https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) 3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 4 ... 20 mA, output signal: 0 ... 10 V, push-in connection technology Product Description Standard signal 3-way signal conditioner with plug-in connection technology for the electrical isolation, conversion, amplification, and filtering of standard signals. The measuring transducer supports fault monitoring and NFC communication. Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 100.000 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 110.5 mm Depth 120.5 mm Ambient conditions Ambient temperature (operation) -40 C ... 70 C Ambient temperature (storage/transport) -40 C ... 85 C Input data 11/01/2018 Page 1 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Technical data Input data Number of inputs 1 Configurable/programmable no Current input signal 4 mA ... 20 mA Input resistance current input approx. 63 (+ 0.7 V for test diode) Output data Number of outputs 1 Configurable/programmable no Voltage output signal 0 V ... 10 V Max. output voltage 11 V Short-circuit current < 15 mA Load/output load voltage output 10 k Ripple < 20 mVPP (at 10 k) Power supply Nominal supply voltage 24 V DC Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Typical current consumption 25 mA (24 V DC) 54 mA (12 V DC) Power consumption 200 mW (at 9.6 V DC) Connection data Connection method Push-in connection Single conductor/terminal point, solid, with ferrule, min. 0.14 mm Single conductor/terminal point, solid, with ferrule, max. 2.5 mm Single conductor/terminal point, solid, without ferrule, min. 0.14 mm Single conductor/terminal point, solid, without ferrule, max. 2.5 mm Conductor cross section flexible min. 0.14 mm Conductor cross section flexible max. 2.5 mm Min. AWG conductor cross section, flexible 24 Max. AWG conductor cross section, flexible 12 Stripping length 10 mm General No. of channels 1 Maximum transmission error 0.1 % (of final value) Maximum temperature coefficient 0.01 %/K Temperature coefficient, typical 0.01 %/K 11/01/2018 Page 2 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Technical data General Limit frequency (3 dB) approx. 30 Hz Step response (10-90%) approx. 10 ms Protective circuit Transient protection Electrical isolation Reinforced insulation in accordance with IEC 61010-1 Overvoltage category II Degree of pollution 2 Rated insulation voltage 300 V (effective) Test voltage, input/output/supply 3 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color gray Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 Certificate of classification DNV GL 14445-15HH Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Designation Conducted interferences Standards/regulations EN 61000-4-6 Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Standards/regulations EN 61000-4-2 11/01/2018 Page 3 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Technical data Standards and Regulations Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Reinforced insulation in accordance with IEC 61010-1 Conformance CE-compliant ATEX II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Pictogram Block diagram Sensor / Field OUT IN TI- + 1 OUT 1 I+ 5 + OUT U+ IN I+ 5 4-wire OUT 2 I- - 2 + 3 - 4 IN I- OUT U- PWR+ PWR+ PWR- 6 - 6 7 + PWR- 8 - FM PWR- PWR+ US PLC / DCS Zone 2 11/01/2018 Page 4 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Pictogram IN I U OUT FM POWER Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210100 eCl@ss 6.0 27210100 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121008 Approvals Approvals 11/01/2018 Page 5 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Approvals Approvals GL / UL Listed / cUL Listed / EAC / cULus Listed Ex Approvals ATEX / UL Listed / cUL Listed / cULus Listed Approval details GL http://exchange.dnv.com/tari/ 14445-15 HH UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 EAC cULus Listed EAC-Zulassung Accessories Accessories Device marking Marker for end clamp - UCT-EM (30X5) - 0801505 Marker for end clamp, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm 11/01/2018 Page 6 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Accessories Marker for end clamp - UCT-EM (30X5) YE - 0830340 Marker for end clamp, Sheet, yellow, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm Plastic label - UC-EMLP (15X5) - 0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - UC-EMLP (15X5) YE - 0822615 Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - UC-EMLP (15X5) SR - 0828095 Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - US-EMLP (15X5) - 0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm 11/01/2018 Page 7 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Accessories Plastic label - US-EMLP (15X5) YE - 0828873 Plastic label, Card, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - US-EMLP (15X5) SR - 0828874 Plastic label, Card, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm DIN rail connector DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Evaluation unit Monitoring module - MINI MCR-2-FM-RC - 2904504 Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Screw connection technology, standard configuration Monitoring module - MINI MCR-2-FM-RC-PT - 2904508 Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Push-in connection technology, standard configuration 11/01/2018 Page 8 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Accessories Labeled device marker Marker for end clamp - UCT-EM (30X5) CUS - 0801589 Marker for end clamp, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm Marker for end clamp - UCT-EM (30X5) YE CUS - 0830348 Marker for end clamp, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm Plastic label - UC-EMLP (15X5) CUS - 0824550 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - UC-EMLP (15X5) YE CUS - 0824551 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - UC-EMLP (15X5) SR CUS - 0828099 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm 11/01/2018 Page 9 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Accessories Plastic label - US-EMLP (15X5) CUS - 0830076 Plastic label, can be ordered: By card, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - US-EMLP (15X5) YE CUS - 0830077 Plastic label, can be ordered: By card, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm Plastic label - US-EMLP (15X5) SR CUS - 0830078 Plastic label, can be ordered: By card, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm Power module Power terminal block - MINI MCR-2-PTB - 2902066 Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Screw connection technology Power terminal block - MINI MCR-2-PTB-PT - 2902067 Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Push-in connection technology 11/01/2018 Page 10 / 11 https://www.phoenixcontact.com/us/products/2902003 Signal conditioner - MINI MCR-2-I4-U-PT - 2902003 Accessories Power supply Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A Power supply unit - MINI-PS-100-240AC/24DC/1.5/EX - 2866653 Primary-switched power supply MINI POWER for DIN rail mounting, input: 1-phase, output: 24 V DC/1,5 A, for the potentially explosive area Terminal marking Marker strip - SK 5,0 WH:REEL - 0805221 Marker strip, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL 2.0, THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, mounting type: adhesive, for terminal block width: 5 mm, lettering field size: continuous x 5 mm DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GY - 2695439 DIN rail connector (TBUS), 5-pos., for bridging the supply voltage, can be snapped onto NS 35/... DIN rails according to EN 60715 Phoenix Contact 2018 (c) - all rights reserved http://www.phoenixcontact.com 11/01/2018 Page 11 / 11