DATASHEET - M22-CLED-B Light element, LED, blue, front mount, 12-30VAC/DC, spring clamp connection Part no. Catalog No. Alternate Catalog No. EL-Nummer (Norway) Delivery program M22-CLED-B 218061 M22-CLED-BQ 4355775 Basic function accessories LED elements Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/Minden, Germany Connection technique Cage Clamp Fixing Front fixing Rated operational voltage Ue V 12 - 30 V AC/DC, 50/60 Hz Rated operational current Ie mA 8 - 15 Power consumption Pmax. W 0.26 Lifespan to EN 60064 at ta = +25 C tmean (AC) h 100000 Degree of Protection IP20 at 24 V Colour Blue Connection to SmartWire-DT Approval Connection technique no Cage Clamp Notes For indicator lights, illuminated pushbutton actuators, and illuminated selector switch actuators, the following applies: M22...-R only in combination with M22-LED...-R M22...-G only in combination with M22-LED...-G M22...-W only in combination with M22-LED...-W M22...-Y only in combination with M22-LED...-W M22...-B in combination with M22-LED...-W or M22-LED...-B Technical data General Standards IEC 60947-5-1 Operating torque (screw terminals) Nm 0.8 Degree of Protection IP20 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25 - +70 Storage C - 40 - + 80 03/02/2021 Eaton 218061 ED2021 V76.0 EN 1/3 Mounting position As required Mechanical shock resistance according to IEC 60068-2-27 Shock duration 11 ms, half-sinusoidal g > 30 Mechanical shock resistance g 30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 Terminal capacities mm Solid mm Stranded Rated impulse withstand voltage 2 2 0.75 - 2.5 mm 2 0.5 - 2.5 Uimp V AC 6000 Rated insulation voltage Ui V 500 Overvoltage category/pollution degree III/3 Rated operational current for specified heat dissipation In A 0 Heat dissipation per pole, current-dependent Pvid W 0 Equipment heat dissipation, current-dependent Pvid W 0 Static heat dissipation, non-current-dependent Pvs W 0.45 Heat dissipation capacity Pdiss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 70 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Contacts Indoor and protected outdoor installation Design verification as per IEC/EN 61439 Technical data for design verification IEC/EN 61439 design verification Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 7.0 Low-voltage industrial components (EG000017) / Lamp holder block for control circuit devices (EC000204) 03/02/2021 Eaton 218061 ED2021 V76.0 EN 2/3 Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Bulb socket block for command and alarm devices (ecl@ss10.0.1-27-37-12-09 [AKF027014]) Transformer integrated No With integrated voltage decreasing resistor No With light source Yes With integrated diode Yes Lamp holder None Rated voltage Ue at AC 50 Hz V 12 - 30 Rated voltage Ue at AC 60 Hz V 12 - 30 Rated voltage Ue at DC V 12 - 30 Voltage type for actuating AC/DC Lamp type LED Connection type auxiliary circuit Spring clamp connection Colour lamp Blue Type of fastening Front fastening Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Degree of Protection UL/CSA Type: - Approvals Dimensions A = 39 Pushbutton with M22-(C)K... Pushbutton with M22-(C) LED... + M22-XLED... Additional product information (links) IL04716002Z (AWA1160-1745) RMQ-Titan System IL04716002Z (AWA1160-1745) RMQ-Titan System 03/02/2021 https://es-assets.eaton.com/DOCUMENTATION/AWA_INSTRUCTIONS/IL04716002Z2020_09.pdf Eaton Industries GmbH http://www.eaton.eu (c) 02/2021 by Eaton Industries GmbH Eaton 218061 ED2021 V76.0 EN 3/3