Amphenol 47
C 091
IP Codes
(Ingress Protection)
Degree of protection
Electrical devices to which connectors belong have to be protected for safety reasons from outside influences like dust, foreign objects, direct contact, moisture
and water. This protection is provided on industrial connectors by their housings with their latching devices and sealed cable entries.
The degree of protection can be selected depending on the type of intended use. The standard IEC 60529 and/or DIN EN 60529 has specified the degree of
protection and divided into several classes.
The degree of protection is indicated in the following way:
IP 65
Code letters
(Ingress Protection)
1st charact. numeral (degree of protection against access
to hazardous parts and against solid foreign objects)
2nd charact. numeral (degree of protection against ingress of water)
The following charts give an overview about all protection degrees.
1st charact. Brief description Definition
numeral
0
1
2
3
4
5
6
Non-protected
Protected against access to
hazardous parts with the
back of a hand. Protected
against solid foreign objects
of ≥50mm Ø
.
Protected against access to
hazardous parts with a
finger.
Protected against solid
foreign objects of
≥12.5mm Ø
.
Protected against access
to hazardous parts with a
tool. Protected against solid
foreign objects of ≥2.5mm
Ø
.
Protected against access to
hazardous parts with a
wire.Protected against solid
foreign objects of ≥1mm Ø
.
Protected against access to
hazardous parts with a wire.
Dust-protected.
Protected against access to
hazardous parts with a wire.
Dust-tight.
–
The probe, sphere of 50mm
Ø, shall not fully penetrate
and shall have adequate
clearance from hazardous
parts.
The jointed test finger of
12mm Ø, 80mm length,
shall have adequate clearance
from hazardous parts. The
probe, sphere of 12.5mm Ø,
shall not fully penetrate.
The probe of 2.5mm Øshall
not penetrate at all.
The probe of 1mm Øshall
not penetrate at all.
The probe of 1mm Øshall
not penetrate.
Intrusion of dust is not
totally prevented, but dust
shall not penetrate in a
quantity to interfere with
satisfactory operation of
the device or to impair
safety.
The probe of 1mm Øshall
not penetrate.
No intrussion of dust.
1) Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code
2nd charact. Brief description Definition
numeral
0
1
2
3
4
5
6
7
8
9 K
1)
Non-protected
Protected against vertically
falling water drops
Protected against vertically
falling water drops when
enclosure tilted up to 15°
Protected against spraying
water
Protected against splashing
water
Protected against water jets
Protected against powerful
water jets
Protected against the effects
of temporary immersion in
water
Protected against the effects
of continous immersion in
water
Protected against water
during high pressure/steam
jet cleaning
–
Vertically falling drops shall
have no harmful effects.
Vertically falling drops shall
have no harmful effects when
the enclosure is tilted at any
angle up to 15° on either side
of the vertical.
Water sprayed at an angle up
to 60° on either side of the
vertical shall have no harmful
effects.
Water splashed against the
enclosure from any direction
shall have no harmful effects.
Water projected in jets against
the enclosure from any
direction shall have no harmful
effects.
Water projected in powerful
jets against the enclosure
from any direction shall have
no harmful effects.
Intrusion of water in quantities
causing harmful effects shall
not be possible when the
enclosure is temporally
immersed in water for 30 min.
in 1m depth.
Intrusion of water in quantities
causing harmful effects shall
not be possible when the
enclosure is continuously
immersed in water under
conditions which shall be
agreed between manufacturer
and user but which are more
severe than for numeral 7.
Water projected in powerful
jets with high pressure against
the enclosure from any
direction shall have no harmful