General-purpose Basic Switch Z CSM_Z_DS_E_3_1 Best-selling Basic Switch Boasting High Precision and Wide Variety * A large switching capacity of 15 A with high repeat accuracy. * A wide range of variations in contact form for your selection: basic, split-contact, maintained-contact, and adjustable contact gap types. * A series of standard models for micro loads is available. * A series of molded terminal-type models incorporating safety terminal protective cover is available. Be sure to read Safety Precautions on page 22 and Safety Precautions for All Basic Switches. Model Number Structure Configuration Basic models Refer to page 3. General-purpose Drip-proof Without terminal protective cover Refer to page 5. With terminal protective cover Refer to page 5. Molded terminal Refer to page 2. Split-contact models General-purpose Refer to page 4. Maintained-contact models General-purpose Refer to page 4. Basic Models General-purpose * A variety of actuators is available for a wide range of application. * The contact mechanism of models for micro loads is a crossbar type with gold-alloy contacts, which ensures highly reliable operations for micro loads. * Contact Gap: H2: 0.20 mm (extra-high-sensitivity) H: 0.25 mm (high-sensitivity, micro voltage current load) G: 0.5 mm (standard) E: 1.8 mm (high-capacity) F: 1.0 mm (split-contact models) Drip-proof * These Switches use a rubber boot on the actuator and adhesive fill between the case and cover to increase resistance to drips. * Models with drip-proof terminal protective covers and molded terminals with resin filling are also available. Split-contact Models * This type is identical in construction to the general-purpose basic switch except that it has two pairs of simultaneous acting contacts by splitting moving contacts. * Since the moving contacts are connected to a common terminal, either parallel or series connection is possible. * Highly reliable micro load switching is ensured if the model is used as a twin-contact switch. Maintained-contact Models * The maintained-contact type has a reset button at the bottom of the switch case, in addition to the pushbutton (plunger) located on the opposite side of the reset button. Use these buttons alternately. * Since the Switch has greater pretravel than overtravel, it is suitable for use in reversible control circuits, manual reset circuits, safety limit circuits, and other circuits which are not preferable for automatic resetting. (For further details, refer to individual datasheets.) 1 Z Model Number Legend Basic Models Standard Models (Drip-proof Type/Molded Terminals) Z-@@@@-@ Z-@55-M@@ @M (1)(2)(3)(4) (5) (1) Ratings 01 15 : 0.1 A (micro load) : 15 A (2) Contact Gap H2 H G E : 0.20 (extra-high-sensitivity) : 0.25 mm (high-sensitivity, micro load) : 0.5 mm (standard) : 1.8 mm (high-capacity) (3) Actuator None S D K K3 Q3 : : : : : : Q : Q8 Q22 Q21 : : : L L2 W21 W W3 W32 W4 W44 W78 : : : : : : : : : W52 : W22 W2 W25 W49 W54 W2277 : : : : : : M M22 : : M2 NJ NJS : : : Pin plunger Slim spring plunger Short spring plunger Spring plunger (medium OP) Spring plunger (high OP) Panel mount plunger (medium OP) Panel mount plunger (medium OP) Panel mount plunger (high OP) Panel mount roller plunger Panel mount cross roller plunger Leaf spring (high OF) Roller leaf spring Short hinge lever Hinge lever (low OF) Hinge lever (medium OF) Hinge lever (high OF) Low-force hinge lever Long hinge lever Low-force wire hinge lever (low OF) Low-force wire hinge lever (high OF) Short hinge roller lever Hinge roller lever Hinge roller lever (large roller) Short hinge cross roller lever Hinge cross roller lever Unidirectional short hinge roller lever (low OF) Reverse hinge lever Reverse short hinge roller lever Reverse hinge roller lever Flexible rod (high OF) Flexible rod (low OF) (1) (2)(3) (4) (1) Drip-proof Type (2) Lead Outlets None 19 : VSF : VCT (3) Directions of Lead Outlets (See following L Type diagrams.) L R D D Type R Type : Left : Right : Descending (4) Length of Lead Outlets 1 3 : 1m : 3m Split-contact Models Maintained-contact Models Z-10F@Y-B Z-15-E@R (1) (2)(3)(4) (5) (1) (2)(3)(4) (1) Ratings 10 : 10 A (split-contact models) (2) Contact Gap F : 1 mm (high-capacity) (3) Actuator None S D Q Q22 W W22 W2 M22 : : : : : : : : : Pin plunger Slim spring plunger Short spring plunger Panel mount plunger Panel mount roller plunger Hinge lever Short hinge roller lever Hinge roller lever Reverse short hinge roller lever (1) Ratings 15 : 15 A (2) Contact Gap E : 1.8 mm (high capacity) (3) Actuator None S W : Pin plunger : Slim spring plunger : Hinge lever (4) Structure R : Maintained-contact models (4) Construction Y : Split-contact models (5) Terminals B : Screw terminal (with toothed washer) (4) Degree of Protection None 55 A55 : General-purpose : Drip-proof (not include the terminals) : Drip-proof (including the terminals) (5) Terminals None B B5V : Solder terminal : Screw terminal (with toothed washer) : Screw terminal with terminal cover (for Z-15G@A55 only) Note: For combinations of models, Ordering Information on page 3 to 6. 2 Z Ordering Information Main Unit Basic Models (General-purpose) Classification Actuator Contact gap Terminal *1 Pin plunger Slim spring plunger Short spring plunger Panel mount plunger Standard High-sensitivity G (0.5 mm) Model H (0.25 mm) Model Z-15H2 Z-15E Z-01H Z-15H2-B Z-15E-B Z-01H-B --- --- Z-15GS Z-15HS Z-15GS-B Z-15HS-B Z-15GD Z-15HD Z-15GD-B Z-15HD-B Z-15GQ3 Z-15GQ Z-15HQ Z-15GQ-B Z-15HQ-B High OP Z-15GQ8-B Z-15GQ8 Z-15HQ22 Z-15HQ22-B Panel mount cross roller plunger Z-15GQ21 Z-15HQ21 Z-15GQ21-B Z-15HQ21-B Z-15GL Z-15GL2 Z-15GL2-B Z-15GW21 Z-15GW21-B Lowforce wire hinge lever Z-01HQ Z-01HQ-B --- --- Z-15EQ22 Z-15EQ22-B Z-15EQ21 Z-15EQ21-B ----- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- Z-15HW Medium OP Z-15GW3-B High OP Z-15GW32-B Z-15GW3 --- Z-15GW4 Z-15HW24 Z-15GW4-B Z-15HW24-B Z-15HW78 --- Z-15HW78-B Z-15HW52 Z-15HW52-B Z-15HW22 Z-15GW22-B Z-15HW22-B Short hinge cross roller lever Z-15GW49-B Reverse hinge lever *2 Z-15EQ Z-15EQ-B --- Z-15GW22 Unidirectional short hinge roller lever --- --- Z-15HW-B Z-15GW49 --- Standard Z-15GW2 Z-15HW2 Z-15GW2-B Z-15HW2-B Large roller Z-15GW25-B Z-15GW25 Z-15GW54 Hinge cross roller lever --- --- Short hinge roller lever Hinge roller lever Z-01HD Z-01HD-B --- Z-15GW High OP --- Z-15ED Z-15ED-B --- Z-15GW-B Low OP --- Z-01HS Z-01HS-B --- Low OP Z-15GW32 --- --- Z-15GQ22 Z-15GL-B --- --- Z-15GQ22-B Low-force hinge lever H (0.25 mm) Model Z-15H Panel mount roller plunger Hinge lever E (1.8 mm) Model Z-15H-B Medium OP Short hinge lever Micro load Z-15G Z-15GQ3-B Roller leaf spring High-capacity Z-15G-B Low OP Leaf spring Extra-high sensitivity H2 (0.20 mm) Model Z-15GW54-B ----- Z-15EW22 Z-01HW22 Z-15EW22-B Z-01HW22-B --- --- --- --- --- --- --- ----- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- Z-15GW2277 Parallel Z-15GW2277-B Z-15GM Z-15GM-B Z-15GM22 Reverse short hinge roller lever *2 Z-15GM22-B Reverse hinge roller lever *2 Z-15GM2-B Z-15GM2 *1. : Solder terminal : Screw terminal *2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. Accessories (Terminal Covers, Actuators, and Separators): Refer to Z/A/X/DZ Common Accessories and Z/X/DZ Common Accessories. 3 Z Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification Actuator Short spring plunger Standard High-sensitivity Z-15GD-B --- Panel mount plunger Z-15GQ Z-15GQ-B Z-15GQ8-B --- Panel mount roller plunger Z-15GQ22 Z-15GQ22-B --- Z-15GQ21-B --- Z-15GW21-B --- Z-15GW Z-15GW-B --- Z-15GW4-B Z-15HW24-B --- Z-15HW78-B Short hinge roller lever Z-15GW22 Z-15GW22-B --- Hinge roller lever Z-15GW2 Z-15GW2-B --- Z-15GM22-B --- Z-15GM2-B --- Panel mount cross roller plunger Short hinge lever Hinge lever Low-force hinge lever Low-force hinge wire lever Reverse short hinge roller lever Reverse hinge roller lever Split-contact Models Actuator Pin plunger Slim spring plunger Short spring plunger Minimum order lot (pcs) 10 Maintained-contact Models Contact gap Terminal *1 F (1.0 mm) Model --Z-10FY-B Actuator Pin plunger Model Z-15ER Slim spring plunger Z-15ESR Hinge lever Z-15EWR --Z-10FSY-B --Z-10FDY-B --Panel mount plunger Panel mount roller plunger Hinge lever Short hinge roller lever Z-10FQY-B --Z-10FQ22Y-B --Z-10FWY-B --Z-10FW22Y-B --Hinge roller lever Reverse short hinge roller lever *2 Z-10FW2Y-B --Z-10FM22Y-B *1. : Solder terminal : Screw terminal *2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. 4 Z Basic Models (Drip-proof Models Standard, Microload ) Classification Contact gap Drip-proof terminal protective cover Actuator Terminal *1 Pin plunger Panel mount plunger Micro load H (0.25 mm) Not provided Provided Model Model Model --- Z-01H55 Z-15G55-B Z-15GA55-B5V Z-01H55-B Z-15GK55 Low OP Z-15GK55-B High OP Z-15GK355 --- Z-15GK355-B Z-15GK3A55-B5V Z-15GQ55 --- Z-15GQ55-B Z-15GQA55-B5V Z-15GQ2255 --Z-15GQ22A55-B5V Panel mount cross roller plunger --- --- Z-15GQ2155-B Z-15GQ21A55-B5V Short hinge lever Long hinge lever Hinge lever Short hinge roller lever Z-15GL55 Z-15GL55-B Z-15GL255 Z-15GL255-B Z-15GW2155 Z-15GW2155-B Reverse hinge lever *2 ----------- --- --- --- --- --- --- Z-15GW4455 --- Z-15GW4455-B Z-15GW44A55-B5V Z-15GW55 --- Z-15GW55-B Z-15GWA55-B5V ----- Z-15GW2255 --- Z-01HW2255 Z-15GW2255-B Z-15GW22A55-B5V Z-01HW2255-B Z-15GW255 --- Z-15GW255-B Z-15GW2A55-B5V Hinge roller lever Unidirectional short hinge roller lever Z-01HD55-B --- Z-15GQ2255-B Roller leaf spring Z-01HD55 --- Z-15GD55-B Panel mount roller plunger Leaf spring Not provided Z-15G55 Z-15GD55 Short spring plunger Spring plunger Standard G (0.5 mm) Z-15GW227755 --- Z-15GW227755-B Z-15GW2277A55-B5V Z-15GM55 Z-15GM55-B Z-15GM2255 Reverse short hinge roller lever *2 Z-15GM2255-B Reverse hinge roller lever *2 Z-15GM255-B Z-15GM255 --- --- --- --- --- --- --- --- --- --- Z-15GNJ55 Flexible rod (coil spring) *3 Z-15GNJ55-B *1. : Solder terminal : Screw terminal *2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. *3. The tip is made of resin. Minimum Order Lot The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification Actuator Contact gap Standard G (0.5 mm) Short spring plunger Z-15GD55-B Spring plunger Z-15GK55-B Minimum order lot (pcs) Z-15GW4455-B Hinge lever Z-15GW55 Z-15GW55-B Short hinge roller lever 10 Z-15GW2255 Z-15GW2255-B Hinge roller lever Z-15GW255-B Flexible rod (coil spring) Z-15GNJ55-B Accessories (Terminal Covers, Actuators, and Separators): Refer to Z/A/X/DZ Common Accessories and Z/X/DZ Common Accessories. 5 Z Basic Models (Drip-proof Models High-sensitivity ) Classification Contact gap Drip-proof terminal protective cover Actuator Terminal * The following models are available at the minimum order lot specified below. Orders must be placed per lot. Classification High-sensitivity Minimum order lot (pcs) Actuator Contact gap H (0.25 mm) High-sensitivity H (0.25 mm) Not provided Model Z-15HNJS55 Flexible rod (steel wire) * Minimum Order Lot Flexible rod (steel wire) Z-15HNJS55-B 10 Z-15HNJS55-B : Solder terminal : Screw terminal Specifications Ratings (Basic, Split-contact and Maintained contact Models) Z-15 (Except Micro Load and Flexible Rod Models) Item Contact gap G, H, H2, E G H, H2 E Non-inductive load (A) Resistive load Lamp load Rated voltage 125 VAC 250 VAC 500 VAC * 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC NC NO 15 (10) * 15 (10) * 10 15 15 6 0.5 0.25 15 15 2 0.4 0.2 15 15 15 0.75 0.3 NC NO 3 2.5 1.5 3 3 3 0.5 0.25 3 3 2 0.4 0.2 3 3 3 0.75 0.3 1.5 1.25 0.75 1.5 1.5 1.5 0.5 0.25 1.5 1.5 1.4 0.4 0.2 1.5 1.5 1.5 0.75 0.3 Z-01H Inductive load (A) Inductive load Motor load NC NO 15 (10) * 15 (10) * 6 15 10 5 0.05 0.03 15 10 1 0.03 0.02 15 15 10 0.4 0.2 NC NO 5 3 1.5 5 5 5 0.05 0.03 5 5 1 0.03 0.02 5 5 5 0.4 0.2 2.5 1.5 0.75 2.5 2.5 2.5 0.05 0.03 2.5 2.5 1 0.03 0.02 2.5 2.5 2.5 0.4 0.2 * Figures in parentheses are for the Z-15HW52, Z-15HW78(-B) and Z-15H2(-B) models, the AC ratings of these models are 125 and 250 V only. Rated voltage 125 VAC 8 VDC 14 VDC 30 VDC Resistive load (A) NC NO 0.1 0.1 0.1 0.1 Note: 1. The above current ratings are the values of the steady-state current. 2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. 5. The normally closed and normally open ratings of reverse hinge lever models are opposite to each other. 6. The AC ratings of molded terminals are 125 and 250 V only. 7. The ratings values apply under the following test conditions: (1) Ambient temperature: 202C (2) Ambient humidity: 655%RH (3) Operating frequency: 20 operations/min Z-15 (Flexible Rod Models) 125 VAC 250 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC Non-inductive load (A) Resistive load Lamp load NC NO NC NO 15 2 1 15 1 0.5 1 2 15 1 2 15 1 2 2 0.4 0.4 0.4 0.2 0.2 0.2 Inductive load (A) Inductive load Motor load NC NO NC NO 7 2.5 2 5 1.5 1 1.5 3 7 1.5 3 7 0.5 1 1 0.03 0.03 0.03 0.02 0.02 0.02 Use the switch within the operating range. Voltage (V) Rated voltage 5 mW 800 mW 0.16 mA 30 26 mA 24 Micro load area Z-01H Standard load area Z-15H, H2 Z-15G Z-15E Z-10FY Z-15ER Z-10F Item Contact gap Series connection Parallel connection Rated voltage 125 VAC 250 VAC 30 VDC 125 VDC 250 VDC 125 VAC 250 VAC 30 VDC 125 VDC 250 VDC Non-inductive load (A) Resistive load Lamp load NC NO 10 10 10 1 0.6 6 6 6 0.6 0.3 NC 4 2.5 4 1 0.6 3 2.5 4 0.6 0.3 NO 2 1.5 2 1 0.6 1.5 1.25 2 0.6 0.3 Inductive load (A) Inductive load Motor load NC NO 6 6 6 0.1 0.05 4 4 4 0.1 0.05 NC 5 3 6 0.1 0.05 4 2 6 0.1 0.05 NO 2.5 1.5 3 0.1 0.05 2 1 3 0.1 0.05 12 Unusable range 5 0 0.1 1 mA 1 100 mA 160 mA 10 100 1,000 Current (mA) Minimum applicable load Z-01H Z-15@, Z-10FY 5 VDC 1 mA 5 VDC 160 mA 6 Z Certified Standard Ratings Ask your OMRON representative for information on certified models. TUV (EN61058-1) UL/CSA (General ratings only) Rated Model voltage 125 VAC 250 VAC 480 VAC 30 VDC 125 VDC 250 VDC Z-15 Z-10F Z-01H 15A 1/8HP 15A 1/4HP 15A --0.5A 0.25A 6A 1/10HP 6A 1/8HP 6A --0.6A 0.3A 0.1A ----0.1A ----- Rated Model voltage 250 VAC 125 VAC 30 VDC Z-15H@ Z-15G@ Z-01H@ 15 A ----- 15 A ----- --0.1 A 0.1 A Z-15H@ Z-15G@ Z-01H@ 15 A ----- 15 A ----- --0.1 A 0.1 A CCC (GB14048.5) Rated Model voltage 250 VAC 125 VAC 30 VDC Characteristics Classification Operating speed Mechanical Operating frequency Electrical Insulation resistance Contact resistance Z-15 (except micro Z-01H Z-15 (flexible rod) Z-10F Z-15H2 load and flexible rod) 0.01 mm to 1 m/s *1 1 mm to 1 m/s 0.1 mm to 1 m/s *1 0.01 mm to 1 m/s 240 operations/min 120 operations/min 240 operations/min 240 operations/min 20 operations/min 100 M min. (at 500 VDC) 15 m max. (initial value) 50 m max. (initial value) 15 m max. (initial value) 25 m max. (initial value) 15 m max. (initial value) Between contacts of same polarity Between contacts of same polarity Between contacts of Between contacts of same Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap G: 1,000 VAC, 50/60 Hz for 1 same polarity polarity Contact gap H: 600 VAC, 50/60 Hz for 1 min min 600VAC, 50/60Hz for Contact gap F: 1,500 VAC, Dielectric strength Contact gap E: 1,500 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min 50/60 Hz for 1 min 1min Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min 10 to 20 Hz, 1.5-mm double Vibration 10 to 55 Hz, 1.5-mm double amplitude *5 Malfunction 10 to 55 Hz, 1.5-mm double amplitude *5 amplitude *5 resistance 2 Destruction 1,000 m/s max. Shock resistance Malfunction 300 m/s2 max. *2 *5 50 m/s2 max. *5 300 m/s2 max. *3 *5 100 m/s2 max. Contact gap H2: 10,000,000 operations min. 500,000 operations 20,000,000 operations 1,000,000 operations min. Mechanical Contact gap G, H: 20,000,000 operations min. min. *1 min. Contact gap E: 300,000 operations Durability 100,000 operations 500,000 operations Contact gap G, H: 500,000 operations min. 100,000 operations min. Electrical min. min. Contact gap E: 100,000 operations min. General-purpose IP00 Degree of protection Drip-proof Equivalent to IP62 (except terminals) Degree of protection Class I against electric shock Proof tracking index 175 (PTI) Ambient operat- General-purpose -25C to 80C (with no icing) ing temperature Drip-proof -15C to 80C (with no icing) Ambient operat- General-purpose 35% to 85%RH ing humidity Drip-proof 35% to 95%RH Weight Approx. 22 to 58 g Approx. 42 to 48 g Approx. 34 to 61 g Approx. 22 g Item *1. *2. *3. *4. *5. The values are for the plunger models. (For the lever models, the values are at the plunger section.) (Consult your OMRON representative for other models.) The values are for the Z-15G pin plunger. The values are for the Z-10FY-B. The values are for the pin plunger. The durability for models other than the pin plunger is 10,000,000 min. Malfunction: 1 ms max. Contacts Specification Item Classification Contacts Inrush current Z-15 Z-01H Shape Rivet Single crossbar Z-10F Rivet Material Silver Gold alloy Silver NC 30 A max. 0.1 A max. 40 A max. NO 15 A max. 0.1 A max. 20 A max. Engineering Data 10,000 Ambient temperature: 202C Ambient humidity: 655%RH Without load Operating frequency: 240 operations/min 5,000 3,000 1,000 Electrical Durability (Z-15G) Durability (x104 operations) Durability (x104 operations) Mechanical Durability (Z-15G) 5,000 Ambient temperature: 202C Ambient humidity: 655%RH Operating frequency: 20 operations/min. 3,000 125 VAC cos dia. = 1 125 VAC cos dia. = 0.4 1,000 500 250 VAC cos dia. = 1 250 VAC cos dia. = 0.4 300 500 100 300 50 500 VAC cos dia. = 1 30 100 500 VAC cos dia. = 0.4 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Overtravel (mm) 0 2 4 6 8 10 12 14 16 Switching Current (A) 7 Z Structure Split-contact Models Basic Models Contact Form Contact Form (SPDT) COM NC NC NO COM NO Note: The Z-15GM is a reversible model and the NO and NC positions are reversed. NC NO Note: The NO and NC terminal arrangement is reversed for Models with reverse operation (Z-10FM). Molded Terminals COM (Black) (Red) NC Connection Example (White) NO ( ) indicates wire color. Series Connection Parallel Connection Note: The Z-15GM is a reversible model and the NO and NC positions are reversed. Structure Drip-proof Construction * Without Terminal Protective Cover Rubber boot Fixed contact (b) Movable spring Glued surface (adhesive is filled between case and cover) Movable contact Spring pivot Fixed contact (a) Maintained-contact Models Contact Form COM NC NO * With Terminal Protective Cover Rubber boot (weather-resistive chloroprene is used) Pushbutton for resetting Stainless-steel stopper (improves sealing) Rubber packing (improves sealing between switch housing and terminal cover) Terminal protective covers are sold separately for maintenance purposes, which can be, however, used with the Z-@-B5V models only. For details, refer to page 24. 8 Z Dimensions (Unit: mm) Mounting When mounting the Switch to a panel, use a tightening torque of 2.94 to 4.9 N*m for the hexagonal nuts on the actuator. Use M4 screws with plane washers and spring washers to mount the Switch. Tighten each mounting screw securely to a torque of 1.18 to 1.47 N*m. Panel Mount Plunger Two, 4.2 dia. mounting holes or M4 Panel Mount Roller Plunger 12.5+0.2 0 dia. 12.5 +0.2 0 dia. 5 +0.2 0 25.4 0.1 13 +0.2 0 Basic Models General-purpose and Split-contact Models Terminals Basic Models Screw Terminals (-B) Split-contact Models Solder Terminal (-A) ("-A" is not included in the model numbers.) Screw Terminals (Y-B) 5.6 6.4 9.2 11.9 25.4 0.1 20 17.45 0.2 23 17.45 0.2 3 2 49.2 Three, M4 x 5.5 Terminal screws (with toothed washer) 3 2 NO COM NC NC 1 17.450.2 1 NC NC NO NO COM COM 17.1 NO 20 11.9 Five, M3.5 x 5.5 terminal screws (with toothed washer) Appropriate terminal screw tightening torque: 0.49 to 0.78 N*m. Note: With reverse action models (Z-10FM), the positions of NO and NC terminals are reversed. 49.2 Appropriate terminal screw tightening torque: 0.78 to 1.18 N*m. Note: With reverse action models (Z-15GM), the positions of NO and NC terminals are reversed. Dimensions and Operating Characteristics The models, illustrations, and graphics are for screw-terminal models (-B). The "-A" at the end of the model number for solder terminal models has been omitted. For details of the terminals, see above. Pin Plunger Z-15G-B Z-15E-B Z-15H2-B Z-01H-B Z-15H-B Z-10FY-B 2.3 dia. PT 23.3 0.25 4.2 +0.075 -0.025 dia. hole 2.3SR * OP 24.2 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 * Stainless-steel plunger 11.9 49.2 Operating Characteristics Operating force Release force Pretravel Overtravel Movement Differential RF PT OT MD Model Z-15G-B Z-15H2-B Z-15H-B Z-15E-B Z-01H-B Z-10FY-B OF min. max. min. max. 2.45 to 3.43 N 1.12 N 0.4 mm 0.13 mm 0.05 mm 1.96 to 2.5 N 1.12 N 0.3 mm 0.13 mm 0.005 to 0.008 mm 1.96 to 2.75 N 1.12 N 0.3 mm 0.13 mm 0.025 mm 6.12 to 7.85 N 1.12 N 0.8 mm 0.13 mm 0.13 mm 2.45 N max. 0.78 N 0.5 mm 0.13 mm 0.04 mm 4.46 to 7.26 N 1.12 N 0.8 mm 0.13 mm 0.1 mm Operating Position OP Slim Spring Plunger Z-15GS-B Z-01HS-B Z-15HS-B Z-10FSY-B 15.90.4 mm 5.2 dia. PT 4 dia. 23.3 0.25 * 4.2 +0.075 -0.025 dia. hole OP 9 dia. 24.2 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.45 0.2 11.9 * Stainless-steel plunger (flat, 1R chamfered) 49.2 OF RF PT OT MD OP min. max. min. max. Z-15GS-B Z-15HS-B Z-01HS Z-10FSY-B 2.45 to 3.43 N 1.12 N 0.4 mm 1.6 mm 0.05 mm 1.96 to 2.79 N 1.12 N 0.3 mm 1.6 mm 0.025 mm 2.45 N max. 0.78 N 0.5 mm 1.6 mm 0.05 mm 4.46 to 7.26 N 1.12 N 0.8 mm 1.6 mm 0.1 mm 28.20.5 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 9 Z Short Spring Plunger Z-15GD-B Z-01HD-B Z-15HD-B Z-10FDY-B Z-15ED-B 12.3 dia. 10 dia. 23.3 0.25 12SR * PT 7.15 dia. 4.2 +0.075 -0.025 dia. hole OP 24.2 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 17.45 0.2 * Plated iron plunger 11.9 25.4 0.1 49.2 OF RF PT OT MD min. max. min. max. Z-15GD-B Z-15HD-B Z-15ED-B Z-01HD-B Z-10FDY-B 2.45 to 3.43 N 1.12 N 0.4 mm 1.6 mm 0.05 mm 1.96 to 2.79 N 1.12 N 0.3 mm 1.6 mm 0.025 mm 6.13 to 7.85 N 1.12 N 0.8 mm 1.6 mm 0.13 mm 2.45 N max. 0.78 N 0.5 mm 1.6 mm 0.05 mm 4.46 to 7.26 N 1.12 N 0.8 mm 1.6 mm 0.1 mm OP Panel Mount Plunger Z-15GQ-B Z-01HQ-B Z-15HQ-B Z-10FQY-B Z-15EQ-B Z-15GQ3-B * Z-15GQ8-B * 21.50.5 mm 8.35 dia. 23.3 0.25 11.9SR *1 PT OP 13.1 16.3 *4 16 dia. 4.2 +0.075 -0.025 4.36+0.1 -0.05 dia. * The external dimensions of the actuator vary. OF RF PT OT MD min. max. min. max. 25.4 0.1 49.2 Z-15GQ-B Z-15HQ-B Z-15EQ-B Z-01HQ-B Z-10FQY-B Z-15GQ3-B Z-15GQ8-B 2.45 to 3.43 N 1.12 N 0.4 mm 5.5 mm 0.05 mm 1.96 to 2.79 N 1.12 N 0.3 mm 5.5 mm 0.025 mm 6.13 to 7.85 N 1.12 N 0.8 mm 5.5 mm 0.13 mm 2.45 N max. 0.78 N 0.5 mm 5.5 mm 0.05 mm 4.46 to 7.26 N 1.12 N 0.8 mm 5.5 mm 0.1 mm 2.45 to 3.43 N 1.12 N 4.2 mm 2.5 mm 2.2 mm 2.45 to 3.43 N 1.12 N 0.5 mm 5.5 mm 0.05 mm 18.80.8 mm 32.51 mm OP Panel Mount Roller Plunger Z-15GQ22-B Z-15EQ22-B Z-15HQ22-B Z-10FQ22Y-B Note: 1. Do not use the M12 mounting screw and the case mounting hole at the same time, or excessive pulling force *2 will be imposed on the switch and the case and cover may be damaged. 4.2 +0.075 -0.025 dia. hole *3 2. On the model Z-15GQ3-B, PT can be set to a value larger than that for the Z15GQ. 3. On the model Z-15GQ8-B, operating 9.2 position can be adjusted by providing a screw in the plunger section. 4. On the model Z-15GQ8-B, the M3 hole 17.450.2 11.9 *1. Stainless-steel plunger with a depth of 10 mm is a through *2. Two hexagonal nuts (2 t x 14 width across flats) hole. Take precautions so that no *3. Two lock nuts (2 t x 15.6 width across flats) *4. Incomplete screw part with a maximum length water or screw lock agent penetrates of 1.5 mm. into the hole. M12 x 1 mounting screw 21.80.8 mm 12.7 dia. x 4.8 *1 23.3 0.25 PT *2 OP 15.5 16.3 4.2 +0.075 -0.025 *3 M12 x 1 mounting screw dia. hole 16 dia. Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 11.9 *1. Stainless-steel roller *2. Two hexagonal nuts (3 t x 17 width across flats) *3. Incomplete screw part with a maximum length of 1.5 mm. 49.2 OF RF PT OT MD OP min. max. min. max. Z-15GQ22-B Z-15HQ22-B Z-15EQ22-B Z-10FQ22Y-B 2.45 to 3.43 N 1.12 N 0.4 mm 3.58 mm 0.05 mm 1.96 to 2.79 N 1.12 N 0.3 mm 3.58 mm 0.025 mm 6.13 to 7.85 N 1.12 N 0.8 mm 3.58 mm 0.13 mm 4.46 to 7.26 N 1.12 N 1 mm 3.55 mm 0.1 mm 33.41.2 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 10 Z Panel Mount Cross Roller Plunger Z-15GQ21-B Z-15EQ21-B PT Z-15HQ21-B 23.3 0.25 12.7 dia. x 4.8 *1 OF RF PT OT MD *2 OP 15.5 16.3 M12 x 1 mounting screw 4.2 +0.075 -0.025 dia. hole *3 16 dia. min. max. min. max. Z-15HQ21-B 1.96 to 2.79 N 1.12 N 0.3 mm 3.58 mm 0.025 mm OP 33.41.2 mm 9.2 Z-15EQ21-B 4.2 +0.075 -0.025 OF RF PT OT MD 4.36 +0.1 -0.05 dia. 17.450.2 11.9 25.4 0.1 *1. Stainless-steel roller *2. Two hexagonal nuts (3 t x 17 width across flats) *3. Incomplete screw part with a maximum length of 1.5 mm. 49.2 Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. Leaf Spring Z-15GL-B Z-15GQ21-B 2.45 to 3.43 N 1.12 N 0.4 mm 3.58 mm 0.05 mm min. max. min. max. OP 6.13 to 7.85 N 1.12 N 0.8 mm 3.58 mm 0.13 mm 33.41.2 mm t = 0.3* 4.8 49.6 0.8 4.2+0.075 -0.025 dia. hole FP OP 23.9 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. * Stainless-steel spring lever 49.2 Roller Leaf Spring Z-15GL2-B 1.38 N 0.14 N 1.6 mm 1.3 mm FP max. OP 20.6 mm 17.40.8 mm * When operating, be sure not to exceed 1.6 mm. 17.450.2 11.9 25.4 0.1 OF max. RF min. OT *min. MD max. 9.5 dia. x 4 (plastic toller) 46 0.8 t = 0.3 * 4.2 +0.075 -0.025 dia. hole FP OP 23.9 9.2 4.2+0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.45 0.2 * Stainless-steel spring lever 11.9 26.2 1.38 N 0.14 N 1.6 mm 1.3 mm FP max. OP 31.8 mm 28.60.8 mm * When operating, be sure not to exceed 1.6 mm. 49.2 Short Hinge Lever Z-15GW21-B OF max. RF min. OT *min. MD max. t=1* 4.9 .2R 28 20.2 16.9 13.9 FP OP OF RF OT MD 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 FP max. OP 17.45 0.2 * Stainless-steel lever 11.9 max. min. min. max. 1.57 N 0.27 N 2 mm 1 mm 24.8 mm 190.8 mm 49.2 Hinge Lever Z-15GW-B Z-15GW32-B Z-15HW-B Z-10FWY-B Z-15GW3-B (Lever Length: 56R)* t=1* 63.5 26.2 20.2 16.9 4.9 R 13.9 OP FP 9.2 4.2 +0.075 -0.025 4.2+0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 11.9 17.450.2 * Stainless-steel lever 49.2 * The external dimensions of the actuator vary. Z-15GW-B Z-15HW-B Z-15GW32-B Z-10FWY-B Z-15GW3-B OF RF min. OT min. MD max. 0.69 N max. 0.14 N 5.6 mm 1.27 mm 0.66 N max. 0.14 N 5.6 mm 0.63 mm 1.47 to 1.96 N 0.92 N 5.6 mm 1.27 mm 0.88 N max. 0.14 N 5.6 mm 2.4 mm 0.78 N max. 0.15 N 4.8 mm 1.12 mm FP max. 28.2 mm 27.4 mm 28.2 mm 29.8 mm 27.2 mm OP 190.8 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 11 Z Low-force Hinge Lever Z-15GW4-B t=1* 4.9 R 63.5 26.2 20.2 16.9 PT OP 13.9 OF RF PT OT MD 9.2 4.2 +0.075 -0.025 4.2+0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 11.9 OP * Stainless-steel lever 49.2 Z-15HW24-B max. min. max. min. max. 274 mN 34.3 mN 10 mm 5.6 mm 1.27 mm 190.8mm t = 0.8 * 5 R 12102 0 R 26.2 PT 20.2 16.9 2 OP 13.9 OF RF PT OT MD 9.2 4.2 +0.075 -0.025 4.2+0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 11.9 max. min. max. min. max. OP 58.8 mN 4.90 mN 19.8 mm 10 mm 2 mm 19.81.6 mm * Stainless-steel lever 49.2 Low-force Wire Hinge Lever Z-15HW52-B Z-15HW78-B (Lever Length: 110R) * Z-15HW52-B t=1* 3 max. 3.5R 26.2 6 20.2 16.9 OF RF PT OT MD PT OP 13.9 OP 9.2 4.2 +0.075 -0.025 25.4 0.1 49.2 OF RF PT OT MD * Stainless-steel wire lever max. min. max. min. max. 39.2 mN 2.94 mN 10 mm 6 mm 3 mm OP 201 mm 9.5 dia. x 4 (plastic roller) 26.2 26 .6 R t=1* 191 mm Z-15HW78-B 17.450.2 11.9 Note: AC electrical ratings: 10 A, 125/250 V. Short Hinge Roller Lever Z-15GW22-B Z-01HW22-B Z-15HW22-B Z-10FW22Y-B Z-15EW22-B Z-15GW2-B * Z-15HW2-B * Z-10FW2Y-B * 58.8 mN 4.90 mN 8.3 mm 5.6 mm 0.65 mm 4.2+0.075 -0.025 dia. hole 4.36+0.1 -0.05 dia. * The external dimensions of the actuator vary. max. min. max. min. max. OP 20.2 16.9 FP 13.9 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. * The external dimensions of the actuator vary. (Lever Length: 48.5R) OF RF OT MD max. min. min. max. FP max. OP 4.2 +0.075 -0.025 dia. hole 25.4 0.1 17.450.2 11.9 * Stainless-steel lever 49.2 Z-15GW22-B Z-15HW22-B Z-15EW22-B Z-01HW22-B Z-10FW22Y-B Z-15GW2-B Z-15HW2-B Z-10FW2Y-B 1.57 N 0.41 N 2.4 mm 0.5 mm 1.47 N 0.41 N 2.4 mm 0.45 mm 1.94 N 0.41 N 2.4 mm 1.3 mm 1.57 N 0.27 N 2.4 mm 0.5 mm 2.45 N 0.34 N 2.4 mm 1 mm 0.98 N 0.22 N 4 mm 1.02 mm 0.84 N 0.22 N 4 mm 0.6 mm 1.27 N 0.22 N 4 mm 2 mm 35.1 mm 30.20.4 mm 32.5 mm 30.20.4 mm 34.8 mm 30.20.4 mm 32.5 mm 30.20.4 mm 36.5 mm 30.20.8 mm 37.4 mm 30.20.8 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 12 Z Short Hinge Cross Roller Lever Z-15GW49-B Z-15GW54-B (Lever Length: 48.7R) * 26.2 .1 R 9.5 dia. x 4 (plastic roller) 27 t=1* FP OP 20.2 16.9 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. * The external dimensions of the actuator vary. * Stainless-steel lever 49.2 max. min. min. max. FP max. OP 17.450.2 11.9 25.4 0.1 OF RF OT MD Z-15GW49-B Z-15GW54-B 1.67 N 0.41 N 2.4 mm 0.51 mm 0.98 N 0.22 N 4 mm 1 mm 33.3 mm 310.4 mm 37.3 mm 310.8 mm OF RF OT MD 0.98 N 0.21 N 4 mm 1.6 mm 20 dia. x 4 R2 (plastic roller) Hinge Roller Lever Z-15GW25-B 26.2 R 50 t = 1* FP OP 20.2 16.9 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole FP max. OP 4.36 +0.1 -0.05 dia. 17.450.2 11.9 25.4 0.1 Operating direction 9.5 dia. x 4 (plastic roller) 31 .9R 26.2 t=1* 47.5 mm 41.20.8 mm * Stainless-steel lever 49.2 Unidirectional Short Hinge Roller Lever Z-15GW2277-B max. min. min. max. .1R 11 20.2 16.9 FP OP 34.1 max. OF RF OT MD 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole FP max. OP 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 11.9 t=1* 18.65 OP 13.9 4.9 FP OF RF OT MD 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36+0.1 -0.05 dia. max. min. min. max. FP max. OP 17.450.2 11.9 1.67 N 0.27 N 5.6 mm 0.89 mm 23.8 mm 190.8 mm * Stainless-steel lever 49.2 t=1* Reverse Short Hinge Roller Lever ** Z-15GM22-B Z-10FM22Y-B 43.6 mm 41.30.8 mm 56R 20.2 17.4 25.4 0.1 1.67 N 0.41 N 2.4 mm 0.51 mm * Stainless-steel lever 49.2 Reverse Hinge Lever ** Z-15GM-B max. min. min. max. 9.5 dia. x 4 (plastic roller) 18 .5 R 18.65 OP 20.2 17.4 FP 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 31.8 mm 29.40.4 mm 33 mm 29.40.4 mm OF RF OT MD 2.35 N 0.55 N 4 mm 0.64 mm R OP FP 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 49.2 6.37 N 1.67 N 2 mm 0.56mm .6 40 20.2 17.4 25.4 0.1 Z-10FM22Y-B 5.28 N 1.67 N 2 mm 0.28 mm 9.5 dia. x 4 (plastic roller) t = 1* 18.65 Z-15GM22-B * Stainless-steel lever 49.2 Reverse Hinge Roller Lever ** Z-15GM2-B max. min. min. max. FP max. OP 17.450.2 11.9 OF RF OT MD 11.9 17.450.2 max. min. min. max. FP max. OP 35 mm 30.20.8 mm * Stainless-steel lever ** The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed. Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 13 Z Basic Models (Drip-proof) without Terminal Protective Cover Terminals (Molded Terminals: Refer to page 21.) Without Terminal Protective Cover 9.2 20 20 17.45 0.2 COM NO NC 1 3 2 49.2 Three, M4 x 5.5 Terminal screws (with toothed washer) Note: With reverse action models (Z-15GM), the positions of NO and NC terminals are reversed. Dimensions and Operating Characteristics Pin Plunger Z-15G55-B Z-01H55-B The above illustration is for model without terminal protective cover. 3.9 dia. PT 6SR * 23.3 0.25 4.2 +0.075 -0.025 dia. hole OP 23.9 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 11.9 * Stainless-steel plunger 49.2 OF RF PT OT MD min. max. min. max. Z-15G55-B Z-01H55-B 2.45 to 4.22 N 1.12 N 2.2 mm 0.13 mm 0.06 mm 3.43 N max. 0.78 N 2.2 mm 0.13 mm 0.06 mm OP Short Spring Plunger Z-15GD55-B Z-01HD55-B 15.90.4 mm 15 dia. PT 11.9SR * 23.3 0.25 7.15 dia. 4.2 +0.075 -0.025 dia. hole OP 23.9 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.450.2 11.9 * Stainless-steel plunger 49.2 Spring Plunger Z-15GK55-B OF RF PT OT MD max. min. max. min. max. Z-15GD55-B Z-01HD55-B 5.30 N 1.12 N 1.8 mm 1.6 mm 0.06 mm 3.63 N 0.78 N 1.9 mm 1.6 mm 0.06 mm OP 21.50.5 mm 17 dia. PT 11.9SR * 23.3 0.25 7.15 dia. 4.2 +0.075 -0.025 dia. hole OP 23.9 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.45 0.2 11.9 * Stainless-steel plunger 49.2 Z-15GK355-B OF RF PT OT MD max. min. max. min. max. OP 5.30 N 1.12 N 2.3 mm 1.6 mm 0.06 mm 28.20.5 mm 17 dia. PT 11.9SR * 23.3 0.25 8.35 dia. 4.2 +0.075 -0.025 dia. hole OP 23.5 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 49.2 17.45 0.2 11.9 * Stainless-steel plunger OF RF PT OT MD OP max. min. max. min. max. 5.30 N 1.12 N 2.4 mm 3.5 mm 0.06 mm 37.81.2 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 14 Z Panel Mount Plunger Z-15GQ55-B 8.35 dia. 23.3 0.25 11.9SR *1 PT M12 x 1 Mounting screw *2 OP 13.1 4.2 +0.075 -0.025 dia. hole 16.3 *4 OF RF PT OT MD *3 16 dia. 9.2 4.2 +0.075 -0.025 OP 4.36 +0.1 -0.05 dia. 25.4 0.1 49.2 Panel Mount Roller Plunger Z-15GQ2255-B 5.30 N 1.12 N 1.8 mm 5.5 mm 0.06 mm 21.80.8 mm Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. 17.450.2 11.9 *1. Stainless-steel plunger *2. Two hexagonal nuts (2 t x 14 width across flats) *3. Two lock nuts (2 t x 15.6 width across flats) *4. Incomplete screw part with a maximum length of 1.5 mm. 12.7 dia. x 4.8 *1 23.3 0.25 PT max. min. max. min. max. *2 OP 15.5 16.3 M12 x 1 mounting screw 4.2 +0.075 -0.025 dia. hole *3 16 dia. 9.2 4.36 +0.1 -0.05 dia. 5.30 N 1.12 N 1.8 mm 3.58 mm 0.06 mm 33.41.2 mm Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. 17.450.2 11.9 max. min. max. min. max. OP 4.2 +0.075 -0.025 25.4 0.1 OF RF PT OT MD 49.2 *1. Stainless-steel roller *2. Two hexagonal nuts (3 t x 17 width across flats) *3. Incomplete screw part with a maximum length of 1.5 mm. Panel Mount Cross Roller Plunger Z-15GQ2155-B 23.3 0.25 PT 12.7 dia. x 4.8 *1 *2 OP 15.5 16.3 4.2 +0.075 -0.025 dia. *3 M12 x 1 mounting screw hole 16 dia. 9.2 4.36 +0.1 -0.05 dia. 49.2 *1. Stainless-steel roller *2. Two hexagonal nuts (3 t x 17 width across flats) *3. Incomplete screw part with a maximum length of 1.5 mm. Leaf Spring Z-15GL55-B 5.30 N 1.12 N 1.8 mm 3.58 mm 0.06 mm 33.41.2 mm Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. 17.450.2 11.9 max. min. max. min. max. OP 4.2 +0.075 -0.025 25.4 0.1 OF RF PT OT MD t = 0.3 * 4.8 49.6 0.8 4.2 +0.075 -0.025 dia. hole FP OP 23.9 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 11.9 49.2 17.45 0.2 * Stainless-steel spring lever OF max. RF min. OT *min. MD max. 1.96 N 0.14 N 1.6 mm 1.3 mm FP max. OP 20.6 mm 17.50.8 mm * When operating, be sure not to exceed 1.6 mm. Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 15 Z Roller Leaf Spring Z-15GL255-B 9.5 dia. x 4 (plastic roller) 46 0.8 t = 0.3* 4.2 +0.075 -0.025 dia. hole FP OP 23.9 9.2 4.2 +0.075 -0.025 4.36+0.1 -0.05 dia. 25.4 0.1 49.2 Short Hinge Lever Z-15GW2155-B 26.2 1.96 N 0.14 N 1.6 mm 1.3 mm FP max. OP 31.8 mm 28.60.8 mm * When operating, be sure not to exceed 1.6 mm. 17.45 0.2 * Stainless-steel lever 11.9 OF max. RF min. OT *min. MD max. t = 1* 4.9 .2R 28 20.2 16.9 13.9 OP FP OF RF OT MD 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 FP max. OP 17.450.2 * Stainless-steel lever 11.9 max. min. min. max. 1.86 N 0.27 N 2 mm 1 mm 25 mm 190.8 mm 49.2 Long Hinge Lever Z-15GW4455-B t=1* 4.9 100R 26.2 20.2 16.9 13.9 OP FP 9.2 4.2 +0.075 -0.025 4.2+0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. * Stainless-steel lever 49.2 Hinge Lever Z-15GW55-B max. min. min. max. FP max. OP 17.45 0.2 11.9 25.4 0.1 OF RF OT MD 0.88 N 0.14 N 5.6 mm 3.5 mm 33 mm 191.2 mm t = 1* 4.9 R 63.5 26.2 20.2 16.9 13.9 OP FP 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. max. min. min. max. FP max. OP 17.45 0.2 * Stainless-steel lever 11.9 25.4 0.1 OF RF OT MD 0.98 N 0.14 N 5.6 mm 2 mm 28.2 mm 190.8 mm 49.2 Short Hinge Roller Lever Z-15GW2255-B Z-01HW2255-B 9.5 dia. x 4 (plastic roller) 26.2 26 .6 R t=1* OP 20.2 16.9 FP 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 11.9 49.2 17.450.2 * Stainless-steel lever OF RF OT MD max. min. min. max. FP max. OP Z-15GW2255-B Z-01HW2255-B 1.96 N 0.41 N 2.4 mm 0.8 mm 1.96 N 0.27 N 2.4 mm 0.8 mm 32.9 mm 30.20.4 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 16 Z Hinge Roller Lever Z-15GW255-B 26.2 9.5 dia. x 4 (plastic roller) .5R 48 t=1* OP 20.2 16.9 FP 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36+0.1 -0.05 dia. 25.4 0.1 17.45 0.2 11.9 Unidirectional Short Hinge Roller Lever Z-15GW227755-B max. min. min. max. FP max. OP * Stainless-steel lever 49.2 OF RF OT MD 1.27 N 0.21 N 4 mm 1.6 mm 36.5 mm 30.20.8 mm Operating direction 9.5 dia. x 4 (plastic roller) 31 .9R 26.2 t=1* .1R 11 20.2 16.9 FP OP 34.1 max. 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 Reverse Hinge Lever * Z-15GM55-B * Stainless-steel lever t=1* 18.65 43.6 mm 41.30.8 mm 4.9 OP 13.9 FP 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. * Stainless-steel lever t=1* OF RF OT MD max. min. min. max. FP max. OP 17.45 0.2 11.9 49.2 Reverse Short Hinge Roller Lever * Z-15GM2255-B 1.77 N 0.49 N 2.4 mm 0.8 mm 56R 20.2 17.4 25.4 0.1 max. min. min. max. FP max. OP 17.45 0.2 11.9 49.2 OF RF OT MD 1.96 N 0.27 N 5.6 mm 0.89 mm 23.8 mm 190.8 mm 9.5 dia. x 4 (plastic roller) 18 . 5R 18.65 OP 20.2 17.4 FP 13.9 9.2 4.2 +0.075 -0.025 4.2+0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 25.4 0.1 Reverse Hinge Roller Lever * Z-15GM255-B .6R 40 OP 20.2 17.4 FP 13.9 9.2 4.2 +0.075 -0.025 4.2 +0.075 -0.025 dia. hole 4.36 +0.1 -0.05 dia. 49.2 31.8mm 29.40.4mm 9.5 dia. x 4 (plastic roller) t=1* 25.4 0.1 5.69 N 1.67 N 2 mm 0.28 mm * Stainless-steel lever 49.2 18.65 max. min. min. max. FP max. OP 17.450.2 11.9 OF RF OT MD 11.9 17.45 0.2 OF RF OT MD max. min. min. max. FP max. OP 2.65 N 0.55 N 4 mm 0.64 mm 35 mm 30.20.8 mm * Stainless-steel lever * The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers. Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 17 Z Flexible Rod (Coil Spring) Z-15GNJ55-B *1 6.1 dia. 3.2 dia. PT Nylon rod 30 Operating range *2 38 (111.3) 43.4 12 dia. Rubber cap 23.3 0.25 (13.6) 4.2 +0.075 -0.025 dia. hole 16.3 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 17.45 0.2 11.9 49.2 OF max. PT max. 0.49 N (20 mm) TT max. 40 mm *1. Operation is possible in any direction other than the axial direction (indicated by the arrow ). *2. Use only the area within the top 30 mm of the rod as the operating part. (Do not use the area that falls within 80 mm from the mounting hole as the operating part. Using this area may cause damage to the nylon rod. Flexible Rod (Steel Wire) Z-15HNJS55-B *1 PT 30 Operating range *2 1-dia. stainless steel wire *3 100 0.4 Four, M3 set screws with hexagonal holes (130.1) (22) Rubber cap 12 dia. 23.3 0.25 (13.8) 4.2 +0.075 -0.025 dia. hole OF max. PT max. 0.15 N (25 mm) 16.3 9.2 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 25.4 0.1 11.9 49.2 17.45 0.2 *1. Operation is possible in any direction other than the axial direction (indicated by the arrow ). *2. Use only the area within the top 30 mm of the rod as the operating part. (Do not use the area that falls within 100 mm from the mounting hole as the operating part. Using this area may cause damage to the steel wire.) *3. The steel wire can be replaced if damaged. (Model: Lever for HNJS55) Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 18 Z Basic Models (Drip-proof) with Terminal Protective Cover Dimensions and Operating Characteristics Pin Plunger Z-15GA55-B5V 6SR * PT 3.9 dia. 23.3 0.25 OP 14.7 (11) 4.2 +0.075 -0.025 19.2 4.36 +0.1 -0.05 dia. 25.4 0.1 52.8 13.7 4.2 +0.075 -0.025dia. hole (28.8) Z-15GK3A55-B5V 17.45 0.2 * Stainless-steel plunger OF RF PT OT MD max. min. max. min. max. OP 2.45 to 4.22 N 1.12 N 2.2 mm 0.13 mm 0.06 mm 15.90.4 mm 17 dia. PT 11.9SR * 23.3 0.25 8.35 dia. OP 14.7 (11) 4.2 +0.075 -0.025 19.2 4.36 +0.1 -0.05 dia. 25.4 0.1 13.7 4.2 +0.075 -0.025 dia. hole 52.8 Panel Mount Plunger Z-15GQA55-B5V (28.8) OP 17.45 0.2 5.30 N 1.12 N 2.4 mm 3.5 mm 0.06 mm 37.81.2 mm 8.35 dia. PT 11.9SR *1 23.3 0.25 M12 P = 1 *2 13.1 *3 16 dia. 16.3 (11) 4.2 +0.075 -0.025 19.2 4.36 +0.1 -0.05 dia. 25.4 0.1 13.7 4.2 +0.075 -0.025dia. hole 17.45 0.2 (28.8) *1. Stainless-steel plunger *2. Two hexagonal nuts (2 t x 14 width across flat) *3. Two lock nuts (2 t x 15.6 width across flats) 52.8 PT *2 M12 P = 1 15.5 16 dia. 16.3 (11) 4.36 +0.1 -0.05 dia. 25.4 0.1 13.7 4.2 +0.075 -0.025 dia. hole 52.8 (28.8) OP 21.80.8 mm Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. OF RF PT OT MD max. min. max. min. max. 17.45 0.2 5.30 N 1.12 N 1.8 mm 3.58 mm 0.06 mm 33.41.2 mm Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. *1. Stainless-steel roller *2. Two hexagonal nuts (3 t x 17 width across flats) *2 OP M12 P = 1 15.5 16 dia. OF RF PT OT MD OP (11) 4.2 +0.075 -0.025 19.2 4.36 +0.1 -0.05 dia. 25.4 0.1 5.30 N 1.12 N 1.8 mm 5.5 mm 0.06 mm 12.7 dia. x 4.8 *1 23.3 0.25 16.3 max. min. max. min. max. OP 4.2 +0.075 -0.025 19.2 PT OF RF PT OT MD 12.7 dia. x 4.8 *1 23.3 0.25 OP Panel Mount Cross-roller Plunger Z-15GQ21A55-B5V max. min. max. min. max. * Stainless-steel plunger OP Panel Mount Roller Plunger Z-15GQ22A55-B5V OF RF PT OT MD 13.7 4.2 +0.075 -0.025 dia. hole 52.8 (28.8) 17.45 0.2 *1. Stainless-steel roller *2. Two hexagonal nuts (3 t x 17 width across flats) max. min. max. min. max. 5.30 N 1.12 N 1.8 mm 3.58mm 0.06 mm 33.41.2 mm Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged. Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 19 Z Long Hinge Lever Z-15GW44A55-B5V t=1* 4.9 100R 26.2 20.2 16.9 13.9 OP FP (11) 4.2 +0.075 -0.025 19.2 4.36 +0.1 -0.05 dia. 25.4 0.1 13.7 4.2 +0.075 -0.025 dia. hole 17.45 0.2 (28.8) * Stainless-steel lever 52.8 Hinge Lever Z-15GWA55-B5V OF RF OT MD max. min. min. max. FP max. OP 0.88 N 0.14 N 5.6 mm 3.5 mm 33 mm 191.2 mm t=1* 4.9 R 63.5 26.2 20.2 16.9 13.9 OP FP (11) 4.2 +0.075 -0.025 19.2 13.7 52.8 Short Hinge Roller Lever Z-15GW22A55-B5V max. min. min. max. FP max. OP 4.36 +0.1 -0.05 dia. 25.4 0.1 OF RF OT MD 4.2 +0.075 -0.025 dia. hole 17.45 0.2 (28.8) * Stainless-steel lever t=1* 0.98 N 0.14 N 5.6 mm 2 mm 28.2 mm 190.8 mm 9.5 dia. x 4 (plastic roller) 26 .6 R 26.2 OP 20.2 16.9 FP 13.9 (11) 4.2 +0.075 -0.025 19.2 13.7 4.2 +0.075 -0.025 dia. hole 17.45 0.2 (28.8) * Stainless-steel lever 52.8 Hinge Roller Lever Z-15GW2A55-B5V 26.2 max. min. min. max. FP max. OP 4.36 +0.1 -0.05 dia. 25.4 0.1 OF RF OT MD 1.96 N 0.41 N 2.4 mm 0.8 mm 32.9 mm 30.20.4 mm 9.5 dia. x 4 (plastic roller) .5R 48 t=1* OP 20.2 16.9 FP 13.9 (11) 4.2 +0.075 -0.025 19.2 13.7 4.2 +0.075 -0.025 dia. hole 17.45 0.2 (28.8) * Stainless-steel lever 52.8 Unidirectional Short Hinge Roller Lever Z-15GW2277A55-B5V max. min. min. max. FP max. OP 4.36 +0.1 -0.05 dia. 25.4 0.1 OF RF OT MD 1.27 N 0.21 N 4 mm 1.6 mm 36.5 mm 30.20.8 mm Operating direction 9.5 dia. x 4 (plastic roller) t=1* 31.9 R 26.2 .1R 11 OP 34.1 max. 20.2 16.9 FP 13.9 (11) 4.2 +0.075 -0.025 19.2 max. min. min. max. FP max. OP 4.36 +0.1 -0.05 dia. 25.4 0.1 OF RF OT MD 13.7 52.8 4.2 +0.075 -0.025 dia. hole 17.45 0.2 (28.8) * Stainless-steel lever 1.77 N 0.49 N 2.4 mm 0.8 mm 43.6 mm 41.30.8 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 20 Z Basic Models (Drop-proof) with Modeled terminals Molded Terminals L/R Type (The following illustration is the R type.) D Type c a b 38 a 5 c b a b c Size (mm) Lead wire 12 19 4 11 13 20 VCT Size (mm) Lead wire VSF VCT VSF a b c 12 19 4 11 12 16 Lead Wire Specifications Lead wire Specifications Nominal cross sectional area (mm2) VSF (single-core, vinyl cord) VCT (vinyl-insulated cable) 1.25 Finished outer diameter (mm) Connection to terminal Length (m) Approx. 3.1 dia. Black: COM White:NO Three-core: approx. 10.5 dia. Red: NC 1, 3 Note: 1. No models with molded terminals are approved by UL, CSA, or EN. 2. Molded terminals are not available on all models. Contact your OMRON representative for applicable products. Maintained-contact Models Dimensions and Operating Characteristics Pin Plunger Z-15ER PT 2.3 dia. 23.3 0.25 4.2 +0.075 -0.025 dia. hole 2.3SR *1 OP Reset position 7.1 min. 21.4 6.4 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 14.3 0.3 25.4 0.1 6.4 dia. Reset free position 9.5 max. Reset button *2 11.9 17.45 0.2 Plunger OF max. PT max. OT min. 1.96 to 2.50 N 0.4 mm 0.13 mm OP 15.90.4 mm 49.2 Reset Button NO COM *1. Stainless steel plunger *2. Plastic plunger NC Slim Spring Plunger Z-15ESR PT OF max. OT min. 5.2 dia. 23.3 0.25 *1 4 dia. Plunger 4.2 +0.075 -0.025 dia. hole OP Reset position 7.1 min. 9 dia. 21.4 6.4 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 14.3 0.3 11.9 25.4 0.1 OF max. PT max. OT min. OP 6.4 dia. Reset free position 9.5 max. Reset button *2 17.45 0.2 *1. Stainless steel plunger (tip only, flat, R1 bevel). *2. Plastic plunger 49.2 Hinge Lever Z-15EWR 0.55 to 2.79 N 0.4 mm 2.65 N 0.4 mm 1.6 mm 28.20.5 mm Reset Button OF max. OT min. 2.79 N 0.4 mm t = 1 *1 26.2 63.5 20.2 16.9 4.9 R Lever Tip 13.9 OP FP Reset position 7.1 min. 6.4 4.2 +0.075 -0.025 4.36 +0.1 -0.05 dia. 14.3 0.3 11.9 25.4 0.1 4.2 +0.075 -0.025 dia. hole 49.2 Reset button *2 17.45 0.2 *1. Stainless steel lever *2. Plastic plunger 6.4 dia. Reset free position 9.5 max. OF max. OT min. 0.54 N 5.6 mm FP max. OP 28.2 mm 190.8 mm Reset Button OF max. OT min. 2.94 N 0.4 mm Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 21 Z Safety Precautions Refer to Safety Precautions for All Basic Switches. Precautions for Safe Use Terminal Connection When soldering lead wires to the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than 5 s to solder any part of the Switch. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is applied to any part of the Switch for 5 s or more. * Do not use the switch outside the specified temperature and atmospheric conditions. The permissible ambient temperature depends on the model. (Refer to the specifications in this catalog.) Sudden thermal changes may cause thermal shock to distort the switch and result in faults. Incorrect Correct Operation * Make sure that the switching frequency or speed is within the specified range. 1.If the switching speed is extremely slow, the contact may not be switched smoothly, which may result in a contact failure or contact welding. 2.If the switching speed is extremely fast, switching shock may damage the Switch soon. If the switching frequency is too high, the contact may not catch up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. In order to determine the life of a Switch model to be applied to a particular use, it is best to conduct an appropriate durability test on some samples of the model under actual conditions. * Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 100% of the rated OT. Precautions for Correct Use Mounting Location * Do not use the switch alone in atmospheres such as flammable or explosive gases. Arcing and heat generation associated with switching may cause fires or explosions. * Switches are generally not constructed with resistance against water. Use a protective cover to prevent direct spraying if the switch is used in locations subject to splashing or spurting oil or water, dust adhering. Incorrect Correct Separate the installation location from heat sources. * Mount a cover if the switch is to be installed in a location where worker inattention could result in incorrect operation or accidents. Incorrect Correct (preventing malfunctions) * Subjecting the switch to continuous vibration or shock may result in contact failure or faulty operation due to abrasion powder and in reduced durability. Excessive vibration or shock will cause the contacts to operate malfunction or become damaged. Mount the switch in a location that is not subject to vibration or shock and in a direction that does not subject the switch to resonance. * If silver contacts are used with relatively low frequency for a long time or are used with microloads, the sulfide coating produced on the contact surface will not be broken down and contact faults will result. Use a microload switch that uses gold contacts. * Do not use the switch in atmospheres with high humidity or heat or in harmful gases, such as sulfide gas (H2S, SO2), ammonia gas (NH3), nitric acid gas (HNO3), or chlorine gas (Cl2). Doing so may impair functionality, such as with damage due to contacting faults or corrosion. * The switch includes contacts. If the switch is used in an atmosphere with silicon gas, arc energy may cause silicon oxide (SiO2) to accumulate on the contacts and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or other silicon products in the vicinity of the switch, use a contact protection circuit to limit arcing and remove the source of the silicon gas. Mounting Terminal box Terminal box Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electric shock or burning may occur. Selecting Models * Install the switch in a location that is not directly subject to debris and dust from cutting. The actuator and the switch body must be protected from accumulated cutting debris and dirt. Incorrect Correct * Do not use the switch in locations subject to hot water (greater than 60C) or in water vapor. We recommend using Drip-proof Models (protection equivalent to IP62) in locations subject to floating dirt and dust. Other models do not have a protective structure. Wiring For wiring, use a wire size that is appropriate for the applied voltage and the supplied current. When soldering the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than 5 s to solder any part of the Switch. Using the Switch with incomplete soldering may result in errors and heat, which may cause burning. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is used or if any part of the Switch is soldered for 6 s or longer. 22 Z Micro Load Applicable Range The suitable tightening torque for screw terminals is given below. Screw terminals except for those on Split-contact Models (Z-10FYB): 0.78 to 1.18 N*m Screw terminals on Split-contact Models (Z-10FY-B): 0.49 to 1.18 N*m Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the operating range shown here, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% ( 60). The equation, 60 = 0.5x10-6/operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60%. Operation * Make sure that the switching speed and frequency are is within the specified ranges. 1. If the switching speed is extremely slow, the contacts may not be switched smoothly, which may result in a contact failure or contact welding. 2. If the switching speed is extremely fast, switching shock may damage the Switch prematurely. If the switching frequency is too high, the contacts may not be able to keep up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. Always conduct appropriate durability tests under actual conditions before using a Switch. * Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 100% of the rated OT. DC voltage (V) Tightening High-sensitivity Switch (Z-15H)/ Extra-high-sensitivity Switch (Z-15H2) * When using the Switch in a DC circuit, be sure to provide an arc suppressor as well because the small contact gap of the Switch may result in contact troubles. * In an application where a high repeat accuracy is required, limit the current that flows through the Switch to within 0.1 A. Also, use a relay to control a high-capacity load if the Switch is connected to such a load. (In this case, the exciting current of the relay coil is the load of the Switch.) * Do not apply a force of 19.6 N or higher to the pin plunger. * Exercise care that the environment conditions such as temperature and humidity do not change abruptly. 800 mW 0.16 mA 30 26 mA 24 Operating range for micro load models Z-01H Operating range for general load models Z-15H, H2 Z-15G Z-15E Z-10FY Z-15ER 12 Unusable range 5 Panel Mount Switch (Z-15@Q@, Z-01@Q@) * When mounting the panel mount plunger model with screws on a side surface, be careful of the dog angle and operation speed. Excessive dog angle or operation speed may damage the Switch. * When using the panel mount plunger model mounted with screws on a side surface, be careful not to apply a large shock. Applying a shock exceeding 1,000 m/s2 may damage the Switch. * When using the panel mount plunger model mounted with screws on a side surface, remove the hexagonal nuts from the actuator. 5 mW 0 0.1 1 mA 1 100 mA 160 mA 10 100 1,000 Current (mA) Z-01H Minimum applicable load 1 mA at 5 VDC Z-15@, Z-10FY 160 mA at 5 VDC Models with Drip-proof Terminal Cover (Z-@A55-B5V) Wiring * To attach the Protective Cover to the case, hold the cover in almost parallel to the case and then push it to the case. If the cover is pushed diagonally, the rubber packing may slip off, degrading the sealability of the Switch. Terminal with toothed washer Rubber packing * Use round solderless terminals having the 4.3 dia. following dimensions to connect leads to the terminals. Tighten the screws of terminals to 8 a torque of 0.78 to 1.18 N*m. Use the 20 max. terminal shown below. * A cable 8.5 to 10.5 mm in diameter can be applicable to the sealing rubber of the lead outlet of the Switch. A two-core or three-core VCT cable having a cross-sectional area of 1.25 mm2 is especially suitable for this. * Use M4 small screws with spring toothed washer are used as the terminal screws. 23 Z Drip-proof Switch (Z-@55) * The Switch is not perfectly oil-tight; so do not dip it in oil or water. * The rubber boots are made from weather-resistive chloroprene rubber. * Do not use Basic Switches in places with radical changes in temperature. * Rubber boots and rubber caps will tend to harden at lower ambient temperatures. If an Actuator is used in a pressed state for an extended period of time at low temperatures, it may return slowly or it may not return at all. OMRON can provide special Actuators for use at low temperature with rubber boots or rubber caps made of silicon rubber, which has superior resistance to cold. Ask your OMRON representative for details. returns, causing chattering. Use a circuit that compensates for chattering wherever possible. * Do not switch the rod to the fullest extent when the Switch is to break a power circuit because such a practice may cause metal deposition to occur between the mating contacts of the Switch. Other Precautions * Do not apply excessive force with a screwdriver or other tool when attaching or removing the Protective Cover. Doing so may deform the Switch. Screwdriver Split-contact Switch (Z-10F@Y) The applicable current varies depending on how the contacts are used. If the Switch is connected in series, the Switch can endure a current 1.5 to 2 times higher than the current that can be applied in parallel connection. Flexible Rod Switch (Z-15@NJ@55, Drip-proof) * The Drip-proof Terminal Protective Cover can be sued only with Switches with model numbers ending in "-B5V." * Only the Terminal Protective Cover is available for maintenance. * When the rod is fully swung, the Switch may operate when the lever Accessories (Order Separately) Refer to Z/A/X/DZ Common Accessories for details about Terminal Covers, Separators, and Actuators. Drip-proof Terminal Cover (Order Separately) The Drip-proof Terminal Protective Cover is provided for maintenance for Z-@A55-B5V Switches. Ordering Information Name Drip-proof Terminal Protective Cover Dimensions (Unit: mm) Model AP-DV 17.4 13.5 dia. 17 dia. 48.51 -2 11 Mounting bracket 7.5 27.9 17.4 15 0.6 51.6 9 17.4 29.51 24 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.12 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: Z15GW-B