M29F200BT M29F200BB 2 Mbit (256Kb x8 or 128Kb x16, Boot Block) Single Supply Flash Memory Features Single 5V10% supply voltage for Program, Erase and Read operations Access time: 45, 50, 70, 90ns Programming time - 8s per Byte/Word typical 7 memory blocks - 1 Boot Block (Top or Bottom location) - 2 parameter and 4 main blocks Program/Erase controller - Embedded Byte/Word Program algorithm - Embedded Multi-Block/Chip Erase algorithm - Status Register polling and toggle bits - Ready/Busy output pin TSOP48 (N) 12 x 20mm 44 Erase Suspend and Resume modes - Read and Program another block during Erase Suspend Unlock Bypass Program command - Faster Production/Batch Programming Temporary Block Unprotection mode Low power consumption - Standby and Automatic Standby 100,000 Program/Erase cycles per block 20 years data retention - Defectivity below 1 ppm/year Electronic Signature - Manufacturer code: 0020h - Top Device code M29F200BT: 00D3h - Bottom Device code: M29F200BB: 00D4h ECOPACK(R) packages available March 2007 1 SO44 (M) Rev 5 1/39 www.st.com 1 Contents M29F200BT, M29F200BB Contents 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3 4 2/39 2.1 Address Inputs (A0-A16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.2 Data Inputs/Outputs (DQ0-DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Data Inputs/Outputs (DQ8-DQ14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.4 Data Input/Output or Address Input (DQ15A-1) . . . . . . . . . . . . . . . . . . . . 10 2.5 Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.6 Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.7 Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.8 Reset/Block Temporary Unprotect (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.9 Ready/Busy Output (RB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.10 Byte/Word Organization Select (BYTE) . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.11 VCC Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.12 Vss Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.3 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.4 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.5 Automatic Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.6 Special Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.6.1 Electronic Signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.6.2 Block Protection and Blocks Unprotection . . . . . . . . . . . . . . . . . . . . . . . 14 Command interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.0.1 Read/Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.0.2 Auto Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.0.3 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.0.4 Unlock Bypass command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.0.5 Unlock Bypass Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 M29F200BT, M29F200BB 5 Contents 4.0.6 Unlock Bypass Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.0.7 Chip Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.0.8 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4.0.9 Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4.0.10 Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Status register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.1 Data Polling Bit (DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.2 Toggle Bit (DQ6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.3 Error Bit (DQ5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.4 Erase Timer Bit (DQ3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.5 Alternative Toggle Bit (DQ2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 6 Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 7 DC and ac parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 8 Package Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 9 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Appendix A Block addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 10 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 3/39 List of tables M29F200BT, M29F200BB List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. 4/39 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Bus operations, BYTE = VIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Bus operations, BYTE = VIH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Commands, 16-bit mode, BYTE = VIH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Commands, 8-bit mode, BYTE = VIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Program, Erase times and Program, Erase endurance cycles (TA = 0 to 70C, -40 to 85C or -40 to 125C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Status Register Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Operating and ac measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Capacitance (TA = 25 C, f = 1 MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 DC characteristics (TA = 0 to 70C, -40 to 85C or -40 to 125C). . . . . . . . . . . . . . . . . . . 29 Read ac characteristics (TA = 0 to 70C, -40 to 85C or -40 to 125C) . . . . . . . . . . . . . . 30 Write ac characteristics, Write Enable controlled (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Write AC Characteristics, Chip Enable Controlled (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Reset/Block Temporary Unprotect AC Characteristics (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 TSOP48 - 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Mechanical Data . . . 34 SO44 - 44 lead Plastic Small Outline, 500 mils body width, package mechanical data . . . 35 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Top Boot block addresses, M29F200BT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Bottom Boot Block Addresses, M29F200BB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 M29F200BT, M29F200BB List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SO connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 TSOP connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Data polling flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Data toggle flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 AC testing input output waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 AC testing load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Read Mode ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Write ac waveforms, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Write ac waveforms, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Reset/Block Temporary Unprotect ac waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 TSOP48 - 48 lead Plastic Thin Small Outline, 12 x 20mm, package outline . . . . . . . . . . . 34 SO44 - 44 lead Plastic Small Outline, 500 mils body width, package outline . . . . . . . . . . . 35 5/39 Description 1 M29F200BT, M29F200BB Description The M29F200B is a 2 Mbit (256Kb x8 or 128Kb x16) non-volatile memory that can be read, erased and reprogrammed. These operations can be performed using a single 5V supply. On power-up the memory defaults to its Read mode where it can be read in the same way as a ROM or EPROM. The M29F200B is fully backward compatible with the M29F200. The memory is divided into blocks that can be erased independently so it is possible to preserve valid data while old data is erased. Each block can be protected independently to prevent accidental Program or Erase commands from modifying the memory. Program and Erase commands are written to the Command Interface of the memory. An on-chip Program/Erase Controller simplifies the process of programming or erasing the memory by taking care of all of the special operations that are required to update the memory contents. The end of a program or erase operation can be detected and any error conditions identified. The command set required to control the memory is consistent with JEDEC standards. The blocks in the memory are asymmetrically arranged, see Table 19 and Table 20, Block Addresses. The first or last 64 KBytes have been divided into four additional blocks. The 16 KByte Boot Block can be used for small initialization code to start the microprocessor, the two 8 KByte Parameter Blocks can be used for parameter storage and the remaining 32K is a small Main Block where the application may be stored. Chip Enable, Output Enable and Write Enable signals control the bus operation of the memory. They allow simple connection to most microprocessors, often without additional logic. The memory is offered in TSOP48 (12 x 20mm) and SO44 packages and it is supplied with all the bits erased (set to '1'). In order to meet environmental requirements, ST offers the M29F200B in ECOPACK(R) packages. ECOPACK packages are Lead-free. The category of second Level Interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. ECOPACK is an ST trademark. ECOPACK specifications are available at: www.st.com. 6/39 M29F200BT, M29F200BB Table 1. Description Signal names Name Description A0-A16 Direction Address Inputs Inputs DQ0-DQ7 Data Inputs/Outputs Input/Outputs DQ8-DQ14 Data Inputs/Outputs Input/Outputs Data Input/Output or Address Input Input/Output DQ15A-1 E Chip Enable Input G Output Enable Input W Write Enable Input RP Reset/Block Temporary Unprotect Input RB Ready/Busy Output BYTE Output Byte/Word Organization Select Input VCC Supply Voltage VSS Ground - NC Not Connected Internally - Figure 1. Supply Logic diagram VCC 17 15 A0-A16 DQ0-DQ14 DQ15A-1 W E M29F200BT M29F200BB G BYTE RB RP VSS AI02912 7/39 Description M29F200BT, M29F200BB Figure 2. SO connections NC RB NC A7 A6 A5 A4 A3 A2 A1 A0 E VSS G DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 1 44 2 43 3 42 4 41 5 40 6 39 7 38 8 37 9 36 10 35 11 M29F200BT 34 12 M29F200BB 33 13 32 14 31 15 30 16 29 28 17 27 18 26 19 25 20 21 24 22 23 AI02914 8/39 RP W A8 A9 A10 A11 A12 A13 A14 A15 A16 BYTE VSS DQ15A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC M29F200BT, M29F200BB Figure 3. Description TSOP connections A15 A14 A13 A12 A11 A10 A9 A8 NC NC W RP NC NC RB NC NC A7 A6 A5 A4 A3 A2 A1 1 12 13 24 48 M29F200BT M29F200BB 37 36 25 A16 BYTE VSS DQ15A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 G VSS E A0 AI02913 9/39 Signal descriptions 2 M29F200BT, M29F200BB Signal descriptions See Figure 1: Logic diagram, and Table 1: Signal names, for a brief overview of the signals connected to this device. 2.1 Address Inputs (A0-A16) The Address Inputs select the cells in the memory array to access during Bus Read operations. During Bus Write operations they control the commands sent to the Command Interface of the internal state machine. 2.2 Data Inputs/Outputs (DQ0-DQ7) The Data Inputs/Outputs output the data stored at the selected address during a Bus Read operation. During Bus Write operations they represent the commands sent to the Command Interface of the internal state machine. 2.3 Data Inputs/Outputs (DQ8-DQ14) The Data Inputs/Outputs output the data stored at the selected address during a Bus Read operation when BYTE is High, VIH. When BYTE is Low, VIL, these pins are not used and are high impedance. During Bus Write operations the Command Register does not use these bits. When reading the Status Register these bits should be ignored. 2.4 Data Input/Output or Address Input (DQ15A-1) When BYTE is High, VIH, this pin behaves as a Data Input/Output pin (as DQ8-DQ14). When BYTE is Low, VIL, this pin behaves as an address pin; DQ15A-1 Low will select the LSB of the Word on the other addresses, DQ15A-1 High will select the MSB. Throughout the text consider references to the Data Input/Output to include this pin when BYTE is High and references to the Address Inputs to include this pin when BYTE is Low except when stated explicitly otherwise. 2.5 Chip Enable (E) The Chip Enable, E, activates the memory, allowing Bus Read and Bus Write operations to be performed. When Chip Enable is High, VIH, all other pins are ignored. 2.6 Output Enable (G) The Output Enable, G, controls the Bus Read operation of the memory. 10/39 M29F200BT, M29F200BB 2.7 Signal descriptions Write Enable (W) The Write Enable, W, controls the Bus Write operation of the memory's Command Interface. 2.8 Reset/Block Temporary Unprotect (RP) The Reset/Block Temporary Unprotect pin can be used to apply a Hardware Reset to the memory or to temporarily unprotect all Blocks that have been protected. A Hardware Reset is achieved by holding Reset/Block Temporary Unprotect Low, VIL, for at least tPLPX. After Reset/Block temporary unprotect goes High, VIH, the memory will be ready for Bus Read and Bus Write operations after tPHEL or tRHEL, whichever occurs last. See the Ready/Busy Output section, Table 15: Reset/Block Temporary Unprotect AC Characteristics (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) and Figure 11: Reset/Block Temporary Unprotect ac waveforms, for more details. Holding RP at VID will temporarily unprotect the protected Blocks in the memory. Program and Erase operations on all blocks will be possible. The transition from VIH to VID must be slower than tPHPHH. 2.9 Ready/Busy Output (RB) The Ready/Busy pin is an open-drain output that can be used to identify when the memory array can be read. Ready/Busy is high-impedance during Read mode, Auto Select mode and Erase Suspend mode. After a Hardware Reset, Bus Read and Bus Write operations cannot begin until Ready/Busy becomes high-impedance. See Table 15: Reset/Block Temporary Unprotect AC Characteristics (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) and Figure 11: Reset/Block Temporary Unprotect ac waveforms. During Program or Erase operations Ready/Busy is Low, VOL. Ready/Busy will remain Low during Read/Reset commands or Hardware Resets until the memory is ready to enter Read mode. The use of an open-drain output allows the Ready/Busy pins from several memories to be connected to a single pull-up resistor. A Low will then indicate that one, or more, of the memories is busy. 2.10 Byte/Word Organization Select (BYTE) The Byte/Word Organization Select pin is used to switch between the 8-bit and 16-bit Bus modes of the memory. When Byte/Word Organization Select is Low, VIL, the memory is in 8bit mode, when it is High, VIH, the memory is in 16-bit mode. 2.11 VCC Supply Voltage The VCC Supply Voltage supplies the power for all operations (Read, Program, Erase etc.). The Command Interface is disabled when the VCC Supply Voltage is less than the Lockout Voltage, VLKO. This prevents Bus Write operations from accidentally damaging the data during power up, power down and power surges. If the Program/Erase Controller is 11/39 Signal descriptions M29F200BT, M29F200BB programming or erasing during this time then the operation aborts and the memory contents being altered will be invalid. A 0.1F capacitor should be connected between the VCC Supply Voltage pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB track widths must be sufficient to carry the currents required during program and erase operations, ICC4. 2.12 Vss Ground The VSS Ground is the reference for all voltage measurements. 12/39 M29F200BT, M29F200BB 3 Bus operations Bus operations There are five standard bus operations that control the device. These are Bus Read, Bus Write, Output Disable, Standby and Automatic Standby. See Table 2 and Table 3, Bus Operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect bus operations. 3.1 Bus Read Bus Read operations read from the memory cells, or specific registers in the Command Interface. A valid Bus Read operation involves setting the desired address on the Address Inputs, applying a Low signal, VIL, to Chip Enable and Output Enable and keeping Write Enable High, VIH. The Data Inputs/Outputs will output the value, see Figure 8: Read Mode ac waveforms, and Table 12: Read ac characteristics (TA = 0 to 70C, -40 to 85C or -40 to 125C), for details of when the output becomes valid. 3.2 Bus Write Bus Write operations write to the Command Interface. A valid Bus Write operation begins by setting the desired address on the Address Inputs. The Address Inputs are latched by the Command Interface on the falling edge of Chip Enable or Write Enable, whichever occurs last. The Data Inputs/Outputs are latched by the Command Interface on the rising edge of Chip Enable or Write Enable, whichever occurs first. Output Enable must remain High, VIH, during the whole Bus Write operation. See Figure 9 and Figure 10, Write ac waveforms, and Table 13 and Table 14, Write ac characteristics, for details of the timing requirements. 3.3 Output Disable The Data Inputs/Outputs are in the high impedance state when Output Enable is High, VIH. 3.4 Standby When Chip Enable is High, VIH, the Data Inputs/Outputs pins are placed in the highimpedance state and the Supply Current is reduced to the Standby level. When Chip Enable is at VIH the Supply Current is reduced to the TTL Standby Supply Current, ICC2. To further reduce the Supply Current to the CMOS Standby Supply Current, ICC3, Chip Enable should be held within VCC 0.2V. For Standby current levels see Table 11: DC characteristics (TA = 0 to 70C, -40 to 85C or -40 to 125C). During program or erase operations the memory will continue to use the Program/Erase Supply Current, ICC4, for Program or Erase operations until the operation completes. 13/39 Bus operations 3.5 M29F200BT, M29F200BB Automatic Standby If CMOS levels (VCC 0.2V) are used to drive the bus and the bus is inactive for 150ns or more the memory enters Automatic Standby where the internal Supply Current is reduced to the CMOS Standby Supply Current, ICC3. The Data Inputs/Outputs will still output data if a Bus Read operation is in progress. 3.6 Special Bus operations Additional bus operations can be performed to read the Electronic Signature and also to apply and remove Block Protection. These bus operations are intended for use by programming equipment and are not usually used in applications. They require VID to be applied to some pins. 3.6.1 Electronic Signature The memory has two codes, the manufacturer code and the device code, that can be read to identify the memory. These codes can be read by applying the signals listed in Table 2 and Table 3, Bus operations. 3.6.2 Block Protection and Blocks Unprotection Each block can be separately protected against accidental Program or Erase. Protected blocks can be unprotected to allow data to be changed. There are two methods available for protecting and unprotecting the blocks, one for use on programming equipment and the other for in-system use. For further information refer to Application Note AN1122, Applying Protection and Unprotection to M29 Series Flash. Table 2. Bus operations, BYTE = VIL(1) Data Inputs/Outputs Operation G W DQ14DQ8 DQ7-DQ0 Bus Read VIL VIL VIH Cell Address Hi-Z Data Output Bus Write VIL VIH VIL Command Address Hi-Z Data Input X VIH VIH X Hi-Z Hi-Z Standby VIH X X X Hi-Z Hi-Z Read Manufacturer Code VIL VIL VIH A0 = VIL, A1 = VIL, A9 = VID, Others VIL or VIH Hi-Z 20h VIH A0 = VIH, A1 = VIL, A9 = VID, Others VIL or VIH Hi-Z D3h (M29F200BT) D4h (M29F200BB) Output Disable Read Device Code 1. X = VIL or VIH. 14/39 E Address Inputs DQ15A-1, A0-A16 VIL VIL M29F200BT, M29F200BB Table 3. Bus operations Bus operations, BYTE = VIH(1) Operation Address Inputs A0-A16 Data Inputs/Outputs DQ15A-1, DQ14-DQ0 E G W Bus Read VIL VIL VIH Cell Address Bus Write VIL VIH VIL Command Address X VIH VIH X Hi-Z Standby VIH X X X Hi-Z Read Manufacturer Code VIL VIL VIH A0 = VIL, A1 = VIL, A9 = VID, Others VIL or VIH 0020h Read Device Code VIL VIL VIH A0 = VIH, A1 = VIL, A9 = VID, Others VIL or VIH 00D3h (M29F200BT) 00D4h (M29F200BB) Output Disable Data Output Data Input 1. X = VIL or VIH. 15/39 Command interface 4 M29F200BT, M29F200BB Command interface All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. Failure to observe a valid sequence of Bus Write operations will result in the memory returning to Read mode. The long command sequences are imposed to maximize data security. The address used for the commands changes depending on whether the memory is in 16bit or 8-bit mode. See either Table 4, or Table 5, depending on the configuration that is being used, for a summary of the commands. 4.0.1 Read/Reset command The Read/Reset command returns the memory to its Read mode where it behaves like a ROM or EPROM. It also resets the errors in the Status Register. Either one or three Bus Write operations can be used to issue the Read/Reset command. If the Read/Reset command is issued during a Block Erase operation or following a Programming or Erase error then the memory will take up to 10s to abort. During the abort period no valid data can be read from the memory. Issuing a Read/Reset command during a Block Erase operation will leave invalid data in the memory. 4.0.2 Auto Select command The Auto Select command is used to read the Manufacturer Code, the Device Code and the Block Protection Status. Three consecutive Bus Write operations are required to issue the Auto Select command. Once the Auto Select command is issued the memory remains in Auto Select mode until another command is issued. From the Auto Select mode the Manufacturer Code can be read using a Bus Read operation with A0 = VIL and A1 = VIL. The other address bits may be set to either VIL or VIH. The Manufacturer Code for STMicroelectronics is 0020h. The Device Code can be read using a Bus Read operation with A0 = VIH and A1 = VIL. The other address bits may be set to either VIL or VIH. The Device Code for the M29F200BT is 00D3h and for the M29F200BB is 00D4h. The Block Protection Status of each block can be read using a Bus Read operation with A0 = VIL, A1 = VIH, and A12-A16 specifying the address of the block. The other address bits may be set to either VIL or VIH. If the addressed block is protected then 01h is output on Data Inputs/Outputs DQ0-DQ7, otherwise 00h is output. 4.0.3 Program command The Program command can be used to program a value to one address in the memory array at a time. The command requires four Bus Write operations, the final write operation latches the address and data in the internal state machine and starts the Program/Erase Controller. If the address falls in a protected block then the Program command is ignored, the data remains unchanged. The Status Register is never read and no error condition is given. During the program operation the memory will ignore all commands. It is not possible to issue any command to abort or pause the operation. Typical program times are given in Table 6. Bus Read operations during the program operation will output the Status Register on the Data Inputs/Outputs. See the section on the Status Register for more details. 16/39 M29F200BT, M29F200BB Command interface After the program operation has completed the memory will return to the Read mode, unless an error has occurred. When an error occurs the memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode. Note that the Program command cannot change a bit set at '0' back to '1'. One of the Erase Commands must be used to set all the bits in a block or in the whole memory from '0' to '1'. 4.0.4 Unlock Bypass command The Unlock Bypass command is used in conjunction with the Unlock Bypass Program command to program the memory. When the access time to the device is long (as with some EPROM programmers) considerable time saving can be made by using these commands. Three Bus Write operations are required to issue the Unlock Bypass command. Once the Unlock Bypass command has been issued the memory will only accept the Unlock Bypass Program command and the Unlock Bypass Reset command. The memory can be read as if in Read mode. 4.0.5 Unlock Bypass Program command The Unlock Bypass Program command can be used to program one address in memory at a time. The command requires two Bus Write operations, the final write operation latches the address and data in the internal state machine and starts the Program/Erase Controller. The Program operation using the Unlock Bypass Program command behaves identically to the Program operation using the Program command. A protected block cannot be programmed; the operation cannot be aborted and the Status Register is read. Errors must be reset using the Read/Reset command, which leaves the device in Unlock Bypass Mode. See the Program command for details on the behavior. 4.0.6 Unlock Bypass Reset command The Unlock Bypass Reset command can be used to return to Read/Reset mode from Unlock Bypass Mode. Two Bus Write operations are required to issue the Unlock Bypass Reset command. 4.0.7 Chip Erase command The Chip Erase command can be used to erase the entire chip. Six Bus Write operations are required to issue the Chip Erase Command and start the Program/Erase Controller. If any blocks are protected then these are ignored and all the other blocks are erased. If all of the blocks are protected the Chip Erase operation appears to start but will terminate within about 100s, leaving the data unchanged. No error condition is given when protected blocks are ignored. During the erase operation the memory will ignore all commands. It is not possible to issue any command to abort the operation. Typical chip erase times are given in Table 6. All Bus Read operations during the Chip Erase operation will output the Status Register on the Data Inputs/Outputs. See the section on the Status Register for more details. After the Chip Erase operation has completed the memory will return to the Read Mode, unless an error has occurred. When an error occurs the memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read Mode. 17/39 Command interface M29F200BT, M29F200BB The Chip Erase Command sets all of the bits in unprotected blocks of the memory to '1'. All previous data is lost. 4.0.8 Block Erase command The Block Erase command can be used to erase a list of one or more blocks. Six Bus Write operations are required to select the first block in the list. Each additional block in the list can be selected by repeating the sixth Bus Write operation using the address of the additional block. The Block Erase operation starts the Program/Erase Controller about 50s after the last Bus Write operation. Once the Program/Erase Controller starts it is not possible to select any more blocks. Each additional block must therefore be selected within 50s of the last block. The 50s timer restarts when an additional block is selected. The Status Register can be read after the sixth Bus Write operation. See the Status Register for details on how to identify if the Program/Erase Controller has started the Block Erase operation. If any selected blocks are protected then these are ignored and all the other selected blocks are erased. If all of the selected blocks are protected the Block Erase operation appears to start but will terminate within about 100s, leaving the data unchanged. No error condition is given when protected blocks are ignored. During the Block Erase operation the memory will ignore all commands except the Erase Suspend and Read/Reset commands. Typical block erase times are given in Table 6. All Bus Read operations during the Block Erase operation will output the Status Register on the Data Inputs/Outputs. See the section on the Status Register for more details. After the Block Erase operation has completed the memory will return to the Read Mode, unless an error has occurred. When an error occurs the memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode. The Block Erase Command sets all of the bits in the unprotected selected blocks to '1'. All previous data in the selected blocks is lost. 4.0.9 Erase Suspend command The Erase Suspend Command may be used to temporarily suspend a Block Erase operation and return the memory to Read mode. The command requires one Bus Write operation. The Program/Erase Controller will suspend within 15s of the Erase Suspend Command being issued. Once the Program/Erase Controller has stopped the memory will be set to Read mode and the Erase will be suspended. If the Erase Suspend command is issued during the period when the memory is waiting for an additional block (before the Program/Erase Controller starts) then the Erase is suspended immediately and will start immediately when the Erase Resume Command is issued. It will not be possible to select any further blocks for erasure after the Erase Resume. During Erase Suspend it is possible to Read and Program cells in blocks that are not being erased; both Read and Program operations behave as normal on these blocks. Reading from blocks that are being erased will output the Status Register. It is also possible to enter the Auto Select mode: the memory will behave as in the Auto Select mode on all blocks until a Read/Reset command returns the memory to Erase Suspend mode. 18/39 M29F200BT, M29F200BB 4.0.10 Command interface Erase Resume command The Erase Resume command must be used to restart the Program/Erase Controller from Erase Suspend. An erase can be suspended and resumed more than once. Table 4. Commands, 16-bit mode, BYTE = VIH Command Length Bus Write operations 1st 2nd 3rd 4th 5th 6th Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data 1 X F0 3 555 AA 2AA 55 X F0 Auto Select 3 555 AA 2AA 55 555 90 Program 4 555 AA 2AA 55 555 A0 Unlock Bypass 3 555 AA 2AA 55 555 20 Unlock Bypass Program 2 X A0 PA PD Unlock Bypass Reset 2 X 90 X 00 Chip Erase 6 555 AA 2AA 55 555 Block Erase 6+ 555 AA 2AA 55 555 Erase Suspend 1 X B0 Erase Resume 1 X 30 Read/Reset PA PD 80 555 AA 2AA 55 555 10 80 555 AA 2AA 55 BA 30 19/39 Command interface M29F200BT, M29F200BB Commands, 8-bit mode, BYTE = VIL(1)(2)(3) Table 5. Command Length Bus Write operations 1st 2nd 3rd 4th 5th 6th Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data 1 X F0 3 AAA AA 555 55 X F0 3 AAA AA 555 55 AAA 90 4 AAA AA 555 55 AAA A0 Unlock Bypass 3 AAA AA 555 55 AAA 20 Unlock Bypass Program(6) 2 X A0 PA PD Unlock Bypass Reset(8) 2 X 90 X 00 (6) 6 AAA AA 555 55 AAA 555 55 AAA Read/Reset(4) (5) Auto Select Program(6) (7) Chip Erase (6) 6+ AAA AA (9) Erase Suspend 1 X B0 Erase Resume(10) 1 X 30 Block Erase PA PD 80 AAA AA 555 55 AAA 10 80 AAA AA 555 55 BA 30 1. X Don't Care, PA Program Address, PD Program Data, BA Any address in the Block. 2. All values in the table are in hexadecimal. 3. The Command Interface only uses A-1, A0-A10 and DQ0-DQ7 to verify the commands; A11-A16, DQ8-DQ14 and DQ15 are Don't Care. DQ15A-1 is A-1 when BYTE is VIL or DQ15 when BYTE is VIH. 4. After a Read/Reset command, read the memory as normal until another command is issued. 5. After an Auto Select command, read Manufacturer ID, Device ID or Block Protection Status. 6. After a Program, Unlock Bypass Program, Chip Erase, or Block Erase command, read the Status Register until the Program/Erase Controller completes and the memory returns to Read Mode. Add additional Blocks during Block Erase Command with additional Bus Write Operations until the Timeout Bit is set. 7. After the Unlock Bypass command, issue Unlock Bypass Program or Unlock Bypass Reset commands. 8. After the Unlock Bypass Reset command read the memory as normal until another command is issued. 9. After the Erase Suspend command, read non-erasing memory blocks as normal, issue Auto Select and Program commands on non-erasing blocks as normal. 10. After the Erase Resume command the suspended Erase operation resumes, read the Status Register until the Program/Erase Controller completes and the memory returns to Read Mode. 20/39 M29F200BT, M29F200BB Table 6. Command interface Program, Erase times and Program, Erase endurance cycles (TA = 0 to 70C, -40 to 85C or -40 to 125C) Typ(1) Typical after 100k W/E Cycles(1) Chip Erase (All bits in the memory set to `0') 0.8 0.8 Chip Erase 2.5 2.5 10 s Block Erase (64 Kbytes) 0.6 0.6 4 s Program (Byte or Word) 8 8 150 s Chip Program (Byte by Byte) 2.3 2.3 9 s Chip Program (Word by Word) 1.2 1.2 4.5 s Parameter Program/Erase Cycles (per Block) Min 100,000 Max Unit s cycles 1. TA = 25C, VCC = 5V. 21/39 Status register 5 M29F200BT, M29F200BB Status register Bus Read operations from any address always read the Status Register during Program and Erase operations. It is also read during Erase Suspend when an address within a block being erased is accessed. The bits in the Status Register are summarized in Table 7: Status Register Bits. 5.1 Data Polling Bit (DQ7) The Data Polling Bit can be used to identify whether the Program/Erase Controller has successfully completed its operation or if it has responded to an Erase Suspend. The Data Polling Bit is output on DQ7 when the Status Register is read. During Program operations the Data Polling Bit outputs the complement of the bit being programmed to DQ7. After successful completion of the Program operation the memory returns to Read mode and Bus Read operations from the address just programmed output DQ7, not its complement. During Erase operations the Data Polling Bit outputs '0', the complement of the erased state of DQ7. After successful completion of the Erase operation the memory returns to Read Mode. In Erase Suspend mode the Data Polling Bit will output a '1' during a Bus Read operation within a block being erased. The Data Polling Bit will change from a '0' to a '1' when the Program/Erase Controller has suspended the Erase operation. Figure 4: Data polling flowchart, gives an example of how to use the Data Polling Bit. A Valid Address is the address being programmed or an address within the block being erased. 5.2 Toggle Bit (DQ6) The Toggle Bit can be used to identify whether the Program/Erase Controller has successfully completed its operation or if it has responded to an Erase Suspend. The Toggle Bit is output on DQ6 when the Status Register is read. During Program and Erase operations the Toggle Bit changes from '0' to '1' to '0', etc., with successive Bus Read operations at any address. After successful completion of the operation the memory returns to Read mode. During Erase Suspend mode the Toggle Bit will output when addressing a cell within a block being erased. The Toggle Bit will stop toggling when the Program/Erase Controller has suspended the Erase operation. Figure 5: Data toggle flowchart, gives an example of how to use the Data Toggle Bit. 5.3 Error Bit (DQ5) The Error Bit can be used to identify errors detected by the Program/Erase Controller. The Error Bit is set to '1' when a Program, Block Erase or Chip Erase operation fails to write the correct data to the memory. If the Error Bit is set a Read/Reset command must be issued 22/39 M29F200BT, M29F200BB Status register before other commands are issued. The Error bit is output on DQ5 when the Status Register is read. Note that the Program command cannot change a bit set at '0' back to '1' and attempting to do so may or may not set DQ5 at `1'. In both cases, a successive Bus Read operation will show the bit is still '0'. One of the Erase commands must be used to set all the bits in a block or in the whole memory from '0' to '1'. 5.4 Erase Timer Bit (DQ3) The Erase Timer Bit can be used to identify the start of Program/Erase Controller operation during a Block Erase command. Once the Program/Erase Controller starts erasing the Erase Timer Bit is set to '1'. Before the Program/Erase Controller starts the Erase Timer Bit is set to '0' and additional blocks to be erased may be written to the Command Interface. The Erase Timer Bit is output on DQ3 when the Status Register is read. 5.5 Alternative Toggle Bit (DQ2) The Alternative Toggle Bit can be used to monitor the Program/Erase controller during Erase operations. The Alternative Toggle Bit is output on DQ2 when the Status Register is read. During Chip Erase and Block Erase operations the Toggle Bit changes from '0' to '1' to '0', etc., with successive Bus Read operations from addresses within the blocks being erased. Once the operation completes the memory returns to Read mode. During Erase Suspend the Alternative Toggle Bit changes from '0' to '1' to '0', etc. with successive Bus Read operations from addresses within the blocks being erased. Bus Read operations to addresses within blocks not being erased will output the memory cell data as if in Read mode. After an Erase operation that causes the Error Bit to be set the Alternative Toggle Bit can be used to identify which block or blocks have caused the error. The Alternative Toggle Bit changes from '0' to '1' to '0', etc. with successive Bus Read Operations from addresses within blocks that have not erased correctly. The Alternative Toggle Bit does not change if the addressed block has erased correctly. 23/39 Status register M29F200BT, M29F200BB Table 7. Status Register Bits(1) Operation Address DQ7 DQ6 DQ5 DQ3 DQ2 RB Program Any Address DQ7 Toggle 0 - - 0 Program during Erase Suspend Any Address DQ7 Toggle 0 - - 0 Program Error Any Address DQ7 Toggle 1 - - 0 Chip Erase Any Address 0 Toggle 0 1 Toggle 0 Erasing Block 0 Toggle 0 0 Toggle 0 Non-Erasing Block 0 Toggle 0 0 No Toggle 0 Erasing Block 0 Toggle 0 1 Toggle 0 Non-Erasing Block 0 Toggle 0 1 No Toggle 0 Erasing Block 1 No Toggle 0 - Toggle 1 Block Erase before timeout Block Erase Erase Suspend Non-Erasing Block Data read as normal 1 Good Block Address 0 Toggle 1 1 No Toggle 0 Faulty Block Address 0 Toggle 1 1 Toggle 0 Erase Error 1. Unspecified data bits should be ignored. 24/39 M29F200BT, M29F200BB Figure 4. Status register Data polling flowchart START READ DQ5 & DQ7 at VALID ADDRESS DQ7 = DATA YES NO NO DQ5 =1 YES READ DQ7 at VALID ADDRESS DQ7 = DATA YES NO FAIL PASS AI03598 25/39 Status register Figure 5. M29F200BT, M29F200BB Data toggle flowchart START READ DQ5 & DQ6 READ DQ6 DQ6 = TOGGLE NO YES NO DQ5 =1 YES READ DQ6 TWICE DQ6 = TOGGLE NO YES FAIL PASS AI01370B 26/39 M29F200BT, M29F200BB 6 Maximum rating Maximum rating Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. Table 8. Absolute maximum ratings(1) Symbol Value Unit Ambient operating temperature (temperature range option 1) 0 to 70 C Ambient operating temperature (temperature range option 6) -40 to 85 C Ambient Operating Temperature (Temperature Range Option 3) -40 to 125 C TBIAS Temperature under bias -50 to 125 C TSTG Storage temperature -65 to 150 C VIO(2) Input or output voltage -0.6 to 6 V VCC Supply Voltage -0.6 to 6 V VID Identification voltage -0.6 to 13.5 V TA Parameter 1. Except for the Operating Temperature Range, stresses above those listed in the Table 8: Absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. 2. Minimum Voltage may undershoot to -2V during transition and for less than 20ns during transitions. 27/39 DC and ac parameters 7 M29F200BT, M29F200BB DC and ac parameters This section summarizes the operating measurement conditions, and the dc and ac characteristics of the device. The parameters in the dc and ac characteristics Tables that follow, are derived from tests performed under the Measurement Conditions summarized in Table 9: Operating and ac measurement conditions. Designers should check that the operating conditions in their circuit match the operating conditions when relying on the quoted parameters. Table 9. Operating and ac measurement conditions M29F200B Parameter 45 / 50 70 / 90 High Speed Standard 30pF 100pF Input Rise and Fall Times 10ns 10ns Input Pulse Voltages 0 to 3V 0.45 to 2.4V 1.5V 0.8V and 2.0V AC Test Conditions Load Capacitance (CL) Input and Output Timing Ref. Voltages Table 10. Symbol CIN COUT Capacitance (TA = 25 C, f = 1 MHz)(1) Parameter Input Capacitance Output Capacitance Test condition Min Max Unit VIN = 0V 6 pF VOUT = 0V 12 pF 1. Sampled only, not 100% tested. Figure 6. AC testing input output waveform High Speed 3V 1.5V 0V Standard 2.4V 0.45V 2.0V 0.8V AI01275B 28/39 M29F200BT, M29F200BB Figure 7. DC and ac parameters AC testing load circuit 1.3V 1N914 3.3k DEVICE UNDER TEST OUT CL = 30pF or 100pF CL includes JIG capacitance Table 11. Symbol AI03027 DC characteristics (TA = 0 to 70C, -40 to 85C or -40 to 125C) Parameter Test Condition Min Typ(1) Max Unit 0V VIN VCC 1 A 1 A 20 mA 1 mA 100 A 20 mA ILI Input Leakage Current ILO Output Leakage Current 0V VOUT VCC ICC1 Supply Current (Read) E = VIL, G = VIH, f = 6MHz ICC2 Supply Current (Standby) TTL ICC3 Supply Current (Standby) CMOS E = VCC 0.2V, RP = VCC 0.2V ICC4(2) Supply Current (Program/Erase) Program/Erase Controller active VIL Input Low Voltage -0.5 0.8 V VIH Input High Voltage 2 VCC +0.5 V VOL Output Low Voltage 0.45 V VOH E = VIH 30 IOL = 5.8mA Output High Voltage TTL IOH = -2.5mA 2.4 V Output High Voltage CMOS IOH = -100A VCC -0.4 V VID Identification Voltage IID Identification Current VLKO(2) 6 Program/Erase Lockout Supply Voltage 11.5 A9 = VID 3.2 12.5 V 100 A 4.2 V 1. TA = 25C, VCC = 5V. 2. Sampled only, not 100% tested. 29/39 DC and ac parameters Table 12. M29F200BT, M29F200BB Read ac characteristics (TA = 0 to 70C, -40 to 85C or -40 to 125C) M29F200B Symbol Alt Parameter Test Condition Unit 45 50 70 / 90 tAVAV tRC Address Valid to Next Address Valid E = VIL, G = VIL Min 45 50 70 ns tAVQV tACC Address Valid to Output Valid E = VIL, G = VIL Max 45 50 70 ns tELQX(1) tLZ Chip Enable Low to Output Transition G = VIL Min 0 0 0 ns tELQV tCE Chip Enable Low to Output Valid G = VIL Max 45 50 70 ns tGLQX(1) tOLZ Output Enable Low to Output Transition E = VIL Min 0 0 0 ns tGLQV tOE Output Enable Low to Output Valid E = VIL Max 25 30 30 ns tEHQZ(1) tHZ Chip Enable High to Output Hi-Z G = VIL Max 15 18 20 ns tGHQZ(1) tDF Output Enable High to Output Hi-Z E = VIL Max 15 18 20 ns tEHQX tGHQX tAXQX tOH Chip Enable, Output Enable or Address Transition to Output Transition Min 0 0 0 ns tELBL tELBH tELFL tELFH Chip Enable to BYTE Low or High Max 5 5 5 ns tBLQZ tFLQZ BYTE Low to Output Hi-Z Max 15 15 20 ns tBHQV tFHQV BYTE High to Output Valid Max 30 30 30 ns 1. Sampled only, not 100% tested. Figure 8. Read Mode ac waveforms tAVAV A0-A16/ A-1 VALID tAVQV tAXQX E tELQV tEHQX tELQX tEHQZ G tGLQX tGHQX tGLQV tGHQZ DQ0-DQ7/ DQ8-DQ15 VALID tBHQV BYTE tELBL/tELBH 30/39 tBLQZ AI02915 M29F200BT, M29F200BB Table 13. DC and ac parameters Write ac characteristics, Write Enable controlled (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) M29F200B Symbol Alt Parameter Unit 45 50 70 / 90 tAVAV tWC Address Valid to Next Address Valid Min 45 50 70 ns tELWL tCS Chip Enable Low to Write Enable Low Min 0 0 0 ns tWLWH tWP Write Enable Low to Write Enable High Min 40 40 45 ns tDVWH tDS Input Valid to Write Enable High Min 25 25 30 ns tWHDX tDH Write Enable High to Input Transition Min 0 0 0 ns tWHEH tCH Write Enable High to Chip Enable High Min 0 0 0 ns tWHWL tWPH Write Enable High to Write Enable Low Min 20 20 20 ns tAVWL tAS Address Valid to Write Enable Low Min 0 0 0 ns tWLAX tAH Write Enable Low to Address Transition Min 40 40 45 ns Output Enable High to Write Enable Low Min 0 0 0 ns tOEH Write Enable High to Output Enable Low Min 0 0 0 ns tBUSY Program/Erase Valid to RB Low Max 30 30 30 ns tVCS VCC High to Chip Enable Low Min 50 50 50 s tGHWL tWHGL tWHRL (1) tVCHEL 1. Sampled only, not 100% tested. Figure 9. Write ac waveforms, Write Enable controlled tAVAV A0-A16/ A-1 VALID tWLAX tAVWL tWHEH E tELWL tWHGL G tGHWL tWLWH W tWHWL tDVWH DQ0-DQ7/ DQ8-DQ15 tWHDX VALID VCC tVCHEL RB tWHRL AI01991 31/39 DC and ac parameters Table 14. M29F200BT, M29F200BB Write AC Characteristics, Chip Enable Controlled (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) M29F200B Symbol Alt Parameter Unit 45 50 70 / 90 tAVAV tWC Address Valid to Next Address Valid Min 45 50 70 ns tWLEL tWS Write Enable Low to Chip Enable Low Min 0 0 0 ns tELEH tCP Chip Enable Low to Chip Enable High Min 40 40 45 ns tDVEH tDS Input Valid to Chip Enable High Min 25 25 30 ns tEHDX tDH Chip Enable High to Input Transition Min 0 0 0 ns tEHWH tWH Chip Enable High to Write Enable High Min 0 0 0 ns tEHEL tCPH Chip Enable High to Chip Enable Low Min 20 20 20 ns tAVEL tAS Address Valid to Chip Enable Low Min 0 0 0 ns tELAX tAH Chip Enable Low to Address Transition Min 40 40 45 ns Output Enable High Chip Enable Low Min 0 0 0 ns tGHEL tEHGL tOEH Chip Enable High to Output Enable Low Min 0 0 0 ns tEHRL(1) tBUSY Program/Erase Valid to RB Low Max 30 30 30 ns tVCHWL tVCS VCC High to Write Enable Low Min 50 50 50 s 1. Sampled only, not 100% tested. Figure 10. Write ac waveforms, Chip Enable controlled tAVAV A0-A16/ A-1 VALID tELAX tAVEL tEHWH W tWLEL tEHGL G tGHEL tELEH E tEHEL tDVEH DQ0-DQ7/ DQ8-DQ15 tEHDX VALID VCC tVCHWL RB tEHRL 32/39 AI01992 M29F200BT, M29F200BB Table 15. DC and ac parameters Reset/Block Temporary Unprotect AC Characteristics (TA = 0 to 70 C, -40 to 85 C or -40 to 125 C) M29F200B Symbol Alt Parameter Unit 45 50 70 / 90 tPHWL(1) tPHEL tPHGL(1) tRH RP High to Write Enable Low, Chip Enable Low, Output Enable Low Min 50 50 50 ns tRHWL(1) tRHEL(1) tRHGL(1) tRB RB High to Write Enable Low, Chip Enable Low, Output Enable Low Min 0 0 0 ns tPLPX tRP RP Pulse Width Min 500 500 500 ns RP Low to Read Mode Max 10 10 10 s RP Rise Time to VID Min 500 500 500 ns tPLYH (1) tPHPHH(1) tREADY tVIDR 1. Sampled only, not 100% tested. Figure 11. Reset/Block Temporary Unprotect ac waveforms W, E, G tPHWL, tPHEL, tPHGL RB tRHWL, tRHEL, tRHGL RP tPLPX tPHPHH tPLYH AI02931 33/39 Package Mechanical 8 M29F200BT, M29F200BB Package Mechanical Figure 12. TSOP48 - 48 lead Plastic Thin Small Outline, 12 x 20mm, package outline 1 48 e D1 B 24 L1 25 A2 E1 E A A1 DIE L C CP TSOP-G 1. Drawing is not to scale. Table 16. TSOP48 - 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Mechanical Data millimeters inches Symbol Typ Min A Typ Min 1.200 Max 0.0472 A1 0.100 0.050 0.150 0.0039 0.0020 0.0059 A2 1.000 0.950 1.050 0.0394 0.0374 0.0413 B 0.220 0.170 0.270 0.0087 0.0067 0.0106 0.100 0.210 0.0039 0.0083 C CP 34/39 Max 0.100 0.0039 D1 12.000 11.900 12.100 0.4724 0.4685 0.4764 E 20.000 19.800 20.200 0.7874 0.7795 0.7953 E1 18.400 18.300 18.500 0.7244 0.7205 0.7283 e 0.500 - - 0.0197 - - L 0.600 0.500 0.700 0.0236 0.0197 0.0276 L1 0.800 3 0 5 0.0315 0 5 3 M29F200BT, M29F200BB Package Mechanical Figure 13. SO44 - 44 lead Plastic Small Outline, 500 mils body width, package outline D 44 23 c E1 E 1 22 A1 A2 b A L L1 ddd e SO-F 1. Drawing is not to scale. Table 17. SO44 - 44 lead Plastic Small Outline, 500 mils body width, package mechanical data millimeters inches Symbol Typ Min A Max Min 3.00 A1 0.10 A2 2.69 2.79 b 0.35 c 28.50 Max 0.118 0.004 2.56 D Typ 0.101 0.110 0.50 0.014 0.020 0.18 0.28 0.007 0.011 28.37 28.63 1.117 1.127 ddd 0.106 1.122 0.10 0.004 E 16.03 15.77 16.28 0.631 0.621 0.641 E1 12.60 12.47 12.73 0.496 0.491 0.501 e 1.27 - - 0.050 - - L 0.79 0.031 L1 1.73 0.068 N 8 44 8 44 35/39 Part numbering 9 M29F200BT, M29F200BB Part numbering Table 18. Ordering information scheme Example: M29F200BB 50 N 1 T Device Type M29 Operating Voltage F = VCC = 5V 10% Device Function 200B = 2 Mbit (256Kb x8 or 128Kb x16), Boot Block Array Matrix T = Top Boot B = Bottom Boot Speed 45 = 45 ns 50 = 50 ns(1) 70 = 70 ns 90 = 90 ns Package N = TSOP48: 12 x 20 mm M = SO44 500mm width Temperature Range 1 = 0 to 70 C 3 = -40 to 125 C 6 = -40 to 85 C Option Blank = Standard Packing T = Tape & Reel Packing E = ECOPACK Package, Standard Packing F = ECOPACK Package, Tape & Reel Packing 1. 50ns speed devices are only available in M29F200BB in Temperature Range option 3. The last two characters of the ordering code may be replaced by a letter code for preprogrammed parts, otherwise devices are shipped from the factory with the memory content bits erased to '1'. For a list of available options (Speed, Package, etc...) or for further information on any aspect of this device, please contact the ST Sales Office nearest to you. 36/39 M29F200BT, M29F200BB Appendix A Table 19. Block addresses Block addresses Top Boot block addresses, M29F200BT # Size (Kbytes) Address Range (x8) Address Range (x16) 6 16 3C000h-3FFFFh 1E000h-1FFFFh 5 8 3A000h-3BFFFh 1D000h-1DFFFh 4 8 38000h-39FFFh 1C000h-1CFFFh 3 32 30000h-37FFFh 18000h-1BFFFh 2 64 20000h-2FFFFh 10000h-17FFFh 1 64 10000h-1FFFFh 08000h-0FFFFh 0 64 00000h-0FFFFh 00000h-07FFFh Table 20. Bottom Boot Block Addresses, M29F200BB # Size (Kbytes) Address Range (x8) Address Range (x16) 6 64 30000h-3FFFFh 18000h-1FFFFh 5 64 20000h-2FFFFh 10000h-17FFFh 4 64 10000h-1FFFFh 08000h-0FFFFh 3 32 08000h-0FFFFh 04000h-07FFFh 2 8 06000h-07FFFh 03000h-03FFFh 1 8 04000h-05FFFh 02000h-02FFFh 0 16 00000h-03FFFh 00000h-01FFFh 37/39 Revision history 10 M29F200BT, M29F200BB Revision history Table 21. Document revision history Date Revision July 1999 1.0 First Issue 2.0 Chip Erase Max. specification added (Table 6) Block Erase Max. specification added (Table 6) Program Max. specification added (Table 6) Chip Program Max. specification added (Table 6) ICC1 and ICC3 Typ. specification added (Table 11) ICC3 Test Condition changed (Table 11) 3.0 New document template Document type: from Preliminary Data to Data Sheet Status Register bit DQ5 clarification Data Polling Flowchart diagram change (Figure 4) Data Toggle Flowchart diagram change (Figure 5) 19-Sep-2005 4.0 Document restructured. Table 18: Ordering information scheme: standard package added and ECOPACK version added for both standard package and Tape & Reel packing. Note 1 modified. 55ns speed class replaced by 50ns. TSOP48 mechanical data updated, and SO44 525mm body width changed to SO44 500mm body width. 22-Mar-2007 5 10/08/99 07/28/00 38/39 Changes Document restructured. SO44 package code changed to `M' inSection : Features and in Table 18: Ordering information scheme. M29F200BT, M29F200BB Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries ("ST") reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST's terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST'S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED ST REPRESENTATIVE, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER'S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. (c) 2007 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com 39/39