© 2008 IXYS All rights reserved 1 - 2
G
VWO 60
20080828a
IXYS reserves the right to change limits, test conditions and dimensions
Features
•
Thyristor controller for AC (circuit W3C
acc. to IEC) for mains requency
• Package with metal base plate
• Isolation voltage 3000 V~
• Planar passivated chips
• UL applied
• ¼" fast-on power terminals
Applications
• Switching and control of
three phase AC circuits
• Softstart AC motor controller
• Solid state switches
• Light and temperature control
Advantages
• Easy to mount with two screws
• Space and weight savings
• Improved temperature and power
cycling capability
• High power density
• Light weight and compact
VRSM VRRM Type
VDSM VDRM
VV
1200 1200 VWO 60-12io7
1400 1400 VWO 60-14io7
1600 1600 VWO 60-16io7
Symbol Conditions Maximum Ratings
IRMS TK = 85°C, 50 - 400 Hz (per phase) 60 A
ITRMS TVJ = TVJM 43 A
ITAVM TK = 85°C; (180° sine) 27 A
ITSM TVJ = 45°C; t = 10 ms (50 Hz), sine 550 A
VR = 0 t = 8.3 ms (60 Hz), sine 600 A
TVJ = TVJM t = 10 ms (50 Hz), sine 500 A
VR = 0 t = 8.3 ms (60 Hz), sine 550 A
I2tTVJ = 45°C t = 10 ms (50 Hz), sine 1520 A2s
VR = 0 t = 8.3 ms (60 Hz), sine 1520 A2s
TVJ = TVJM t = 10 ms (50 Hz), sine 1250 A2s
VR = 0 t = 8.3 ms (60 Hz), sine 1250 A2s
(di/dt)cr TVJ = TVJM repetitive, IT = 25 A 150 A/μs
f =50 Hz, tP =200 μs
VD = 2/3 VDRM
IG = 0.45 A non repetitive, IT = ITAVM 500 A/μs
diG/dt = 0.45 A/μs
(dv/dt)cr TVJ = TVJM;V
DR = 2/3 VDRM 1000 V/μs
RGK = ∞; method 1 (linear voltage rise)
PGM TVJ = TVJM tp = 30 μs10W
IT = ITAVM tp = 300 μs5W
PGAVM 0.5 W
VRGM 10 V
TVJ -40...+125 °C
TVJM 125 °C
Tstg -40...+125 °C
VISOL 50/60 Hz, RMS t = 1 min 2500 V~
IISOL ≤ 1 mA t = 1 s 3000 V~
MdMounting torque (M5) 5 ± 15 % Nm
(10-32 UNF) 44 ± 15 % lb.in.
Weight typ. 110 g
Data according to IEC 60747 refer to a single thyristor/diode unless otherwise stated.
Three Phase
AC Controller Modules
IRMS = 3x 60 A
VRRM = 1200-1600 V
Preliminary data
14 1 16 2 17 3
710 811 913