Document Number: 94353 For technical questions, contact: indmodules@vishay.com www.vishay.com
Revision: 13-Aug-08 1
Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Vishay High Power Products
FEATURES
Package fully compatible with the industry
standard INT-A-PAK power modules series
High thermal conductivity package, electrically
insulated case
Excellent power volume ratio
4000 VRMS isolating voltage
UL E78996 approved
Compliant to RoHS directive 2002/95/EC
Designed and qualified for industrial level
DESCRIPTION
A range of extremely compact, encapsulated three phase
controlled bridge rectifiers offering efficient and reliable
operation. They are intended for use in general purpose and
heavy duty applications.
PRODUCT SUMMARY
IO 55 A to 110 A
MTK
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL CHARACTERISTICS 5.MT...K 9.MT...K 11.MT...K UNITS
IO
55 90 110 A
TC85 85 85 °C
IFSM
50 Hz 390 950 1130
A
60 Hz 410 1000 1180
I2t
50 Hz 770 4525 6380
A2s
60 Hz 700 4130 5830
I2t 7700 45 250 63 800 A2s
VRRM Range 800 to 1600 V
TStg, TJRange - 40 to 125 °C
www.vishay.com For technical questions, contact: indmodules@vishay.com Document Number: 94353
2Revision: 13-Aug-08
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Vishay High Power Products Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
TYPE NUMBER VOLTAGE
CODE
VRRM, MAXIMUM
REPETITIVE PEAK
REVERSE VOLTAGE
V
VRSM, MAXIMUM
NON-REPETITIVE PEAK
REVERSE VOLTAGE
V
VDRM, MAXIMUM REPETITIVE
PEAK OFF-STATE VOLTAGE,
GATE OPEN CIRCUIT
V
IRRM/IDRM,
MAXIMUM
AT TJ = 125 °C
mA
5.MT...K
80 800 900 800
10
100 1000 1100 1000
120 1200 1300 1200
140 1400 1500 1400
160 1600 1700 1600
9.MT...K
11.MT...K
80 800 900 800
20
100 1000 1100 1000
120 1200 1300 1200
140 1400 1500 1400
160 1600 1700 1600
FORWARD CONDUCTION
PARAMETER SYMBOL TEST CONDITIONS 5.MT...K 9.MT...K 11.MT...K UNITS
Maximum DC output
current at case temperature IO120° rect. conduction angle 55 90 110 A
85 85 85 °C
Maximum peak, one-cycle
forward, non-repetitive
on state surge current
ITSM
t = 10 ms No voltage
reapplied
Initial TJ = TJ maximum
390 950 1130
A
t = 8.3 ms 410 1000 1180
t = 10 ms 100 % VRRM
reapplied
330 800 950
t = 8.3 ms 345 840 1000
Maximum I2t for fusing I2t
t = 10 ms No voltage
reapplied
770 4525 6380
A2s
t = 8.3 ms 700 4130 5830
t = 10 ms 100 % VRRM
reapplied
540 3200 4510
t = 8.3 ms 500 2920 4120
Maximum I2t for fusing I2t t = 0.1 ms to 10 ms, no voltage reapplied 7700 45 250 63 800 A2s
Low level value of
threshold voltage VT(TO)1 (16.7 % x π x IT(AV) < I < π x IT(AV)), TJ maximum 1.17 1.09 1.04
V
High level value of
threshold voltage VT(TO)2 (I > π x IT(AV)), TJ maximum 1.45 1.27 1.27
Low level value on-state
slope resistance rt1 (16.7 % x π x IT(AV) < I < π x IT(AV)), TJ maximum 12.40 4.10 3.93
mΩ
High level value on-state
slope resistance rt2 (I > π x IT(AV)), TJ maximum 11.04 3.59 3.37
Maximum on-state
voltage drop VTM Ipk = 150 A, TJ = 25 °C, tp = 400 μs single junction 2.68 1.65 1.57 V
Maximum non-repetitve
rate of rise of turned on
current
dI/dt TJ = 25 °C, from 0.67 VDRM, ITM = π x IT(AV),
Ig = 500 mA, tr < 0.5 μs, tp > 6 μs 150 A/μs
Maximum holding current IH
TJ = 25 °C, anode supply = 6 V,
resistive load, gate open circuit 200 mA
Maximum latching current ILTJ = 25 °C, anode supply = 6 V, resistive load 400
Document Number: 94353 For technical questions, contact: indmodules@vishay.com www.vishay.com
Revision: 13-Aug-08 3
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A Vishay High Power Products
Note
(1) Available with dV/dt = 1000 V/μs, to complete code add S90 i. e. 113MT160KBS90
BLOCKING
PARAMETER SYMBOL TEST CONDITIONS 5.MT...K 9.MT...K 11.MT...K UNITS
RMS isolation voltage VISOL TJ = 25 °C all terminal shorted, f = 50 Hz, t = 1 s 4000 V
Maximum critical rate of rise of
off-state voltage dV/dt (1) TJ = TJ maximum, linear to 0.67 VDRM,
gate open circuit 500 V/μs
TRIGGERING
PARAMETER SYMBOL TEST CONDITIONS 5.MT...K 9.MT...K 11.MT...K UNITS
Maximum peak gate power PGM
TJ = TJ maximum
10 W
Maximum average gate power PG(AV) 2.5
Maximum peak gate current IGM 2.5 A
Maximum peak negative
gate voltage - VGT 10
V
Maximum required DC gate
voltage to trigger VGT
TJ = - 40 °C
Anode supply = 6 V,
resistive load
4.0
TJ = 25 °C 2.5
TJ = 125 °C 1.7
Maximum required DC gate
current to trigger IGT
TJ = - 40 °C 270
mATJ = 25 °C 150
TJ = 125 °C 80
Maximum gate voltage
that will not trigger VGD
TJ = TJ maximum, rated VDRM applied
0.25 V
Maximum gate current
that will not trigger IGD 6mA
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS 5.MT...K 9.MT...K 11.MT...K UNITS
Maximum junction operating
and storage temperature range TJ, TStg - 40 to 125 °C
Maximum thermal resistance,
junction to case RthJC
DC operation per module 0.18 0.14 0.12
K/W
DC operation per junction 1.07 0.86 0.70
120 °C rect. conduction angle per module 0.19 0.15 0.12
120 °C rect. conduction angle per junction 1.17 0.91 0.74
Maximum thermal resistance,
case to heatsink per module RthCS Mounting surface smooth, flat and grased 0.03
Mounting
torque ± 10 %
to heatsink A mounting compound is recommended and
the torque should be rechecked after a period of
3 hours to allow for the spread of the
compound. Lubricated threads.
4 to 6 Nm
to terminal 3 to 4
Approximate weight 225 g
www.vishay.com For technical questions, contact: indmodules@vishay.com Document Number: 94353
4Revision: 13-Aug-08
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Vishay High Power Products Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A
Note
Table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
Fig. 1 - Current Ratings Characteristic Fig. 2 - Forward Voltage Drop Characteristics
Fig. 3 - Total Power Loss Characteristics
ΔR CONDUCTION PER JUNCTION
DEVICES
SINUSOIDAL CONDUCTION
AT TJ MAXIMUM
RECTANGULAR CONDUCTION
AT TJ MAXIMUM UNITS
180° 120° 90° 60° 30° 180° 120° 90° 60° 30°
5.MT...K 0.072 0.085 0.108 0.152 0.233 0.055 0.091 0.117 0.157 0.236
K/W9.MT...K 0.033 0.039 0.051 0.069 0.099 0.027 0.044 0.055 0.071 0.100
11.MT...K 0.027 0.033 0.042 0.057 0.081 0.023 0.037 0.046 0.059 0.082
Maximum Allowable
Case Temperature (°C)
Total Output Current (A)
10 20 30 40 50 60
0
120°
(Rect.)
5.MT..K Series
100
120
130
80
94353_01
90
110
~
+
-
Instantaneous On-State Current (A)
Instantaneous On-State Voltage (V)
21 34567
0
94353_02
TJ = 25 °C
5.MT..K Series
Per junction
TJ = 125 °C
100
1000
1
10
Maximum Total Power Loss (W)
Total Output Current (A)
51510 25 353020 40 5045 55
0
94353_03a
80
60
180
220
0
20
140
100
120
200
40
160
120°
(Rect.)
5.MT..K Series
TJ = 125 °C
Maximum Total Power Loss (W)
Maximum Allowable Ambient
Temperature (°C)
25 50 75 100 125
0
R
thSA
= 0.05 K/W - ΔR
0.12 K/W
0.2 K/W
0.3 K/W
0.4 K/W
0.5 K/W
0.7 K/W
1.0 K/W
1.5 K/W
80
60
180
220
0
20
140
100
120
200
40
160
94353_03b
Document Number: 94353 For technical questions, contact: indmodules@vishay.com www.vishay.com
Revision: 13-Aug-08 5
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A Vishay High Power Products
Fig. 4 - Maximum Non-Repetitive Surge Current
Fig. 5 - Maximum Non-Repetitive Surge Current
Fig. 6 - Current Ratings Characteristic
Fig. 7 - Forward Voltage Drop Characteristics
Fig. 8 - Total Power Loss Characteristics
Peak Half Sine Wave
On-State Current (A)
Number of Equal Amplitude Half
Cycle Current Pulses (N)
10 100
1
94353_04
5.MT..K Series
Per junction
At any rated load condition and with
rated VRRM applied following surge.
Initial TJ = 125 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
350
150
250
200
300
Peak Half Sine Wave
On-State Current (A)
Pulse Train Duration (s)
0.1 1
0.01
Initial TJ = 125 °C
No voltage reapplied
Rated VRRM reapplied
5.MT..K Series
Per junction
400
350
150
94353_05
250
200
300
Maximum non-repetitive surge current
versus pulse train duration. Control
of conduction may not be maintained.
Maximum Allowable Case
Temperature (°C)
Total Output Current (A)
20 40 60 80 1000
120°
(Rect.)
9.MT..K Series
100
120
130
80
94353_06
90
110
~
+
-
Instantaneous On-State Current (A)
Total Output Current
1.0 2.01.50.5 2.5 3.0 3.5 4.0
TJ = 25 °C
TJ = 125 °C
94353_07
100
1000
1
10
9.MT..K Series
Per junction
Maximum Total Power Loss (W)
Total Output Current (A)
10 20 30 40 50 7060 9080
0
94353_08a
200
150
300
0
50
250
100
120°
(Rect.)
9.MT..K Series
TJ = 125 °C
Maximum Total Power Loss (W)
Maximum Allowable Ambient
Temperature (°C)
25 50 75 100 125
0
R
thSA
= 0.05 K/W - ΔR
0.12 K/W
0.2 K/W
0.3 K/W
0.4 K/W
0.5 K/W
0.7 K/W
1.0 K/W
1.5 K/W
200
150
300
0
50
250
100
94353_08b
www.vishay.com For technical questions, contact: indmodules@vishay.com Document Number: 94353
6Revision: 13-Aug-08
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Vishay High Power Products Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A
Fig. 9 - Maximum Non-Repetitive Surge Current
Fig. 10 - Maximum Non-Repetitive Surge Current
Fig. 11 - Current Ratings Characteristic
Fig. 12 - Forward Voltage Drop Characteristics
Fig. 13 - Total Power Loss Characteristics
Peak Half Sine Wave
On-State Current (A)
Number of Equal Amplitude Half
Cycle Current Pulses (N)
10 100
1
At any rated load condition and with
rated VRRM applied following surge.
Initial TJ = 125 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
94353_09
9.MT..K Series
Per junction
850
400
650
450
750
700
550
500
600
800
Peak Half Sine Wave
On-State Current (A)
Pulse Train Duration (s)
0.1 1
0.01
Maximum non-repetitive surge current
versus pulse train duration. Control
of conduction may not be maintained.
9.MT..K Series
Per junction
1000
800
300
94353_10
500
400
600
900
700
Initial TJ = 125 °C
No voltage reapplied
Rated VRRM reapplied
Maximum Allowable Case
Temperature (°C)
Total Output Current (A)
20 40 60 80 100 120
0
120°
(Rect.)
11.MT..K Series
100
120
130
80
94353_11
90
110
~
+
-
Instantaneous On-State Current (A)
Instantaneous On-State Voltage (V)
1.0 1.50.5 2.0 2.5 3.0 3.5 4.0
94353_12
100
1000
1
10
TJ = 25 °C
TJ = 125 °C
11.MT..K Series
Per junction
Maximum Total Power Loss (W)
Total Output Current
2010 4030 6050 8070 10090 110
0
94353_13a
200
150
350
0
50
250
300
100
120°
(Rect.)
11.MT..K Series
TJ = 125 °C
Maximum Allowable Ambient
Temperature (°C)
Maximum Total Power Loss (W)
25 50 75 100 125
0
R
thSA
= 0.058 K/W - ΔR
0.12 K/W
0.2 K/W
0.3 K/W
0.4 K/W
0.5 K/W
0.7 K/W
1.0 K/W
1.5 K/W
200
150
350
0
50
250
300
100
94353_13b
Document Number: 94353 For technical questions, contact: indmodules@vishay.com www.vishay.com
Revision: 13-Aug-08 7
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A Vishay High Power Products
Fig. 14 - Maximum Non-Repetitive Surge Current Fig. 15 - Maximum Non-Repetitive Surge Current
Fig. 16 - Thermal Impedance ZthJC Characteristics
Fig. 17 - Gate Characteristics
Peak Half Sine Wave
On-State Current (A)
Number of Equal Amplitude Half
Cycle Current Pulses (N)
10 1001
At any rated load condition and with
rated VRRM applied following surge.
94353_14
11.MT..K Series
Per junction
1000
400
700
500
800
600
900 Initial TJ = 125 °C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
Peak Half Sine Wave
On-State Current (A)
Pulse Train Duration (s)
0.01 0.1 1.0
Initial TJ = 125 °C
No voltage reapplied
Rated VRRM reapplied
Maximum non-repetitive surge current
versus pulse train duration. Control
of conduction may not be maintained.
11.MT..K Series
Per junction
1200
1000
400
94353_15
600
500
800
1100
700
900
0.001
0.01
0.1
1
10
0.001
94353_16
0.01 0.1 1
Square Wave Pulse Duration (s)
Z
thJC
- Transient Thermal
Impedance (K/W)
10
Per junction
5.MT..K Series
11.MT..K Series
9.MT..K Series
Steady state value
RthJC = 1.07 K/W
RthJC = 0.86 K/W
RthJC = 0.70 K/W
(DC operation)
0.01
94353_17
0.1
1
10
0.001 0.01 0.1 1
Instantaneous Gate Current (A)
Instantaneous Gate Voltage (V)
1000 100 10
(b)
(a)
(4) (3) (2) (1)
TJ = -40 °C
TJ = 25 °C
TJ = 125 °C
VGD
IGDFrequency Limited by PG(AV)
5.MT...K, 9.MT...K, 11.MT...K Series
Rectangular gate pulse
a) Recommended load line for
rated dI/dt: 20 V, 30 Ω;
t
r = 0.5 μs, tp ≥ 6 μs
b) Recommended load line for
≤ 30 % rated dI/dt: 20 V, 65 Ω
t
r = 1 μs, tp ≥ 6 μs
(1) PGM = 100 W, tp = 500 μs
(2) PGM = 50 W, tp = 1 ms
(3) PGM = 20 W, tp = 25 ms
(4) PGM = 10 W, tp = 5 ms
www.vishay.com For technical questions, contact: indmodules@vishay.com Document Number: 94353
8Revision: 13-Aug-08
5.MT...KPbF, 9.MT...KPbF, 11.MT...KPbF Series
Vishay High Power Products Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A
ORDERING INFORMATION TABLE
Note
To order the optional hardware go to www.vishay.com/doc?95172
CIRCUIT CONFIGURATION
Device code
5132 6
11 3 MT 160 K S90 PbF
4
1
3
6
- Current rating code:
5 = 55 A (average)
9 = 90 A (average)
11 = 110 A (average)
2- Circuit configuration code:
1 = Negative half-controlled bridge
2 = Positive half-controlled bridge
3 = Full-controlled bridge
- Essential part number
4- Voltage code x 10 = VRRM (see Voltage Ratings table)
- PbF = Lead (Pb)-free
5- Critical dV/dt:
None = 500 V/µs (standard value)
S90 = 1000 V/µs (special selection)
Full-controlled bridge
(5.MT...K, 9.MT...K, 11.MT..K)
A
D
1
B
EF
C
25
64 3
Positive half-controlled bridge
(5.MT...K, 9.MT...K, 11.MT..K)
AB C
DEF
125
Negative half-controlled bridge
(5.MT...K, 9.MT...K, 11.MT..K)
64 3
A
DE F
BC
LINKS TO RELATED DOCUMENTS
Dimensions www.vishay.com/doc?95004
Document Number: 95004 For technical questions, contact: indmodules@vishay.com www.vishay.com
Revision: 27-Aug-07 1
MTK (with and without optional barrier)
Outline Dimensions
Vishay Semiconductors
DIMENSIONS WITH OPTIONAL BARRIERS in millimeters (inches)
24 ± 0.5
(0.94 ± 0.02)
38 ± 0.5
(1.5 ± 0.02)
30 ± 0.5
(1.17 ± 0.02)
35 ± 0.3
(1.38 ± 0.01)
8.5 ± 0.5
(0.34 ± 0.02)
Fast-on tab 2.8 x 0.8 (type 110)
Screws M5 x 0.8 length 10
28 ± 1
(1.11 ± 0.04)
25.5 ± 0.5
(1.004 ± 0.02)
5 ± 0.3
(0.2 ± 0.01)
75 ± 0.5
(2.95 ± 0.02)
46 ± 0.3
(1.81 ± 0.01)
80 ± 0.3
(3.15 ± 0.01)
94 ± 0.3
(3.7 ± 0.01)
Ø 6.5 ± 0.2
(Ø 0.26 ± 0.01)
14 ± 0.3
(0.55 ± 0.01)
18 ± 0.3
(0.71 ± 0.01)
12
34
56
78
ABC
F
E
D
www.vishay.com For technical questions, contact: indmodules@vishay.com Document Number: 95004
2Revision: 27-Aug-07
Outline Dimensions
Vishay Semiconductors MTK (with and without optional barrier)
DIMENSIONS WITHOUT OPTIONAL BARRIERS in millimeters (inches)
24 ± 0.5
(0.94 ± 0.02)
30 ± 0.5
(1.17 ± 0.02)
35 ± 0.3
(1.38 ± 0.01)
8.5 ± 0.5
(0.34 ± 0.02)
Fast-on tab 2.8 x 0.8 (type 110)
Screws M5 x 0.8 length 10
28 ± 1
(1.11 ± 0.04)
25.5 ± 0.5
(1.004 ± 0.02)
5 ± 0.3
(0.2 ± 0.01)
75 ± 0.5
(2.95 ± 0.02)
46 ± 0.3
(1.81 ± 0.01)
80 ± 0.3
(3.15 ± 0.01)
94 ± 0.3
(3.7 ± 0.01)
Ø 6.5 ± 0.2
(Ø 0.26 ± 0.01)
14 ± 0.3
(0.55 ± 0.01)
18 ± 0.3
(0.71 ± 0.01)
12
34
56
78
ABC
F
E
D
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 02-Oct-12 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.