120
G6RN PCB Relay
Heavy-duty Miniature Relay
Incorporate s environment- fr ie ndl y, cadmium- free
contacts.
Variety of contact forms: SPDT or SPST-NO
(continuous current rating: 8 A)
Mechanical and electrical characteristics comply
with VDE0435.
Satisfies VDE0700 requirements with a dielectric
strength of 4 kV at a distance of 8 mm.
Satisfies C/250 insulation requirements of
VDE0110.
Tracking resistance: CTI>250
Conforms to class II, part 1 of VDE0106.
Ordering Information
Model Number Le gend
1. Number of Poles
1: 1 pole
2. Contact Form
None: SPDT
A: SPST-NO
3. Contact Material
None: AgNi + gold plating ( 0.35 µ)
ANI: AgNi
ACD: AgCdO + gold plating (0.35 µ)
CDM: AgCdO
AP4: AgNi + gold plating ( 4 µ)
4. Rated Coil Voltage
5, 12, 24, 48 VDC
R
C
VDE
X
Classification Enclosure ratings Contact material Contact form
SPST-NO SPDT
Standard Fully sealed AgNi + gold plating ( 0.35 µ) G6RN-1A G6RN-1
AgNi G6RN-1A-ANI G6RN-1-ANI
AgCdO + gold plating (0.35 µ) G6RN-1A-ACD G6RN-1-ACD
AgCdO G6RN-1A-CDM G6RN-1-CDM
AgNi + gold plating ( 4 µ) G6RN-1A-AP4 G6RN-1-AP4
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G6RN-1A 24 VDC
G6RN-
@@
-
@
@
VDC
1 2 3 4
121
G6RNG6RN
Specifications
Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Contact Ratings
Note: Electrical life expectancy is reduced.
Characteristics
Approved Standards
IEC255 (Inc ludes Reinfor ced Insulation and Spacing Requirements According to IEC65, 335-1, 950,
EN60335- 1, 609 50)
Note: VAC according to IEC417.
Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC
Rated current 44 mA 18.3 mA 9.2 mA 5.2 mA
Coil resistance 114
W
655
W
2,620
W
9,210
W
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 110% of rated voltage at max. temperature (at 85°C)
Power consumption Approx. 220 mW Approx. 250 mW
Load Resistance load (cos
f
= 1)
Rated load 8 A at 250 VAC: 5 A at 30 VDC
Rated carry current 8 A
Max. switching voltage 250 V AC; 30 VDC, (400 VAC) (see note)
Max. switching current AC 8 A; DC 5 A
Max. switching power 2,000 VA; 150 W
Failure rate (reference value) 5 VDC 10 mA (for gold plating 0.35 µ min.)
Operate time Approx. 6 ms
Release time Approx. 3 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 360 operations/hr (under rated load)
Insulation resistance 1,000 M
W
min. (at 500 VDC)
Dielectric strength 4,000 VAC between coil and contacts
1,000 VAC between contacts
Creepage/clearance 8 mm min. between coil and contacts
Vibration resistance Malfunction: NO: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
NC: 10 to 55 t o 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Endurance Mechanical: 10,000,000 operations min.
Electrical: Approx. 100,000 operations
Ambient temperature Operating:
-
40°C to 85°C (with no ic ing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 9 g
Protection class II according to VDE0106 Part 1
Insulation class C/250, B/380 according to VDE0110
Standard Contact form Coil ratings Contact ratings Conditions
IEC255-1-00
IEC255-0-20 SPDT
SPST-NO 5, 6, 12, 18, 24,
36, 48 VDC 8 A at 250 VAC (cos
f
= 1)
(see note) Pollution degree: 3
Overvoltage category: II
Operating range: class 1
Pick-up class: class C
Ambient temperature:
-
40°C to 85°C
122
G6RNG6RN
VDE
UL508 (File No. E41515)
CSA C22.2 (File No. LR31928-543)
Engineering Data
Standard Contact form Coil ratings Contact ratings Condi tion s
VDE0435 Part201
VDE0435 Part120 SPDT
SPST-NO 5, 6, 12, 18, 24,
36, 48 VDC 8 A at 250 VAC (cos
f
= 1) Insulation group according to VDE0110
C/250, B/380
Operating range: class 1
Pick-up class: class C
Ambient temperature:
-
40°C to 85°C
Coil rati ng Contact rating
5 to 48 VDC 10 A at 250 VAC (resistive)
5 A at 30 VDC (resistive)
8 A at 250 VAC (resistive) (ambient temperature: 85°C)
Coil rati ng Contact rating
5 to 48 VDC 10 A at 250 VAC (resistive)
5 A at 30 VDC (resistive)
8 A at 250 VAC (resistive) (ambient temperature: 85°C)
Maximum Switching Power
Switching current (A)
Switching Voltage (V)
Ambient Temperature vs Maximum Coil Voltage
Maximum coil voltage (%)
Ambient Temperature (°C)
200
180
160
150
140
130
120
110
100
80
0
0 10 20 23 30 40 50 60 70 80 90 100
5 10 30 50 100 300 500 1000
0.1
1
5
10
50
100
DC resistive load AC resistive load
1
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Endurance
Endurance (x 10
3
operations)
Switching Current (A)
1000
10
0
500
300
100
50
30
246810
30 VDC resistive
load
250 VAC resistive load
250 VAC induction
load (cosf=0.4)
123
G6RNG6RN
Dimensions
Note: All units are in millimeters unless otherwise indicated.
3.2
19
Five, 1.3-dia. holes
7.62
3.2
1.19
1.6
1.5
28.8 max.
(28.5)*
19 7.62
3.5
0.5
5.1
1.6
15.3 max.
(15.0)*
10.5 max.
(10.0)*
*Average value.
15.3 max.
(15.0)*
28.8 max.
(28.5)*
19
3.2
10.5 max.
(10.0)*
7.62
3.5
0.5
3.2
1.6
SPDT Type
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
12
543
Orientation
mark
SPST-NO Type
12
53
Orientation
mark
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
19
Four, 1.3-dia. holes
5.1
7.62
1.19
1.6 2.8
*Average value.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K096-E1-2A