Part #
Mallory Sonalert Products Inc. SCH616CPR
Revision
Hazardous Location Alarm A
4411 South High School Road, Indianapolis, Indiana 46241 U.S.A Phone: (317) 612-1000 Fax: (317) 612-1010 www.mallory-sonalert.com
Specifications:
Sound level Category Medium Sound Level
Mode of Operation Chime
Voltage Rating 6 to 16 Vdc
Frequency 2900 Hz ± 500 Hz
Loudness 68 - 78 dB(A) min. @ 2 FT @ 6 - 16 Vdc
Current Draw 16 mA Max
Pulse Rate (PPS) 0.3 – 2.0
Storage Temperature -40°C to +85°C
Operating Temperature -30°C to +65°C
Weight (Typical) 2.1 oz (59 g)
Housing 6/6 Nylon, Color Black
Environmental Approvals NEMA 3R, 4X & 12; IP-66; CSA C22.2 No. 94;
Hazardous Loc. Class I, Div, II, Grps A, B, C & D
Panel Mounting Recommended hole size is 1.25” (31.75mm).
Threaded front will fit standard 30mm (1.181”) hole.
Mounting (see note B) Gasket (included with alarm) must be used to ensure
compliance to all Environmental Approvals.
Options For other options contact factory
Dimensions: Inches (mm) ROHS Compliant
UL Recognized