDC Nominal 16 - 36 VDC
48 VDC Nominal 36 - 72 VDC
Input Undervoltage Lockout <34V or <17V
UVLO Hysteresis 1V Nom.
Reflected Ripple 25 mA
Input Reverse Voltage Protection Shunt Diode
IES020ZG-A
40
45
50
55
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFF. (36v)
EFF. (48v)
EFF. (72v)
Output
Input
2
MECHANICAL DRAWING
Thermal Impedance Tolerances
IES SERIES
20 WATT
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
Case:
+ 0.04, - 0.00 + 1.0, - 0.00
(Dimensions as listed unless
otherwise specified.)
Note:
Thermal impedance data is dependent on many
environmental factors. The exact thermal performance
should be validated for specific application.
Encapsulated Open Frame
Modules Modules
Natural Convection 15.4 °C/W 14.9 °C/W
100 LFM 12.2 °C/W 11.3 °C/W
200 LFM 9.3 °C/W 8.3 °C/W
300 LFM 7.4 °C/W 6.8 °C/W
400 LFM 6.4 °C/W 5.4 °C/W
Pin Function
1+V
in
2-V
in
3 No Pin
4 Shutdown
5+V
out
6-V
out
7 Trim
8 No Pin
9 No Pin
MODELS - (See the last page of Section for options.)
trahCnoitceleS
ledoM niV
)stloV(
egnaRniV
)stloV(
*.xaMniI
)spmA(
tuoV
)stloV(
detaRtuoI
)spmA(
esioN&elppiR
)Vm(kP-kP
ycneiciffE
**.pyT
A-GY020SEI
A-EZ310SEI
A-GZ020SEI
42
84
84
63-61
27-63
27-63
32.1
54.0
56.0
0.5
3.3
0.5
0.4
0.4
0.4
57
051
57
%78
%38
%78
.rewoptuptuodetarmumixam,egatlovtupnimuminimtatnerructupnimumixaM*
.tuptuodetar,niVlanimontA**
High Density - Board Mounted Power Division
Powering Communications and Technology
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and
add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used
in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manu-
factured. Specifications are subject to change without notice.
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180"
(4.6mm)
0.24" (6.1mm) Horizontal Heatsink 1H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink 2H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink 3H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
High Density - Board Mounted Power Division
Powering Communications and Technology
3