145
G2RG2R
PCB/Fully sealed Relays
Note: P level: l60 = 0.1 x 10–6/operation
Latching Relays
Note: P level: l60 = 0.1 x 10-6/operation
■Characteristics
Standard Relays
Note: Values in the above table are t he initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Item General-purpose (single contact) Bifurcated contact
Number of poles 1 pole 2 poles 1 pole
Load Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Resistive load
(cos
f
= 1) Inducti ve load
(cos
f
= 0.4;
L/R = 7 ms)
Rated load 8 A at 250 VA C;
8 A at 30 VDC 6 A at 250 VAC;
4 A at 30 VDC 4 A at 250 VAC;
4 A at 30 VDC 1.5 A at 250 VAC;
2.5 A at 30 VDC 5 A at 250 VAC;
5 A at 30 VDC 2 A at 250 VAC;
3 A at 30 VDC
Rated carry current 8 A 4 A 5 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 8 A 4 A 5 A
Max. switching power 2,000 VA ,
240 W 1,500 VA,
120 W 1,000 VA ,
120 W 375 VA,
75 W 1,250 VA,
150 W 500 VA,
90 W
Fail ur e r a t e
(reference value) 100 mA at 5 VDC 10 mA at 5 VDC 1 mA at 5 VDC
Number of poles 1 pole 2 poles
Load Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4;
L/R = 7 ms)
Rated load 5 A at 250 VAC;
5 A at 30 VDC 3.5 A at 250 VAC;
2.5 A at 30 VDC 3 A at 250 VAC;
3 A at 30 VDC 1.5 A at 250 VAC;
2 A at 30 VDC
Rated carry current 5 A 3 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 5 A 3 A
Max. switching power 1,250 VA, 150 W 875 VA, 75 W 750 VA, 90 W 375 VA, 60 W
Fail ur e r a t e
(reference value) 100 mA at 5 VDC 10 mA at 5 VDC
Item 1 pole 2 poles
Contact resistance 30 m
W
max. (high-capacity type: 100 m
W
max.) 50 m
W
max.
Operate (set) time 15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 M
W
min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100m/s2 when no energized
Endurance Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100, 000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature Operating:
-
40°C to 70°C (with no ic ing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 17 g (plug-in terminal: approx. 20 g)