NEW Series X Output to 16A 280 Vac DC Control Part Number Description X24D12 12A, 280 Vac X24D16 16A, 280 Vac Part Number Explanation X 24 D 12 FEATURES/BENEFITS * Compact size * Spring terminals * Tight zero-cross window for low EMI * Touch-proof terminals * Designed for medium-power applications NOTES 1) Line Voltage (nominal): 24 = 240 Vac 2) Switch Type: D = Zero-cross turn-on .708 (18) 1.3 (33) MECHANICAL SPECIFICATION 3.15 (80) .882 (2.4) .177 (4.5) - + WEIGHT: 3.175 oz. (90g) 2.756 to 2.953 (70 to 75) Figure 1 -- X relays; dimensions in inches (mm) Wires L APPLICATIONS * Heating control * Motor control * Uninterruptible power supplies * Light dimmers * Industrial and process control * On/Off controls of medium-power AC equipment APPROVALS Series X relays are UL pending. CONNECTIONS L DESCRIPTION The Series X relays are designed in a thin compact plastic package. The X relays offer touch-proof spring terminals for ease of use and user safety. With its medium-power handling capabilities and compact size, the Series X is an excellent choice for mediumpower AC loads. Tool TYPICAL APPLICATION 1 x(0.14-->2.5mm2) 1 x(22-->12AWG) L = 0.2362 (6mm) Screwdriver or fingers 12-280 Vac LOAD Line protection 1 2 L1 T1 A2 A1 - + Control Figure 2 -- X relays (c) 2003 TELEDYNE RELAYS Figure 3 -- X relays (800) 284-7007 * www.teledynerelays.com X1 X\032003\Q1 Series X INPUT (CONTROL) SPECIFICATION CONTROL CHARACTERISTIC Max Control Range 7 30 Vdc Input Current Range 5 30 mAdc Must Turn-Off Voltage Input Resistance (Typical) Reverse Voltage Protection Units 1 Vdc 1000 Ohms 30 V OUTPUT (LOAD) SPECIFICATION Operating Range Min Max 12 280 Vrms 600 Vpeak Peak Voltage Input Current (mA) Min Units 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Control Voltage (V) Load Current Range (Resistive) Figure 4 -- X relays X24D12 .005 12 Arms X24D16 .005 25* Arms SURGE CURRENT *Terminals limited at 16A Maximum Surge Current Rating (Non-Repetitive) X24D12 120 A X24D16 250 A Apeak 150 100 Non-Repetitive 50 0 Repetitive with initial Tj = 70C 0.01 On-State Voltage Drop 1.3 V Zero-Cross Window (Typical) 12 Vac 1 mA 250 8.3 ms 200 Turn-Off Time (60 Hz) 8.3 ms 500 V/s Maximum di/dt (Non-Repetitive) 50 A2 s Operating Frequency Range 0.1 440 Hz 10 Figure 5a -- X24D12 relay Turn-On Time (60 Hz) Off-State dv/dt 1 t(s) Apeak Off-State Leakage Current (60Hz) 0.1 150 Non-Repetitive 100 50 Repetitive with initial Tj = 70C 0 0.01 0.1 1 10 t(s) Figure 5b -- X24D16 relay I2t for Match Fusing (<8.3ms) X24D12 .005 72 A2S X24D16 .005 310 A2S ENVIRONMENTAL SPECIFICATION Min Max Units -40 100 C Storage Temperature -40 100 Input-Output Isolation 4000 Vrms Output-Case Isolation 2500 Vrms Operating Temperature X2 C SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2003 TELEDYNE RELAYS X\032003\Q1 Series X THERMAL CHARACTERISTICS 1.6C/W 75 1.1C/W 2.2C/W 80 18 Power Dissipation (W) 16 85 4C/W Full on state 90 14 95 6C/W 12 100 10 8 50% on state 6 4 Max Case Temperature (C) 20 2 0 0 1 2 3 4 5 6 7 8 9 10 11 12 0 10 20 30 Load Current (Arms) 40 50 60 70 80 90 100 110 120 Ambient Temperature (C) Figure 6a -- X24D12 relay 0.95C/W 40 70 0.75C/W 1.1C/W 35 Power Dissipation (W) 2.2C/W 90 25 20 100 50% on state 6C/W 15 10 Max Case Temperature (C) 80 1.6C/W Full on state 30 5 0 0 2 4 6 8 10 12 14 16 18 20 22 24 Load Current (Arms) 26 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient Temperature (C) Figure 6b -- X24D16 relay NOTES: 1. External snubber is recommended when switching inductive loads. 2. Electrical specifications at 25C unless otherwise specified. 3. For 800Hz applications, contact factory. 4. For additional/custom options, contact factory. (c) 2003 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com X3 X\032003\Q1