INPUT SPECIFICATIONS:
Voltage …...………........….................................................... 90~264Vac
Frequency ………………………………………….……………..... 50 to 60Hz
Inrush Current ………………............. Cold Start @25℃
80A max. @240Vac
Conducted EMI ………………………….………………CISPR/FCC Class B
Leakage Current …………………………………………….…… 3.5mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit Protection ………………………….……………… Continuous
Over Voltage Protection ……………...........................................….....… Yes
Temperature Coefficient ……………………............................… ±0.05%/℃
GENERAL SPECIFICATIONS:
NOTE:
Isolation ………………………………………… Input to output = 4,242VDC
1. Voltage accuracy at 60% full load.
Operating Temperature .............................. 0 ~ 60℃ (see derating curve)
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Storage Temperature ……………………………...….......……........ -20~85℃
Ripple & Noise measurement @20MHz BW.
Humidity …………………..….......……........ 93% RH max. Non condensing
3. Line regulation measured from 100Vac to 240Vac, full load.
Cooling …………………………………..……………….. Natural Convection
4. Load regulation measured from 60% to 100% full load and from 60% to
Switching Frequency …………………………………………… 60KHz Typical
20% full load (60% +/- 40% full load).
MTBF ……… MIL-HDBK-217F, GB, at 25℃/115VAC ………. 200K hrs min.
5. Typical efficiency at 230VAC and full load at 25℃.
Altitude …………………………………………………………………… 2000m
6. ”Various TR Series adapters are PSE certified. PSE certification
Dimensions ……..…. 5.197x2.283x1.201 inches (132.00x58.00x30.50 mm)
alone is not sufficient for importation into Japan. A valid PSE mark
Weight ……………………………………………………… 345g(0.76 Pounds)
must contain the name of the importer as shown in the example below.
AC Inlet ……………….…………………………………...……… IEC320/C14
If PSE mark is required, the name of the registered importer must be
SAFETY AND EMC:
supplied to Cincon on order placement. Product labels will not contain
Emission and lmmunity ………… EN55022 Class B, FCC Part 15 Class B
PSE mark if importer name is not supplied. Consult factory or local
EN61000-6-3,EN61000-3-2,EN61000-3-3
represen tative for details”
EN55024, EN61204-3, EN61000-6-1
Safety ………………………………… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
DC Plug type: V+ ─●)─ V-
DC Plug :Right Angle(ψ5.5/ψ2.1) L12mm
18AWG/1800mm
IEC320/C14
LED
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
0%
25%
50%
75%
100%
0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)