Fiber Sensor Guide Book 2014.06 panasonic.net/id/pidsx/global GENERAL TERMS AND CONDITIONS Please read this document carefully with respect to our product warranty policy before using our Panasonic Industrial Devices SUNX products ("Products"). If you have any questions or comments regarding do's and don'ts of the Products, please consult your local Panasonic Industrial Devices SUNX authorized dealer for the correct use and application of the Products. 1. PRODUCT MODIFICATION & DISCONTINUANCE: Panasonic Industrial Devices SUNX expressly reserves the right to modify, including the right to discontinue, any of the Products, prior to their order, from time to time without notice. 2. WARRANTIES: (1) Subject to the exclusions stated in 3 (EXCLUSIONS) herein below, Panasonic Industrial Devices SUNX warrants the Products to be free of defects in material and workmanship for a period of one (1) year from the date of shipment under normal usage in environments commonly found in manufacturing industry. (2) Any Products found to be defective must be shipped to Panasonic Industrial Devices SUNX with all shipping costs paid by Purchaser or offered to Panasonic Industrial Devices SUNX for inspection and examination. Upon examination by Panasonic Industrial Devices SUNX, Panasonic Industrial Devices SUNX will, at its sole discretion, repair or replace at no charge, or refund the purchase price of, any Products found to be defective. 3. EXCLUSIONS (1) This warranty does not apply to defects resulting from any cause: (i) which was due to abuse, misuse, mishandling, improper installation, improper interfacing, or improper repair by Purchaser; (ii) which was due to unauthorized modification by Purchaser, in part or in whole, whether in structure, performance or specification; (iii) which was not discoverable by a person with the state-of-the-art scientific and technical knowledge at the time of manufacture; (iv) which was due to an operation or use by Purchaser outside of the limits of operation or environment specified by Panasonic Industrial Devices SUNX; (v) which was due to Force Majeure; and (vi) which was due to any use or application expressly discouraged by Panasonic Industrial Devices SUNX in 5 (CAUTIONS FOR SAFE USE) hereunder. (2) This warranty extends only to the first purchaser for application, and is not transferable to any person or entity which purchased from such purchaser for application. (3) The performance data presented in this catalogue is only for guidance and shall not constitute any performance warranty by Panasonic Industrial Devices SUNX. 4. DISCLAIMERS (1) Panasonic Industrial Devices SUNX's sole obligation and liability under this warranty is limited to the repair or replacement, or refund of the purchase price, of a defective Product, at Panasonic Industrial Devices SUNX's option. (2) THE REPAIR, REPLACEMENT, OR REFUND IS THE EXCLUSIVE REMEDY OF THE PURCHASER, AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE HEREBY EXPRESSLY DISCLAIMED. IN NO EVENT SHALL PANASONIC INDUSTRIAL DEVICES SUNX AND ITS AFFILIATED ENTITIES BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCTS, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR ANY DAMANGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS. 5. CAUTIONS FOR SAFE USE (1) The applications shown in this catalogue are only suggestions, and it is Purchaser's sole responsibility to ascertain the fitness and suitability of the Products for any particular application, as well as to abide by Purchaser's applicable local laws and regulations, if any. (2) Never use the Products NOT rated or designated as "SAFETY SENSOR" in any application involving risk to life or property. When such a use is made by Purchaser, such Purchaser shall indemnify and hold harmless Panasonic Industrial Devices SUNX from any liability or damage whatsoever arising out of or in relation to such use. (3) In incorporating the Products to any equipment, facilities or systems, it is highly recommended to employ fail-safe designs, including but not limited to a redundant design, flame propagation prevention design, and malfunction prevention design so as not to cause any risk of bodily injury, fire accident, or social damage due to any failure of such equipment, facilities or systems. (4) The Products are each intended for use only in environments commonly found in manufacturing industry, and, unless expressly allowed in this catalogue, specification or otherwise, shall not be used in, or incorporated into, any equipment, facilities or systems, such as those: (a) which are used for the protection of human life or body parts; (b) which are used outdoors or in environments subject to any likelihood of chemical contamination or electromagnetic influence; (c) which are likely to be used beyond the limits of operations or environments specified by Panasonic Industrial Devices SUNX in this catalogue or otherwise; (d) which may cause risk to life or property, such as nuclear energy control equipment, transportation equipment (whether on rail or land, or in air or at sea), and medical equipment; (e) which are operated continuously each day for 24 hours; and (f) which otherwise require a high level of safety performance similar to that required in those equipment, facilities or systems as listed in (a) through (e) above. 6. EXPORT CONTROL LAWS In some jurisdictions, the Products may be subject to local export laws and regulations. If any diversion or re-export is to be made, Purchaser is advised to abide by such local export laws and regulations, if any, at its own responsibility. 7. PURCHASER'S TRASFER OBLIGATIONS If Purchaser resell or deliver the Products to a third party, Purchaser must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information of any kind provided to Purchaser by Panasonic Industrial Devices SUNX or its authorized local representative from time to time regarding the Products. INDEX Fiber Selection Guide Choose by model Choose by shape/application 3 How to read Model No. 4 Earlier model comparison table 6 New Product Introduction Tough Fiber Fibers 2 8 Super Quality 10 Threaded Type 12 Square Head Type 14 Cylindrical Type 16 Sleeve 18 Flat Type 20 Small Spot 22 Narrow Beam 24 Wide Beam 25 Convergent Reflective Type 26 Retroreflective Type 27 Chemical / Oil-resistant 28 Heat-resistant 30 Vacuum-resistant 32 Liquid Leak / Liquid Detection 34 Fiber Options 42 Semi-custom Fibers 46 Fiber Dimensions Amplifiers INDEX Thru-beam Type 48 Retroreflective Type 55 Reflective Type 56 Others 66 FX-500 series Ver.2 70 FX-100 series 98 112 2 New product introduction Tough Fiber Fiber Selection Guide Choose by model Thru-beam type Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Retroreflective type Page Model No. FT-140 FT-30 FT-31 FT-31S FT-31W FT-40 FT-42 FT-42S FT-42W FT-43 FT-45X FT-A11 FT-A11W FT-A32 FT-A32W FT-AL05 FT-E13 FT-E23 FT-F93 FT-H13-FM2 FT-H20-J20-S FT-H20-J30-S FT-H20-J50-S FT-H20-M1 FT-H20-VJ50-S FT-H20-VJ80-S FT-H20W-M1 FT-H30-M1V-S FT-H35-M2 FT-H35-M2S6 FT-HL80Y FT-KS40 FT-KV26 FT-KV40 FT-KV40W FT-L80Y FT-R31 FT-R40 FT-R41W FT-R42W FT-R43 FT-R44Y FT-R60Y FT-S11 FT-S20 FT-S21 FT-S21W FT-S30 FT-S31W FT-S32 FT-V23 FT-V24W FT-V25 FT-V30 FT-V40 FT-V80Y FT-Z20HBW FT-Z20W Page Sensing range Dimensions Specifications P.12 P.11 P.12 P.19 P.12 P.11 P.12 P.19 P.48 P.12 Model No. FT-Z30 FT-Z30E FT-Z30EW FT-Z30H FT-Z30HW FT-Z30W FT-Z40HBW FT-Z40W FT-Z802Y Sensing range Dimensions Specifications P.53 P.20 P.35 P.30 P.50 P.32 P.30 P.29 P.24 P.51 P.15 P.15/P.29 P.16 P.11 P.52 P.11 P.16 P.19 P.20 P.24/P.27 P.55 P.29 Page Model No. P.16/P.19 P.16 P.29 FR-KZ22E FR-KZ50E FR-KZ50H FR-Z50HW Sensing range Dimensions Specifications P.54 P.49 P.16 Model No. Reflective type P.25 P.29 P.15 P.12 Page P.53 FD-30 FD-31 FD-31W FD-32G FD-32GX FD-40 FD-41 FD-41S FD-41SW FD-41W FD-42G FD-42GW FD-60 FD-61 FD-61G FD-61S FD-61W FD-62 FD-64X FD-A16 FD-AL11 FD-E13 FD-E23 FD-EG30 FD-EG30S FD-EG31 FD-F4 FD-F41 FD-F41Y FD-F71 FD-F8Y FD-FA93 FD-H13-FM2 FD-H18-L31 FD-H20-21 FD-H20-M1 FD-H25-L43 FD-H25-L45 Page Sensing range Dimensions Specifications P.11 P.13 P.13/P.23 P.11 P.13 P.56 P.19 P.13 P.13/P.23 P.11 P.13 P.57 P.19 P.13 P.25 P.58 P.17/P.19 P.13/P.23 P.19 P.13/P.23 P.59 P.35 P.31 P.60 Model No. FD-H30-KZ1V-S FD-H30-L32 FD-H30-L32V-S FD-H35-20S FD-H35-M2 FD-H35-M2S6 FD-HF40Y FD-L10 FD-L11 FD-L12W FD-L20H FD-L21 FD-L21W FD-L22A FD-L23 FD-L30A FD-L31A FD-L32H FD-R31G FD-R32EG FD-R33EG FD-R34EG FD-R41 FD-R60 FD-R61Y FD-S21 FD-S30 FD-S31 FD-S32 FD-S32W FD-S33GW FD-S60Y FD-V30 FD-V30W FD-V50 FD-Z20HBW FD-Z20W FD-Z40HBW FD-Z40W FD-Z50HW Sensing range Dimensions Specifications P.32 P.31 P.32 P.61 P.31 P.35 P.26 P.62 P.15/P.23 P.63 P.15 P.13 P.15/P.29 P.17 P.11 P.17 P.64 P.29 P.19 P.21 P.24 P.65 3 Fiber Selection Guide New product introduction Choose by shape Tough Fiber Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type S tandard type which is mounted using nuts. Installed cleanly on the side of a conveyor belt. H as a slender shape that is mounted using set screws. S uitable for sensing in narrow locations and sensing minute objects. hin and rectangular T shape. Installed directly in narrow locations with screws. Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table P.12 P.14 P.16 P.18 P.20 Fibers Super Quality Threaded Type Choose by beam shape Square Head Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type S enses minute objects using a spot lens. N ot easily affected by surrounding obstacles. S enses in the beam band without missing a work. S enses in the limited range only. I deal for sensing transparent objects Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type P.22 Choose by quality P.24 P.25 P.26 P.27 Chemical / Oilresistant Heatresistant Vacuumresistant Choose by environment / performance Super Quality Chemical / Oil-resistant Heat-resistant Vacuum-resistant Liquid Leak / Liquid Detection The variance of beam intensity and beam axis is extremely small. V arious kinds of liquids can be detected due to the fluorine contained resin case W ithstands at -60 C -76 F to 350 C 662 F U sable in hightemperatures of 300 C 572 F and vacuum C orresponds to various liquid events. Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type P.10 P.28 P.30 P.32 P.34 Fiber sensor amplifiers guidance Digital fiber sensor FX-500 series Ver. 2 Amplifiers S uper functionality, yet, economical price P.70 Reflective Type Others Digital fiber sensor FX-100 series A t the industry's leading edge Retroreflective Type FX-500 series FX-100 series P.98 INDEX 4 New product introduction Tough Fiber Fiber Selection Guide How to read Model No. Applies to the fiber in (P.10~P.35) Fiber Selection Guide Model Choose by shape/ application How to read Model No F Series Name - *1 Type *1 Shape, etc. Functions / Features *1: Excluding liquid leak / liquid detection fiber Earlier models comparison table Fibers Super Quality Threaded Type Symbol Details T Thru-beam type D Reflective type R Retroreflective type Symbol None G S H E HB A Square Head Type Cylindrical Type Details General-purpose Coaxial reflective Sleeve Top sensing * Side sensing * Top sensing + Bent * Alignment * is for Flat type (Z and KZ) only Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Symbol None Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection R S KS Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type V KV E EG Z Reflective Type Others KZ A Amplifiers FX-500 series FX-100 series AL L F INDEX Lead No. 3 4 Treaded type 6 14 4 Elbow or square head 6 1 2 Cylindrical type 3 Narrow beam 4 2 3 Side-view 4 5 4 Narrow beam / Side-view 2 1 Ultra small diameter 2 Coaxial 3 2 3 Flat type 4 5 2 Narrow beam 5 3 Wide beam 1 1 Array 0 1 2 Convergent reflective type 3 9 Liquid leak / Liquid detection 7 Details Details M3 M4 M6 M14 M4 M6 o1 mm o1.5 mm o2.5 or o3 mm o3.7 mm o2 mm o2.5 or o3 mm o4 mm o5 mm o4 mm 1.5 x 2 mm Fiber o0.125 mm Fiber o0.25 mm M3 Thickness 2 mm Thickness 3 mm Thickness 3.5 mm Thickness 5.2 mm Thickness 2.2 mm Thickness 5.2 mm Sensing width 32 mm Sensing width 10 to 19 mm Sensing width 11.1 mm Sensing width 5.5 mm Sensing range 0 to 10 mm (STD) Sensing range 11 to 30 mm (STD) Sensing range 31mm or more (STD) Mountable on pipe Liquid leak Symbol None W X Y Details General-purpose Sharp bending Stainless-jacketed Chemical-resistant 5 6 New product introduction Tough Fiber Fiber Selection Guide specification of new fiber may be changed from that Earlier Models Comparison TableThe of old one. Please confirm the specification before use. Thru-beam type Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Old fiber New fiber Model No. Model No. FT-A30 FT-A32 FT-A8 FT-A11 FT-AFM2 FT-AFM2E FT-B8 FT-43 FT-E12 FT-E13 Super Quality FT-E22 FT-E23 FT-F902 FT-F93 FT-FM10L FT-140 FT-FM2 FT-42 Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others FT-FM2S FT-FM2S4 FX-500 series FX-100 series INDEX FT-42S P.25 P.12 P.16/P.19 P.19 FT-KV8 FT-KV40 FT-NFM2 FT-31 P.12 FT-31S P.19 FT-S21 FT-P40 FT-31 FT-P60 FT-P80 FT-42 P.49 P.48 FT-KV26 FT-P2 P.48 P.12 FT-KV1 FT-NFM2S4 P.49 P.35 FT-KS40 FT-NFM2S Old fiber New fiber Model No. Model No. FT-WKV8 FT-K8 P.24 P.16 P.12 P.51 P.48 P.52 P.48 FT-KV40 FT-KV40W FT-WR80 FT-R41W FT-WR80L FT-R42W FT-WS3 FT-S31W FT-WS4 FT-S21W FT-WS8 FT-S31W FT-WS8L FT-S32 FT-WV42 FT-V25 FT-V24W FT-WZ4 FT-Z20W FT-WZ4HB FT-Z20HBW FT-WZ7 FT-Z40W FT-WZ7HB FT-Z40HBW FT-WZ8 FT-WZ8E FT-WZ8H FT-Z30H FT-R80 FT-R40 P.12 P.51 FT-S32 P.16 P.52 FT-SFM2SV2 FT-V30 P.19 FT-SNFM2 FT-S21 FT-T80 FT-30 FT-40 FT-S20 P.53 FT-S30 P.16 P.52 FT-R31 FT-42 P.12 P.48 FT-R43 FT-V10 FT-V40 P.16 P.53 FT-V22 FT-V23 FT-V41 FT-V25 FT-SFM2 FT-SFM2L FT-W4 FT-W8 FT-WA8 P.19 FT-42 FT-A11W P.53 P.54 P.53 P.54 P.20 P.53 P.54 P.53 P.54 P.48 P.11 P.52 P.15 P.51 Retroreflective type P.12 P.48 FT-A32 FT-A11 P.19 P.52 FT-42W FT-A32W P.52 P.53 FT-31 FT-31W P.16 FT-Z30HW FT-Z8H P.52 P.15 FT-Z30EW FT-Z30E P.16 P.51 FT-Z30H FT-Z8E FT-S11 P.24 FT-Z30W FT-Z30E P.49 FT-PS1 Sensing range Dimensions Specifications FT-Z30 FT-Z30 FT-45X Page FT-S21 FT-Z8 FT-P81X FT-WA30 Amplifiers Sensing range Dimensions Specifications FT-AL05 Fibers Threaded Type Page P.25 P.49 Old fiber New fiber Model No. Model No. FR-KV1 FR-KZ22E FR-KZ21 FR-KZ50H FR-KZ21E FR-KZ50E FR-WKZ11 FR-Z50HW Page Sensing range Dimensions Specifications P.24/P.27 P.55 7 Fiber Selection Guide New product introduction Reflective type Old fiber Model No. FD-A15 FD-AFM2 FD-AFM2E New fiber Model No. FD-AL11 FD-62 FD-E12 FD-E13 FD-E22 FD-E23 FD-EG1 FD-EG30 FD-EG3 FD-EN500S1 FD-ENM1S1 FD-EG31 FD-F71 FD-FA90 FD-FA93 FD-FM2S FD-FM2S4 P.25 P.13 P.17/P.19 FD-61 FD-61G FD-61S FD-G4 FD-42G FD-G6 FD-32G FD-G6X FD-32GX FD-L4 FD-L20H FD-L41 FD-L21 FD-L43 FD-L22A FD-L44 FD-L11 FD-L44S FD-L10 FD-L45 FD-L30A FD-L45A FD-L31A FD-L46 FD-L32H P.19 P.58 P.19 Model FD-SNFM2 FD-S31 P.17 P.64 FD-T40 FD-31 Choose by shape/ application FD-T80 FD-V41 FD-WL41 FD-WL48 FD-WS8 P.13/P.23 P.56 FD-WSG4 FD-WT4 FD-WT8 P.62 P.26 FD-WV42 FD-WZ4 FD-L23 FD-41 P.13 FD-41S P.19 FD-P2 FD-S21 P.17 FD-P40 FD-31 P.13 FD-P50 FD-S32 P.17 FD-P60 FD-41 FD-P80 FD-61 FD-P81X FD-64X FD-R80 FD-R60 FD-S80 FD-S32 P.13 P.56 P.13 P.57 FD-41 P.56 FD-V30 P.64 FD-41S P.19 FD-41SW FD-61 FD-61W FD-42G FD-42GW FD-Z50HW P.56 FD-L21W How to read Model No. Earlier models comparison table Fibers Super Quality P.13 P.57 P.13/P.23 P.24 P.65 P.26 P.62 FD-L21 Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type FD-L12W Small Spot FD-S32 Narrow Beam FD-S32W P.17 P.64 FD-S33GW FD-31W FD-41 P.13 P.56 FD-V30W P.19 P.64 FD-Z20HBW FD-Z40W P.62 FD-WZ7HB FD-Z40HBW FD-30 FD-40 FD-60 P.63 FD-S30 P.56 FD-R31G P.64 FD-R32EG P.56 FD-R33EG P.57 FD-R34EG P.58 FD-R41 Chemical / Oilresistant Vacuumresistant Liquid Leak / Liquid Detection FD-Z20W FD-WZ7 Retroreflective Type Heatresistant FD-41W FD-V30 Wide Beam Convergent Reflective Type FD-31 FD-WZ4HB P.63 P.17 FD-61 P.63 P.56 Fiber Selection Guide P.65 FD-WKZ1 P.57 Sensing range Dimensions Specifications P.19 P.59 P.13 Page FD-V50 FD-W44 P.35 New fiber Model No. FD-SFM2SV2 FD-WG4 FD-NFM2 FD-NFM2S4 P.57 P.13/P.23 FD-L47 FD-NFM2S P.58 Old fiber Model No. FD-W8 FD-EG30S FD-F705 FD-FM2 Sensing range Dimensions Specifications FD-A16 FD-B8 FD-EG2 Page Tough Fiber P.21 P.65 P.56 P.11 P.57 P.64 P.15/P.23 P.15 Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type P.63 Retroreflective Type Reflective Type Others P.64 Amplifiers FX-500 series FX-100 series INDEX 8 New product introduction Tough Fiber Fiber Selection Guide Model Tough Fiber Unbreakable ! More flexible ! ECO ! Conventional 3 types rolled into 1 !! Choose by shape/ application How to read Model No Earlier models comparison table Flexible fiber Flexible durability Fibers Super Quality Threaded Type 1 million times Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Sharp bending fiber Bending radius R2 ~R1 mm Chemical / Oilresistant General purpose fiber Heatresistant Bending radius Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Unbreakable Flexible durability 10 million times (Typical) Bending conditions Bending radius: R10 mm Reciprocating bending: 180 More flexible ~R4 Bending radius R2 mm Wide Beam Convergent Reflective Type Retroreflective Type Tough Fiber R25mm ed gs are us steel fittin ls. e d o m ll Stainless head of a r e b fi e for th s to RoHS tery nform Clearly co d for secondary bat se u th e g b n re an st C mounting Improved Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX New tough fibers exceed normal optic fibers! Tough fibers can be used on moving parts, can be bent with precision, and offer high quality for all purposes. They go beyond what was commonly thought to be possible. 9 Unbreakable ECO Bending conditions Bending radius: R10 mm R0.394 in, Reciprocating bending: 180 Stainless steel fittings are used for the fiber head of all models. Model Choose by shape/ application How to read Model No. Earlier models comparison table Improved tightening torque (Typical) Example: FT-31 Fiber Selection Guide Can be used for secondary batteries 10 million times More flexible Tough Fiber Clearly conforms to RoHS SUS Flexible durability New product introduction Fibers Super Quality R2 to R4 mm R0.079 to R0.157 in Threaded Type Example: FT-42 Square Head Type Cylindrical Type R R2 mm R0.079 in M3 M4 R4 mm R0.157 in Sleeve R Flat Type Small Spot Narrow Beam O2.2 mm O0.087 in O1 mm O0.039 in Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Reduced the time in selecting fiber and in registrating part numbers Heatresistant Vacuumresistant Liquid Leak / Liquid Detection For Designers High-q uality High-quality in whichever tough fiber you choose! Easy selection! Reduces risk of breaking and bending during installation! For Buyers Low P rice Fiber Options Cost savings! Reduced registration of part numbers! Reduced maintenance time in keeping stocks and replacement! Reduced variation in detection Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Beams at the fiber aperture are uniform, leading to stable sensing. Previous flexible fiber Previous sharp Generally flexible fibers and bending fiber sharp bending fibers are composed of multiple fiber cores, often resulting in large variations in light intensity. New fiber The new standard fiber is composed of a single fiber core, achieving uniform light intensity. Uniform and highly accurate sensing Stable sensing even if the fiber is bent Amplifiers FX-500 series FX-100 series INDEX 10 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application Super Quality It is a fiber with superior light intensity stability and simple digital management when combined with the FX-500 series amplifier. It offers stable sensing with an extremely small beam axis curvature and gap. FT-40 How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Digital management is simple due to small differences in body. When connected with the FX-500 series amplifiers, it has up to 4 times improved stability of incident light intensity compared with traditional fibers. Management is simple even when replacing amplifiers because the digital display shows the approximate value. Super quality fiber FX-500 series "Stabilized incident light intensities" even in multiple units Emitter intensity is also stable due to few curvatures and gaps in the beam axis. Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Stable emission amount within 10 % o2.2 mm o0.087 in standard fiber Variation in emission amount of the fiber core is controlled down to less than 10 %, achieving a stable detection. Beam axis deviation: Thru-beam type within 2, Reflective type within 3 Beam axis centering precision: within 150 m Single core standard fiber with high flexibility Previous Retroreflective Type New material Convergent Reflective Type Expanded temperature range Fiber Options Semi-custom fibers Ambient temperature [-40 to +70 C -40 to +158 F in previous model] -55 to +80 C 1.2 -67 to +176 F times more than previous model More flexible! R4 In general, high-flexibility types adopt a multi-fiber core, which may result in large variation in light emission. Bending radius [Previous model is R25 mm R0.984 in] R4 mm R0.157 in 1/6 of that of previous model Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Integrated high-precision plug The centering precision of the fiber core attached to the inserting plug is doubled. As the insertion precision is increased, the variation among units can be greatly suppressed. Centering precision: within 40 m More bendable! Bending durability [Previous model is 1,000 times] 10 million times 10,000 times more than previous model * Bending conditions Bending radius: R10 mm R0.394 in, Reciprocating bending 180 11 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. LIST OF FIBERS Earlier models comparison table Thru-beam type (one pair set) M3 M3 Model No. 7RXJK FT-30 12 M4 M4 Threaded Type Shape of fiber head (mm) 7RXJK FT-40 o1*5 o1.5 10 o3 o3 Cylindrical 15 10 7RXJK FT-S20 7RXJK FT-S30 Bending Fiber radius cable (mm) length R2 Bending durability R4 Bending durability R2 2m Bending durability R4 Bending durability Sensing range (mm in) FX-500 series STD 400 15.748 HYPR 1,350 53.150 STD 1,200 47.244 HYPR (Note) 3,600 141.732 STD 400 15.748 HYPR 1,350 53.150 STD 1,200 47.244 HYPR (Note) 3,600 141.732 U-LG LONG FAST H-SP 810 31.890 650 25.591 210 8.268 75 2.953 2,200 86.614 1,700 66.929 530 20.866 190 7.480 810 31.890 650 25.591 210 8.268 75 2.953 2,200 86.614 1,700 66.929 530 20.866 190 7.480 Beam axis FX-101 Beam position/ Optical Ambient (Upper value) axis dia. Inclination transmission Protection temp. Dimensions (mm) of beam l o ss FX-102 (Lower value) axis 135 5.315 o0.5 400 15.748 P.48 320 12.598 870 34.252 o1 135 5.315 o0.5 400 15.748 150 m 10 % /2 IP67 -55 to +80 C M3 Model No. FD-30 M4 7RXJK FD-40 Bending durability 14 M6 Threaded M4 R2 FD-60 17 o3 2m 7RXJK M6 o3 10 7RXJK FD-S30 R4 Bending durability Cylindrical Type Small Spot Wide Beam Convergent Reflective Type Beam axis position/ Optical Ambient Inclination transmission Protection Dimensions temp. of beam loss (Lower value) axis Sensing range (mm in) (Note) FX-101 U-LG (Upper value) LONG FX-500 series FX-102 FAST H-SP 7RXJK M3 12 Cylindrical Bending Fiber radius cable (mm) length Square Head Type Narrow Beam o1 Reflective type Shape of fiber head (mm) Threaded Type Flat Type Note: The fiber cable length practically limits the sensing range. Type Super Quality Sleeve P.52 320 12.598 870 34.252 Fibers STD 160 6.299 HYPR 600 23.622 330 12.992 250 9.843 80 3.150 25 0.984 STD 900 35.433 740 29.134 140 5.512 260 10.236 420 16.535 90 3.543 HYPR 520 20.472 1,550 61.024 STD 160 6.299 HYPR 600 23.622 330 12.992 250 9.843 80 3.150 25 0.984 45 1.772 155 6.102 P.56 150 m /3 10 % IP67 Note: The sensing range is specified for white non-glossy paper. Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options -55 to +80 C 45 1.772 155 6.102 Retroreflective Type P.57 P.64 Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 12 New product introduction Tough Fiber Threaded Type It is a standard fiber which is mounted using nuts. It has reasonable pricing while drastically improving flexing performance. With the lens installable type, long distance sensing and microscopic object sensing is possible by installing a lens. A protective tube and a sturdy stainless jacket type that prevents disconnection are also prepared. Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Stainless steel fittings are used for the fiber head of all models. Clearly conforms to RoHS Can be used for secondary battery Improved mounting strength Thru-beam type (one pair set) Fiber Options Shape of fiber head (mm) M3 Model No. 7RXJK FT-31 12 M3 Semi-custom fibers M3 FT-31W 12 Lens mountable Fiber Dimensions M4 FT-43 15 Thru-beam Type M4 7RXJK FT-42 R2 Bending durability R1 R4 Bending durability 15 Lens mountable M4 M4 Threaded Lens mountable Fiber Bending cable radius length : (mm) Free-cut FT-42W R1 FT-45X R4 15 Lens mountable, Stainless-jacketed M4 20 M14 FX-100 series Long range Elbow Amplifiers FX-500 series INDEX Improved specularity High precision polishing is accomplished by using the PCTC polishing technique. The specularity of the end face of the fiber is 5 times greater. Light intensity is increased, enabling stable sensing. LIST OF FIBERS Type Others The beam axis deviation of each unit is kept within 3 and the beam axis centering accuracy is kept within 150 m. (Within 5 and 90 m for ultra small diameter fibers) Makes beam axis adjustment easier Improves mounting hole machining accuracy Improves sensing accuracy SUS Supports spot lenses and zoom lenses! Heatresistant Reflective Type Improved centering accuracy It is a coaxial fiber that encloses the circumference of the emitter fiber at the center with the receiver fiber. This is suitable for high-precision positioning. It can perform sensing without affecting the approach direction of the work. Chemical / Oilresistant Retroreflective Type More user-friendly, high quality fiber Coaxial type FD-G in which highprecision positioning can be achieved. Retroreflective Type Liquid Leak / Liquid Detection F T-31/31W/43/42/42W FT-45X/R40 FD-31/41/62/61/R60 * Some models not included (FT-140) Convergent Reflective Type Vacuumresistant FT-42 Lens mountable 7RXJK 15 M4 With expansion lens FT-R40 M14 7RXJK FT-140 40 R4 Bending durability Beam axis FX-101 Beam position/ Ambient (Upper value) axis dia. Inclination Protection temp. Dimensions FX-102 (mm) of beam (Lower value) axis Sensing range (mm in) (Note 1) FX-500 series STD 315 12.402 HYPR 1,350 53.150 STD 260 10.236 HYPR 990 38.976 STD 1,400 55.118 2 m HYPR (Note 2) 3,600 141.732 STD 1,130 44.488 HYPR (Note 2) 3,600 141.732 STD 800 31.496 HYPR 3,300 129.921 STD 1,200 47.244 1m HYPR (Note 2) 1,600 62.992 STD 930 36.614 2 m HYPR (Note 2) 3,600 141.732 STD (Note 2) 19,600 771.654 10 m HYPR (Note 2) 19,600 771.654 U-LG LONG FAST H-SP 770 30.315 150 m -55 to 550 21.654 130 5.118 210 8.268 340 13.386 /2 +80 C 70 2.756 o0.5 590 23.228 150 m -40 to 440 17.323 80 3.150 150 5.906 240 9.449 /3 +60 C 53 2.087 2,800 110.236 2,100 82.677 350 13.780 P.48 770 30.315 970 38.189 o1.5 240 9.449 150 m -55 to /2 +80 C 2,050 80.709 1,600 62.992 300 11.811 530 20.866 800 31.496 190 7.480 IP67 1,900 74.803 150 m -40 to 1,400 55.118 260 10.236 490 19.291 720 28.346 /3 +60 C 160 6.299 o1 1,600 62.992(Note 2) 1,600 62.992(Note 2) 340 13.386 P.49 630 24.803 920 36.220 200 7.874 150 m -55 to /2 +80 C 1,750 68.898 1,500 59.055 270 10.630 P.51 500 19.685 740 29.134 160 6.299 19,600 771.654(Note 2) 551.181 -40 to 19,600 771.654(Note 2) 14,000 19,600 771.654 o10 P.48 16,000 629.921 +70 C (Note 2) 6,300 248.031 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 13 Application FIBER OPTIONS Lens Lens (For thru-beam type fiber) (For reflective type fiber) Detecting a presence of a workpiece FD-32G P.42 New product introduction Tough Fiber P.43 Fiber Selection Guide Model Protective tube P.45 Choose by shape/ application *FTP- *FDP- How to read Model No. Earlier models comparison table LIST OF FIBERS Reflective type Type Shape of fiber head (mm) 12 M3 12 Coaxial, Lens mountable M3 M3 17 Coaxial, Lens mountable, Stainless-jacketed M3 Ultra-small diameter 18 Coaxial, Lens mountable M3 16 Coaxial, Lens mountable M3 16 M4 14 M4 Threaded M4 14 Coaxial, Lens mountable M4 25 Coaxial, Lens mountable M4 25 M6 17 M6 17 M6 17 Coaxial M6 17 Stainless-jacketed M6 Elbow 22 15 M6 Beam axis position/ Ambient Inclination Protection Dimensions temp. of beam (Lower value) axis Sensing range (mm in) (Note 1, 2) FX-101 U-LG (Upper value) LONG FX-500 series FX-102 FAST H-SP 290 11.417 220 8.661 80 3.150 25 0.984 STD 125 4.921 35 1.378 FD-31 Bending 140 5.512 HYPR durability 515 20.276 STD 180 7.087 80 3.150 140 5.512 15 0.591 FD-31W R1 2 m HYPR 45 1.772 60 2.362 12 0.472 330 12.992 STD 380 14.961 7RXJK R2 200 7.874 270 10.630 70 2.756 FD-32G Bending 95 3.740 190 7.480 HYPR 27 1.063 durability 650 25.591 STD 410 16.142 200 7.874 360 14.173 75 2.953 FD-32GX R2 1 m HYPR 100 3.937 210 8.268 (Note 3) 30 1.181 630 24.803 STD 130 5.118 48 1.890 110 4.331 20 0.787 FD-EG30 30 1.181 70 2.756 HYPR 9 0.354 170 6.693 500 mm R4 STD 45 1.772 20 0.787 35 1.378 7 0.276 FD-EG31 12 0.472 25 0.984 HYPR 3.5 0.138 85 3.346 290 11.417 STD 7RXJK R2 125 4.921 220 8.661 35 1.378 FD-41 Bending 80 3.150 140 5.512 HYPR 25 0.984 durability 515 20.276 STD 630 24.803 270 10.630 430 16.929 80 3.150 FD-41W R1 150 5.906 230 9.055 HYPR 45 1.772 900 35.433 STD 380 14.961 7RXJK R2 200 7.874 270 10.630 70 2.756 FD-42G Bending 95 3.740 190 7.480 HYPR 27 1.063 durability 650 25.591 STD 340 13.386 150 5.906 280 11.024 45 1.772 FD-42GW R1 90 3.543 140 5.512 HYPR 25 0.984 670 26.378 2 m STD 1,000 39.370 520 20.472 940 37.008 170 6.693 FD-62 340 13.386 450 17.717 HYPR R4 110 4.331 1,500 59.055 Bending STD 840 33.071 7RXJK durability 450 17.717 670 26.378 120 4.724 FD-61 200 7.874 410 16.142 HYPR 70 2.756 1,400 55.118 STD 630 24.803 270 10.630 430 16.929 80 3.150 FD-61W R1 150 5.906 230 9.055 HYPR 45 1.772 900 35.433 STD 800 31.496 7RXJK R4 420 16.535 650 25.591 120 4.724 FD-61G Bending 200 7.874 350 13.780 HYPR 60 2.362 durability 1,100 43.307 500 19.685 STD 280 11.024 410 16.142 75 2.953 FD-64X R4 1 m HYPR 160 6.299 220 8.661 50 1.969 670 26.378 STD 600 23.622 7RXJK R4 290 11.417 550 21.654 110 4.331 FD-R60 Bending 2 m HYPR 190 7.480 240 9.449 65 2.559 durability 1,100 43.307 7RXJK M3 M6 Model No. Fiber Bending cable radius length : (mm) Free-cut R2 150 m /3 -55 to +80 C Sleeve P.56 Flat Type Small Spot -55 to +80 C Narrow Beam Wide Beam IP40 -40 to +70 C P.58 -20 to +60 C P.59 IP67 -40 to +60 C -55 to +80 C Retroreflective Type Chemical / Oilresistant Vacuumresistant P.56 Convergent Reflective Type Heatresistant -55 to +80 C Liquid Leak / Liquid Detection Fiber Options IP40 -40 to +60 C 150 m /3 -55 to +80 C Semi-custom fibers P.57 IP67 Thru-beam Type Reflective Type -40 to +60 C Fiber Dimensions Retroreflective Type Others IP40 -55 to +80 C 150 m /3 IP67 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. 3) The allowable cutting range is 700 mm 27.559 in from the end that the amplifier inserted. 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. Threaded Type Cylindrical Type -40 to +60 C 150 m /3 Super Quality Square Head Type IP67 Fibers Amplifiers P.58 P.63 FX-500 series FX-100 series INDEX 14 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Square Head Type Compact, space-saving design brings clean installation on the side of a conveyor belt. As for lens compatible type fiber head, sensing range becomes longer when a lens is attached to the thrubeam type fiber, spot detection is achieved in case of the reflective type. A lens equipped type fiber head is also available. Oil resistant type is also available. Please refer to p.28 Compact, space-saving Fiber can be installed at a minimum pitch of M3: 6.5 mm 0.256 in or M4: 8.5 mm 0.335 in using needle-nose pliers. Wrench Cylindrical Type M3 Type Compact installation Square head fiber heads can be installed cleanly on the side of a conveyor belt. The design makes it less likely for tools and other objects to catch on the fiber cable during installation. FT-R / FD-R Standard fiber Needle-nose pliers Sleeve 3.5 mm 0.138 in Flat Type Clean installation! Small Spot M4 Type Tools and other objects can catch on the fiber cable. Space is required. Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant FT-R41W/R42W Introducing square R1 mm (R0.039 in) (sharp bending) fiber We now offer a sharp bending fiber featuring a low level of light fluctuations, even when bent at R1 mm R0.039 in. It is also available with a lens capable of long-range sensing. FT-R41WFT-R42W FT-R42W (With lens) Vacuumresistant Liquid Leak / Liquid Detection R1 mm R0.039 in Lens Fiber head *Resistant to dust and particulate matter. *Tip dimensions can be shortened. Fiber Options Full-protection type Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others High environmental resistance The head, nut, and washer are made from rust-resistant SUS304. The unbreakable tough fiber with high durability is covered in a fluorine resin tube. The fiber head is also covered with a fluorine resin component, achieving a high level of environmental resistance. FT-R60Y (Square head type M6 / thru-beam type) Less susceptibility to oil adhesion thanks to fluorine resin Fibers deliver stable detection, since the sensing part is sealed with fluorine resin, which does not allow oil penetration. Additionally, the detection part features a convex design made of fluorine resin, achieving lower friction than glass. Amplifiers FX-500 series FX-100 series INDEX Resistant to oil and coolant The fiber head and fiber cable are connected by the "fastening and caulking" method without using adhesives. This method eliminates concerns that adhesives will absorb moisture in high-humidity environments and damage the fiber. The enclosure achieves IP68G protection, so the fiber can be installed around metal processing machines shrouded in the oil mist. Test oil Lubricating oil M6 Non-water-soluble cutting oil Fluorine resin (PFA) Stainless steel (SUS304) Water-soluble cutting oil Alcohol-based neutral detergent Less susceptible to oil adhesion than glass Product Velocite Oil No. 3 Yushiron Cut Abas KZ201 Yushiron Cut UH75 Syntilo 9954 (10% diluted) Yushiroken S50N (2% diluted) Super Teepol *Yushiron and Yushiroken are registered trademarks of Yushiro Chemical Industry Co., Ltd. 15 Cable-protection type FT-R44Y / FD-R61Y FT-R44Y (Square head type M4 / thru-beam type) Compatible with optional lens FD-R61Y (Square head type M6 / reflective type) Stainless steel (SUS304) M6 M4 Fluorine resin (PFA) Even stronger than tough fiber The tough fiber has been reinforced by covering it with a fluorine resin tube so that it can be used even in harsh environments where oils and solvents are used. The fiber cable will not harden or break, even if it is splashed with oil. New product introduction Tough Fiber Fiber Selection Guide Protective structure IP67 The head, nut, and washer are made from rust-resistant SUS304. Model Choose by shape/ application LIST OF FIBERS How to read Model No. Thru-beam type (one pair set) Fiber Bending cable radius length : (mm) Free-cut Sensing range (mm in) (Note 1) Beam axis FX-101 dia. Ambient U-LG Dimensions (Upper value) (Fiber Core) Protection temp. LONG FX-500 series FX-102 (mm) FAST (Lower value) H-SP STD 580 22.835 7RXJK R2 M3 270 10.630 100 3.937 440 17.323 o0.5 FT-R31 Bending 160 6.299 340 13.386 HYPR 55 2.165 durability W5.5xH8xD16 1,000 39.370 55 to IP67 Lens mountable +80 C STD 1,600 62.992 7RXJK R4 M4 720 28.346 210 8.268 1,100 43.307 FT-R43 Bending 430 16.929 640 25.197 HYPR 130 5.118 durability 3,000 118.110 W7xH9xD13.5 P.51 o1 STD 1,800 70.866 M4 800 31.496 250 9.843 1,400 55.118 FT-R41W 460 18.110 710 27.953 HYPR W7xH9xD13.9 150 5.906 3,200 125.984 40 to IP40 R1 With expansion lens 2m STD 60 C 3,600 141.732(Note 2) M4 2,200 86.614 3,500 137.795 510 20.079 o2.2 FT-R42W 1,300 51.181 2,000 78.740 HYPR (Note2) 460 18.110 W7xH9xD14.4 3,600 141.732 Cable-protection type STD 1,600 62.992 7RXJK Compatible with lens 720 28.346 210 8.268 1,100 43.307 IP67 o1 FT-R44Y (Note 3) 430 16.929 640 25.197 HYPR R4 130 5.118 W7xH9.5xD15.5 3,000 118.110 55 to P.52 Bending Full-protection type 80 C 3,600 141.732(Note 2) 7RXJK STD durability (Note 2) 690 27.165 2,100 82.677 3,600 141.732 o3.5 IP68G FT-R60Y HYPR 1,260 49.606 1,890 74.409 (Note2) 3,600 141.732 W10xH11xD21.2 400 15.748 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) The fiber part is oil-resistant. Shape of fiber head (mm) Model No. M4 M6 Square head M3 Type Reflective type Type Shape of fiber head (mm) Model No. Fiber Bending cable radius length : (mm) Free-cut R2 Sensing range (mm in) (Note 1, 2) FX-500 series Beam axis FX-101 dia. Ambient U-LG Dimensions (Upper value) (Fiber Core) Protection temp. LONG FX-102 (mm) FAST (Lower value) H-SP 310 12.205 Emitter 55 to 45 1.772 260 10.236 o0.5 85 3.346 150 5.906 80 C 27 1.063 STD 170 6.693 2m HYPR 530 20.866 W5.5xH8xD16 Coaxial, Lens mountable STD 110 4.331 Emitter M3 45 1.772 20 0.787 92 3.622 o0.25 FD-R32EG 30 1.181 68 2.677 HYPR 9 0.354 170 6.693 W5.5xH8xD16 Coaxial, Lens mountable STD 90 3.543 Emitter M3 38 1.496 17 0.669 70 2.756 o0.175 FD-R34EG R4 500m HYPR 23 0.906 60 2.362 7 0.276 130 5.118 W5.5xH8xD16 Coaxial, Lens mountable STD 44 1.732 Emitter M3 19 0.748 7 0.276 33 1.299 o0.125 FD-R33EG 11 0.433 22 0.866 HYPR 3 0.118 84 3.307 W5.5xH8xD16 STD 430 16.929 7RXJK M4 R2 210 8.268 60 2.362 320 12.598 o0.75 FD-R41 Bending 100 3.937 170 6.693 HYPR 34 1.339 710 27.953 durability W7xH9xD13.5 Cable-protection type 2m STD 610 24.016 7RXJK R4 280 11.024 85 3.346 435 17.126 -- FD-R61Y Bending 160 6.299 185 7.283 HYPR 50 1.969 durability 990 38.976 W10xH11xD15.5 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. 3) The fiber part is oil-resistant. 7RXJK FD-R31G Bending durability IP40 M6 M4 Square head M3 Coaxial, Lens mountable M3 40 to 70 C Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers P.63 20 to 60 C IP67 IP67 55 to 80 C (Note 3) Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others FIBER OPTIONS Amplifiers Lens (For square head M3 reflective fiber) P.43 Lens (For thru-beam type fiber) P.42 Earlier models comparison table FX-500 series FX-100 series INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 16 New product introduction Tough Fiber Cylindrical Type Has a slender shape which can be mounted in narrow locations using set screws. Line up that includes ultra-thin fibers with o0.25 mm tips. Fiber Selection Guide Model How to read Model No Earlier models comparison table FD-S31 FT-S32 Choose by shape/ application FT-S21/S21W/S31W FD-S32/S31 User-friendly, high quality fiber Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Improved centering accuracy and specularity Stainless steel fittings are used for the fiber head of all models. Clearly conforms to RoHS Can be used for secondary battery Improved mounting strength Small Spot LIST OF FIBERS Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Thru-beam type (one pair set) Type Shape of fiber head (mm) Chemical / Oilresistant o1 o1 Heatresistant Vacuumresistant 6 Liquid Leak / Liquid Detection o1.5 o1*5 10 o1.5 Fiber Options o2*5 Cylindrical o2.5 8 o3 Retroreflective Type Reflective Type Others Amplifiers o3 o4 Thru-beam Type Side-view Ultra-small diameter 10 Fiber Dimensions 7RXJK FT-S11 7RXJK FT-S21 FT-S21W With lens, Long sensing range o3 Semi-custom fibers 10 Model No. Narrow beam o0.125mm o0.25 o3 Sleeve part cannot be bent. 5 15 Narrow beam o0.25mm Sleeve part cannot be bent. o0.4 o3 5 15 o4 FT-S32 FT-S31W 25 R2 500 mm Bending durability R1 R10 2m Bending durability R1 7RXJK FT-E13 7RXJK FT-E23 7RXJK FT-V40 3 Fiber Bending cable radius length : (mm) Free-cut R2 Bending durability 1m R4 Bending durability 2m Sensing range (mm in) (Note 1) FX-500 series STD 90 3.543 HYPR 350 13.780 STD 315 12.402 HYPR 1,350 53.150 STD 260 10.236 HYPR 990 38.976 STD 3,100 122.047 HYPR (Note 2) 3,600 141.732 STD 800 31.496 HYPR 3,300 129.921 STD 15 0.591 HYPR 52 2.047 STD 75 2.953 HYPR 270 10.630 STD 3,500 137.795 HYPR (Note 2) 3,600 141.732 U-LG LONG FAST H-SP 210 8.268 160 6.299 60 2.362 19 0.748 770 30.315 550 21.654 210 8.268 70 2.756 590 23.228 440 17.323 150 5.906 53 2.087 3,600 141.732(Note 2) 3,600 141.732(Note 2) 1,800 70.866 600 23.622 1,900 74.803 1,400 55.118 490 19.291 160 6.299 30 1.181 24 0.945 8 0.315 2 0.079 160 6.299 125 4.921 42 1.654 13 0.512 3,600 141.732(Note 2) 3,600 141.732(Note 2) 2,400 94.488 850 33.465 FX-101 Beam axis (Upper value) dia. FX-102 (mm) (Lower value) 40 1.575 90 3.543 o0.25 Beam axis position/ Ambient Inclination Protection Dimensions temp. of beam axis 150 m /2 130 5.118 340 13.386 -55 to +80 C IP67 o0.5 150 m /3 80 3.150 240 9.449 1,100 43.307 3,000 118.110 o2 260 10.236 720 28.346 o1 150 m /3 6 0.236 19 0.748 o0.125 22 0.866 o0.25 80 3.150 1,000 39.370 3,100 122.047 o2.5 -40 to P.52 +60 C IP40 -40 to +70 C -40 to +60 C IP67 -40 to P.49 +70 C IP50 -40 to P.53 +60 C Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. FX-500 series FX-100 series INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 17 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Reflective type o1*5 Type Shape of fiber head (mm) Model No. 7RXJK o1.5 FD-S21 10 7RXJK o3 FD-S32 15 o3 Cylindrical o3 FD-S32W 15 7RXJK o3 FD-S31 10 Coaxial o3 FD-S33GW o3 o1*5 Ultra-small diameter 15 o1.5 o0.48 15 3 o0.63 15 5 Sleeve part cannot be bent. FD-E23 Beam axis position/ Ambient Inclination Protection Dimensions temp. of beam (Lower value) axis Sensing range (mm in) (Note 1, 2) FX-101 U-LG (Upper value) LONG FX-500 series FX-102 FAST H-SP 130 5.118 110 4.331 37 1.457 11 0.433 STD 80 3.150 HYPR 190 7.480 STD 420 16.535 HYPR 1,200 47.244 STD 270 10.630 HYPR 900 35.433 790 31.102 660 25.984 120 4.724 220 8.661 345 13.583 75 2.953 630 24.803 430 16.929 150 5.906 45 1.772 80 3.150 230 9.055 STD 125 4.921 HYPR 515 20.276 290 11.417 220 8.661 80 3.150 25 0.984 35 1.378 140 5.512 150 m /3 R1 STD 150 5.906 HYPR 670 26.378 340 13.386 280 11.024 90 3.543 25 0.984 45 1.772 140 5.512 29 1.142 25 0.984 7 0.276 2 0.079 5 0.197 15 0.591 R4 STD 12 0.472 HYPR 50 1.969 STD 55 2.165 HYPR 170 6.693 R2 Bending durability 1m R4 Bending durability R1 R2 2m Bending durability FD-E13 Sleeve part cannot be bent. o3 Fiber Bending cable radius length : (mm) Free-cut 1m 120 4.724 80 3.150 30 1.181 9 0.354 25 0.984 70 2.756 IP40 P.63 IP67 -40 to +60 C -55 to +80 C -40 to +60 C Heatresistant Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type IP40 P.58 20 0.787 70 2.756 Chemical / Oilresistant Liquid Leak / Liquid Detection P.64 Retroreflective Type Vacuumresistant -55 to +80 C 150 m /3 Convergent Reflective Type -40 to +70 C Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 18 New product introduction Tough Fiber Sleeve It is suitable for sensing in narrow locations and sensing minute objects because the fiber tip is a thin sleeve. The 40 mm sleeve type can be bent in any direction. Fiber Selection Guide Model FD-41S Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality FT-42S FT-E13 / FT-E23 Ultra-small diameter fiber Centering accuracy of 1/10 mm or less Ultra-small diameter fibers with a compact head ensure precision centering accuracy* to stably detect minute parts. A B C Threaded Type Square Head Type Dimensions UNCLEAR Cylindrical Type Sleeve Flat Type * Tolerance of A + Tolerance of B + Tolerance of C = 0.09 mm Dimensions unclear Screw Dimensions CLEAR Example: FT-E13 Dimensions unclear o3 mm+0.05 +0.002 o0.118 in 0 Previous general fiber New standard fiber Extra clearance needs to be added when designing and machining the mounting hole due to unclear dimensions. As a result, mounting variation increases and the beam axis deviates, resulting in a decrease in sensing accuracy or causing the sleeve to bend or break. Highly accurate design and machining are possible due to clear mounting hole dimensions. As a result, mounting variation is minimal, improving sensing accuracy. In addition to this, as the beam axis alignment is not affected when the fiber is changed, readjustment is not necessary. o0.5 mm+0.05 +0.002 o0.020 in 0 Screw Dimensions clear Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Minute sensing only possible with ultra small fiber Detection of fine-pitch connector pins Fiber Options FT-E13 Detection of tiny chips Ultra-small diameter fiber with o0.125 mm o0.005 in beam axis is able to detect the insertion or bending of fine-pitch connector pins. Fiber can be installed with only the o0.25 mm o0.010 in sleeve close to the minute section. FT-E13 Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Stainless steel fittings are used for the fiber head of all models. Clearly conforms to RoHS Can be used for secondary battery Improved mounting strength Application FIBER OPTION Fiber bender Amplifiers FX-500 series FX-100 series *FB-1 The fiber bender bends the sleeve part of the fiber head at the proper radius. Note: Do not bend the sleeve part of any side-view type fiber or ultrasmall diameter head type fiber. INDEX 19 LIST OF FIBERS New product introduction Thru-beam type (one pair set) Shape of fiber head (mm) Type 7RXJK M3 FT-31S 10 Sleeve 40mm M4 Narrow beam o0.125mm o0.25 Sleeve part cannot be bent. FT-42S 12 FT-E13 7RXJK o0.4 o3 Sleeve part cannot be bent. FT-E23 5 15 o1 o2 Cylindrical Side-view o2 FT-V23 20 15 o1 o2 FT-V25 15 15 o1 o2 o2*5 R4 Bending durability R2 Bending durability R1 FT-V24W 15 15 o1.5 o2.5 7RXJK 1.3 FT-V30 Sleeve part cannot be bent. 1m 2m 1 Sleeve part cannot be bent. Bending durability 7RXJK 1 Sleeve part cannot be bent. 2m R2 7RXJK 1.1 Sleeve part cannot be bent. R4 Bending durability (Note 3) 7RXJK o3 5 15 Narrow beam o0.25mm R2 Bending durability (Note 3) 7RXJK M4 o1.48 o3 Model No. M3 o0.88 Ultra-small diameter Threaded Sleeve 40mm Sensing range (mm in) (Note 1, 2) Beam FX-101 Ambient U-LG Dimensions axis dia. Protection (Upper value) temp. LONG FX-500 series (mm) FX-102 FAST (Lower value) H-SP Fiber Bending cable radius length : (mm) Free-cut 20 15 R4 Bending durability STD 315 12.402 HYPR 1,220 48.031 STD 1,130 44.488 HYPR (Note 2) 3,600 141.732 STD 15 0.591 HYPR 52 2.047 STD 75 2.953 HYPR 270 10.630 STD 450 17.717 HYPR 1,800 70.866 STD 240 9.449 HYPR 900 35.433 STD 110 4.331 HYPR 380 14.961 STD 680 26.772 HYPR 2,200 86.614 740 29.134 550 21.654 195 7.677 63 2.480 2,050 80.709 1,600 62.992 530 20.866 190 7.480 30 1.181 24 0.945 8 0.315 2 0.079 160 6.299 125 4.921 42 1.654 13 0.512 1,000 39.370 880 34.646 280 11.024 90 3.543 550 21.654 480 18.898 140 5.512 45 1.772 230 9.055 200 7.874 60 2.362 20 0.787 1,200 47.244 1,000 39.370 340 13.386 100 3.937 130 5.118 340 13.386 -55 to +80 C P.48 o1 -40 to +70 C o0.25 160 6.299 400 15.748 o0.75 P.49 P.52 -55 to +80 C 95 3.740 260 10.236 -40 to +60 C 35 1.378 90 3.543 P.53 Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type M3 Ultra-small diameter Shape of fiber head (mm) M3 o0.8 FD-EG30S 15 Sleeve 40 mm 7RXJK M4 Threaded M4 FD-41S o1.48 Sleeve 40 mm M4 FD-41SW o1.48 12 M6 Sleeve 40 mm o1*5 FD-61S o2.5 o1.5 o0.48 R4 1m o3 R1 (Note 3) 2m 1m Sleeve part cannot be bent. o3 Small diameter 15 15 o3 o1.5 7RXJK FD-V30 2 Sleeve part cannot be bent. 15 o3 15 o1.5 FD-V30W 2 R2 Bending durability R1 Sleeve part cannot be bent. o5 15 o5 7RXJK 20 o2 Sleeve part cannot be bent. 2.3 FD-V50 R4 Bending durability STD 50 1.969 HYPR 170 6.693 STD 125 4.921 HYPR 515 20.276 STD 80 3.150 HYPR 330 12.992 HYPR FD-E23 5 Sensing range (mm in) (Note 1, 2) FX-101 U-LG (Upper value) Protection LONG FX-500 series FX-102 STD R4 Bending durability (Note 3) R4 o0.63 15 R2 Bending durability (Note 3) FD-E13 15 3 Sleeve part cannot be bent. o3 Ultra-small diameter Cylindrical 7RXJK M6 15 Side-view Model No. Fiber Bending cable radius length : (mm) Free-cut Sleeve part cannot be bent. 12 Flat Type Small Spot -55 to +80 C o1.0 Square Head Type Sleeve IP30 o0.5 Threaded Type Cylindrical Type Reflective type Sleeve 15 mm Fibers Super Quality Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) Bending radius of sleeve part is R10 mm R0.394 in or more. Type How to read Model No. o0.125 22 0.866 80 3.150 180 7.087 480 18.898 Choose by shape/ application Earlier models comparison table IP67 6 0.236 19 0.748 Fiber Selection Guide Model o0.5 300 11.811 800 31.496 Tough Fiber 2m 420 16.535 1,200 47.244 STD 12 0.472 HYPR 50 1.969 STD 55 2.165 HYPR 170 6.693 STD 65 2.559 HYPR 240 9.449 STD 20 0.787 HYPR 80 3.150 STD 120 4.724 HYPR 370 14.567 FAST (Lower value) H-SP 110 4.331 80 3.150 20 0.787 30 1.181 70 2.756 9 0.354 IP40 Chemical / Oilresistant Ambient temp. Dimensions -40 to +70 C P.59 290 11.417 220 8.661 80 3.150 25 0.984 35 1.378 140 5.512 -55 to +80 C 180 7.087 140 5.512 45 1.772 12 0.472 15 0.591 60 2.362 -40 to +60 C Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options P.56 IP67 790 31.102 660 25.984 130 5.118 220 8.661 360 14.173 75 2.953 -55 to +80 C 29 1.142 25 0.984 7 0.276 2 0.079 5 0.197 15 0.591 120 4.724 80 3.150 30 1.181 9 0.354 20 0.787 70 2.756 -40 to +70 C 130 5.118 120 4.724 35 1.378 14 0.551 25 0.984 75 2.953 -55 to +80 C 40 1.575 30 1.181 10 0.394 2 0.079 6 0.236 20 0.787 -40 to +60 C 220 8.661 210 8.268 75 2.953 25 0.984 40 1.575 100 3.937 Semi-custom fibers P.57 Fiber Dimensions Thru-beam Type -40 to +60 C IP40 P.58 Retroreflective Type Reflective Type Others P.64 IP30 -55 to +80 C Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. 3) Bending radius of sleeve part is R10 mm R0.394 in or more. 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. Amplifiers FX-500 series P.65 FX-100 series INDEX 20 New product introduction Tough Fiber Fiber Selection Guide Model Flat Type Since it has a thin, rectangular shape, it can be installed in narrow locations. It is also a fiber with good workability and can be mounted directly with screws. FT-Z30H FT-Z30E FT-Z30 Choose by shape/ application How to read Model No Earlier models comparison table 1 point mounting The sensor can be mounted on 1 point with either M2 screw or M3 screw. Metal sleeve in the enclosure helps to be tightened firmly even with a single screw. Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Space-saving installation Fiber guide system contributes to space-saving FT-ZHBW and FD-ZHBW is equipped with a fiber guide feature. This enables to mount either way of top sensing and side sensing. M2 screw Top Sensing Side Sensing FD-Z20HBW 10 mm 0.394 in 2 mm 0.079 in Boss Equipped with metal sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant LIST OF FIBERS Thru-beam type (one pair set) Type Vacuumresistant Shape of fiber head (mm) Top sensing W3 x H8 x D12 Model No. 7RXJK FT-Z30H Liquid Leak / Liquid Detection Side sensing W3 x H12 x D8 FX-500 series R1 7RXJK R2 STD (Note 2) STD Bending durability HYPR (Note 2) 2m Side sensing W3 x H12 x D8 FT-Z30EW R1 STD HYPR (Note 2) Front sensing Thru-beam Type W8.5 x H12 x D3 7RXJK FT-Z30 Flat Fiber Dimensions Front sensing Retroreflective Type W8.5 x H12 x D3 Front sensing W10 x H7 x D2 Others Bending durability FX-100 series INDEX With boss FX-500 series HYPR (Note 2) STD FT-Z30W HYPR FT-Z20W 1m Fiber bending type Amplifiers STD R2 (Note 2) Reflective Type W2 x H10 x D10 Front sensing W14 x H7 x D3.5 FT-Z20HBW W3.5 x H14 x D11 R1 FT-Z40W 2m Fiber bending type FT-Z40HBW U-LG LONG FAST H-SP Beam FX-101 Ambient (Upper value) axis dia. Protection temp. Dimensions (mm) FX-102 (Lower value) R2 Bending durability FT-Z30HW FT-Z30E Semi-custom fibers Sensing range (mm in) (Note 1) HYPR Top sensing W3 x H8 x D12 Fiber Options Fiber Bending cable radius length : (mm) Free-cut 3,500 137.795 3,600 141.732 3,500 137.795 3,600 141.732 3,400 133.858 3,600 141.732 2,100 82.677 3,600 141.732 1,500 59.055 3,600 141.732 STD 620 24.409 HYPR (Note 2) 1,600 62.992 STD 260 10.236 HYPR 1,100 43.307 STD 1,500 59.055 HYPR (Note 2) 3,600 141.732 STD 800 31.496 HYPR 3,300 129.921 3,600 141.732(Note 2) 3,600 141.732(Note 2) 1,400 55.118 2,600 102.362 3,200 125.984 810 31.890 2x3 3,600 141.732(Note 2) 3,600 141.732(Note 2) 1,200 47.244 2,400 94.488 3,200 125.984 740 29.134 3,600 141.732(Note 2) 3,600 141.732(Note 2) 1,400 55.118 2,000 78.740 2,600 102.362 630 24.803 3,600 141.732(Note 2) 710 27.953 3,600 141.732(Note 2) 1,200 47.244 2,300 90.551 410 16.142 o2 3,300 129.921 3,200 125.984 540 21.260 1,000 39.370 1,800 70.866 280 11.024 1,500 59.055 1,100 43.307 280 11.024 420 16.535 730 28.740 o1.5 130 5.118 670 26.378 570 22.441 100 3.937 180 7.087 320 12.598 o0.5 55 2.165 3,300 129.921 2,300 90.551 410 16.142 900 35.433 1,200 47.244 o1.5 290 11.417 1,900 74.803 1,400 55.118 260 10.236 o1 490 19.291 720 28.346 160 6.299 P.54 P.53 P.54 IP40 P.53 -40 to +60 C P.54 P.53 IP67 IP40 P.54 IP67 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 21 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Reflective type Type Shape of fiber head (mm) Model No. Bending radius (mm) Fiber cable length : Free-cut Front sensing FD-Z20W W10 x H7 x D2 1m With boss Flat Fiber bending type FD-Z20HBW W2 x H10 x D10 R1 Front sensing FD-Z40W W14 x H7 x D3.5 2m Fiber bending type FD-Z40HBW W3.5 x H14 x D11 Retroreflective Type Sensing range (mm in) (Note 1, 2) FX-101 Ambient U-LG (Upper value) Protection temp. Dimensions LONG FX-500 series FX-102 FAST (Lower value) H-SP 150 5.906 STD 2 to 32 1 to 65 0.039 to 2.559 130 5.118 0.079 to 1.260 IP40 2 to 45 0.079 to 1.772 1 to 80 HYPR 5 to 13 0.197 to 0.512 0.039 to 3.150 260 10.236 1 to 210 0.039 to 8.268 STD 2 to 30 2 to 85 0.079 to 3.346 1 to 180 0.039 to 7.087 0.079 to 1.181 2 to 55 0.079 to 2.165 1 to 90 IP67 HYPR 3 to 15 0.118 to 0.591 0.039 to 3.543 1 to 340 0.039 to 13.386 -40 to P.65 +60 C 440 17.323 STD 1 to 74 190 7.480 390 15.354 0.039 to 2.913 1 to 120 0.039 to 4.724 200 IP40 HYPR 2 to 35 0.079 to 1.378 790 31.102 7.874 540 21.260 STD 1 to 90 260 10.236 470 18.504 0.039 to 3.543 1 to 160 0.039 to 6.299 0.5 to 240 IP67 HYPR 2 to 50 0.079 to 1.969 0.020 to 9.449 760 29.921 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 22 New product introduction Tough Fiber Fiber Selection Guide Model Small Spot Sensing of minute objects can be performed by combining the fiber and spot lens. The spot diameter can also be changed. Choose by shape/ application How to read Model No Earlier models comparison table Applications Packing detection Number of IC pins checking FD-42G/42GW FD-EG31 Fibers Super Quality Discrimination of 0603 chip direction FX-MR6 (lens) + FD-EG31 (fiber) IC FX-MR5 FX-MR3 Threaded Type Square Head Type Cylindrical Type Because it's a side-view type, it can be mounted even in narrow spaces. Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Three optional lenses for reflective type fiber are available. Perfect for chip component detection applications. Finest spot lens FX-MR7 Parallel light lens FX-MR9 About 3 times more light received (compared to previous models) Long-range parallel light Since there is a large difference in the amount of light received in applications such as direction detection, it is easy to set a threshold that will allow stable detection. Additionally, these products offer an S/N ratio that is 1.3 times better than previous models. Depending on the fiber with which it is used, this lens creates parallel light with a spot diameter of approximately o4 mm o0.157 in at a sensing range of 0 to 30 mm 0 to 1.181 in. Typical FX-501 erformance (STD mode) Fiber Options Semi-custom fibers FX-MR7 / MR8 / MR9 White Black FX-MR7 + FD-R33EG 3,200 digits 1,030 digits FX-MR6 (compared to previous models) + FD-R33EG 1,000 digits 435 digits Zoom lens FX-MR8 All models Tightening torque 5 times (compared to previous models) The standard aluminum body has been changed to stainless steel (SUS 303) to reduce the likelihood of damage from over-tightening. Fiber Dimensions Variable spot diameter Standard lens outer diameter of o4.3 mm (o0.169 in) Thru-beam Type Spot diameters ranging from o0.4 to o3.5 mm o0.016 to o0.138 in can be achieved by combining the lens with a variety of fibers. Use of the same mounting hardware across the product line means less inventory and lower costs. Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 23 LIST OF FIBERS New product introduction High precision fiber & spot lens Shape of head (mm) Dimensions Designation Spot diameter (mm in) (Note) 16 P.68 o4 P.68 Lens Distance to focal point Ambient (mm in) (Note) Model No. temp. Applicable fibers Fiber cable Bending Ambient Model No. length radius Protection Dimensions temp. : Free-cut (mm) o0.1 o0.004 FD-EG31 o0.2 o0.008 FD-EG30 500 mm 7RXJK 70.5 0.2760.020 FX-MR6 -20 to +60 C o0.4 o0.016 P.68 o4 P.68 FD-42GW o0.15 o0.006 FD-EG31 o0.3 o0.012 FD-EG30 Bending durability 1m 500 mm 7RXJK FX-MR3 o0.5 o0.020 7RXJK 20.2 Pinpoint spot lens o4 o0.5 o0.020 Zoom lens (Side-view type) o7.1 P.67 W6.3 x H20.3 x D10.3 FX-MR1 -40 to +70 C P.68 o0.7 to o2.0 o0.028 to o0.079 Approx.18.5 to 43 Approx. 0.728 to 1.693 o0.5 to o3.0 o0.020 to o0.118 Approx.13 to 30 Approx. 0.512 to 1.181 1m 7RXJK Bending durability FD-42GW 7RXJK FX-MR2 -40 to +70 C FD-42G 2m FD-42GW -40 to +70 C -40 to +60 C P.57 FD-42G R2 -55 to +80 C R1 -40 to +60 C R2 -55 to +80 C R1 FD-42GW Type Spot diameter (mm in) (Note) Lens Shape (mm in) Model No. Dimensions Shape o0.1 o0.004 approx. o0.15 o0.006 approx. Finest spot lens o0.2 o0.008 approx. 7 0.5 0.276 0.020 o5 o0.197 15.3 0.602 FX-MR7 o0.4 o0.016 approx. Type Spot diameter (mm in) (Note) P.68 Lens Sensing range (mm in) (Note) Shape (mm in) o0.4 to o2.0 o0.016 to o0.079 approx. Zoom lens o0.4 to o2.2 o0.016 to o0.087 approx. 10 to 30 o5 o0.197 o0.5 to o2.5 o0.020 to o0.098 approx. 0.394 to1.181 o0.8 to o3.5 o0.031 to o0.138 approx. Parallel light lens o4.0 o0.157 approx. Model No. 15 0.591 FX-MR8 P.68 10 0.394 0 to 30 0 to 1.181 FX-MR9 o5 o0.197 P.68 Emitting fiber core (mm in) Fiber Emitting fiber core (mm in) Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Flat Type Narrow Beam Wide Beam P.57 -40 to +60 C Square head type M3, Reflective type fiber & spot lens Distance to focal point (mm in) (Note) How to read Model No. Small Spot -55 to +80 C -40 to +60 C Bending durability Choose by shape/ application Sleeve -55 to P.56 +80 C R1 Bending durability 7RXJK FX-MR5 R2 R2 FD-42G P.67 27.1 Zoom lens 61 0.2360.039 IP40 -55 to +80 C R2 Bending durability FD-32GX P.68 R4 R1 2m Model Earlier models comparison table -20 to P.59 +60 C -40 to P.58 +70 C R2 FD-42GW Fiber Selection Guide -55 to P.56 +80 C R2 Bending durability FD-42G FD-32G P.57 R2 FD-32GX -40 to +70 C -40 to +60 C R1 2m 7RXJK 7.50.5 0.2950.020 -55 to +80 C Bending durability FD-42G P.68 15 R4 R2 FD-32G Finest spot lens -20 to P.59 +60 C -40 to P.58 +70 C Tough Fiber Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Model No. o0.125 o0.005 FD-R33EG o0.125 o0.005 FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG o0.25 o0.010 FD-EG30 o0.5 o0.020 FD-R31G o0.5 o0.020 FD-32G o0.5 o0.020 FD-32GX o0.5 o0.020 FD-42G o0.5 o0.020 FD-42GW Applicable fibers Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Model No. o0.125 o0.005 FD-R33EG, FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG, FD-EG30 o0.5 o0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW o0.125 o0.005 FD-R33EG, FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG, FD-EG30 o0.5 o0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW Note: Spot diameter, distance to focal point and sensing range are specified for FX-500/FX-100 series. 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. Amplifiers FX-500 series FX-100 series INDEX 24 New product introduction Tough Fiber Narrow Beam Since the beam is narrow, it has a feature by which it is not easily affected by surrounding obstacles even in long distances. Fiber Selection Guide Model Choose by shape/ application Applications How to read Model No Detection of a transparent tube Aperture angle 3 Mapping of a wafer Earlier models comparison table FR-KZ50H Fibers Super Quality Threaded Type Square Head Type Cylindrical Type LIST OF FIBERS Thru-beam type (one pair set) Type Sleeve Shape of fiber head (mm) Aperture angle 2 o3.5 o3.7 Flat Type Wide Beam Convergent Reflective Type Narrow beam Narrow Beam Aperture angle 2 o4 3 Retroreflective Type Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others With Ultra-narrow polarizing beam filter Narrow beam Semi-custom fibers Type Side sensing Top sensing Fiber Options INDEX Long range Amplifiers FX-100 series 7RXJK FT-KV40 STD Bending durability STD 2m R1 STD 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 HYPR (Note 2) 7RXJK FT-KV26 20 STD R2 3,600 141.732 (Note 2) HYPR 25 Aperture angle 3 1.5 x 2 (Note 2) HYPR R2 25 FT-KV40W FX-500 series 3,600 141.732 710 27.953 HYPR 2,500 98.425 Bending durability Beam FX-101 axis (Upper value) dia. FX-102 (mm) (Lower value) U-LG LONG FAST H-SP 3,600 141.732(Note 2) 2,200 86.614 3,600 141.732(Note 2) 3,600 141.732 o2.2 3,600 141.732(Note 2) (Note 2) 1,200 47.244 3,600 141.732(Note 2) 3,600 141.732(Note 2) 3,600 141.732(Note 2) 1,200 47.244 2,200 86.614 3,600 141.732 o2.5 3,600 141.732(Note 2) (Note 2) (Note 2) 3,600 141.732 3,100 122.047 940 37.008 1,600 62.992 1,200 47.244 135 5.315 440 17.323 560 22.047 o1 160 6.299 Beam axis position/ Ambient Inclination Protection Dimensions temp. of beam axis IP40 -40 to P.51 +60 C 0.8 IP30 X1 Z0.5 Shape of fiber head (mm) Model No. W5.2 x H9.5 x D16 FR-Z50HW Fiber Bending cable radius length : (mm) Free-cut R1 W30 x H30 x D0.5 Sensing range (mm in) (Note 1, 3) U-LG LONG FAST H-SP STD 100 to 1,400 3.937 to 55.118 100 to 990 3.937 to 38.976 100 to 1,200 3.937 to 47.244 100 to 780 3.937 to 30.709 HYPR 100 to 1,900 3.937 to 74.803 100 to 490 3.937 to 19.291 FX-500 series FX-101 Ambient (Upper value) Protection temp. Dimensions FX-102 (Lower value) 100 to 550 -25 to 3.937 to 21.654 100 to 830 IP40 +55 C 3.937 to 32.677 W7.5 x H2.2 x D11.2 Aperture angle 3 (emitter) 7RXJK FR-KZ50H W10.6 x H28 x D10.1 W9.5 x H25 x D5.2 15 to 310 0.591 to 12.205 HYPR 15 to 570 0.591 to 22.441 FR-KZ22E W4 x H2 x D21.5 W5.2 x H9.5 x D21 STD 7RXJK R2 15 to 460 0.591 to 18.110 15 to 410 0.591 to 16.142 15 to 220 0.591 to 8.661 15 to 100 0.591 to 3.937 15 to 200 0.591 to 7.874 15 to 360 0.591 to 14.173 2m Bending durability STD 20 to 300 0.787 to 11.811 HYPR 20 to 1,000 0.787 to 39.370 7RXJK FR-KZ50E P.55 -40 to IP30 +60 C 20 to 800 0.787 to 31.496 20 to 400 0.787 to 15.748 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 350 0.787 to 13.780 W28 x H10.6 x D10.1 Reflective type Type FX-500 series FT-KS40 Sensing range (mm in) (Note 1) Retroreflective type Vacuumresistant Liquid Leak / Liquid Detection 3 Fiber Bending cable radius length : (mm) Free-cut 7RXJK Aperture angle 2 o4 2 Chemical / Oilresistant Heatresistant Model No. 20 Side-view Small Spot FT-KV40 Shape of fiber head (mm) Model No. Fiber Bending cable radius length : (mm) Free-cut Sensing range (mm in) (Note1) FX-500 series STD W5.2 x H9.5 x D16 FD-Z50HW R1 2m HYPR 10 to 650 0.394 to 25.591 10 to 2,500 0.394 to 98.425 U-LG LONG FAST H-SP 10 to 1,100 0.394 to 43.307 10 to 1,000 0.394 to 39.370 10 to 410 0.394 to 16.142 15 to 130 0.591 to 5.118 FX-101 Ambient (Upper value) Protection temp. Dimensions FX-102 (Lower value) 10 to 200 -40 to 0.394 to 7.874 10 to 530 IP40 +60 C P.65 0.394 to 20.866 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. Refer to P.27 or 38 for the sensing range when FR-Z50HW is used in combination with a reflector (optional). 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 25 Wide Beam New product introduction Tough Fiber Senses a workpiece with indefinite shape or position in the wide beam without missing. It can also be used to discriminate shape. Fiber Selection Guide FT-A11 Model Choose by shape/ application How to read Model No. Applications Sensing tiny moving objects Inspecting screw height Control the amount of meandering Confirming presence of slit mask FD-A16 Spot size 2 x 15mm (by a distance of 15mm) FT-A11 FT-A32 Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Type : With slit mask Type : Without slit mask Small Spot Thru-beam type (one pair set) Type Sensing width 32mm Model No. 7RXJK FT-A32 W5 x H69 x D20 Fiber Bending cable radius length : (mm) Free-cut R2 Bending durability Wide beam W4.2 x H31 x D13.5 Allows flexible wiring Sensing width 11mm R1 Array W5 x H15 x D15 (Note 2) HYPR (Note 2) 7RXJK FT-A11 FT-A11W R2 2m Bending durability R1 W4.2 x H31 x D13.5 Sensing width 5.5mm (Note 2) (Note 2) STD FT-A32W 7RXJK FT-AL05 R2 Bending durability U-LG LONG FAST H-SP FX-500 series HYPR W5 x H69 x D20 Sensing width 11mm Sensing range (mm in) (Note 1) STD Allows flexible wiring Sensing width 32mm STD 3,600 141.732 3,600 141.732 3,600 141.732 3,600 141.732 3,600 3,600 3,600 3,600 141.732 Beam axis dia. (mm) Protection Ambient Dimensions temp. Chemical / Oilresistant -40 to +60 C 2,100 82.677 3,600 141.732 Heatresistant (Note 2) 3,600 141.732(Note 2) 3,600 141.732(Note 2) 3,600 141.732(Note 2) 3,000 118.110 3,600 141.732 3.2 x 32 (Note 2) Vacuumresistant -40 to +55 C IP40 1,900 74.803 3,600 141.732 Liquid Leak / Liquid Detection P.49 -40 to +70 C (Note 2) Fiber Options 2.2 x 11 1,700 66.929 3,400 133.858 250 9.843 660 25.984 0.25 x 5.5 -40 to +55 C Semi-custom fibers -55 to +80 C Fiber Dimensions Thru-beam Type Reflective type Array Wide beam Type Model No. 7RXJK FD-A16 W7 x H15 x D30 7RXJK FD-AL11 W5 x H20 x D20 Fiber Bending cable radius length : (mm) Free-cut R4 Bending durability R2 Bending durability 2m Retroreflective Type Sensing range (mm in) (Note 1, 2) FX-101 FX-500 series STD 200 7.874 HYPR Cannot use STD 320 12.598 HYPR 670 26.378 Wide Beam Convergent Reflective Type Retroreflective Type 141.732(Note 2) 141.732(Note 2) 141.732(Note 2) 3,600 141.732(Note 2) 3,600 141.732(Note 2) 3,600 141.732(Note 2) HYPR (Note 2) 3,600 141.732 1,100 43.307 STD 3,600 141.732(Note 2) (Note 2) 3,600 141.732 3,600 141.732(Note 2) 3,600 141.732(Note 2) HYPR (Note 2) 3,600 141.732 1,300 51.181 STD 1,550 61.024 860 33.858 1,500 59.055 500 19.685 HYPR 170 6.693 2,300 90.551 (Note 2) FX-101 (Upper value) FX-102 (Lower value) Narrow Beam Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. Shape of fiber head (mm) Sleeve Flat Type LIST OF FIBERS Shape of fiber head (mm) Cylindrical Type Ambient U-LG (Upper value) Protection temp. LONG FX-102 FAST (Lower value) H-SP 200 7.874 -40 to 200 7.874 120 4.724 140 5.512 240 9.449 +60 C 75 2.953 IP40 530 20.866 -55 to 510 20.079 100 3.937 180 7.087 285 11.220 +80 C 50 1.969 Dimensions P.58 Reflective Type Others Amplifiers FX-500 series FX-100 series Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 26 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Convergent Reflective Type It is a fiber in which the sensing distance is limited to a specific range so it is not easily affected by the background. It is effective when a workpiece is accumulated or when the background is near. Applications Detecting a passing glass LCD transportation Mounting in handling arms Mapping fiber FD-L32H Seating Fibers Super Quality confirmation fiber FD-L11 FD-L30A Threaded Type FD-L12W Square Head Type Cylindrical Type Alignment fiber FD-L22A/L30A/L31A Sleeve Flat Type Small Spot LIST OF FIBERS Reflective type Narrow Beam Wide Beam Type Convergent Reflective Type Shape of fiber head (mm) Model No. Mapping Retroreflective Type FD-L32H Chemical / Oilresistant W25 x H7.3 x D30 7RXJK Alignment Heatresistant FD-L30A Vacuumresistant W20 x H29 x D3.8 Alignment Liquid Leak / Liquid Detection 7RXJK FD-L31A Fiber Options Semi-custom fibers Glass substrate detection W23.5 x H29 x D4.5 Fiber Dimensions Alignment FD-L22A W17 x H29 x D3.8 Seating confirmation 7RXJK FD-L23 W12 x H19 x D3 7RXJK FD-L10 7RXJK FD-L21 Reflective Type W24 x H21 x D4 Others FD-L21W FX-500 series FX-100 series INDEX Ultlasmall Amplifiers General purpose W24 x H21 x D4 7RXJK 0 to 43 0 to 1.693 0 to 40 0 to 1.575 0 to 50 0 to 1.969 Bending durability 4 to 33 0.157 to 1.299 HYPR 3 to 35 0.118 to 1.378 4 to 33 0.157 to 1.299 4 to 33 0.157 to 1.299 4 to 32 0.157 to 1.260 5 to 25 0.197 to 0.984 5 to 30 0.197 to 1.181 4 to 33 0.157 to 1.299 R2 STD 0 to 24 0 to 0.945 HYPR 0 to 31 0 to 1.220 0 to 28 0 to 1.102 0 to 27 0 to 1.063 0 to 24 0 to 0.945 0 to 18 0 to 0.709 0 to 19 0 to 0.748 0 to 25 0 to 0.984 0 to 30 0 to 1.181 0 to 30 0 to 1.181 0 to 28 0 to 1.102 1.5 to 24 0.059 to 0.945 0 to 28 0 to 1.102 0 to 30 0 to 1.181 0 to 10.5 0 to 0.413 0 to 10 0 to 0.394 0 to 9 0 to 0.354 0 to 8 0 to 0.315 0 to 8 0 to 0.315 0 to 9 0 to 0.354 0 to 5.5 0 to 0.217 0 to 5.5 0 to 0.217 0 to 4.5 0 to 0.177 0 to 4 0 to 0.157 0 to 4.5 0 to 0.177 0 to 5.5 0 to 0.217 STD 1.5 to 16 0.059 to 0.630 HYPR 1 to 19 0.039 to 0.748 1 to 18 0.039 to 0.709 1 to 18 0.039 to 0.709 2 to 15 0.079 to 0.591 3 to 12 0.118 to 0.472 3 to 15 0.118 to 0.591 1.5 to 16 0.059 to 0.630 STD 3 to 14 0.118 to 0.551 HYPR 1.5 to 15 0.059 to 0.591 STD 23 0.906 HYPR 45 1.772 STD 8 0.315 HYPR 14 0.551 2 to 15 0.079 to 0.591 2 to 15 0.079 to 0.591 4 to 14 0.157 to 0.551 6.5 to 10 0.256 to 0.394 7 to 12 0.276 to 0.472 3 to 14 0.118 to 0.551 35 1.378 32 1.260 2 to 15 0.079 to 0.591 5 to 9 0.197 to 0.354 5 to 15 0.197 to 0.591 1 to 30 0.039 to 1.181 12.5 0.492 12 0.472 0.5 to 7 0.020 to 0.276 0.5 to 4 0.020 to 0.157 1 to 4.5 -40 to 0.039 to 0.177 0.5 to 7 IP30 +60 C 0.020 to 0.276 4m R2 R4 HYPR 3m 2m Bending durability R4 W7.2 x H7.5 x D2 R2 2m R1 R2 FD-L12W R1 0 to 110 0 to 4.331 0 to 43 0 to 1.693 STD 0 to 29 0 to 1.142 HYPR 0 to 30 0 to 1.181 STD 0 to 9.5 0 to 0.374 HYPR 0 to 11.5 0 to 0.453 STD 0 to 5 0 to 0.197 HYPR 0 to 6 0 to 0.236 Bending durability Bending durability 0 to 56 0 to 2.205 STD 3m Bending durability HYPR STD Bending durability FD-L20H W6 x H18 x D14 FX-101 Ambient (Upper value) Protection temp. Dimensions FX-102 (Lower value) 0 to 43 0 to 1.693 0 to 43 0 to 1.693 0 to 42 0 to 1.654 0 to 29 0 to 1.142 Bending durability W12 x H19 x D3 Retroreflective Type U-LG LONG FAST H-SP 16 to 30 0.630 to 1.181 0 to 50 0 to 1.969 7RXJK FD-L11 FX-500 series 0 to 87 0 to 3.425 0 to 74 0 to 2.913 1 to 38 0.039 to 1.496 Cannot use W18 x H29 x D3.8 Seating confirmation Sensing range (mm in) (Note 1, 2) STD R4 7RXJK Seating confirmation Thru-beam Type Fiber Bending cable radius length : (mm) Free-cut 1m -40 to P.63 +60 C 0 to +70 C -20 to +70 C IP40 P.62 -40 to +60 C -40 to +70 C Notes: 1) The sensing range is specified for transparent glass 100 x 100 x t0.7 mm 3.937 x 3.937 x t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm t0.079 in) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm 3.937 x 3.937 in). 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 27 Retroreflective Type New product introduction Tough Fiber Compared with the thru-beam type, it is easier to arrange the fibers since one side is a reflector. Sensing transparent objects is also its advantage. Fiber Selection Guide Model Choose by shape/ application Applications Detecting transparent film How to read Model No. Detecting transparent seals on transparent sheet Earlier models comparison table FR-KZ50E FR-Z50HW Fibers Super Quality Threaded Type Reflector RF-003 (Accessory for FR-KZ50E) Square Head Type Cylindrical Type Sleeve LIST OF FIBERS Flat Type Retroreflective type Narrow beam With Ultra-narrow polarizing beam Side sensing Top sensing filters Type Shape of fiber head (mm) Model No. Fiber Bending cable radius length : (mm) Free-cut W5.2 x H9.5 x D16 R1 FR-Z50HW W30 x H30 x D0.5 Small Spot Sensing range (mm in) (Note 1, 2) U-LG LONG FX-500 series FAST H-SP STD 100 to 1,400 3.937 to 55.118 100 to 990 3.937 to 38.976 100 to 1,200 3.937 to 47.244 100 to 780 3.937 to 30.709 HYPR 100 to 1,900 3.937 to 74.803 100 to 490 3.937 to 19.291 FX-101 (Upper value) FX-102 (Lower value) Protection Ambient Dimensions temp. STD 15 to 310 0.591 to 12.205 HYPR 15 to 570 0.591 to 22.441 FR-KZ22E W4 x H2 x D21.5 W5.2 x H9.5 x D21 100 to 550 3.937 to 21.654 IP40 -25 to 100 to 830 +55 C 3.937 to 32.677 FR-KZ50H W10.6 x H28 x D10.1 W9.5 x H25 x D5.2 Bending durability Retroreflective Type Chemical / Oilresistant FR-KZ50E Heatresistant P.55 IP30 STD 20 to 300 0.787 to 11.811 HYPR 20 to 1,000 0.787 to 39.370 7RXJK 15 to 200 0.591 to 7.874 15 to 360 0.591 to 14.173 2m R2 7RXJK 15 to 460 0.591 to 18.110 15 to 410 0.591 to 16.142 15 to 220 0.591 to 8.661 15 to 100 0.591 to 3.937 20 to 800 0.787 to 31.496 20 to 400 0.787 to 15.748 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 -40 to +60 C 20 to 200 0.787 to 7.874 20 to 350 0.787 to 13.780 RF-220 RF-210 Liquid Leak / Liquid Detection W28 x H10.6 x D10.1 Sensing range when FR-Z50HW is used in combination with a reflector (optional) RF-230 Vacuumresistant Fiber Options Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. Reflector model No. Wide Beam Convergent Reflective Type W7.5 x H2.2 x D11.2 7RXJK Narrow Beam HYPR U-LG 100 to 19,000 3.937 to 748.030 100 to 8,000 3.937 to 314.960 100 to 5,500 3.937 to 216.535 100 to 8,000 3.937 to 314.960 100 to 4,700 3.937 to 185.039 100 to 2,700 3.937 to 106.299 Sensing range (mm in) FX-500 series LONG STD FAST 100 to 5,000 3.937 to 196.850 100 to 3,500 3.937 to 137.795 100 to 2,400 3.937 to 94.488 100 to 3,600 3.937 to 141.732 100 to 3,000 3.937 to 118.110 100 to 1,500 3.937 to 59.055 100 to 2,900 3.937 to 114.173 100 to 1,800 3.937 to 70.866 100 to 1,200 3.937 to 47.244 H-SP 100 to 1,400 3.937 to 55.118 100 to 830 3.937 to 32.677 100 to 530 3.937 to 20.866 FX-101 100 to 2,400 3.937 to 94.488 100 to 1,300 3.937 to 51.181 100 to 980 3.937 to 38.583 FX-102 100 to 5,000 3.937 to 196.850 100 to 2,600 3.937 to 102.362 100 to 1,300 3.937 to 51.181 Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Note: The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than 100 mm 3.937 in. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. Amplifiers FIBER OPTION Reflectors (for FR-Z50HW) P.45 FX-500 series FX-100 series INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 28 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Chemical / Oil-resistant With the case and fiber sheath made of PFA, the fiber can be used with various types of chemical liquids. The fiber core will not harden or break, even in environments where oil is present. Full-protection type FT-R60Y (Square head type M6 / thru-beam type) High environmental resistance The head, nut, and washer are made from rust-resistant SUS304. The unbreakable tough fiber with high durability is covered in a fluorine resin tube. The fiber head is also covered with a fluorine resin component, achieving a high level of environmental resistance. Less susceptibility to oil adhesion thanks to fluorine resin Fibers deliver stable detection, since the sensing part is sealed with fluorine resin, which does not allow oil penetration. Additionally, the detection part features a convex design made of fluorine resin, achieving lower friction than glass. Sleeve Flat Type M6 Test oil Lubricating oil Small Spot Non-water-soluble cutting oil Narrow Beam Wide Beam Convergent Reflective Type Resistant to oil and coolant The fiber head and fiber cable are connected by the "fastening and caulking" method without using adhesives. This method eliminates concerns that adhesives will absorb moisture in high-humidity environments and damage the fiber. The enclosure achieves IP68G protection, so the fiber can be installed around metal processing machines shrouded in the oil mist. Stainless steel (SUS304) Fluorine resin (PFA) Water-soluble cutting oil Less susceptible to oil adhesion than glass Retroreflective Type Alcohol-based neutral detergent Product Velocite Oil No. 3 Yushiron Cut Abas KZ201 Yushiron Cut UH75 Syntilo 9954 (10% diluted) Yushiroken S50N (2% diluted) Super Teepol *Yushiron and Yushiroken are registered trademarks of Yushiro Chemical Industry Co., Ltd. Chemical / Oilresistant Heatresistant Cable-protection type Vacuumresistant FT-R44Y (Square head type M4 / thru-beam type) Liquid Leak / Liquid Detection Compatible with optional lens Stainless steel (SUS304) Fiber Options M4 Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX FT-R44Y / FD-R61Y Fluorine resin (PFA) Full-protection type Metal-free design Since no metal components are used, there is no need to worry about metal contamination, even if the protective tube is damaged. It is ideal for use in applications such as semiconductor front-end equipment where a clean environment is required. FD-R61Y (Square head type M6 / reflective type) Stainless steel (SUS304) M6 Fluorine resin (PFA) FD-S60Y (Cylindrical type / reflective type) Metal-free Detection in long range and narrow view A built-in lens achieves narrow-view detection with an aperture angle of 30 degrees. Improved tip flexibility The protective tube features a bending radius of R30mm R1.181in, which improved the cable arrangement compared to previous (R40mm R1.575in) designs. R30 mm R1.181 in Metal-free design o4 mm o0.157 in o5.5 mm o0.217 in 29 LIST OF FIBERS New product introduction Thru-beam type (one pair set) Shape of fiber head (mm) Model No. FT-R44Y W7xH9.5xD15.5 Full-protection type 7RXJK FT-R60Y R4 Bending durability 2m W10xH11xD21.2 Easy mounting * Rectangular head SEMI S2 compliant W7 x H15 x D13 Metal-free Sensing range (mm in) (Note 1) FX-500 series STD 7RXJK Cable-protection type Compatible with lens 720 28.346 HYPR 3,000 118.110 STD 2,100 82.677 HYPR (Note 2) 3,600 141.732 FT-Z802Y STD R4 Bending durability 2m HYPR (Note 2) STD o5.5 FT-HL80Y (Note 2) HYPR (Note 2) (25) Metal-free STD o5.5 FT-L80Y R30 (25) (Note 2) 2m HYPR (Note 3) (Note 2) Side-view STD Metal-free o5.5 (25) U-LG LONG FAST H-SP 1,600 62.992 1,100 43.307 430 16.929 130 5.118 3,600 141.732(Note 2) 3,600 141.732(Note 2) 1,260 49.606 400 15.748 Beam FX-101 axis Ambient (Upper value) dia. Protection temp. Dimensions FX-102 (mm) (Lower value) 210 8.268 640 25.197 o1 IP67 (Note 4) P.52 FT-V80Y HYPR 3,600 141.732(Note 2) 3,100 122.047 3,600 141.732(Note 2) 520 20.472 1,900 74.803 3,100 122.047 470 18.504 3,600 141.732 3,600 141.732(Note 2) 3,600 141.732 3,600 141.732(Note 2) 2,300 90.551 740 29.134 3,600 141.732 3,600 141.732 Choose by shape/ application Earlier models comparison table P.54 Fibers Super Quality 990 38.976 o3.7 IP68G -40 to P.50 2,340 92.126 +115 C 3,600 141.732(Note 2) 3,600 141.732 3,600 141.732(Note 2) 1,100 43.307 2,800 110.236 2,600 102.362 920 36.220 3,600 141.732 1,300 51.181 (Note 2) 0 to +60 C Fiber Selection Guide How to read Model No. -55 to +80 C 690 27.165 1,890 74.409 o3.5 Tough Fiber Model -55 to +80 C 7RXJK Heat-resistant 115 C Metal-free Cylindrical type Chemical-resistant Flat type Oil-resistant Square head type M6 M4 Type Fiber Bending cable radius length : (mm) Free-cut 2,800 110.236 2,200 86.614 800 31.496 240 9.449 P.51 -40 to +70 C 340 13.386 800 31.496 o2.8 Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type P.53 Small Spot Narrow Beam Notes:1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted. 4) The fiber part is oil-resistant. Convergent Reflective Type Reflective type Retroreflective Type Chemical-resistant Oil-resistant Square head type Cylindrical type M6 Type Shape of fiber head (mm) Cable-protection type W10xH11xD15.5 Metal-free Model No. 7RXJK FD-R61Y 16 R4 Bending durability Protective tube R30 mm Fiber 7RXJK o5.5 Fiber Bending cable radius length : (mm) Free-cut FD-S60Y 2m Sensing range (mm in) (Note 1, 2) FX-101 U-LG (Upper value) LONG FX-500 series FX-102 FAST (Lower value) H-SP STD 280 11.024 HYPR 990 38.976 STD 320 12.598 2m Bending (Note 4) HYPR 600 23.622 durability R4 Wide Beam Beam axis Ambient Protection Dimensions dia. temp. (mm) 610 24.016 435 17.126 160 6.299 50 1.969 85 3.346 185 7.283 -- (Note 3) 590 23.228 420 16.535 200 7.874 75 2.953 140 5.512 300 11.811 -- IP68G IP67 Applications -40 to +70 C Fiber Options P.64 Semi-custom fibers Sensing a wafer in corrosive environment FT-HL80Y FT-L80Y FT-Z802Y Vacuumresistant Liquid Leak / Liquid Detection Cleaning tank Wafer cassette Heatresistant -55 to P.63 +80 C Notes:1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut. 2) The sensing range is specified for white, non-glossy paper. 3) The fiber part is oil-resistant. 4) The allowable cutting range is 500 mm 19.685 in from the end that is inserted to the amplifier. Detecting wafer cassette in cleaning tank Chemical / Oilresistant Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Wafer Detecting a container at a chemical Piller Amplifiers FX-500 series FT-Z802Y FX-100 series INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 30 New product introduction Tough Fiber Fiber Selection Guide Model Heat-resistant It can be used under environments of -60 to +350 C -76 to +662 F. A joint type for wider workability is also available. Choose by shape/ application How to read Model No Earlier models comparison table Applications IC detection within a high temperature handler Detecting glass substrates FT-H20W-M1 Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type LIST OF FIBERS Thru-beam type (one pair set) HeatShape of fiber head Type resistant (mm) temp. Lens mountable (FX-LE1/LE2/SV1) Chemical / Oilresistant Heatresistant M4 o2.1 Heat-resistant Fiber Options 27 Allows flexible wiring Lens mountable (FX-LE1/LE2/SV1) 200 C Semi-custom fibers 130 C FT-H35-M2 30 350 C Sleeve Sleeve 60 60 mm mm Vacuumresistant Liquid Leak / Liquid Detection M4 Model No. M4 FT-H35-M2S6 Bending Fiber cable radius length (mm) : Free-cut R25 Fiber R25 Sleeve FT-H20W-M1 R10 1m M4 23 Lens mountable (FX-LE2 only) M4 FT-H20-M1 R25 FT-H13-FM2 2m 16 Lens mountable (FX-LE1/LE2/SV1) Fiber Dimensions FT-H20-J20-S (Note 5) Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Heat-resistant (joint) Thru-beam Type M4 23 FT-H20-J30-S (Note 5) FT-H20-J50-S (Note 5) 200 C Side-view o3.8 24 o4 STD 430 16.929 HYPR 1,200 47.244 880 34.646 670 26.378 170 6.693 250 9.843 490 19.291 80 3.150 o1.2 -60 to +350 C R10 23 Lens mountable (FX-LE1/LE2/SV1) 2m Sensing range (mm in) (Note 1) Beam FX-101 axis Ambient U-LG Dimensions (Upper value) dia. temp. LONG FX-500 series FX-102 FAST (mm) (Lower value) H-SP FT-H20-VJ50-S (Note 5) FT-H20-VJ80-S (Note 5) STD 1,000 39.370 470 18.504 840 33.071 300 11.811 HYPR (Note 2) 1,600 62.992 90 3.543 P.50 100 3.937 300 11.811 STD 1,300 51.181 540 21.260 960 37.795 210 8.268 330 12.992 540 21.260 HYPR (Note 2) 1,600 62.992 110 4.331 STD 1,900 74.803 700 27.559 1,300 51.181 250 9.843 410 16.142 700 27.559 HYPR 140 5.512 3,300 129.921 o0.8 -60 to +200 C o1.2 o1.5 -60 to P.49 +130 C o1.2 -60 to P.50 +200 C 200 mm (Note 3) Heatresistant side R18 (Note 4) 300 mm (Note 3) STD 1,000 39.370 470 18.504 790 31.102 135 5.315 300 11.811 420 16.535 HYPR 90 3.543 1,600 62.992 500 mm (Note 3) STD 800 mm (Note 3) 600 23.622 HYPR 2,100 82.677 1,300 51.181 980 38.583 150 5.906 390 15.354 500 19.685 120 4.724 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut). 4) Bending durable fiber R4 mm R0.157 in or more for ordinary temperature side. 5) Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set. 31 Heat-resistant joint fiber set contents New product introduction Heat-resistant side (-60 to +200 C -76 to +392 F) Ordinary temperature (-40 to +70 C -40 to +158 F) Tough Fiber Ordinary temperature side 100 mm 3.937 in approx. Amplifiers Fiber Selection Guide Model Heat-resistant side fiber Choose by shape/ application Ordinary temperature side fiber [FT-42 (Fiber cable length 2m, Free-cut)] Nut (resin) How to read Model No. Nut (metal), Use when securing to a mounting bracket. Earlier models comparison table Model No. when ordering individually as spare parts *Heat-resistant side fiber one pair set FT-H20-J20, FT-H20-J30, FT-H20-J50, FT-H20-VJ50, FT-H20-VJ80 Fibers Super Quality *Ordinary temperature side fiber one pair set FT-42 Threaded Type Square Head Type LIST OF FIBERS Cylindrical Type Reflective type HeatShape of fiber head Type resistant (mm) temp. Model No. Bending Fiber cable radius length (mm) : Free-cut Sensing range (mm in) (Note 1, 2) FX-101 Ambient U-LG Dimensions (Upper value) temp. LONG FX-500 series FX-102 FAST H-SP (Lower value) Coaxial M6 FD-H35-M2 25 2m o2.8 M6 350 C FD-H35-M2S6 22 Sleeve 90 mm Threaded M4 27 FD-H35-20S Fiber R25 Sleeve R10 Coaxial M6 200 C Heat-resistant o2.1 1m FD-H20-M1 28 Coaxial M4 FD-H20-21 27 130 C FD-H13-FM2 Glass substrate detection convergent reflective 21 FD-H30-L32 300 C R25 250 C 540 21.260 460 18.110 150 5.906 45 1.772 STD 260 10.236 HYPR 840 33.071 550 21.654 440 17.323 140 5.512 45 1.772 85 3.346 200 7.874 STD 550 21.654 500 19.685 200 7.874 55 2.165 120 4.724 300 11.811 500 19.685 380 14.961 130 5.118 45 1.772 90 3.543 280 11.024 640 25.197 600 23.622 200 7.874 65 2.559 100 3.937 -60 to 280 11.024 +130 C 330 12.992 HYPR 840 33.071 STD 230 9.055 HYPR 770 30.315 2m 350 13.780 HYPR 880 34.646 2m STD 17 0.669 HYPR 40 1.575 W19 x H27 x D5 W21 x H33.2 x D5 W21 x H34.5 x D5 FD-H25-L43 3m FD-H25-L45 FD-H18-L31 180 C W19 x H27 x D5 2m STD 1.5 to 26 0.059 to 1.024 HYPR 1 to 31 0.039 to 1.220 STD 5 to 42 0.197 to 1.654 HYPR 4 to 43.5 0.157 to 1.713 STD 16 0.630 HYPR 60 2.362 75 2.953 280 11.024 -60 to +350 C P.61 Retroreflective Type Heatresistant Vacuumresistant Liquid Leak / Liquid Detection -60 to +200 C 30 1.181 2 to 9 25 0.984 0.079 to 0.354 -60 to 12 0.472 0 to 17 +300 C 1.5 to 6 0.059 to 0.236 0 to 0.669 1 to 30 0.039 to 1.181 4 to 16 1 to 28 0.039 to 1.102 0.157 to 0.630 -20 to 1.5 to 24 0.059 to 0.945 4 to 23 +250 C 2 to 18 0.079 to 0.709 0.157 to 0.906 Ordinary 4 to 43 0.157 to 1.693 7 to 35 temp. side: 4.5 to 43 0.177 to 1.693 0.276 to 1.378 -20 to 5 to 40 0.197 to 1.575 7 to 38 +70 C 6.5 to 34 0.256 to 1.339 0.276 to 1.496 32 1.260 24 0.945 13 0.512 2 to 6.5 0.079 to 0.256 Convergent Reflective Type Chemical / Oilresistant 0 to 10 0 to 0.394 -60 to 0 to 25 +180 C 0 to 0.984 Notes: 1) The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in glass substrate for FD-H30-L32, FD-H18-L31, transparent glass 100 x 100 x t0.7 mm 3.937 x 3.937 x t0.028 in for FD-H25-L43 and FD-H25-L45). 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. FIBER OPTION Small Spot Wide Beam STD 260 10.236 HYPR 720 28.346 STD M6 Flat Type Narrow Beam R25 Sleeve 60 mm Sleeve P.60 Fiber Options Semi-custom fibers P.61 Fiber Dimensions Thru-beam Type P.60 Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series Lens (For thru-beam type fiber) P.42 INDEX 32 New product introduction Tough Fiber Vacuum-resistant Usable in high-temperatures of 300 C 572 F vacuum The leakage of FV-BR1 is still less than a very slight 1.33 x 10-10 Pa * m3/s [He], so that it can be used in vacuums with confidence. Fiber Selection Guide Model Choose by shape/ application Applications Highly resistant to repeated bending Detecting an FPD in vacuum chamber Vacuum resistant long range reflective fiber Vacuum resistant convergent reflective fiber Fibers FD-H30-KZ1V-S FD-H30-L32V-S How to read Model No Earlier models comparison table FT-H30-M1V-S Because it has a bending durability of over 100,000 times (R20 mm R0.787 in), it is highly resistant to repeated bending and is optimal for mounting on moving robot hand. FD-H30-KZ1V-S FD-H30-L32V-S Vacuum resistant expansion lens Super Quality FV-LE1 Threaded Type Vacuum resistant thru-beam fiber Square Head Type FT-H30-M1V-S Cylindrical Type Sleeve Flat Type Vacuum resistant thru-beam fiber Small Spot FT-H30-M1V-S Narrow Beam Vacuum resistant side-view lens FV-SV2 Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Thru-beam type (one pair set) Type Thru-beam Vacuumresistant LIST OF FIBERS Vacuumresistant Heatresistant Shape of fiber head (mm) 300 C Lens mountable (FV-LE1/SV2) M4 30 Model No. FT-H30-M1V-S (Note) Bending Fiber radius cable length (mm) R18 1m Sensing range (mm in) FX-500 series STD 270 10.630 HYPR 1,000 39.370 FX-101 (Upper value) FX-102 (Lower value) U-LG LONG FAST H-SP 590 23.228 470 18.504 160 6.299 55 2.165 110 4.331 280 11.024 Beam axis dia. (mm) Ambient temp. Dimensions o1.2 -30 to +300 C P.50 Note: Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Reflective type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Type Convergent Reflective reflective Thru-beam Type Vacuum-resistant Fiber Dimensions Shape of fiber head (mm) Model No. Bending Fiber radius cable length (mm) 300 C, Rectangular head W9.5 x H5.2 x D15 W19 x H5 x D27 U-LG LONG FAST H-SP FX-101 Ambient Dimensions (Upper value) temp. FX-102 (Lower value) 1m 10 to 340 0.394 to 13.386 25 to 80 20 to 200 0.787 to 7.874 15 to 270 0.591 to 10.630 0.984 to 3.150 20 to 120 0.787 to 4.724 10 to 220 HYPR 20 to 45 0.787 to 1.772 0.394 to 8.661 5 to 500 0.197 to 19.685 3m STD 8 0.315 HYPR 18 0.709 R18 FD-H30-L32V-S (Note 1) FX-500 series STD FD-H30-KZ1V-S (Note 1) 300 C, Glass substrate detection Sensing range (mm in)(Note 2) -30 to 12 0.472 2.5 to 6.5 +300 C 10 0.394 0.098 to 0.256 5.5 0.217 0 to 11 1.5 to 3 0.059 to 0.118 0 to 0.433 Notes:1) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 2) The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm 3.937 x 3.937 x t0.028 in. P.61 33 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. Vacuum-resistant fiber set contents Vacuum side Atmospheric side Earlier models comparison table Digital fiber sensor Fibers Vacuum resistant fibers Super Quality Atmospheric side fiber (FT-J8) Chamber wall or flange Threaded Type Photo-terminals (FV-BR1) Square Head Type (Recommended thickness: 3.0 to 20 mm 0.118 to 0.787 in) Cylindrical Type Model No. when ordering individually as spare parts Vacuum resistant fiber FT-H30-M1V (one pair set) FD-H30-KZ1V FD-H30-L32V Photo-terminal FV-BR1 (one pair set) Atmospheric side fiber FT-J8 (one pair set) Sleeve ounting bracket for FD-H30-KZ1V(-S) M MS-FD-2 Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type FIBER OPTIONS Retroreflective Type Lens (For thru-beam fiber) For thru-beam type fiber Designation Vacuum resistant expansion lens (Note 1) Model No. Chemical / Oilresistant Description Heatresistant Fiber Mode Liquid Leak / Liquid Detection FX-500 series Amplifier FV-LE1 HYPR U-LG LONG STD 3,600 3,600 3,400 1,500 FT-H30-M1V-S 141.732 141.732 133.858 59.055 (Note 2) Vacuum resistant side-view lens (Note 1) Vacuumresistant Increases the sensing range 4 times or more. * Ambient temperature: -60 to +350 C -76 to +662 F (Note 3) * Beam axis dia: o3.6 mm o0.142 in Sensing range (mm in) [Lens on both sides] (Note 4) (Note 2) FX-100 series FAST H-SP FX-101 FX-102 900 35.433 370 14.567 450 17.717 1,600 62.992 Beam axis is bent by 90. * Ambient temperature: -60 to +300 C -76 to +572 F (Note 3) * Beam axis dia: o3.7 mm o0.146 in Sensing range (mm in) [Lens on both sides] (Note 4) Fiber Mode Semi-custom fibers FX-500 series Amplifier FV-SV2 HYPR U-LG LONG STD 3,600 3,600 3,400 1,500 FT-H30-M1V-S 141.732 141.732 133.858 59.055 (Note 2) (Note 2) Fiber Options FX-100 series FAST H-SP FX-101 FX-102 900 35.433 370 14.567 450 17.717 1,600 62.992 Notes: 1) Be careful when installing the thru-beam type fiber equipped with the lens, as the beam envelope becomes narrow and alignment is difficult. 2) The fiber cable length practically limits the sensing range. 3) Refer to previous page for the ambient temperature of fibers to be used in combination. 4) The fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series, in FX-102 take into account the length of the FT-J8 atmospheric side fiber. Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 34 New product introduction Tough Fiber Fiber Selection Guide Liquid Leak / Liquid Detection It corresponds to various liquid events, from the contact (wetted) type to the pipe mounting type, and up to leak detection. Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type For detecting the upper limit of liquid surface level, sensor that receives beam when "liquid is absent" is recommended. For detecting the lower limit of liquid surface level, sensor that receives beam when "liquid is present" is recommended. The sensor will turn OFF during abnormal conditions (excess fluid, fiber disconnection, etc.)! Liquid absent: Beam received (Output ON) Liquid present / fiber is cutoff: Beam not received (Output OFF) The sensor will turn OFF during abnormal conditions (insufficient liquid, fiber disconnection, etc.) ! Liquid present: Beam received (Output ON) Liquid absent / fiber is cutoff: Beam not receired (Output OFF) FD-FA93 Vacuumresistant Liquid Leak / Liquid Detection Fiber Options FD-F41 FD-F41 FD-F4 Standard type FT-F93 FD-F4 For 1 mm 0.039 in thick pipes manufactured by PFA Full-protection type FD-HF40Y / FD-F41Y (Liquid level sensing) Metal-free FD-HF40Y Small diameter type R10 mm R0.394 in R10 mm R0.394 in Primary sheath: Polyethylene Secondary sheath: Fluorine resin 2,000 mm 78.740 in 2,000 mm 78.740 in (o4 mm o0.157 in) Bends easily with its small bending radius, protective tube is cuttable and extendable FD-F41Y Sheath: Polyethylene R20 mm R0.787 in R20 mm R0.787 in o4 mm o0.157 in protective tube (fluorine resin) o4 mm o0.157 in protective tube (fluorine resin) 500 mm 19.685 in (Cuttable*) Semi-custom fibers Fiber Dimensions Thru-beam (When used with the tying bands: o8 to o80 mm o0.315 to o3.150 in) Chemical / Oilresistant Heatresistant FT-F93 Strong against air bubbles Applicable pipe: Transparent pipe, Outer diameter o8 mm o0.315 in or more 500 mm 19.685 in (Cuttable*) Heat-resistant +105 C +221 F Heat-resistant +70 C +158 F Thru-beam Type Retroreflective Type * The range of 50 mm 1.969 in from the fiber tip cannot be cut. Also, fiber length can be extended using MS-FX-02Y (optional). Reflective Type Others Full-protection type FD-F71 (Liquid level sensing) SEMI S2 compliant Detect chemical leaks in semiconductor and LCD manufacturing processes. Amplifiers Compact, space-saving FX-500 series Side-mountable fiber head as slim as 10 mm 0.394 in is good to use in confined spaces. FX-100 series INDEX Ideal for use with chemicals and volatile materials This fiber type sensor is safer to use with volatile materials (SEMI S2 compliant). The fluorine resin fiber head makes it ideal for use with chemicals. 35 LIST OF FIBERS New product introduction Reflective type / Thru-beam type Liquid level sensing leak Liquid level sensing Liquid detection Contact type Type Shape of fiber head (mm) Heat resistant 125 C Fluorine resin coating o6 Heat resistant 105 C Fluorine resin coating Metal-free o4 Heat resistant 70 C Fluorine resin coating throughout the fiber Metal-free o4 SEMI S2 compliant W20 x H30 x D10 Bending radius (mm) Model No. Protective tube R40 Fiber R15 FD-F8Y o4 mm o0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam not received -40 to P.61 +105 C R20 Fiber 2m R10 (Note 2) 7RXJK R4 FD-F71 FX-101 FX-102 -40 to IP68 P.59 +125 C Protective tube FD-F41Y FX-500 series (STD mode) Ambient Protection Dimensions temp. o6 mm o0.236 in Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable) 2m Liquid surface not contacted: Beam received, (Note 1) Liquid surface contacted: Beam not received FD-HF40Y (Note 2) Description Fiber cable length : Free-cut 5m Bending durability o4 mm o0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam not received IP68G -40 to +70 C Liquid leak detection -20 to Leak absent: Beam received, Leak present: Beam interrupted IP67 +60 C Compatible amplifire: FX500 series only Liquid sensing Pipe-mountable type Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in P.59 transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, W25 x H13 x D20 FD-F41 glass, wall thickness 1 to 3 mm 0.039 to 0.118 in] Liquid absent: Beam received, Liquid present: Beam not received -40 to R10 For 1 mm thick PFA pipe +100 C Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PFA (fluorine resin) or equivalently FD-F4 W25 x H13 x D20 transparent pipe, wall thickness 1 mm 0.039 in] Liquid absent: Beam received, Liquid present: Beam not received Mountable on pipe*array fiber 7RXJK Applicable pipe diameter: Outer dia. o8 mm o0.315 in or more 2m -40 to transparent pipe (When used with the tying bands: o8 to o80 mm R4 W6.5 x H28.3 x D17 FD-FA93 o0.315 to o3.150 in) [PFA (fluorine resin), including translucent] +70 C Bending durability Liquid absent: Beam received, Liquid present: Beam not received SEMI S2 compliant Applicable pipe diameter: Outer dia. o3 to o10 mm o0.118 to IP40 Protective tube R20 7RXJK o0.394 in transparent pipe [PFA (fluorine resin) or equivalently Fiber -40 to transparent pipe, wall thickness 0.3 to 1 mm 0.012 to 0.039 in] P.49 FT-F93 +60 C R2 Liquid absent: Beam not received, Liquid present: Beam received W23 x H20 x D17 Bending durability Compatible amplifire: FX500 series only Notes:1) The allowable cutting range is 1,000 mm 39.370 in from the end that the amplifier inserted. 2) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint is available. Standard Accessories for additional supply MS-FD-F7-1 (SUS mounting bracket for FD-F71) MS-FD-F7-2 (PVC mounting bracket for FD-F71) FIBER OPTIONS Model No. MS-FX-01Y Protective tube extension joint (Note) Fiber mounting joint (Note) MS-FX-02Y MS-FX-03Y MS-FX-01Y *MS-FX-01Y MS-FX-01Y This joint suppresses false operations due to liquid slip-in from the top of the protective tube. FD-HF40Y FD-F41Y The protective tube can be extended. Ferrule (MS-FX-YF) Body Applications Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant MS-FX-02Y *MS-FX-02Y MS-FX-02Y Union nut Semi-custom fibers Fiber mounting MS-FX-03Y MS-FX-03Y *MS-FX-03Y MS-FX-03Y joint Union nut Union nut Ferrule (MS-FX-YF) Union nut Ferrule (MS-FX-YF) Ferrule (MS-FX-YF) Detecting liquid level in a tank Fiber Options The joint is used for mounting fibers on a tank. Protective tube extension joint MS-FX-02Y Body Body Ferrule Union nut(MS-FX-YF) Ferrule (MS-FX-YF) Union nut Union nut Model Description Note: The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage. Liquid inflow prevention joint MS-FX-01Y Fiber Selection Guide Liquid Leak / Liquid Detection Applicable fibers Designation Liquid inflow prevention joint (Note) Tough Fiber Body Ferrule (MS-FX-YF) Body Body Ferrule Union nut(MS-FX-YF) Ferrule (MS-FX-YF) Union nut Union nut Union nut Ferrule (MS-FX-YF) Union nut Ferrule (MS-FX-YF) Body Ferrule (MS-FX-YF) Body Body Leak detection for use in semiconductor device manufacturing Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series FD-F71 INDEX 7RXJK : Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180) and more flexible (bending radius: R4 mm R0.157 in or less) features. 36 New product introduction Tough Fiber Fibers are listed in alphabetic order. Refer to p. 2~ for details of each fiber. SENSING RANGE Thru-beam type (one pair set) Sensing range (mm in) (Note 1) Fiber Selection Guide HYPR Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX FX-500 series Model No. U-LG LONG STD FX-100 series FAST H-SP FX-101 FX-102 19,600 19,600 19,600 19,600 16,000 6,300 14,000 19,600 FT-140 771.652 (Note 2) 771.652 (Note 2) 771.652 (Note 2) 771.652 (Note 2) 629.920 248.031 551.180 771.652 (Note 2) 1,350 810 650 400 210 75 135 400 FT-30 53.150 31.890 25.591 15.748 8.268 2.953 5.315 15.748 1,350 770 550 315 210 70 130 340 FT-31 53.150 30.315 21.654 12.402 8.268 2.756 5.118 13.386 1,220 740 550 315 195 63 130 340 FT-31S 48.031 29.134 21.654 12.402 7.677 2.480 5.118 13.386 990 590 440 260 150 53 80 240 FT-31W 38.976 23.228 17.323 10.236 5.906 2.087 3.150 9.449 3,600 2,200 1,700 1,200 530 190 320 870 FT-40 141.732 (Note 2) 86.614 66.929 47.244 20.866 7.480 12.598 34.252 3,600 2,050 1,600 1,130 530 190 300 800 FT-42 141.732 (Note 2) 80.709 62.992 44.488 20.866 7.480 11.811 31.496 3,600 2,050 1,600 1,130 530 190 300 800 FT-42S 141.732 (Note 2) 80.709 62.992 44.488 20.866 7.480 11.811 31.496 3,300 1,900 1,400 800 490 160 260 720 FT-42W 129.921 74.803 55.118 31.496 19.291 6.299 10.236 28.346 3,600 2,800 2,100 1,400 770 240 350 970 FT-43 141.732 (Note 2) 110.236 82.677 55.118 30.315 9.449 13.780 38.189 1,600 1,600 1,600 1,200 630 200 340 920 FT-45X 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 47.244 24.803 7.874 13.386 36.220 3,600 3,600 3,600 3,600 3,600 1,100 1,900 3,600 FT-A11 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 43.307 74.803 141.732 (Note 2) 3,600 3,600 3,600 3,600 3,600 1,300 1,700 3,400 FT-A11W 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 51.181 66.929 133.858 3,600 3,600 3,600 3,600 3,600 2,100 3,600 3,600 FT-A32 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 82.677 141.732 (Note 2) 141.732 (Note 2) 3,600 3,600 3,600 3,600 3,600 3,000 3,600 3,600 FT-A32W 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 118.110 141.732 (Note 2) 141.732 (Note 2) 2,300 1,550 1,500 860 500 170 250 660 FT-AL05 90.551 61.024 59.055 33.858 19.685 6.693 9.843 25.984 52 30 24 15 8 2 6 19 FT-E13 2.047 1.181 0.945 0.591 0.315 0.079 0.236 0.748 270 160 125 75 42 13 22 80 FT-E23 10.630 6.299 4.921 2.953 1.654 0.512 0.866 3.150 Applicable pipe diameter: Outer dia. o3 to o10 mm o0.118 to o0.394 in transparent pipe [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 0.3 to 1 mm 0.012 to 0.039 in] FT-F93 Liquid absent: Beam interrupted, Liquid present: Beam received Compatible amplifier: FX-500 series only 3,300 1,900 1,300 700 410 140 250 700 FT-H13-FM2 129.921 74.803 51.181 27.559 16.142 5.512 9.843 27.559 1,600 1,000 790 470 300 90 135 420 FT-H20-J20-S (Note 3) 62.992 39.370 31.102 18.504 11.811 3.543 5.315 16.535 1,600 1,000 790 470 300 90 135 420 FT-H20-J30-S (Note 3) 62.992 39.370 31.102 18.504 11.811 3.543 5.315 16.535 1,600 1,000 790 470 300 90 135 420 FT-H20-J50-S (Note 3) 62.992 39.370 31.102 18.504 11.811 3.543 5.315 16.535 1,600 1,300 960 540 330 110 210 540 FT-H20-M1 62.992 (Note 2) 51.181 37.795 21.260 12.992 4.331 8.268 21.260 2,100 1,300 980 600 390 120 150 500 FT-H20-VJ50-S (Note 3) 82.677 51.181 38.583 23.622 15.354 4.724 5.906 19.685 2,100 1,300 980 600 390 120 150 500 FT-H20-VJ80-S (Note 3) 82.677 51.181 38.583 23.622 15.354 4.724 5.906 19.685 1,600 1,000 840 470 300 90 100 300 FT-H20W-M1 62.992 (Note 2) 39.370 33.071 18.504 11.811 3.543 3.937 11.811 1,000 590 470 270 160 55 110 280 FT-H30-M1V-S (Note 4) 39.370 23.228 18.504 10.630 6.299 2.165 4.331 11.024 1,200 880 670 430 250 80 170 490 FT-H35-M2 47.244 34.646 26.378 16.929 9.843 3.150 6.693 19.291 1,200 880 670 430 250 80 170 490 FT-H35-M2S6 47.244 34.646 26.378 16.929 9.843 3.150 6.693 19.291 3,600 3,600 3,600 3,600 2,300 740 990 2,340 FT-HL80Y 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 90.551 29.134 38.976 92.126 3,600 3,600 3,600 3,600 3,600 1,200 2,200 3,600 FT-KS40 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 47.244 86.614 141.732 (Note 2) 2,500 1,600 1,200 710 440 160 135 560 FT-KV26 98.425 62.992 47.244 27.953 17.323 6.299 5.315 22.047 3,600 3,600 3,600 3,600 3,600 1,200 2,200 3,600 FT-KV40 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 47.244 86.614 141.732 (Note 2) 3,600 3,600 3,600 3,600 3,100 940 2,200 3,600 FT-KV40W 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 122.047 37.008 86.614 141.732 (Note 2) 3,600 3,600 3,600 3,600 2,800 920 1,100 2,600 FT-L80Y 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 110.236 36.220 43.307 102.362 1,000 580 440 270 160 55 100 340 FT-R31 39.370 22.835 17.323 10.630 6.299 2.165 3.937 13.386 3,600 1,750 1,500 930 500 160 270 740 FT-R40 141.732 (Note 2) 68.898 59.055 36.614 19.685 6.299 10.630 29.134 3,200 1,800 1,400 800 460 150 250 710 FT-R41W 125.984 70.866 55.118 31.496 18.110 5.906 9.843 27.953 3,600 3,600 3,500 2,200 1,300 460 510 2,000 FT-R42W 141.732 (Note 2) 141.732 (Note 2) 137.795 86.614 51.181 18.110 20.079 78.740 Notes: 1) 2) 3) 4) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. The fiber cable length practically limits the sensing range. Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set. Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Dimensions P.48 P.48 P.48 P.48 P.48 P.48 P.48 P.48 P.48 P.48 P.49 P.49 P.49 P.49 P.49 P.49 P.49 P.49 P.49 P.49 P.50 P.50 P.50 P.50 P.50 P.50 P.50 P.50 P.50 P.50 P.50 P.51 P.51 P.51 P.51 P.51 P.51 P.51 P.51 P.51 37 Fibers are listed in alphabetic order. Refer to p. 2~ for details of each fiber. SENSING RANGE New product introduction Tough Fiber Thru-beam type (one pair set) Sensing range (mm in) (Note 1) FX-500 series Model No. FT-R43 FT-R44Y FT-R60Y FT-S11 FT-S20 FT-S21 FT-S21W FT-S30 FT-S31W FT-S32 FT-V23 FT-V24W FT-V25 FT-V30 FT-V40 FT-V80Y FT-Z20HBW FT-Z20W FT-Z30 FT-Z30E FT-Z30EW FT-Z30H FT-Z30HW FT-Z30W FT-Z40HBW FT-Z40W FT-Z802Y HYPR U-LG LONG 3,000 118.110 3,000 118.110 3,600 141.732 (Note 2) 350 13.780 1,350 53.150 1,350 53.150 990 38.976 3,600 141.732 (Note 2) 3,300 129.921 3,600 141.732 (Note 2) 1,800 70.866 380 14.961 900 35.433 2,200 86.614 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,100 43.307 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,300 129.921 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 1,600 62.992 3,600 141.732 (Note 2) 210 8.268 810 31.890 770 30.315 590 23.228 2,200 86.614 1,900 74.803 3,600 141.732 (Note 2) 1,000 39.370 230 9.055 550 21.654 1,200 47.244 3,600 141.732 (Note 2) 2,800 110.236 670 26.378 1,500 59.055 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,300 129.921 1,900 74.803 3,300 129.921 3,600 141.732 (Note 2) 1,100 43.307 1,100 43.307 3,600 141.732 (Note 2) 160 6.299 650 25.591 550 21.654 440 17.323 1,700 66.929 1,400 55.118 3,600 141.732 (Note 2) 880 34.646 200 7.874 480 18.898 1,000 39.370 3,600 141.732 (Note 2) 2,200 86.614 570 22.441 1,100 43.307 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,200 125.984 1,400 55.118 2,300 90.551 3,600 141.732 (Note 2) FX-100 series STD 720 28.346 720 28.346 2,100 82.677 90 3.543 400 15.748 315 12.402 260 10.236 1,200 47.244 800 31.496 3,100 122.047 450 17.717 110 4.331 240 9.449 680 26.772 3,500 137.795 1,300 51.181 260 10.236 620 24.409 2,100 82.677 3,500 137.795 3,400 133.858 3,500 137.795 3,500 137.795 1,500 59.055 800 31.496 1,500 59.055 3,100 122.047 FAST 430 16.929 430 16.929 1,260 49.606 60 2.362 210 8.268 210 8.268 150 5.906 530 20.866 490 19.291 1,800 70.866 280 11.024 60 2.362 140 5.512 340 13.386 2,400 94.488 800 31.496 180 7.087 420 16.535 1,200 47.244 2,400 94.488 2,000 78.740 2,600 102.362 2,600 102.362 1,000 39.370 490 19.291 900 35.433 1,900 74.803 H-SP 130 5.118 130 5.118 400 15.748 19 0.748 75 2.953 70 2.756 53 2.087 190 7.480 160 6.299 600 23.622 90 3.543 20 0.787 45 1.772 100 3.937 850 33.465 240 9.449 55 2.165 130 5.118 410 16.142 740 29.134 630 24.803 810 31.890 810 31.890 280 11.024 160 6.299 290 11.417 470 18.504 FX-101 210 8.268 210 8.268 690 27.165 40 1.575 135 5.315 130 5.118 80 3.150 320 12.598 260 10.236 1,100 43.307 160 6.299 35 1.378 95 3.740 180 7.087 1,000 39.370 340 13.386 100 3.937 280 11.024 710 27.953 1,200 47.244 1,400 55.118 1,400 55.118 1,400 55.118 540 21.260 260 10.236 410 16.142 520 20.472 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. Dimensions FX-102 640 25.197 640 25.197 1,890 74.409 90 3.543 400 15.748 340 13.386 240 9.449 870 34.252 720 28.346 3,000 118.110 400 15.748 90 3.543 260 10.236 480 18.898 3,100 122.047 800 31.496 320 12.598 730 28.740 2,300 90.551 3,200 125.984 2,600 102.362 3,200 125.984 3,200 125.984 1,800 70.866 720 28.346 1,200 47.244 3,100 122.047 Fiber Selection Guide Model P.51 P.52 P.52 P.52 Choose by shape/ application How to read Model No. Earlier models comparison table P.52 P.52 P.52 P.52 P.52 Fibers Super Quality Threaded Type P.52 Square Head Type P.52 Cylindrical Type P.53 Sleeve P.53 Flat Type P.53 P.53 P.53 P.53 Small Spot Narrow Beam Wide Beam P.53 Convergent Reflective Type P.53 Retroreflective Type P.53 Chemical / Oilresistant P.54 P.54 P.54 P.54 Heatresistant Vacuumresistant Liquid Leak / Liquid Detection P.54 P.54 P.54 Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 38 New product introduction Tough Fiber Fibers are listed in alphabetic order. Refer to p. 2~ for details of each fiber. SENSING RANGE Retroreflective type Sensing range (mm in) (Note 1, 2) Fiber Selection Guide FX-500 series Model No. HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 15 to 570 0.591 to 22.441 20 to 1,000 0.787 to 39.370 20 to 1,000 0.787 to 39.370 100 to 1,900 3.937 to 74.803 15 to 460 0.591 to 18.110 20 to 800 0.787 to 31.496 20 to 800 0.787 to 31.496 100 to 1,400 3.937 to 55.118 15 to 410 0.591 to 16.142 20 to 400 0.787 to 15.748 20 to 400 0.787 to 15.748 100 to 1,200 3.937 to 47.244 15 to 310 0.591 to 12.205 20 to 300 0.787 to 11.811 20 to 300 0.787 to 11.811 100 to 990 3.937 to 38.976 15 to 220 0.591 to 8.661 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 100 to 780 3.937 to 30.709 15 to 100 0.591 to 3.937 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 100 to 490 3.937 to 19.291 15 to 200 0.591 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 100 to 550 3.937 to 21.654 15 to 360 0.591 to 14.173 20 to 350 0.787 to 13.780 20 to 350 0.787 to 13.780 100 to 830 3.937 to 32.677 Model Choose by shape/ application FR-KZ22E How to read Model No FR-KZ50E Earlier models comparison table FR-KZ50H FR-Z50HW Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Small Spot RF-230 Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX P.55 P.55 P.55 P.55 Sensing range when FR-Z50HW is used in combination with a reflector (optional) Reflector Model No. Wide Beam Dimensions Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. The sensing range of FR-Z50HW is specified for the RF-13. The sensing range of FR-KZ50H and FR-KZ50E is specified for the attached reflector RF-003. The sensing range of FR-KZ22E is specified for the attached reflector. 2) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. Flat Type Narrow Beam FX-100 series RF-220 RF-210 HYPR U-LG Sensing range (mm in) FX-500 series LONG STD FAST H-SP 100 to 19,000 100 to 8,000 100 to 5,000 100 to 3,600 100 to 2,900 100 to 1,400 3.937 to 748.03 3.937 to 314.960 3.937 to 196.850 3.937 to 141.732 3.937 to 114.173 3.937 to 55.118 100 to 8,000 100 to 4,700 100 to 3,500 100 to 3,000 100 to 1,800 100 to 830 3.937 to 314.960 3.937 to 185.039 3.937 to 137.795 3.937 to 118.110 3.937 to 70.866 3.937 to 32.677 100 to 5,500 100 to 2,700 100 to 2,400 100 to 1,500 100 to 1,200 100 to 530 3.937 to 216.535 3.937 to 106.299 3.937 to 94.488 3.937 to 59.055 3.937 to 47.244 3.937 to 20.866 FX-100 series FX-101 FX-102 100 to 2,400 100 to 5,000 3.937 to 94.488 3.937 to 196.850 100 to 1,300 100 to 2,600 3.937 to 51.181 3.937 to 102.362 100 to 980 100 to 1,300 3.937 to 38.583 3.937 to 51.181 Note: 1) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than 100 mm 3.937 in. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. 39 Fibers are listed in alphabetic order. Refer to p. 2~ for details of each fiber. SENSING RANGE New product introduction Tough Fiber Reflective type Sensing range (mm in) (Note 1, 2) FX-500 series Model No. HYPR FD-30 FD-31 FD-31W FD-32G FD-32GX FD-40 FD-41 FD-41S FD-41SW FD-41W FD-42G FD-42GW FD-60 FD-61 FD-61G FD-61S FD-61W FD-62 FD-64X 600 23.622 515 20.276 330 12.992 650 25.591 630 24.803 600 23.622 515 20.276 515 20.276 330 12.992 900 35.433 650 25.591 670 26.378 1,550 61.024 1,400 55.118 1,100 43.307 1,200 47.244 900 35.433 1,500 59.055 670 26.378 FD-A16 FD-AL11 FD-E13 FD-E23 FD-EG30 FD-EG30S FD-EG31 FD-F4 670 26.378 50 1.969 170 6.693 170 6.693 170 6.693 85 3.346 U-LG LONG STD FX-100 series FAST H-SP FX-101 330 250 160 80 25 45 12.992 9.843 6.299 3.150 0.984 1.772 290 220 125 80 25 35 11.417 8.661 4.921 3.150 0.984 1.378 180 140 80 45 12 15 7.087 5.512 3.150 1.772 0.472 0.591 380 270 200 95 27 70 14.961 10.630 7.874 3.740 1.063 2.756 410 360 200 100 30 75 16.142 14.173 7.874 3.937 1.181 2.953 330 250 160 80 25 45 12.992 9.843 6.299 3.150 0.984 1.772 290 220 125 80 25 35 11.417 8.661 4.921 3.150 0.984 1.378 290 220 125 80 25 35 11.417 8.661 4.921 3.150 0.984 1.378 180 140 80 45 12 15 7.087 5.512 3.150 1.772 0.472 0.591 630 430 270 150 45 80 24.803 16.929 10.630 5.906 1.772 3.150 380 270 200 95 27 70 14.961 10.630 7.874 3.740 1.063 2.756 340 280 150 90 25 45 13.386 11.024 5.906 3.543 0.984 1.772 900 740 520 260 90 140 35.433 29.134 20.472 10.236 3.543 5.512 840 670 450 200 70 120 33.071 26.378 17.717 7.874 2.756 4.724 800 650 420 200 60 120 31.496 25.591 16.535 7.874 2.362 4.724 790 660 420 220 75 130 31.102 25.984 16.535 8.661 2.953 5.118 630 430 270 150 45 80 24.803 16.929 10.630 5.906 1.772 3.150 1,000 940 520 340 110 170 39.370 37.008 20.472 13.386 4.331 6.693 500 410 280 160 50 75 19.685 16.142 11.024 6.299 1.969 2.953 200 200 200 140 75 120 7.874 7.874 7.874 5.512 2.953 4.724 530 510 320 180 50 100 20.866 20.079 12.598 7.087 1.969 3.937 29 25 12 7 2 5 1.142 0.984 0.472 0.276 0.079 0.197 120 80 55 30 9 20 4.724 3.150 2.165 1.181 0.354 0.787 130 110 48 30 9 20 5.118 4.331 1.890 1.181 0.354 0.787 110 80 50 30 9 20 4.331 3.150 1.969 1.181 0.354 0.787 45 35 20 12 3.5 7 1.772 1.378 0.787 0.472 0.138 0.276 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in] Liquid absent: Beam received, Liquid present: Beam interrupted Dimensions FX-102 155 6.102 140 5.512 60 2.362 190 7.480 210 8.268 155 6.102 140 5.512 140 5.512 60 2.362 230 9.055 190 7.480 140 5.512 420 16.535 410 16.142 350 13.780 360 14.173 230 9.055 450 17.717 220 8.661 240 9.449 285 11.220 15 0.591 70 2.756 70 2.756 70 2.756 25 0.984 Model P.56 P.56 P.56 P.56 P.56 P.56 P.56 P.56 Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type P.57 Cylindrical Type P.57 Sleeve P.57 Flat Type P.57 P.57 P.57 P.57 Small Spot Narrow Beam Wide Beam P.57 Convergent Reflective Type P.58 Retroreflective Type P.58 Chemical / Oilresistant P.58 Heatresistant P.58 P.58 P.58 Vacuumresistant Liquid Leak / Liquid Detection P.59 P.59 Fiber Options P.59 o4 mm o0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.59 FD-F71 Liquid leak detection Leak absent: Beam received, Leak present: Beam interrupted Compatible amplifier: FX-500 series only P.59 FD-F8Y o6 mm o0.236 in Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted P.59 FD-FA93 Applicable pipe diameter: Outer dia. o8 mm o0.315 in or more transparent pipe (When used with the tying bands: o8 to o80 mm o0.315 to o3.150 in) [PFA (fluorine resin), including translucent] Liquid absent: Beam received, Liquid present: Beam interrupted P.59 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper. 3) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to page 35 for details. How to read Model No. P.56 P.59 FD-F41Y (Note 3) Choose by shape/ application P.56 Applicable pipe diameter: Outer dia. o6 to o26 mm o0.236 to o1.024 in transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in] Liquid absent: Beam received, Liquid present: Beam interrupted FD-F41 Fiber Selection Guide Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 40 New product introduction Tough Fiber Fibers are listed in alphabetic order. Refer to p. 2~ for details of each fiber. SENSING RANGE Reflective type Sensing range (mm in) (Note 1, 2) Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam HYPR FD-HF40Y (Note 5) FD-L10 (Note 3) FD-L11 (Note 3) FD-L12W (Note 3) FD-L20H Retroreflective Type FD-L21 (Note 3) Chemical / Oilresistant FD-L21W (Note 3) Vacuumresistant Liquid Leak / Liquid Detection FD-L22A (Note 3) FD-L23 (Note 3) FD-L30A (Note 3) FD-L31A (Note 3) FD-L32H (Note 3) Fiber Options FD-R31G FD-R32EG FD-R33EG Semi-custom fibers FD-R34EG FD-R41 FD-R60 Fiber Dimensions FD-R61Y Thru-beam Type FD-S21 Retroreflective Type FD-S30 Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX U-LG LONG STD FX-100 series FAST 880 640 600 350 200 FD-H13-FM2 25.197 23.622 13.780 7.874 34.646 60 32 24 16 13 FD-H18-L31 2.362 1.260 0.945 0.630 0.512 770 500 380 230 130 FD-H20-21 30.315 19.685 14.961 9.055 5.118 840 550 500 330 200 FD-H20-M1 33.071 21.654 19.685 12.992 7.874 1 to 31 1 to 30 1 to 28 1.5 to 26 1.5 to 24 FD-H25-L43 (Note 3) 0.039 to 1.220 0.039 to 1.181 0.039 to 1.102 0.059 to 1.024 0.059 to 0.945 4 to 43.5 4 to 43 4.5 to 43 5 to 42 5 to 40 FD-H25-L45 (Note 3) 0.157 to 1.713 0.157 to 1.693 0.177 to 1.693 0.197 to 1.654 0.197 to 1.575 to 500 10 to 340 15 to 270 20 to 200 20 to120 FD-H30-KZ1V-S (Note 3, 4) 0.197 to519.685 0.394 to 13.386 0.591 to 10.630 0.787 to 7.874 0.787 to 4.724 40 30 25 17 12 FD-H30-L32 1.575 1.181 0.984 0.669 0.472 18 12 10 8 5.5 FD-H30-L32V-S (Note 3, 4) 0.709 0.472 0.394 0.315 0.217 840 550 440 260 140 FD-H35-20S 33.071 21.654 17.323 10.236 5.512 720 540 460 260 150 FD-H35-M2 28.346 21.260 18.110 10.236 5.906 720 540 460 260 150 FD-H35-M2S6 28.346 21.260 18.110 10.236 5.906 Convergent Reflective Type Heatresistant FX-500 series Model No. FD-S31 FD-S32 FX-101 H-SP 65 2.559 2 to 6.5 0.079 to 0.256 45 1.772 55 2.165 2 to 18 0.079 to 0.709 6.5 to 34 0.256 to 1.339 20 to 45 0.787 to 1.772 1.5 to 6 0.059 to 0.236 1.5 to 3 0.059 to 0.118 45 1.772 45 1.772 45 1.772 FX-102 100 280 3.937 11.024 0 to 10 0 to 25 0 to 0.394 0 to 0.984 90 280 3.543 11.024 120 300 4.724 11.811 4 to 16 4 to 23 0.157 to 0.630 0.157 to 0.906 7 to 35 7 to 38 0.276 to 1.378 0.276 to 1.496 25 to 80 10 to 220 0.984 to 3.150 0.394 to 8.661 2 to 9 0 to 17 0.079 to 0.354 0 to 0.669 2.5 to 6.5 0 to11 0.098 to 0.256 0 to 0.433 85 200 3.346 7.874 75 280 2.953 11.024 75 280 2.953 11.024 o4 mm o0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam not received 0 to 6 0 to 5.5 0 to 5.5 0 to 5 0 to 4.5 0 to 0.236 0 to 0.217 0 to 0.217 0 to 0.197 0 to 0.177 0 to 11.5 0 to 10.5 0 to 10 0 to 9.5 0 to 9 0 to 0.453 0 to 0.413 0 to 0.394 0 to 0.374 0 to 0.354 14 12.5 12 8 0.5 to 7 0.551 0.492 0.472 0.315 0.020 to 0.276 45 35 32 23 2 to 15 1.772 1.378 1.260 0.906 0.079 to 0.591 1 to 19 1 to 18 1 to 18 1.5 to 16 2 to 15 0.039 to 0.748 0.039 to 0.709 0.039 to 0.709 0.059 to 0.630 0.079 to 0.591 1.5 to 15 2 to 15 2 to 15 3 to 14 4 to 14 0.059 to 0.591 0.079 to 0.591 0.079 to 0.591 0.118 to 0.551 0.158 to 0.551 0 to 31 0 to 28 0 to 27 0 to 24 0 to 24 0 to 1.220 0 to 1.102 0 to 1.063 0 to 0.945 0 to 0.945 0 to 30 0 to 30 0 to 30 0 to 29 0 to 28 0 to 1.181 0 to 1.181 0 to 1.181 0 to 1.142 0 to 1.102 0 to 43 0 to 43 0 to 43 0 to 43 0 to 42 0 to 1.693 0 to 1.693 0 to 1.693 0 to 1.693 0 to 1.654 3 to 35 4 to 33 4 to 33 4 to 33 4 to 32 0.118 to 1.378 0.157 to 1.299 0.157 to 1.299 0.157 to 1.299 0.157 to 1.260 0 to 110 0 to 87 0 to 74 0 to 56 1 to 38 0 to 4.331 0 to 3.425 0 to 2.913 0 to 2.205 0.039 to 1.496 530 310 260 170 85 20.866 12.205 10.236 6.693 3.346 170 110 92 45 30 6.693 4.331 3.622 1.772 1.181 84 44 33 19 11 3.307 1.732 1.299 0.748 0.433 130 90 70 38 23 5.118 3.543 2.756 1.496 0.906 710 430 320 210 100 27.953 16.929 12.598 8.268 3.937 1,100 600 550 290 190 43.307 23.622 21.654 11.417 7.480 160 990 610 435 280 11.024 6.299 38.976 24.016 17.126 190 130 110 80 37 7.480 5.118 4.331 3.150 1.457 600 330 250 160 80 23.622 12.992 9.843 6.299 3.15 515 290 220 125 80 20.276 11.417 8.661 4.921 3.15 1,200 790 660 420 220 47.244 31.102 25.984 16.535 8.661 0 to 4 0 to 0.157 0 to 8 0 to 0.315 0.5 to 4 0.020 to 0.157 5 to 9 0.197 to 0.354 3 to 12 0.118 to 0.472 6.5 to 10 0.256 to 0.394 0 to 18 0 to 0.709 1.5 to 24 0.059 to 0.945 0 to 29 0 to 1.142 5 to 25 0.197 to 0.984 27 1.063 9 0.354 3 0.118 7 0.276 34 1.339 65 2.559 50 1.969 11 0.433 25 0.984 25 0.984 75 2.953 0 to 4.5 0 to 0.177 0 to 8 0 to 0.315 1 to 4.5 0.039 to 0.177 5 to 15 0.197 to 0.591 3 to 15 0.118 to 0.591 7 to 12 0.276 to 0.472 0 to 19 0 to 0.748 0 to 28 0 to 1.102 0 to 40 0 to 1.575 5 to 30 0.197 to 1.181 16 to 30 0.630 to 1.181 45 1.772 20 0.787 7 0.276 17 0.669 60 2.362 110 4.331 85 3.346 25 0.984 45 1.772 35 1.378 120 4.724 Dimensions P.60 P.60 P.60 P.60 P.60 P.60 P.61 P.61 P.61 P.61 P.61 P.61 P.61 0 to 5.5 0 to 0.217 0 to 9 0 to 0.354 0.5 to 7 0.020 to 0.276 1 to 30 0.039 to 1.181 1.5 to 16 0.059 to 0.630 3 to 14 0.118 to 0.551 0 to 25 0 to 0.984 0 to 30 0 to 1.181 0 to 50 0 to 1.969 4 to 33 0.157 to 1.299 0 to 50 0 to 1.969 150 5.906 68 2.677 22 0.866 60 2.362 170 6.693 240 9.449 185 7.283 70 2.756 155 6.102 140 5.512 345 13.583 P.62 P.62 P.62 P.62 P.62 P.62 P.62 P.62 P.62 P.62 P.63 P.63 P.63 P.63 P.63 P.63 P.63 P.63 P.63 P.64 P.64 P.64 Notes: 1) N ote that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range of reflective type is the value for white non-glossy paper (as for FD-H30-L32 and FD-H18-L31 50 x 50 mm 1.969 x 1.969 in glass substrate). 3) The sensing range is specified for transparent glass 100 x 100 x t0.7 mm 3.937 x 3.937 x t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm t0.079 in) [FD-L10: silicon wafers 100 x 100 mm 3.937 x 3.937 in]. 4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 5) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to page 35 for details. 41 Fibers are listed in alphabetic order. Refer to p. 2~ for details of each fiber. SENSING RANGE New product introduction Tough Fiber Reflective type Sensing range (mm in) (Note 1, 2) FX-500 series Model No. HYPR FD-S32W FD-S33GW FD-S60Y FD-V30 FD-V30W FD-V50 FD-Z20HBW FD-Z20W FD-Z40HBW FD-Z40W FD-Z50HW (Note 3) U-LG LONG STD FX-100 series FAST H-SP 900 630 430 270 150 45 35.433 24.803 16.929 10.630 5.906 1.772 670 340 280 150 90 25 26.378 13.386 11.024 5.906 3.543 0.984 600 590 420 320 200 75 23.622 23.228 16.535 12.598 7.874 2.953 240 130 120 65 35 14 9.449 5.118 4.724 2.559 1.378 0.551 80 40 30 20 10 2 3.150 1.575 1.181 0.787 0.394 0.079 370 220 210 120 75 25 14.567 8.661 8.268 4.724 2.953 0.984 1 to 340 1 to 210 1 to 180 2 to 85 2 to 55 3 to 15 0.039 to 13.386 0.039 t 8.268 0.039 to 7.087 0.079 to 3.346 0.079 to 2.165 0.118 to 0.591 260 150 130 1 to 65 2 to 45 5 to 13 10.236 5.906 5.118 0.039 to 2.559 0.079 to 1.772 0.197 to 0.512 760 540 470 260 1 to 160 2 to 50 29.921 21.260 18.504 10.236 0.039 to 6.299 0.079 to 1.969 790 440 390 190 1 to 120 2 to 35 31.102 17.323 15.354 7.480 0.039 to 4.724 0.079 to 1.378 10 to 2,500 10 to 1,100 10 to 1,000 10 to 650 10 to 410 15 to 130 0.394 to 98.425 0.394 to 43.307 0.394 to 39.370 0.394 to 25.591 0.394 to 16.142 0.591 to 5.118 FX-101 FX-102 80 3.150 45 1.772 140 5.512 25 0.984 6 0.236 40 1.575 2 to 30 0.079 to 1.181 2 to 32 0.079 to 1.260 1 to 90 0.039 to 3.543 1 to 74 0.039 to 2.913 10 to 200 0.394 to 7.874 230 9.055 140 5.512 300 11.811 75 2.953 20 0.787 100 3.937 1 to 90 0.039 to 3.543 1 to 80 0.039 to 3.150 0.5 to 240 0.020 to 9.449 200 7.874 10 to 530 0.394 to 20.866 Dimensions Fiber Selection Guide Model P.64 P.64 P.64 P.64 Choose by shape/ application How to read Model No. Earlier models comparison table P.64 P.65 P.65 P.65 P.65 Fibers Super Quality Threaded Type P.65 Square Head Type P.65 Cylindrical Type Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The sensing range is specified for white non-glossy paper (except for FD-Z50HW). 3) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. Refer to P.38 for the sensing range when FR-Z50HW is used in combination with a reflector (optional). Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 42 New product introduction Tough Fiber FIBER OPTIONS Refer to p.66~ for details of lens dimensions. Lens (For thru-beam type fiber) Designation Model No. Description Increases the sensing range by 5 times or more. * Ambient temperature: -60 to +350 C -76 to +662 F (Note 4) * Beam dia: o3.6 mm o0.142 in Sensing range (mm in) [Lens on both sides] Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table FT-43 FX-500 series HYPR U-LG LONG STD FAST 3,600 3,600 3,600 3,600 3,600 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) H-SP 1,600 62.992 FX-100 series FX-101 FX-102 2,400 3,600 94.488 141.732 (Note 2) FT-42 FT-42W 3,600 3,600 3,600 3,600 3,600 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 2,200 86.614 3,400 3,600 133.858 141.732 (Note 2) FT-45X 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) 1,500 1,600 1,600 59.055 62.992 (Note 2) 62.992 (Note 2) 1,900 3,100 3,600 74.803 122.047 141.732 (Note 2) 2,200 3,400 3,600 86.614 133.858 141.732 (Note 2) 670 1,300 3,600 26.378 51.181 141.732 (Note 2) 1,400 2,000 3,500 55.118 78.740 137.795 (Note 2) 850 1,300 1,600 33.465 51.181 62.992 (Note 2) 1,200 1,600 1,600 47.244 62.992 (Note 2) 62.992 (Note 2) Fiber Expansion lens (Note 1) FX-LE1 Amplifier Mode FT-R40 FT-R42W FT-R43 FT-H35-M2 Fibers FT-H20W-M1 Super Quality FT-H20-M1 FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S Threaded Type Square Head Type Sleeve Flat Type Narrow Beam Wide Beam Superexpansion lens (Note 1) FX-LE2 Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Side-view lens Fiber Dimensions Thru-beam Type FX-500 series FX-100 series INDEX 3,500 137.795 2,000 78.740 1,600 62.992 500 19.685 1,000 3,500 39.370 137.795 (Note 2) Expansion lens for vacuum fiber (Note 1) Vacuumresistant side-view lens (Note 1) Amplifier Mode HYPR Fiber FT-43 3,600 FT-42 141.732 (Note 2) FT-42W 1,600 FT-45X 62.992 (Note 2) 3,600 FT-R40 141.732 (Note 2) 3,600 FT-R42W 141.732 (Note 2) 3,600 FT-R43 141.732 (Note 2) 3,600 FT-H35-M2 141.732 (Note 2) FT-H20W-M1 1,600 62.992 (Note 2) FT-H20-M1 U-LG FX-500 series LONG STD FAST H-SP FX-100 series FX-101 FX-102 3,600 3,600 3,600 3,600 3,600 3,600 3,600 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,500 137.795 (Note 2) 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,500 137.795 (Note 2) 1,600 1,600 1,600 1,600 1,600 1,600 1,600 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) FT-H13-FM2 3,600 3,600 3,600 3,600 3,600 3,600 3,500 3,500 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2) FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S 3,600 3,600 3,600 3,600 3,600 3,600 3,500 3,500 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2) FV-LE1 Semi-custom fibers Amplifiers 3,600 3,600 141.732 (Note 2) 141.732 (Note 2) Sensing range increases by 4 times or more. * Ambient temperature: -60 to +350 C -76 to +662 F (Note 4) * Beam dia: o3.6 mm o0.142 in Sensing range (mm in) [Lens on both sides] (Note 3) FX-500 series FX-100 series Amplifier Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 Fiber 3,600 3,600 3,400 1,500 900 370 450 1,600 FT-H30-M1V-S 141.732 (Note 2) 141.732 (Note 2) 133.858 59.055 35.433 14.567 17.717 62.992 Fiber Options Others 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,900 74.803 3,300 129.921 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) FX-SV1 Liquid Leak / Liquid Detection Reflective Type 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) Beam axis is bent by 90. * Ambient temperature: -60 to +300 C -76 to +572 F (Note 4) * Beam dia: o2.8 mm o0.110 in Sensing range (mm in) [Lens on both sides] FX-500 series FX-100 series Amplifier Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 Fiber 3,600 3,400 2,600 1,700 970 310 510 1,400 FT-43 141.732 (Note 2) 133.858 102.362 66.929 38.189 12.205 20.079 55.118 3,600 3,600 3,600 2,100 1,150 370 500 1,700 FT-42 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 82.677 45.276 14.567 19.685 66.929 3,600 3,500 2,700 1,800 990 320 480 1,300 FT-42W 141.732 (Note 2) 137.795 106.299 70.866 38.976 12.598 18.898 51.181 1,600 1,600 1,600 1,400 800 210 540 1,600 FT-45X 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 55.118 31.496 8.268 21.260 62.992 (Note 2) 3,600 3,500 2,700 1,800 990 320 1,400 1,000 FT-R42W 141.732 (Note 2) 137.795 106.299 70.866 38.976 12.598 55.118 39.370 3,200 1,800 1,300 950 510 160 310 930 FT-R43 125.984 70.866 51.181 37.402 20.079 6.299 12.205 36.614 3,500 1,600 1,200 780 500 150 280 800 FT-H35-M2 137.795 62.992 47.244 30.709 19.685 5.906 11.024 31.496 1,600 1,600 1,500 950 560 190 140 400 FT-H20W-M1 62.992 (Note 2) 62.992 (Note 2) 59.055 37.402 22.047 7.480 5.512 15.748 1,600 1,600 1,300 780 500 150 280 840 FT-H20-M1 62.992 (Note 2) 62.992 (Note 2) 51.181 30.709 19.685 5.906 11.024 33.071 FT-H20-J50-S 1,600 960 740 450 290 80 150 410 FT-H20-J30-S 62.992 (Note 2) 37.795 29.134 17.717 11.417 3.150 5.906 16.142 FT-H20-J20-S Vacuumresistant Retroreflective Type 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) Tremendously increases the sensing range with large diameter lenses. * Ambient temperature: -60 to +350 C -76 to +662 F (Note 4) * Beam dia: o9.8 mm o0.386 in Sensing range (mm in) [Lens on both sides] Cylindrical Type Small Spot 1,600 62.992 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 3,600 141.732 (Note 2) 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) Beam axis is bent by 90. * Ambient temperature: -60 to +300 C -76 to +572 F (Note 4) * Beam dia: o3.7 mm o0.146 in Sensing range (mm in) [Lens on both sides] (Note 3) FV-SV2 Amplifier Mode HYPR U-LG 3,600 3,600 FT-H30-M1V-S 141.732 (Note 2) 141.732 (Note 2) Fiber FX-500 series LONG STD 3,400 1,500 133.858 59.055 FAST 900 35.433 H-SP 370 14.567 FX-100 series FX-101 FX-102 450 1,600 17.717 62.992 Notes: 1) Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. 2) The fiber cable length practically limits the sensing range. 3) The fiber cable length for the FT-H30-M1V-S is 1 m 3.28 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series and in FX-102 are specified considering the length of the FT-J8 atmospheric side fiber. 4) Refer to p.12, p.15, p.30 and p.32 for the ambient temperature of fibers to be used in combination. 43 FIBER OPTIONS Refer to p.66~ for details of lens dimensions. Tough Fiber Lens (For reflective type fiber) Designation Model No. Description Pinpoint spot of o0.5 mm o0.020 in. Enables detection of minute objects or small marks. Pinpoint spot lens FX-MR1 *Distance to focal point: 6 1 mm 0.236 0.039 in *Applicable fibers: FD-42G, FD-42GW *Ambient temperature: -40 to +70 C -40 to +158 F (Note) The spot diameter is adjustable from o0.7 to o2 Sensing range for FX-500/FX-100 series mm o0.028 to o0.079 in according to how much Screw-in depth Distance to focal point Spot diameter the fiber is screwed in. *Applicable fibers: FD-42G, FD-42GW 7 mm 18.5 mm approx. o0.7 mm *Ambient temperature:-40 to +70 C 27 mm approx. o1.2 mm 12 mm -40 to +158 F (Note) Spot *Accessory: MS-EX3 (mounting bracket) 43 mm approx. o2.0 mm 14 mm diameter Screw-in depth FX-MR2 For reflective type fiber Zoom lens Finest spot lens Distance to focal point FX-MR3 Distance to focal point Spot diameter Finest spot lens FX-MR6 Extremely fine spot of o0.15 mm o0.006 in approx. achieved. *Applicable fibers: FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-32G, FD-32GX *Ambient temperature: -40 to +70 C -40 to +158 F (Note) Sensing range for FX-500/FX-100 series Extremely fine spot of o0.1 mm o0.004 in approx. achieved. *Applicable fibers: FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-32G, FD-32GX *Ambient temperature: -20 to +60 C -4 to +140 F (Note) Sensing range for FX-500/FX-100 series Screw-in FX-MR2 is converted into a side-view type and depth can be mounted in a very small space. *Applicable fibers: FD-42G, FD-42GW *Ambient temperature: -40 to +70 C -40 to +158 F (Note) Zoom lens side-view type FX-MR5 Distance to focal point Spot diameter Fiber model No. Distance to focal point Spot diameter For Square head M3 reflective fiber Lens Shape (mm in) Model No. Shape 7 0.5 0.276 0.020 o5 o0.197 15.3 0.602 FX-MR7 o0.4 o0.016 approx. Parallel light lens Zoom lens Type For Square head M3 reflective fiber Distance to focal point (mm in) o0.15 o0.006 approx. Finest spot lens Spot diameter (mm in) Sensing range (mm in) Lens Shape (mm in) o0.4 to o2.0 o0.016 to o0.079 approx. o0.4 to o2.2 o0.016 to o0.087 approx. 10 to 30 o5 o0.197 o0.5 to o2.5 o0.020 to o0.098 approx. 0.394 to1.181 o4.0 o0.157 approx. How to read Model No. Earlier models comparison table Fibers Super Quality 7.5 0.5 mm o0.15 mm approx. FD-EG30 7.5 0.5 mm o0.3 mm approx. Threaded Type FD-42G/42GW 7.5 0.5 mm o0.5 mm approx. FD-32G/32GX Square Head Type Cylindrical Type Fiber model No. Distance to focal point Spot diameter Sleeve FD-EG31 7 0.5 mm o0.1 mm approx. FD-EG30 7 0.5 mm o0.2 mm approx. Flat Type FD-42G/42GW FD-32G/32GX 7 0.5 mm o0.4 mm approx. Sensing range for FX-500/FX-100 series Screw-in depth Distance to focal point Spot diameter 8 mm 13 mm approx. o0.5 mm 10 mm 15 mm approx. o0.8 mm 14 mm 30 mm approx. o3.0 mm Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Liquid Leak / Liquid Detection Model No. o0.125 o0.005 FD-R33EG o0.125 o0.005 FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG o0.25 o0.010 FD-EG30 o0.5 o0.020 FD-R31G o0.5 o0.020 FD-32G o0.5 o0.020 FD-32GX o0.5 o0.020 FD-42G o0.5 o0.020 FD-42GW fiber Model No. Emitting core (mm in) 15 0.591 FX-MR8 10 0.394 o5 o0.197 Fiber Emitting fiber core (mm in) Applicable fibers o0.8 to o3.5 o0.031 to o0.138 approx. 0 to 30 0 to 1.181 Choose by shape/ application Heatresistant o0.1 o0.004 approx. o0.2 o0.008 approx. Model Vacuumresistant Lens (For square head M3 reflective fiber) Spot diameter (mm in) Fiber Selection Guide FD-EG31 Note: Refer to p.13 or p.23 for the ambient temperature of fibers to be used in combination. Type New product introduction FX-MR9 Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Model No. o0.125 o0.005 FD-R33EG, FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG, FD-EG30 o0.5 o0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW o0.125 o0.005 FD-R33EG, FD-EG31 o0.175 o0.007 FD-R34EG o0.25 o0.010 FD-R32EG, FD-EG30 o0.5 o0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW Amplifiers FX-500 series FX-100 series INDEX 44 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No FIBER OPTIONS Model No. when ordering heat-resistant fibers individually as replacement parts *FT-H20-J20 (one pair set) *FT-H20-J30 (one pair set) *FT-H20-VJ50 (one pair set) *FT-H20-VJ80 (one pair set) Model No. when ordering vacuum-resistant fibers individually as replacement parts *Vacuum-resistant fiber FT-H30-M1V (one pair set) FD-H30-KZ1V FD-H30-L32V Earlier models comparison table *Photo-terminal FV-BR1 (one pair set) Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX *RF-003 (FR-KZ50E/KZ50H exclusive reflector) *RF-13 (FR-Z50HW reflective tape) *FX-CT2 (Fiber cutter) *FX-CT3 (FD-H40Y/F41Y fiber cutter) *FX-AT2 (Attachment for fixed-length fiber, Orange) *FX-AT3 (Attachment for o2.2 mm o0.087 in fiber, Clear orange) *FX-AT4 (Attachment for o1 mm o0.039 in fiber, Black) *FX-AT5 (Attachment for o1.3 mm o0.051 in fiber, Gray) *FX-AT6 Attachment for o1 mm o0.039 in / o1.3 mm o0.051 in ( mixed fiber, Black / Gray *MS-FD-2 (Fiber mounting bracket) *Mouting bracket for FD-H30-KZ1V(-S) MS-FD-2 *Fiber at atmospheric side FT-J8 (one pair set) Model No. when ordering accessories additionally Fibers *FT-H20-J50 (one pair set) ) *RF-003 *RF-13 *FX-AT2 *FX-AT3 *MS-FD-2 *FX-CT2 *FX-AT4 *FX-AT5 *FX-CT3 *FX-AT6 45 FIBER OPTIONS New product introduction Others Designation Model No. FTP-1000 (1 m 3.281 ft) For M4 thread FTP-1500 (1.5 m 4.921 ft) FTP-N500 (0.5 m 1.640 ft) FTP-N1000 (1 m 3.281 ft) For M3 thread Applicable fibers Protective tube for thru-beam type fiber FTP-N1500 (1.5 m 4.921 ft) FDP-500 (0.5 m 1.640 ft) FDP-1000 (1 m 3.281 ft) Protective tube for reflective type fiber *FTP- *FDP- Description FTP-500 (0.5 m 1.640 ft) For M6 thread FDP-1500 (1.5 m 4.921 ft) FDP-N500 (0.5 m 1.640 ft) FDP-N1000 (1 m 3.281 ft) FT-42 FT-42S FT-42W FT-43 FT-H13-FM2 FT-31 FT-31S FT-31W FD-31 FD-31W Model FD-41S FD-41SW *MS-AJ1-F Universal sensor mounting stand (Note 2) MS-AJ1-F Horizontal mounting type MS-AJ2-F Vertical mounting type Single core holder Applicable fibers Fiber mounting joint (Note 2) MS-FX-02Y Mounting stand assembly for fiber (For M3, M4 or M6 threaded head fiber) This joint suppresses false operations due to liquid slip-in from the top of the protective tube. The joint is used for mounting fibers on a tank. The incident light intensity may vary when using a multi-core fiber or a thin type sharp bending fiber. This holder suppresses the variation in the incident light intensity. (Brown) FX-AT15A Used with FR-Z50HW. Refer to p.27 or p.38 for the sensing range of FR-Z50HW to be used in combination. RF-220 RF-230 Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber. 2) The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage. Liquid inflow prevention joint MS-FX-01Y *MS-FX-01Y MS-FX-01Y MS-FX-01Y Protective tube extension joint MS-FX-02Y *MS-FX-02Y MS-FX-02Y MS-FX-02Y Union nut Body Ferrule (MS-FX-YF) Body Body Union nut Ferrule (MS-FX-YF) Ferrule (MS-FX-YF) Union nut MS-FX-03Y *MS-FX-03Y MS-FX-03Y MS-FX-03Y Body Ferrule (MS-FX-YF) Body Body Union nut Ferrule (MS-FX-YF) Union nut 11 mm 360 rotation 20 20 Angle adjustment: 20 *RF-220 33.3 mm Square Head Type Cylindrical Type Flat Type Small Spot Narrow Beam Wide Beam Forward / back adjustment: 130 mm 5.118 in approx. Height adjustment: 150 mm 5.906 in approx. 20 20 Angle adjustment: 20 Mounting hole for M6 screw Single core holder Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Union nut Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Ferrule (MS-FX-YF) Union nut 8.3 mm Threaded Type Convergent Reflective Type 360 rotation Ferrule (MS-FX-YF) Union nut Union nut Ferrule Body(MS-FX-YF) Ferrule (MS-FX-YF) Body Height adjustment: 150 mm 5.906 in approx. Mounting hole for M6 screw *MS-AJ2-F *FX-AT15A Super Quality Sleeve Forward / back adjustment: 130 mm 5.118 in approx. Fiber mounting joint Ferrule (MS-FX-YF) Union nut Union nut Ferrule (MS-FX-YF) Ferrule (MS-FX-YF) Body Reflector *RF-210 360 rotation 360 rotation RF-210 Reflector The protective tube can be extended. MS-FX-03Y Fibers Using the arm which enables adjustment in the horizontal direction, sensing can also be done from above an assembly line. The fiber bender bends the sleeve part of the fiber head at the proper radius. (Note 1) FD-HF40Y FD-F41Y Earlier models comparison table Universal sensor mounting stand FB-1 Protective tube extension joint (Note 2) How to read Model No. The protective tube, made of noncorrosive stainless steel, protects the FD-62 inner fiber cable from FD-H13-FM2 any external forces. FD-61 FD-61G FD-61S FD-61W MS-FX-01Y Choose by shape/ application *FB-1 Fiber bender Liquid inflow prevention joint (Note 2) Fiber Selection Guide Fiber bender FD-41 FD-41W For M4 thread FDP-N1500 (1.5 m 4.921 ft) Union nut Tough Fiber Protective tube Others *RF-230 50.3 mm 35.3 mm 12.8 mm 8.3 mm Amplifiers FX-500 series 42.3 mm FX-100 series 59.3 mm INDEX 46 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Semi-custom fibers that flexibly meet diverse needs Guide to interchanging fiber length and sleeve length Custom-ordered products are available with different fiber lengths and sleeve lengths in order to respond quickly to different requirements. Contact us more in formation. Fiber length change Sleeve length change It is possible to extend up to 30 m 98.425 ft in units of 1 m 3.281 ft, varying depending on the model. Refer to the table on the next page for applicable models. Extension is possible up to 120 mm 4.724 in in units of 10 mm 0.394 in. Applicable models are sleeve extension-type models indicated by in the table on the next page. Fibers Fiber cable length L Super Quality Threaded Type Sleeve length Square Head Type Note that the model number differs from previous models with changed lengths. Cylindrical Type Note that the model number differs from previous models with changed lengths. Sleeve Flat Type Small Spot Narrow Beam Wide Beam *Attenuation ratio characteristics for fiber cable length and sensing range Note that the longer the fiber cable length, the shorter the sensing range. Typical example: Bending radius R4 mm/R2 mm (Tough fiber) Typical example: Bending radius R1 mm (Sharp bending fiber FT- W/FD- W) 1.0 1.0 Retroreflective Type 0.9 0.9 Chemical / Oilresistant 0.8 Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Bending radius R4 mm R0.157 in Beam axis diameter1 mm 0.039 in Sensing range coefficient Heatresistant Sensing range coefficient Convergent Reflective Type 0.7 0.6 0.5 0.4 Bending radius R2 mm R0.079 in Beam axis diameter0.5 mm 0.020 in 0.3 0.8 0.7 0.6 Bending radius R1 mm 0.0395 in Beam axis diameter1 mm 0.039 in 0.5 0.4 0.3 0.2 0.2 0.1 0.1 Bending radius R1 mm 0.0395 in Beam axis diameter0.5 mm 0.020 in 0 2 10 0 2 6.562 10 32.808 20 65.617 Fiber cable length L (m ft) 30 98.425 6.562 32.808 20 65.617 30 98.425 Fiber cable length L (m ft) Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Note: Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with varying humidity. Extended protective tube The chemical-resistant cover and stainless jacket can be extended in accordance with the fiber cable length. Applicable models are indicated in the table as follows. : Models which can have extended protective tube (fluorine resin) : Models which can have extended stainless jacket sheath Amplifiers FX-500 series FX-100 series INDEX Protective tube Fiber 47 New product introduction Tough Fiber Applicable models Thru-beam type Reflective type Applicable fiber length Basic specifications Fiber cable length : Free-cut FT-140 10 m FT-31 2m FT-31S 2m FT-31W 2m FT-42 2m FT-42S 2m FT-42W 2m FT-43 2m FT-45X 1m FT-A11 2m FT-A11W 2m FT-A32 2m FT-A32W 2m FT-AL05 2m FT-E13 1m FT-E23 1m FT-F93 2m FT-H13-FM2 2m FT-H20-J50-S 500 mm (Note 5) FT-H20-M1 1m FT-H20-VJ80-S 800 mm (Note 5) 1m FT-H20W-M1 FT-H30-M1V-S 1m 2m FT-H35-M2 FT-H35-M2S6 2m FT-HL80Y 2m (Note 6) 2m FT-KS40 FT-KV26 2m FT-KV40 2m FT-KV40W 2m FT-L80Y 2m (Note 6) FT-R31 2m 2m FT-R43 FT-R40 2m FT-R41W 2m 2m FT-R42W FT-R44Y 2m FT-R60Y 2m FT-S11 500 mm FT-S21 2m 2m FT-S21W FT-S31W 2m FT-S32 2m FT-V23 2m 2m FT-V24W FT-V25 2m 2m FT-V30 FT-V40 2m FT-V80Y 2m (Note 6) 1m FT-Z20HBW FT-Z20W 1m FT-Z30 2m FT-Z30E 2m FT-Z30EW 2m FT-Z30H 2m FT-Z30HW 2m 2m FT-Z30W FT-Z40HBW 2m FT-Z40W 2m FT-Z802Y 2m Model No. Protective tube extension length 1 m (Note 4) Sensing range (mm) FX-500 series (STD)(Note 1) 19,600 (Note 2) 315 40 (Note 3) 315 260 1,130 40 (Note 3) 1,130 800 1,400 1,200 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 860 5 15 5 75 Sleeve length (mm) 1.5 m (Note 4) 1.5 m (Note 4) 20 15 15 20 1.5 m (Note 4) 700 470 540 600 470 270 430 430 3,600 (Note 2) 3,600 (Note 2) 710 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 270 720 930 800 2,200 720 2,100 90 315 260 800 3,100 450 110 240 680 3,500 3,600 (Note 2) 260 620 2,100 3,500 3,400 3,500 3,500 1,500 800 1,500 3,100 Max. Unit (m) (m) 30 30 30 20 30 30 30 30 10 10 10 10 10 20 10 10 30 30 6.5 6.5 6.5 6.5 6.5 6.5 6.5 30 10 10 10 10 30 30 30 30 30 30 30 30 30 30 20 30 30 30 10 30 30 30 30 20 20 30 30 20 30 20 20 20 20 30 1 1 1 1 1 1 1 1 0.5 1 1 1 1 1 0.5 0.5 1 1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Retroreflective type Applicable fiber length Basic specifications Model No. FR-KZ22E FR-KZ50E FR-KZ50H FR-Z50HW Fiber cable length : Free-cut 2m 2m 2m 2m Protective tube extension length Sleeve length (mm) Sensing range (mm) FX-500 series (STD)(Note 1) 15 to 310 20 to 300 20 to 300 100 to 990 Max. Unit (m) (m) 10 10 10 30 1 1 1 1 Applicable fiber length Basic specifications Fiber cable length : Free-cut FD-31 2m FD-31W 2m 2m FD-32G FD-32GX 1m 2m FD-41 FD-41S 2m FD-41SW 2m 2m FD-41W 2m FD-42G FD-42GW 2m FD-61 2m FD-61G 2m FD-61S 2m 2m FD-61W FD-62 2m 1m FD-64X FD-A16 2m 2m FD-AL11 FD-E13 1m FD-E23 1m FD-EG30 500 mm FD-EG30S 1m FD-EG31 500 mm FD-F4 2m FD-F41 2m FD-F71 5m 2m FD-FA93 FD-H13-FM2 2m FD-H18-L31 2m FD-H20-21 1m FD-H20-M1 1m FD-H25-L43 3m FD-H25-L45 3m FD-H30-KZ1V-S 1m FD-H30-L32 2m FD-H30-L32V-S 3m FD-H35-20S 1m FD-H35-M2 2m FD-H35-M2S6 2m FD-L10 2m FD-L11 2m FD-L12W 1m FD-L20H 2m FD-L21 2m FD-L21W 2m FD-L22A 2m FD-L23 3m FD-L30A 3m FD-L31A 3m FD-L32H 4m FD-R31G 2m FD-R32EG 500 mm 500 mm FD-R33EG FD-R34EG 500 mm FD-R41 2m FD-R60 2m FD-R61Y 2m FD-S21 1m FD-S31 2m FD-S32 2m FD-S32W 2m FD-S33GW 2m FD-S60Y 2m (Note 6) FD-V30 2m 2m FD-V30W 2m FD-V50 FD-Z20HBW 1m FD-Z20W 1m FD-Z40HBW 2m FD-Z40W 2m FD-Z50HW 2m Model No. Protective tube extension length Sensing range Max. Unit (mm) FX-500 series (m) (m) (STD)(Note 1) 125 30 1 80 20 1 200 30 1 300 mm (Note 4) 200 30 1 125 30 1 40 (Note 3) 125 30 1 40 (Note 3) 80 20 1 270 20 1 200 30 1 150 20 1 450 30 1 420 30 1 40 (Note 3) 420 30 1 270 30 1 520 30 1 280 10 0.5 200 30 1 320 20 1 3 12 3 0.1 5 55 3 0.1 48 3 0.1 15 50 3 0.1 20 3 0.1 10 1 10 1 3 m (Note 4) 20 1 10 1 350 30 1 16 5 1 230 6.5 0.1 330 6.5 0.1 1.5 to 26 6.5 0.1 5 to 42 6.5 0.1 20 to 200 6.5 0.1 17 5 1 8 6.5 0.1 260 6.5 0.1 260 6.5 0.1 260 6.5 0.1 0 to 5 5 1 0 to 9.5 5 1 8 5 1 30 5 1 1.5 to 16 5 1 3 to 14 5 1 0 to 24 5 1 0 to 29 5 1 0 to 43 5 1 4 to 33 5 1 0 to 56 5 1 170 30 1 45 3 0.1 19 3 0.1 38 3 0.1 210 30 1 290 30 1 280 30 1 80 20 1 125 30 1 420 30 1 270 20 1 150 20 1 1.5 m (Note 4) 320 30 1 15 65 30 1 15 20 10 1 20 120 30 1 2 to 85 20 1 1 to 65 20 1 260 20 1 190 20 1 10 to 650 30 1 Sleeve length (mm) : Models which can have extended sleeve : Models which can have extended protective tube (fluorine resin) : Models which can have extended stainless jacket sheath Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range. 3) Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in. 4) Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft. (however, FD-32GX is in units of 0.1 m 0.328 ft.) 5) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut). 6) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted. Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 48 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application DIMENSIONS (Unit: mm in) Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-140 Free-cut o23 o0.906 19 0.748 o10 o0.394 o10 o0.394 Lens (PMMA) 17 23 0.906 0.669 8 8 3.5 0.315 0.315 0.138 Holder (ABS) Toothed lock washer M14 [Iron (Chromed)] Free-cut 2 0.079 o6.5 o0.256 10 0.394 Narrow Beam Wide Beam Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options o1 o0.039 Retroreflective Type Reflective Type (o2) (o0.079) Model No. tube (m-PPE) o6.5 o0.256 2.7 0.106 10 0.394 2 5.5 0.079 0.217 2,000 78.740 1.8 0.071 (30)(1.181) Hexagon nut M3 [Stainless steel(SUS304)] 1.8 0.071 (30) (1.181) FT-42 Free-cut FT-140 3 0.118 1 0.039 o2 3.5 0.138 o0.079 o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Hexagon nut M3 [Stainless steel (SUS304)] M3 x 0.5 0.020 FT-40 o8.5 o0.335 3.5 0.138 3 0.118 2.4 0.094 o2 o0.079 2,000 78.740 Resin plug (ABS) (o4.33) (20) o2.2 (o0.170) (0.787) o0.087 12 0.472 1 0.039 o4 o0.157 -0.10 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Brass (Nickel plated)] FT-31S (19.7) (0.776) 10.2 0.402 (0.3) (0.012) o2.2 o1.8 (o3.2) (o0.126) Model No. tube (m-PPE) o0.087 o0.071 Toothed lock washer M4 [Brass (Nickel plated)] Opposing faces 7 0.276 thickness 2.4 0.094 [Brass (Nickel plated)] M4 x 0.7 0.028 FT-42S Free-cut 12 0.472 2.4 0.094 2,000 78.740 o2.2 o0.087 (30) (1.181) o1 o0.039 fiber core x 1 (Acrylic) Sheath o2.2 o0.087 (Polyethylene) o4 o0.157 -0.1 0.004 -0.13 0.005 Mounting reference surface (Screw periphery) End bracket [Stainless steel(SUS303)] (o3.2) (o0.126) Model No. tube (m-PPE) Toothed lock washer M4 [Stainless steel(SUS304)] Opposing faces 7 0.276 thickness 2.4 0.094 [Stainless steel(SUS304)] M2.6 x 0.45 0.018 M4 x 0.7 0.028 FT-42W Free-cut o8.5 o0.335 7 0.276 3.5 0.138 12 0.472 40 1.575 Allowable 10 bending 10 0.394 range 0.394 5 0.197 2,000 78.740 2.4 0.094 o2.5 o0.098 o1.48 o0.058 Sleeve [Stainless steel (SUS304)] M4 x 0.7 0.028 Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] (30) (1.181) 12 0.472 2,000 78.740 2.4 0.094 (30) (1.181) o2.2 o0.087 o2 -0.1 -0.004 o4 o0.157 -0.13 -0.005 o0.079 Mounting reference surface (Screw periphery) M2.6 x 0.45FT-31W 0.018 M4 x 0.75 0.030 Toothed lock washer M4 [Stainless steel (SUS304)] (o3.2)(o0.126) Model No. tube (m-PPE) o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] Hexagon nut M4 [Stainless steel (SUS304)] o2.2 o0.087 (o3.2)(o0.126) Model No. tube (m-PPE) o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] FT-43 Free-cut 3 7 0.276 0.118 3.5 0.138 1 0.039 o1 o0.039 (o2)(o0.079) Model No. tube (m-PPE) o2 o0.079 M2.6 x 0.45 0.018 Amplifiers INDEX 2,000 78.740 End bracket [Stainless steel (SUS303)] o1 o0.039 (o2)(o0.079)Model No. tube(m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel(SUS303)] -0.1 -0.004 o3 o0.118 -0.13 -0.005 Mounting reference surface (Screw periphery) o2 o0.079 M3 x 0.5 0.020 Toothed lock washer M3 [Stainless steel(SUS304)] o8.5 o0.335 FX-100 series 5 0.197 Toothed lock washer M3 [Stainless steel (SUS304)] Opposing faces 5.5 0.217 thickness 1.8 0.071 [Stainless steel (SUS304)] Free-cut Allowable 10 bending 10 0.394 range 0.394 o0.88 o0.035 Sleeve [Stainless steel (SUS304)] Toothed lock washer M3 [Stainless steel (SUS304)] Others FX-500 series 2.7 0.106 10 0.394 40 1.575 5.5 0.217 Semi-custom fibers Thru-beam Type Free-cut o6.5 o0.256 FT-31W o8.5 o0.335 Fiber Dimensions Opposing faces 5.5 0.217 thickness 1.8 0.071 [Brass (Nickel plated)] FT-31S o0.5 o0.020 fiber core x 1 (Acrylic) Sheath o1 o0.039 (Polyethylene) o3 o0.118 -0.10 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Stainless steel (SUS303)] M3 x 0.5 0.020 Convergent Reflective Type Retroreflective Type 0.402 (0.3) (0.012) o2.2 o1.8 (o2) (o0.079) Model No. tube (m-PPE) o0.087 o0.071 Toothed lock washer M3 [Brass (Nickel plated)] o3 o0.118 -0.10 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Brass (Nickel plated)] 2,000 78.740 1.8 0.071 (30) (1.181) Sleeve Small Spot (19.7) (0.776) 10.2 o2 o0.079 2.7 0.106 2,000 78.740 1.8 Resin plug(ABS) 0.071 o1 (o4.33)(o0.170) (20) (0.787) o0.039 10 0.394 M3 x 0.5 0.020 FT-31 Cylindrical Type Flat Type o2.2 o0.087 (30) (1.181) Hexagon nut M14 [Brass (Nickel plated)] Threaded Type Square Head Type 2 o6.5 o0.256 0.079 2.7 0.106 o2 o0.079 10,000 393.701 (o3.2)(o0.126) Model No. tube (m-PPE) o4.5 o0.177 o1 o0.039 fiber core x 1 (PMMA) o7 o0.276 Sheath o2.2 o0.087 (Polyethylene) Protector (PVC) M14 x 1 0.039 Fibers Super Quality FT-30 How to read Model No Earlier models comparison table Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. o8.5 o0.335 7 0.276 3.5 0.138 3 0.118 1 0.039 2,000 78.740 12 0.472 o2 -0.1 -0.004 o4 o0.157 -0.13 -0.005 o0.079 Mounting reference surface (Screw periphery) M4 x M2.6 x 0.45 0.018 0.7 0.028 Toothed lock washer M4 [Stainless steel (SUS304)] 2.4 0.094 (30) (1.181) o2.2 o0.087 (o3.2)(o0.126) Model No. tube (m-PPE) o1.5 o0.059 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] Hexagon nut M4 [Stainless steel (SUS304)] 49 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-45X FT-A11 4.2 0.165 (13.5) 9.5 0.374 (0.531) FT-A11W Free-cut Lens (Norbornene resin) Sensing face (2.2 x 11) (0.087 x 0.433) 57 FT-A32 Free-cut Center of beam axis 27 1.063 Beam axis (8)(0.315) 2,000 78.740 4 0.157 5.2 0.205 o1.3 o0.051 (13.5) 9.5 (0.531) 0.374 4R 0.1 57 o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 2-o3.2 o0.126 o6.0 o0.236 countersinking (on both sides) Enclosure (PC) 4 19 0.748 0.157 2-R 5 0.197 16 (20) 0.630 (0.787) 4 FT-A32W Free-cut 12 0.472 2-o3.2 o0.126 o6 o0.236 countersinking (on both sides) 45 1.772 FT-AL05 Free-cut FT-45X Center of beam axis 19 0.748 5 0.197 Sensing face (3.2 x 32) (0.126 x 1.260) Lens (Norbornene resin) 4 0.157 65 2.559 2,000 78.740 Beam Enclosure (PC) 5.2 axis 0.205 o1.3 o0.051 7.3 0.287 (19) (0.748) 16 (20) 0.630 (0.787) .157 12 0.472 FT-E13 Free-cut 1,000 39.370 15 0.591 2-M3 x 0.5 0.020 15 10 0.394 0.591 FT-E23 Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Free-cut Fiber Options 15 0.591 50.5 0.1970.020 (o2) (o0.079) Model No. tube (m-PPE) End bracket [Stainless steel (SUS303)] 1,000 39.370 (30) (1.181) o1 o0.039 o0.25 o0.010 fiber core x1 (PMMA) Semi-custom fibers Free-cut Beam-emitting side (Gray) 3 0.118 7.2 0.283 6 0.236 Enclosure (ABS) 6 0.236 Beam-receiving side (Black) o0.25 o0.010 x 4fiber core (PMMA) Sheath o1 o0.039 (Polyethylene) o3.1 o0.122 Protective tube [PFA(Fluorine resin)] o3.1 o0.122 o1.5 o0.059 fiber core x 1 Retroreflective Type Free-cut 3.5 0.138 Thru-beam Type Others FT-H13-FM2 2,000 78.740 2-o1 o0.039 Fiber Dimensions Reflective Type 0 0 o0.4 o0.016 -0.1 -0.004 FT-F93 1,000 39.370 o0.5 o0.020 x 1 fiber core (PMMA) Sheath o1 o0.039 (Polyethylene) 0 0 Details of (o2) (o0.079) Model No. tube (m-PPE) o3 o0.118 -0.1 -0.004 sensing part Mounting reference surface (Periphery) o0.25 o0.010 0 0 -0.1 -0.004 FT-A32W 17 9 0.354 0.669 Square Head Type FT-A11 Sensing part (o0.25 fiber core o0.010 x 16) o0.125 o0.005 fiber core x 1 (PMMA) 5.5 0.217 Threaded Type Sleeve [StainlessFT-A32 steel (SUS304)] Details of o3 o0.118 0 0 -0.1 -0.004 sensing part Mounting reference surface (Periphery) 10.3 0.406 Super Quality Liquid Leak / Liquid Detection o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] 23 0.906 o0.25 o0.010 fiber core x 16 (PMMA) Sheath o2.2 o0.087 (Polyethylene) 5.25 0.207 Sleeve [Stainless steel (SUS304)] 20 0.787 12 0.472 o2.2 o0.087 4.5 0.177 Enclosure (PPS) o1 (30) o0.039 (1.181) 50.5 0.1970.020 Earlier models comparison table Retroreflective Type 2.5 0.098 2.5 0.098 4.5 Details of 0.177 sensing part 1 0.039 2-o3.2 o0.126 o6 o0.236 countersinking (on both sides) 45 1.772 FT-A11W 2,000 78.740 15 0.591 8 0.315 5 0.197 Head block (LCP) o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 4 R0 157 R0. o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Sensing face (3.2 x 32)(0.126 x 1.260) Lens (Norbornene resin) 4 0.157 65 2.559 2,000 78.740 Beam axis Enclosure (PC) 5.2 0.205 o1.3 o0.051 7.3 0.287 (19) (0.748) 2-R 2-R Center of beam axis 19 0.748 4 0.157 4.2 0.165 How to read Model No. Fibers 8 0.315 Choose by shape/ application o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 2-o3.2 o0.126 o6.0 o0.236 countersinking (on both sides) Enclosure (PC) 19 4 0.157 0.748 Fiber Selection Guide Model 4 0.157 27 1.063 2,000 78.740 Beam axis 4 0.157 o1.3 5.2 0.205 o0.051 (8) (0.315) 2R4 o2.2 o0.087 (o4)(o0.157) Model No. tube (m-PPE) Resin plug (ABS) Protective tube Polyolefin tube included SUS304 spiral tube Crimping part Lens (Norbornene resin) Sensing face (2.2 x 11) (0.087 x 0.433) 8 0.315 .1 o2 o0.079 M4 x 0.7 0.028 Toothed lock washer M4 Details of sensing part [Stainless steel (SUS304)] 3.5 0.138 Hexagon nut M4 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] o1 o0.039 fiber core x 1 (PMMA) o8.5 o0.335 Center of beam axis R0 3 0.118 1 0.039 2.4 0.094 M2.6 x 0.45 0.018 7 0.276 1,000 39.370 19.7 0.776 (2.5)(0.098) o2.6 o0.102 (o4.33)(o0.170) (30) 10.2 (1.181) 0.402 Tough Fiber Free-cut 20 0.787 12 0.472 New product introduction 13 0.512 12 0.472 o3 o0.118 M4 x 0.7 0.028 Screw tightening face 2,000 78.740 Amplifiers FX-500 series FX-100 series o2.2 o0.087 (Fluorine resin) Opposing faces 7 0.276, thickness 2.4 0.094 Toothed lock washer o8.5 o0.335 INDEX 50 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-H20-J20-SFT-H20-J30-SFT-H20-J50-S Free-cut (Note) Heat-resistant side unit diagram (side view) 3 0.118 2.5 0.098 M2.6 x 0.45 0.018 M4 x 0.7 0.028 End bracket [Brass (nickel plated)] B (25.8) (1.016) 17 0.669 6 0.236 Threaded Type 30 1.181 o2.2 o0.087 (o3.2) (o0.126) Model No. tube (m-PPE) M4 x 0.7 0.028 Opposing faces 7 0.276, o1 o0.039 fiber core x 1 (Acrylic) thickness 3.2 0.126 Outer sheath o2.2 o0.087 (Polyethylene) (Polypropylene) Sleeve Model No. A B 185 +30 0 Small Spot FT-H20-J20-S 200 +25 0 Narrow Beam FT-H20-J30-S 300 +25 11.811 +0.984 0 0 285 +30 11.221 +1.181 0 0 FT-H20-J50-S 500 +25 19.685 +0.984 0 0 +1.181 485 +30 0 19.095 0 Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series 7.284 +1.181 0 Note: Ordinary temperature side fiber (FT-42) only. FT-H20-M1 20 0.787 3 0.118 3.5 0.138 9.3 0.366 o3.5 o0.138 5.4 0.213 Lock nut (polycarbonate) Ordinary temperature side fiber (FT-42) connection diagram (front view) 8 0.315 2.2 0.087 2,000 78.740 (25.8) (1.016) 30 17 1.181 0.669 6 0.236 M4 x 0.7 0.028 B 24 0.945 12 0.472 Set screw tightening range o2.2 o0.087 Head [Brass (Nickel plated)] (o3.2) (o0.126) Model No. tube (m-PPE) Spring washer [Stainless steel (SUS)] Opposing faces 7 0.276, o1 o0.039 fiber core x 1 (Acrylic) thickness 3.2 0.126 Holder Outer sheath o2.2 o0.087 (Polyethylene) (Polypropylene) [Brass (Nickel plated)] Prism (BK7) Model No. A B FT-H20-VJ50-S 500 +25 19.685 +0.984 0 0 +1.969 800 +50 31.496 0 0 485 +30 19.095 +1.181 0 0 +55 785 0 30.906 +2.165 0 FT-H20-VJ80-S Note: Ordinary temperature side fiber (FT-42) only. 1,000 39.370 Heat & cold-resistant Ordinary temperature specifications specifications 150 5.906 12 0.472 16.7 0.657 o5 o0.197 Fixing bracket [Brass (nickel plated)] Screw tightening face M2.6 x 0.45 0.018 M4 x 0.7 0.028 3 0.118 18.3 0.720 3.5 0.138 Fixing plug (PA) Opposing faces 7 0.276, thickness 2.4 0.094 Toothed lock washer o8.5 o0.335 FT-H30-M1V-S o4 o0.157 30 1.181 11 0.433 o1.6 o0.063 150 5.906 19.5 0.768 10 0.394 o2.2 o0.087 o4.33 o0.170 (PA) Protective tube (PTFE) Opposing faces 7 0.276, thickness 2.4 0.094 Toothed lock washer o8.5 o0.335 o3.6 o0.142 Mounting cap nut opposing faces 8 0.315 [Stainless steel (SUS)] Joint [Stainless steel (SUS)] Liner+braid tube [Stainless steel (SUS)] FT-H35-M2S6 2,000 78.740 Heat & cold-resistant Ordinary temperature specifications specifications 17 0.669 o4 o0.157 M2.6 x 0.45 0.018 M4 x 0.7 0.028 o1.2 o0.047 fiber core bundle x 1 Note: The FT-H30-M1V-S is a set with the FT-H30-M1V, photo-terminal, and atmospheric side fiber. Refer to p.66 for dimensions of the atmospheric side fiber and photo-terminals. 150 5.906 27 1.063 17 0.669 2,000 78.740 16.7 0.657 18.3 0.720 o2.2 o5 o0.197 Fixing bracket o0.087 [Brass (nickel plated)] o2.9 o0.114 [Stainless steel (SUS)] Fixing plug (PA) o4 o0.157 [Stainless steel (SUS)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)] Toothed lock washer o8.5 o0.335 [Stainless steel (SUS)] 18.3 0.720 Free-cut Heat & cold-resistant Ordinary temperature specifications specifications 150 5.906 16.7 0.657 o2.2 o2.9 o0.114 o0.087 [Stainless steel (SUS)] Fixing plug (PA) o4 o0.157 [Stainless steel (SUS)] o5 o0.197 Fixing bracket [Brass (Nickel plated)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)] Toothed lock washer o8.5 o0.335 [Stainless steel (SUS)] FT-HL80Y 60 2.362 M4 x 0.7 0.028 [Stainless steel (SUS)] 27 1.063 4 0.157 End bracket [Stainless steel (SUS)] Toothed lock washer o7.6 o0.299 [Stainless steel (SUS)] o2.1 o0.083 [Stainless steel (SUS)] M4 x 0.7 0.028 3 0.118 1,000 39.370 Opposing faces 7 0.276, thickness 3.2 0.126 [Stainless steel (SUS)] o1.2 o0.047 fiber 5 core bundle x 1 0.197 Heat & cold-resistant Ordinary temperature specifications specifications o2.5 o0.098 M2.6 x 0.45 0.018 o0.8 o0.031 fiber core bundle x 1 1,000 39.370 FT-H35-M2 30 1.181 17 0.669 M2.6 x 0.45 0.018 M4 x 0.7 0.028 Screw tightening face 20 0.787 o2.2 o0.087 o2.9 o0.114 (Silicone) o4 o0.157 [Brass (Nickel plated)] o1.1 o0.043 fiber core bundle x 1 3 0.118 2.5 0.098 o2.7 o0.106 Liner + braid tube [stainless steel (SUS304)] Joint bracket [Brass (nickel plated)] FT-H20W-M1 o3 o0.118 [Stainless steel (SUS)] INDEX 7.874 +0.984 0 (100) (3.937) o3.8 o0.150 2,000 78.740 Spring washer [Stainless steel (SUS)] Cylindrical Type Heat-resistant side unit diagram (side view) Beam axis o4 o0.157 Opposing faces7 0.276, 5.4 o3.5 o0.138 thickness 2.4 0.094 0.213 Lock nut (polycarbonate) Toothed lock washer o2.7 o0.106 Liner + braid tube [Stainless steel (SUS)] o8.5 o0.335 Free-cut (Note) 24 A 0.945 Heat & cold-resistant Ordinary temperature specifications specifications Ordinary temperature side fiber (FT-42) connection diagram (front view) Square Head Type FT-H20-VJ50-SFT-H20-VJ80-S 23 0.906 A 12 Joint bracket 0.472 [Brass (nickel plated)] Heat & cold-resistant Ordinary temperature specifications specifications 9.3 o4 o0.157 (100) (3.937) 0.366 Super Quality Flat Type Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) (25) (0.984) o5.5 o0.217 1,500 59.055 2,000 78.740 500 19.685 (Allowable cutting range) o2.2 o0.087 (o4) (o0.157) protective tube (Fluorine resin) 51 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-KS40 Free-cut FT-KV26 2,000 78.740 (Set screw tightening range) (30) o1 o0.039 (1.181) 8 0.315 Beam axis (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) o3.5 o0.138 o3.7 o0.146 Holder (PC) End bracket [Stainless steel (SUS303)] Free-cut o o0 4 .15 7 o2.5 o0.098 Holder (PC) Assembly dimensions with MS-FD-3 (attached mounting bracket) 3 0.118 3.2 0.126 3.2 0.126 (30) 3.3 (1.181) 0.130 3.3 0.130 FT-KS40 R0. 2.5 2-R C1 C0.039 Enclosure (LCP) 5 0.197 5 0.197 o1 o0.039 (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Free-cut 2,000 78.740 1,500 59.055 (25) (0.984) 500 19.685 (Allowable cutting range) FT-R31 2,000 78.740 1.7 0.067 Enclosure [ZDC2 (Nickel plated)] 11.3 0.445 Toothed lock washer M3 [Stainless steel (SUS304)] Hexagon nut M3 [Stainless steel (SUS304)] 1.8 0.071 o2.3 o0.091 (o2) (o0.079) Model No. tube (m-PPE) 3.8 0.150 (30) (1.181) o6.5 5.5 o0.256 0.217 o1 o0.039 FT-R40 Free-cut Super Quality Threaded Type Square Head Type Flat Type Small Spot Sheath o1 o0.039 (Polyethylene) FT-R41W Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant FT-KV25 2.1 0.083 Fibers Wide Beam 3.5 0.138 M3 x 0.5 0.020 Earlier models comparison table Narrow Beam Cap [Stainless steel (SUS304-CSP)] 8 0.315 How to read Model No. Sleeve Free-cut Complete thread 10.8 0.425 or more 5.5 0.217 3.7 0.146 Choose by shape/ application Cylindrical Type o2.2 o0.087 (o4) (o0.157) protective tube (Fluorine resin) o5.5 o0.217 12.5 0.492 098 Mounting bracket [Stainless steel (SUS304)] o1 o0.039 (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) R 6.5 0.256 4.7 0.185 o2.5 o0.098 6.5 0.256 Holder (PC) 4.1 0.161 2,000 78.740 25 0.984 10 0.394 (30) (1.181) FT-L80Y (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Enclosure (LCP) 2,000 78.740 End bracket [Stainless steel (SUS303)] 2 0.079 o1 o0.039 (30) (1.181) 3 0.118 Prism (PC) 4-C0.15 C0.006 2,000 78.740 25 0.984 Prism (PC) (0.5) (0.020) Prism (PC) Fiber Selection Guide Model Mounting reference surface 20 0.787 18 0.709 39 o1 0.0 o Beam axis 1.7 0.067 FT-KV40, FT-KV40W 3.7 0.146 1.5 1.3 0.059 0.051 Tough Fiber Free-cut 20 0.787 New product introduction Free-cut Vacuumresistant Liquid Leak / Liquid Detection 2,000 78.740 o1.2 o0.047 Stainless pipe [Stainless steel (SUS304)] 2.4 0.094 25 0.984 20 0.787 o2.7 o0.106 (30) (1.181) 5 90 97 .1 9 R0 .03 R5 1 0 1 0.039 3 0.118 9 0.354 Enclosure [Zinc die-cast (ZDC2)] 7 0.276 5 0.197 12 0.472 o2.2 o0.087 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) (o3.2) (o0.126) Model No. tube (m-PPE) Fixing bracket [Stainless steel (SUS303)] Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] o2 o0.079 -0.004 o4 o0.157 -0.1 -0.13 -0.005 Mounting reference surface (Screw periphery) 4.4 0.173 1 0.039 9.5 0.374 8 0.315 2.4 0.094 M4 x 0.7 0.028 7 0.276 o8.5 o0.335 3.2 0.126 Fiber Options 2,000 78.740 6 0.236 (30) (1.181) (o3.2) (o0.126) Model No. tube (m-PPE) Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] o2.2 o0.087 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) M4 x 0.7 0.028 Retroreflective Type 7 0.276 Reflective Type 3.2 0.126 FT-R42W Free-cut FT-R43 Free-cut 8 0.315 2.4 0.094 M4 x 0.7 0.028 Enclosure FT-KV40W [Zinc die-cast (ZDC2)] 6 0.236 4.4 0.173 1 0.039 10 0.394 0.5 0.020 Lens (PMMA) o8.5 o0.335 3.2 0.126 9 0.354 Complete thread 6.5 0.256 or more 7 0.276 5.2 0.205 2.4 0.094 3.5 0.138 2,000 78.740 (30) (1.181) Cap [Stainless steel (SUS304-CSP)] 9 0.354 2 0.079 2,000 78.740 (o3.2) (o0.126) Model No. tube (m-PPE) 7 0.276 o2.2 o0.087 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) Enclosure [ZDC2 (Nickel plated)] M4 x 0.7 0.028 3 0.118 M2.6 x 0.45 0.018 o8.5 o0.335 Toothed lock washer M4 [Stainless steel (SUS304)] 1 0.039 o2 o0.079 1.8 0.1 0.071 0.004 Amplifiers (30) (1.181) 7 0.276 (o3.2) (o0.126) Model No. tube (m-PPE) Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] Others 7 0.276 Fiber Dimensions Thru-beam Type M2.6 x 0.45 0.018 o8.5 o0.335 Semi-custom fibers FX-500 series FX-100 series Hexagon nut M4 [Stainless steel (SUS304)] FT-R41W 4.2 0.165 o2.2 o0.087 INDEX 7 0.276 3 0.118 o1 o0.039 fiber core x 1 (Acrylic) Sheath o2.2 o0.087 (Polyethylene) 52 New product introduction Tough Fiber Fiber Selection Guide Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-R44Y Free-cut FT-R60Y Free-cut Model Choose by shape/ application How to read Model No Earlier models comparison table Cap [stainless steel (SUS304-CSP)] 6 mm 0.236 in or more (complete thread) 9.5 0.374 3.5 0.138 7 0.276 Toothed lock washer M4 [stainless steel (SUS304)] 3 0.118 Fibers M4 x 0.7 0.028 M2.6 x 0.45 0.018 7 o8.5 o0.335 0.276 Sleeve Flat Type Wide Beam Chemical / Oilresistant 3 Set screw tightening range 0.118 19.5 0.768 (30) (1.181) Resin plug (PA) (o1.5) (o0.059) Model No. tube (m-PPE) FT-S21 Free-cut o1 o0.039 (19.7) (0.776) 10.2 0.402 (0.3) (0.012) o1 (o4.33)(o0.170) o2.2 o1.8 o0.039 o0.087 o0.071 (o2) (o0.079) Model No. tube (m-PPE) o1.5 o0.059 -0.07 -0.003 -0.10 -0.004 Mounting reference surface (Periphery) End bracket [Stainless steel (SUS303)] FT-S21W Free-cut 2 0.079 8 0.315 8 0.315 2 0.079 2,000 78.740 3 0.118 (Set screw tightening range) o1 o0.039 (30) 3 0.118 2,000 78.740 (Set screw tightening range) (30) (1.181) o1 o0.039 (1.181) o1 o0.039 (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 Fiber core x 1 (Acrylic) Sheath o1.0 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] -0.003 o1.5 o0.059 -0.07 -0.1 -0.004 Mounting reference surface (Screw periphery) FT-S31W FT-S30 Free-cut 2 0.079 Set screw 5 tightening range 0.197 8 0.315 o2 o0.079 Thru-beam Type Reflective Type 2,000 78.740 Resin plug (ABS) (20) (0.787) o1.5 o0.591 -0.07 -0.003 -0.1 -0.004 Mounting reference surface (Periphery) Retroreflective Type 8 0.315 o1 o0.039 o2.2 o0.087 (o4.33) (o0.170) o1 o0.039 Liquid Leak / Liquid Detection Fiber Dimensions 2 0.079 Set screw 3 tightening range 0.118 10 0.394 End bracket [Stainless steel(SUS303)] o0.25 o0.010 fiber core x 1 (PMMA) Sheath o0.7 o0.028 (Polyethylene) Vacuumresistant Semi-custom fibers o11 o0.433 10 0.394 500 19.685 6 0.236 Heatresistant Fiber Options Hexagon nut M6 [stainless steel (SUS304)] Cover [PFA (Fluorine resin)] Convergent Reflective Type Retroreflective Type M6 x P0.75 FT-S20 FT-S11 Small Spot Narrow Beam Hexagon nut M4 [stainless steel (SUS304)] o1.0 o0.039 fiber core x 1 (PMMA) Outer sheath o2.2 o0.087 [PFA (Fluorine resin)] Inner sheath o1.8 o0.071 (Polyethylene) Threaded Type Cylindrical Type o2.2 o0.087 Head [stainless steel (SUS304)] Toothed lock washer M6 [stainless steel (SUS304)] 14 0.551 (1.7 0.067) Super Quality Square Head Type 2,000 78.740 5.5 0.217 o2.2 o0.087 Head [stainless steel (SUS304)] 7 0.276 1 0.039 1.80.1 0.0710.004 o2 o0.079 Cap [stainless steel (SUS304-CSP)] 11 0.433 5 0.197 10 0.394 5.5 0.217 2.4 0.094 12.5 mm 0.492 in or more (complete thread) 2,000 78.740 2,000 78.740 Resin plug (ABS) (20) (0.787) 2 0.079 (19.7) (0.776) 10.2 0.402 (0.3) (0.012) (o4.33)(o0.170) o2.2 o1.8 o2.2 o0.087 o0.087 o0.071 (o3.2) (o0.126) Model No. tube (m-PPE) o3 o0.118 -0.07 -0.003 -0.10 -0.004 Mounting reference surface (Periphery) End bracket [Stainless steel (SUS303)] 8 2,000 78.740 0.315 (Set screw tightening range) 5 o2.2 o0.087 0.197 (30)(1.181) (o3.2) (o0.126) Model No. tube (m-PPE) -0.003 o3 o0.118 -0.07 -0.1 -0.004 Mounting reference surface (Periphery) o2 o0.079 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] Others FT-S32 Free-cut FT-V23 Free-cut FX-500 series FX-100 series INDEX FT-S11 Screw tightening range (excluding crimping part) o2 o0.079 Lens (PMMA) o2.5 o0.098 End bracket [Stainless steel (SUS303)] Crimping part 8 0.315 1.8 0.071 2,000 78.740 2 0.079 (30) (1.181) o2.2 o0.087 (o3.2)(o0.126) Model No. tube (m-PPE) o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) View A 1.1 0.043 o o0 0.8 .0 31 Amplifiers 10 0.394 Set screw tightening range Beam axis 20 0.787 o1 o0.039 A 15 0.591 o2 o0.079 Sleeve [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] 2,000 78.740 (30) o1.3 o0.051 (1.181) (o2.5) (o0.098) Model No. tube (m-PPE) o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 53 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-V24W Free-cut FT-V25 Set screw tightening range 10 0.394 1.8 0.071 1 0.039 2 0.02 55 o o0. 10 0.394 1.8 0.071 1 0.039 (30) (1.181) o2 o0.079 15 0.591 o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) o1 o0.039 Sleeve [Stainless steel (SUS304)] Fiber Selection Guide Model 2,000 78.740 (30) o1 o0.039 (1.181) 15 0.591 o2 o0.079 A o1 o0.039 (o2) (o0.079) Model No. tube (m-PPE) Sleeve [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] Set screw tightening range Beam axis o o0 0.5 .0 5 22 2,000 78.740 15 0.591 15 0.591 o1 A o0.039 View A Beam axis Tough Fiber Free-cut View A New product introduction (o2) (o0.079) Model No. tube (m-PPE) Choose by shape/ application How to read Model No. Earlier models comparison table o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] Fibers FT-V30 Free-cut FT-V40 Free-cut 10 Set screw tightening range 0.394 2.3 0.091 43 .0 .1 o0 57 View A o o0 4 .1 1.3 0.051 2,000 78.740 15 0.591 20 0.787 FT-V24W o1.5 o0.059 A (30) (1.181) o2.5 o0.098 End bracket [Stainless steel (SUS303)] Prism (PC) o2.2 o0.087 (o3.2) (o0.126) Model No. tube(m-PPE) Sleeve [Stainless steel (SUS304)] o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) FT-V80Y 25 0.984 3.7 0.146 3 0.118 (8) (0.315) Beam axis o1 Free-cut 12 0.472 o2.5 o0.098 FT-V25 2,000 78.740 (Set screw tightening range) (30) (1.181) (o3.2) (o0.126) Model No. tube (m-PPE) o0.75 o0.030 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] Window name plate (Polyester) Holder (PC) 1,500 59.055 (25) (0.984) 4.5 0.177 500 19.685 (Allowable cutting range) FT-Z20HBW Free-cut 2 0.079 1.05 0.041 o5.5 o0.217 Sensing part Beam axis mark o1.5 o0.059 (30) (1.181) Beam axis FT-Z20W Free-cut 0.5 0.020 5 0.197 10 0.394 7 0.276 o1.5 Prism o0.059 (PMMA) Beam axis FT-Z30 o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Enclosure (PC) Beam axis 0.5 3 0.118 0.020 1.75 0.069 8.5 3.9 0.154 0.335 (o2.5) (o0.098) Model No. tube (m-PPE) FT-Z20HBW 11 0.433 0.5 0.020 7.5 2-o2.2 o0.087 hole 0.295 o1.3 (30) o0.051 (1.181) 5.5 0.217 2.2 0.087 12 Reflector (PC) 0.472 (o2.5) (o0.098) 4.3 0.169 2,000 78.740 Center of beam axis FT-Z30E Free-cut 12 0.472 3.4 11 0.433 0.134 3 0.118 8 0.315 3.5 0.138 Beam axis 2 0.079 Reflector (PMMA) 1.75 0.069 Lens (PMMA) 2,000 78.740 (30) (1.181) o1.3 o0.051 (o2.5) (o0.098) o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 2-o2.2 o0.087 hole 5.5 0.217 7.5 0.295 Small Spot Wide Beam Convergent Reflective Type Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Free-cut o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Flat Type Fiber Options o2.2 o0.087 hole, o3.6 o0.142 spot facing, 1.4 0.055 deep 4-R1 R0.039 o1 o0.039 (30) (1.181) (o2) (o0.079) Model No. tube (m-PPE) Inner pipe [Stainless steel (SUS304)] Enclosure (PC) 1.05 0.041 Sleeve Chemical / Oilresistant o1 o0.039 1,000 39.370 Cylindrical Type 0.6 0.024 3.5 0.138 FT-V30 1.2 0.047 2 2.5 0.079 0.098 Square Head Type Retroreflective Type 1,000 39.370 4-R1 R0.039 Enclosure (PC) 10 0.394 2.5 (o2.0) (o0.079) Model No. tube (m-PPE) 0.098 Inner pipe [Stainless steel (SUS304)] 1 o0.5 o0.020 fiber core x 1 (PMMA) 7 0.039 2.1 Sheath o1 o0.039 (Polyethylene) 0.083 0.276 5 0.197 o2.2 o0.087 (o4) (o0.157) protective tube (Fluorine resin) 10 0.394 3.5 0.138 o2.2 o0.087 hole, o3.6 o0.142 spot facing, 1.4 0.055 deep 0.5 0.020 Threaded Type Narrow Beam 2,000 78.740 o2.2 o0.087 Super Quality 12 Reflector (PC) 0.472 5.5 2.2 0.087 0.217 8.5 0.335 3.9 0.154 1.75 3 0.069 0.118 0.5 0.020 7.5 0.295 2,000 78.740 2-o2.2 o0.087 hole o1.3 (30) o0.051 (1.181) (o2.5) (o0.098) o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 0.5 0.020 4.3 0.169 11 0.433 Beam axis Enclosure (PC) (o2.5) (o0.098) Model No. tube (m-PPE) (o2.5) (o0.098) Model No. tube (m-PPE) FT-V40 Enclosure (PC) FT-Z30 Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 54 New product introduction Tough Fiber Fiber Selection Guide Model DIMENSIONS (Unit: mm in) Earlier models comparison table Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Thru-beam type fibers FT-Z30EW Free-cut FT-Z30H Free-cut 3 0.118 Choose by shape/ application How to read Model No Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. 12 2-o2.2 o0.087 0.472 3.4 11 hole 0.433 0.134 8 0.315 3.5 0.138 2,000 78.740 (30) (1.181) o1.3 o0.051 3 0.118 Reflector (PMMA) 1.75 0.069 8 0.315 2,000 78.740 (30) (1.181) o1.3 o0.051 (o2.5) (o0.098) 3.5 0.138 o0.75 o0.030 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 5.5 2 0.079 0.217 7.5 1.75 0.295 0.069 Lens (PMMA) 2-o2.2 o0.087 hole Enclosure (PC) Enclosure (PC) Lens (PMMA) 12 0.472 3.4 11 0.433 0.134 Beam axis (o2.5) (o0.098) o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Beam axis 5.5 0.217 7.5 0.295 (o2.5) (o0.098) Model No. tube (m-PPE) 2 0.079 (o2.5) (o0.098) Model No. tube (m-PPE) Fibers Super Quality FT-Z30HW Free-cut Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant 12 0.472 2,000 78.740 (30) 3.4 (1.181) 11 0.134 0.433 (o2.5)(o0.098) o1.3 o0.051 3 0.118 8 0.315 Beam 3.5 0.138 axis Lens (PMMA) 2 0.079 5.5 0.217 1.75 0.069 Semi-custom fibers o3.2 o0.126 hole, o5.6 o0.220 11 2,000 78.740 spot facing, 2.2 0.087 deep 0.433 3.5 0.138 4-R1 R0.039 1 0.039 3.5 0.138 Enclosure (PC) 1.05 0.041 (30) o1.3 o0.051 3.5 0.138 (1.181) 7 14 0.276 0.551 (o2.5) (o0.098) Model No. tube (m-PPE) 1.6 Inner pipe [Stainless steel(SUS304)] 0.063 7 2.7 0.106 o2.4 o0.094 0.276 Beam axis Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 3 0.118 7 0.276 Free-cut 70.276 o2.4 o0.094 14 0.551 Prism (PMMA) Beam axis 0.5 0.020 (30) (1.181) 4.3 0.169 (o2.5) (o0.098) o1.3 o0.051 3.9 0.154 2-o2.2 o0.087 hole Reflector (PC) 2.2 0.087 FT-Z30H Center of beam axis Reflector (PC) 2.2 0.087 8.5 0.335 5.5 0.217 12 0.472 12 0.472 5.5 0.217 2,000 78.740 2,000 78.740 2-o2.2 o0.087 hole (30) (1.181) 3.9 0.154 (o2.5) (o0.098) 4.3 0.169 o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 0.5 0.020 7.5 0.295 11 0.433 Enclosure (PC) Beam axis 1.75 0.069 0.5 0.020 3 0.118 o1.3 o0.051 (o2.5) (o0.098) Model No. tube (m-PPE) o1 o0.039 fiber core x 1 (PMMA) 0.6 Sheath o1.3 o0.051 (Polyethylene) 0.024 FT-Z40W 1 0.039 (o2.5) (o0.098) Model No. tube (m-PPE) Beam axis 11 0.433 0.5 0.020 7.5 1.75 0.069 0.295 (o2.5) (o0.098) Model No. tube (m-PPE) Free-cut 3.5 0.138 1.2 0.047 3.5 0.138 o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Enclosure (PC) 2-o2.2 o0.087 hole 7.5 0.295 FT-Z40HBW 3.5 0.138 Fiber Dimensions o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Enclosure (PC) Liquid Leak / Liquid Detection Fiber Options Free-cut 8.5 0.335 Small Spot Narrow Beam FT-Z30W 2,000 78.740 o3.2 o0.126 hole, o5.6 o0.220 spot facing, 2.2 0.078 deep 4-R1 R0.039 (30)(1.181) o1.3 o0.051 (o2.5) (o0.098) Model No. tube (m-PPE) Inner pipe [Stainless steel (SUS304)] Enclosure (PC) 1.05 0.041 o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) FT-Z802Y Free-cut 4 0.157 3 0.118 2-o3.2 o0.126 (7.3) (0.287) 13 0.512 FT-Z30W (1) (0.039) 2,000 78.740 (5.8) (0.228) 15 0.591 7.5 0.295 6 0.236 7 0.276 Beam axis o2.2 o0.087 55 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Retroreflective type fibers FR-KZ22E Free-cut Reflector 15.8 0.622 14.7 0.579 0.7 0.028 1.45 0.057 FR-KZ50E Fiber 2-M1.4 x 0.3 0.012 5.2 0.205 Prism (PC) Base (ABS) Enclosure (ABS) Reflector (PMMA) 11.2 0.441 2,000 78.740 (30) 2-o1 o0.039 (1.181) (3.7) (0.146) (o2) (o0.079) Model No. tube (m-PPE) Mounting bracket [Stainless steel (SUS303)] 11 9 7.5 0.433 0.354 0.295 2.2 0.087 25 0.984 3 0.118 3.7 0.146 9.5 0.374 Tough Fiber Free-cut 1.95 0.077 5 0.197 New product introduction o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Beam axis Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table Fiber Beam axis 1 0.039 2 0.079 (30) (1.181) Prism (PC) 1.5 0.059 2 0.079 5 0.197 9 4 0.157 0.354 Assembly dimensions with MS-FD-2 (attached mounting bracket) 9.5 0.374 21 0.827 3.7 0.146 2,000 78.740 (30) 2-o1 o0.039 (1.181) (3.7) (0.146) Beam axis 10.2 0.402 4 0.157 5 0.197 3.3 0.130 1.2 0.047 4 0.157 14 0.551 7 0.276 Beam axis 9.5 0.374 12.2 3.7 0.146 0.480 Sleeve Cylindrical Type Flat Type (Accessory for FR-KZ50E) 10.1 0.398 19 28 1.102 0.748 10 0.394 (Effective reflector width) 10 0.394 (Effective reflector width) (2-R) Reflector (Norbornene resin) 1 0.039 Cover [Stainless steel (SUS304)] 3.2 0.126 10.2 0.402 3.3 0.130 Beam axis 4 0.157 14 0.551 7 0.276 2-M3 x 0.5 0.020 MS-FD-2 Mounting bracket [Stainless steel (SUS304)] FR-Z50HW Fiber 1 0.039 15 0.591 2,000 78.740 Enclosure(ABS) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Enclosure(PC) (Accessory for FR-KZ50H) 5 0.197 1.1 0.043 5.2 0.205 Beam axis FR-KZ50E 10.6 0.417 10 0.394 (Effective reflector width) 10 0.394 (Effective reflector width) (2-R) Reflector (Norbornene resin) Cover [Stainless steel (SUS304)] 3.2 0.126 1 0.039 4.3 0.169 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) 1 0.039 2,000 78.740 15 0.591 2-M3 x 0.5 0.020 Lens (BK7) 9.5 0.374 12.2 0.480 5 0.197 10.2 0.402 4 0.157 Heatresistant Vacuumresistant Fiber Options Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others 3.3 0.130 MS-FD-2 Mounting bracket [Stainless steel (SUS304)] 3.3 0.130 1.2 0.047 6 0.236 Beam axis 14 0.551 7 0.276 4 0.157 2-o2.2 o0.087 Enclosure(PC) 5.2 0.205 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) Reflective tape RF-13 (Accessory for FR-Z50HW) 0.5 0.020 FR-Z50W Rear surface (pressure-sensitive adhesive) Amplifiers FX-500 series FX-100 series 30 1.181 30 1.181 Reflective surface (Acrylic) FR-KZ50H Chemical / Oilresistant 2-o2.2 o0.087 Assembly dimensions with MS-FD-2 (attached mounting bracket) 4.6 0.181 28 19 1.102 0.748 Retroreflective Type Semi-custom fibers 4.6 0.181 9.5 0.374 10.1 0.398 (2-R) Free-cut Lens (BK7) 5.2 0.205 Reflector RF-003 Convergent Reflective Type 3.3 0.130 4 0.157 1.2 0.047 6FR-KZ22E 0.236 Narrow Beam Liquid Leak / Liquid Detection 4.3 0.169 (o2) (o0.079) Model No. tube (m-PPE) 5 0.197 Small Spot Wide Beam 10.6 0.417 5 0.197 1.1 0.043 Assembly dimensions with MS-FD-2 (attached mounting bracket) (3.7) (0.146) 2-M3 x 0.5 0.020 MS-FD-2 Mounting bracket [Stainless steel (SUS304)] Enclosure(ABS) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) 2,000 78.740 (30) 2-o1 o0.039 (1.181) Threaded Type o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Reflector RF-003 Super Quality Square Head Type Prism (PC) (2-R) 21 0.827 2-o1 o0.039 Fibers 3.3 0.130 5.2 0.205 (o2) (o0.079) Model No. tube (m-PPE) Enclosure (ABS) (30) (1.181) (o2) (o0.079) Model No. tube (m-PPE) 5.2 0.205 (3.7) (0.146) 12.2 3.7 0.146 0.480 Free-cut Fiber 2,000 78.740 25 0.984 3 0.118 6 0.236 FR-KZ50H 9.5 0.374 2-o1 o0.039 Beam-receiving side (Black) Beam-emitting 2 0.079 4 side (Gray) 0.157 (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Head block [Stainless steel (SUS303)] 2-M1.4 x 0.3 0.012 4 0.157 1.9 0.075 0.7 0.028 2 0.079 2,000 78.740 21.5 0.846 7.5 .039 0.295 ) o0 1.5 (2-o1 0.059 2 0.079 INDEX 56 Tough Fiber Fiber Selection Guide FD-30 Fibers Super Quality FD-31 2 o6.5 0.079 o0.256 2.7 0.106 o2 o0.079 Choose by shape/ application Earlier models comparison table Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers Model How to read Model No Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) New product introduction 10 0.394 o3 o0.118 -0.10 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Stainless steel (SUS303)] Opposing faces 5.5 0.217 thickness 1.8 0.071 [Stainless steel (SUS)] Free-cut 2,000 78.740 Resin plug(ABS) 1.8 0.071 (20) (0.787) o6.5 o0.256 (19.7) (0.776) 10.2 0.402 o1 M3 x 0.5 o0.039 (o4.33) 0.020 (o0.170) Toothed lock washer M3 [Stainless steel (SUS)] (0.3) (0.012) o2.2 o1.8 o0.087 o0.071 (o2) (o0.079) Model No. tube (m-PPE) 2 0.079 2.7 0.106 Free-cut Square Head Type 2 0.079 10 0.394 2.7 0.106 Cylindrical Type 1.8 0.071 o2 End bracket o0.079 [Stainless steel (SUS303)] Flat Type (o2) (o0.079) Model No. tube (m-PPE) M3 x 0.5 0.020 17 0.669 12 0.472 1.2 0.047 2,000 78.740 30 1.181 1.8 0.071 o1 o0.039 Beam-emitting side (o2) (o0.079) Model No. tube(m-PPE) Beam-receiving side o2.3 o0.091 Details of M3 x 0.5 sensing part 0.020 2.8 0.110 o3 o0.118 Sheath o1.3 o0.051 o1.3 o0.051 (Polyethylene) End bracket [Stainless steel (SUS303)] Sheath o1 o0.039 (Polyethylene) Hexagon nut M3 [Stainless steel (SUS304)] Toothed lock washer M3 [Stainless steel (SUS304)] Beam-receiving o0.25 o0.010 fiber core x 9 (PMMA) Beam-emitting o0.5 o0.020 fiber core x 1 (PMMA) FD-32GX Free-cut FD-40 Convergent Reflective Type 18 0.709 12 0.472 1.2 0.047 o4.5 o0.177 o2.3 o0.091 Retroreflective Type Liquid Leak / Liquid Detection Free-cut Narrow Beam Vacuumresistant M3 x 0.5 0.020 Toothed lock washer M3 [Stainless steel (SUS304)] o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) Toothed lock washer M3 [Stainless steel (SUS304)] Hexagon nut M3 [Stainless steel (SUS304)] Small Spot Heatresistant o0.5 o0.020 Fiber core x 1 (Acrylic) Sheath o1 o0.039 (Polyethylene) FD-32G o6.5 o0.256 5.5 0.217 2,000 78.740 (30) (1.181) 2-o1 o0.039 Sleeve Chemical / Oilresistant (o2) (o0.079) Model No. tube (m-PPE) o3 o0.118 -0.1 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Stainless steel (SUS303)] o6.5 o0.256 5.5 0.217 o1 o0.039 (30) (1.181) 1.8 0.071 o2 o0.079 Opposing faces 5.5 0.217 thickness 1.8 0.071 [Stainless steel (SUS304)] FD-31W Threaded Type Wide Beam 2,000 78.740 10 0.394 o6.5 o0.256 5.5 0.217 (2.5) (0.098) o3.8 o0.150 1,000 39.370 300 11.811 6 0.236 (2.5) (0.098) (30) (1.181) 700 27.559 (Allowable cutting range) o4.5 o1 Beam-emitting o0.177 o0.039 side o1.3 o0.051 M3 x 0.5 0.020 End bracket [Stainless steel (SUS303)] Toothed lock washer M3[Stainless steel (SUS304)] Crimping part FD-31W (o5.1) (o0.201) Model No. tube (m-PPE) Crimping part Beam-receiving side Sheath o1 o0.039 (Polyethylene) Sheath o1.3 o0.051 (Polyethylene) Intermediate fixing bracket [Stainless steel (SUS303)] Hexagon nut M3 [Stainless steel (SUS304)] 2 2,000 78.740 Resin plug(ABS) 2.4 (20) 0.094 (0.787) 12 0.472 o8.5 0.079 o0.335 3.5 0.138 o2.5 o0.098 o4 o0.157 -0.10 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Brass (Nickel plated)] Opposing faces 7 0.276 thickness 2.4 0.094 [Brass (Nickel plated)] M4 x 0.7 0.028 (19.7) (0.776) 10.2 0.402 (0.3) (0.012) o2.2 o1.8 o1 o0.087 o0.071 o0.039 (o4.33) (o0.170) (o2) (o0.079) Model No. tube (m-PPE) Toothed lock washer M4 [Brass (Nickel plated)] Protective tube (Polyolefin tube included SUS304 spiral tube) Details of sensing part Fiber Options Beam-receiving o0.25 o0.010 fiber core x 9 (PMMA) Beam-emitting o0.5 o0.020 fiber core x 1 (PMMA) Semi-custom fibers FD-41 o8.5 o0.335 Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers INDEX 2 0.079 3.5 0.138 12 0.472 o2.5 o0.098 2,000 78.740 2.4 0.094 (30) (1.181) o1 o0.039 (o2) (o0.079) Model No. tube (m-PPE) -0.1 -0.004 o4 o0.157-0.13 -0.005 Mounting reference surface (Screw periphery) End backet [Stainless steel (SUS303)] Opposing faces 7 0.276 thickness 2.4 0.094 [Stainless steel (SUS304)] Toothed lock washer M4 [Stainless steel (SUS304)] FD-32GX o0.5 o0.020 Fiber core x 1 (Acrylic) Sheath o1 o0.039 (Polyethylene) M4 x 0.7 0.028 FD-41SW FD-41S Free-cut Free-cut o8.5 o0.335 7 0.276 3.5 10 0.138 0.394 40 1.575 12 0.472 5 Allowable 10 0.197 bending 0.394 range o2.5 o0.098 M4 x 0.7 0.028 Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] FD-32G o1.48 o0.058 Sleeve [Stainless steel (SUS304)] 2,000 78.740 2-o1 (30) o0.039 2.4 0.094 (1.181) (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) FD-41W Free-cut FX-500 series FX-100 series Free-cut 3.5 0.138 o8.5 o0.335 7 0.276 40 1.575 10 0.394 Allowable bending range 5 0.197 12 0.472 10 0.394 o1.48 o2.5 o0.098 o0.058 Sleeve [Stainless steel M4 x 0.7 0.028 (SUS304)] Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] 2.4 0.094 2,000 78.740 2-o1 (30) o0.039 (1.181) (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) o8.5 o0.335 2 0.079 7 0.276 3.5 0.138 12 0.472 2.4 0.094 2,000 78.740 (30) (1.181) 2-o1.3 o0.051 o3 o0.118 End bracket [Stainless steel (SUS303)] Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] M4 x 0.7 0.028 (o2.5) (o0.098) Model No. tube(m-PPE) o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 57 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-42G Free-cut FD-42GW 25 0.984 5 12 0.472 0.197 1.2 0.047 2,000 78.740 (30) (1.181) 2.4 0.094 o8.5 o0.335 7 0.276 o1 o0.039 o1.3 o0.051 o2.3 o0.091 Beam-receiving side (o2) (o0.079 ) Model No. tube (m-PPE) o4 o0.157 M3 x 0.5 0.020 M4 x 0.7 0.028 Beam-emitting side Sheath o1 o0.039 (Polyethylene) Toothed lock washer M4 [Stainless steel (SUS304)] 1.2 0.047 25 0.984 5 0.197 12 0.472 2.4 0.094 o2.3 o0.091 M3 x 0.5 0.020 M4 x 0.7 0.028 (30) (1.181) 3.5 0.138 Details of sensing part Details of sensing part Fiber Selection Guide Model o1 o0.039 Hexagon nut M4 [Stainless steel (SUS304)] Toothed lock washer M4 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] Hexagon nut M4 [Stainless steel (SUS304)] 2,000 78.740 Beam-emitting side o1.3 o0.051 Beam-receiving side o4 (o2) (o0.079) Model No. tube (m-PPE) o0.157 Sheath o1 o0.039 (Polyethylene) Sheath o1.3 o0.051 (Polyethylene) End bracket [Stainless steel (SUS303)] Sheath o1.3 o0.051 (Polyethylene) 3.5 0.138 Tough Fiber Free-cut o8.5 o0.335 7 0.276 New product introduction Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Beam-receiving o0.25 o0.010 fiber core x 9 (PMMA) Beam-receiving o0.25 o0.010 fiber core x 9 (PMMA) Square Head Type Beam-emitting o0.5 o0.020 fiber core x 1 (PMMA) Beam-emitting o0.5 o0.020 fiber core x 1 (PMMA) Cylindrical Type Sleeve FD-60 FD-61 Free-cut o11 o0.433 15 0.591 2 0.079 5.5 0.217 2 0.079 o4.5 o0.177 o6 o0.236 -0.10 -0.004 -0.13 -0.005 Mounting reference surface (Screw periphery) End bracket [Brass (Nickel plated)] 2,000 78.740 Resin plug (ABS) (20) (0.787) o11 o0.433 (19.7) (0.776) 10.2 0.402 (0.3) (0.012) o2.2 o1.8 o2.2 (o4.33) o0.087 o0.071 M6 x 0.75 o0.087 (o0.170) (o3.2) (o0.126) Model No. tube (m-PPE) 0.030 Toothed lock washer M6 [Brass (Nickel plated)] Opposing faces 10 0.394 thickness 2 0.079 [Brass (Nickel plated)] FD-61G 2 0.079 Free-cut 5.5 0.217 o4.5 o0.177 15 0.591 2 0.079 2,000 78.740 (30) (1.181) o11 o0.433 10 0.394 15 0.591 2 0.079 (30) (1.181) -0.1 -0.004 o6 o0.236-0.13 -0.005 (o3.2) (o0.126) Model No. tube (m-PPE) o1 o0.039 Fiber core x 1 (Acrylic) Sheath o2.2 o0.087 (Polyethylene) Mounting reference surface (Screw periphery) End bracket [Stainless steel (SUS303)] Opposing faces 10 0.394 thickness 2 0.079 [Stainless steel (SUS304)] Toothed lock washer M6 [Stainless steel (SUS304)] M6 x 0.75 0.030 2-o2.2 o0.087 Details of sensing part Sheath o2.2 o0.087 (Polyethylene) Toothed lock washer M6 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] M6 x 0.75 0.030 5.5 0.217 Free-cut o11 o0.433 10 0.394 5.5 10 0.217 0.394 Allowable 5 0.197 bending 10 0.394 range o2.5 o0.098 Sleeve [Stainless steel (SUS304)] 2 0.079 o3.5 o0.138 M6 x 0.75 0.030 Toothed lock washer M6 [Stainless steel (SUS304)] Hexagon nut M6 [Stainless steel (SUS304)] 2,000 78.740 2-o2.2 o0.087 (30) (1.181) (o3.2) (o0.126) Model No. tube (m-PPE) End bracket [Stainless steel (SUS303)] o4.5 o0.177 Hexagon nut M6 [Stainless steel (SUS304)] Toothed lock washer M6 [Stainless steel (SUS304)] Fiber Options Semi-custom fibers Fiber Dimensions Retroreflective Type Reflective Type Free-cut 15 0.591 2 0.079 Liquid Leak / Liquid Detection Thru-beam Type FD-62 Free-cut 2 0.079 5.5 0.217 Chemical / Oilresistant o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) Beam-emitting o1 o0.039 fiber core x 1 (PMMA) o11 o0.433 10 0.394 Retroreflective Type 15 0.591 Beam-receiving o0.25 o0.010 fiber core x 16 (PMMA) FD-61W Wide Beam Vacuumresistant FD-61S (o3.2) (o0.126) Model No. tube (m-PPE) Hexagon nut M6 [Stainless steel (SUS304)] Narrow Beam Heatresistant 40 1.575 2,000 78.740 Small Spot Convergent Reflective Type 2 0.079 o4.5 o0.177 o2.2 o0.087 Flat Type 2,000 78.740 2-o2.2 o0.087 (30) (1.181) o11 o0.433 10 0.394 5.5 0.217 (o3.2) (o0.126) Model No. tube (m-PPE) M6 x 0.75 0.030 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] Others -0.1 -0.004 o6 o0.236-0.13 -0.005 2 0.079 15 0.591 2 0.079 o4.5 o0.177 Hexagon nut M6 [Stainless steel (SUS304)] Mounting reference surface (Screw periphery) Toothed lock washer M6 [Stainless steel (SUS304)] 2,000 78.740 2-o2.2 o0.087 (30) (1.181) (o3.2) (o0.126) Model No. tube (m-PPE) o1.5 o0.059 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) End bracket [Stainless steel (SUS303)] M6 x 0.75 0.030 Amplifiers FX-500 series FX-100 series INDEX 58 New product introduction Tough Fiber Fiber Selection Guide FD-64X FD-A16 Protective tube Polyolefin tube included SUS304 spiral tube 22 0.866 2 15 0.079 10 0.591 0.394 Earlier models comparison table Details of sensing part Square Head Type Cylindrical Type 5.5 0.217 Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant 2-o2.2 o0.087 4.5 0.177 5.1 0.201 (30) (1.181) (o5.1) (o0.201) Resin plug (ABS) FD-AL11 Free-cut B Beam-receiving side A Beam-emitting side Enclosure (PC) 7 0.276 Sheath o2.2 o0.087 (Polyethylene) View A View B Beam-emitting o1 o0.039 fiber core x 1 (PMMA) Beam-receiving o0.25 o0.010 fiber core x 16 (PMMA) FD-E13 20 0.787 13 0.512 5 0.197 2.5 0.098 Details of sensing part 2.5 0.098 1 0.039 o0.48 o0.019 2-o2.2 o0.087 15 0.591 3 0.118 5 0.197 o0.25 o0.010 x 16 fiber core (PMMA) Sheath o2.2 o0.087 (Polyethylene) 5 0.197 2-o2.2 o0.087 4.5 0.177 5.1 0.201 4 0.157 (Set screw tightening range) (30) o1.5 o0.059 o0.9 o0.035 (1.181) 2,000 78.740 2-M3 x 0.5 0.020 20 15 0.787 0.591 Head block (LCP) (o2.5) (o0.098) 1,000 39.370 6 0.236 (1) (0.039) 10.7 0.421 (3.1) (0.122) Enclosure (PPS) 7 11 11.6 0.276 0.433 0.457 10.85 0.427 Sleeve [Stainless steel (SUS304)] Details of sensing part Sensing part o0.25 o0.010 fiber core x 32 (emitter / receiver alternating line) Resin plug (ABS) (o2.5) (o0.098) Model No. tube (m-PPE) (o0.9) (o0.035) Protective tube (Polyolefin) End bracket [Stainless steel (SUS303)] o0.125 o0.005 fiber core x 2 (PMMA) (each beam-emitting part and beam-receiving part) FD-EG30 FD-E23 o3 o0.118 Semi-custom fibers (30) (1.181) 2-o2.2 o0.087 4.5 0.177 5.1 0.201 (30) (1.181) Resin plug (ABS) (o1.6) (o0.063) Protective tube (Polyolefin) 5 0.197 15 0.591 1,000 39.370 6 0.236 (1) (0.039) (3.4) (0.134) Retroreflective Type End bracket [Stainless steel (SUS303)] Reflective Type 5.5 1.2 0.217 0.047 10.7 0.421 Beam-receiving 7 11 11.6 side 0.276 0.433 0.457 Beam-emitting side (o3) (o0.118) Model No. tube (m-PPE) Details of sensing part Sleeve [Stainless steel (SUS304)] 2-o2.2 o0.087 4.5 0.177 5.1 0.201 (o3) (o0.118) Resin plug (ABS) (o1.6) (o0.063) Protective tube (Polyolefin) (o3) (o0.118) o0.63 o0.025 Thru-beam Type Others 2,000 78.740 2-o2.2 o0.087 8 0.315 9 0.354 Beam axis 10.7 0.421 Liquid Leak / Liquid Detection Fiber Dimensions 15 0.591 2 0.079 28 1.102 3.6 0.142 2-o3.3 o0.130 1,000 39.370 6 0.236 (2.5) (0.098) (5.8) (0.228) 2 0.079 Vacuumresistant Fiber Options Lens (Norbornene resin) 11 11.6 7 0.276 0.433 0.457 Crimping part o11 o0.433 End bracket M6 x 0.75 0.030 (o5.1) (o0.201) Model No. tube (m-PPE) [Stainless steel (SUS303)] Hexagon nut M6 [Stainless steel (SUS304)] Toothed lock washer M6 [Stainless steel (SUS304)] o0.25 o0.010 fiber core x 9 (PMMA) (each beam-emitting part and beam-receiving part) Sleeve Flat Type o3.8 o0.150 o4.5 o4.5 o0.177 o0.177 How to read Model No Threaded Type Free-cut Choose by shape/ application Super Quality Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers Model Fibers Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) 16 0.630 o6.5 o2.3 o0.256 o0.091 Details of sensing part 2.8 0.110 500 19.685 6 0.236 FD-E13 10.7 (1) (0.039) 0.421 1.8 (3.6) (0.142) 0.071 Beam-receiving 7 11 11.6 side 0.276 0.433 0.457 Beam-emitting side (o3) (o0.118) Model No. tube (m-PPE) M3 x 0.5 0.020 End bracket [Stainless steel (SUS303)] Hexagon nut M3 [Stainless steel (SUS304)] Toothed lock washer M3 [Stainless steel (SUS304)] Beam-emitting o0.25 o0.010 fiber core x 1 (PMMA) Beam-receiving o0.125 o0.005 fiber core x 9 (PMMA) Amplifiers FX-500 series FX-100 series INDEX Beam-receiving o0.125 o0.005 fiber core x 9 (PMMA) Beam-emitting o0.25 o0.010 fiber core x 1 (PMMA) 59 Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-EG30S FD-EG31 2-o2.2 o0.087 Sleeve [Stainless steel (SUS304)] 15 0.591 15 0.591 5.5 0.217 1.8 0.071 1,000 39.370 6 0.236 10.7 (1) (0.039) 0.421 (3.6) (0.142) Beam-receiving 7 11 11.6 side 0.433 0.457 Beam-emitting 0.276 M3 x 0.5 0.020 side (o3) (o0.118) Model No. tube (m-PPE) Hexagon nut M3 [Stainless steel (SUS304)] Toothed lock washer M3 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] o6.5 o0.256 Details of sensing part 2.7 0.106 (o2.5) (o0.098) Resin plug (ABS) (o1.2) (o0.047) Protective tube (Polyolefin) 16 500 19.685 0.630 6 0.236 5.5 (1) (0.039) 1.3 0.051 1.8 10.7 0.217 0.421 0.071 (3.1) (0.122) Beam-receiving 7 11 11.6 side 0.276 0.433 0.457 Beam-emitting M3 x 0.5 0.020 side o6.5 o0.256 (o2.5) (o0.098) Model No. tube (m-PPE) End bracket [Stainless steel (SUS303)] Details of sensing part 2.8 0.110 Hexagon nut M3 [Stainless steel (SUS304)] Toothed lock washer M3[Stainless steel (SUS304)] Beam-receiving o0.125 o0.005 fiber core x 6 (PMMA) Beam-receiving o0.125 o0.005 fiber core x 9 (PMMA) FD-F4, FD-F41 Free-cut 500 19.685 2-o3.2 o0.126 mounting holes 5 0.197 (o3) (o0.118) Model No. tube (m-PPE) 14 0.551 o1 o0.039 x 2 (20) (0.787) 14 0.551 2,000 78.740 4 0.157 (4.44) (0.175) (1.0) (0.039) (o1.15) (o0.045) 13 0.512 2,000 78.740 (50) (1.969) Protective tube Range where cutting is not possible (17) Bending prohibited range (0.8) (0.669) (0.031) (10) Crimping part (0.039) o1 o0.039 x 2 Primary sheath: Polyethylene Secondary sheath: [PFA (fluorine resin)] Free-cut 5,000 196.850 3,000 118.110 30 1.181 7.8 0.307 Emission indicator 10 20 0.394 0.787 [PFA(Fluorine resin)] Sleeve Flat Type Narrow Beam Wide Beam Heatresistant Free-cut 1,000 39.370 Vacuumresistant Liquid Leak / Liquid Detection 1,000 39.370 (Allowable cutting range) (26) (1.024) (Bending prohibited range) 16 8 0.315 0.630 Beam-emitting side (Gray) Beam-receiving side (Black) o0.25 o0.010 fiber core x 4 (PMMA) Outer sheath o1 o0.039 (Polyethylene) (o3.1) (o0.122) Protective tube [PFA(Fluorine resin)] Threaded Type Chemical / Oilresistant FD-F8Y 2-o1 o0.039 Super Quality Retroreflective Type Fiber Fibers Convergent Reflective Type FD-EG31 FD-F71 Earlier models comparison table Small Spot (o4) (o0.157) Protective tube [PFA (fluorine resin)] 10 0.394 How to read Model No. Cylindrical Type Free-cut 20 0.787 6 0.236 13.5 25 0.531 0.984 FD-F41Y Choose by shape/ application Square Head Type Beam-emitting o0.125 o0.005 fiber core x 1 (PMMA) Beam-emitting o0.25 o0.010 fiber core x 1 (PMMA) 8 0.315 Model 5.1 0.201 (o3) (o0.118) Resin plug (ABS) (o1.6) (o0.063) Protective tube (Polyolefin) Tough Fiber Fiber Selection Guide 2-o2.2 o0.087 4.5 0.177 (30) (1.181) o2.3 o0.091 4.5 0.177 5.1 0.201 (30) (1.181) o0.8 o0.031 New product introduction Fiber Options o2.2 o0.087 x 2 (o6) (o0.236) protective tube (Fluorine resin) 10 0.394 Semi-custom fibers 22 0.866 SUS mounting bracket 17 0.669 10 0.394 17.7 12.2 0.480 0.697 SUS mounting bracket (FD-71) mounting diagram 6.2 0.244 Details of sensing part 15.5 10.5 0.413 0.610 17 0.669 FD-F71 Mounting holes (for tying band) SUS mounting bracket (9.4) (0.370) 0.3 0.012 12 0.472 10 0.394 10 15 0.394 0.591 11.5 o4.2 o0.165 thru-holes 0.453 Material: [PFA(Fluorine resin)] Material: Stainless steel (SUS316) 10.3 0.406 PVC mounting bracket Free-cut 30 1.181 0.3 0.012 5.5 0.217 11 0.433 FD-FA93 7.8 0.307 20.3 28.3 0.799 1.114 PVC mounting bracket (FD-71) mounting diagram 6.5 3 0.118 0.256 0.9 0.035 2.5 0.098 5.2 0.205 22.2 0.874 4 0.157 11 Welding part 0.433 Material: PVC 5.2 0.205 o0.25 o0.010 fiber core x 9 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series 2,000 78.740 10 0.394 25 0.984 FD-F71 11.5 0.453 10 0.394 Sensing part (emitter / receiver alternating line) 17.1 0.673 (o0.25 o0.010 fiber core x 18) Enclosure (ABS) 30 1.181 5.7 0.224 8.75 0.344 Fiber Dimensions PVC mounting bracket 2-o1.3 o0.051 3 0.118 2.5 0.098 INDEX 60 DIMENSIONS (Unit: mm in) New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-H13-FM2 Free-cut FD-H18-L31 Free-cut Details of sensing part 16 0.630 15 0.591 5 0.197 5.5 0.217 o1.5 o0.059 fiber core x 2 7 0.276 10.75 0.423 2,000 78.740 How to read Model No 2,000 78.740 20 0.787 6.5 0.256 2.7 0.106 A 19 0.748 Screw tightening face Earlier models comparison table o5 o0.197 M6 x 0.75 0.030 o2.2 o0.087 x 2 (Fluorine resin) Opposing faces 10 0.394, thickness 2 0.079 Toothed lock washer o11 o0.433 8 0.315 4 0.157 5 0.197 Fibers Super Quality 2-M3 x 0.5 0.020 Head [Stainless steel (SUS)] Holder [Stainless steel (SUS)] View A o4.6 o0.181 Threaded Type A o2.2 o0.087 x 2 (Fluorine resin) End bracket (Brass) Emitter / Receiver fiber o1.5 o0.059 x 1 Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant FD-H20-21 FD-H20-M1 Details of sensing part Beam-receiving part: o50 m o1.969 mil x 440 Beam-emitting part: o50 m o1.969 mil x 440 1,000 39.370 60 35 30 2.362 1.378 o3.1 1.181 16.7 18.3 o10 o0.122 0.657 0.720 o0.394 5 0.197 o5 o0.197 Emitter mark o4 o5 o0.197 o0.157 o2.9 o0.114 M4 x 0.7 Liner + braid tube Joint 0.028 [Stainless steel (SUS)] 27 1.063 20 0.787 5 0.197 o2.2 o0.087 Beamemitting side Beam3.5 receiving 0.138 side o3 o0.118 Toothed lock washer o8.5 o0.335 [Stainless steel (SUS)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)] Heatresistant Heat & cold-resistant Details of specifications sensing part Ordinary temperature specifications Joint [Brass (Nickel plated)] Beam-receiving part: 28 1,000 inside diameter o1.1 o0.043 1.102 39.370 25 150 60 5 outside diameter o1.6 o0.063 18.3 16.7 5.906 0.984 2.362 0.197 0.657 0.720 Beamfiber core bundle x 1 15 5 0.591 0.197 receiving 5.5 D side 0.217 o2.2 o0.087 BeamP o9 o0.354 Screw emitting o6 o4.2 o0.165 (Silicone) tightening face side o0.236 Fixing plug (PA) o5 End bracket Beam-emitting part: o3.5 o0.197 Fixing bracket o0.138 [Brass (Nickel plated)] o1.1 o0.043 fiber [Brass (Nickel plated)] core bundle x 1 M6 x 0.75 Opposing faces 10 0.394, o2.9 o0.114 (Silicone) 0.030 thickness 2 0.079 Toothed lock washer o11 o0.433 Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions FD-H25-L43 FD-H25-L45 33.2 1.307 21.7 0.854 5 0.197 4.5 0.177 Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 3,000 118.110 34.5 1.358 23 0.906 19.5 0.768 Ordinary temperature specifications (150) (5.906) 10 0.394 BeamA emitting side (o4.33) (o0.170) BeamA receiving side o2.2 o0.087 x 2 21 0.827 2 0.079 o3.8 o0.150 Thru-beam Type Retroreflective Type 6.5 0.256 Heat-resistant specifications o2.9 o0.114 5 0.197 4.5 0.177 6.5 0.256 Heat-resistant specifications o2.9 o0.114 2 0.079 Slit mask [Stainless steel (SUS)] Beam axis Enclosure (Heat-resistant resin) o5 o0.197 (24.2) (0.953) View A o1.2 o0.047 (Beam-receiving fiber o1.5 o0.059) fiber core x 1 19.5 0.768 10 0.394 BeamA emitting side (o4.33) (o0.170) BeamA receiving side o2.2 o0.087 x 2 o3.8 o0.150 Tube [Stainless steel (SUS)] 2-mounting holes for M3 countersunk head screw Fiber holder (Heat-resistant resin) Ordinary temperature specifications (150) (5.906) 21 0.827 Tube [Stainless steel (SUS)] Prism (BK7) 3,000 118.110 2-mounting holes for M3 countersunk head screw Prism (BK7) Slit mask [Stainless steel (SUS)] Beam axis Fiber holder (Heat-resistant resin) Enclosure (Heat-resistant resin) o5 o0.197 (24.2) (0.953) View A o1.2 o0.047 (Beam-receiving fiber o1.5 o0.059) fiber core x 1 Resin plug (PA) Resin plug (PA) Fixing bracket [Brass (Nickel plated)] Fixing bracket [Brass (Nickel plated)] 61 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-H30-KZ1V-S FD-H30-L32 21.7 (0.854 ) 15 0.591 1,000 39.370 30 1.181 11 0.433 o4 o0.157 Glass lens (BK7) o3.6 o0.142 9.5 0.374 End bracket [Stainless steel (SUS)] Enclosure [Stainless steel (SUS)] 4.6 0.181 2-o1 o0.039 vent holes 10.75 0.423 Mounting cap nut opposing faces 8 0.315 [Stainless steel (SUS)] Joint [Stainless steel (SUS)] Liner + braid tube [Stainless steel (SUS)] 12.2 0.480 10.2 0.402 9.5 0.374 4.6 0.181 t 1.2 t 0.047 6 0.236 Holder [Stainless steel (SUS)] View A o4.6 o0.181 Emitter / Receiver fiber o1.2 o0.047 fiber core x 1 FD-H30-L32V-S 6.5 0.256 o4 o0.157 10.75 0.423 (1.2 0.047) 19 0.748 8 0.315 o3.6 o0.142 30 1.181 11 0.433 Details of sensing part 4 0.157 o4 o0.157 4 0.157 o4.6 o0.181 3.4 (0.134 ) Mounting cap nut opposing faces 8 0.315 [Stainless steel (SUS)] Wide Beam 90 3.543 Allowable bending range 5 0.197 27 1.063 20 0.787 10 0.394 o4 o0.157 o2.1 o0.083 [Stainless steel (SUS)] o3 o0.118 1,000 39.370 35 60 1.378 30 2.362 16.7 18.3 1.181 0.657 0.720 o2.2 5 o0.087 0.197 o5 o0.197 o2.9 o0.114 Resin plug (PA) o10 o0.394 Joint o3.1 o5 o0.197 o0.122 M4 x 0.7 0.028 Liner + braid tube [Stainless steel (SUS)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)] Toothed lock washer o8.5 o0.335 [Stainless steel (SUS)] Beam-emitting part: o50 m o1.969 mil x 380 o2.7 o0.106 Details of sensing part Heat & cold-resistant Ordinary temperature specifications specifications 3 22 2,000 Beam-receiving part: 0.118 0.866 78.740 inside diameter o1.8 o0.071 150 30 60 5 outside diameter o2.2 o0.087 5.906 1.181 2.362 0.197 17 fiber core bundle x 1 5 0.669 0.197 o4 o0.157 [Stainless steel (SUS)] M6 x 0.75 0.030 [Stainless steel (SUS)] FD-H35-M2S6 o1.8 o0.071 fiber core bundle x 1 emitting and receiving Beam-emitting part: o1.3 o0.051 fiber core bundle x 1 16.7 0.657 o4 o0.157 [Stainless steel (SUS)] M6 x 0.75 0.030 [Stainless steel (SUS)] Toothed lock washer o11 o0.433 [Stainless steel (SUS)] o5 o0.197 o10 o0.394 Joint [Brass o3 o0.118 (Nickel plated)] (Silicone) Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Semi-custom fibers 16.7 0.657 Beamreceiving side o2.2 o0.087 Beamemitting side Fixing plug (PA) Fixing bracket [Brass (Nickel plated)] Opposing faces 10 0.394, thickness 2 0.079 [Stainless steel (SUS)] Toothed lock washer o11 o0.433 [Stainless steel (SUS)] o5 o0.197 [Stainless steel (SUS)] o10 o0.394 o3 o0.118 o5 o0.197 (Silicone) o3.8 o0.150 [Stainless steel (SUS)] FD-HF40Y 18.3 0.720 18.3 0.720 P Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Free-cut Amplifiers o5 o0.197 o2.8 o0.110 [Stainless steel (SUS)] Chemical / Oilresistant FD-H35-M2 D o5 o0.197 Heat & cold-resistant Ordinary temperature specifications specifications 2,000 22 60 78.740 0.866 2.362 60 5 30 150 2.362 0.197 1.181 5.906 5 17 5 0.197 0.669 0.197 Retroreflective Type Fiber Options Note: The FD-H30-L32V-S is a set with the FD-H30-L32V, photo-terminal, and atmospheric side fiber. Refer to p.66 for dimensions of the atmospheric side fiber and photo-terminals. Details of sensing part Cylindrical Type Convergent Reflective Type 10 Beam-receiving part: 0.394 o50 m o1.969 mil x 380 End bracket [Stainless steel (SUS)] Liner + braid tube 2-M3 x 0.5 0.020 Enclosure [Stainless steel (SUS)] [Stainless steel (SUS)] Holder [Stainless steel (SUS)] Square Head Type Narrow Beam Joint [Stainless steel (SUS)] Rod prism (BK7) 5 0.197 3,000 118.110 Super Quality Small Spot FD-H35-20S 16.7 (0.657 ) Fibers Flat Type Note: The FD-H30-KZ1V-S is a set with the FD-H30-KZ1V, photo-terminal, and atmospheric side fiber. Refer to p.66 for dimensions of the atmospheric side fiber and photo-terminals. 20 0.787 Earlier models comparison table Sleeve Mounting bracket (MS-FD-2) 7 0.276 [Stainless steel (SUS)] 5.2 0.205 7 0.276 How to read Model No. Tube [Stainless steel (SUS)] End bracket [Stainless steel (SUS)] 2-M3 x 0.5 0.020 Head [Stainless steel (SUS)] 4 0.157 3.3 0.130 14 0.551 Choose by shape/ application Threaded Type 3.3 0.130 4 0.157 Model 18.3 0.720 A o2.2 o0.087 x 2 Fixing plug (PA) Fixing bracket [Brass (Nickel plated)] 5 0.197 2-M3 x 0.5 0.020 o4 o0.157 Tough Fiber Fiber Selection Guide A 4 0.157 Assembly dimensions with MS-FD-2 (attached mounting bracket) 15 0.591 2,000 78.740 16.7 0.657 16.7 6.5 0.657 0.256 o5 o4 o2.9 o0.197 o0.157 o0.114 8 0.315 19 0.748 o2.7 o0.106 5.2 0.205 20 0.787 7 0.276 4 0.157 o4 o0.157 New product introduction 500 o2.2 o0.087 o3.8 o0.150 Fixing plug (PA) [Stainless steel (SUS)] o5 o0.197 Fixing bracket [Stainless steel (SUS)] [Brass (Nickel plated)] Opposing faces 10 0.394, thickness 2 0.079 [Stainless steel (SUS)] 19.685 (50) (1.969) Protective tube Range where cutting is not possible (4.44) (0.175) (1.0) (0.039) (0.8) (0.031) (o1.15) (o0.045) 2,000 78.740 (17) Bending prohibited range (0.669) (10) Crimping part (0.394) (o4) (o0.157) Protective tube [PFA (fluorine resin)] FX-500 series o1 o0.039 x 2 (Polyethylene) FX-100 series INDEX 62 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table DIMENSIONS (Unit: mm in) FD-L10 Free-cut 19 0.748 7 0.276 2 0.079 Lens (PMMA) 12 0.472 4.5 0.177 Slit mask [Stainless steel (SUS304-CSP-H)] 2.5 0.8 0.031 0.098 3 0.118 12 0.472 Free-cut 7.2 0.283 7 0.276 8 0.315 FD-L20H Free-cut FD-L21 Free-cut 21 0.827 6.5 7 0.256 0.276 3 0.118 24 0.945 16 0.630 Heatresistant Enclosure (ABS) Liquid Leak / Liquid Detection 4 0.157 2,000 78.740 2-mounting holes for M3 countersunk head screw Enclosure (ABS) FD-L21W Free-cut 3 0.118 21 0.827 6.5 7 0.256 0.276 2,000 78.740 2-mounting holes for M3 countersunk head screw 16 0.630 24 0.945 Front film (Polyester) 4 0.157 Beam axis (2) (0.079) (19) (0.748) 0.5 o0.020 x 1 fiber ocore (Acrylic) Sheath o1 o0.039 (Polyethylene) Beam axis Front film (Polyester) (2) (0.079) Free-cut FD-L23 Free-cut 29 1.142 6.5 18 0.709 2.5 0.098 0.256 17 0.669 2,000 78.740 2-o1.3 o0.051 (15.3) 10 0.394 (0.602) 12 0.472 2 0.079 Enclosure (ABS) 2-mounting holes for M3 countersunk head screw 3.8 0.150 Beam axis Thru-beam Type 2.5 0.098 Beam-emitting side (Gray) 29 1.142 6.5 18 0.709 0.256 18 0.709 Beam-receiving side (Black) 2-mounting holes for M3 countersunk head screw 3.8 0.150 Beam axis (4.88) (0.192) o0.25 o0.010 fiber core x 9 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Enclosure (PC) FD-L30A Free-cut 2-mounting holes for M3 countersunk head screw 3.8 0.150 Beam axis FD-L21 Enclosure (ABS) o0.25 o0.010 fiber core x 9 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 3 0.118 2-o1.3 o0.051 o0.25 o0.010 fiber core x 9 (PMMA) Sheath o1.3 o0.051 (Polyethylene) (1.95) (0.077) (1.8) (0.071) Free-cut FD-L20H 3,000 118.110 Beam-emitting side (Gray) (17.3) (0.681) Beam-receiving side (Black) (5.3) (0.209) 20 0.787 Beam-emitting side (Gray) (16.3) (0.642) Beam-receiving (4.8) (0.189) side (Black) FD-L31A 29 1.142 18 0.709 6.5 2.5 0.098 0.256 3,000 118.110 2-o1.3 o0.051 (1.8) (0.071) Retroreflective Type Amplifiers 2-o1 o0.039 Enclosure (ABS) FD-L22A Fiber Dimensions INDEX o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) 6 0.236 2-o1 o0.039 o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) (19) (0.748) FD-L10 Vacuumresistant FX-100 series 2-o1 o0.039 Retroreflective Type FX-500 series 13 0.512 Lens (PMMA) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) 1.5 0.059 o1.6 o0.063 0.5 0.020 Convergent Reflective Type Others 2,000 78.740 2.5 0.098 3 8 2-o 0.11 o (o2) (o0.079) Model No. tube (m-PPE) Mounting holes for M2 countersunk head screw 2-o1 o0.039 Beam axis 2 0.079 Small Spot 14 0.551 1,000 39.370 2.5 0.098 (30) (5) (0.197) (1.181) 18 0.709 Enclosure (PC) Prism (PC) Flat Type Reflective Type o0.75 o0.030 fiber core x 1 (PMMA) 2,000 78.740 3.5 Sheath o1.3 o0.051 (Polyethylene) 0.138 o1.3 o0.051 o1 o0.039 Beam-receiving side (7) (0.276) Beam-emitting side o0.5 o0.020 x 1 fiber core (Acrylic) Sheath o1 o0.039 (Polyethylene) 0.6 2.9 0.024 0.114 2-mounting holes for M3 countersunk head screw Enclosure (PC) 3 0.118 Beam (1.15) (0.045) axis 2-mounting holes for M3 countersunk head screw 1.5 0.059 Sleeve Semi-custom fibers 19 0.748 7 0.276 2 0.079 Lens (PMMA) (1.15) (0.045) 0.5 0.020 Cylindrical Type Fiber Options Free-cut Square Head Type Chemical / Oilresistant o0.75 o0.030 fiber core x 1 (PMMA) 2,000 78.740 Sheath o1.3 o0.051 (Polyethylene) 3.5 0.138 o1.3 o0.051 o1 o0.039 Beam-receiving side (7) (0.276) Beam-emitting side o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) FD-L12W Threaded Type Wide Beam FD-L11 Enclosure (PC) Narrow Beam Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers Fibers Super Quality Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. 29 1.142 6.5 18 0.709 0.256 3,000 118.110 (2.1) (0.083) Beam-emitting side FD-L11 23.5 0.925 2-o2.2 o0.087 (19.4) (0.764) FD-L21W 2-mounting holes for M3 countersunk head screw 4.5 0.177 Beam axis Enclosure (ABS) Beam-receiving side o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) o0.25 o0.010 fiber core x 16 (PMMA) Sheath o2.2 o0.087 (Polyethylene) (2.3) (0.091) 63 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-L32H Free-cut 25 0.984 (8) (0.315) Lens (Norbornene resin) 15 0.591 15 0.591 Cap [Stainless steel (SUS304-CSP)] (o2) (o0.079) Model No. tube (m-PPE) 8 0.315 M3 x 0.5 0.020 2,000 78.740 Beam-emitting side Beam-receiving side o1.3 o0.051 3.5 0.138 Sheath o1.3 o0.051 (Polyethylene) 11.3 0.445 12.5 0.492 Sheath o1 o0.039 (Polyethylene) Hexagon nut M3 [Stainless steel (SUS304)] Threaded Type 2.1 0.083 FD-R33EG FD-R33EG outline drawing Cap [Stainless steel (SUS304-CSP)] 500 19.685 1.7 0.067 (o3) (o0.118) Model No. tube (m-PPE) (30) (1.181) (1) (0.039) 6 10.7 0.236 0.421 Protective tube o1.6 o0.063 (Polyolefin) Enclosure [ZDC2 (Nickel plated)] Toothed lock washer M3 [Stainless steel (SUS304)] Hexagon nut M3 [Stainless steel (SUS304)] 1.8 0.071 o2.3 o0.091 4.5 5.1 0.177 0.201 o2.2 o0.087 o6.5 5.5 o0.256 0.217 11.6 0.457 Cap [Stainless steel (SUS304-CSP)] 500 19.685 1.7 0.067 (o3) (o0.118) Model No. tube (m-PPE) (1) (0.039) 6 (30) 0.236 (1.181) 7 11 0.433 0.276 FD-R41 Toothed lock washer M3 [Stainless steel (SUS304)] Hexagon nut M3 Resin plug (ABS) [Stainless steel (SUS304)] Beam3.8 0.150 receiving side o6.5 5.5 Beamo0.256 0.217 emitting side 7 2.1 0.083 11.6 0.457 11 0.433 0.276 Beamreceiving side Beamemitting side Free-cut FD-R60 Free-cut FD-L32H Complete thread 6.5 0.256 or more 7 9 0.276 0.354 2 5.2 0.079 0.205 2.4 0.094 3.5 0.138 25 0.984 20 0.787 2,000 78.740 2,000 78.740 (o2.5) (o0.098) Model No. tube (m-PPE) Enclosure [ZDC2 (Nickel plated)] o3 o0.118 Toothed lock washer M4 [Stainless steel (SUS304)] Hexagon nut M4 [Stainless steel (SUS304)] o1.3 o0.051 4.2 0.165 o8.5 o0.335 7 0.276 o0.75 o0.030 fiber core x 1 (Acrylic) Sheath o1.3 o0.051 (Polyethylene) FD-R61Y Free-cut M6 x 0.75 0.030 2 0.079 o4.5 o0.177 Hexagon nut M6 [Stainless steel (SUS304)] o1.2 o0.047 (30) Fixing bracket (1.181) [Stainless steel (SUS303)] (o3.2) (o0.126) Model No. tube (m-PPE) R51 o5 o0.197 R0.1970.039 -0.1 -0.004 2 0.079 o6 o0.236-0.13 -0.005 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) o1.2 o0.047 Stainless steel pipe 905 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)] 5 0.197 Mounting reference surface (Screw periphery) o11 o0.433 10 0.394 11 0.433 5 0.197 2,000 78.740 2-o2.2 o0.087 5.5 0.217 8 0.315 Hexagon nut M6 [stainless steel (SUS304)] 2 0.079 M6 x 0.75 0.030 10 o11 o0.433 0.394 (Set screw tightening range) Details of sensing part 2-o2.2 o0.087 (30) (1.181) 8 0.315 Chemical / Oilresistant Heatresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Reflective Type 5.1 0.201 Others o1 o0.039 (o2.5) (o0.098) 4.5 0.177 1,000 39.370 6 10.7 (1) (0.039) 0.236 0.421 (3.1) (0.122) Head [stainless steel (SUS304)] Toothed lock washer M6 [stainless steel (SUS304)] Retroreflective Type Retroreflective Type o1 o0.039 o1.5 o0.059 2 0.079 Wide Beam Convergent Reflective Type Thru-beam Type FD-S21 Cap [stainless steel (SUS304-CSP)] Narrow Beam Fiber Dimensions 10 0.394 7 mm 0.276 in or more (complete thread) Small Spot 5 0.197 Toothed lock 13 washer M6 0.512 [Stainless steel (SUS304)] 4 0.157 Flat Type Vacuumresistant 2-o2.2 o0.087 (30) (1.181) M4 x 0.7 0.028 3 0.118 Cap [Stainless steel (SUS304-CSP)] 7 0.276 10 0.394 4.5 5.1 0.177 0.201 o2.2 o0.087 Protective tube o1.2 o0.047 (Polyolefin) Enclosure [ZDC2 (Nickel plated)] 11.3 0.445 1.8 0.071 12.5 0.492 Cylindrical Type Sleeve 10.7 0.421 o2.3 o0.091 3.8 0.150 2.1 0.083 Square Head Type Complete thread 10.8 0.425 or more 5.5 8 0.217 0.315 3.7 0.146 M3 x 0.5 0.020 3.5 0.138 Resin plug (ABS) Fibers Super Quality o6.5 5.5 o0.256 0.217 3-o3.2 o0.126 (0.5 0.020 deep, on both sides) Complete thread 10.8 0.425 or more 5.5 8 0.217 0.315 3.7 0.146 M3 x 3.5 0.138 0.5 0.020 11.3 0.445 12.5 0.492 How to read Model No. Toothed lock washer M3 [Stainless steel (SUS304)] 3.8 0.150 FD-R32EG, FD-R32EG outlineFD-R34EG drawing Choose by shape/ application Earlier models comparison table Enclosure [ZDC2 (Nickel plated)] 2-o3.2 o0.126 mounting holes, o5.7 o0.224 spot facing, 2.6 0.102 deep Fiber Selection Guide Model o1 o0.039 (30) (1.181) 1.7 0.067 1.8 0.071 o2.3 o0.091 o1.5 o0.059 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) Enclosure (ABS) 7.5 0.295 7.3 0.287 5.5 0.217 3.7 0.146 2-o2.2 o0.087 (16.7) (0.657) Tough Fiber Free-cut FD-R31G outline drawing Complete thread 10.8 0.425 or more 4,000 157.480 4.5 0.177 30 1.181 6.5 0.256 FD-R31G New product introduction Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] 7 11 11.6 0.276 0.433 0.457 Resin plug (ABS) (o2.5) (o0.098) Model No. tube (m-PPE) Amplifiers FX-500 series FX-100 series INDEX o1.0 o0.039 fiber core x 1 (PMMA) Outer sheath o2.2 o0.087 [PFA (Fluorine resin)] Inner sheath o1.8 o0.071 (Polyethylene) o0.25 o0.010 fiber core x 2 (PMMA) (each beam-emitting part and beam-receiving part) 64 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-S30 FD-S31 2 0.079 2,000 78.740 Resin plug (ABS) (20) (0.787) 8 0.315 4 Set screw tightening range 0.157 o2 o0.079 2 0.079 8 0.315 (19.7) (0.776) 10.2 0.402 (0.3) (0.012) o2.2 o0.087 How to read Model No Earlier models comparison table o3 o0.118 -0.07 -0.003 -0.10 -0.004 Mounting reference surface (Periphery) (o4.33) (o0.170) o1 o0.039 (o2) (o0.079) Model No. tube (m-PPE) o1.8 o0.071 Super Quality Threaded Type Square Head Type o2 o0.079 o3 o0.118 -0.07 -0.003 -0.1 -0.004 Mounting reference surface (Periphery) FD-S32 Free-cut 2,000 78.740 o1 4 0.157 (Set screw tightening range) o0.039 (30) (1.181) (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 Fiber core x 1 (Acryic) Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] End bracket [Stainless steel (SUS303)] Fibers Free-cut FD-S32W Free-cut 2.7 0.106 2,000 78.740 (30) (1.181) 15 0.591 7 0.276 Cylindrical Type 2.7 0.106 15 0.591 2,000 78.740 (30) (1.181) 7 0.276 2-o1.3 o0.051 2-o1.3 o0.051 o3 o0.118 Sleeve o3 o0.118 End bracket [Stainless steel (SUS303)] Flat Type End bracket [Stainless steel (SUS303)] (o2.5) (o0.098) Model No. tube (m-PPE) o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) (o2.5) (o0.098) Model No. tube (m-PPE) o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) Small Spot Narrow Beam Wide Beam FD-S33GW Free-cut Convergent Reflective Type (30) (1.181) 16 0.630 Beam-emitting side o3 o0.118 End bracket [Stainless steel (SUS303)] Details of sensing part Beam-receiving side (o2) (o0.079) Model No. tube (m-PPE) Protective tube [PFA (Fluorine resin)] Semi-custom fibers 2-o1.3 o0.051 FD-S32W Cover [PFA (Fluorine resin)] Sheath o1 o0.039 (Polyethylene) Sheath o1.3 o0.051 (Polyethylene) o1.0 o0.039 fiber core x 1 (PMMA) Outer sheath o1.3 o0.051 (Polyethylene) 2.7 0.106 Fiber Options 2,000 78.740 1,500 59.055 o4 o0.157 o5.5 o0.217 o1.3 o0.051 Heatresistant Liquid Leak / Liquid Detection o1 o0.039 Chemical / Oilresistant Vacuumresistant Free-cut 2,000 78.740 15 0.591 7 0.276 Retroreflective Type FD-S60Y Beam-receiving o0.25 o0.010 fiber core x 9 (PMMA) FD-S32 Beam-emitting o0.5 o0.020 fiber core x 1 (PMMA) FD-V30 Free-cut FD-V30W Free-cut Fiber Dimensions 2.8 0.110 Thru-beam Type Beam axis 15 0.591 Retroreflective Type A Reflective Type Others Amplifiers FX-500 series o1.5 o0.059 10 0.394 Set screw tightening range 15 0.591 o3 o0.118 Sleeve [Stainless steel (SUS303)] End bracket [Stainless steel (SUS303)] View A 2.8 0.110 Beam axis 15 0.591 2,000 78.740 2-o1 o0.039 (30) (1.181) A (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) End bracket [Stainless steel (SUS303)] 2 0.079 2.5 0.098 1.3 0.051 1.3 0.051 Shielding plate (Polyester) FX-100 series INDEX FD-S33GW 2,000 78.740 2-o1 o0.039 (30) (1.181) o3 o0.118 View A 2 0.079 2.5 0.098 Set screw tightening range 15 0.591 o1.5 o0.059 Sleeve [Stainless steel (SUS304)] 10 0.394 Shielding plate (Polyester) (o2) (o0.079) Model No. tube (m-PPE) o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) 65 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Dimensions are listed in the order of thru-beam type, retroreflective type, and reflective type, and in alphabetic order of the Model No. Reflective type fibers FD-V50 Free-cut FD-Z20HBW 10 0.394 0.5 0.020 1.05 0.041 Beam axis 15 0.591 20 0.787 A 2,000 78.740 2-o2.2 o0.087 (30) (1.181) 5 0.197 End bracket [Stainless steel (SUS303)] View A 2 0.079 3.5 0.138 2.5 0.098 2.2 0.087 10 4 0.157 0.394 1,000 39.370 o2.2 o0.087 hole, o3.6 o0.142 spot facing, 1.4 0.055 deep 2-o1 4-R1 R0.039 (30) o0.039 (1.181) Beam axis (o3.2) (o0.126) Model No. tube (m-PPE) Choose by shape/ application Super Quality Threaded Type Square Head Type Shielding plate (Polyester) Cylindrical Type FD-Z20W Free-cut FD-Z40HBW Free-cut 7 0.276 3.5 0.138 1.2 0.047 2.5 0.098 10 0.394 4 0.157 5 0.197 o3.2 o0.126 hole, o5.6 o0.220 spot facing, 2.2 0.087 deep 1 3.5 0.138 0.039 1.05 0.041 1,000 39.370 o2.2 o0.087 hole, o3.6 o0.142 spot facing, 1.4 0.055 deep 4-R1 R0.039 2-o1 (30) (1.181) o0.039 Beam axis 11 0.433 2.2 0.087 14 6.5 0.256 0.551 (o2) (o0.079) Model No. tube (m-PPE) Inner pipe [Stainless steel (SUS304)] Enclosure (PC) 1.05 0.041 FD-Z20HBW o2.4 o0.094 Inner pipe [Stainless steel (SUS304)] Beam axis 0.9 0.035 o0.5 o0.020 fiber core x 1 (PMMA) Sheath o1 o0.039 (Polyethylene) FD-Z40W Free-cut 1 0.039 7 0.276 7 0.276 2.2 o2.4 o0.094 0.087 Prism (PMMA) Beam axis FD-Z50HW Free-cut 15 0.591 Lens (BK7) 1 0.039 Retroreflective Type Chemical / Oilresistant Enclosure (PC) 5.2 0.205 Beam axis Vacuumresistant Liquid Leak / Liquid Detection 2,000 78.740 4.6 0.181 9.5 0.374 2-o2.2 o0.087 o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) Fiber Options Semi-custom fibers Assembly dimensions with MS-FD-2 (attached mounting bracket) Lens (BK7) o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 9.5 0.374 4.6 0.181 12.2 0.480 5 0.197 10.2 0.402 1.2 0.047 1 0.039 15 2,000 78.740 0.591 2-M3 x 0.5 0.020 6 0.236 Beam axis 14 0.551 Retroreflective Type 3.3 0.130 4 0.157 7 0.276 5.2 0.205 Fiber Dimensions Thru-beam Type 4 0.157 3.3 0.130 FD-V50 Convergent Reflective Type Heatresistant 2,000 78.740 o3.2 o0.126 hole, o5.8 o0.228 spot facing, 2.2 0.078 deep 4-R1 R0.039 2-o1.3 (30) (1.181) o0.051 (o2.5) (o0.098) Model No. tube (m-PPE) Inner pipe [Stainless steel (SUS304)] Enclosure (PC) 1.05 0.041 Wide Beam o1 o0.039 fiber core x 1 (PMMA) Sheath o1.3 o0.051 (Polyethylene) 3.5 0.138 1.2 0.047 3.5 0.138 3.5 0.138 14 6.5 0.051 0.256 Flat Type Narrow Beam 2-o1.3 o0.051 (o2.5) (o0.098) Model 2.7 0.106 No. tube (m-PPE) 1.6 0.063 7 0.276 Sleeve Small Spot 2,000 78.740 3.5 4-R1 R0.039 0.138 Enclosure (PC) (30) (2.2) (0.087) (1.181) 3.5 0.138 7 0.276 2.2 0.087 Prism (PMMA) o1.5 o0.059 Earlier models comparison table Fibers o0.75 o0.030 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) 1.7 0.067 2 0.079 How to read Model No. o0.5 o0.020 fiber core x 1 (PMMA) 0.6 0.024 Sheath o1 o0.039 (Polyethylene) 2.3 0.091 3 0.118 0.5 0.020 Fiber Selection Guide Model (2.2) (0.087) (o2) (o0.079) Model No. tube (m-PPE) Inner pipe o1.5 [Stainless steel (SUS304)] Enclosure (PC) o0.059 7 1 0.039 2.1 0.083 0.276 o5 o0.197 o2 o0.079 Sleeve [Stainless steel (SUS304)] Set screw tightening range 10 0.394 Tough Fiber Free-cut 4.5 0.177 New product introduction MS-FD-2 Mounting bracket [Stainless steel(SUS304)] Enclosure (PC) 2-o2.2 o0.087 Reflective Type Others FD-Z40HBW o1 o0.039 fiber core x 1 (PMMA) Sheath o2.2 o0.087 (Polyethylene) Amplifiers FR-Z50W FX-500 series FX-100 series INDEX 66 DIMENSIONS (Unit: mm in) New product introduction Tough Fiber Fiber Selection Guide Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Vacuum-resistant Atmospheric side fiber FT-J8 Free-cut (Accessory for vacuum-resistant fiber) Photo-terminal side Model Choose by shape/ application 4 0.157 How to read Model No 10 0.394 o3.6 o0.142 o2.2 o0.087 11 0.433 Mounting cap nut opposing faces 8 0.315 [Stainless steel (SUS)] o4 o0.157 Earlier models comparison table Amplifier side 2,000 78.740 Joint [Brass (C3604) (Nickel plated)] Fibers Super Quality Threaded Type Square Head Type FB-1 Fiber bender (Optional) Cylindrical Type Flat Type Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection o4.5 o0.177 spiral tube [Stainless steel (SUS)] Material: PP (Containing steel blade) 36 1.417 6 0.236 2 0.079 Mounting hole Chamber wall or flange o5.5 to o6.0 o0.217 to o0.236 M5 x 0.8 0.031 thread [Stainless steel (SUS)] Others Amplifiers FX-500 series FX-100 series INDEX 14 0.551 3.7 0.146 M2.6 x 0.45 0.018 internal thread, 3 0.118 deep FDP- Vacuum-resistant side-view lens (Optional) 10.5 0.413 L 15 0.591 3 0.118 15 0.591 o7 o0.276 spiral tube [Stainless steel (SUS)] o8 o0.315 [Brass (Nickel plated)] M6 x 0.75 0.030 internal thread, 5 0.197 deep Heat resistant adhesive 9.5 0.374 7.3 0.287 3.6 0.142 4.5 0.177 2-o3.1 o0.122 2.8 0.110 6.6 0.260 o1 o0.039 vent hole 5.5 0.217 3.6 0.142 o18 o0.709 M2.6 x 0.45 0.018, 3.2 0.126 deep M10 x 1 0.039 thread [Brass (Nickel plated)] *Length L FTP-500, FTP-N500, FDP-N500, FDP-500 Enclosure [Stainless steel (SUS)] o11 o0.433 M6 x 0.75 0.030 thread [Stainless steel (SUS)] Model No. Material: Enclosure........Aluminum alloy (A6061-T6) Lens...............BK-7 4.7 0.185 15 0.591 3.7 0.146 o4 o0.157 Lens (BK7) 2 0.079 M3 x 0.5 0.020 internal thread, 5 0.197 deep Vacuum-resistant expansion lens (Optional) 9.2 0.362 6 0.236 4 0.157 L 15 0.591 o3.8 o0.150 spiral tube [Stainless steel (SUS)] o5 o0.197 [Brass (Nickel plated)] M5 x 0.8 0.031 thread O-ring Spring washer o10 o0.394 Opposing faces 8 0.315, thickness 3 0.118 o3.6 o0.142 lens o1 o0.039 vent hole Reflective Type 5 0.197 M4 x 0.7 0.028 internal thread, 5 0.197 deep FTP-N Hole FV-SV2 M8 x 1 0.039 thread [Brass (Nickel plated)] o6 o0.236 [Brass (Nickel plated)] FV-BR1 Photo-terminal (for vacuum-resistant) (with vacuum-resistant fiber) Semi-custom fibers Retroreflective Type o15 o0.591 8.6 0.341 Fiber Options Thru-beam Type 15 0.591 3 0.118 20 0.787 FV-LE1 Fiber Dimensions L 15 0.591 Small Spot Narrow Beam Protective tube (Optional) FTP-, FDP-N 52 2.047 40 1.575 Sleeve FTP-FDP- Length L 500 +100 19.685 +0.394 0 FTP-1000, FTP-N1000, FDP-N1000, FDP-1000 1,000 +100 39.370 +0.394 0 FTP-1500, FTP-N1500, FDP-N1500, FDP-1500 1,500 +100 59.055 +0.394 0 67 DIMENSIONS (Unit: mm in) Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. FX-AT2 Attachment for fixed-length fiber (Accessory for fixed-length fiber) Attachment for o2.2 mm o0.087 in fiber 9.1 0.358 7.5 0.295 2-o2.3 o0.091 8.2 0.323 Fiber Selection Guide Model Choose by shape/ application 11.2 16 0.441 0.630 7 0.276 7 0.276 5 0.197 4 0.157 14 0.551 7 13 0.276 0.512 Tough Fiber (Accessory for o2.2 mm o0.087 in fiber) 8 0.315 6 0.236 Material: POM FX-AT3 New product introduction How to read Model No. Material: Polycarbonate Earlier models comparison table FX-AT4 Attachment for o1 mm o0.039 in fiber FX-AT5 Attachment for o1.3 mm o0.051 in fiber (Accessory for o1 mm o0.039 in fiber) 20.5 0.807 3 0.118 4 0.157 3.5 0.138 6.5 2 0.256 0.079 o2.2 o0.087 (Accessory for o1 mm o0.039 in / o1.3 mm o0.051 in mixed fiber) 3 0.118 4 0.157 3.5 0.138 2 0.079 o2.2 o0.087 6.5 0.256 5 0.197 15 7 0.591 0.276 5 0.197 1.7 0.067 o2.2 o0.087 Material: H older..............PA (Nylon 66) Ground.............POM 3.5 0.138 2 0.079 o2.2 o0.087 FX-CT2 o4 o0.157 9.2 0.362 o4.3 o0.169 Material: Enclosure............ Brass (Nickel plated) Lens.................... Glass 15 7 0.591 0.276 5 0.197 1.7 0.067 o2.2 o0.087 Threaded Type Square Head Type Cylindrical Type Sleeve Fiber cutter (Accessory for free-cut type fiber) o1.4 o0.055 Small Spot Narrow Beam Wide Beam 8 0.315 45 1.772 o1.1 o0.043 Super Quality Flat Type Convergent Reflective Type Retroreflective Type 25 0.984 Chemical / Oilresistant Heatresistant Material: ABS FX-LE2 Super-expansion lens (Optional) 22.2 0.874 17 0.669 8 5 0.315 0.197 Lens Knurled surface o9 o0.354 6 0.236 o7 o0.276 o12 o10.2 o0.472 o0.402 M2.6 x 0.45 0.018 internal thread, 3 0.118 deep FX-MR1 Pinpoint spot lens (Optional) Lens Lens Effective dia.: o3.3 o0.130 Semi-custom fibers M4 x 0.7 0.028 internal thread, 6 0.236 deep = 36 to 37 1.417 to 1.457 Note: In order to obtain a o0.5 mm o0.02 in spot, it is necessary to keep M4 x 0.7 0.028 internal " ", in the above figure, within the thread, 6 0.236 deep specified range. Material: Enclosure............ Aluminum (Black ALMITE) Lens.................... Glass Fiber Dimensions FX-MR2 Zoom lens (Optional) 27.1 1.067 20 0.787 Mounting drawing with FD-42G Liquid Leak / Liquid Detection Fiber Options Material: Enclosure............ Stainless steel (SUS303) Lens.................... Glass o6 o0.236 o1.4 o0.055 14.6 0.575 Expansion lens (Optional) 20.2 0.795 11 0.433 o1.4 o0.055 Fibers Vacuumresistant FX-LE1 o4 o0.157 6.5 0.256 5 0.197 Material: Holder..............PA (Nylon 66) Ground.............POM FX-AT6 Attachment for o1 mm o0.039 in / o1.3 mm o0.051 in mixed fiber 20.5 0.807 3 0.118 4 0.157 o1.1 o0.043 o1.1 o0.043 5 0.197 7 15 0.591 0.276 5 0.197 1.7 0.067 o2.2 o0.087 Material: Holder.....PA (Nylon 66) Ground...POM (Accessory for o1.3 mm o0.051 in fiber) 20.5 0.807 4.5 0.177 Thru-beam Type Retroreflective Type Reflective Type 7 0.276 Others o8 o0.315 o7.1 o0.280 M4 x 0.7 0.028 internal thread, 6 0.236 deep Material: Enclosure............ Aluminum (Black ALMITE) Lens.................... Glass Amplifiers FX-500 series FX-100 series INDEX 68 New product introduction Tough Fiber DIMENSIONS (Unit: mm in) FX-MR3 Finest spot lens (Optional) FX-MR5 Model 15 0.591 Choose by shape/ application o4 o0.157 10.3 0.406 20.3 0.799 8 0.315 3 0.118 2.5 0.098 4.5 0.177 M3 x 0.5 0.020 internal thread Earlier models comparison table o5 o0.197 lens 3.3 0.130 = 27.5 1.083 4 0.157 5 0.197 Zoom lens (Optional) 6.3 0.248 Mounting drawing with FD-EG30 Fiber Selection Guide How to read Model No Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. Knurled Material: E nclosure............ Aluminum (Black ALMITE) Lens.................... Glass Note: When inserting the fiber, insert fully till it stops. Material: Enclosure............ PBT (Black) Lens.................... Glass Fibers 2-M3 x 0.5 0.020 thru-hole threads 7 0.276 M4 x 0.7 0.028 internal thread, 11 0.433 deep 3.15 0.124 NT-FX-MR5 (exclusive nut) is attached. Super Quality Threaded Type FX-MR6 Finest spot lens (Optional) Square Head Type Mounting drawing with FD-EG31 Cylindrical Type Caulking part 15.3 0.602 Lens Flat knurl M3 x 0.5 0.020 o4 o0.157 16 0.630 Wide Beam Holder [Stainless steel Lens (Acrylic) (SUS303)] o5 o0.197 Narrow Beam M3x0.5 0.020 o5 o0.197 o4.3 o0.169 = 28.5 1.122 Small Spot Convergent Reflective Type Finest spot lens (Optional) 5 0.197 Sleeve Flat Type FX-MR7 5 0.197 Laurette of straight pattern Mounting drawing with FD-R31G/R32EG/R33EG/R34EG 27.8 1.094 Material: Enclosure............ Aluminum (Black ALMITE) Lens.................... Acrylic Note: When inserting the fiber, insert fully till it stops. Retroreflective Type Chemical / Oilresistant Heatresistant FX-MR8 Vacuumresistant Zoom lens (Optional) Caulking part Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Lens (BK7) Holder [Stainless steel (SUS303)] M3x0.5 0.020 o4.3 o0.169 o5 o0.197 Laurette of straight pattern Mounting drawing with FD-R31G/R32EG/R33EG/R34EG 22.8to27.5 0.898 to 1.083 Parallel light lens (Optional) Caulking part 15 0.591 5 0.197 o4.3 o0.169 FX-MR9 Lens (BK7) Holder [Stainless steel (SUS303)] 10 0.394 5 0.197 M3x0.5 0.020 o5 o0.197 Laurette of straight pattern Mounting drawing with FD-R31G/R32EG/R33EG/R34EG 22.5 0.886 69 Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) FX-SV1 Side-view lens (Optional) MS-EX3 0.5 0.020 o4 o0.157 Rod prism 12.2 0.480 10.2 0.402 4.9 0.193 Anti-slip rubber sheet (8 x 9.5 x 1) (0.315 x 0.374 x 0.039) 5 0.197 6 0.236 t1.2 10 0.394 M2.6 x 0.45 0.018 internal thread, 3 0.118 deep 16 0.630 23 0.906 Material: Enclosure............ Brass (Nickel plated) Lens.................... Glass MS-FD-3 Fiber mounting bracket 3.3 0.130 C1 C0.039 RF-003 R2.5 R0.098 (2-R) 7 0.276 Cover [Stainless steel (SUS304)] (88) (90) 6.9 0.272 How to read Model No. Earlier models comparison table 14 0.551 10 0.394 19 28 (Effective reflector width) 0.748 1.102 1 0.039 3.2 0.126 4.3 0.169 Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Flat Type Reflector (Norbornene resin) Small Spot Narrow Beam 3.5 0.138 0.4 0.016 Choose by shape/ application Sleeve 3.9 0.154 (88) (90) 3.3 0.130 10 0.394 (Effective reflector width) (2-R) 1.1 0.043 19 0.748 3.2 0.126 R1.6 R0.063 10.6 0.417 Fiber Selection Guide Model 4 0.157 Reflector for FR-KZ50E/KZ50H 10.1 5 0.398 0.197 5 0.197 10 0.394 3.3 0.130 Accessory for FR-KZ50E/KZ50H 3.3 0.130 3-R0.5 R0.020 5 0.197 4 0.157 Material: Stainless steel (SUS304) Material: Brass (Nickel plated) Accessory for FT-KV40/FT-KV40W (11) (0.433) 3.2 0.126 Tough Fiber 2-M3 x 0.5 0.020 9.8 0.386 0.8 8.5 0.031 0.335 2-o3.5 o0.138 mounting holes Fiber mounting bracket Accessory for FD-Z50HW, FR-KZ50E/KZ50H/Z50HW, FD-H30-KZ1V-S 4 0.157 8.7 0.343 Knurled surface 8 0.315 2.5 0.098 MS-FD-2 Mounting bracket for FX-MR2 (Accessory for FX-MR2) New product introduction 6.9 0.272 Wide Beam Convergent Reflective Type Material: Stainless steel (SUS304) Retroreflective Type RF-13 Reflective tape for FR-Z50HW RF-210 Reflector (Optional) Accessory for FR-Z50HW Vacuumresistant 12.8 0.504 30 1.181 Rear surface (Pressure-sensitive adhesive) Heatresistant 33.3 1.311 30 1.181 0.5 0.020 11 0.433 Reflective surface (Acrylic) Material : Acrylic (Reflective surface) Liquid Leak / Liquid Detection M3 nut mounting holes (for mounting at the back) Reflector Base 3.2 0.126 25 0.984 10 0.394 2-o3.4 o0.134 thru-holes (for mounting at the side) 2-o3.4 o0.134 holes, 6 0.236 deep (for mounting at the back) 2-M3 nut mounting holes (for mounting at the side) Material: A crylic (Reflector) ABS (Base) Two M3 (length 8 mm 0.315 in) screws with washers and two nuts are attached. RF-220 Reflector (Optional) RF-230 35.3 1.390 34.3 42.3 1.350 1.665 8 0.315 Reflector (Optional) 50.3 1.980 25 0.984 Material: Acrylic (Reflector) ABS (Base) 2-o3.6 o0.142 mounting holes Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type FX-500 series (30) (1.181) 8.3 0.327 Semi-custom fibers Amplifiers 4 0.157 3.3 0.130 Fiber Options Others 49.3 59.3 1.941 2.335 (21) (0.827) Chemical / Oilresistant 10 0.394 FX-100 series 5 0.197 40 1.575 Material: Acrylic (Reflector) ABS (Base) 3.3 0.130 2-o4.6 o0.181 mounting holes 8.3 0.327 INDEX 70 New product introduction Tough Fiber Fiber Selection Guide Digital Fiber Sensor FX-500 SERIES Ver.2 At the industry's leading edge Model Choose by shape/ application How to read Model No Conforming to EMC Directive Ver.2 Listing Earlier models comparison table Certified Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type PNP output type available Timer Automatic sensitivity setting Test input Interference Light intensity monitor prevention * There is no change in Model No. and price due to version upgrade. * Cover opened state is shown. Improved the operability and visibility of the operation keys External sync. Operation keys (setting switch and MODE key) have been renewed to be easy to operate. Also, the color of the keys has been changed from black to light gray to achieve good visibility in dim light. Upgraded (Ver. 2) Retroreflective Type Previous Chemical / Oilresistant Setting switch MODE key Setting switch MODE key Heatresistant Clicking touch! Vacuumresistant Liquid Leak / Liquid Detection Fiber Options High stability! Semi-custom fibers Fiber Dimensions Thru-beam Type When the FX-500 series is used together with our super quality fiber, the incident light intensity variation among units is decreased to only 1/4 of that of conventional models. By being close to absolute values instead of modified digital values, changes in detection that could not be found in the past can now be monitored. Super quality fiber FX-500 series Retroreflective Type Incident light intensities are stable. Threshold Incident light value intensity Reflective Type Others Incident light intensity 1/4 Unify the threshold value Can control by using just one threshold value. incident light intensity variation [from previous] Amplifiers FX-500 series FX-100 series Previous amplifier Variation in the threshold value Threshold Incident light value intensity Incident light intensity L D MODE L D MODE L INDEX D MODE L MODE D Large variation in incident light intensity. Requires setting different threshold values for each sensor. 71 A quality that surpassed that of standard fibers! New fibers developed using a new manufacturing method adopted by our own factory along with a persistent quality control system. The basic performance of a standard fiber is greatly enhanced! New product introduction Tough Fiber Fiber Selection Guide Model Variation in emission amount of the fiber core is controlled down to less than 10 %, achieving a stable detection. * Beam axis deviation: Thru-beam type within 2 , Reflective type within 3 * Beam axis centering precison: within 150 m Expanded temperature range Ambient temperature [-40 to +70 C -40 to +158 F in previous model] - 55 to +80 C - 67 to +176 F 1.2 times more than previous model Choose by shape/ application o2.2 mm o0.087 in standard fiber How to read Model No. Previous Stable emission amount New material 10 Single core standard fiber with high flexibility Earlier models comparison table In general, high-flexibility types adopt a multi-fiber core, which may result in large variation in light emission. Fibers R4 More flexible! Super Quality Threaded Type Bending radius [Previous model is R25 mm R0.984 in] R4 mm R0.157in Square Head Type 1/6 of that of previous model Cylindrical Type Sleeve Integrated high-precision plug The centering precision of the fiber core attached to the inserting plug is doubled. As the insertion precision is increased, the variation among units can be greatly suppressed. * Centering precision: within 40 m More bendable! Flat Type Small Spot Bending durability [Previous model is 1,000 times] 10 million times Narrow Beam 10,000 times more than previous model Wide Beam * Bending conditons Bending radius: R10 mm R 0.394 in, Reciprocating bending 180 Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant H y p e r Max. 25 s response time HYPR mode incorporated FX-500 with its high response time contributes to improve productivity. FX-500 in combination with small diameter fibers which can handle challenging detections, allows long sensing range. 7RXJK FX-500 FD-41 Previous FD-NFM2 Max. Vacuumresistant 5.7 times! (Note) longer than the previous model Liquid Leak / Liquid Detection Fiber Options HYPR mode FX-301 (LONG mode) Performing minute object detection when using a small diameter fiber is now possible with a high response time and longer sensing range. Semi-custom fibers Note: When using FD-NFM2. Fiber Dimensions Thru-beam Type So accurate! Sharp detection with suppressed hysteresis FX-500 with its accurate detection catches fractional differences in light intensity, achieving high precision and solving low-hysteresis applications. * Long range detection of small objects with small difference in light intensity H-02 mode Retroreflective Type * Highly accurate detection while avoiding saturation H-01 mode Reflective Type Others Amplifiers FX-500 series FX-100 series Retroreflective FR-Z50HW type fiber FT-A11 Reflector INDEX 72 New product introduction Tough Fiber Flat display with wide viewing angle The large and high-contrast 7-segment display of high luminance provides clear visibility from a wide angle of view. Pr ev i ou s sp ac e re qu Fiber Selection Guide i re 1/3 nt Reduced to Choose by shape/ application me Compact cover does not get in the way Model of the previous model's size Clearly visible even from sideways How to read Model No Earlier models comparison table R23 mm R0.906 in Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Resolves variation in displayed incident light intensity Display adjustment setting The variation in display can be adjusted to random values. This helps to define proper instruction in a work order. Current incident light intensity Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Display adjustment setting Unify incident light intensity into any value Stable detection over long and short periods Saves maintenance time The "four-chemical emitting element", which we are the first to incorporate to maintain a stable level of light emission, has now become an industry standard. FX-500 series continues to adopt the same emitting element as well as the "APC (Auto Power Control) circuit" which improves stability in short periods such as when the power is turned on. This function performs automatic setting to threshold value by checking the incident light intensity at desired intervals in order to follow the changes in the light amount resulting from changes in the environment over long periods (such as dust). This contributes to reduction in maintenance hours. Suitable for preventative maintenance FX-502(P) FX-505(P)-C2 Self-diagnosis output Detect deterioration in light intensity (e.g. Useful in dusty environment) Stabilized emission amount FX-502(P) / 505(P)-C2 can set Output 2 as a selfdiagnosis output. When the teaching of Output 1's threshold value is carried out, Output 2 is set concurrently with the setting randomly shifted by the amount of surplus of threshold value. Light intensity deterioration due to fiber breakage or dust accumulation can be notified as an alarm output. Threshold tracking function Self-diagnosis can be used with the threshold tracking function for added effectiveness. Stable detection while being eco-friendly Emission power & gain setting In cases when the incident light intensity is saturated, the light emitting amount can be adjusted to the optimal level by AUTO without changing the response time. This allows stable detection with an optimal S/N ratio and saves energy by controlling the emitting electric current. Detecting a transparent sheet AUTO Normal Object present Object absent Saturated Auto mode (AUTO) and 3-level manual mode (H / M / L [fine-adjustable]) are incorporated. 73 Built-in logic functions New product introduction No PLC necessary, saving material and programming costs Logical calculation functions 3 logical calculations (AND, OR, XOR) are available with fiber sensor only. 3 logical operations can be selected against Output 1. Additional controller is not required so both wire-saving and cost reduction can be achieved. Calculation of two neighboring amplifiers Lower side Output 1 Calculation result output Upper side Output 1 Normal operation Equipped with 5 timer types A wide variety of timer control operations can be carried out by fiber sensors only. Time chart Communication direction (Up to 12 units) Calculation of two outputs in one amplifier Set to L-ON Sensing condition FX-502(P) / 505(P)-C2 T1 ON-delay Detection fiber Output 1 Calculation result output One-shot FX-502(P) / 505(P)-C2 External input (sensor, contact, PLC, etc.) Synchronization fiber Output 1 Calculation result output T1 OFF-delay Output 2 Normal output operation Calculation of one amplifier and external input Beamreceived Beaminterrupted ON OFF T1 T1 ON OFF T1 ON/OFF -delay T1 ON-delay/ One-shot T1 ON OFF T2 T2 ON OFF ON OFF Timer period: 0.05 ms to 32 s Output 1 has ON / OFF-delay and ON-delay / One-shot timers are available. Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Analog output cable type FX-505(P)-C2 To monitor the sensing of objects, a 4 to 20 mA analog current is output in respond to the digital value of the incident light intensity. Edge tracking of film or sheet 20 Output current (mA) Actual position Drift position Incident light intensity (digit) Cylindrical Type The number of data banks used for saving the setup conditions of the amplifirer is increased to eight. Setup conditions can be saved and loaded to make setup changes easy at a worksite where multiple models are manufactured. Sleeve Remote control improves work FX-502(P) FX-505(P)-C2 efficiency by external input Work efficiency can be improved by operating via PLC output or other external signal. (FX-502(P) can operate via external signal when switching from Output 2 to external input.) 4 0 Smooth setup changes by 8 data banks 4,000/8,000 The drifting path can be monitored as the light intensity changes. Functions operable by external input Full-auto / Limit / 2-point teaching Display adjustment setting Data bank load / save Logical calculation (self-unit only) Emission halt Copying function lock (self-unit only) Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options An optical communication function allows sensors to be adjusted simultaneously The data that is currently set can be copied and saved all at once for all amplifiers connected together from the right side thanks to the optical communication function. This greatly reduces troublesome setup tasks and makes setup much smoother. No need to specify a main unit or sub unit All FX-500 amplifiers can be used as either a main unit or a sub unit. Just use a main cable or a sub cable to distinguish the two. This reduces the costs of inventory management. Semi-custom fibers Fiber Dimensions Thru-beam Type The same part number can be used as either a main unit or sub unit! Single copy & save operation for all amplifiers Retroreflective Type Reflective Type Others Sub cable Optical communication window Amplifiers FX-501 FX-502 FX-500 series Main cable (3-core) CN-73-C Sub cable (1-core) CN-71-C Main cable (4-core) CN-74-C Sub cable (2-core) CN-72-C FX-100 series Main cable Disconnection is possible without moving the amplifier sideways INDEX 74 Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Type Appearance Emitting element Model No. Standard type Fiber Selection Guide Amplifiers Quick-connection cable is not supplied with FX-501(P) and FX-502(P). Please order it separately. 2-output type Tough Fiber ORDER GUIDE Output FX-501 NPN open-collector transistor FX-501P PNP open-collector transistor NPN open-collector transistor 2 outputs Red LED FX-502P PNP open-collector transistor 2 outputs FX-505-C2 NPN open-collector transistor 2 outputs, analog output FX-505P-C2 PNP open-collector transistor 2 outputs, analog output Threaded Type Square Head Type Quick-connection cables Cylindrical Type For FX-501(P) Quick-connection cable is not supplied with the amplifier. Please order it separately. Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Type Main cable (3-core) Sub cable (1-core) Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers CN-73-C1 Description Incorporated (Switchable with Output 2) Incorporated Main cable *CN-73-C Length: 1 m 3.281 ft CN-73-C5 0.2 mm2 3-core cabtyre cable, with connector Length: 2 m 6.562 ft on one end Cable outer diameter: o3.3 mm o0.130 in Length: 5 m 16.404 ft CN-71-C1 Length: 1 m 3.281 ft CN-71-C2 Length: 2 m 6.562 ft CN-73-C2 CN-71-C5 Retroreflective Type Chemical / Oilresistant Model No. External input - FX-502 Cable type New product introduction 0.2 mm 1-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in Length: 5 m 16.404 ft Connectable to a main cable up to 15 cables. 2 Sub cable *CN-71-C For FX-502(P) Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Main cable (4-core) Model No. CN-74-C1 CN-74-C2 CN-74-C5 Sub cable (2-core) CN-72-C1 CN-72-C2 CN-72-C5 Description Main cable *CN-74-C Length: 1 m 3.281 ft 0.2 mm2 4-core cabtyre cable, with connector Length: 2 m 6.562 ft on one end Cable outer diameter: o3.3 mm o0.130 in Length: 5 m 16.404 ft Length: 1 m 3.281 ft 0.2 mm2 2-core cabtyre cable, with connector on one end Length: 2 m 6.562 ft Cable outer diameter: o3.3 mm o0.130 in Length: 5 m 16.404 ft Connectable to a main cable up to 15 cables. Sub cable *CN-72-C End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade. Fiber Dimensions Appearance Model No. Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX MS-DIN-E Description When amplifiers are mounted in cascade, or when an amplifier moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. Two pcs. per set 75 OPTIONS New product introduction Designation Model No. Amplifier mounting bracket MS-DIN-2 Description Mounting bracket for amplifier Amplifier mounting bracket Tough Fiber *MS-DIN-2 Fiber Selection Guide Model Accessory *FX-MB1 (Amplifier protection seal) 10 sets of 2 communication window seals and 1 connector seal Choose by shape/ application Communication window seal How to read Model No. Earlier models comparison table Connector seal Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 76 New product introduction SPECIFICATIONS Tough Fiber Model Choose by shape/ application How to read Model No Earlier models comparison table Model No. Fiber Selection Guide Type Item Standard type 2-output type Cable type (Analog output type) NPN output FX-501 FX-502 FX-505-C2 PNP output FX-501P FX-502P FX-505P-C2 +10 12 to 24 V DC-15 % Ripple P-P 10 % or less Supply voltage Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output of cable type) ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output of cable type) Output (2-output type and cable type: Output 1, Output 2) NPN open-collector transistor PNP open-collector transistor * Maximum sink current: 100 mA * Maximum source current: 100 mA (2-output type and cable type are 50 mA) (Note 2) (2-output type and cable type are 50 mA) (Note 2) * Applied voltage: 30 V DC or less (between output and 0 V) * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 2 V or less (Note 3) (at maximum sink current) * Residual voltage: 2 V or less (Note 3) (at maximum source current) Output points Fibers Super Quality 1 point 2 points Output operation Switchable either Light-ON or Dark-ON by L/D mode Short-circuit protection Incorporated Threaded Type Response time H-SP: 25 s or less, FAST: 60 s or less, STD: 250 s or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable Square Head Type Analog output (Cable type only) Output current: 4 to 20 mA approx. [H-SP, FAST, STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note 4)], Response time: 2 ms or less, Zero point: Within 4 mA 1 % F.S., Span: Within 16 mA 5 % F.S., Linearity: Within 3 % F.S., Load resistance: 0 to 250 External input (2-output type only, switchable with Output 2) - NPN non-contact input * Signal condition High: +8 V to +V DC or Open Low: 0 to +1.2 V DC (at 0.5 mA source current) * Input impedance: 10 k approx. Possible external input function - Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment Incident light intensity display range Timer function Vacuumresistant H-SP / FAST / STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999 Incorporated with variable OFF-delay / ON-delay /One-shot / ON OFF-delay / ON-delay * One-shot timer, switchable either effective or ineffective Heatresistant Incorporated with variable OFF-delay / ON-delay /One-shot / ON OFF-delay / ON-delay * One-shot timer, switchable either effective or ineffective Incorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either effective or ineffective Timer range "ms": 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx., Timer range "sec.": 0.5 s approx., 1 to 32 s approx., 1 s approx., Timer range "1/10 ms": 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx., each output is set individually Timer period Liquid Leak / Liquid Detection Fiber Options Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy lock / Display adjustment / Data bank load / Data bank save, selectable Sensitivity setting Retroreflective Type Chemical / Oilresistant Light emitting amount selection function Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode] Interference prevention function Incorporated (Note 5), selectable either automatic interference prevention or different frequency Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold tracking setting, etc. Various settings Protection Semi-custom fibers IP40 (IEC) -10 to +55 C +14 to +131 F [If 4 to 7 units are mounted in cascade: -10 to +50 C +14 to +122 F or if 8 to 16 units (cable type: 8 to 12 units) are mounted in cascade: -10 to +45 C +14 to +113 F] (No dew condensation or icing allowed), Storage: -20 to +70 C -4 to +158 F Ambient temperature Emitting element (modulated) Fiber Dimensions PNP non-contact input * Signal condition High: +4 V to +V DC (at 3 mA sink current) Low: 0 to +0.6 V DC or Open * Input impedance: 10 k approx. Red LED (Peak emission wavelength: 643 nm 0.025 mil) Material Enclosure, Case cover: Polycarbonate, Switch: TPEE Cable - 0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long Retroreflective Type Cable extension - Reflective Type Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (however, supply voltage 12 V DC) Weight Net weight: 15 g approx., Gross weight: 70 g approx. Net weight: 60 g approx., Gross weight: 100 g approx. Thru-beam Type Others Amplifiers FX-500 series FX-100 series FX-MB1 (Amplifier protection seal): 1 set Accessory Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2)50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) 3)In case of using the quick-connection cable (cable length 5 m 16.404 ft) (optional). 4)If display adjustment was conducted, it is not in this range. 5) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below. Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units. Number of sensor heads mountable closely (Unit: set) Response time H-SP FAST STD LONG U-LG HYPR IP-1 INDEX 0 2 4 8 8 12 77 I/O CIRCUIT AND WIRING DIAGRAMS New product introduction FX-501 NPN output type I/O circuit diagram Load (Black) Output 2 + Fiber Selection Guide + 12 to 24 V DC +10 % - -15 -15 Blue (Note 1) Note: The quick-connection sub cable does not have a brown and a blue lead wire. (Blue) 0 V (Note 1) Internal circuit Load Black 12 to 24 V DC +10 % - 100 mA max. (Note 2) 3 Color code of quick-connection cable Brown (Note 1) (Brown) +V (Note 1) 1 Sensor circuit Wiring diagram Terminal No. Color code of quick-connection cable User's circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 50 mA max., if five amplifiers or more, are connected together. Terminal arrangement diagram Sensor circuit 100 mA max. (Note 2) 2 3 + Fibers 3 0V Super Quality - (Black) Output 12 to 24 V DC +10 % - -15 Note: The quick-connection sub cable does not have a brown and a blue lead wire. User's circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 50 mA max., if five amplifiers or more, are connected together. Terminal arrangement diagram 1 +V 2 Output 3 0V Sensor circuit 1 4 2 Color code of quick-connection cable (Brown) +V (Note 1) (White) Output 2 / External input 50 mA max. (Note 2) (Black) Output 1 + - External input -15 Blue (Note 1) + User's circuit +V 2 Output 1 3 0V 4 Sensor circuit 1 2 4 3 Internal circuit Brown (Note 1) (Brown) +V (Note 1) 50 mA max. (Note 2) (Black) Output 1 50 mA max. (Note 2) (White) Output 2 / External input External input + - Black 12 to 24 V DC +10 % -15 Load Load (Blue) 0 V (Note 1) User's circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 mA max., if five amplifiers or more, are connected together. White Blue Load Load (Note 1) External input + 12 to 24 V DC +10 - % -15 Note: The quick-connection sub cable does not have a brown and a blue lead wire. Terminal arrangement diagram 1 +V 2 Output 1 3 0V Fiber Options Fiber Dimensions Color code of quick-connection cable Wiring diagram Color code of quick-connection cable Vacuumresistant Output 2 / External input PNP output type Terminal No. Heatresistant Semi-custom fibers FX-502P I/O circuit diagram Chemical / Oilresistant -15 External input Terminal arrangement diagram 1 Narrow Beam 12 to 24 V DC +10 % - Note: The quick-connection sub cable does not have a brown and a blue lead wire. Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 mA max., if five amplifiers or more, are connected together. Small Spot Liquid Leak / Liquid Detection Load Load Black 12 to 24 V DC +10 % (Blue) 0 V (Note 1) Internal circuit Color code of quick-connection cable White Load Load Flat Type Retroreflective Type Brown (Note 1) 50 mA max. (Note 2) 3 Wiring diagram Sleeve Wide Beam NPN output type Terminal No. Square Head Type Convergent Reflective Type FX-502 I/O circuit diagram Threaded Type Cylindrical Type + Load Blue (Note 1) -15 Load (Blue) 0 V (Note 1) Internal circuit Color code of quick-connection cable Black 12 to 24 V DC +10 % Earlier models comparison table Output Brown (Note 1) (Brown) +V (Note 1) 1 How to read Model No. 2 Wiring diagram Color code of quick-connection cable Choose by shape/ application +V PNP output type Terminal No. Model 1 FX-501P I/O circuit diagram Tough Fiber Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series 4 Output 2 / External input INDEX 78 I/O CIRCUIT AND WIRING DIAGRAMS New product introduction Tough Fiber FX-505-C2 NPN output type I/O circuit diagram Fiber Selection Guide Choose by shape/ application How to read Model No (Pink) External input Sensor circuit Model Wiring diagram Color code (Brown) +V Brown Load Load (Black) Output 1 + - (White) Output 2 Black 12 to 24 V DC 10 % 15 + Pink (Gray) Analog output (4 to 20 mA) Internal circuit Load White (Blue) 0 V Earlier models comparison table Load - 12 to 24 V DC 10 % 15 Blue Load (0 to 250 ) Load (0 to 250 ) Gray User's circuit Fibers Super Quality Threaded Type Square Head Type FX-505P-C2 I/O circuit diagram Cylindrical Type Wide Beam Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX + (White) Output 2 Load (Pink) External input (Blue) 0 V Narrow Beam Convergent Reflective Type Color code Brown (Black) Output 1 Sensor circuit Small Spot Wiring diagram (Brown) +V Sleeve Flat Type PNP output type User's circuit 12 to 24 V DC 10 % 15 Pink Black + White Load (Gray) Analog output (4 to 20 mA) Internal circuit - Load (0 to 250 ) Blue Gray Load Load - 12 to 24 V DC 10 % 15 Load (0 to 250 ) 79 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) L Fiber head H-SP 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FT-42W 300 11.811 3,000 118.110 2,000 78.740 Fiber head STD 1,000 39.370 L Fiber head H-SP 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) 1,000 0 1,000 39.370 39.370 Left Center Right Operating point (mm in) 1,500 59.055 1,000 39.370 Fiber head H-SP L Fiber head 500 19.685 1,000 0 1,000 39.370 39.370 Left Center Right Operating point (mm in) 4,000 157.480 2,000 78.740 STD Fiber head H-SP 1,000 39.370 L Fiber head 0 400 300 200 100 0 100 200 300 400 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Left Center Right Operating point (mm in) FTA162 3,000 118.110 2,000 78.740 1,000 39.370 500 19.685 Fiber head H-SP 8mm 0.315in L Fiber head 0 400 300 200 100 0 100 200 300 400 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Down Center Up Operating point (mm in) L Fiber head H-SP 1,000 0 1,000 39.370 39.370 Left Center Right Operating point (mm in) FT-45X Choose by shape/ application How to read Model No. STD Fiber head H-SP 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) 600 23.622 Fibers Super Quality Thru-beam type FTA186 Threaded Type Square Head Type Cylindrical Type HYPR 2,500 98.425 Sleeve 2,000 78.740 Flat Type 1,500 59.055 STD 1,000 39.370 H-SP Fiber head L Fiber head 500 19.685 0 2,000 78.740 Small Spot Narrow Beam Wide Beam 2,000 Convergent 78.740 Reflective Type 1,000 0 1,000 39.370 39.370 Left Center Right Operating point (mm in) Retroreflective Type Chemical / Oilresistant Thru-beam type FTA221 Heatresistant FTA185 500 19.685 Earlier models comparison table L Fiber head FT-42S 2,000 78.740 Model HYPR Vacuumresistant STD Liquid Leak / Liquid Detection 1,000 39.370 Fiber head H-SP Fiber Options L Fiber head 0 1,500 59.055 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) Semi-custom fibers 1,500 59.055 FT-A11W Thru-beam type FTA192 Horizontal direction 4,000 157.480 STD Setting distance L (mm in) 2,000 78.740 HYPR 1,000 39.370 Fiber head Fiber Selection Guide HYPR 500 19.685 3,000 118.110 STD Thru-beam type 1,000 39.370 0 600 23.622 HYPR 0 2,000 78.740 4,000 157.480 3,000 118.110 3,500 137.795 3,000 118.110 2,500 98.425 2,000 78.740 1,500 59.055 HYPR STD L Fiber head Thru-beam type FTA219 1,500 59.055 Horizontal direction FTA179 HYPR FT-42 Thru-beam type FTA224 2,000 78.740 0 800 600 400 200 0 200 400 600 800 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 Left Center Right Operating point (mm in) 2,000 78.740 Thru-beam type FTA183 Vertical direction Setting distance L (mm in) Setting distance L (mm in) FT-A11 L Fiber head H-SP 0 2,000 78.740 1,500 59.055 1,000 39.370 2,500 98.425 HYPR Fiber head STD STD Fiber head H-SP HYPR 2,000 78.740 FT-43 500 19.685 600 23.622 3,000 118.110 0 2,000 78.740 Thru-beam type FTA180 4,000 157.480 0 1,500 59.055 Setting distance L (mm in) Setting distance L (mm in) Fiber head STD 400 15.748 1,000 39.370 Thru-beam type FTA225 4,000 157.480 800 31.496 L Fiber head 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) FT-40 HYPR 1,000 39.370 0 300 11.811 0 600 23.622 1,500 59.055 FTA187 600 23.622 H-SP Thru-beam type 1,200 47.244 200 7.874 STD 500 19.685 HYPR Setting distance L (mm in) L Fiber head FT-31W Setting distance L (mm in) Fiber head 5,000 196.850 Fiber head 1,500 59.055 3,000 118.110 Vertical direction 4,000 157.480 HYPR STD H-SP 2,000 78.740 Fiber head 1,000 39.370 0 600 23.622 L Fiber head 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) 600 23.622 Setting distance L (mm in) H-SP Setting distance L (mm in) 10,000 393.700 1,000 39.370 Setting distance L (mm in) STD HYPR FT-31S Thru-beam type 1,500 59.055 Setting distance L (mm in) 15,000 590.550 Setting distance L (mm in) HYPR FT-31 Thru-beam type 1,500 59.055 Setting distance L (mm in) Setting distance L (mm in) 20,000 787.400 0 1,500 59.055 FT-30 Thru-beam type Setting distance L (mm in) FT-140 3,000 118.110 Fiber Dimensions Thru-beam Type Retroreflective Type HYPR Reflective Type STD Others H-SP 2,000 78.740 Fiber head 8mm 0.315in 1,000 39.370 0 600 23.622 L Amplifiers Fiber head FX-500 series 400 200 0 200 400 15.748 7.874 7.874 15.748 Down Center Up Operating point (mm in) 600 FX-100 23.622 series INDEX FTA162 FTA217 FTA217 80 SENSING CHARACTERISTICS (TYPICAL) New product introduction Thru-beam type Parallel deviationSensing characteristics are listed in the alphabetic order of the Model No. Tough Fiber (Models with same sensing characteristics are grouped together.) FT-A32 Fiber Selection Guide Vertical direction Horizontal direction Vertical direction 4,000 157.480 4,000 157.480 4,000 157.480 4,000 157.480 L Fiber head Square Head Type 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) 2,500 98.425 Setting distance L (mm in) Retroreflective Type Heatresistant L Fiber head 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) 4,000 157.480 Setting distance L (mm in) L 2,000 78.940 HYPR Fiber head STD 1,000 39.370 Fiber Dimensions Thru-beam Type H-SP 1,500 59.055 STD 500 19.685 H-SP 0 1,500 59.055 L Fiber head 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Down Center Up Operating point (mm in) STD Fiber head L Fiber head 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) 400 15.748 20 0.787 Fiber head 20 10 0 10 20 0.787 0.394 0.394 0.787 Left Center Right Operating point (mm in) 2,000 78.740 STD H-SP STD 150 5.906 100 3.937 50 1.969 150 5.906 Fiber head L Fiber head H-SP 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) 150 5.906 FTA223 STD 1,000 39.370 Fiber head 500 19.685 H-SP L Fiber head 1,000 0 1,000 39.370 39.370 Left Center Right Operating point (mm in) FT-H20W-M1 2,000 78.740 FT-H30-M1V-S Thru-beam type Thru-beam type Vertical direction HYPR L STD H-SP 1,500 59.055 400 15.748 HYPR 1,000 39.370 500 19.685 0 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) 200 7.874 2,000 78.740 Fiber head 0 400 15.748 HYPR 250 9.843 0 Horizontal direction HYPR 1,000 39.370 Thru-beam type FTA218 1,500 59.055 0 2,000 78.740 800 31.496 Thru-beam type 2,000 78.740 300 11.811 HYPR L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) FT-E23 30 1.181 L Fiber head Thru-beam type FTA222 Fiber head 800 31.496 Fiber head L H-SP 2,000 78.740 500 19.685 19mm 0.748in 300 11.811 STD FT-H20-M1 HYPR 300 11.811 HYPR 30 1.181 30 1.181 Fiber head 1,000 39.370 Thru-beam type FTA218 FT-H20-J20-SFT-H20-J30-S Thru-beam FTA215 type FT-H20-J50-S 1,000 39.370 2,000 78.740 300 11.811 40 1.575 0 1,500 59.055 Vertical direction HYPR H-SP 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) 50 1.969 10 0.394 H-SP 0 FT-E13 Fiber head 0 400 15.748 INDEX 36mm 1.417in Setting distance L (mm in) FX-100 series Fiber head 1,500 59.055 1,000 39.370 Horizontal direction 1,000 39.370 Fiber head 60 2.362 1,000 39.370 FT-H20-VJ50-SFT-H20-VJ80-S Setting distance L (mm in) FX-500 series 300 11.811 HYPR Others Amplifiers 1,000 39.370 3,000 118.110 0 0 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) 2,000 78.740 L 300 11.811 2,000 78.740 1,500 59.055 Fiber head 3,000 118.110 0 1,000 39.370 Reflective Type H-SP 500 19.685 Fiber head Thru-beam type FTA215 Liquid Leak / Liquid Detection Retroreflective Type 2,500 98.425 STD 1,000 39.370 Vertical direction FT-H13-FM2 Vacuumresistant Semi-custom fibers 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) H-SP 2,000 78.740 Thru-beam type FTA216 2,000 78.740 1,500 59.055 L Fiber head 300 11.811 300 11.811 HYPR 0 1,500 59.055 Chemical / Oilresistant Fiber Options 19mm 0.748in 1,000 39.370 Setting distance L (mm in) Convergent Reflective Type Fiber head 0 FTA216 Horizontal direction Sleeve Wide Beam 2,000 78.740 FT-AL05 Cylindrical Type Narrow Beam HYPR STD Fiber head Setting distance L (mm in) 300 11.811 H-SP 3,000 118.110 Setting distance L (mm in) 0 STD Setting distance L (mm in) 1,000 39.370 3,000 118.110 Setting distance L (mm in) Fiber head Threaded Type Small Spot HYPR 800 31.496 Setting distance L (mm in) 2,000 78.740 Super Quality Flat Type HYPR Setting distance L (mm in) H-SP Setting distance L (mm in) STD Setting distance L (mm in) Fibers 3,000 118.110 Setting distance L (mm in) Earlier models comparison table HYPR STD Setting distance L (mm in) How to read Model No Thru-beam type Horizontal direction Model Choose by shape/ application FT-A32W Thru-beam type STD H-SP Fiber head L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) 800 31.496 1,000 39.370 STD 500 19.685 H-SP 0 800 31.496 Fiber head L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) 800 31.496 81 SENSING CHARACTERISTICS (TYPICAL) New product introduction Thru-beam type Parallel deviationSensing characteristics are listed in the alphabetic order of the Model No. Tough Fiber (Models with same sensing characteristics are grouped together.) FT-H35-M2 FT-H35-M2S6 FT-HL80Y Thru-beam type 4,000 157.480 4,000 157.480 Thru-beam type Fiber Selection Guide HYPR Model 1,500 59.055 HYPR 1,000 39.370 STD 500 19.685 0 1,000 39.370 Fiber head H-SP L Fiber head 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) 3,000 118.110 2,000 78.740 STD H-SP 1,000 39.370 0 800 31.496 1,000 39.370 Setting distance L (mm in) HYPR Setting distance L (mm in) Setting distance L (mm in) 2,000 78.740 FT-KS40 Thru-beam type Fiber head L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) FT-KV26 3,000 118.110 Choose by shape/ application STD 2,000 78.740 How to read Model No. Fiber head H-SP Earlier models comparison table 1,000 39.370 L Fiber head 0 800 31.496 100 3.937 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) FT-KV40 Thru-beam type Fibers 100 3.937 Super Quality FTA208 Thru-beam type Horizontal direction Vertical direction Horizontal direction Vertical direction 3,000 118.110 3,000 118.110 4,000 157.480 4,000 157.480 1,500 59.055 STD 1,000 39.370 H-SP Fiber head L Fiber head 500 19.685 2,000 78.740 1,500 59.055 1,000 39.370 STD Fiber head H-SP 500 19.685 L Fiber head 3,000 118.110 STD 2,000 78.740 H-SP 0 100 3.937 80 60 40 20 0 20 40 60 80 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 Down Center Up Operating point (mm in) 80 60 40 20 0 20 40 60 80 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 Left Center Right Operating point (mm in) FT-KV40W FTA209 Vertical direction 4,000 157.480 4,000 157.480 HYPR Fiber head L Fiber head 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) FT-L80Y Thru-beam type FTA209 Horizontal direction 1,000 39.370 0 0 HYPR Setting distance L (mm in) Setting distance L (mm in) Setting distance L (mm in) 2,000 78.740 HYPR 2,500 98.425 Setting distance L (mm in) HYPR 2,500 98.425 STD 2,000 78.740 H-SP Flat Type Small Spot L Fiber head 50 0 50 1.969 1.969 Down Center Up Operating point (mm in) FT-R40 Thru-beam type FTA205 Narrow Beam Fiber head 0 4,000 157.480 HYPR Sleeve HYPR 3,000 118.110 100 3.937 4,000 157.480 Square Head Type Cylindrical Type 1,000 39.370 100 3.937 Threaded Type 100 3.937 Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Thru-beam type FTA205 Heatresistant Vacuumresistant Liquid Leak / Liquid Detection HYPR 1,000 39.370 0 100 3.937 Fiber head L Fiber head 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) FT-R41W H-SP Fiber head 1,000 39.370 0 100 3.937 100 3.937 L Fiber head 50 0 50 1.969 1.969 Down Center Up Operating point (mm in) 3,500 137.795 3,000 118.110 2,500 98.425 2,000 78.740 1,500 59.055 3,500 137.795 3,000 118.110 2,500 98.425 2,000 78.740 1,500 59.055 1,000 39.370 500 19.685 0 1,500 59.055 FTA206 HYPR Fiber head STD H-SP L Fiber head 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) FTA193 1,500 59.055 Setting distance L (mm in) Setting distance L (mm in) Horizontal direction Thru-beam type FTA206 Vertical direction 1,000 39.370 500 19.685 0 1,500 59.055 0 800 31.496 H-SP L Fiber head 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Down Center Up Operating point (mm in) FTA193 1,500 59.055 Fiber head L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) 3,000 118.110 STD 1,000 39.370 2,000 78.740 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) 4,000 157.480 STD Fiber head H-SP L Fiber head 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) FTA194 1,000 39.370 3,000 118.110 2,000 78.740 Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type HYPR Others STD Fiber head H-SP 1,000 39.370 0 1,000 39.370 Semi-custom fibers 1,500 59.055 FTA184 Vertical direction HYPR 1,000 39.370 0 1,000 39.370 L Fiber head Thru-beam type Horizontal direction 3,000 118.110 Fiber head H-SP 0 1,500 59.055 800 31.496 Fiber Options 2,000 78.740 FT-R42W HYPR STD H-SP 1,000 39.370 4,000 157.480 Fiber head STD 2,000 78.740 100 3.937 Setting distance L (mm in) 2,000 78.740 3,000 118.110 Setting distance L (mm in) H-SP STD Setting distance L (mm in) 2,000 78.740 3,000 118.110 Setting distance L (mm in) STD Setting distance L (mm in) Setting distance L (mm in) HYPR 3,000 118.110 500 0 500 19.685 19.685 Down Center Up Operating point (mm in) FTA194 L Fiber head Amplifiers FX-500 series FX-100 series 1,000 39.370 INDEX 82 SENSING CHARACTERISTICS (TYPICAL) New product introduction Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. 3,000 118.110 Narrow Beam Wide Beam Convergent Reflective Type Setting distance L (mm in) Small Spot Chemical / Oilresistant Heatresistant 4,000 157.480 Semi-custom fibers Setting distance L (mm in) Liquid Leak / Liquid Detection Fiber Options L H-SP Fiber head 1,000 0 1,000 39.370 39.370 Left Center Right Operating point (mm in) 2,000 78.740 FX-500 series FX-100 series Setting distance L (mm in) Reflective Type 500 19.685 Setting distance L (mm in) Fiber head 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) STD H-SP Fiber head L Fiber head STD 1,000 39.370 Fiber head L Fiber head H-SP 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) 0 800 600 400 200 0 200 400 600 800 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 Left Center Right Operating point (mm in) H-SP Fiber head FT-S32 STD Fiber head L H-SP Fiber head 0 800 600 400 200 0 200 400 600 800 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 Down Center Up Operating point (mm in) FTA226 Thru-beam type HYPR 800 31.496 600 23.622 Fiber head 400 15.748 200 7.874 0 300 11.811 STD Fiber head 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FTA182 STD H-SP Fiber head L Fiber head 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) 1,000 39.370 FT-V24W Thru-beam type FTA177 Horizontal direction Vertical direction 400 15.748 HYPR HYPR 300 11.811 STD 200 7.874 H-SP Fiber head L Fiber head 0 200 7.874 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) 200 7.874 200 7.874 100 3.937 STD L H-SP Fiber head 0 200 7.874 FTA190 FTA188 Fiber head 100 0 100 3.937 3.937 Down Center Up Operating point (mm in) INDEX FTA190 300 11.811 HYPR 1,000 39.370 100 3.937 L H-SP Thru-beam type 300 11.811 1,000 39.370 1,000 39.370 1,000 39.370 FTA220 2,000 78.740 0 1,000 39.370 L Fiber head 500 0 500 19.685 19.685 Down Center Up Operating point (mm in) FT-S21W 0 800 600 400 200 0 200 400 600 800 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 Left Center Right Operating point (mm in) 400 15.748 HYPR L 1,500 59.055 1,500 59.055 500 19.685 STD 3,000 118.110 2,000 78.740 HYPR 500 19.685 H-SP 1,200 47.244 Fiber head Fiber head STD 1,000 39.370 HYPR 4,000 157.480 2,000 78.740 2,000 78.740 0 1,000 39.370 FTA226 Thru-beam type HYPR 3,000 118.110 1,000 39.370 1,000 39.370 Thru-beam type FTA227 HYPR L Fiber head 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) FT-S21 600 23.622 Thru-beam type FTA181 Vertical direction 1,500 59.055 1,000 39.370 L 0 1,500 59.055 2,000 78.740 FT-V23 FTA226 Horizontal direction Amplifiers Fiber head STD Retroreflective Type Others 4,000 157.480 1,000 39.370 0 2,000 78.740 Fiber head 3,000 118.110 2,000 78.740 0 1,000 39.370 1,500 59.055 500 19.685 H-SP H-SP FTA227 Thru-beam type STD Fiber head STD 1,000 39.370 HYPR FT-S31W Thru-beam type FTA178 2,000 78.740 1,200 47.244 1,000 39.370 0 600 23.622 HYPR L Fiber head 800 400 0 400 800 31.496 15.748 15.748 31.496 Down Center Up Operating point (mm in) FT-S20 150 5.906 3,000 118.110 Fiber Dimensions Thru-beam Type Fiber head 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) FT-S30 Vacuumresistant Fiber head L H-SP 1,500 59.055 0 150 5.906 0 1,200 47.244 FTA227 Thru-beam type STD Fiber head H-SP HYPR 200 7.874 Retroreflective Type 1,000 39.370 1,200 47.244 300 11.811 100 3.937 STD 4,000 157.480 HYPR 3,000 118.110 Setting distance L (mm in) 400 15.748 Sleeve Flat Type 800 400 0 400 800 31.496 15.748 15.748 31.496 Left Center Right Operating point (mm in) FT-S11 Cylindrical Type L Fiber head HYPR Setting distance L (mm in) Threaded Type Square Head Type H-SP 0 1,200 47.244 Super Quality Setting distance L (mm in) 1,000 39.370 Fiber head Setting distance L (mm in) Fibers STD 4,000 157.480 2,000 78.740 Setting distance L (mm in) Earlier models comparison table 2,000 78.740 Setting distance L (mm in) How to read Model No Setting distance L (mm in) Choose by shape/ application HYPR Vertical direction Horizontal direction Setting distance L (mm in) Vertical direction 3,000 118.110 Thru-beam type Setting distance L (mm in) Horizontal direction Model FT-R60Y Thru-beam type Setting distance L (mm in) FT-R44Y Fiber Selection Guide Setting distance L (mm in) Tough Fiber FTA188 200 7.874 83 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. 1,000 39.370 400 15.748 L Fiber head 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FT-V40 Setting distance L (mm in) Setting distance L (mm in) 300 11.811 Fiber head L Fiber head 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) 300 11.811 Fiber head 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) FT-Z30 Setting distance L (mm in) 2,000 78.740 Fiber head 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) HYPR 3,000 118.110 H-SP 2.2mm 0.087in Fiber head L Fiber head 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) FTA198 1,000 39.370 2,000 78.740 STD 2,000 78.740 Fiber head H-SP L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) 0 1,000 39.370 Fibers 1,000 39.370 3,000 118.110 2,000 78.740 Threaded Type 500 19.685 L H-SP Fiber head Flat Type Small Spot STD Narrow Beam Wide Beam H-SP Fiber head Convergent Reflective Type L Fiber head 400 0 400 15.748 15.748 Down Center Up Operating point (mm in) 800 31.496 STD FTA198 Chemical / Oilresistant Vacuumresistant STD Fiber head 1.2mm 0.047in H-SP Fiber head L Fiber head Fiber head Fiber Dimensions Thru-beam Type FT-Z30E FTA294 Thru-beam type Vertical direction 3,000 118.110 2,000 78.740 STD Fiber head H-SP 1,000 39.370 300 11.811 4,000 157.480 HYPR L Fiber head 0 1,000 39.370 Semi-custom fibers L 400 300 200 100 0 100 200 300 400 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Down Center Up Operating point (mm in) 4,000 157.480 500 0 500 19.685 19.685 Down Center Up Operating point (mm in) Retroreflective Type Fiber Options 0 HYPR 5.5mm 0.217in Cylindrical Type Liquid Leak / Liquid Detection Horizontal direction H-SP Square Head Type Sleeve HYPR 1,000 39.370 0 800 31.496 800 31.496 Super Quality HYPR 1,000 39.370 Fiber head 1,000 39.370 500 0 500 19.685 19.685 Down Center Up Operating point (mm in) 1,500 59.055 Vertical direction STD L Fiber head Thru-beam type 400 300 200 100 0 100 200 300 400 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Left Center Right Operating point (mm in) 4,000 157.480 4,000 157.480 Earlier models comparison table Heatresistant FTA294 Thru-beam type HYPR H-SP Vertical direction STD 0 800 31.496 300 11.811 Fiber head FTA191 Thru-beam type HYPR FTA207 0 FTA203 1,000 39.370 0 1,000 39.370 L 0 1,000 39.370 1,000 39.370 3,000 118.110 1,000 39.370 500 19.685 FTA191 2,000 78.740 600 23.622 Horizontal direction 3,000 118.110 FT-V80Y 2,000 78.740 500 19.685 L 200 7.874 4,000 157.480 1,000 39.370 Fiber head STD 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) Vertical direction Setting distance L (mm in) 600 23.622 600 23.622 Fiber head 1,500 59.055 800 31.496 L Fiber head Horizontal direction Setting distance L (mm in) Setting distance L (mm in) 1,000 39.370 H-SP FT-Z20W STD 1,000 39.370 Fiber head H-SP 4,000 157.480 1,000 39.370 0 STD Horizontal direction STD 2,000 78.740 300 11.811 HYPR H-SP 0 1,000 39.370 Choose by shape/ application How to read Model No. 1,500 59.055 1,000 39.370 500 19.685 Model HYPR 2,000 78.740 1,500 59.055 300 11.811 HYPR 3,000 118.110 Thru-beam type FT-Z20HBWFTA207 0 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) 4,000 157.480 0 400 15.748 Fiber head Vertical direction H-SP 1,200 47.244 L FTA189 Thru-beam type 1,000 39.370 300 11.811 H-SP FTA189 STD 2,000 78.740 Fiber head 0 HYPR 3,000 118.110 200 7.874 300 11.811 Horizontal direction 4,000 157.480 400 15.748 Setting distance L (mm in) 300 11.811 H-SP STD 2,500 98.425 HYPR 2,000 78.740 Setting distance L (mm in) 200 7.874 0 Fiber head 600 23.622 Setting distance L (mm in) STD Setting distance L (mm in) 600 23.622 800 31.496 Setting distance L (mm in) Setting distance L (mm in) 800 31.496 2,500 98.425 HYPR Fiber Selection Guide Vertical direction Horizontal direction 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FTA163 300 11.811 Setting distance L (mm in) HYPR Thru-beam type Setting distance L (mm in) Vertical direction Horizontal direction 1,000 39.370 FT-V30 Thru-beam type Setting distance L (mm in) FT-V25 3,000 118.110 2,000 78.740 Reflective Type Others HYPR STD Amplifiers FX-500 series Fiber head H-SP 1,000 39.370 FX-100 series L 5.5mm 0.217in Fiber head 0 300 11.811 Retroreflective Type 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) FTA163 300 11.811 INDEX 84 SENSING CHARACTERISTICS (TYPICAL) New product introduction Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. INDEX L Fiber head 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) 3,000 118.110 STD Fiber head L H-SP Fiber head STD Fiber head 1.2mm 0.047in H-SP L Fiber head Setting distance L (mm in) STD Fiber head H-SP 400 15.748 L 5.5mm 0.217in Fiber head 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) 400 15.748 Thru-beam type FTA201 Vertical direction 4,000 157.480 3,000 118.110 H-SP 2.2mm 0.087in Fiber head L Fiber head 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) 2,000 78.740 HYPR STD Fiber head H-SP 1,000 39.370 0 1,000 39.370 1,000 39.370 L 5.5mm 0.217in Fiber head 500 0 500 19.685 19.685 Down Center Up Operating point (mm in) 1,000 39.370 Thru-beam type FT-Z40HBWFTA199 Thru-beam type FT-Z802Y FTA199 4,000 157.480 4,000 157.480 HYPR HYPR 3,000 118.110 3,000 118.110 2,000 78.740 1,000 39.370 0 STD 1,000 39.370 HYPR 1,000 39.370 400 15.748 HYPR 2,000 78.740 0 1,000 39.370 400 15.748 HYPR 2,000 78.740 FT-Z30W FTA201 Thru-beam type FTA202 HYPR 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) 3,000 118.110 Setting distance L (mm in) 5.5mm 0.217in FTA202 0 800 600 400 200 0 200 400 600 800 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 Left Center Right Operating point (mm in) 2,000 78.740 STD 1,000 39.370 0 1,500 59.055 0 800 600 400 200 0 200 400 600 800 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 Down Center Up Operating point (mm in) Fiber head H-SP L Fiber head 1,000 500 0 500 1,000 39.370 19.685 19.685 39.370 Left Center Right Operating point (mm in) 2,000 78.740 H-SP Fiber head 1,000 39.370 0 800 31.496 1,500 59.055 STD L Fiber head 400 0 400 15.748 15.748 Left Center Right Operating point (mm in) 800 31.496 Retroreflective type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. FR-KZ22E FTA295 Retroreflective type FTA295 Vertical direction Horizontal direction Setting distance L (mm in) FX-100 series 0 400 15.748 400 15.748 3,000 118.110 600 23.622 FX-500 series 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) 1,000 39.370 4,000 157.480 Reflective Type Amplifiers L Fiber head Vertical direction 1,000 39.370 400 15.748 3,000 118.110 H-SP 4,000 157.480 Thru-beam Type Others 1,000 39.370 2,000 78.740 0 L Fiber head 4,000 157.480 Fiber head 2,000 78.740 Horizontal direction STD Horizontal direction Fiber Dimensions Retroreflective Type Fiber head H-SP Fiber head H-SP 1,000 39.370 400 15.748 HYPR 3,000 118.110 STD FT-Z40W Setting distance L (mm in) Semi-custom fibers 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) STD 2,000 78.740 FTA200 Thru-beam type HYPR 2,000 78.740 0 400 15.748 Heatresistant Fiber Options 400 15.748 4,000 157.480 Chemical / Oilresistant Liquid Leak / Liquid Detection 0 400 15.748 Vertical direction Retroreflective Type Vacuumresistant Fiber head 4,000 157.480 3,000 118.110 L 5.5mm 0.217in 4,000 157.480 600 23.622 HYPR 500 19.685 400 15.748 STD 300 11.811 200 7.874 Reflector H-SP L 100 3.937 0 20 0.787 Fiber head 10 0 10 0.394 0.394 Left Center Right Operating point (mm in) FRA014 20 0.787 STD 300 11.811 200 7.874 Reflector H-SP L 100 3.937 0 20 0.787 Fiber head 10 0 10 0.394 0.394 Down Center Up Operating point (mm in) 20 0.787 FTA204 Retroreflective type Horizontal direction Vertical direction 1,200 47.244 1,200 47.244 HYPR 500 19.685 400 15.748 FR-KZ50E HYPR 1,000 39.370 800 31.496 600 23.622 400 15.748 200 7.874 0 10 0.394 STD Reflector RF-003 H-SP L Fiber head 5 0 5 0.197 0.197 Left Center Right Operating point (mm in) 10 0.394 Setting distance L (mm in) Convergent Reflective Type 1,000 39.370 Horizontal direction Setting distance L (mm in) Wide Beam 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) Fiber head H-SP FT-Z30HW FTA200 Sleeve Narrow Beam L Fiber head 2,000 78.740 Setting distance L (mm in) 400 15.748 Square Head Type Small Spot 1,000 39.370 Threaded Type Flat Type Fiber head H-SP Vertical direction HYPR 3,000 118.110 STD Setting distance L (mm in) 2,000 78.740 HYPR 3,000 118.110 STD 0 Super Quality Setting distance L (mm in) 3,000 118.110 Fibers Cylindrical Type HYPR Setting distance L (mm in) Earlier models comparison table 4,000 157.480 Setting distance L (mm in) How to read Model No Horizontal direction 4,000 157.480 Setting distance L (mm in) Choose by shape/ application Setting distance L (mm in) Model Thru-beam type Vertical direction Setting distance L (mm in) Horizontal direction 4,000 157.480 FT-Z30H Thru-beam type Setting distance L (mm in) FT-Z30EW Fiber Selection Guide Setting distance L (mm in) Tough Fiber HYPR 1,000 39.370 800 31.496 600 23.622 STD 400 15.748 H-SP Reflector RF-003 3mm 0.118in L 200 7.874 0 10 0.394 Fiber head 5 0 5 0.197 0.197 Down Center Up Operating point (mm in) 10 0.394 85 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Retroreflective type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. FR-KZ50H Retroreflective type Vertical direction Fiber Selection Guide 1,200 47.244 1,200 47.244 Model HYPR 1,000 39.370 800 31.496 600 23.622 STD 400 15.748 H-SP Reflector RF-003 L 200 7.874 Fiber head 0 20 0.787 10 0 10 0.394 0.394 Left Center Right Operating point (mm in) Setting distance L (mm in) Setting distance L (mm in) Horizontal direction Choose by shape/ application 800 31.496 How to read Model No. 600 23.622 STD 400 15.748 H-SP 20 0.787 Earlier models comparison table Reflector RF-003 L 200 7.874 0 20 0.787 HYPR 1,000 39.370 Fiber head 10 0 10 0.394 0.394 Down Center Up Operating point (mm in) Fibers 20 0.787 Super Quality FR-Z50HW Retroreflective type 2,000 78.740 1,500 59.055 STD 1,000 39.370 H-SP Reflective tape RF-13 500 19.685 L Fiber head 1,500 59.055 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) STD 1,000 39.370 Reflective tape RF-13 H-SP 500 19.685 0 150 5.906 HYPR 0 150 5.906 150 5.906 L Fiber head 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) Setting distance L (mm in) HYPR Setting distance L (mm in) Setting distance L (mm in) 2,000 78.740 With reflector RF-230 (optional) Horizontal direction Vertical direction 4,000 157.480 4,000 157.480 HYPR 3,000 118.110 STD 2,000 78.740 H-SP HYPR 3,000 118.110 STD 2,000 78.740 H-SP Reflector RF-230 1,000 39.370 L Fiber head Setting distance L (mm in) FRA013 With Reflective tape RF-13 (attached) FRA013 Horizontal direction Vertical direction Cylindrical Type Flat Type Small Spot Narrow Beam Reflector RF-230 Wide Beam L Fiber head 0 400 300 200 100 0 100 200 300 400 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Down Center Up Operating point (mm in) Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. FRA010 Reflective type FD-30 Vertical direction 800 31.496 HYPR 600 23.622 STD 400 15.748 0 150 5.906 L Fiber head H-SP Left HYPR 0 150 5.906 150 5.906 STD White non-glossy paper L Fiber head H-SP Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) FDA262 Vertical direction 400 15.748 400 15.748 Setting distance L (mm in) Setting distance L (mm in) Horizontal direction FDA262 100 3.937 0 60 2.362 200 7.874 100 3.937 0 150 5.906 150 5.906 HYPR STD H-SP White non-glossy paper L Fiber head Left Right 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) 60 2.362 0 60 2.362 H-SP Left Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) FD-32G 150 5.906 Reflective type FDA256 STD H-SP L Fiber head Up Down 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) 60 2.362 STD H-SP Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options HYPR 500 19.685 400 15.748 STD 300 11.811 200 7.874 100 3.937 0 150 5.906 Semi-custom fibers White non-glossy paper L Fiber head H-SP Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) FDA256 150 5.906 Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others FX-500 series White non-glossy paper FX-100 series L Fiber head 200 7.874 0 200 7.874 Retroreflective Type Amplifiers 400 15.748 White non-glossy paper Convergent Reflective Type HYPR 600 23.622 200 7.874 100 3.937 White non-glossy paper L Fiber head 800 31.496 300 11.811 200 7.874 STD 300 11.811 Reflective type 300 11.811 600 23.622 HYPR 400 15.748 FD-31W HYPR Vertical direction 500 19.685 400 15.748 Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) 600 23.622 600 23.622 200 7.874 FRA011 Horizontal direction Setting distance L (mm in) 200 7.874 White non-glossy paper Setting distance L (mm in) Setting distance L (mm in) 800 31.496 Setting distance L (mm in) Horizontal direction FD-31 FRA011 Reflective type Setting distance L (mm in) FRA010 Square Head Type Sleeve 1,000 39.370 0 400 300 200 100 0 100 200 300 400 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Left Center Right Operating point (mm in) 150 5.906 Threaded Type Left Right 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) FDA233 200 7.874 INDEX 86 SENSING CHARACTERISTICS (TYPICAL) New product introduction Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. 600 23.622 Heatresistant Semi-custom fibers H-SP Left 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) 400 15.748 100 3.937 White non-glossy paper L Fiber head H-SP Left Reflective Type Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) Setting distance L (mm in) 600 23.622 STD H-SP White non-glossy paper L Fiber head 200 7.874 0 200 7.874 L Fiber head H-SP Up Down 20 0 20 0.787 0.787 Down Center Up Operating point (mm in) Left Right 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) 200 7.874 STD H-SP White non-glossy paper L Fiber head 200 7.874 100 3.937 300 11.811 200 7.874 White non-glossy paper L Fiber head H-SP 100 3.937 Left Right 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) Left Right 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) 100 3.937 White non-glossy paper 400 15.748 L Fiber head H-SP Left Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) STD White non-glossy paper L Fiber head H-SP 400 15.748 H-SP 100 3.937 50 0 50 1.969 1.969 Down Center Up Operating point (mm in) HYPR 600 23.622 STD 400 15.748 200 7.874 Left 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) FDA260 White non-glossy paper L Fiber head H-SP Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) 150 5.906 Right 400 15.748 HYPR 1,500 59.055 STD 1,000 39.370 500 19.685 White non-glossy paper L Fiber head H-SP Up Down 0 0.000 400 15.748 200 0 200 7.874 0.000 7.874 Down Center Up Operating point (mm in) Setting distance L (mm in) Setting distance L (mm in) FDA203 FDA235 100 3.937 800 31.496 2,000 78.740 HYPR 1,500 59.055 0 200 7.874 Reflective type FDA218 Vertical direction FDA218 Horizontal direction 500 19.685 Up Down STD 300 11.811 0 150 5.906 150 5.906 FD-60 1,000 39.370 400 15.748 1,000 39.370 STD 200 7.874 L Fiber head Reflective type FDA223 Vertical direction 800 31.496 600 23.622 White non-glossy paper HYPR 500 19.685 0 100 3.937 100 3.937 HYPR 2,000 78.740 600 23.622 0 STD 0 150 5.906 HYPR 400 15.748 400 15.748 FD-41W 40 1.575 Reflective type FDA224 800 31.496 600 23.622 500 19.685 1,000 39.370 White non-glossy paper FD-42GW Vertical direction FDA223 Horizontal direction STD 40 1.575 40 1.575 HYPR 400 15.748 100 3.937 Reflective type HYPR 0 100 3.937 150 5.906 300 11.811 200 7.874 150 5.906 Horizontal direction FDA261 600 HYPR 0 Reflective type FDA224 800 31.496 Others Right 20 0 20 0.787 0.787 Left Center Right Operating point (mm in) FD-42G Retroreflective Type INDEX H-SP 400 15.748 STD 200 7.874 40 1.575 Thru-beam Type FX-100 series L Fiber head Vertical direction HYPR 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) FD-41S Reflective type FDA258 300 11.811 Fiber Dimensions FX-500 series 100 3.937 0 150 5.906 150 5.906 Horizontal direction 0 Amplifiers Right White non-glossy paper 200 7.874 FD-41SW FDA258 Setting distance L (mm in) Fiber Options L Fiber head Up Down 23.622 STD 300 11.811 White non-glossy paper L Fiber head H-SP 150 5.906 HYPR 400 15.748 STD 200 7.874 White non-glossy paper 0 150 5.906 500 19.685 200 7.874 0 150 5.906 Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) 600 23.622 HYPR 300 11.811 100 3.937 Left Reflective type FDA261 Vertical direction 400 15.748 Chemical / Oilresistant Liquid Leak / Liquid Detection 200 7.874 500 19.685 Retroreflective Type Vacuumresistant 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) H-SP 0 150 5.906 STD 400 15.748 Setting distance L (mm in) Convergent Reflective Type Right Fiber head 600 23.622 Setting distance L (mm in) Wide Beam Left L 200 7.874 HYPR Setting distance L (mm in) Narrow Beam L Fiber head Setting distance L (mm in) Small Spot H-SP 200 7.874 White non-glossy paper STD 400 15.748 White non-glossy paper FDA234 Horizontal direction Setting distance L (mm in) Flat Type STD 400 15.748 FD-41 Sleeve 800 31.496 HYPR Setting distance L (mm in) Threaded Type Cylindrical Type Vertical direction 600 23.622 600 23.622 0 200 7.874 Super Quality Square Head Type HYPR Setting distance L (mm in) Fibers 800 31.496 Setting distance L (mm in) Earlier models comparison table Setting distance L (mm in) How to read Model No Reflective type Horizontal direction 800 31.496 Model Choose by shape/ application FD-40 Reflective type Setting distance L (mm in) FD-32GX Fiber Selection Guide Setting distance L (mm in) Tough Fiber FDA260 400 15.748 87 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. Vertical direction 1,500 59.055 1,500 59.055 White non-glossy paper STD 500 19.685 L Fiber head H-SP Left 0 Right 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) 1,000 39.370 White non-glossy paper STD 500 19.685 L Fiber head H-SP 0 600 23.622 600 23.622 1,200 47.244 HYPR Up Down 400 200 0 200 400 15.748 7.874 7.874 15.748 Down Center Up Operating point (mm in) FD-61S 1,500 59.055 HYPR 1,000 39.370 STD White non-glossy paper 500 19.685 L Fiber head H-SP Left 0 400 15.748 Setting distance L (mm in) Setting distance L (mm in) FDA259 Vertical direction 1,500 59.055 Right 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) STD 500 19.685 L Fiber head H-SP Up Down 0 400 15.748 400 15.748 400 15.748 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) FD-62 H-SP 600 23.622 Left Fibers Right 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) 600 23.622 Super Quality FD-61W Reflective type FDA200 Horizontal direction Vertical direction 1,000 39.370 HYPR 800 31.496 STD 600 23.622 White non-glossy paper 400 15.748 200 7.874 0 150 5.906 400 15.748 L Fiber head H-SP Left Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) FD-64X Flat Type 600 23.622 STD 400 15.748 0 150 5.906 150 5.906 Small Spot White non-glossy paper Narrow Beam L Fiber head H-SP Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) 150 5.906 Vertical direction FDA216 Horizontal direction 2,000 78.740 2,000 78.740 800 31.496 800 31.496 600 23.622 Left Right 400 200 0 200 400 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) 600 23.622 250 9.843 STD 150 5.906 White non-glossypaper 200mm 7.874in H-SP 50 1.969 L Fiber head 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FDA225 200 7.874 0 600 23.622 300 11.811 60 2.362 150 5.906 100 3.937 H-SP 50 1.969 0 60 2.362 White non-glossy paper 200mm 7.874in L Fiber head 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) FDA225 60 2.362 L Fiber head Left L Fiber head H-SP Up Down 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) 300 11.811 Reflective type FDA248 Vertical direction Horizontal direction 800 31.496 HYPR Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others HYPR 600 23.622 600 23.622 400 15.748 0 300 11.811 300 11.811 Retroreflective Type 0 300 11.811 FD-AL11 FDA248 200 7.874 200 7.874 White non-glossy paper STD 400 15.748 Right 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) 800 31.496 200 7.874 White non-glossy paper H-SP STD Setting distance L (mm in) Setting distance L (mm in) 400 200 0 200 400 15.748 7.874 7.874 15.748 Down Center Up Operating point (mm in) 250 9.843 200 7.874 0 60 2.362 Up Down Reflective type FDA220 Vertical direction FDA220 Horizontal direction 100 3.937 H-SP 0 600 23.622 FD-A16 L Fiber head STD 400 15.748 Setting distance L (mm in) H-SP 500 19.685 White non-glossypaper HYPR 600 23.622 STD H-SP 400 15.748 White non-glossy paper L Fiber head 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FDA252 Setting distance L (mm in) 0 L Fiber head STD 1,000 39.370 HYPR 600 23.622 Setting distance L (mm in) 500 19.685 White non-glossy paper 1,500 59.055 Setting distance L (mm in) STD 1,000 39.370 Setting distance L (mm in) 1,500 59.055 HYPR Wide Beam Convergent Reflective Type Chemical / Oilresistant FDA222 Horizontal direction HYPR Square Head Type Sleeve HYPR 800 31.496 200 7.874 Threaded Type Cylindrical Type Reflective type FDA216 Vertical direction Setting distance L (mm in) Reflective type FDA222 L Fiber head 200 7.874 0 Earlier models comparison table 1,000 39.370 White non-glossy paper How to read Model No. White non-glossy paper STD 600 23.622 HYPR 1,000 39.370 Choose by shape/ application 800 31.496 600 23.622 Reflective type FDA259 Horizontal direction Model HYPR 1,000 39.370 Setting distance L (mm in) 1,000 39.370 Reflective type Fiber Selection Guide Setting distance L (mm in) HYPR Setting distance L (mm in) Setting distance L (mm in) Horizontal direction 600 23.622 FD-61G Reflective type Setting distance L (mm in) FD-61 300 11.811 STD Amplifiers White non-glossy paper FX-500 series 200 H-SP 7.874 0 300 11.811 3.6mm 0.142in L Fiber head 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) FDA252 FX-100 series 300 11.811 INDEX 88 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. FD-E13 10 0.394 Left 0 15 0.591 Super Quality Threaded Type Square Head Type Cylindrical Type Small Spot Narrow Beam Wide Beam Setting distance L (mm in) Sleeve Flat Type L Fiber head Convergent Reflective Type 150 5.906 STD 100 3.937 H-SP 50 1.969 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) 80 3.150 Setting distance L (mm in) Horizontal direction L STD 20 0.787 H-SP Fiber Dimensions STD H-SP 2 0 2 0.079 0.079 Left Center Right Operating point (mm in) 20 10 0 10 20 0.787 0.394 0.394 0.787 Left Center Right Operating point (mm in) 80 3.150 Setting distance L (mm in) Others HYPR 40 1.575 STD 0 4 0.157 Transparent glass Emitter L H-SP 2 0 2 0.079 0.079 Down Center Up Operating point (mm in) 4.5mm 0.177in 40 1.575 100mm, (t=0.7mm) 3.937in, (t=0.028in) L STD 20 0.787 H-SP 0 4 0.157 4 0.157 Vertical direction HYPR 10 0.394 H-SP 50 1.969 L Fiber head 20 0 20 0.787 0.787 Left Center Right Operating point (mm in) 60 2.362 40 1.575 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FD-H13-FM2 Reflective type FDA243 60 2.362 FDA246 1,000 39.370 L Fiber head HYPR 500 19.685 STD H-SP 0 400 15.748 30 1.181 Reflective type 30 1.181 40 1.575 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) FD-H20-21 Transparent glass 100mm,(t=0.7mm) 3.937in,(t=0.028in) 60 2.362 20 0.787 4 0.157 Horizontal direction 40 1.575 White non-glossy paper 200mm 7.874in L Fiber head FD-H25-L43 Reflective Type White non-glossy paper 200mm 7.874in STD 100 3.937 400 15.748 FD-H20-M1 Reflective type Reflective type Vertical direction 4mm 0.157in 40 1.575 150 5.906 0 0 15 0.591 HYPR White non-glossy paper 20 0.787 30 1.181 White non-glossy paper 200mm 7.874in L Fiber head HYPR 60 2.362 40 1.575 H-SP 50 1.969 Reflective type HYPR 4 0.157 INDEX 10 5 0 5 10 0.394 0.197 0.197 0.394 Down Center Up Operating point (mm in) 80 3.150 0 60 2.362 Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) 60 2.362 0 FX-100 series White non-glossy paper 200mm 7.874in L Fiber head Liquid Leak / Liquid Detection FX-500 series Up Down 100 3.937 Vacuumresistant Amplifiers 0 15 0.591 15 0.591 HYPR FD-H18-L31 Retroreflective Type L Fiber head 200 7.874 60 2.362 Thru-beam Type H-SP 10 0.394 Right 10 5 0 5 10 0.394 0.197 0.197 0.394 Left Center Right Operating point (mm in) Heatresistant Semi-custom fibers 20 0.787 STD 100 3.937 Reflective type FD-EG31 FDA242 Chemical / Oilresistant Fiber Options STD 30 1.181 150 5.906 White non-glossy paper 200mm 7.874in Reflective type FD-EG30S FDA242 0 Retroreflective Type 40 1.575 Setting distance L (mm in) H-SP 50 1.969 HYPR 30 1.181 20 0.787 STD Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) Emitter L H-SP 10 0.394 0 2 0 2 0.079 0.079 Left Center Right Operating point (mm in) 4 0.157 4 0.157 2 0 2 0.079 0.079 Down Center Up Operating point (mm in) 4 0.157 White non-glossy paper L Fiber head HYPR 1,000 39.370 500 19.685 STD H-SP 0 200 7.874 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) 200 7.874 Setting distance L (mm in) 20 0.787 Reflective type 200 7.874 HYPR Setting distance L (mm in) STD 30 1.181 Setting distance L (mm in) Fibers White non-glossy paper 200mm 7.874in Setting distance L (mm in) Earlier models comparison table 40 1.575 Setting distance L (mm in) How to read Model No 200 7.874 HYPR Setting distance L (mm in) 50 1.969 60 2.362 HYPR Setting distance L (mm in) Choose by shape/ application Setting distance L (mm in) Model FD-EG30 Reflective type Vertical direction Horizontal direction 60 2.362 FD-E23 Reflective type Setting distance L (mm in) Fiber Selection Guide HYPR 1,000 39.370 STD 500 19.685 White non-glossy paper H-SP 0 200 7.874 L Fiber head 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) 200 7.874 89 SENSING CHARACTERISTICS (TYPICAL) New product introduction Reflective type Sensing fieldSensing characteristics are listed in the alphabetic order of the Model No. Tough Fiber (Models with same sensing characteristics are grouped together.) Vertical direction Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) 4.5mm 0.177in L STD H-SP Emitter STD H-SP 20 0.787 2 0 2 0.079 0.079 Left Center Right Operating point (mm in) 4 0.157 4 0.157 1 0 1 0.039 0.039 Left Center Right Operating point (mm in) H-SP 2 0.079 2 0.079 1 0 1 0.039 0.039 Down Center Up Operating point (mm in) Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 2 0.079 L 6 0.236 HYPR STD 2 0.079 FD-H35-M2 FD-H35-M2S6 4 0.157 2 0.079 Vertical direction L H-SP 0 0.5 0 0.5 0.020 0.020 Left Center Right Operating point (mm in) FDA251 1 0.039 10 0.394 5 0.197 0 1 0.039 STD H-SP 0.5 0 0.5 0.020 0.020 Down Center Up Operating point (mm in) FDA251 1 0.039 200 7.874 200 7.874 Small Spot Fiber head Narrow Beam STD Wide Beam Convergent Reflective Type H-SP 100 0 100 3.937 3.937 Left Center Right Operating point (mm in) HYPR H-SP L 15 0.591 2 0 2 0.079 0.079 Left Center Right Operating point (mm in) 4 0.157 HYPR STD 10 0.394 200 7.874 H-SP Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 2mm L 0.079in Fiber Options 5 0.197 4 0.157 Semi-custom fibers 2 0 2 0.079 0.079 Down Center Up Operating point (mm in) 50 1.969 HYPR 40 1.575 STD 30 1.181 20 0.787 H-SP 10 0.394 0 15 0.591 White non-glossy paper 200mm 7.874in L Fiber head 10 5 0 5 10 0.394 0.197 0.197 0.394 Left Center Right Operating point (mm in) FDA226 4 0.157 15 0.591 Fiber Dimensions Thru-beam Type FDA231 Reflective type FD-L20H FDA231 Horizontal direction Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 1.5mm L 0.059in HYPR Flat Type L 0 4 0.157 Setting distance L (mm in) STD 15 0.591 Setting distance L (mm in) Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) HYPR Sleeve Vertical direction Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 5 0.197 3 0.118 Cylindrical Type HYPR 400 15.748 0 2 1 0 1 2 0.079 0.039 0.039 0.079 Down Center Up Operating point (mm in) Square Head Type Reflective type 400 15.748 Super Quality Threaded Type Reflective type STD 10 0.394 2 0.079 White non-glossy paper 600 23.622 0 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) 15 0.591 FDA232 Reflective type FDA232 Horizontal direction STD H-SP Horizontal direction Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) 2mm L 0.079in H-SP 3 0.118 3 0.118 500 19.685 1 0 1 0.039 0.039 Down Center Up Operating point (mm in) FD-L11 0 2 1 0 1 2 0.079 0.039 0.039 0.079 Left Center Right Operating point (mm in) HYPR Earlier models comparison table Fibers 2 0.079 800 31.496 Fiber head How to read Model No. L H-SP 0 2 0.079 White non-glossy paper L 1,000 39.370 0 400 15.748 Setting distance L (mm in) STD Setting distance L (mm in) Setting distance L (mm in) HYPR FD-L12W Setting distance L (mm in) L Reflective type 4 0.157 1 0.039 1 0 1 0.039 0.039 Left Center Right Operating point (mm in) Choose by shape/ application STD 20 0.787 FD-H35-20S Reflective type 0 H-SP 5 0.197 STD 8 0.315 10 0.394 2 0.079 4 0.157 10 0.394 Vertical direction 15 0.591 H-SP Emitter HYPR 40 1.575 Setting distance L (mm in) H-SP Emitter 8 0.315 3 0.118 L Setting distance L (mm in) L HYPR Horizontal direction 0 STD 20 0.787 Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) FD-L10 6 0.236 40 1.575 Setting distance L (mm in) 20 0.787 Setting distance L (mm in) Setting distance L (mm in) Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) 0 2 0.079 HYPR Model Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) 60 2.362 Vertical direction STD 10 0.394 60 2.362 Reflective type Horizontal direction HYPR 80 3.150 Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 0 2 0 2 0.079 0.079 Down Center Up Operating point (mm in) FD-H30-L32V-S 20 0.787 L 80 3.150 0 0 4 0.157 40 1.575 Fiber Selection Guide Vertical direction Setting distance L (mm in) 40 1.575 Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) HYPR Setting distance L (mm in) Setting distance L (mm in) HYPR Reflective type Horizontal direction Setting distance L (mm in) Horizontal direction 20 0.787 FD-H30-L32 Reflective type Setting distance L (mm in) FD-H25-L45 Retroreflective Type Vertical direction Reflective Type 50 1.969 Others HYPR 40 1.575 STD Amplifiers 30 1.181 White non-glossy paper 200mm 7.874in 20 0.787 H-SP 10 0.394 0 15 0.591 L Fiber head 10 5 0 5 10 0.394 0.197 0.197 0.394 Down Center Up Operating point (mm in) FDA226 15 0.591 FX-500 series FX-100 series INDEX 90 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. 20 0.787 Threaded Type Square Head Type L 2 0 2 0.079 0.079 Left Center Right Operating point (mm in) Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 2.5mm L 0.098in 04 0.157 4 0.157 2 0 2 0.079 0.079 Down Center Up Operating point (mm in) Setting distance L (mm in) Setting distance L (mm in) Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) H-SP H-SP 6 0.236 Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 20 0.787 10 0.394 L 4 2 0 2 4 0.157 0.079 0.079 0.157 Left Center Right Operating point (mm in) H-SP 30 1.181 Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 2.5mm L 0.098in 20 0.787 10 0.394 0 6 0.236 6 0.236 FDA202 Horizontal direction Setting distance L (mm in) 120 4.724 HYPR 100 3.937 80 3.150 STD 60 2.362 Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) R edge(R0.35 R0.014) L 40 1.575 20 0.787 0 10 0.394 5 0 5 0.197 0.197 Left Center Right Operating point (mm in) FDA230 10 0.394 120 4.724 80 3.150 STD 60 2.362 Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) R edge (R0.35 R0.014) 0 10 0.394 5 0 5 0.197 0.197 Down Center Up Operating point (mm in) FDA230 L 10 0.394 06 0.236 HYPR STD H-SP Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 2.5mm L 0.098in 4 2 0 2 4 0.157 0.079 0.079 0.157 Down Center Up Operating point (mm in) H-SP 20 0.787 10 0.394 4 2 0 2 4 0.157 0.079 0.079 0.157 Left Center Right Operating point (mm in) 40 1.575 HYPR STD 30 1.181 H-SP Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) 3mm L 0.118in 20 0.787 10 0.394 0 6 0.236 6 0.236 4 2 0 2 4 0.157 0.079 0.079 0.157 Down Center Up Operating point (mm in) Vertical direction 1,200 47.244 HYPR 1,000 39.370 800 31.496 STD 400 15.748 200 7.874 0 300 11.811 6 0.236 FDA229 Reflective type FD-R60 600 23.622 6 0.236 Vertical direction L 1,200 47.244 40 1.575 20 0.787 30 1.181 6 0.236 HYPR 100 3.937 STD 2 0.079 Reflective type FDA205 FDA229 Horizontal direction Vertical direction 35 1.378 30 1.181 25 0.984 20 0.787 15 0.591 10 0.394 5 0.197 6 0.236 Transparent glass 100mm, (t=0.7mm) 3.937in, (t=0.028in) HYPR 0 6 0.236 FDA202 Reflective type FD-L32H Others 4 2 0 2 4 0.157 0.079 0.079 0.157 Down Center Up Operating point (mm in) Setting distance L (mm in) 6 0.236 STD Setting distance L (mm in) H-SP 40 1.575 Setting distance L (mm in) Setting distance L (mm in) 30 1.181 STD HYPR L 1 0 1 0.039 0.039 Down Center Up Operating point (mm in) FD-L31A 40 1.575 40 1.575 3mm 0.118in Vertical direction 4 2 0 2 4 0.157 0.079 0.079 0.157 Left Center Right Operating point (mm in) 50 1.969 HYPR 5 0.197 Transparent glass 200mm 7.874in (t=2.0mm) (t=0.079in) Reflective type FDA228 L 0 4 0.157 Reflective type FDA201 STD Vertical direction Retroreflective Type INDEX H-SP STD H-SP 10 0.394 2 0.079 4 0.157 Transparent glass 100mm 3.937in (t=0.7mm) (t=0.028in) HYPR 50 1.969 Thru-beam Type FX-100 series STD HYPR FDA205 Horizontal direction Fiber Dimensions FX-500 series HYPR STD 15 0.591 FDA228 FDA201 Horizontal direction 0 Amplifiers FD-L23 Reflective type FDA227 FD-L30A Liquid Leak / Liquid Detection 2 0 2 0.079 0.079 Left Center Right Operating point (mm in) 35 1.378 30 1.181 25 0.984 20 0.787 15 0.591 10 0.394 5 0.197 04 0.157 Vacuumresistant 4 0.157 3 0.118 Horizontal direction Heatresistant Reflective Type 2 1 0 1 2 0.079 0.039 0.039 0.079 Down Center Up Operating point (mm in) HYPR 0 0 35 1.378 30 1.181 25 0.984 20 0.787 15 0.591 10 0.394 5 0.197 Chemical / Oilresistant Semi-custom fibers 3 0.118 5 0.197 Vertical direction Retroreflective Type Fiber Options Fiber head 0 6 0.236 L H-SP 10 0.394 35 1.378 30 1.181 25 0.984 20 0.787 15 0.591 10 0.394 5 0.197 Setting distance L (mm in) Wide Beam 3mm 0.118in Transparent glass 200mm 7.874in (t=2.0mm) (t=0.079in) L FDA227 Horizontal direction Sleeve Convergent Reflective Type 5 0.197 FD-L22A Cylindrical Type Narrow Beam 4 2 0 2 4 0.157 0.079 0.079 0.157 Left Center Right Operating point (mm in) H-SP 10 0.394 STD 15 0.591 20 0.787 Setting distance L (mm in) 6 0.236 STD 15 0.591 Transparent glass 200mm, (t=2.0mm) 7.874in, (t=0.079in) HYPR Setting distance L (mm in) 0 Super Quality Small Spot Emitter H-SP 5 0.197 Fibers Flat Type L HYPR Setting distance L (mm in) 10 0.394 STD Setting distance L (mm in) Earlier models comparison table 15 0.591 Transparent glass 200mm, (t=2.0mm) 7.874in, (t=0.079in) HYPR Vertical direction Setting distance L (mm in) Horizontal direction 20 0.787 Setting distance L (mm in) Vertical direction 20 0.787 Setting distance L (mm in) How to read Model No Reflective type Horizontal direction Model Choose by shape/ application FD-L21W Reflective type Setting distance L (mm in) FD-L21 Fiber Selection Guide White non-glossy paper L Fiber head H-SP Left Right 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FDA240 300 11.811 HYPR 1,000 39.370 800 31.496 STD 600 23.622 400 15.748 200 7.874 0 300 11.811 White non-glossy paper L Fiber head H-SP Up Down 200 100 0 100 200 7.874 3.937 3.937 7.874 Down Center Up Operating point (mm in) FDA240 300 11.811 91 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. Vertical direction H-SP Left 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) STD L Fiber head H-SP 0 150 5.906 Left Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) FD-S32 Setting distance L (mm in) HYPR White non-glossy paper 500 19.685 L Fiberhead H-SP Left Right 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) FD-S33GW 400 15.748 FDA221 Setting distance L (mm in) L STD 400 15.748 Left Right H-SP 200 7.874 100 3.937 150 5.906 FDA236 100 3.937 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) 1,000 39.370 non-glossy paper 500 19.685 L Fiber head H-SP Up Down 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) STD 400 15.748 150 5.906 400 15.748 Fiber head Left STD 200 7.874 White non-glossy paper L Fiberhead H-SP Left 50 1.969 Right 25 0 25 0.984 0.984 Left Center Right Operating point (mm in) FDA221 50 1.969 White non-glossy paper 200 7.874 100 3.937 L Fiber head H-SP Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) 150 5.906 STD 400 15.748 White non-glossy paper L 0 150 5.906 150 5.906 Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options 600 23.622 200 7.874 Narrow Beam HYPR 800 31.496 Fiber head H-SP Semi-custom fibers Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) FDA219 150 5.906 Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type HYPR 400 15.748 Amplifiers STD White FX-500 series non-glossy paper 200 7.874 L Fiber head H-SP FX-100 series Up Down 0 50 1.969 STD Others 600 23.622 400 15.748 Cylindrical Type Sleeve 300 11.811 FDA219 Vertical direction HYPR Square Head Type Small Spot Reflective type FDA221 Super Quality 400 15.748 Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) FD-S60Y 600 23.622 White non-glossy paper Fibers Threaded Type HYPR 1,000 39.370 H-SP 0 60 2.362 Reflective type FDA257 Vertical direction L 200 7.874 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) Flat Type 150 5.906 HYPR 600 23.622 Up Down 0 150 5.906 800 31.496 Earlier models comparison table 500 19.685 Right Horizontal direction 0 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) H-SP FD-S32W FDA257 STD White White non-glossy paper Fiber head L Fiber head Left 1,000 39.370 0 400 15.748 White non-glossy paper How to read Model No. L Fiber head 50 1.969 600 23.622 200 7.874 Horizontal direction 600 23.622 0 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) H-SP White non-glossy paper 200mm 7.874in Reflective type FDA245 Vertical direction STD 0 150 5.906 60 2.362 FDA245 400 15.748 100 3.937 STD 100 3.937 60 2.362 HYPR 300 11.811 Choose by shape/ application 0 500 19.685 HYPR Reflective type HYPR Up Down Vertical direction STD 800 31.496 L 1,500 59.055 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) Model HYPR 150 5.906 Right Horizontal direction Fiber head 150 5.906 Fiber head FD-S31 White non-glossy paper H-SP White non-glossy paper 200mm 7.874in L Left 60 2.362 Reflective type FDA263 1,000 39.370 H-SP 600 23.622 STD 50 1.969 150 5.906 600 23.622 200 7.874 STD 100 3.937 0 HYPR 400 15.748 150 5.906 0 150 5.906 Horizontal direction 0 400 15.748 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) FDA263 1,500 59.055 Up Down Setting distance L (mm in) White non-glossy paper Setting distance L (mm in) Setting distance L (mm in) 600 23.622 200 7.874 L Fiber head H-SP 800 31.496 HYPR 400 15.748 White non-glossy paper Reflective type FDA216 Vertical direction FDA216 Horizontal direction 800 31.496 200 7.874 0 150 5.906 150 5.906 FD-S30 STD 400 15.748 Setting distance L (mm in) 0 150 5.906 Right 600 23.622 Setting distance L (mm in) L Fiber head 800 31.496 200 7.874 HYPR Setting distance L (mm in) White non-glossy paper 400 15.748 Setting distance L (mm in) STD 600 23.622 Setting distance L (mm in) Setting distance L (mm in) 800 31.496 200 7.874 HYPR Fiber Selection Guide Vertical direction Setting distance L (mm in) 1,000 39.370 HYPR Setting distance L (mm in) 1,000 39.370 Reflective type Horizontal direction Setting distance L (mm in) Horizontal direction 200 7.874 FD-S21 Reflective type Setting distance L (mm in) FD-R61Y 25 0 25 0.984 0.984 Down Center Up Operating point (mm in) FDA221 50 1.969 INDEX 92 SENSING CHARACTERISTICS (TYPICAL) New product introduction Tough Fiber Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. STD 100 3.937 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) 250 9.843 200 7.874 STD 150 5.906 100 3.937 50 1.969 Thru-beam Type White non-glossy paper 3.5mm L 0.138in Fiber head H-SP 20 10 0 10 20 0.787 0.394 0.394 0.787 Left Center Right Operating point (mm in) Setting distance L (mm in) HYPR 200 7.874 50 1.969 0 30 1.181 STD White non-glossy paper 30 1.181 1.2mm 0.047in H-SP Fiber head H-SP 100 3.937 200 7.874 H-SP 0 80 60 40 20 0 20 40 60 80 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 Left Center Right Operating point (mm in) FDA347 HYPR STD 200 7.874 H-SP White non-glossy paper 1.2mm L 0.047in Fiber head 0 80 60 40 20 0 20 40 60 80 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 Down Center Up Operating point (mm in) FDA347 L Fiber head STD 200 7.874 H-SP 100 3.937 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) 800 31.496 400 15.748 STD 200 7.874 H-SP White non-glossy paper L Fiber head 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) HYPR 2,500 98.425 600 23.622 400 15.748 STD 200 7.874 H-SP 1,000 39.370 60 2.362 4mm 0.158in L Fiber head 0 150 5.906 150 5.906 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) 150 5.906 FDA250 Reflective type White non-glossy paper L Fiber head STD H-SP 500 19.685 0 White non-glossy paper Vertical direction 2,000 78.740 1,500 59.055 60 2.362 HYPR FD-Z50HWFDA250 Reflective type FDA346 400 15.748 300 11.811 Vertical direction HYPR 3,000 118.110 STD 3.5mm 0.138in FDA249 Reflective type 600 23.622 150 5.906 30 1.181 20 0.787 White non-glossy paper HYPR 60 2.362 FDA249 Horizontal direction Horizontal direction HYPR 400 15.748 60 2.362 0 600 23.622 10 0 10 0.394 0.394 Down Center Up Operating point (mm in) 0 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) 800 31.496 400 15.748 Setting distance L (mm in) STD 200 7.874 Vertical direction Fiber head Fiber head 20 0.787 White non-glossy paper L 800 31.496 600 23.622 H-SP 20 0.787 Vertical direction Fiber head FDA436 Horizontal direction White non-glossy paper 4.0mm L 0.158in 40 1.575 0 20 0.787 White non-glossy paper 200mm 7.874in L STD FD-Z40HBW Setting distance L (mm in) Setting distance L (mm in) Others L 20 10 0 10 20 0.787 0.394 0.394 0.787 Down Center Up Operating point (mm in) FD-Z40W Reflective Type 60 2.362 FDA238 Reflective type HYPR 800 31.496 250 9.843 100 3.937 10 0 10 0.394 0.394 Left Center Right Operating point (mm in) 300 11.811 60 2.362 HYPR 150 5.906 L Fiber head 0 100 3.937 FDA239 Reflective type 300 11.811 20 0.787 HYPR 80 3.150 FD-Z20HBW FDA238 Fiber head 50 0 50 1.969 1.969 Down Center Up Operating point (mm in) Vertical direction 30 1.181 Retroreflective Type White non-glossy paper L 300 11.811 0 Fiber Dimensions INDEX STD 100 3.937 100 3.937 White non-glossy paper 200mm 7.874in H-SP 400 15.748 H-SP 0 40 1.575 STD Horizontal direction 300 11.811 100 3.937 60 2.362 20 0.787 HYPR 200 7.874 80 3.150 Setting distance L (mm in) Fiber head 100 3.937 Setting distance L (mm in) White L non-glossy paper Horizontal direction Setting distance L (mm in) Liquid Leak / Liquid Detection FX-100 series 400 15.748 Vertical direction HYPR 0 80 60 40 20 0 20 40 60 80 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 Down Center Up Operating point (mm in) FD-Z20W FDA239 Vacuumresistant FX-500 series Fiber head Vertical direction H-SP 100 3.937 White non-glossy paper 200mm 7.874in L Reflective type FDA237 HYPR 200 7.874 0 Heatresistant 300 11.811 Chemical / Oilresistant Amplifiers H-SP 50 1.969 Setting distance L (mm in) Setting distance L (mm in) 400 15.748 Retroreflective Type Semi-custom fibers 100 3.937 0 FDA237 Horizontal direction Sleeve Fiber Options STD FD-V50 Cylindrical Type Wide Beam 150 5.906 80 60 40 20 0 20 40 60 80 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 Left Center Right Operating point (mm in) Square Head Type Convergent Reflective Type L Fiber head 200 7.874 0 Threaded Type Narrow Beam 50 1.969 Super Quality Small Spot H-SP White non-glossy paper 200mm 7.874in HYPR Setting distance L (mm in) 100 3.937 Fibers Flat Type STD 100 3.937 Setting distance L (mm in) 150 5.906 Setting distance L (mm in) Earlier models comparison table HYPR Reflective type Horizontal direction Setting distance L (mm in) 200 7.874 250 9.843 Setting distance L (mm in) Choose by shape/ application Setting distance L (mm in) Model How to read Model No Vertical direction Horizontal direction 250 9.843 FD-V30W Reflective type Setting distance L (mm in) FD-V30 Fiber Selection Guide 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FDA241 60 2.362 3,000 118.110 HYPR 2,500 98.425 White non-glossy L paper Fiber head 2,000 78.740 1,500 59.055 1,000 39.370 STD H-SP 500 19.685 0 60 2.362 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) FDA241 60 2.362 93 PRECAUTIONS FOR PROPER USE *Never use this product as a sensing device for personnel protection. *In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Wiring *Make sure that the power supply is OFF while adding or removing the amplifiers. *Note that if a voltage exceeding the reted range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged. *Note that short-circuit of the load or wrong wiring may burn or damage the product. *Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction. *Verify that the supply voltage variation is within the rating. *If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. *In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. *Make sure to use the quick-connection cable (optional) for the connection of the controller. Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable. However, in order to reduce noise, make the wiring as short as possible. *Make sure that stress by forcible bending or pulling is not applied to the sensor cable joint and fiber cable. Refer to the "PRO mode operation manual" on our website for details. Others *Our products have been developed / produced for industrial use only. *The specification may not be satisfied in a strong magnetic field. *The ultra long distance (U-LG, HYPR) mode is more likely to be affected by extraneous noise since the sensitivity of that is higher than the other modes. Make sure to check the environment before use. *Do not use during the initial transient time (H-SP, FAST, STD: 0.5 sec., LONG, U-LG, HYPR: 1 sec.) after the power supply is switched ON. *These sensors are only for indoor use. *Avoid dust, dirt, and steam. *Make sure that the product does not come in contact with oil, grease, organic solvents such as thinner, etc., strong acid or alkaline. *This product cannot be used in an environment containing inflammable or explosive gases. *Never disassemble or modify this product. *This product adopts EEPROM. Settings cannot be done a million times or more because of the EEPROM's lifetime. New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 94 New product introduction Tough Fiber PRECAUTIONS FOR PROPER USE Abstract from "PRO MODE OPERATION MANUAL" Part description Symbol explanation SET SET key (Confirm) : Press the SET key. UP (+) key (Select) Fiber Selection Guide Model Choose by shape/ application Response time SET setting (Note 1) 250s or less +, - SET 2ms or less +, - 4ms or less +, - +, +, 25s or less Response time Fibers " ", " " " " ", " ", " " OFF-delay timer +, - ON-delay timer +, - Flat Type +, - Sensing output 2 +, - External input +, - "ms" Approx. 0.5ms, Approx. 1 to 9,999ms Approx. 0.5 sec., Approx. 1 to 32 sec. Input / output setting SET SET Copy setting YES SET Large +, - Copy action setting Convergent Reflective Type Automatic SET Display adjustment Copy lock setting Displayed in percentage SET +, - Incident light intensity (Note 3) Response time " ", " " " " ", " ", " " Max. 4,000 +, - Vacuumresistant Liquid Leak / Liquid Detection Max. 9,999 Copy lock OFF +, - Copy lock ON SET Communication mode +, - Communication emission halt Only displayed in FX-502 or FX-505-C2 SET SET External input setting (Note 6) Correcting SET Only one unit SET Timer range setting Semi-custom fibers +, Copy lock 1/10ms +, - Teaching lock SET setting SET All SET +, - Retroreflective Type Setting items in digital display setting SET +, - +, - Data bank save Data bank load +, - Emission OFF +, - Teaching +, - Lock ON Limit + +, - Reflective Type Incident light intensity +, - +, - Displayed in percentage +, - Peak / bottom value SET Turning OFF +, - SET Eco OFF +, - Turning ON +, ECO setting Limit - +, - +, - Data bank save Data bank load +, - Notes: 6) The signal input time from outside is as follows. Eco ON +, - Full +, +, - +, Time period hold setting (Note 5) Display adjustment +, - +, Setting of digital display turning Others SET Hold OFF +, - Hold ON Notes: 5) In order to clear the value, set the time period holding function to OFF once. Turning the power OFF can also clear the value. INDEX Logic setting +, - Thru-beam Type FX-100 series Lock OFF +, - +, - Display adjustment +, sec. +, - Limit - +, - " when the Notes: 4) In case the response time setting is set to " hysteresis setting is " " , the emitting power becomes low sensibility (" ") whichever selecting " ", " " or " ". ms +, - Limit + +, - SET High emission power +, - Middle emission power +, - Low emission power SET Teaching +, - +, +, - Emission OFF +, - +, - Automatic Automatic In case saturation correction is NG, it is not displayed. +, - SET +, - Max. 8,000 " Saturation correction SET Fiber Options Display adjustment OFF Incident light intensity +, - Emission power setting (Note 4) Display copy +, - +, Communication protocol setting Notes: 3) Incident light intensity setting depends on the response times. Chemical / Oilresistant FX-500 series +, - Small +, - Retroreflective Type Heatresistant good Automatic +, - 2 turns +, - Approx. 0.05ms, Approx. 0.1 to 999.9ms +, Shift amount setting Blinks 3 times Only displayed in FX-502 +, - Wide Beam good +, - Blink Back up OFF SET Blinks 3 times +, - "sec." Standard +, - SET Back up ON Timer period "1/10ms" +, - YES 1 ch +, - +, - +, - Timer range Narrow Beam +, - ON / OFF-delay ON-delay / One-shot timer One-shot timer timer (Except sensing output 2) (Except sensing output 2) Notes: 2) When using time, be sure to set the time range. Since the setting time depends on timer range as table below, set the setting time after selecting the timer range. Sleeve Hysteresis setting Back up setting +, +, - Small Spot +, - Max. 9,999 good +, - Blink Changeable 1 to Automatic 8ch in + or - Max. 4,000 +, - Square Head Type Changeable 1 to Automatic 8ch in + or - Data bank saving setting SET Max. 8,000 YES 1 ch +, - SET +, - 24ms or less Incident light intensity " No timer +, - SET Threaded Type Cylindrical Type Data bank SET loading setting Notes: 1) Display of incident light intensity depends on the response time. +, - Timer setting +, +, - 60s or less Super Quality Automatic : Automatically move to next MODE indicator: PRO (Yellow) PRO mode Earlier models comparison table Amplifiers : Press the UP (+) key or DOWN (-) key. MODE key (Select, cancel) How to read Model No Fiber Dimensions +, - DOWN (-) key (Select) Input time 2 point teaching Limit teaching Display adjust Full auto teaching Emission OFF, Logic setting Copy lock Data bank loading Data bank saving 20 to under 500ms 600ms or more (sampling during input) 2ms or more (conducted during inputting) Input pulse of the specified channel number (1 pulse: 16 to 300ms). However, the pulse cycle is under 500ms. ( 95 PRECAUTIONS FOR PROPER USE New product introduction Tough Fiber Abstract from "PRO MODE OPERATION MANUAL" ion y. key or Fiber Selection Guide ve to next Model +, good SET Code setting Choose by shape/ application +, - Blinks 3 times SET SET Logic operation setting SET Between adjacent amplifier SET Invalid +, - and Earlier models comparison table +, +, Display adjustment setting SET good Target setting (Note 7) Confirm +, - OFF +, - Blinks 3 times xor Between external input SET Display 0 SET adjustment setting Target setting SET Confirm Confirm Confirm Response time ", " " +, +, - Reset setting y ment OFF "," " " " ", " " Setting of threshold Setting of threshold value tracking SET tracking cycle SET Blink Emission power setting +, - Sensing output setting SET Hysteresis setting or 1 sec. OFF +, - Default Storage cycle setting OFF +, - ON OFF +, - 1 time +, Limit teaching +, - Auto teaching Different frequency setting SET Emission frequency 1 +, - Emission frequency 2 +, - Teaching Emission frequency 3 +, Limit + +, - (Note 8) SET Window comparator mode Rising differential Trailing differential Normal mode +, - (Except sensing output 2) +, - mode (Note 9) +, - mode (Note 9) Limit - +, - +, - Forced OFF output mode +, - +, +, Forced ON output mode bank Hysteresis mode In case FX-502 or FX-505-C2, by pressing down MODE key long time, sensing output 1 or 2 can be changed to another. ic setting +, - +, - (The following diagram shows in selecting the window comparator mode.) Limit + Shift amount setting SET (Displayed in percentage) SET +, +, - Limit - +, - SET SET +, - +, - Shift amount setting (Note 11) bank Notes: 8) : Set the sensing output setting after input / output setting for FX-502. 9) In case using in differential mode, set threshold value 20 or more when the hys" and set threshold value 80 or more when the hysteresis teresis setting is " setting is " " or " ". 10) After external input, the time given until an answer back output is as follows. However, in case timer of the sensing output 2 is valid, the output time is different from the following table. ng) number ms. Input time After 20ms from the input end, the answer back output is read out when result of the teaching is " ". After 20ms from the input end, the answer back Display adjust output is read out. After 520ms from rising of last input pulse, the anData bank loading swer back output (pulse) of the number of channel in Data bank saving the data bank is read out. 11) Incident light intensity depends on the response time as table below. 2 point teaching Limit teaching Full auto teaching Response time " ", " " " " ", " ", " Shift direction Sensing output ON Light-ON - Sensing output ON Dark-ON + Sensing output OFF Light-ON + Sensing output OFF Dark-OFF - Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series Incident light intensity " Max. 4,000 Max. 8,000 " Sensing output status Sensing output operation Convergent Reflective Type Self-diagnosis output mode (Except sensing output 1) Answer back output mode (Note 10) (Except sensing output 1) +, - Narrow Beam +, Only displayed in FX-502 or FX-505-C2 Only displayed in FX-505-C2 Teaching +, - ", conduct the limit teaching for the Notes: 12) In case setting to " changed incident light intensity. Shift direction of the threshold differs depending on the combination of the sensing output status and the sensing output operation. +, - Flat Type Wide Beam SET Algorithm setting (Note 12) SET +, - Sleeve Small Spot +, +, - +, - +, Interference prevention setting SET Cylindrical Type +, - +, - Blinks 3 times +, Response time setting +, - Square Head Type +, xor +, - From -1,999 to 9,999 Automatic SET CUSTOM setting SET and From -1,999 to 4,000 From -1,999 to 8,000 SET Threaded Type +, - Target setting " Invalid +, +, - Notes 7) Target setting of display adjust setting depends on the response time as table below. good or xor Between sensing output 1 and sensing output 2 SET - Fibers Super Quality +, +, - +, - SET SET SET and Invalid +, +, - +, - Incident light intensity or Only displayed in FX-502 or FX-505-C2 +, - +, - +, +, - +, - How to read Model No. Max. 9,999 INDEX 96 New product introduction Tough Fiber FX-501(P)FX-502(P) Output selection indicator (Yellow) (Note 1) Fiber Selection Guide Model Choose by shape/ application Fibers Super Quality Cylindrical Type 8.2 0.323 Beamemitting part 27.8 1.094 22.7 0.894 32 1.260 28 20.8 1.102 0.819 7 0.276 Beamreceiving part Output selection indicator (Yellow) MODE key Setting switch Communication window 10 0.394 FX-505-C2FX-505P-C2 8.2 0.323 Amplifier 62.5 2.461 2 0.079 9.95 0.392 MODE key Output 1 operation indicator (Orange) Output 2 operation indicator (Orange) (Note 1) 24 0.945 36.5 1.437 3 75 2.953 0.118 Suitable for 35 mm 1.378 in width DIN rail Output 2 operation indicator (Orange) Digital display (Green / Red) 10 Beam- 0.394 emitting part Setting switch 27.8 1.094 22.7 0.894 7 0.276 1.1 0.043 7 0.276 10.5 0.413 5.7 0.224 Threaded Type Square Head Type Amplifier 9.95 62.5 2.461 0.392 2 0.079 Digital display (Green / Red) Output 1 operation indicator (Orange) (Note 2) How to read Model No Earlier models comparison table Refer to p.48 ~ for details of fiber dimensions. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) Communication window o4 o0.157 cable 2 m 6.562 ft 32 28 1.260 1.102 20.8 7 0.276 0.819 Beamreceiving part 10.5 0.413 9.2 0.362 5.7 0.224 24 0.945 3 0.118 3.95 0.156 (Note 3) 36.5 1.437 3.95 0.156 2.8 0.110 75 2.953 Suitable for 35 mm 1.378 in width DIN rail Notes: 1) FX-502(P) only 2)FX-501(P): Operation indicator 3)FX-501(P): 3-pin, FX-502(P): 4-pin Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type CN-73-CCN-74-C *Length L Length L CN-73/74-C1 1,000 39.370 CN-73/74-C2 2,000 78.740 CN-73/74-C5 5,000 196.850 Vacuumresistant Liquid Leak / Liquid Detection Fiber Options (Note 1) 2.65 0.104 14 (0.551 ) 2.9 (0.114 ) 2.54 0.100 Notes: 1) CN-74-C only 2) CN-73-C: 3-core 7 0.276 10 0.394 13.6 0.535 3 0.118 21.6 0.850 16 0.630 5.2 0.205 Reflective Type 0.4 0.016 o1.8 o0.071 7.5 0.295 4.2 0.165 35 1.378 2 0.079 2 0.079 2-o3.2 o0.126 holes Material: C old rolled carbon steel (SPCC) (Uni-chrome plated) FX-500 series FX-100 series INDEX 1,000 39.370 CN-71/72-C2 2,000 78.740 CN-71/72-C5 5,000 196.850 14 (0.551 ) 2.54 0.100 3 0.118 2.9 (0.114 ) 2.54 0.100 0.2 0.008 7 0.276 10 0.394 13.6 0.535 MS-DIN-E 3 0.118 5 0.197 15 0.591 60 2.362 3 0.118 5.6 M3 square nut 0.220 24.7 0.972 1.6 0.063 ( ) 7.2 0.283 End plate (Optional) M3 (length 18 mm 0.709 in) pan head screws 3 0.118 10 0.394 6 0.236 12 10.5 (0.472 ) 0.413 2.65 0.104 7.2 0.283 50 1.969 o3.3 o0.130 cable 2.75 0.108 3.2 0.126 t1 t 0.039 27 1.063 (Note 2) Notes: 1) CN-72-C only 2) CN-71-C: 1-core 5.2 0.205 Others Amplifiers CN-71/72-C1 10 0.394 3.2 0.126 L Length L ( ) Amplifier mounting bracket (Optional) Fiber Dimensions Retroreflective Type Sub cable (Optional) Model No. (Note 1) 0.2 0.008 8.5 0.335 Thru-beam Type 10 0.394 6 0.236 12 10.5 (0.472 ) 0.413 MS-DIN-2 Semi-custom fibers (Note 2) 50 1.969 o3.3 o0.130 cable 2.54 0.100 Chemical / Oilresistant CN-71-CCN-72-C *Length L L Model No. Retroreflective Type Heatresistant Main cable (Optional) 32 1.260 Material: Polycarbonate 4 0.157 Suitable for 35 mm 1.378 in width DIN rail 97 98 New product introduction Tough Fiber Fiber Selection Guide Digital Fiber Sensor FX-100 SERIES Taking fiber sensors to the next level Model Choose by shape/ application How to read Model No Conforming to EMC Directive Listing Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type * The FX-100 series has been changed to Panasonic brand from production in and after July 2011. * Cover opened state is shown. Small Spot PNP output type available Timer Automatic sensitivity setting Test input Interference Light intensity monitor prevention Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Good dual digital display The threshold value and incident light intensity can be both confirmed at the same time, bringing good operability when making changes of each setting. Threshold value Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Commercially-available connectors reduce lead time and spare part numbers Compatible with commercially-available connectors, so that processing costs and lead time required for processing after purchase can be greatly reduced. The connection parts same as the DP-100 series digital pressure sensors and the PM-64 series micro photoelectric sensors can be commonly used. Reflective Type Conventional (cable type) FX-500 series FX-100 series INDEX Conventional lead time Harness processing by outside order is needed after sensor preparation. Customer Purchase and preqaration of sensor Harness processing by outside order Sensor installation Sensor preparation Harness processor From now on (built-in connector type) Others Amplifiers Commercially-available connector Commercially-available crimping connectors are used, so that the processing costs for connection cables can be greatly reduced. Thru-beam Type Retroreflective Type Incident light intensity Sensor installation Harness processing Lead time from now on Harness processing can be done by outside order at the same time of sensor preparation. No need junction connector. Customer Sensor preparation Sensor installation Purchase and preqaration of sensor Harness processing by outside order Sensor installation Harness processor Using cables with connectors Harness processing Lead time further reduced Harness processing by outside order is not needed. Lead time and spare part numbers can be reduced. Purchase and preqaration of sensors and cable with connectors Sensor installation Customer Reduced Sensor preparation Sensor installation Reduced Reduced lead time 99 Saving-space with a width of 9 mm 0.354 in Improved stability over long terms Very slim body at only 9 mm 0.354 in. This is much thinner than existing fiber sensors. This makes a very large difference when using many units, even if the difference of one unit is small. Utilizes "Four-chemical emitting element" for light emission. The light emission is guaranteed to be stable over long periods of time. [Stable sensing comparison] Light-emitting amount 9 mm 0.354 in FX-100 Three-chemical emitting element Incident light intensity Threshold value Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No. Long-term stability Earlier models comparison table Time Simple operation due to clear configuration system Fibers Continued to use the configuration system of digital pressure sensor DP-100 series, which has received high popularity since its release. We have separated the settings into three levels: RUN mode, SET mode, and PRO mode, making operation simpler and easier. Functions used during normal operation RUN mode * Changing threshold values * Key lock * Quick settings * Code settings Functions used when initializing the sensor and carrying out maintenance Simple setting SET mode * Teaching * L-ON / D-ON setting * Timer setting * Emission amount * Emission frequency setting Equipped with a full complement of digital fiber sensor functions PRO mode * Shift setting * Reset * ECO * Threshold value margin * Threshold value follow-up cycle Special and detailed setting * External input * GETA * Inverting display * Copy Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Quick code input function Simply imputing the default setting "code (number)" will enable sensor settings. Even if the settings are accidentally changed, imputing the code will restore the default settings. Confirmation can be carried out smoothly via telephone by simply quoting numbers. This can be of great assistance when dealing with foreign country customers. New product introduction RUN mode Fiber Options Quick setting: Press and simultaneously for 2 sec. Code setting: Press and simultaneously for 4 sec. Semi-custom fibers Fiber Dimensions Quick setting numbers (abstract) No Output operation Timer Emission amount setting Thru-beam Type Retroreflective Type Dark-ON None OFF Dark-ON None ON Reflective Type Dark-ON OFF-delay 10 ms OFF Others Dark-ON OFF-delay 10 ms ON Light-ON ON-delay 40 ms ON Light-ON ON-delay 40 ms OFF Amplifiers Light-ON ON-delay 10 ms ON FX-500 series Light-ON ON-delay 10 ms OFF FX-100 series Refer to "Quick setting function" and "Code setting function" in "PRECAUTIONS FOR PROPER USE" for details. INDEX 100 100 New product introduction Tough Fiber Fiber Selection Guide Model Teaching with ON / OFF keys SET mode Simply press the ON key when an object is present, and OFF when it is not, and teaching is completed. There is no need to consider difference between Light-ON and Dark-ON. Thru-beam type / Retroreflective type Choose by shape/ application Resolves variation in incident light intensity display PRO mode GETA function Even when performing the same sensing operation, there may be variances in the digital values of the fiber amp. There is no problem with the sensor itself, but the operator may find it troubling. Given value can be corrected with the GETA function, so the apparent variation can be eliminated and the creation of operation manuals can proceed smoothly. How to read Model No Earlier models comparison table Variations in the amount of light received Object present ON Object absent OFF Fibers Super Quality Reflective type Unify at 500 using the GETA function Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Object present ON Object absent OFF Small Spot Narrow Beam Example of current incident light intensity display of ` ' adjusted to ` Chemical / Oilresistant Heatresistant Vacuumresistant 4,000 [digits] 500 current value 0 500 Not displayed Liquid Leak / Liquid Detection Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX PRO mode This function performs automatic setting to threshold value by checking the incident light intensity at desired intervals in order to follow the changes in the light amount resulting from changes in the environment over long periods (such as dust). Contributes to reduction in maintenance hours. * Effective when the output operation is set to Dark-ON, and when using thru-beam type or retroreflective type fibers. Current value Incident light intensity when an object is absent. A 4000 Actual digit difference: C Upper display limit Light emitting amount decreased B Time SET mode Emission amount can be reduced in order to achieve stable detection when the receiving light level is saturated, such as detection at close range and detection of transparent or minute objects. Previously, the emission amount level was only one, but from production in December 2007, four level setting (three level + auto setting) has become available. This function brings easier settings than before. Light receiving level saturated Threshold value 0 Emission amount setting function Incident light intensity Semi-custom fibers Threshold value follow-up cycle setting function Incident light intensity Fiber Options Because the original value is 500, sensor displays 500 for the lower limit value and 4,000 for the upper limit value. 1,000 Saturated digit difference: D Stable sensing Incident light intensity Retroreflective Type Teaching even without an object -- Limit teaching function Threshold value can be set by performing teaching only when an object is absent (when the incident light amount is stable). This is useful when there are other objects in the background also when defecting a minute objects. Teaching can also be carried out using external input. 4,000 [digits] Incident light intensity Wide Beam Convergent Reflective Type ' is , A , B Actual digit difference: C 101 101 Emission frequency setting mode SET mode Mutual interference is prevented for max. 3 units for standard type FX-101 and max. 4 units in case of long sensing range type FX-102. During setting of interference prevention, emitter and output indicator both flash, so it is convenient to confirm which fiber is in the setting process at a glance. Emitter flashes even when an amplifier is not installed close together. * When the emission frequency is changed, a response time is also changed. Setting copy function to reduce man-hours PRO mode and human error By connecting a fiber sensor to the master fiber sensor, the master sensor settings can be copied along with data communications. When the same settings are input to several units, trouble from setting errors can be prevented, also changes to the work order will be small when equipment design is changed. Color of lead wire of attached connector cable (Black) Output + - (White) External input External input setting mode PRO mode External input can be selected from emission halt, limit teaching / full-auto teaching / 2-level teaching, ECO or emission amount test. Threshold value set at each teaching is also memorized. * 2-level teaching, emission amount test and threshold value storing setting are available in amplifiers manufactured after December 2007. Color of lead wire of attached connector cable (Brown) +V (White) External input Super Quality (Black) Output (White) External input Threaded Type (Blue) 0 V Square Head Type These settings can be copied Threshold value, output operation, timer operation, timer emission amount, shift, external input, threshold valuestoring, ECO inverting digital display, and threshold value margin PLC etc. (Blue) 0 V External input lines are equipped as standard Without mounting bracket Sleeve Flat Type Small Spot Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Digital display inversion setting PRO mode Vacuumresistant The viewing orientation of the digital display can be inverted in accordance with the setting direction of the amplifier. Previous products (without inversion function) Cylindrical Type Narrow Beam Selectable either mounting on DIN rail or direct mounting with through hole. Direct mounting brings stability even on a movable parts or installation of a single unit. (Black) Output How to read Model No. Fibers (Brown) +V The emitter and output indicator flash at the same frequency. Model 12 to 24 V DC 10 % (Blue) 0 V Slave side Fiber Selection Guide Earlier models comparison table (Brown) +V Copy Tough Fiber Choose by shape/ application Master side New product introduction Liquid Leak / Liquid Detection FX-100 SERIES o3.2 mm 0.126 in mounting holes Fiber Options Can be mounted with M3 screws. Turn OFF Available from standard type or long sensing range type Turn ON Alert function PRO mode When the amount light received approaches the threshold value, the display can be made to blink in order to alert the operator. Incident light intensity The amount of light received ranges from about 900 to 1,100 when the digital indicator flashes. Range of the digital indicator flashing (margin: small) 1,100 approx. 900 approx. The digital indicator flashes. Semi-custom fibers Threshold value of 1,000 Standard type and long sensing range type are available which has various response time and sensing range. The model best meet application needs can be selected. Model No. Type Sensing range (FT-B8) Response time FX-101 Standard type 400 mm 15.748 in Max. 250 s FX-102 Long sensing range type 1,150 mm 45.276 in Max. 2.5 ms Power consumption saving with ECO mode Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers ECO When there is no key operations in approximately 20 seconds, digital display turns off and power consumption can be reduced to 600mW or less (720mW in normal mode). FX-500 series FX-100 series INDEX 102 102 New product introduction Tough Fiber ORDER GUIDE Amplifiers Type Appearance Fiber Selection Guide M8 plug-in connector type Earlier models comparison table Cable set (Note 1) How to read Model No Standard type Choose by shape/ application M8 plug-in connector type Model Fibers Super Quality Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection M8 plug-in connector type M8 plug-in connector type Cylindrical Type Cable set (Note 1) Square Head Type Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type NPN open-collector transistor FX-101-Z (Note 3) NPN open-collector transistor FX-101P (Note 2) PNP open-collector transistor FX-101P-Z (Note 3) PNP open-collector transistor FX-101-CC2 NPN open-collector transistor FX-101P-CC2 PNP open-collector collector transistor FX-102 (Note 2) NPN open-collector transistor FX-102-Z (Note 3) NPN open-collector transistor FX-102P (Note 2) PNP open-collector transistor FX-102P-Z (Note 3) PNP open-collector transistor FX-102-CC2 NPN open-collector transistor FX-102P-CC2 PNP open-collector transistor Accessory *CN-14A-C2 Connector attached cable 2 m 6.562 ft *Only include cable set type *FC-FX-1 (Protection cover) *It have been attached from the production at July, 2011. Notes: 1) The connector attached cable 2 m CN-14A-C2 is supplied with the amplifier. 2) M ake sure to use the optional connector attached cable CN-14A(-R)-C or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd. (contact: SPHD-001T-P0.5, housing: PAP-04V-S) 3) Make sure to use the optional M8 connector attached cable CN-24A-C. OPTIONS Designation Model No. Description 1 m 3.281 ft CN-14A-C2 (Note) 2 m 6.562 ft CN-14A-C3 3 m 9.843 ft CN-14A-C5 5 m 16.404 ft CN-14A-R-C1 1 m 3.281 ft CN-14A-R-C2 2 m 6.562 ft CN-14A-R-C3 3 m 9.843 ft CN-14A-R-C5 5 m 16.404 ft M8 connector attached cable CN-24A-C2 2 m 6.562 ft CN-24A-C5 5 m 16.404 ft Connector CN-14A Set of 10 housings and 40 contacts Connector attached cable Connector attached cable (Flexible type) Amplifier MS-DIN-4 mounting bracket End plates MS-DIN-E Two pcs. per set M8 connector attached cable *CN-24A-C 31.4 1.236 CN-14A-C1 Fiber Options Semi-custom fibers Output FX-101 (Note 2) Red LED Long sensing range type Threaded Type Emitting element Model No. 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: o3.7 mm o0.146 in o9 o0.354 o4 o0.157 M8 connector attached cable CN-24A-C Fixing ring For M8 plug-in connector type The connector on one end Cable outer diameter: o4 mm o0.157 in Amplifier mounting bracket *MS-DIN-4 Mounting bracket for amplifier When it moves depending on the way it is installed on a DIN rail, these end plates ensure that all amplifiers are mounted together in a secure and fully connected manner. Others Note: The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10-CC2. Amplifiers Recommended connector Connector attached cable *CN-14A(-R)-C FX-500 series FX-100 series Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Connector *CN-14A Contact Recommended crimping tool INDEX Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Housing 103 103 SPECIFICATIONS Model No. Type Item New product introduction Standard type Long sensing range type Cable set Cable set NPN output FX-101(-Z) (Note 5) FX-101-CC2 FX-102(-Z) (Note 5) FX-102-CC2 PNP output FX-101P(-Z) (Note 5) FX-101P-CC2 FX-102P(-Z) (Note 5) FX-102P-CC2 Supply voltage Power consumption Output 12 to 24 V DC 10 % Ripple P-P 10 % or less Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) NPN open-collector transistor PNP open-collector transistor * Maximum sink current: 100 mA * Maximum source current: 100 mA * Applied voltage: 30 V DC or less (between output and 0 V) * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.5 V or less (at 100 mA sink current) * Residual voltage: 1.5 V or less (at 100 mA source current) Output operation Response time Environmental resistance Ambient temperature 3-level + Auto setting (from production in December 2007) Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2, 3 or 4) -10 to +55 C +14 to +131 F (If 4 to 7 units are mounted close together: -10 to +50 C +14 to +122 F, if 8 to 16 units are mounted close together: -10 to +45 C +14 to +113 F) (No dew condensation or icing allowed), Storage: -20 to +70 C -4 to +158 F Incandescent light: 3,000 x at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3) Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3) Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Emitting element (modulated) Red LED (Peak emission wavelength: 643 nm 0.025 mil) Material Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT Connecting method Cable length Weight Accessory Cylindrical Type Sleeve Flat Type Small Spot Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Voltage withstandability Square Head Type Wide Beam ON-delay / OFF-delay timer, switchable either effective or ineffective [Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2 or 3) Threaded Type Convergent Reflective Type Incorporated Ambient humidity Earlier models comparison table Narrow Beam 4 digits (green) + 4 digits (red) LCD display Emission amount setting function Interference prevention function Emission frequency 1: 2.5 ms or less (factory default setting) Emission frequency 2: 2.8 ms or less Emission frequency 3: 3.2 ms or less Emission frequency 4: 5.0 ms or less Orange LED (lights up when the output is ON) Fine sensitivity adjustment function Timer function How to read Model No. Super Quality PNP non-contact input * Signal condition High: +4 V to +V DC (Sink current 0.5 to 3 mA) Low: 0 to +0.6 V DC or Open * Input impedance: 10 k approx. 2-point teaching / Limit teaching / Full-auto teaching Digital display Choose by shape/ application Incorporated Emission frequency 0: 250 s or less (factory default setting) Emission frequency 1: 450 s or less Emission frequency 2: 500 s or less Emission frequency 3: 600 s or less Operation indicator Model Fibers NPN non-contact input * Signal condition High: +8 V to +V DC or Open Low: 0 to +2 V DC (Source current 0.5 mA or less) * Input impedance: 10 k approx. Sensitivity setting Fiber Selection Guide Selectable either Light-ON or Dark-ON, at SET mode Short-circuit protection External input Tough Fiber Connector (Note 4) Total length up to 100 m 328.084 ft is possible with 0.3 mm , or more, cable. 2 Net weight: 15 g approx. Gross weight: 35 g approx. Net weight: 15 g approx. Gross weight: 75 g approx. Net weight: 15 g approx. Gross weight: 35 g approx. FC-FX-1 (Protection cover): 1 pc. (Note 6) FC-FX-1 FC-FX-1 (Protection cover): 1 pc. (Note 6) CN-14A-C2 (Protection cover): 1 pc. (Note 6) (Connector attached cable, 2 m 6.562 ft long): 1 pc. Net weight: 15 g approx. Gross weight: 75 g approx. FC-FX-1 (Protection cover): 1 pc. (Note 6) CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values. However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2. 3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. 4) Connector attached cable CN-14A-C2 is not attached to the models that have no "-CC2" at the end of the model Nos. Make sure to use the optional connector attached cable CN-14A(-R)-C or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd. (contact: SPHD-001T-P0.5, housing: PAP-04V-S). 5) Model Nos. having the suffix "-Z" are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C. 6) Protection cover FC-FX-1 has been attached from production in July, 2011. Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 104 104 I/O CIRCUIT AND WIRING DIAGRAMS New product introduction Tough Fiber FX-10(-Z/-CC2) NPN output type I/O circuit diagram Terminal arrangement diagram Fiber Selection Guide Terminal No. Model How to read Model No Earlier models comparison table 1 D Sensor circuit Choose by shape/ application +8 V 2 Tr Threaded Type Square Head Type Cylindrical Type 3 Small Spot Narrow Beam Wide Beam Convergent Reflective Type Semi-custom fibers Output 3 External input 4 M8 plug-in connector type Terminal No. 1 or 3 Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Function +V 2 Output External input 4 0V High (+8 V to +V DC, or open): Ineffective Low [0 to +2 V DC (source current 0.5 mA or less)]: Effective FX-10P(-Z/-CC2) PNP output type I/O circuit diagram Terminal arrangement diagram Terminal No. Connector type Color code of cable with connector 1 3 D *1 (White) External input ZD Tr Terminal No. (Brown) +V 100 mA max. 2 4 (Black) Output (Blue) 0 V Load + - 12 to 24 V DC 10 % Function +V 1 2 Output 3 External input 4 0V Users' circuit Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor M8 plug-in connector type Terminal No. 1 *1 Non-voltage contact or PNP open-collector transistor Fiber Dimensions 0V Users' circuit Internal circuit Fiber Options *1 (Blue) 0 V 2 Non-voltage contact or NPN open-collector transistor Sensor circuit Liquid Leak / Liquid Detection 12 to 24 V DC 10 % *1 Chemical / Oilresistant Vacuumresistant + - Function +V 1 (White) External input Retroreflective Type Heatresistant Load Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor Sleeve Flat Type (Black) Output Internal circuit Fibers Terminal No. (Brown) +V 100 mA max. ZD 4 Super Quality Connector type Color code of cable with connector or High [ +4 V to +V DC (sink current 0.5 to 3 mA)]: Effective Low (0 to +0.6 V DC, or open): Ineffective 3 Function +V 2 4 Output External input 0V 105 105 SENSING CHARACTERISTICS (TYPICAL) FT-31W 250 9.843 100 3.937 200 100 0 100 200 7.874 3.937 3.937 7.874 Left Center Right Operating point (mm in) FT-43 Parallel deviation 0 100 3.937 800 31.496 600 23.622 FX-101 Fiber head 400 15.748 L Fiber head 200 7.874 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) FT-S21W 150 5.906 FX-101 100 3.937 Fiber head 50 1.969 L Fiber head 400 15.748 FX-101 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) 100 3.937 400 15.748 Fiber head L Fiber head 0 Sensing field * Horizontal direction 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) 400 15.748 FX-101 L Fiber head Left 0 20 0 20 0.787 0.787 Left Center Right Operating point (mm in) FDA269 Right 40 1.575 Setting distance L (mm in) White non-glossy paper 200mm 7.874in FX-102 White non-glossy paper 200mm 7.874in 100 3.937 50 1.969 0 40 1.575 1,000 39.370 L Fiber head 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) FX-101 L Fiber head Up Down 20 0 20 0.787 0.787 Down Center Up Operating point (mm in) FDA269 200 0 200 7.874 7.874 Left Center Right Operating point (mm in) L Fiber head Left Right FX-102 100 3.937 FX-101 50 1.969 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FD-41W 40 1.575 8mm 0.315in L Fiber head 200 0 200 7.874 7.874 Down Center Up Operating point (mm in) 60 2.362 400 15.748 FX-102 100 3.937 FX-101 7.874in Left 40 1.575 Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Right Fiber Options 50 1.969 Semi-custom fibers 20 0 20 0.787 0.787 Left Center Right Operating point (mm in) 40 1.575 Fiber Dimensions FDA273 Reflective type Thru-beam Type Retroreflective Type Reflective Type * Vertical direction 200 7.874 200 7.874 FX-102 FX-101 White non-glossy paper 200mm 7.874in L Fiber head 50 1.969 Left 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FDA266 200mm L Fiber head 150 5.906 FDA272 100 3.937 White non-glossy paper 200 7.874 250 9.843 60 2.362 Small Spot Fiber head 1,000 39.370 250 9.843 0 Flat Type 2,000 78.740 0 Threaded Type Sleeve FX-101 250 9.843 Super Quality Cylindrical Type Reflective type FD-32GX FTA237 White non-glossy paper 200mm 7.874in Fibers Square Head Type Sensing field 150 5.906 150 5.906 400 15.748 FX-102 0 400 15.748 400 15.748 Reflective type FTA237 200 7.874 60 2.362 150 5.906 FX-102 Fiber head Sensing field * Horizontal direction * Vertical direction 150 5.906 2,000 78.740 0 FTA231 Reflective type FTA232 400 15.748 3,000 118.110 250 9.843 200 7.874 0 * Vertical direction Sensing field 600 23.622 Earlier models comparison table 4,000 157.480 FD-32G FX-102 L Thru-beam type FTA229 FX-101 0 400 15.748 1,000 39.370 Setting distance L (mm in) Setting distance L (mm in) Setting distance L (mm in) 500 0 500 19.685 19.685 Left Center Right Operating point (mm in) Parallel deviation FX-102 FD-41S Setting distance L (mm in) L Fiber head How to read Model No. Fiber head FTA234 Parallel deviation * Horizontal direction 800 31.496 200 7.874 40 1.575 Fiber head 200 7.874 FT-A11 Thru-beam type FT-S31W FTA236 250 9.843 50 1.969 Fiber head Choose by shape/ application FX-101 400 15.748 600 23.622 3,000 118.110 FX-101 Model FX-102 600 23.622 FX-102 FX-102 200 7.874 0 1,000 39.370 Thru-beam type FTA233 Parallel deviation 100 3.937 600 400 200 0 200 400 23.622 15.748 7.874 7.874 15.748 Left Center Right Operating point (mm in) 4,000 157.480 400 15.748 1,000 39.370 L Fiber head 0 100 3.937 Setting distance L (mm in) 600 23.622 100 3.937 50 0 50 1.969 1.969 Left Center Right Operating point (mm in) Thru-beam type FTA230 Parallel deviation Setting distance L (mm in) Setting distance L (mm in) FX-102 800 31.496 0 Fiber head 200 7.874 1,000 39.370 1,000 39.370 1,000 39.370 L Fiber head FX-101 400 15.748 FT-45X 1,200 47.244 0 50 1.969 300 11.811 Thru-beam type FTA235 Fiber head 600 23.622 Setting distance L (mm in) 300 11.811 L Fiber head FX-101 100 3.937 FX-102 Setting distance L (mm in) Fiber head 150 5.906 Tough Fiber Fiber Selection Guide 800 31.496 800 31.496 Setting distance L (mm in) FX-101 200 7.874 FX-102 Thru-beam type Parallel deviation 1,000 39.370 200 7.874 Setting distance L (mm in) Setting distance L (mm in) FX-102 300 11.811 0 Parallel deviation Parallel deviation 400 15.748 FT-42W Thru-beam type Setting distance L (mm in) Parallel deviation FT-42S Thru-beam type Setting distance L (mm in) Thru-beam type Right 60 2.362 Setting distance L (mm in) FT-31S New product introduction Others FX-102 150 5.906 FX-101 100 3.937 L Fiber head 50 1.969 0 60 2.362 White non-glossy paper 200mm 7.874in Up Down 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) FDA266 Amplifiers FX-500 series FX-100 series 60 2.362 INDEX 106 106 SENSING CHARACTERISTICS (TYPICAL) 60 2.362 Super Quality Square Head Type Cylindrical Type Narrow Beam Wide Beam Convergent Reflective Type Chemical / Oilresistant Vacuumresistant Semi-custom fibers FX-101 L Fiber head 50 1.969 Left Amplifiers FX-500 series FX-100 series Right 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) 150 5.906 FX-102 FX-101 100 3.937 L Fiber head 50 1.969 0 60 2.362 60 2.362 Up Down 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) 500 19.685 400 15.748 400 15.748 FX-102 FX-101 L Fiber head 50 1.969 Left Right 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) 60 2.362 Sensing field 150 5.906 100 3.937 FX-102 FX-101 50 1.969 0 30 1.181 White non-glossy paper 200mm 7.874in L Fiber head Left 20 10 0 10 20 0.787 0.394 0.394 0.787 Left Center Right Operating point (mm in) INDEX FDA275 Right 30 1.181 100 3.937 FX-101 Up Down 0 60 2.362 White non-glossy paper 200mm 7.874in L Fiber head 50 1.969 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FDA276 FX-101 200 7.874 L Fiber head 100 3.937 0 150 5.906 Left 60 2.362 150 5.906 L Fiber head 100 3.937 0 150 5.906 150 5.906 Up Down 100 50 0 50 100 3.937 1.969 1.969 3.937 Down Center Up Operating point (mm in) 150 5.906 * Vertical direction 250 9.843 White non-glossy paper 200mm 7.874in FX-102 L Fiber head 50 1.969 Left 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) FDA267 FX-101 White non-glossy paper 200mm 7.874in Reflective type FDA268 FX-101 60 2.362 200 7.874 FDA268 100 3.937 0 FX-102 300 11.811 Right 100 50 0 50 100 3.937 1.969 1.969 3.937 Left Center Right Operating point (mm in) FD-S32W 200 7.874 100 3.937 White non-glossy paper 200mm 7.874in 300 11.811 200 7.874 FX-102 * Vertical direction 500 19.685 200 7.874 150 5.906 Reflective type FDA270 Sensing field * Horizontal direction * Vertical direction White non-glossy paper 200mm 7.874in 80 3.150 Sensing field * Horizontal direction 250 9.843 FX-102 Right 40 0 40 1.575 1.575 Left Center Right Operating point (mm in) FD-62 250 9.843 150 5.906 Left 80 3.150 60 2.362 FDA265 L Fiber head 0 Reflective type FDA265 Reflective type FD-S33GW FDA276 Setting distance L (mm in) Others 250 9.843 Fiber Dimensions Reflective Type White non-glossy paper 200mm 7.874in White non-glossy paper 200mm 7.874in FX-101 100 3.937 30 1.181 200 7.874 White non-glossy paper 200mm 7.874in FX-102 200 7.874 Right * Vertical direction 100 3.937 60 2.362 Thru-beam Type Left 20 10 0 10 20 0.787 0.394 0.394 0.787 Left Center Right Operating point (mm in) Reflective type FDA274 150 5.906 0 Retroreflective Type 30 1.181 Sensing field * Horizontal direction Setting distance L (mm in) Fiber Options FX-101 50 1.969 White non-glossy paper 200mm 7.874in L Fiber head 300 11.811 250 9.843 FD-64X Liquid Leak / Liquid Detection FX-102 100 3.937 FDA271 FX-102 60 2.362 400 15.748 0 60 2.362 200 7.874 0 Retroreflective Type Heatresistant Right 250 9.843 Setting distance L (mm in) Small Spot Left 40 20 0 20 40 1.575 0.787 0.787 1.575 Left Center Right Operating point (mm in) Sensing field * Horizontal direction Sleeve Flat Type L Fiber head FD-61W Threaded Type 50 1.969 0 Fibers FX-101 100 3.937 Setting distance L (mm in) Earlier models comparison table 150 5.906 White non-glossy paper 200mm 7.874in Setting distance L (mm in) How to read Model No FX-102 Reflective type Sensing field 150 5.906 Setting distance L (mm in) 200 7.874 Choose by shape/ application Sensing field Setting distance L (mm in) Model Setting distance L (mm in) 250 9.843 FD-61G Reflective type Setting distance L (mm in) Sensing field Fiber Selection Guide FD-42GW Reflective type Right 60 2.362 Setting distance L (mm in) FD-42G Setting distance L (mm in) Tough Fiber Setting distance L (mm in) New product introduction White non-glossy paper 200mm 200 7.874 150 5.906 FX-102 7.874in L Fiber head Up Down FX-101 100 3.937 50 1.969 0 60 2.362 40 20 0 20 40 1.575 0.787 0.787 1.575 Down Center Up Operating point (mm in) FDA267 60 2.362 107 107 Refer to the "Operation Guide" on our website for details pertaining to operating instructions for the amplifier. PRECAUTIONS FOR PROPER USE *Never use this product as a sensing device for personnel protection. *In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Using in combination with the FX-300 / FX-410 series *The FX-100 series does not use the horizontal connectors that are used with the FX-300 / FX-410 series. Please note that horizontal connection cannot be performed using a connector attached cable. In addition, the optical communication function is not equipped on the FX-100 series, so it is unable to perform interference prevention for use with the FX-300 / FX-410 series. If using the FX-100 series together with the FX-300 / FX-410 series side-by-side, please set the same models together in groups. Mounting How to mount the amplifier Fit the rear part of the mounting section of the amplifier on a 35 mm 1.378 in width DIN rail. Press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the DIN rail. 1 *Make sure that the power supply is OFF while adding or removing the amplifiers. *Note that if a voltage exceeding the reted range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged. *Note that short-circuit of the load or wrong wiring may burn or damage the product. *Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction. *Verify that the supply voltage variation is within the rating. *If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. *In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. *Make sure to use the quick-connection cable (optional) for the connection of the controller. Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable. However, in order to reduce noise, make the wiring as short as possible. Operation indicator (Orange) ON key / Setting value UP key OFF key / Setting value DOWN key Digital display (Red) (Incident light intensity) Setting mode *Setting mode appears after the MODE key is pressed for 2 sec. in RUN mode. *Use M3 screws with washers for mounting. The tightening torque should be 0.5 N*m or less. Setting item Factory setting Teaching mode Timer operation setting Timer delays setting Emission amount setting Description Threshold value can be set in 2-point teaching, limit teaching, or full-auto teaching. Output operation setting M3 screw with washer Choose by shape/ application How to read Model No. Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Convergent Reflective Type Retroreflective Type MODE key 1 Note: Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. Model Chemical / Oilresistant Digital display (Green) (Threshold value) 2 Fiber Selection Guide Wide Beam 35 mm 1.378 in width DIN rail How to remove the amplifier Push the amplifier forward. Lift up the front part of the amplifier to remove it. Tough Fiber Wiring Part description 2 New product introduction [Dark-ON] [Without timer] Light-ON or Dark-ON can be set. Without timer, ON delay timer, or OFF delay timer can be set. When setting ON delay timer or OFF delay [ON-delay timer: 10 ms] timer in the timer operation setting mode, timer delays can be set. * When timer is not set, this mode is not [OFF-delay timer: 10 ms] displayed. * [Level 3] Emission frequency setting 1 (Response time: 2.5 ms or less) * Indicated as" Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others In case incident light intensity is saturated, emission amount can be reduced. Amplifiers FX-101 0 (Response time: 250 s or less) FX-102 Heatresistant FX-500 series When using the fiber heads in parallel, interference can be prevented by setting different emission frequency. However, when emission frequency 0 is set, interference cannot be prevented. Response time corresponds to emission frequency. FX-100 series "before production in November 2007. INDEX 108 108 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application PRECAUTIONS FOR PROPER USE PRO mode *PRO mode appears after the MODE key is pressed for 4 sec. in RUN mode. Setting item Factory setting Shift setting How to read Model No Earlier models comparison table External input setting Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Threshold value-storing setting mode (Note 2) Threshold value follow-up cycle setting (Note 3) GETA function setting (Note 4, 5) [OFF] [OFF] [OFF] Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions ECO setting Digital display inversion setting Threshold value margin setting Thru-beam Type Setting copy Retroreflective Type Reset Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX Description Shift amount can be selected from 0 to 80 % in the limit teaching. Select 0 % when it is desired [Shift amount 15 %] to set the present incident light intensity as a threshold value. External input can be selected from emission halt, limit teaching [+], limit teaching [-], full-auto teaching, ECO (Note 1), 2-point teaching or emission amount test. When setting the incident ", output turns ON / light intensity test " OFF every 100ms when the rate of incident [Emission halt] light intensity and threshold value is less than half of the set shift amount (for example, when the rate of incident light intensity and threshold value is within 10 % for 20 % of shift amount) at external input. [OFF] [OFF] [OFF] [NO] [NO] Threshold value set at the limit teaching, full-auto teaching or 2-point teaching by external input is stored. When selecting Auto in the emission amount setting mode, the set emission amount level is also stored. When incident light intensity exceeds threshold value, this mode can change the threshold value with each set cycle depending on variations of the incident light intensity. The follow-up shift amount is same as the one set in the shift setting mode. However, the threshold value is not stored. Variations can be reduced by correcting the present incident light intensity in each amplifier to a target value. Target value to offset incident light intensity can be selected from 0 to 2,000 by 100 unit each. For example, if the target value is set to 2,000 when the incident light intensity is 1,500, the incident light intensity becomes 2,000. It is possible to light up / turn off the digital display. When ECO setting mode is ON, the display turns off in 20 sec. approx. in RUN mode. To light up the display again, press any key for 2 sec. or more. Digital display can be inverted. Margin for threshold value to the present incident light intensity can be checked. When there is no margin, it is possible to make the digital display blink. : Set to "OFF": does not function. : Green blinks. : Red blinks. : Red and green blink. : When conducting limit teaching or 2-point teaching by external input, in case the rate of reference incident light intensity and threshold value after teaching is 200% or more, or in case it is less than half of the shift amount, output turns ON / OFF every 100 ms. (Note 6) The settings of the master side amplifier can be copied to the slave side amplifier. For details, refer to "Setting copy function". Returns to default settings (factory settings.) Notes: 1) When ECO is selected at the external input setting mode, key operation on the main body is invalid during external input. ", " ", 2) This mode is not indicated unless any of " " or " " is set at the external input setting mode. " (Incorporated from production in December 2007.) 3)If the incident light intensity becomes "300" or less, the follow-up operation stops. In that condition, threshold value [digital display (green)] blinks. This function can be used when thru-beam type or retroreflective type fiber is applied to this product. If reflective type fiber is applied, the function cannot be used depending on use conditions. 4)If MODE key is pressed in RUN mode when GETA function is used, the incident light intensity before setting GETA function is displayed on the red digital display for 2 sec. approx. 5)When GETA function is used in saturation of incident light intensity (4,000 or more,) " " is indicated on the red digital display. Correction value is up to 4,000. 6)This mode does not operate unless any of " ", " " or " " is set at the external input setting mode. (Incorporated from production in December 2007.) Refer to the "Operation Guide" on our website for details pertaining to operating instructions for the amplifier. Setting copy function *This can copy the settings of the master side amplifier to the slave side amplifier. *Be sure to use the setting copy function between the identical models (Between FX-101 models or FX-102 models). This function cannot be used between different models. *Only one sensor can be connected on slave side with a master side sensor for the setting copy function. *Threshold value, output operation setting, timer operation setting, timer setting, light-emitting amount setting, shift setting, external input setting, threshold value margin setting, ECO setting, digital display inversion setting, and threshold value margin setting can be copied. Set the setting copy mode of the master side amplifier to "Copy sending ON", and press the MODE key so that " " is shown on the digital display and the sensor is in copy ready state. For the setting method, refer to "Operation guide". Turn off the master side amplifier. Connect the master side amplifier with the slave side amplifier as shown below. Color code of cable with connector Master side amplifier (Brown) +V (Black) Input (White) External input + - 12 to 24V DC 10 % (Blue) 0 V Slave side amplifier (Brown) +V (Black) Input (White) External input (Blue) 0 V Turn on the master side amplifier and the slave side amplifier at the same time. (Note) " " is shown on the green digital display of the master side amplifier and 4-digit code is shown on the red digital display of it, then the copying starts. During copy communication, " " is shown on the green digital display of the slave side amplifier, and the ongoing copy communication indicator (" "" "" " "" "" "" "" ") is displayed on " the red digital display. When the copying is completed, " " is shown on the green digital display of the slave side amplifier, while the 4-digit code (the same code as the master side amplifier) is shown on the red digital display of it. Turn off the power of the master side amplifier and the slave side amplifier and disconnect the wire. *If copying the settings to another amplifier repeatedly, follow the steps to . Note: Take care that if the power is not turned on at the same time, the setting contents may not be copied. W hile the slave side amplifier is disconnected, turn on the power of the master side amplifier. Press the MODE key for 2 sec. approx. 109 109 Refer to the "Operation Guide" on our website for details pertaining to operating instructions for the amplifier. PRECAUTIONS FOR PROPER USE Others Code setting function *The code setting function makes it possible to set the output operation, timer operation, amount of light emitted, frequency of light emitted, ECO setting, external input, and amount of shift by selecting a code of one's choice. *While in the RUN Mode, pressing and holding both the ON key ( ) and OFF key ( ) simultaneously for 4 seconds will switch to the code setting function. 1st digit Output Timer operation (Note 1) 2nd digit 4th digit Emission External amount ECO input setting (Note 2) FX-101 FX-102 Shift (Note 1) 5% non 0 1 Emission halt ond 10 ms 1 2 Limit teaching [+] 2 3 Level 3 (OFF) D-ON 3rd digit Emission frequency ond 40 ms 3 ofd 10 ms OFF Limit teaching [-] Full-auto teaching 4 10 % 15 % 20 % No. Output operation Timer Emission amount setting (Note) D-ON non D-ON non Level 2 (ON) D-ON ofd 10 ms Level 3 (OFF) D-ON ofd 10 ms Level 2 (ON) D-ON ofd 40 ms Level 3 (OFF) D-ON ofd 40 ms Level 2 (ON) D-ON ond 10 ms Level 3 (OFF) D-ON ond 10 ms Level 2 (ON) D-ON ond 40 ms Level 3 (OFF) D-ON ond 40 ms Level 2 (ON) L-ON ond 40 ms Level 2 (ON) L-ON ond 40 ms Level 3 (OFF) L-ON ond 10 ms Level 2 (ON) L-ON ond 10 ms Level 3 (OFF) L-ON ofd 40 ms Level 2 (ON) L-ON ofd 40 ms Level 3 (OFF) L-ON ofd 10 ms Level 2 (ON) L-ON ofd 10 ms Level 3 (OFF) L-ON non Level 2 (ON) L-ON non Level 3 (OFF) Difference between previous model and upgraded one *For upgraded ones (production in and after December 2007), "P" is marked near the beam-emitting inlet. Previous ones have no marking. Appearance and functions have been changed. "P" indication Beam-emitting inlet ofd 40 ms 0 1 ECO 25 % non 1 2 Emission halt 30 % ond 10 ms 2 3 Limit teaching [+] 35 % ond 40 ms 3 4 Limit teaching [-] 40 % ofd 10 ms 0 1 Full-auto teaching 45 % ofd 40 ms 1 2 ECO 50 % 2 3 2-point teaching Level 3 (OFF) Note: Until production in November 2007, OFF or ON was selectable. The emission amount of Level 2 (ON) is about 40% of that of Level 3 (OFF). Fiber Selection Guide Model Choose by shape/ application Earlier models comparison table Quick setting function *The quick setting function makes it possible to set the content of the SET Mode (output operation, timer operation, amount of light emitted, and frequency of light emitted) simply by selecting a setting number. *While in the RUN Mode, pressing and holding both the ON key ( ) and OFF key ( ) simultaneously for 2 seconds will switch to the quick setting function. Tough Fiber How to read Model No. Code *Our products have been developed / produced for industrial use only. *Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. *Take care that the product is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance. *This product is suitable for indoor use only. *Avoid dust, dirt, and steam. *Take care that the product does not come in contact with oil, grease, organic solvents, such as thinner, etc., strong acid or alkaline. *This product cannot be used in an environment containing inflammable or explosive gases. *Never disassemble or modify this product. *EEPROM is adopted to this product. It is not possible to conduct teaching 100 thousand times or more, because of the EEPROM's lifetime. New product introduction Level 2 (ON) L-ON ON Level 1 OFF 3 0 4 Incident light intensity test 1 2-point teaching ON 1 2 Incident light intensity test Auto 2 3 3 4 Notes:1)When the present setting is out of the code setting range, " " is shown. When " " is selected, the set content of the digit is not changed. 2)Until production in November 2007, OFF or ON was selectable. The emission amount of Level 2 is about 40% of that of Level 3. The emission amount of Level 1 is about 20% of that of Level 3. 3)The factory setting is " ". Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 110 110 New product introduction Tough Fiber FX-101 FX-102 Fiber Selection Guide 0.8 0.031 Model Choose by shape/ application How to read Model No Refer to p.48~ for details of fiber dimensions. The CAD data in the dimensions can be downloaded from our website. DIMENSIONS (Unit: mm in) Amplifier 48 1.890 30 1.181 20 13.2 0.787 0.520 6 0.236 FX-101(P)-ZFX-102(P)-Z Amplifier 10.85 6 0.236 2.7 0.106 0.7 0.028 0.8 0.031 OFF key / Setting value DOWN key ON key / Setting value UP key MODE key 4.1 Operation indicator (Orange) 0.161 Digital display (Green, Red) 48 1.890 30 1.181 20 13.2 0.787 0.520 6 0.236 6 0.236 0.427 2.7 0.106 0.7 0.028 OFF key / Setting value DOWN key ON key / Setting value UP key MODE key 4.1 Operation indicator (Orange) 0.161 Digital display (Green, Red) Earlier models comparison table 0.75 0.030 Fibers Super Quality Threaded Type 66.2 2.606 9 0.354 7 0.276 Cylindrical Type 0.394 10 6.5 0.256 Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type 3 0.118 50 1.969 35 1.378 65.5 2.579 14.5 0.571 3.2 2 0.126 6.5 0.256 0.079 o3.2 o0.126 3.2 0.126 Chemical / Oilresistant Heatresistant Vacuumresistant 9.25 0.364 o6.2 mm o0.244 in spot facing, 3 0.118 deep Liquid Leak / Liquid Detection Semi-custom fibers 6.2 mm 0.244 in spot facing, 3 0.118 deep 3.2 0.126 o3.2 o0.126 0.8 0.031 Material: PBT 50 1.969 35 1.378 65.5 2.579 0.7 0.028 OFF key / Setting value DOWN key ON key / Setting value UP key MODE key 1 0.039 5.5 0.217 End plate (Optional) Suitable for 35 mm 1.378 in width DIN rail 9 0.354 9 0.354 0.8 0.031 10 30 0.394 1.181 8.1 0.319 1.1 0.043 7 0.276 4 0.157 10 0.394 MS-DIN-E 3.2 8.1 0.126 0.319 2 0.079 6 6 47 1.850 0.236 0.236 29 1.142 2.7 12.2 20 0.787 0.106 0.480 4.1 Operation indicator (Orange) 0.161 Digital display (Green, Red) 1 0.039 24.5 0.965 35 1.378 5 0.197 14.5 0.571 Previous dimensions (production before November 2007) 11.5 0.453 4 0.157 Fiber Options 1 0.039 15 0.591 o3.2 o0.126 Note: The protection cover has been attached from the production at July, 2011. 7.2 mm 0.283 in spot facing, 4 0.157 deep Retroreflective Type 10 30 0.3941.181 3 0.118 Suitable for 35 mm 1.378 in width DIN rail Amplifier mounting bracket (Optional) o7.2 mm o0.283 in spot facing, 4 0.157 deep 4 0.157 10 o6.5 o0.256 0.8 0.031 0.394 Note: The protection cover has been attached from the production at July, 2011. MS-DIN-4 7 0.276 8.1 0.319 o3.2 o0.126 1 0.039 6 0.236 1.1 0.043 2 0.079 10 30 0.394 1.181 0.8 0.031 4 0.157 66.2 2.606 9 0.354 2 0.079 6 0.236 1.1 0.043 Square Head Type 0.75 0.030 o3.2 o0.126 13.5 0.531 3.2 2 0.126 0.079 3 0.118 50 1.969 35 1.378 64.5 2.539 Suitable for 35 mm 1.378 in width DIN rail CN-14A-C CN-14A-R-C Connector attached cable (Optional) CN-14A-C2 is attached FX-101(P)-CC2 / FX-102(P)-CC2 Fiber Dimensions Thru-beam Type Retroreflective Type 2.75 0.108 3 0.118 15 0.591 M3 (Iength 18 mm 0.709 in) pan head screws 60 2.362 Amplifiers FX-500 series FX-100 series INDEX M3 square nut 5.6 0.220 24.7 0.972 Reflective Type Others 3 0.118 1.6 0.063 Material: Polycarbonate 32 1.260 4 0.157 Suitable for 35 mm 1.378 in width DIN rail 8 0.315 ( ) L 35 (1.378 ) 50 (1.969 ) (0.3158 ) o3.7 o0.146 cable * Length L Model No. CN-14A(-R)-C1 CN-14A(-R)-C2 CN-14A(-R)-C3 CN-14A(-R)-C5 Length L 1,000 39.370 2,000 78.740 3,000 118.110 5,000 196.850 111 112 112 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam INDEX C CN-14A CN-14A-C1 FX-100 Connector CN-14A-C2 FX-100 CN-14A-C3 CN-14A-C5 CN-14A-R-C1 CN-14A-R-C2 CN-14A-R-C3 CN-14A-R-C5 CN-71-C1 CN-71-C2 CN-71-C5 CN-72-C1 CN-72-C2 CN-72-C5 CN-73-C1 CN-73-C2 CN-73-C5 CN-74-C1 CN-74-C2 CN-74-C5 Connector Attached Cable FX-100 Connector p.102 p.102/p.110 p.102/p.103/ p.110 p.102/p.110 Attached Cable (Flexible) FX-500 Quick-connection Cable p.74/p.96 F Fiber Bender Retroreflective Type FC-FX-1 FX-100 Protection Cover Chemical / Oilresistant FD-30 Super Quality Fiber p.11/p.39/p.56/ p.85 Heatresistant FD-31 FD-31W Threaded Type Fiber p.13/p.39/p.56/ p.85 FD-32G FD-32GX Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers Threaded / Small Spot Type Fiber p.102/p.103 p.13/p.23/p.39/ p.56/p.85/p.105 p.13/p.32/p.39/ p.56/p.86/p.105 Super Quality Fiber p.11/p.39/p.56/ p.86 FD-41 Threaded Type Fiber p.13/p.39/p.56/ p.86 Sleeve Fiber FD-41SW p.19/p.39/p.56/ p.86/p.105 p.19/p.39/p.56/ p.86 FD-41W Threaded Type Fiber p.13/p.39/p.56/ p.86/p.105 FD-42G FD-42GW Threaded / Small Spot Type Fiber p.13/p.23/p.39/ p.57/p.86/p.106 FD-60 FD-61 Super Quality Fiber Threaded Type Fiber FD-61G FX-500 series FD-61S FX-100 series FD-61W FD-62 Sleeve Fiber Threaded Type Fiber FD-64X INDEX p.18/p.45/p.66 FD-40 FD-41S FD-A16 FD-AL11 p.17/p.19/p.39/ p.58/p.88 FD-EG30 Threaded / Small Spot Type Fiber p.13/p.23/p.39/ p.58/p.88 FD-EG30S Sleeve Fiber p.19/p.39/p.59/ p.88 FD-EG31 Threaded / Small Spot Type Fiber p.13/p.23/p.39/ p.59/p.88 Liquid Leak / Liquid Detection Fiber p.35/p.39/p.59 FD-F4 FD-F41 FD-F41Y FD-F71 FD-F8Y FD-FA93 FD-H13-FM2 FD-H18-L31 FD-H20-21 FD-H20-M1 FD-H25-L43 Wide Beam Fiber Heat-resistant Fiber p.31/p.40/p.60/ p.88 FD-H25-L45 p.31/p.40/p.60/ p.89 FD-H30-KZ1V Vacuum-resistant Fiber FD-H30-KZ1V-S p.33/p.44 p.32/p.40/p.61 FD-H30-L32 p.31/p.40/p.61/ p.89 FD-H30-L32V-S FB-1 Liquid Leak / Liquid Detection Cylindrical / Sleeve Fiber FD-H30-L32V Convergent Reflective Type Vacuumresistant FD-E13 FD-E23 FD-H35-20S FD-H35-M2 FD-H35-M2S6 FD-HF40Y FD-L10 FD-L11 FD-L12W FD-L20H FD-L21 FD-L21W FD-L22A FD-L23 FD-L30A FD-L31A Heat-resistant Fiber p.33/p.44 Vacuum-resistant Fiber Heat-resistant Fiber p.31/p.40/p.61/ p.89 Liquid Leak / Liquid Detection Fiber p.35/p.40/p.61 p.26/p.40/p.62/ p.89 Convergent Reflective Type Fiber p.26/p.40/p.62/ p.90 p.26/p.40/p.62/ p.90 p.26/p.40/p.63/ p.90 FD-L32H FD-R31G FD-R32EG FD-R33EG FD-R34EG FD-R41 p.32/p.40/p.61/ p.89 Square Head / Small Spot Type Fiber p.15/p.23/p.40/ p.63 Square Head type Fiber p.15/p.40/p.63 FD-R60 Threaded Type Fiber p.11/p.39/p.57/ p.86 p.13/p.40/p.63/ p.90 FD-R61Y p.13/p.39/p.57/ p.87 Square Head / Chemical / Oil-resistant Fiber p.15/p.29/p.40/ p.91 FD-S21 Cylindrical Fiber p.13/p.39/p.57/ p.87/p.106 p.17/p.40/p.63/ p.91 FD-S30 Super Quality Fiber p.11/p.40/p.64/ p.91 p.19/p.39/p.57/ p.87 p.13/p.39/p.57/ p.87/p.106 p.13/p.39/p.58/ p.87/p.106 p.25/p.39/p.58/ p.87 FD-S31 FD-S32 FD-S32W FD-S33GW Cylindrical Fiber FD-S60Y Chemical / Oil-resistant Fiber p.17/p.40/p.64/ p.91 p.17/p.41/p.64/ p.91/p.106 p.29/p.41/p.64/ p.91 113 113 INDEX FD-V30 FD-V30W New product introduction Sleeve Fiber p.19/p.41/p.64/ p.92 FD-V50 p.19/p.41/p.65/ p.92 FD-Z20HBW p.21/p.41/p.65/ p.92 FD-Z20W FD-Z40HBW FD-Z40W Flat Type Fiber FD-Z50HW Narrow Beam Fiber FDP-1000 FDP-1500 FDP-500 FDP-N1000 FDP-N1500 FDP-N500 FR-KZ22E FR-KZ50E FR-KZ50H Protective Tube (For Reflective Type Fiber) p.21/p.41/p.65/ p.92 p.24/p.41/p.65/ p.92 p.45/p.67 p.24/p.27/p.38/ p.55/p.84 Narrow Beam / Retroreflective Type Fiber p.24/p.27/p.38/ p.55/p.85 FR-Z50HW p.24/p.27/p.38/ p.55/p.85 FT-140 Threaded Type Fiber p.12/p.36/p.48/ p.79 FT-30 Super Quality Fiber p.11/p.36/p.48/ p.79 FT-31 Threaded Type Fiber p.12/p.36/p.48/ p.79 FT-31S Sleeve Fiber p.19/p.36/p.48/ p.79/p.105 FT-31W Threaded Type Fiber p.12/p.36/p.48/ p.79/p.105 Super Quality Fiber p.11/p.36/p.48/ p.79 FT-42 Threaded Type Fiber p.12/p.31/p.36/ p.48/p.79 FT-42S Sleeve Fiber p.19/p.36/p.48/ p.79/p.105 FT-40 FT-42W FT-43 Threaded Type Fiber p.12/p.36/p.48/ p.79/p.105 FT-45X p.12/p.36/p.49/ p.79/p.105 FT-A11 p.25/p.36/p.49/ p.79/p.105 FT-A11W p.25/p.36/p.49/ p.79 FT-A32 FT-A32W FT-AL05 FT-E13 FT-E23 FT-F93 Wide Beam Fiber Cylindrical / Sleeve Fiber Liquid Leak / Liquid Detection Fiber FT-H20-J20 p.30/p.36/p.50/ p.80 FT-H20-J30 p.31/p.44 FT-H20-J30-S FT-H20-J50 FT-H20-J50-S FT-H20-M1 FT-H20-VJ50 Heat-resistant Fiber FT-H30-M1V-S p.31/p.44 How to read Model No. p.31/p.44 p.30/p.36/p.50/ p.80 p.33/p.44 Vacuum-resistant Fiber p.32/p.36/p.50/ p.80 p.30/p.36/p.50/ p.81 FT-HL80Y Chemical / Oil-resistant Fiber p.29/p.36/p.50/ p.81 FT-J8 Fiber for Atmospheric Side p.33/p.44/p.66 FT-KS40 FT-KV26 FT-KV40 FT-KV40W Narrow Beam Fiber p.24/p.36/p.51/ p.81 FT-L80Y Chemical / Oil-resistant Fiber p.29/p.36/p.51/ p.81 FT-R31 Square Head Type Fiber p.15/p.36/p.51 Threaded Type Fiber p.12/p.36/p.51/ p.81 Square Head Type Fiber p.14/p.15/p.36/ p.51/p.81 Square Head / Chemical / Oil-resistant Fiber p.15/p.29/p.37/ p.52/p.82 FT-S11 Cylindrical Fiber p.16/p.37/p.52/ p.82 FT-S20 Super Quality Fiber p.11/p.37/p.52/ p.82 FT-S21 p.16/p.19/p.36/ p.49/p.80 FT-S31W Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Cylindrical Fiber Super Quality Fiber Cylindrical Fiber p.16/p.37/p.52/ p.82/p.105 p.11/p.37/p.52/ p.82 p.16/p.37/p.52/ p.82/p.105 p.16/p.37/p.52/ p.82 FT-V23 p.19/p.37/p.52/ p.82 Sleeve Fiber FT-V25 FT-V30 Fiber Options Semi-custom fibers p.16/p.37/p.52/ p.82 FT-S32 FT-V24W Fibers p.15/p.37/p.51 FT-S21W FT-S30 Earlier models comparison table p.31/p.44 p.30/p.36/p.50/ p.80 Heat-resistant Fiber FT-R41W FT-R42W FT-R43 FT-R44Y FT-R60Y Model Choose by shape/ application FT-H35-M2 FT-H35-M2S6 FT-R40 Fiber Selection Guide p.30/p.36/p.50/ p.80 p.30/p.36/p.50/ p.80 FT-H20-VJ50-S FT-H20-VJ80 FT-H20-VJ80-S FT-H20W-M1 FT-H30-M1V Tough Fiber p.31/p.44 FT-H20-J20-S p.25/p.36/p.49/ p.80 p.35/p.36/p.49 p.30/p.36/p.50/ p.80 FT-H13-FM2 p.19/p.37/p.53/ p.82 p.19/p.37/p.53/ p.83 FT-V40 Cylindrical Fiber p.16/p.37/p.53/ p.83 FT-V80Y Chemical / Oil-resistant Fiber p.29/p.37/p.53/ p.83 Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX 114 114 New product introduction Tough Fiber Fiber Selection Guide Model Choose by shape/ application How to read Model No Earlier models comparison table Fibers Super Quality Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type Small Spot Narrow Beam Wide Beam Convergent Reflective Type Retroreflective Type Chemical / Oilresistant Heatresistant Vacuumresistant Liquid Leak / Liquid Detection Fiber Options Semi-custom fibers Fiber Dimensions Thru-beam Type Retroreflective Type Reflective Type Others Amplifiers FX-500 series FX-100 series INDEX INDEX FT-Z20HBW FT-Z20W FT-Z30 FT-Z30E FT-Z30EW FT-Z30H FT-Z30HW FT-Z30W FT-Z40HBW FT-Z40W Flat Type Fiber FT-Z802Y Chemical / Oil-resistant Fiber FTP-500 FTP-1000 FTP-1500 FTP-N500 FTP-N1000 FTP-N1500 Protective Tube (For Thru-beam Type Fiber) FV-BR1 Photo-terminal for Vacuum-resistant Fiber p.33/p.44/p.66 Vacuum-resistant Expansion Lens Vacuum-resistant Side-view Lens p.33/p.42/p.66 FV-LE1 FV-SV2 FX-101 FX-101-CC2 FX-101P FX-101P-CC2 FX-102 FX-102-CC2 FX-102P FX-102P-CC2 FX-501 FX-501P FX-502 FX-502P FX-505-C2 FX-505P-C2 FX-AT15A FX-AT2 FX-AT3 FX-AT4 FX-AT5 FX-AT6 FX-CT2 FX-CT3 FX-LE1 FX-LE2 FX-MB1 FX-MR1 FX-MR2 FX-MR3 FX-MR5 FX-MR6 FX-MR7 FX-MR8 FX-MR9 FX-SV1 M MS-AJ1-F MS-AJ2-F MS-DIN-2 MS-DIN-4 p.20/p.37/p.53/ p.83 MS-DIN-E End Plate MS-EX3 FX-MR2 Mounting Bracket MS-FD-2 p.20/p.37/p.54/ p.84 p.29/p.37/p.54/ p.84 p.45/p.66 MS-FD-3 MS-FD-F7-1 MS-FD-F7-2 MS-FX-01Y MS-FX-02Y MS-FX-03Y MS-FX-YF R RF-003 Digital Fiber Sensor FX-100 series Digital Fiber Sensor FX-500 series p.102/p.103/ p.104/p.110 p.74/p.76/p.77/ p.96 p.74/p.76/p.78/ p.96 Fiber Single-core Holder Fiber Attachment Fiber Cutter p.45 p.44/p.67 p.44 Lens for Thru-beam Type Fiber p.42/p.67 FX-500 Fiber Amplifier Protection Seal p.75/p.76 p.23/p.43/p.67 Lens for Reflective Type Fiber Square Head Type M3, Reflective Type Fiber & Spot Lens Side-view Lens for Thru-beam Type Fiber Universal Sensor Mounting Stand FX-500 Amplifer Mounting Bracket FX-100 Amplifer Mounting Bracket p.23/p.43/p.68 p.42/p.69 p.45 p.75/p.96 p.102/p.110 RF-13 RF-210 RF-220 RF-230 Fiber Mounting Bracket p.74/p.96/ p.102/p.110 p.69 p.33/p.44/p.69 p.69 FD-F71 SUS Mounting Bracket FD-F71 PVC Mounting Bracket Liquid Inflow Prevention Joint Protective Tube Extension Joint Fiber Mounting Joint Joint Internal Ferrulre FR-KZ50E/KZ50H Exclusive Reflector p.35 p.35/p.45 p.44/p.69 Reflective Tape Reflector p.45/p.69 115 116 Communication Unit for Open Network The digital sensor can be connected directly to the 3 types of open network! Other types of analog input sensors can also be connected! Fiber Sensor Guide Book Scattered digital sensors can be centrally managed and set through an open network. Applicable Digital Sensor Digital Fiber Sensor GA-311 DPS-400 DPH-100 Digital Laser Sensor Digital Pressure Sensor GH series LS series FX-500 Please contact .......... Panasonic Industrial Devices SUNX Co., Ltd. All Rights Reserved No. CE-FIBERGUIDE-1-7 June, 2014 Specifications are subject to change without notice. Panasonic Industrial Devices SUNX Co., Ltd. 2014 Printed in Japan