(Voltages relative to ground.)
Voltage Range on VCC..........................................-0.5V to +6.0V
Voltage Range on PDN............................ -0.5V to (VCC + 0.5V)*
Operating Temperature Range........................... -20°C to +85°C
Storage Temperature Range............................. -55°C to +125°C
Lead Temperature (TDFN only; soldering, 10s)..............+300°C
Soldering Temperature (reflow).......................................+260°C
*Not to exceed +6.0V.
(TA = -20°C to +85°C, unless otherwise noted.)
(VCC = 2.7V to 3.6V, TA = -20°C to +85°C, unless otherwise noted.)
(VCC = 2.7V to 3.6V, TA = -20°C to +85°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Voltage VCC (Note 1) 2.7 3.6 V
High-Level Input Voltage (PDN)VIH 0.7 x VCC VCC + 0.3 V
Low-Level Input Voltage (PDN)VIL -0.3 0.3 x VCC V
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
High-Level Output Voltage (OUT) VOH IOH = -4mA, VCC = MIN VCC -
0.4 V
Low-Level Output Voltage (OUT) VOL IOL = 4mA 0.4 V
High-Level Input Current (PDN)IIH VCC = 3.6V 1 µA
Low-Level Input Current (PDN)IIL VIL = 0V -1 µA
Supply Current (Active) ICC VCC = 3.6V, CL = 15pF, fO = 133MHz 15 24 mA
Standby Current (Power-Down) ICCQ Power-down mode 10 µA
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Output Frequency Range
Available fO133.3 MHz
Output Frequency Tolerance VCC = 3.3V, TA = +25°C (Note 2) -0.3 +0.3 %
Voltage Frequency Variation Over voltage range, TA = +25°C (Note 3) -0.35 +0.35 %
Temperature Frequency Variation
Over temperature
range, VCC = 3.3V
(Notes 4, 5)
-20°C to +25°C -0.7 +0.7
%
+25°C to +85°C -0.5 +0.5
Frequency Variation Over Voltage
and Temperature Over voltage and temperature range -1.0 +1.0 %
O
O
f
f
∆
V
O
f
f
∆
T
O
f
f
∆
V,T
O
f
f
∆
DS1088C Fixed-Frequency EconOscillator™
www.maximintegrated.com Maxim Integrated
│
2
Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Recommended Operating Conditions
DC Electrical Characteristics
Oscillator Characteristics—TDFN