X 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
X\032003\Q1
SURGE CURRENT
Figure 5a — X24D12 relay
Figure 5b — X24D16 relay
INPUT (CONTROL) SPECIFICATION
Min Max Units
Control Range 7 30 Vdc
Input Current Range 5 30 mAdc
Must T urn-Of f Voltage 1 Vdc
Input Resistance (Typical) 1000 Ohms
Reverse Voltage Protection 30 V
OUTPUT (LOAD) SPECIFICATION
Min Max Units
Operating Range 12 280 Vrms
Peak Voltage 600 Vpeak
Load Current Range (Resistive)
X24D12 .005 12 Arms
X24D16 .005 25* Arms
*Terminals limited at 16A
Maximum Surge Current Rating (Non-Repetitive)
X24D12 120 A
X24D16 250 A
On-State Voltage Drop 1.3 V
Zero-Cross Window (Typical) ±12 Vac
Off-State Leakage Current (60Hz) 1 mA
Turn-On Time (60 Hz) 8.3 ms
Turn-Off Time (60 Hz) 8.3 ms
Off-State dv/dt 500 V/µs
Maximum di/dt (Non-Repetitive) 50 A2s
Operating Frequency Range 0.1 440 Hz
I2t for Match Fusing (<8.3ms)
X24D12 .005 72 A2S
X24D16 .005 310 A2S
ENVIRONMENTAL SPECIFICATION
Min Max Units
Operating Temperature –40 100 °C
Storage Temperature –40 100 °C
Input-Output Isolation 4000 Vrms
Output-Case Isolation 2500 Vrms
Series X
CONTROL CHARACTERISTIC
Figure 4 — X relays
0246810121416 1820222426 28 30
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
Control Voltage (V)
Input Current (mA)
1100.1
Non-Repetitive
0.01
0
50
100
150
t(s)
Apeak
Repetitive with initial Tj = 70°C
1100.1
Non-Repetitive
0.01
0
50
100
150
200
250
t(s)
Apeak
Repetitive with initial Tj = 70°C