3
G2R G2R
Specifications
■CONTACT DATA
Non-latching general purpose, plug-in, plug-in operation indicator self-contained, plug-in diode self-contained, and
upper-mount bracket
1-pole type 2-pole type
Resistive load Inductiv e load Resistive load Inductive load
Load (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms) (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms)
Rated load 10 A at 250 VAC 7.5 A at 250 VA C 5 A at 250 VA C 2 A at 250 VA C
10 A at 30 VDC 5 A at 30 VDC 5 A at 30 VDC 3 A at 30 VDC
Contact material AgCdO
Carry current 10 A 5 A
Max. operating voltage 380 VAC , 125 VDC
Max. operating current 10 A 5 A
Max. s witching capacity 2,500 VA, 300 W 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W
Min. permissible load 100 mA, 5 VDC 10 mA, 5 VDC
Non-latching high capacity
1-pole type
Resistive load Inductiv e load
Load (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms)
Rated load 16 A at 250 VAC 8 A at 250 VA C
16 A at 30 VDC 8 A at 30 VDC
Contact material AgCdO
Carry current 16 A
Max. operating voltage 380 VAC , 125 VDC
Max. operating current 16 A
Max. s witching capacity 4,000 VA, 480 W 2,000 VA, 240 W
Min. permissible load 100 mA, 5 VDC
1-pole type 2-pole type
Resistive load Inductiv e load Resistive load Inductive load
Load (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms) (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms)
Rated load 5 A at 250 VA C 2 A at 250 VAC 3 A at 250 VA C 1 A at 250 VAC
5 A at 30 VDC 3 A at 30 VDC 3 A at 30 VDC 1.50 A at 30 VDC
Contact material AgCdO
Carry current 5A 3 A
Max. operating voltage 380 VAC , 125 VDC
Max. operating current 5 A 3 A
Max. switching capacity 1,250 VA, 150 W 500 V A, 90 W 750 V A, 90 W 250 V A, 45 W
Min. permissible load 100 mA, 5 VDC 10 mA, 5 VDC
Non-latching high-sensitivity
1-pole type 2-pole type
Resistive load Inductiv e load Resistive load Inductive load
Load (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms) (p.f. = 1) (p.f. = 0.4) (L/R = 7 ms)
Rated load 5 A at 250 VA C 3.50 A at 250 VA C 3 A at 250 VA C 1.50 A at 250 VA C
5 A at 30 VDC 2.50 A at 30 VDC 3 A at 30 VDC 2 A at 30 VDC
Contact material AgCdO
Carry current 5A 3 A
Max. operating voltage 380 VAC , 125 VDC
Max. operating current 5 A 3 A
Max. switching capacity 1,250 VA, 150 W 875 V A, 75 W 750 V A, 90 W 375 V A, 60 W
Min. permissible load 100 mA, 5 VDC 10 mA, 5 VDC
Latching
Note: 1. P standard: λ50 = 0.10 x 10-6 operation.
2. AgInSn contacts available.
3. For individual product agency approvals consult factor y.