2
Technical Data 10339
Effective November 2017
XL60 Supercapacitors
Cylindrical cells
www.eaton.com/electronics
Ratings
Capacitance 3000 F to 3400 F
Maximum working voltage 2.70 V / 2.85 V
Surge voltage 2.85 V / 3.00 V
Capacitance tolerance 0% to +20%
Operating temperature range -40 °C to +65 °C
Extended operating temperature range -40 °C to +85 °C (with voltage derating to 2.30 V / 2.45 V @ +85 °C)
Specifications
Capacitance1 (F) Part Number
Maximum
working
voltage (V)
Maximum
initial ESR1
(mΩ)
Nominal
leakage
current2
(mA)
Stored
energy3
(Wh)
Peak
power4
(W)
Pulse
current5
(A)
Continuous
current6
(A)
Typical
thermal
resistance7
Rth (°C/W)
Short
circuit
current8
(A)
3000 XL60-2R7308W-R 2.70 0.23 5.0 3.0 7,900 2,400 143 3.2 11,700
3000 XL60-2R7308T-R 2.70 0.23 5.0 3.0 7,900 2,400 143 3.2 11,700
3400 XL60-2R9348W-R 2.85 0.23 8.0 3.8 8,800 2,700 143 3.2 12,400
3400 XL60-2R9348T-R 2.85 0.23 8.0 3.8 8,800 2,700 143 3.2 12,400
Performance
Parameter Capacitance Change
(% of initial value) ESR
(% of initial maximum value)
Lifetime — 1,500 hours at maximum rated voltage and operating temperature ≤ 20% ≤ 200%
Charge/discharge cycling9 — 1 million at +25 °C ≤ 20% ≤ 200%
Storage, uncharged, up to +35 °C — 3 years ≤ 5% ≤ 10%
1. Capacitance, Equivalent Series Resistance (ESR) and Leakage current are measured according to IEC62391-1 with current in milliamps (mA) = 8 x C x V.
2. Leakage current at +20 °C after 72 hour charge and hold.
3. Stored Energy (Wh) = 0.5 x C x V2
3600
4. Peak Power (W) = V2
4 x ESR
5. Pulse current for 1 second from full rate voltage to half voltage.(A) = 0.5 x V x C
(1 + ESR x C)
6. Continuous current with a 15 °C temperature rise. Continuous current (A) =
7. Thermal resistance (Rth) cell body temperature to ambient in open air in degrees C per Watt (°C/W).
8. Short circuit current is for safety information only. Do not use as operating current.
9. Cycling between maximum working voltage and half voltage with 3 seconds rest at +25 °C, 100 A.
Safety and Certifications
Agency information UL Recognized (3000 F), Guide BBBG2, File MH46887
Shock and vibration IEC 61373 Category 1, Class B, IEC 60068-2-6
Safety UL 810A
Environmental RoHS compliant, lead free, halogen free
Altitude, Operating 10,000 ft
Altitude, Non-operating 40,000 ft