POWER LPT60 Series 60 Watts Data Sheet Total Power: 60 - 80 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc # of Outputs: Triple SPECIAL FEATURES Universal input 3" x 5" footprint Remote sense on main output Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available RoHS compliant SAFETY UL: 60950 E132002 cUL : 60950 LR53982C NEMKO: EN 60950/EMKO-TUE P95100123 (74-sec) 203 CB: Certificate and report 1518, 1519, 1520 CE: Mark (LVD) Electrical Specifications Input Input range 85 - 264 Vac 120 - 300 Vdc Frequency 47 - 440 Hz Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25 C Input current 1.5 A max. (RMS) @ 115 Vac Efficiency 70% typical at full load (60% for LPT61) EMI FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 60 W for convection (LPT61, 35 W); 80 W with 30CFW forced air (LPT61, 55 W) Cross regulation 2% on output 1; 5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time 20 ms @ 40 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating Overvoltage protection 5.7 to 6.7 Vdc on the main output LPT41: 3.6 to 4.6 Vdc Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. LPT60 Series Data Sheet Environmental Specifications Operating temperature 0 C to 50 C ambient derate each output at 2.5% per degree from 50 to 70 C, -20 C startup Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational Storage temperature -40 C to 85 C Temperature coefficient .04% per C MTBF demonstrated >550,000 hours at full load and 25 C ambient conditions Ordering Information 1. 2. 3. 4. Peak Load1 Regulation2 Ripple P/P (PARD)3 8.5 A 3.0 A 1.0 A 9.5 A 3.3 A 1A 2% 2% 5% 50 mV 50 mV 120 mV 7A 3A 0.7 A 8A 3.5 A 1A 10 A 6A 1.5 A 2% 5% 5% 50 mV 120 mV 120 mV 0.7 A 0.3 A 0A 7A 2.8 A 0.7 A 8A 3.3 A 1A 10 A 4A 1.5 A 2% 5% 5% 50 mV 150 mV 150 mV +5 V +12 V -5 V 0.7 A 0.3 A 0A 7A 3A 0.7 A 8A 3.5 A 1A 10 A 6A 1.5 A 2% 5% 5% 50 mV 120 mV 50 mV +5 V +24 V +12 V 0.7 A 0.1 A 0A 7A 1.5 A 0.7 A 8A 2.0 A 1A 10 A 3A 1.5 A 2% 7% 5% 50 mV 240 mV 120 mV Model Number Output Voltage Minimum Load Maximum Load with Maximum Load with Convection Cooling 30CFM Forced Air LPT61 +3.3 V +5 V +12 V 0.7 A 0A 0A 5A 2.5 A 0.5 A LPT62 +5 V +12 V -12 V 0.7 A 0.3 A 0A LPT63 +5 V +15 V -15 V LPT64 LPT65 Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges. Minimum Loads are required. 5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Power Derating Curve 80W 30 CFM Forced Air Cooling 60W Output Power (Watts) 40W 20W Natural Convection Cooling 40W 30W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C LPT60 Series Data Sheet Mechanical Drawing 0.22" (5.6) M2 GND M1 + SK201 _ 3.00" (76.2) 2.55" (64.8) 3 1 2 3 4 5 6 SK 1 N 1 Remote Sense Connector Voltage Adj. Pot SK 2 L 4.56" (115.8) 0.22" (5.6) 0.15" (4) DIA (4 places) 5.00" (127) 1.69" (42.9) 0.12" (3) Pin Assignments Mating Connectors Connector LPT61 LPT62 LPT63 LPT64 LPT65 SK1-1 Line Line Line Line Line SK1-3 Neutral Neutral Neutral Neutral Neutral SK2-1 5V +12V +15V +12V +24V SK2-2 3.3V +5V +5V +5V +5V SK2-3 3.3V +5V +5V +5V +5V SK2-4 Common Common Common Common Common SK2-5 Common Common Common Common Common SK2-6 +12V -12V -15V -5V +12V SK201-1 +Sense +Sense +Sense +Sense +Sense SK201-2 -Sense -Sense -Sense -Sense -Sense AC Input Molex 09-50-8031 (USA) 09-93-0300(UK) PINS: 08-58-0111 DC Outputs Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Remote Sense Molex 22-01-2025 PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. 2. 3. 4. 5. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 Vac input, 25 C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.75lbs/0.34kg WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. (c) 2016 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com LPT60 Series-DS 22Mar2016