Agilent U1610A/U1620A Handheld Digital Oscilloscope Data Sheet Features * 100/200 MHz bandwidth with two isolated channels * 5.7-inch VGA TFT LCD display with 3 selectable viewing modes (indoor, outdoor and night vision) * 2 Mpts memory depth and 2 GSa/s sampling rate allows detailed analysis of captured glitches * 10,000-count resolution on DMM display * Channel-to-channel isolation with CAT III 600 V safety ratings * Data logging capability to PC * 10 selectable languages on the User Interface (UI) system Indoor viewing mode Night vision viewing mode Retool your expectations in the world's first VGA display handheld oscilloscope with two isolated channels The U1610A/U1620A is the world's first handheld oscilloscope with a VGA display. This 100/200 MHz handheld oscilloscope offers a floating measurement capability with two CAT III 600 V isolated channels. With up to 2 GSa/s sampling rate and 2 Mpts memory depth, it captures more waveforms from signals such as pulse width modulated circuit, in rush, transient, and motor start up sequences. The benchtop-like display and dual window zoom allow you to easily identify problem areas and zoom in for more detailed analysis. Now, you can view signals in detail and detect glitches easily. 5.7-inch VGA display with 3 selectable viewing modes Visualizing electrical waveforms has never been in such clarity. Our U1610A/U1620A oscilloscope comes with a 5.7-inch VGA TFT LCD display that enables clear viewing of measurements on-site and on the field. With the option of up to three viewing modes, users can now view waveforms under all lighting conditions, including in indoor, outdoor or dark environments. All three viewing modes have predefined contrast levels for customized lighting conditions and optimized battery life. Indoor mode Outdoor mode Night vision mode The indoor mode has high contrast and brightness levels to clearly distinguish waveforms under an indoor light environment. Engineered with a VGA TFT LCD screen, users can now view the display across wide viewing angles for more efficient troubleshooting task. When performing field work in an outdoor environment, users can easily switch to this viewing mode via a set of accessible soft keys. This mode works in an anti-glare mechanism; it filters out excessive sunlight, hence reducing the risk of misreading or misinterpreting measurements. The night vision mode is tailored to be viewable under subdued lighting by enabling high contrast levels between the screen background and waveforms. With a single press of button, this mode is activated and the screen automatically adjusts with proper colour correction-creating clear contrasts between the waveforms against the dark environment. This mode is useful when measuring high speed signals, particularly in non-repetitive signals. Figure 1. Indoor mode for clear distinct readings Figure 2. Outdoor mode that is sunlight viewable Figure 3. Night vision mode for performing tasks in a poorly lit environment 2 Mpts memory depth and 2 GSa/s sampling rate allows detailed analysis of captured glitches A good oscilloscope must be accompanied with even better specifications for an in-depth analysis of captured glitches. With deep memory of 2 Mpts and sampling rate of 2 GSa/s, non-repeating signals can be captured over a wider time base. What's more, its dual window zoom feature allows you to work more productively by simultaneously viewing signals captured over a period of time and zooming into the most subtle details. Channel-to-channel isolation with CAT III 600 V safety ratings The U1610/U1620A extends the maximum input rating to cater for high voltage measurement and transient voltages which are recordable via a handheld oscilloscope. Equipped with the most robust isolation topology, technicians can now measure signals in the field and perform floating measurements. This type of isolation enables each channel to be individually isolated from one another and from other non-isolated system components. Up to 10 selectable languages programmed in the scope The U1610A/U1620A is programmed with up to 10 selectable languages (English, French, German, Italian, Spanish, Portuguese, Traditional and Simplified Chinese, Japanese and Korean) on the User Interface (UI) system and help menu. The diverse range of languages offered here gives users the choice to operate the unit in the language that they are most comfortable in. 2 Front panel description 5.7- inch VGA color display Function softkeys To perform functions displayed above each softkey Scope terminals USB interface connector and DC power inlet Acquisition and function controls To access the scope, meter, logger, system functions Directional keys Horizontal controls To control the sweep speed (sec/div) and horizontal position of the waveform. Use Menu/Zoom to zoom into waveforms Measurement softkeys To make quick measurements and place cursors on the waveform Vertical controls To set the vertical scaling (volt/div) and vertical offset Power on/off button Meter terminals Outdoor viewing mode as illustrated Figure 4. The U1620A as shown 3 Specifications U1610A Specification U1620A Vertical system Bandwidth (-3 dB) 1 100 MHz 200 MHz 4% of full scale DC vertical gain accuracy 1 Full scale is equivalent to 8 div Dual cursor accuracy {DC vertical gain accuracy + 0.4% full scale (~1 least significant bit (LSB)} 1 {4% full scale 0.4% full scale (~1 LSB)} Characteristic Acquisition Maximum Sampling Rate Single Chanel Operation 1 GSa/s interleave 2 GSa/s interleave Dual Channel Operation 500 MS/s each channel 1 GS/s each channel Maximum Recording Length Single Chanel Operation 120 Kpts interleave Dual Channel Operation 60 Kpts each channel Vertical resolution 2 Mpts interleave 1 Mpts each channel 8 bits Peak detection > 10 ns Average Selectable from 2 to 8192 in powers-of-2 increments Filter > 5 ns 10 kHz and 20 MHz bandwidth limiters Interpolation (Sin x)/x Vertical system Analog channels Channel 1 and Channel 2 simultaneous acquisition Calculated rise time 3.50 ns typical Vertical scale Maximum input 1.75 ns typical 2 mV/div to 50 V/div CAT III 600 Vrms (with 10:1 probe) ! CAT III 300 Vrms (direct / 1:1 probe) Offset (position) range 4 div Dynamic range 8 div Input impedance 1 M 1% 22 pF 3 Pf Coupling DC, AC Bandwidth limit Channel-to-channel isolation (with channels at the same V/div) Probes 10 kHz and 20 MHz (selectable) CAT III 600 Vrms ! U1560-60002 1:1 passive probe U1561-60002 10:1 passive probe U1562-60002 100:1 passive probe Probe attenuation factors 1x, 10x, 100x Probe compensation output 5 Vpp, 1 kHz Noise peak-to-peak (typical) 5% of full scale or 8 mVpp, whichever is greater DC vertical offset (position) accuracy Single cursor accuracy 0.1 div 2 mV 1.6% offset value {DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 least significant bit (LSB)} {4% full scale 0.1 div 2 mV 1.6% offset value + 0.2% full scale (~1/2 LSB)} 4 Specifications (continued) U1610A U1620A Range 5 ns/div to 50 s/div 2 ns/div to 50 s/div Resolution 100 ps for 5 ns/div 40 ps for 2 ns/div Characteristic (continued) Horizontal system Timebase accuracy 25 ppm Reference position Left, center, right Delay range (pre-trigger) Delay range (post-trigger) Delay resolution Delay time measurement accuracy 1 screen width or 120 s (whichever less) 1 screen width or 1 ms (whichever less) 50 ms to 500 s 20 ms to 500 s 100 ps for 5 ns/div 40 ps for 2 ns/div Same channel: 0.0025% reading 0.17% screen width 60 ps Channel-to-channel: 0.0025% reading 0.17% screen width 120 ps Modes Main, zoom, XY, roll Horizontal pan and zoom Dual window zoom Trigger system Sources Channel 1, Channel 2, External Modes Normal, Single, Auto Types Edge, Glitch, TV, Nth Edge, CAN, LIN Autoscale Finds or displays active channels, sets the edge trigger type on the highest numbered channel, and sets the vertical sensitivity on the scope channel timebase to display ~2 periods Requires > 10 mVpp minimum voltage, 0.5% duty cycle, and > 50 Hz minimum frequency Holdoff time 60 ns to 10 s Range 6 div from center of screen Sensitivity 10 mV/div: 0.5 div < 10 mV/div: greater of 1 div or 5 mV Trigger level accuracy Coupling modes 0.6 div AC (~10 Hz), DC, LF-Reject (~35 kHz), HF-Reject (~35 kHz) External trigger * Input impedance * Maximum input 1 M 10 pF CAT III 300 Vrms ! * Range DC coupling: trigger level 5 V * Bandwidth 100 kHz Measurement Automatic measurements Delay, duty cycle (+/-), fall/rise time, frequency, period, phase shift, T-max, T-min, width (+/-), amplitude, average, base, crest, cycle mean, maximum, minimum, overshoot, peak-to-peak, preshoot, standard deviation, top, Vrms (AC/DC), active/apparent/reactive power, power factor, AC current (with U1583B/1146A), DC current (with 1146A) Waveform math functions CH1 + CH2, CH1 - CH2, CH2 - CH1, CH1 x CH2, CH1/CH2, CH2/CH1, d/dt (CH1), d/dt (CH2), (CH1)dt, (CH2)dt, FFT Cursors Delta V: Voltage difference between cursors Delta T: Time difference between cursors FFT points FFT windows 1024 Rectangular, Hamming, Hanning, Blackman-Harris, Flattop 5 Specifications (continued) Characteristic (continued) U1610A U1620A Display system Display Resolution Control 5.7" TFT LCD VGA Color (outdoor readable) VGA (screen area): 640 vertical by 480 horizontal Vectors on/off, sin x/x interpolation on/off, infinite persistence on/off, backlight intensity, color scheme, clear display Real-time clock Date and time (adjustable) Language Built-in help system 10 languages (selectable) Functional quick help displayed by pressing the [Help] button Storage system Save/recall (non-volatile) Storage mode 10 setups and waveforms can be saved and recalled internally USB 2.0 full speed host port (Support up to 4GB USB drive) Image formats: .bmp (8-bit, 24-bit) and .png (24-bit) Data format: .csv I/O Printer languages and standards USB 2.0 full-speed host, USB 2.0 full-speed client PCL 3 GUI, PCL 5 Enhanced, PCL 5 Color, PCL 6 1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and within 23 10 C of last calibration temperature. 6 Maximum input voltages and channel isolation U1610A and U1620A Maximum input voltages Input CH1 and CH2 direct (1:1 probe) 300 Vrms CAT III Input CH1 and CH2 (1:10 probe) 600 Vrms CAT III, 1000 Vrms1 CAT II Input CH1 and CH2 (1:100 probe) 600 Vrms1 CAT III, 1000 Vrms1 CAT II, 3540 Vrms1 CAT I 1 Meter input 600 Vrms CAT III, 1000 Vrms CAT II Scope input 300 Vrms CAT III Voltage ratings Vrms 50-60 Hz (AC sine wave), VDC (DC applications) Channel isolation From any terminal to earth ground 600 Vrms CAT III 1. Refer to the respective probe's manual for more information on the specification Voltage (Vrms) 1000 100 CAT lll 600 CAT ll 1000 10 1 0.01 0.1 1 10 100 Frequency (KHz) Figure 5. Maximum safety voltage for scope reference to earth Voltage (Vrms) 1000 100 Max input voltage 10 1 0.0001 0.001 0.01 0.1 1 Frequency (MHz) 10 100 Figure 6. Maximum input voltage 7 1000 Digital multimeter specifications * Accuracy is given as (% of reading + counts of least significant digit) at 23 5 C, with relative humidity < 80 RH. * AC V specifications are AC coupled, true RMS and are valid from 5% to 100% of range. * Temperature coefficient is given as 0.1 x (specified accuracy) / C (from 0 to 18 C or 28 to 50 C). * Common mode rejection ratio (CMRR) is > 90 dB at DC, 50/60 Hz 0.1% (1 k unbalanced). * Normal mode rejection ratio (NMRR) is > 60 dB at 50/60 Hz 0.1%. Maximum reading Voltage 1 10,000 counts with automatic polarity indication CAT II 1000 V or CAT III 600 V Function DC V AC V AC + DC V Range Resolution Accuracy 100.00 mV 2 0.01 mV 0.1% + 5 1000.0 mV 0.1 mV 0.09% + 5 10.000 V 0.001 V 100.00 V 0.01 V 1000.0 V 3 0.1 V 0.15% + 5 100.00 mV 0.01 mV 1% + 5 (40 Hz to 2 kHz) 1000.0 mV 0.1 mV 10.000 V 100.00 V 0.001 V 0.01V 1000.0 V 3 0.1 V 100.00 mV 2 0.01 mV 1000.0 mV 0.1 mV 10.000 V 100.00 V 0.001 V 0.01 V 1000.00 V 3 0.1 V 1V 0.001 V Diode 4 Input impedance (nominal) Test current 0.09% + 2 > 1 G 11.11 M 10.10 M 10.01 M > 1 G 1% + 5 (40 to 500 Hz) 2% + 5 (500 Hz to 1 kHz) 1% + 5 (40 to 500 Hz) 1% + 5 (500 Hz to 1 kHz) 10.00 M 2% + 5 (1 to 2 kHz) 1% + 5 (40 to 500 Hz) 1% + 5 (500 Hz to 1 kHz) 1.1% + 5 (40 Hz to 2 kHz) > 1 G 1.1% + 10 (40 to 500 Hz) 2.1% + 10 (500 Hz to 1 kHz) 1.1% + 7 (40 to 500 Hz) 1.1% + 7 (500 Hz to 1 kHz) 10.00 M 2% + 5 (1 to 2 kHz) 1.2% + 10 (40 to 500 Hz) 1.2% + 10 (500 Hz to 1 kHz) 0.3% + 2 ~0.5 mA Beeper < ~50 mV, single tone for normal forward-biased diode or semiconductor junction of 0.3 V reading 0.8 V 5 Overload protection: 1000 Vrms for short circuit with < 0.3 A Open voltage: < +2.8 VDC 1. Only allowed to measure up to CAT III 600 V if referring to GND. 2. In an open connection, the reading shown on the display is noise pickup due to the high input impedance at the input terminal. 3. Only allowed for floating voltage. 4. Denotes typical specifications, all others are warranted. 5. Denotes characteristics. 6. The accuracy is specified after the Null function is used to subtract the test lead resistance and thermal effect. 7. RH is specified for < 60%. The temperature coefficient is 0.15 x specified accuracy as > 50 M. 8. The accuracy is based on film capacitors or better and uses the Relative mode for residual values. NOTE: Agilent recommends using the U1586B temperature adapter for temperature measurement. Refer to http://cp.literature.agilent.com/litweb/pdf/U1586-90101.pdf for more information on the U1586B specifications. 8 Digital multimeter specifications (continued) Maximum reading Voltage 1 10,000 counts with automatic polarity indication CAT II 1000 V or CAT III 600 V Function Range Resolution Instant continuity 4 Resistance Capacitance Frequency 4 Input impedance (nominal) Test current Accuracy Continuous beep when resistance < 10 5 1000.00 6 0.1 10.000 k 0.001 k 6 0.5 mA 50 A 0.3% + 3 100.00 k 0.01 k 1000.0 k 0.1 k 4.91 A 10.000 M 0.001 M 0.8% + 3 112 nA 100.00 M 7 0.01 M 1.5% + 3 112 nA 447 nA 1000.0 nF 0.1 nF 10.000 F 0.001 F 100.00 F 0.01 F 1000.0 F 0.1 F 10.000 mF 0.001 mF 100.00 Hz 0.01 Hz 1000.0 Hz 0.1 Hz 10.000 kHz 0.001 kHz 100.00 kHz 0.01 kHz 1000.0 kHz 0.1 kHz 1.2% + 4 8 2% + 4 8 0.03% + 3 1. Only allowed to measure up to CAT III 600 V if referring to GND. 2. In an open connection, the reading shown on the display is noise pickup due to the high input impedance at the input terminal. 3. Only allowed for floating voltage. 4. Denotes typical specifications, all others are warranted. 5. Denotes characteristics. 6. The accuracy is specified after the Null function is used to subtract the test lead resistance and thermal effect. 7. RH is specified for < 60%. The temperature coefficient is 0.15 x specified accuracy as > 50 M. 8. The accuracy is based on film capacitors or better and uses the Relative mode for residual values. NOTE: Agilent recommends using the U1586B temperature adapter for temperature measurement. Refer to http://cp.literature.agilent.com/litweb/pdf/U1586-90101.pdf for more information on the U1586B specifications. Data logger specifications Scope and meter logger Range 1 s/div - 86400 s/div (1 day/div) Recording time span 8 days Memory depth Recording mode 691200 points Continuous (Range will change according to the time elapsed) Sampling rate 1 sample/s 9 General specifications Power supply Power adapter Line voltage range: 50/60 Hz, 100 to 240 VAC, 1.6 A Output voltage: 15 VDC, 4 A Installation Category II Battery Li-Ion rechargeable battery pack, 10.8 V Operating time: Up to 3 hours Operating environment Temperature 0 to 50 C (with battery only) 0 to 40 C (with power adapter) Humidity 0 to 80% RH (0 to 35 C) 0 to 50% RH (35 to 40/50 C) Altitude up to 2000 m Pollution degree 2 Storage compliance Temperature -20 to 70 C Humidity 0 to 80% RH Altitude up to 15000 m Shock Tested to IEC 60068-2-27 Vibration Tested to IEC 60068-2-6, IEC 60068-2-64 Safety compliance IEC 61010-1:2001/EN 61010-1:2001 Canada: CAN/CSA-C22.2 No. 61010-1-04 USA: ANSI/UL 61010-1:2004 EMC compliance IEC 61326-1:2005/EN 61326-1:2006 Australia/New Zealand: AS/NZS CISPR 11:2004 Canada: ICES/NMB-001:ISSUE 4, June 2006 IP rating IP 41 ingress protection according to IEC 60529 Dimensions (W x H x D) 183 x 270 x 65 mm Weight < 2.5 kg Warranty 3 years for main unit 3 months for standard shipped accessories unless otherwise stated 10 Ordering information Standard shipped items * Quick start guide, power adapter, Li-Ion battery pack, USB cable, test lead, 10:1 probe (2 sets), Certificate of Calibration (CoC). Recommended accessories Item Item 1146B U1562A Probe - 100 kHz, 100A AC/DC current probe Scope probe - X100 CAT III 600 V U1161A Test lead kit, extended U1572A Li Polymer battery pack U1162A U1573A Alligator clip Desktop charger and Li Polymer battery pack U1163A Grabbers, SMT U1574A U1164A AC/DC adapter Test probes, fine tip U1575A Desktop charger U1168B Test lead kit U1577A USB cable U1169A U1580A Test probe leads (with 19-mm tips and 4-mm tips) DMM terminal test lead set U1176A LED flash light U1554A U1583B Probe tip, 1000 V CAT Ii, 600 V CAT Iii AC current clamp U1560A Temperature module Scope probe - X1 CAT III 300 V U1591A U1586B Soft carrying case U1561A Scope probe - X10 CAT III 600 V 11 www.agilent.com www.agilent.com/find/handheldscope www.agilent.com/find/U1600 myAgilent myAgilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.agilent.com/find/ThreeYearWarranty Beyond product specification, changing the ownership experience. Agilent is the only test and measurement company that offers three-year warranty on all instruments, worldwide. Agilent Assurance Plans www.agilent.com/find/AssurancePlans Five years of protection and no budgetary surprises to ensure your instruments are operating to specifications and you can continually rely on accurate measurements. www.agilent.com/quality Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent's measurement expertise and product breadth, combined with channel partner convenience. For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom 32 (0) 2 404 93 40 45 45 80 12 15 358 (0) 10 855 2100 0825 010 700* *0.125 /minute 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP-09-27-13) Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2013 Published in USA, December 2, 2013 5990-9523EN