Commercial Thermostats DESCRIPTION Thermostats can provide either temperature control or overtemperature protection by breaking electrical contact when a specified temperature is reached. Honeywell manufactures a wide range of 12,7 mm [0.5 in] commercial snap-action thermostats for possible use in a wide array of small and major appliances, office copy machines, medical equipment, heat detectors, HVAC equipment and more. These snap-action thermostats include automatic and manual reset options, phenolic or ceramic housings and a wide variety of mounting brackets and terminal options. Each thermostat's design is configured from a base unit, and may be customized for temperature tolerance and mechanical configurations, meeting the customer's needs for accuracy and exactitude. Honeywell can also integrate these thermostats in higher value cable assemblies, incorporating wire harness and connectors. TABLE OF CONTENTS DESCRIPTION NOMENCLATURE DEFINITION OF TERMS NOTES COMMERCIAL THERMOSTATS 2450R/2450HR/2455R/2452R/2452HR Series Phenolic Automatic Reset 2450RC/2450RCH/2455RC Series Ceramic Automatic Reset 2455RM/2450CM Series Phenolic or Ceramic Manual Reset 2455RD Series Phenolic Manual Reset 2455RBV Series Overmolded Automatic Reset 2450A/2455RA Series Heat Detection 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" REDI-TEMP THERMOSTATS 3455RC Series MOUNTING HARDWARE Brackets Brass mounting studs Terminals p. 1 p. 2 p. 3 p. 3 p. 4 p. 6 p. 9 p. 11 p. 13 p. 15 p. 17 p. 19 p. 20 p. 21 p. 22 Commercial Thermostats NOMENCLATURE The nomenclature given in Figure 1 is provided for reference only. Figure 1. Commercial Thermostat Nomenclature 2 www.honeywell.com/sensing DEFINITION OF TERMS * Automatic Reset: A type of thermostat that will automatically reset at a specific temperature (i.e. a thermostat operates at o o o o 65,5 C [150 F] and resets at 48,89 C [120 F]). * Bimetal: Two dissimilar metals bonded together to form the material for manufacturing thermally-sensitive discs which actuate the thermostat. * Close on Rise (COR): Refers to operation of the contacts. When the temperature rises to its set point, the contacts close or make contact and complete the circuit. * Contact Resistance: The value of resistance measured between the terminals. * Dielectric Strength: The value of insulation between two electrically conducting parts. It may be tested by the application of a predetermined overvoltage for a specified time. * Differential: The temperature difference between the operate and reset set points, also known as operate and reset. - Nominal: The temperature difference between nominal set points regardless of tolerance. - Maximum: Maximum number of degrees between actual opening and closing set points. - Minimum: Minimum number of degrees between actual opening and closing set points. * Exposure Temperature: Thermal environment of a device during application operation. * FLA (Full Load Amps): Current taken from the line by the motor when the motor is yielding the rated hp at the rated voltage and frequency. * Life Cycles: The endurance rating of the thermostat expressed in number of operations with stated electrical load applied. Temperature limit application = open on rise. * LRA (Locked Rotor Amps): The amount of current the motor can be expected to draw under starting conditions when full voltage is applied, also known as starting inrush current. * Manual Reset: A bimetal thermostat with a reset button that must be pressed to reset the contacts. * Open on Rise (OOR): Refers to the operation of contacts. When the temperature rises to its set point the contacts open, terminating the circuit. * Overmold: Encapsulation with an insulating material. * Phenolic: Thermoset plastic used for the insulating body of the thermostat. * Set Point: The nominal temperature at which the thermostat operates. * SPST (Single Pole/Single Throw): A switch with one current path which can be either open or closed. * Tolerance: The allowable range above and below the set point temperature. * Operate: Change of state when the thermostat reaches its set point. * Reset: Change of state when the thermostat returns to its original condition prior to operation. NOTES * Standard Temperature Characteristics Tables: - Temperatures: Please consult applications engineering for temperature ranges, tolerances and differentials not noted. The operating temperature ranges include tolerances. - Tolerances: The tolerances given have been established after review of many thermostat applications. Attempts should be made to establish the widest acceptable tolerance possible. * UL and CSA Approvals: 12,7 mm [0.5 in] thermostats are available with multiple agency approval for incorporation into equipment. * Fan control applications: Require thermostat set points to be derated by 20 C from the equivalent temperature limit application. They also close on rise. * Dimensions: Are for reference only and are given in mm [in]. Honeywell Sensing and Control 3 Commercial Thermostats Figure 2. 2450R/2450HR/2455R/2452R/2452HR Series Phenolic Automatic Reset Thermostat The 2450R/2450HR/2455R/2452R/2452HR Series is a single pole, single throw, snap-acting, non-adjustable thermostat which may be used in applications such as power supplies, general appliances and medical equipment. A temperature-sensitive bimetal disc, electrically and thermally isolated from the switch, is used to actuate the normally-closed contacts. Contacts open when surface or ambient temperatures increase to the operating set point of the calibrated bimetal disc. The entire switch is enclosed in a phenolic housing; the bimetal disc is retained by a metal heat-conducting end cap. Due to the small size of this unit and the inherently low mass of the bimetal snap-action disc, response of this thermostat to temperature changes is extremely rapid, compared to other commercially available thermostatic devices. A variety of mounting brackets and terminals are available. All versions are UL/CSA approved. The 2452R/2452HR/2455R version meets the requirements of EN60730-01. Potential applications include: * Power supplies * Appliances * Medical equipment * Water heaters * Office automation * Industrial equipment * HVAC equipment Table 1. 2450R/2450HR/2455R/2452R/2452HR Series Standard Temperature Characteristics Standard Mean Differential Tolerance Operating Temperature Range C [F] Open Close C [F] C [F] 4 0 C to 26 C [32 F to 79 F] 4 [7] 4 [6] 4 [6] 4 [6] 3 [5] 6 [10] 6 [10] 5 [9] 5 [8] 5 [8] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 14 to 16 [25 to 29] 8 to 14 [15 to 24] 27 C to 82 C [80 F to 180 F] 5 [9] 4 [7] 4 [6] 3 [5] 3 [5] 3 [5] 8 [15] 6 [11] 6 [10] 6 [10] 5 [9] 5 [8] 45 to 56 [81 to 100] 34 to 45 [61 to 80] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 8 to 16 [15 to 29] 83 C to 110 C [181 F to 230 F] 6 [10] 5 [8] 4 [7] 4 [6] 4 [6] 4 [6] 8 [15] 8 [15] 7 [12] 6 [10] 5 [9] 5 [8] 45 to 56 [81 to 100] 34 to 45 [61 to 80] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 8 to 16 [15 to 29] 111 C to 150 C [231 F to 302 F] 7 [12] 5 [9] 5 [8] 4 [7] 4 [7] 4 [7] 10 [18] 8 [15] 7 [12] 7 [12] 6 [11] 6 [10] 45 to 56 [80 to 100] 34 to 45 [61 to 80] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 14 to 16 [25 to 29] www.honeywell.com/sensing Table 2. 2450R/2450HR/2455R/2452R/2452HR Series Specifications Characteristic Parameter Switch type SPST Reset type automatic Amperage See Tables 3, 4 Voltage 120 Vac to 250 Vac Operating temperature range 0 C to 150 C [32 F to 302 F] Environmental exposure range -18 C to 177 C [0 F to 350 F] Materials: phenolic Base silver alloy Contacts unplated brass, plated brass or steel Terminals aluminum, brass or stainless steel Closure Brackets aluminum or stainless steel UL and CSA approvals * 2455R: 6,35 mm [0.25 in] clearance; UL File MH8267, UL File E36103; CSA File LR21048 * 2450HR: 1,59 mm [0.0625 in] clearance; UL File E36103; CSA File LR21048 * 2450R: 1,59 mm [0.0625 in] clearance; UL File E36103; CSA File LR 21048 * 2452R: 2.66mm [0.105 in] clearance; UL E36103 * 2452HR: 2.66mm [0.105 in] clearance; UL36103 Weight 6 g [0.2 oz] (does not include brackets or wire leads) Table 3. 2450R/2450HR/2452R/2452HR Contact Ratings Life Cycles 120 Vac 100,000 15 A resistive 30,000 125 VA pilot duty Note: 2450 approval rating is limited by EN60730-1 to 125 Vac max. 240 Vac 10 A resistive 125 VA pilot duty 277 Vac 10 A resistive - Table 4. 2455R Contact Ratings Life Cycles 100,000 120 Vac 240 Vac 15 A resistive 10 A resistive 4.4 FLA 26.4 LRA 2.2 FLA 13.2 LRA 125 VA pilot duty 125 VA pilot duty 6,000 5.8 FLA, 34.8 LRA 2.9 FLA, 17.4 LRA Note: Additional contact ratings are available, please contact Honeywell. Figure 3. 2450R/2450HR/2455R/2452R/2452HR Basic Dimensions 2450R 2450HR 2452R 277 Vac 7.2 A resistive - 2455R 2452HR Honeywell Sensing and Control 5 Commercial Thermostats Figure 4. 2450RC/2450RCH/2455RC Series Automatic Reset Thermostat The 2450RC/2450RCH/2455RC Series is a single pole, single throw, snap-acting, non-adjustable thermostat which may be used in applications such as industrial and electrical equipment. A temperature-sensitive bimetal disc, electrically and thermally isolated from the switch, is used to actuate the normally-closed contacts. Contacts open when surface or ambient temperatures increase to the operating set point of the calibrated metal disc. The entire switch is enclosed in a ceramic housing; the bimetal disc is retained by a metal heat-conducting end cap. Due to the small size of this unit and the inherently low mass of the bimetal snap-action disc, response of this thermostat to temperature changes is extremely rapid, compared to other commercially available thermostatic devices. For increased sensitivity, an exposed bimetal disc may be specified. A variety of mounting brackets and terminals is available. All versions are UL/CSA and European approved. Potential applications include high temperature control for: * Power supplies * Appliances * Medical equipment * Water heaters * Office automation * Industrial equipment * HVAC equipment Table 5. 2450RC/2450RCH/2455RC Series Standard Temperature Characteristics Operating Temperature Range Tolerance Open Close C [F] C [F] 6 Standard Mean Differential C [F] 0 C to 26 C [32 F to 79 F] 4 [7] 4 [6] 4 [6] 4 [6] 3 [5] 6 [10] 6 [10] 5 [9] 5 [8] 5 [8] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 14 to 16 [25 to 29] 8 to 14 [15 to 24] 27 C to 82 C [80 F to 180 F] 5 [9] 4 [7] 4 [6] 3 [5] 3 [5] 3 [5] 8 [15] 6 [11] 6 [10] 6 [10] 5 [9] 5 [8] 45 to 56 [81 to 100] 34 to 45 [61 to 80] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 8 to 16 [15 to 29] 83 C to 110 C [181 F to 230 F] 6 [10] 5 [8] 4 [7] 4 [6] 4 [6] 4 [6] 8 [15] 8 [15] 7 [12] 6 [10] 5 [9] 5 [8] 45 to 56 [81 to 100] 35 to 45 [61 to 80] 28 to 34 [50 to 60] 22 to 27 [40 to 49] 17 to 22 [30 to 39] 8 to 16 [15 to 29] www.honeywell.com/sensing Table 6. 2450RC/2450RCH/2455RC Series Standard Temperature Characteristics (continued) Standard Mean Differential Operating Temperature Range Tolerance C [F] Open Close C [F] C [F] 7 [12] 10 [18] 45 to 56 [81 to 100] 5 [9] 8 [15] 34 to 45 [61 to 80] 111 C to 149 C 5 [8] 7 [12] 28 to 34 [50 to 60] [231 F to 300 F] 4 [7] 7 [12] 22 to 27 [40 to 49] 4 [7] 6 [11] 17 to 22 [30 to 39] 4 [7] 6 [10] 14 to 16 [25 to 29] 150 C to 170 C [301 F to 335 F] 8 [15] 6 [10] 6 [10] 6 [10] 11 [20] 11 [20] 8 [15] 7 [12] 39 to 45 [71 to 80] 34 to 39 [61 to 70] 28 to 33 [50 to 60] 22 to 27 [40 to 49] 171 C to 220 C [336 F to 425 F] 14 [25] 11 [20] 8 [15] 14 [25] 11 [20] 11 [20] 51 to 56 [91 to 100] 39 to 50 [71 to 90] 28 to 39 [50 to 70] 221 C to 235 C [426 F to 450 F] 14 [25] 11 [20] 8 [15] 14 [25] 11 [20] 11 [20] 51 to 56 [91 to 100] 39 to 50 [71 to 90] 28 to 39 [50 to 70] 236 C to 260 C [451 F to 500 F] 14 [25] 11 [20] 14 [25] 11 [20] 31 to 56 [60 to 100] 28 to 50 [50 to 90] Table 7. 2450RC/2450RCH/2455RC Series Specifications Characteristic Switch type Reset type Amperage Voltage Operating temperature range Environmental exposure range Materials: Base Contacts Terminals Closure Brackets Approvals Weight Parameter SPST automatic See Tables 8, 9 120 Vac to 250 Vac 0 C to 260 C [32 F to 500 F] -20 C to 287 C [0 F to 550 F] ceramic silver alloy plated steel aluminum, brass, or stainless steel stainless steel * 2450RCH: 1,59 mm [0.0625 in] clearance through air and over surface; UL File E36103; CSA File LR21048 * 2450RC: 1,59 mm [0.0625 in] clearance; UL file E36103; CSA File LR21048 * 2455RC: 6,35 mm [0.25 in] clearance; UL File E36103; CSA File LR21048 6 g [0.21 oz] (does not include brackets or wire leads) Honeywell Sensing and Control 7 Commercial Thermostats Table 8. 2450RCH/2450RC Contact Ratings Life Cycles 100,000 30,000 120 Vac 15 A resistive 125 VA pilot duty 240 Vac 10 A resistive 125 VA pilot duty 120 Vac 15 A resistive 4.4 FLA 26.4 LRA 125 VA pilot duty 240 Vac 10 A resistive 2.2 FLA 13.2 LRA 125 VA pilot duty Table 9. 2455RC Contact Ratings Life Cycles 100,000 100,000 100,000 Note: Additional contact ratings are available, please contact Honeywell. Figure 5. 2450RC/2450RCH/2455RC Basic Dimensions 2450RC 2450RCH 8 www.honeywell.com/sensing 2455RC Figure 6. 2455RM/2450CM Series Phenolic or Ceramic Manual Reset Thermostats The 2455RM (phenolic)/2450CM (ceramic) Series is a single pole, single throw, snap-acting, non-adjustable thermostat. A temperature-sensitive bimetal disc, electrically and thermally isolated from the switch, is used to actuate the normally-closed contacts. Contacts open when surface or ambient temperatures increase to the operating set point of the calibrated bimetal disc. The entire switch is enclosed in a housing; the bimetal disc is retained by a metal heatconducting end cap. The circuit remains open above the room ambient temperature until the manual reset button is depressed. Due to the small size of this unit and the inherently low mass of the bimetal snap-action disc, response of this thermostat to temperature changes is extremely rapid, compared to other commercially available thermostatic devices. For increased sensitivity, an exposed bimetal disc may be specified. A variety of mounting brackets and terminals is available. All versions are UL/CSA, European approved. Potential applications include those where a manual reset is desired, including: * * * * * * * Power supplies Appliances Medical equipment Water heaters Office automation Industrial equipment HVAC equipment Table 10. 2455RM Series Standard Temperature Characteristics Operating Temperature Range 52 C to 93 C [125 F to 200 F] 94 C to 121 C [201 F to 250 F] 122 C to 150 C [251 F to 302 F] Tolerance C [F] 5 [8] 6 [10] 7 [12] Table 11. 2450CM Series Standard Temperature Characteristics Operating Temperature Range 52 C to 93 C [125 F to 200 F] 94 C to 121 C [201 F to 250 F] 122 C to 149 C [251 F to 300 F] 150 C to 177 C [301 F to 350 F] 177 C to 204 C [351 F to 400 F] 205 C to 232 C [401 F to 450 F] Tolerance C [F] 5 [8] 6 [10] 7 [12] 8 [15] 10 [18] 11 [20] Honeywell Sensing and Control 9 Commercial Thermostats Table 12. 2455RM/2450CM Series Specifications Characteristic Switch type Reset type Amperage Voltage Operating temperature range Environmental exposure range Materials: Base Contacts Terminals Closure Brackets Approvals Weight Parameter SPST manual 15 A resistive at 6,000 cycles (UL); 16 A resistive at 1000 cycles (EU) 120 Vac to 250 Vac 2455RM: 52 C to 150 C [125 F to 302 F] 2450CM: 52 C to 232 C [125 F to 450 F] 2455RM: -20 C to 177 C [0 F to 350 F] 2450CM: -20 C to 260 C [0 F to 500 F] 2455RM: phenolic; 2450CM: ceramic silver alloy 2455RM: unplated brass, plated brass or steel; 2450CM: plated steel aluminum, brass, or stainless steel stainless steel UL File E36103, CSA File LR21048 6 g [0.21 oz] (does not include brackets or wire leads) NOTICE * 2455RM/2450CM thermostats are intended as a manual reset control. They are not to be used on applications where a limit thermostat is required unless back-up protection is provided. Units have been tested by UL for 1,000 cycles under load, 5,000 cycles no load, and are not considered as limit devices. * This range of thermostats has an automatic reset function with manual override function. * Reset pin operation should not be performed above 70% of set point temperature. Table 13. 2450CM/2455RM Contact Ratings Life Cycles 6,000 6,000 120 Vac 15 A resistive 4.4 FLA 26.4 LRA 125 VA pilot duty Note: Additional contact ratings are available, please consult Honeywell. Figure 7. 2455RM/2455CM Basic Dimensions 2455RM A Maximum travel of reset button on contact opening B On contact closing C Reset button 10 www.honeywell.com/sensing 2450CM 240 Vac 10 A resistive 2.2 FLA 13.2 LRA 125 VA pilot duty Figure 8. 2455RD Series Phenolic Manual Reset The 2455RD Series is a single pole, single throw, snapacting, non-adjustable thermostat. A temperature-sensitive bimetal disc, electrically and thermally isolated from the switch, is used to actuate the normally-closed contacts. Contacts open when surface or ambient temperatures increase to the operating set point of the calibrated bimetal disc. The entire switch is enclosed in a housing; the bimetal disc is retained by a metal heat-conducting end cap. The circuit remains open above the room ambient temperature until the manual reset button is depressed. (These devices are constructed with an additional steel disc so that they are manual reset only. They do not have an automatic reset.) Due to the small size of this unit and the inherently low mass of the bimetal snap-action disc, response of this thermostat to temperature changes is extremely rapid, compared to other commercially available thermostatic devices. For increased sensitivity, an exposed bimetal disc may be specified. A variety of mounting brackets and terminals is available. All versions are UL/CSA and European approved. Potential applications include those where a manual reset is desired, including: * * * * * * * Power supplies Appliances Medical equipment Water heaters Office automation Industrial equipment HVAC equipment Table 14. 2455RD Series Standard Temperature Characteristics Operating Temperature Range 52 C to 93 C [125 F to 200 F] 94 C to 121 C [201 F to 250 F] 122 C to 150 C [251 F to 302 F] Tolerance C [F] 5 [8] 6 [10] 7 [12] Honeywell Sensing and Control 11 Commercial Thermostats Table 15. 2455RD Series Specifications Characteristic Switch type Reset type Amperage Voltage Operating temperature range Environmental exposure range Materials: Base Contacts Terminals Closure Brackets Approvals Parameter SPST manual 15 A resistive at 6,000 cycles (UL); 16 A resistive at 1000 cycles (EU) 120 Vac to 250 Vac 2455RD: 52 C to 150 C [125 F to 302 F] 2455RD: -20 C to 177 C [0 F to 350 F] phenolic silver alloy unplated brass, plated brass or steel aluminum, brass, or stainless steel stainless steel UL File E36103, CSA File LR21048 Table 16. 2455RD Contact Ratings Life Cycles 6000 120 Vac 15 A resistive Note: Additional contact ratings are available, please consult Honeywell. Figure 9. 2455RD Basic Dimensions A Maximum travel of reset button on contact opening B On contact closing C Reset button 12 www.honeywell.com/sensing 240 Vac 10 A resistive Figure 10. Series 2455RBV Overmolded Automatic Reset Thermostats The 2455RBV Series has a temperature-sensitive bimetal disc, electrically and thermally isolated from the switch that is used to actuate the normally closed contacts. The contacts open when surface or ambient temperatures increase to the operating set point of the calibrated bimetal disc. The entire switch is enclosed in a phenolic or ceramic housing; the bimetal disc is retained by a metal heatconducting end cap. The unit is then encapsulated in epoxy. This series is UL/CSA and European approved. Potential applications include: * Automotive * Industrial equipment * HVAC Table 17. 2455RBV Series Standard Temperature Characteristics Operating Temperature Range Tolerance Standard Mean Differential C [F] Open C [F] Close C [F] -12,2 C to 26,7 C [10 F to 80 F] 4 [7] 3 [6] 3 [5] 6 [10] 4 [8] 4 [8] 17 to 44 [30 to 80] 14 to 28 [25 to 50] 11 to 22 [20 to 40] 27,2 C to 105 C [81 F to 221 F] 3 [6] 3 [5] 6 [10] 4 [8] 17 to 44 [30 to 80] 11 to 28 [20 to 50] Honeywell Sensing and Control 13 Commercial Thermostats Table 18. 2455RBV Series Specifications Characteristic Switch type Reset type Amperage Voltage Operating temperature range Environmental exposure range Materials: Boot Base Contacts Terminals Closure Brackets Approvals Weight Parameter SPST automatic see Table 19 120 Vac to 250 Vac 0 C to 105 C [32 F to 221 F] -18 C to 126.6 C [0 F to 260 F] nylon, with epoxy filled or injection molded internal 2455RC ceramic or 2455R phenolic silver alloy plated steel with wires aluminum, brass, or stainless steel stainless steel UL File SA4469, CSA File LR21048. 6.5 g [0.23 oz] (does not include brackets or wire leads) Table 19. 2455RBV Series Contact Ratings Life Cycles 100,000 6,000 100,000 120 Vac 15 A resistive 5.8 FLA 34.8 LRA 4.4 FLA 26.4 LRA 125 VA pilot duty 240 Vac 10 A resistive 2.9 FLA 17.4 LRA 2.2 FLA 13.2 LRA 125 VA pilot duty Note: Additional contact ratings are available, please contact Honeywell. Figure 11. 2455RBV Basic Dimensions B A B 18,54 [0.730] 17,27 DIA. [0.680] A Specify wire gauge and insulation B Specify dimension 14 www.honeywell.com/sensing 0,020 [0.51] Figure 12. 2450A/2455RA Heat Detection Thermostats The 2450A/2455RA Series is a single pole, single throw, snap-acting, non-adjustable thermostat designed for easy mounting in devices such as fire alarms, security devices and smoke detectors. A temperature-sensitive bimetal disc, electrically and thermally isolated from the switch, is used to actuate the normally-closed contacts. Contacts open when surface or ambient temperatures increase to the operating set point of the calibrated bimetal disc. Devices are UL recognized and designed for use in both photoelectric and ionization type smoke detectors. Thermostats are available with and without collectors and meet UL spacing requirements for 15 ft, 30 ft and 50 ft. They are available to open or close on a temperature rise of 47 C [117 F] to 107 C [225 F]. Devices feature gold contacts for low voltage requirements and are epoxy sealed at the cap and terminal for long storage life of the application. Collectors are available in silver, black, beige, gold or bronze finishes. All versions are UL approved. Potential applications: * Smoke alarm/heat detectors in industrial, residential and commercial NOTICE Final approval of a fire detection system is determined by UL as outlined in UL #521 and UL #217 for the suitability of the combination of the thermostat (2450A/2455RA) and the user's mounting base, together with its intended application of the total fire detection system. To assist the use with design and testing , a minimum of 0.25 in extension beyond the housing is recommended. Table 20. 2450A/2455RA Series Standard Temperature Characteristics Detection (Close on Rise) Close C [F] Open C [F] Release (Open on Rise) Open C [F] Close C [F] 47 3 [1175] 30 min [85 min] 57 3 [117 5] 30 min [85 min] 57 3 [135 5] 32 min [90 min] 57 3 [135 5] 32 min [90 min] 69 3 [156 5] 32 min [90 min] 69 3 [156 5] 32 min [90 min] 85 4 [185 7] 32 min [90 min] 85 4 [185 7] 32 min [90 min] 107 4 [225 7] 32 min [90 min] 107 4 [225 7} 32 min [90 min] Notes: * Additional switches can be provided as long as they fall between 47,2 C to 107,2 C [117 F to 225 F] close on rise or open or rise. * Please consult Honeywell for tolerances and temperatures not listed. Honeywell Sensing and Control 15 Commercial Thermostats Table 21. 2450A/2455RA Series Specifications Characteristic Switch type Reset type Amperage Voltage Operating temperature range Environmental exposure range Materials: Base Contacts Terminals Closure Brackets Approvals Weight Parameter SPST automatic 3A 120 Vac 47,2 C to 107,2 C [117 F to 225 F] -0 C to 150 C [32 F to 302 F] phenolic gold flash unplated brass, plated brass aluminum aluminum UL File S1015 and S1389; Guide USCV2 and TAOZ2, UL Standard #521, #217 6 g [0.21 oz] (does not include brackets) Figure 13. 2450A/2455RA Basic Dimensions 2450A Figure 14. 2450A/2455RA Collector B247 16 www.honeywell.com/sensing 2455RA Figure 15. 2450A and 2455RA Spacing 2450A: 4,6 m [15 ft] 2455RA with B247A: 15,2 m [50 ft] Figure 16. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" Thermostats The 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" is a single pole, single throw, snapacting, non-adjustable thermostat designed as a high limit device for applications where automatically resettable thermostats are not desirable. A temperature-sensitive bimetal disc, electrically and thermally isolated from the switch, is used to actuate the normally-closed contacts. Contacts open when surface or ambient temperatures increase to the operating set point of the calibrated bimetal disc. The entire switch is enclosed in a housing; the bimetal disc is retained by a metal heat-conducting end cap. The circuit remains open above the room ambient temperature and will reset below -35 C [-31 F]. For increased sensitivity, an exposed disc may be specified. A variety of mounting brackets and terminals is available. All versions are UL/CSA approved and European approved. Potential applications include: * Power supplies * Appliances * Medical equipment * Water heaters * Office automation * Industrial equipment * HVAC equipment Table 22. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" Standard Temperature Characteristics Operating Temperature Range 52 C to 93 C [125 F to 200 F] 94 C to 121 C [201 F to 250F] 122 C to 149 C [251 F to 300 F] 150 C to 177 C [301 F to 350 F] 177 C to 204 C [351 F to 400 F] 205 C to 232 C [401 F to 450 F] 232 C to 260 C [451 F to 500 F] Tolerance C [F] 5 [8] 6 [10] 7 [12] 8 [15] 10 [18] 11 [20] 14 [25] Honeywell Sensing and Control 17 Commercial Thermostats Table 23. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" Specifications Characteristic Switch type Reset type Amperage Voltage Operating temperature range Environmental exposure range Materials: Base Contacts Terminals Closure Brackets Approvals Weight Parameter SPST One Shot see Table 24 120 Vac to 250 Vac 2450R/2455R/2450HR/2450RCH: 52 C to 150 C [125 F to 302 F] 2450RC/2455RC: 52 C to 260 C [125 F to 500 F] 2450R/2455R/2450HR/2450RCH: 17.8 C to 177 C [0 F to 350 F] 2450RC/2455RC: 17.8 C to 287 C [125 F to 550 F] phenolic or ceramic silver alloy unplated brass, plated brass or steel aluminum, brass, stainless steel stainless steel UL File E36103, CSA File LR43279 6 g [0.21 oz] (does not include brackets or lead wires) Table 24. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" Contact Ratings Cycles 1 120 Vac 15 A resistive 240 Vac 10 A resistive Notes: * Resets below -35 C [-31 F]. * Additional contact ratings are available. Please consult Honeywell. Figure 17. 2450R/2455R/2450RC/2455RC/2450HR/2450RCH Series "One Shot" Basic Dimension 2450R/22450RC "One Shot" 2455R/2455RC "One Shot" 2450HR "One Shot" 18 www.honeywell.com/sensing 2450RCH "One Shot" 277 Vac 10 A resistive REDI-TEMP THERMOSTATS REDI-TEMP thermostats are pre-configured as shown and are readily available. Figure 18. 3455RC REDI-TEMP Series (See page 6 for specifications and potential applications.) 3455RC B203S Moveable Bracket 23,80 [0.937] 32,26 [1.270] 2X 3,56 DIA [0.140] 17,55 [0.691] 2X 1,7 DIA [0.067] 31,19 [1.228] 11,9 [0.469] 0.51 [0.20] Table 25. 3455RC REDI-TEMP Series Open on Rise Catalog Listing Close Tolerance C [F] Table 26. 3455RC REDI-TEMP Series Close on Rise Open Temp. C [F] Open Tolerance C [F] Close Temp. C [F] Catalog Listing Close Temp. C [F] Close Tolerance C [F] Open Temp. C [F] Open Tolerance C [F] 3455RC-100-220 18 [65] 3 [5] -1 [30] 5 [8] 3455RC-100-243 3455RC-100-221 24 [75] 3 [5] 4 [40] 5 [8] 21 [70] 5 [8] 2 [35] 3 [5] 3455RC-100-222 29 [85] 3 [5] 13 [55] 5 [8] 3455RC-100-244 32 [90] 5 [8] 16 [60] 3 [5] 3455RC-100-245 43 [110] 5 [8] 27 [80] 3 [5] 3455RC-100-223 35 [95] 3 [5] 18 [65] 5 [8] 3455RC-100-246 54 [130] 5 [8] 38 [100] 3 [5] 3455RC-100-224 41 [105] 3 [5] 3455RC-100-225 46 [115] 3 [5] 24 [75] 5 [8] 3455RC-100-247 66 [150] 5 [8] 49 [120] 3 [5] 29 [85] 5 [8] 3455RC-100-226 52 [125] 3455RC-100-248 77 [170] 5 [8] 60 [140] 3 [5] 3 [5] 35 [95] 5 [8] 3455RC-100-249 88 [190] 5 [8] 71 [160] 3 [5] 3455RC-100-227 3455RC-100-228 57 [135] 3 [5] 41 [105] 5 [8] 3455RC-100-250 99 [210] 5 [8] 82 [180] 4 [6] 63 [145] 3 [5] 46 [115] 5 [8] 3455RC-100-251 110 [230] 5 [8] 93 [200] 4 [6] 3455RC-100-229 68 [155] 3 [5] 52 [125] 5 [8] Note: Materials and contact ratings are the same as those for 2455RC. 3455RC-100-230 73 [165] 3 [5] 57 [135] 5 [8] 3455RC-100-231 79 [175] 3 [5] 63 [145] 5 [8] 3455RC-100-232 85 [185] 3 [5] 68 [155] 5 [8] 3455RC-100-233 91 [195] 3 [5] 73 [165] 5 [8] 3455RC-100-234 96 [205] 4 [6] 79 [175] 5 [8] 3455RC-100-235 102 [215] 4 [6] 85 [185] 5 [8] 3455RC-100-236 107 [225] 4 [6] 91 [195] 5 [8] 3455RC-100-237 113 [235] 4 [6] 96 [205] 5 [8] 3455RC-100-238 118 [245] 4 [6] 102 [215] 5 [8] 3455RC-100-239 124 [255] 4 [7] 107 [225] 5 [8] 3455RC-100-240 135 [275] 4 [7] 118 [245] 5 [8] 3455RC-100-241 146 [295] 4 [7] 129 [265] 5 [8] 3455RC-100-242 157 [315] 6 [10] 135 [275] 8 [15] Honeywell Sensing and Control 19 Commercial Thermostats MOUNTING HARDWARE Figure 19. Brackets B-201, B-201A, B-201B B-203, B-203A, B-203B B-205, B-205A Stationary Surface Movable Surface Air Stream B-203S B-206 A Enclosed B Exposed B-207 3,96 [0.156] 43,05 [1.695] 34,11 [1.343] 25.40 DIA [1.000] B-209 B-210 B-212, B-212A 8,71 R [0.343] 12,70 [0.500] 3,18 [0.125] B-213 20 www.honeywell.com/sensing B-230 11,10 [0.437] 2X 3,73 DIA [0.147] B-239 Figure 19. Brackets (Continued) B-246 B-249 B-250 B-264 Figure 20. Brass Mounting Studs B-220: 6-32 B-221: 8-32 B-222: 10-24 B-223: 10-32 B-224: M3X0.5 B-225: M4X0.7 B-226: M5X0.8 B-227: M6X1.0 A Undercut to minor diameter B-327 B240 6-32 8-32 10-32 M3X0.5 M4X0.7 M5X0.8 B Specify length B-901 4,1 [0.062] C Specify thread B-902 5,0 [0.17] M4 X 0.7 Honeywell Sensing and Control 21 Commercial Thermostats Figure 21. Terminals T-101 T-103 T-106 T-107 Horizontal Solder Special Vertical Solder Inside Vertical Solder Outside T-120 T-141 T-146 T-147 Special Horizontal Weld 1/4 in Quick Connect, Horizontal 1/4 in Quick Connect, Vertical 34,93 [1.375] 15,85 [0.624] 25,40 [1.000] 4,90 DIA [0.193] 1,70 DIA [0.067] 8,64 [0.340] 1,32 [0.052] 3,86 [0.152] 4.57 [0.180] 6.10 [0.240] T-149 T-150 terminal thickness = 0.5 mm [0.020 in] terminal thickness = 0.5 mm [0.020 in] T-161 T-162 T-164 T-165 T-168 T-169 T-170 T-178 T-148 1/4 in Quick Connect, 45 1,70 DIA [0.067] 3/16 in Quick Connect, Flat 3/16 in Quick Connect. Vertical T-151 3/16 in Quick Connect, 45 27,59 [1.086] 45 6,16 [0.242] 12,70 [0.500] 62,18 [2.448] 3,18 [0.125] 2,79 [0.110] 22 www.honeywell.com/sensing 1,27 [0.050] Figure 21. Terminals (Continued) T-179 T-188 T-806 T-807 Vertical Weld Inside Vertical Weld Outside T-849 T-850 T-899 terminal thickness = 0.8 mm [0.032 in] terminal thickness = 0.8 mm [0.032 in] 12,90 [0.508] T-846 2,54 [0.100] 3/16 in Quick Connect, Flat Horizontal 32,5 [1.28] 3/16 in Quick Connect, Vertical 4,9 [0.19] 8,7 [0.34] A A = 2X threaded for M3 screw Honeywell Sensing and Control 23 WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. * WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 009053-2-EN IL50 GLO Printed in USA September 2009 Copyright (c) 2009 Honeywell International Inc. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: 2450CM 00020410 2450CM 00820670 2450CM 00950158 2450CM 02150037 2450CM 05170009 2450CM 80020577 2450CM 80020620 2450CM 80020671 2450CM 80020691 2450CM 80040416 2450CM 80820817 2450CM 80821030 2450CM 81000460 2450CM 82090117 2450CM 82090123 2450CM 83250021 2450CM 86750001 2450CMG81840033 2450CMG86980002 2450CMN80821029 2450HR 00010484 2450RC 00040225 2455RBV01170246 2455RBV01170281 2455RBV81170399 2455RBV82290018 2455RBV83630009 2455RC 00580071 2455RC 00820321 2455RC 80820961 2455RC 81740206 2455RC260040208 2455RC350020533 2455RC350020675 2455RC350020697 2455RC350040503 2455RC350040506 2455RC350040508 2455RC350040510 2455RC350580177 2455RC350950201 2455RC350950223 2455RC356380025 2455RC356780014 2455RM 80820759 2455RM 80980239 2455RM 82850114 2455RM 82850115 2455RMG81460089 2455RC-91000373 2450CM 00580076 2455R--90140921 2455R--01000076 2455R--90020515 2455R--90040874 2455R--00820716 2455R--00820923 2455R--00820715 2455R--90980116 2455R--00820712 2455R--90980491 2455R--09300015 2455R--90750872 2455R--00750822 2455R--01490979 2455R--90820462 2455R--03260915 2455R--04170909 2455R--03260911 2455R--94090904 2455R--01000073 2455R--01000075 2455R--99030011 2455R--90980437 2455R--01000086 2455R--00820191 2455R--01000078 2455R--94280011 2455R--93260812 2455R--90020674 2455R--00980928 2455R--00820714 2455R--00980790 2455R--00820235 2455R--90820464 2455R--09130070 2455R--01000849 2455RC-90820465 2455R--01000079 2455R--90820365 2455R--01000089 2455R--90820461 2455R--01360906 2455R--90980459 2455R--95000900 2455R--91470925 2455R--90870290 2455R--90820463 2455R--79580026 2455R--02980850