WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
CONSTANTCURRENTREGION Note.4
HLG-120-12 A
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE Note.6
CURRENT ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME Note.8
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR
EFFICIENCY (Typ.)
ACCURRENT
INPUT
INRUSHCURRENT( .)Typ
LEAKAGECURRENT
SAFETY STANDARDS Note.7
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERCURRENT Note.4
OVERVOLTAGE
OVERTEMPERATURE
Canbeadjusted byinternalpotentialmeterorthroughoutputcable
2500ms,50ms /115VAC;Btype2500ms,200msat95%load230VAC/115VACatfullload230VAC
16ms atfullload230VAC/115VAC
90~264VAC127~370VDC
47~63Hz
PF 0.95/230VACPF 0.98/115VACatfullloadandratedoutputvoltage PF 0.9at50~100%load
1.4A /115VAC0.6A /230VAC
COLDSTART 75A/230VAC
<0.75mA /240VAC
95~108%
Complianceto EN55015,EN55022(CISPR22)ClassB
CompliancetoEN61000-3-2ClassC( 50%load);EN61000-3-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61547,EN55024,heavyindustrylevel(surge4KV),criteria A
-40~+60 @fullload ;+70 @60%load(Refertoderatingcurve)
20~95%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes
192.2Khrsmin.MIL-HDBK-217F(25 )
220*68*38.8mm(L*W*H)
1.12Kg;12pcs/14.4Kg/0.76CUFT
120WSingleOutputSwitchingPowerSupply
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistor)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
5 years warranty (Note.10)
Suitable for dry / damp / wet locations
High efficiency up to 94%
Features :
HLG-120 series
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
EMICONDUCTION&RADIATION
SAFETY &
EMC
PROTECTION
100 10 (RTH2)
Protectiontype: Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
SHORTCIRCUIT
UL8750,EN61347-1,EN61347-2-13independent approved;DesignrefertoUL60950-1, TUVEN60950-1IP65orIP67
14~17V 18~21V 23~27V 28~34V 34~38V 41~46V 54~60V
47~53V 59~65V
92% 92% 93.5% 94% 94% 94% 94%94% 94%
2.5%
5~10A
2.0%
4~8A
1.0%
3~6A
1.0%
2.5~5A
1.0%
2~4A
1.0%
1.7~3.4A
1.0%
1.2~2.5A
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.5% 0.5% 0.5% 0.5% 0.5% 0.5%
1.0%
1.1~2.3A
0.5%
0.5%
1.0%
1.4~2.9A
0.5%
0.5%
12V
6~12V
15V
7.5~15V
20V
10~20V
24V
12~24V
30V
15~30V
36V
18~36V
48V
24~48V
10A 8A 6A 5A 4A 3.4A 2.5A
120W 120W 120W 120W 120W 122.4W 120W
150mVp-p 150mVp-p
13.5~17V
150mVp-p
17~22V
150mVp-p
22~27V
200mVp-p
27~33V
200mVp-p
33~40V
200mVp-p
43~53V10.8~13.5V
54V
27~54V
2.3A
124.2W
200mVp-p
49~58V
42V
21~42V
2.9A
121.8W
200mVp-p
38~46V
HLG-120-12
HLG-120-15
HLG-120-20
HLG-120-24
HLG-120-30
HLG-120-36
HLG-120-48 HLG-120-54
HLG-120-42
F M M
110 SELV
IP65 IP67
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistor.
Blank : IP67 rated. Cable for I/O connection.
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Shutdowno/pvoltagewithauto-recoveryorre-powerontorecovery
http://store.iiic.cc/
MechanicalSpecification CaseNo.994A Unit:mm
IP67rated.CableforI/Oconnection.
300 20
300 20
FG(Green/Yellow)
FG(Green/Yellow)
SJTW14AWG(1.5mm ) 2C
2
SJTW14AWG(1.5mm ) 2C
2
38.8
SJTW18AWG(0.75mm ) 3C
2
SJTW18AWG(0.75mm ) 3C
2
220
220
196
196
AC/L(Brown)
AC/L(Brown)
AC/N(Blue)
AC/N(Blue)
12
12
9.6
9.6
9.4
9.4 9.4
9.4 34.2
34.2
68
68
4.2 4PL
4.2 4PL
300 20
300 20
+V(Red)
+V(Red)
-V(Black)
-V(Black)
IP65rated.Outputvoltageandconstantcurrentlevelcanbeadjustedthroughinternalpotentialmeter.
(Canaccessbyremovingtherubberstopperonthecase.)
38.8
Vo
ADJ.
Io
ADJ.
120WSingleOutputSwitchingPowerSupply HLG-120 serie s
A Type:(HLG-120-_A)
Blank:(HLG-120)
FileName:HLG-120-SPEC2010-12-24
http://store.iiic.cc/
fosc:100KHz
DeratingCurve StaticCharacteristics
AMBIENTTEMPERATURE( )
LOAD(%)
-40 -25 -10 0 15 30 50 60 70
20
40
60
80
100
INPUTVOLTAGE(V)60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD(%)
(HORIZONTAL)
DIM+
(B Type)
DIM-
Fosc:100KHz
DETECTION
CIRCUIT
EMIFILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
BlockDiagram
300 20
38.8
SJTW18AWG(0.75mm ) 3C
2
220
196
12
9.6
9.4
9.4 34.2
68
4.2 4PL
300 20
+V(Red)
-V(Black)
FG(Green/Yellow)
AC/L(Brown)
AC/N(Blue)
SJTW18AWG(0.75mm ) 2C
2
SJTW14AWG(1.5mm ) 2C
2
O.L.P.
O.T.P.
DIM+(Blue)
DIM-(White)
PWM
60K
60%
60%
10K
1V 4V 7V2V 5V 8V3V 6V 9V 10V
10%
10%
20K
20%
20%
30K
30%
30%
40K
40%
40%
50K
50%
50%
70K
70%
70%
80K
80%
80%
90K 100K OPEN
OPEN
OPEN
90%
90%
100%
100%
Resistancevalue
Dimmingvalue
Percentageofratedcurrent
Percentageofratedcurrent
IP67rated.Outputconstantcurrentlevelcanbeadjustedthroughoutputcablebyconnectingaresistoror1~10Vdcor10VPWM
signalbetweenDIM+andDIM-.
Referenceresistancevalueforoutputcurrentadjustment(Typical)
PleaseDONOT connect "DIM-"to"-V".
1~10Vdimmingfunctionforoutputcurrentadjustment (Typical)
60%
60%
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
70%
70%
80%
80%
90%
90%
100%
100%
Dutyvalue
Percentageofratedcurrent
102%~108%
102%~108%
102%~108%
10VPWMsignalforoutputcurrentadjustment (Typical):Frequencyrange:100HZ~3KHz
120WSingleOutputSwitchingPowerSupply HLG-120 serie s
BType:(HLG-120-_B)
FileName:HLG-120-SPEC2010-12-24
http://store.iiic.cc/
65
67
69
71
73
75
77
79
81
83
85
87
89
91
93
95
97
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230VAC
110VAC
0.84
0.86
0.88
0.9
0.92
0.94
0.96
0.98
1
1.02
50% 60% 70% 80% 90% 100%
230VAC
110VAC
PowerFactorCharacteristic
Powerfactorwillbehigherthan0.9whenoutputloadingis50%orhigher.
EFFICIENCY vsLOAD(48VModel)
HLG-120seriespossesssuperiorworkingefficiencythatupto94%canbereachedinfieldapplications.
LOAD
EFFICIENCY (%) PF
LOAD
ConstantCurrentMode
TherearetwomajorkindsofLEDdrivemethod"directdrive"and"withLEDdriver".
A typicalLEDpowersupplymayeitherworkin"constantvoltagemode(CV)orconstantcurrentmode(CC)"todrivetheLEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
DRIVINGMETHODSOFLEDMODULE
TypicalLEDpowersupplyI-Vcurve
Vo(%)
100
50
50 100 Io (%)
Constant
Voltage area Constant
Current area
(A) (B)
120WSingleOutputSwitchingPowerSupply H L G - 120 series
FileName:HLG-120-SPEC2010-12-24
http://store.iiic.cc/
Directdriving:
Underdirectdriving,thepowersupplywillworkin"constantcurrentmode(CC)"andoutputvoltageofthepowersupplywillbeclampedbysumof
forwardvoltage(V )oftheLEDstrip.F
ThetotalforwardvoltageofseriesconnectingLEDsissuggestedfor60%~95%ofpowersupplyratedoutputvoltageduetoconcernofthebestPF
valueandefficiency.
AC
source I/P O/P
HLG-120
WithLEDdriver
Usingadditionaldriver,thepowersupplywillworkin"constantvoltagemode(CV)"andoutputvoltageofthepowersupplywillbekeptinratedvalue.
Inthisdrivemode,severaldesignissuesneedtobeconsidered:
1.OutputvoltageofPSUmustbehigherthantotalforwardvoltageofseriesconnectingLEDsby3Vminimum.
2.Inputcapacitor(Cin)ofLEDdrivercircuitshoulduse47uF~100uF(typ.)ofratingdependsontheoperatingfrequencyoftheLEDdriver.
Thehighertheoperatingfrequencyisused,thesmallervalueofCinshouldbechosen,andviceversa.
AC
source I/P O/P
ICCircuit
Cin Cout VF
R
L
HLG-120
~
~
~
~
3.DonotuseBtypewithLEDdriver.
DimmingconnectiondiagramforturningthelightingfixtureON/OFF:
UsingaswitchandrelaycanturnON/OFFthelightingfixture.
Usingthebuilt-indimmingfunctiononB-typemodelcan'tturnthelightingfixturetotallydark.Pleaserefertotheconnectionmethodbelowto
achieve0%brightnessofthelightingfixtureconnectingtotheLEDpowersupplyunit.
1.Outputconstantcurrentlevelcanbeadjustedthroughoutputcablebyconnectingaresistoror1~10Vdcor10VPWMsignalbetweenDIM+andDIM-.
2.TheLEDlightingfixturecanbeturnedON/OFFbytheswitch.
N FG L
LEDLighting
Relay
Blue
Brown
Green/
Yellow AC/L
AC/N
HLG-120
B Type
DIM+
DIM-
V(-)
V(+)
Blue
White
Black
Red
Switch Adjuster
0~100KOhmsresistance
1~10VDCVoltage
10VPWMSignal
DIMMINGOPERATION(forB-typeonly)
120WSingleOutputSwitchingPowerSupply HLG-120 serie s
FileName:HLG-120-SPEC2010-12-24
http://store.iiic.cc/
Waterproofconnector
WaterproofconnectorcanbeassembledontheoutputcableofHLG-120tooperateindry/wet/damporoutdoorenvironment.
HLG-120
I/P O/P
LEDLamp
AC
source
CableJoiner
PinConfiguration(Female) PinConfiguration(Female)
Size Size
M12 M15
4-PIN
5A/PIN
M12-04OrderNo. OrderNo.
10A max.SuitableCurrent SuitableCurrent
5-PIN
5A/PIN
M12-05
10A max.
2-PIN
12A/PIN
M15-02
12A max.
Uptofourwirescanbeconnectedthroughthiscablejoinerby
solderingorclampingbytools.
66
26 20
25
Suitablefor14AWG~22AWG
O/P Wires
LEDLamp
HLG-120
WATERPROOFCONNECTION
~
~
AC
source I/P
FG
C
BD AA
O/P
LEDCCdriver
ChassisofLEDLamp
CC
IC
HLG-120
A. Addacommonmodeferritechokeonoutputwirestoreducethecommonemissionbetween10M~300MHzperlightingEMIregulation.
B.ChassisofLEDlampandchassisofHLG-120ortheFGwireshouldbeconnectedtothesafetygroundtoreducetheEMInoise,includingtheconduction
andradiationemission.
C. TheadditionalX-Capanddischargeresistorcanreducethel conductionnoisebetween9K~1MHzperlightingEMIregulation.
D.L-Cfiltershould beaddedattheDCinputofLEDconstantcurrentdrivertoavoidthedifferentialemissionandhighfrequencynoisegeneratedbythe
CCdriver.
owfrequency
EMIDEBUGSUGGESTION
120WSingleOutputSwitchingPowerSupply HLG-120 serie s
FileName:HLG-120-SPEC2010-12-24
http://store.iiic.cc/