DC/DC regulators
up to 16A / 80W
Key Features
Surface mountable
Low profi le, max 8.5mm (0.33 in)
High effi ciency
Low weight
Designed For Environment, DfE
Lead-free / Bromine-free
Robust design
Standard and full-feature versions
PMA Series
E
The PMA series of DC/DC regulators (POL) are
intended to be used as local distributed power
sources in distributed power architecture level 4. The
PMA series use a ceramic substrate with fine-pitch
components technology and a high degree of silicon
integration. Together with the electrical design using
low Rds-On MOSFET, this provides excellent thermal
management, high reliability and high efficiency. The
high efficiency makes it possible to operate over a
wide temperature range, without adding any external
heat dissipator. At forced convection cooling >1 m/s
(200 lfm), the PMA typically delivers full power up to
+80 °C ambient temperature.
The high reliability and the low profile of the
PMA series makes them particularly suited for the
communications equipment of today and tomorrow
and applications with board spacing down to 15 mm
(0.6 in). The flat case top enables pick-and-place
handling and provides a surface for attachment to
cooling surfaces in areas with limited air flow.
These products are manufactured using the most
advanced technologies and materials to comply with
environmental requirements. Designed to meet high
reliability requirements of systems manufacturers, the
PMA responds to world-class specifications.
Ericsson Power Modules is an ISO 9001/14001
certified supplier.
Ericsson Power Modules Americas
SE-141 75 Kungens Kurva, Sweden Ericsson Inc., Power Modules
Telephone: +46 8 568 69620 +1-877-374-2642
For local sales contacts, please refer to our website Asia/Pacifi c
www.ericsson.com/powermodules Ericsson Ltd.
or call: Int +46 8 568 69620, Fax: +46 8 568 69599 +852-2590-7152
New Product Overview
EN/LZT 146 011 R1D
© Ericsson Power Modules AB, August 2003
New Product Overview is intended for discussion to determine interest and requirements. Information provided is
believed to be accurate and reliable. Ericsson Power Modules makes no commitment to sample or manufacture for sale
these products and reserves the right to make changes to the product, or information contained herein, without notice.
Mechanical dataConnections
Pin Designation Function
1-2 +Out Positive output
3-4 GND Ground
5-6 +In Positive input
7 Sync In Synchronization input
8 1) Sync select Connect to ground
when used as slave
9 Sync Out Synchronization output
10 RC Remote control
11 RC sel ec t Select pin for neg./pos.
logic 2)
12 Vadj Output voltage adjust
13 +S Remote sensing
14 NC Not connected
Product Program
Input Voltage Output Voltage Output Current Output Power Part No.
1.2 V 12 A 14.4 W PMA 4118L S/SF
3.0 - 3.6 V 1.5 V 12 A 18.0 W PMA 4118H S/SF
1.8 V 12 A 21.6 W PMA 4218G S/SF
2.5 V 12 A 30.0 W PMA 4119 S/SF
1.2 V 12 A 14.4 W PMA 5118L S/SF
1.5 V 12 A 18.0 W PMA 5118H S/SF
4.5 - 5.5 V 1.8 V 12 A 21.6 W PMA 5218G S/SF
2.5 V 12 A 30.0 W PMA 5319 S/SF
3.3 V 12 A 39.6 W PMA 5310 S/SF
1.5 V 16 A 24.0 W PMA 8218H SF*
9.0 - 16.0 V 3.3 V 16 A 53.0 W PMA 8510 SF**
5.0 V 16 A 80.0 W PMA 8811 SF
S = Surface mount
F = Full- lter feature
* adjustable from 1.0V to 2.3V out
** adjustable from 2.3V to 3.6V out
20
8.5
35.2
31.5
14
7
6
Pin #1
ID mark
1
dimensions in mm
1) Applicable for 4000 and 5000 series.
Not connected (NC) for 8000 series.
2) Connect to -In for negative logic or leave open for
positive logic on RC pin.
12,3
15,1
2,8 (x3)
(15,4)
2,2 (x7)
(29)
3,5 (x8)3,5 (x6)
16,25
16,25
(36)
1,7 (x8)
2 (x6)
7,7
7,55
Pin 1