Product Specification
PE45450
Page 3 of 12
Document No. DOC-44314-5 │w ww.psemi.com ©2013-2014 Peregrine Semiconductor Corp. All rights reserved.
Table 2. Pin Descriptions
Figure 3. Pin Configuration (Top View)*
Pin No. Pin Name Description
1, 3, 4, 6,
7, 9 GND Ground
2 RF1* RF port 1
5 VCTRL Control voltage
8 RF2* RF port 2
Pad GND Exposed pad: Ground for proper operation
10–12 N/C No connect
Moisture Sensitivity Level
The Moisture Sensitivity Level rating for the
PE45450 in the 12-lead 3x3 mm QFN package is
MSL1.
Table 3. Operating Ranges
Parameter Symbol Min Typ Max Unit
Control voltage
Power limiting mode
Power reflecting mode VCTRL
–2.5
–2.5
–0.5
+2.5
V
V
RF input power, CW1 PMAX,CW 40 dBm
RF input power, pulsed2 PMAX,PULSED 47 dBm
Operating temperature
range TOP –55 +25 +85 °C
Operating junction
temperature1 TJ +290 °C
RF input power, unbiased2,3 P
MAX,UNB 47 dBm
Table 4. Absolute Maximum Ratings
Exceeding absolute maximum ratings may cause
permanent damage. Operation should be
restricted to the limits in the Operating Ranges
table. Operation between operating range
maximum and absolute maximum for extended
periods may reduce reliability.
Notes: 1. Human Body Model (HBM, MIL_STD 883 Method 3015.7)
2. Machine Model (JEDEC JESD22-A115)
3. Charged Device Model (JEDEC JESD22-C101)
Parameter Symbol Min Max Unit
Control voltage
Power limiting mode
Power reflecting mode VCTRL –3.3 3.6 V
Storage temperature range TST –65 +150 °C
ESD voltage HBM1, all pins VESD,HBM 8000 V
ESD voltage MM2, all pins VESD,MM 600 V
ESD voltage CDM3, all pins VESD,CDM 1000 V
Notes: 1. CW, 100% duty cycle, in 10 min, 50Ω
2. Pulsed, 0.1% duty cycle of 1 µs pulse width in 10 min, 50Ω
3. VCTRL = 0V or VCTRL pin left not connected
Note: * Pins 10–12 can be ground if deemed necessary by the customer.
Note: * RF pins 2 and 8 must be at 0 VDC. The RF pi ns do not require DC
blocking capacitors for proper operation if the 0 VDC requirement is met.
Latch-Up Avoidance
Unlike conventional CMOS devices, UltraCMOS
devices are immune to latch-up. Electrostatic Discharge (ESD) Precautions
When handling this UltraCMOS device, observe
the same precautions that you would use with
other ESD-sensitive devices. Although this device
contains circuitry to protect it from damage due to
ESD, precautions should be taken to avoid
exceeding the rating specified.