REV. Status REVISION 12/02/03 YS REVISION A ADDED RoHS & UPDATED LABELS 03/01/06 MP REVISION B CHG TUV FILE # WAS 810/89 (EN60950 & VDE 0551). CLARIFIED PIN OUTS 04/23/07 YS REVISION C UPDATE LOGOS TO STD IED. Dielectric Withstand WAS HiPot 3500. Volt Reg WAS 23%. 4-30-08 EB REVISION D UPDATED SAFETY 09/29/11 MP REVISION E SAFETY NOTES ADDED 03/20/13 MP TOLERANCES (mm) < 44 0.2 4s 20+ 0.3 20 s 50+ 0.4 PREPARED BY: THREE FLANGE DUAL PRIMARY 30VA PC BOARD POWER TRANSFORMER A. Electrical Specifications (@ 25 C) Maximum Power: 30VA Primary Voltage and Frequency: 115/230VAC 50/60Hz Secondary RMS Rating: See Table A Voltage Regulation: 19% TYP @ full load to no load Temperature Rise(normal op. cond.): 55C TYP (70C MAX). A 10% Input Voltage change will proportionally affect transformer sec voltage. The max. allowed wdg temp under abnormal condition is 155C Insulation Resistance: 100MQ MIN @ 500VDC, Pri to Sec, Pri to Core, Sec to Core Dielectric Withstand: 3750Vrms 1 minute @ Pri to Sec 1500Vrms 1 minute @ Pri to Core, Sec to Core B. Marking: includes input and output ratings (per sheet 2), C. Safety: Conforms to construction requirement of: UL50851, 2; CSA No. 66.1, 66.2 (from Datecode 1143 and onwards). UL506, UL1411 MODEL NUMBER PL30-XX-130B | o N 9 aAWNS Part (See tabulation) z 2 UL1446(CLASS 130(B)) Ge TAY EN61558-1, 2-6 QY Safety cerificate file reference: Output UL E138028, E79781, 92957 (See tabulation) CSA 175561 Fuse Rating TUV (P.S.) 4478013415698 (See tabulation) Non shortcircuit proof safety isolating transformer. Intended for mounting on PCBs and for building into end useequipment. Not intended for series/parallel connection with other transformers. Date code and D. Mechanical Specifications: country of origin 41.00[1.614]MAX S--F-F 41__ m I 1.1440.127[0.04540.005] ||- L_ 4.75[0.187]MIN SQUARE 8 PLACES Clearance holes for 440 (M3) MS #2.87[0.13]MIN -| 55.6+1.0[2.189+0.039] J 4 Places K O O ell l o |l12 66.7 +15 55.60.38 4|| a || 10 [2.626 +88 | [2.19+0.015] 3|| 2 a || g 1 o I o 7 C 44.540.38[1.752+0.01 s-| NOTE: BOARD WASHING IS NOT RECOMMENDED FOR THESE PARTS. M. PITCHAI ENGINEER: DRAWING CONTROL NO.| REV MODEL DESCRIPTION MODEL SPECIFICATION PA112261 POWER M_ PITCHAI ACAD/MXFMR/A1 12261 1.DWG E TRANSFORMER P L3 O _ Xx Xx _ 1 3 O B SAFETY ENGINEER CONTENTS OF THIS DRAWING ARE TAMURA CORPORATION OF AMERICA B OCONNELL |PRIOR NOTICE oo RT EN TRE: Baie eee Re sat 920281 DIM: mmlin] SCL: 1/1 | SH 1 OF 2 APPROVED: PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH TAMURA RETAINS THE EXCLUSIVE RIGHT OF DISSEMINATION, REPRODUCTION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS SUBMITTED IN P BRUNE CONFIDENCE FOR CONSIDERATION BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY GRANTED IN WRITING.REV. Status REVISION PREPARED BY: E. Mounting Footprint: co 7 9 | 10 12 eS TOO ~ ~ ~ ao; _ Het rE I \ | | Zz ss 42.740.38[ 1.68140.015] | | | | =| 74 MOUNTING CENTERS al Oo o| 4 Ss} _3 QA testa at = |_ 14.040.38[0.551+0.015] 7.00.38[0.27640.015] 14.040.38[0.551+0. F. Schematic Diagram: 14.040.38[0.5510.015] PRIMARY INPUT CONNECTIONS SERIES PARALLEL CONNECTION CONNECTION 6 PRI SEC 12 ; O O _ co || Loo 230VAC we o o 50/60Hz lL 50/60Hz 30 4 fo Ak. 1 O7 SECONDARY OUTPUT CONNECTIONS PARALLEL SERIES SERIES CONNECTION PRI SEC CONNECTION CONNECTION WITH _CENTERTAP 6 <__ <___ AC 4 OUTPUT o- I AC CT O OUTPUT OUTPUT __}+ AC 5 OUTPUT o G. Table A: T= Time lag SECONDARY PART NO. PARALLEL SERIES SERIES WITH CT OUTPUT |FUSE REOD AC VOLTS|RMS AMPSIAC VOLTSIRMS AMPS} = AC VOLTS [RMS AMPS EA. WINDING PL30-10-130B] 5.0 | 6.00 | 10.0 | 3.00 | 5.0-CT5.0 | 3.00 |2X5.0V | T 3.154 PL30-12-130B] 6.3 | 4.80 | 12.6 | 2.40 | 6.3-CT-6.3 | 2.40 | 2X6.3V | T 2.50A PL30-16-130B} 8.0 3.80 | 16.0 1.90 8.0CT-8.0 1.90 |2X8.0V | T 2.00A PL3020-130B}] 10.0 3.00 | 20.0 1.50 | 10.0CT10.0 | 1.50 | 2X10.0V| T 1.60A PL3024-130B] 12.0 2.00 | 24.0 1.25 |12.0CT12.0 | 1.25 |2X12.0V| T 1.25A PL3028-130B| 14.0 | 2.12 | 28.0 | 1.06 |14.0-CT14.0 | 1.06 | 2X14.0V| T 1.254 M. PITCHAI PL3036-130B| 18.0 1.64 | 36.0 0.82 |18.0CT18.0 | 0.82 |2X18.0V| T 1.00A ENGINEER: DRAWING CONTROL NO.]| REV MODEL DESCRIPTION MODEL SPECIFICATION PA112261 POWER M_ PITCHAI ACAD/MXFMR/A1 12261 2.DWG E TRANSFORMER P | 3 O _ Xx xX _ | 3 O B SAFETY ENGINEER CONTENTS OF THIS DRAWING ARE TAMURA CORPORATION OF AMERICA B OCONNELL | PRIOR NoTICE 040 SOHNE SEN ORME, 7100_FSCONDIDO, CA 92029) Dim: mmtin] SCL: 1/1 | SH: 20F 2 APPROVED: PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH TAMURA RETAINS THE EXCLUSIVE RIGHT OF DISSEMINATION, REPRODUCTION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS SUBMITTED IN P BRUNE CONFIDENCE FOR CONSIDERATION BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY GRANTED IN WRITING.