Easy-to-Use Timer with Batch Counting
in 72 x 72 mm DIN Size Unit
TIMERS
Timing functions 9 selectable, including ON-delay, repeat cycle, OFF-delay, and one-shot
Contact type One SPDT relay and two NPN open collector transistor outputs
Terminal form 16 terminal screws on rear of case
Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz and 12 to 24 VDC
Part number H5BR-B-AC100-240 H5BR-B-AC24/DC12-24
ACCESSORIES
Description Part number
Soft cover with two mounting clips for front panel protection Y92A-72F1
Shock prevention terminal cover protects wiring connections Y92A-72T
NEMA 4 waterproof cover Y92A-72N
Multifunction Digital Timer H5BR
Nine field-selectable output
modes accommodate a wide
variety of applications
All parameters set by scroll-
through menus accessed from
the front panel
Field-selectable time ranges from
0.001 second to 9999 hours
High-visibility alphanumeric LCD
display has 12 mm high characters
and built-in backlight
Batch counting function records
the number of completed cycles
Contact and solid-state outputs
available simultaneously
Precision control possible to
0.001 second
Four levels of key protection provided
Selectable elapsed time (UP)
and time remaining (DOWN) display
Ordering Information
H5BR H5BR
2
Part number H5BR-B-AC100-240 H5BR-B-AC24/DC12-24
Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz and 12 to 24 VDC
(permissible ripple: 20% max.)
Operating voltage 85% to 110% of rated voltage
AC Approximately 8 VA at 50 Hz, 240 VAC
DC Approximately 5 W at 24 VDC
Inputs Types available Start, reset, gate, batch count reset, and key protect
Type No-voltage input
ON impedance 1 k max. (Approx. 2 mA when 0)
Residual voltage 2 V max. in ON state
OFF impedance 100 k minimum
Pulse width 1 ms or 20 ms selectable for reset and signal
20 ms for gate and batch count reset
Type No-voltage input
ON impedance 1 k max. (Approx. 2 mA when 0)
Residual voltage 1 V max. in ON state
OFF impedance 100 k minimum
Response time 1 second
Type Time limit SPDT relay output or NPN open collector transistor output
Instantaneous
Relay Max. load 5 A, 250 VAC resistive load (p.f. = 1)
Min. load 10 mA, 5 VDC
Max. load 100 mA, 30 VDC
Residual voltage 2 V max., 1 V typical
Batch output Transistor output (NPN open collector)
Repeat accuracy Power start ±0.01%, ±0.05 second max.
Signal start ±0.005%, ±0.03 second max. (rate for set value)
Setting error
Resetting system Power reset (A, A-1, A-2, B, D and E modes)
External, manual, automatic resets (may be internal depending on A-1, B, B-1, D and E
operation modes)
Resetting time Power reset 0.5 second minimum (A, A-1, A-2, B, D and E modes)
Indicators 4-digit LCD alphanumeric display with backlighting
12 mm (0.47 in) H present value, 8 mm (0.31 in) H set value
Memory function Retains preset values for 10 years at 20° C (68° F)
Materials Plastic case
Mounting Panel
Connections Screw terminals
Weight 270 g (9.6 oz)
Range selection Time unit Maximum setting
- . - - - s 0.001 second 9.999 seconds
- - . - - s 0.01 second 99.99 seconds
- - - . - s 0.1 second 999.9 seconds
- - - - s 1 second 9999 seconds
- - min - - s 1 second 99 minutes 59 seconds
- - - . - min 0.1 minute 999.9 minutes
- - - - min 1 minute 9999 minutes
- - hr - - min 1 minute 99 hours 59 minutes
- - - . - hr 0.1 hour 999.9 hours
- - - - hr 1 hour 9999 hours
Specifications
Control
output
Signal,
reset,
gate,
batch
count
reset
Power
consumption
Key
protect
Solid-
state
H5BR H5BR
*One-shot output can be set from 0.1 to 99.9 s.
RANGE AND OPERATION MODE SELECTION
Mode Operation Output type
A ON-delay Sustained or
A-1 Sustained start signal ON-delay one-shot*
A-2 Power ON-delay
A-3 Power ON-delay/non-power
resettable
B Repeat cycle
B-1 Repeat cycle/non-power
resettable
D OFF-delay Sustained
E One-shot
F Cumulative signal ON-delay
H5BR H5BR
3
Approvals UL/ CSA/SEV/CE (EMC)
Operating ambient temperature -10° to 55°C (14° to 131°F) with no icing
Humidity 35% to 85% RH
Vibration Mechanical durability 10 to 55 Hz with 0.75 mm (0.03 in) single amplitude in 3 directions
Malfunction durability 10 to 55 Hz with 0.5 mm (0.02 in) single amplitude in 3 directions
Shock Mechanical durability 30 G each in three directions
Malfunction durability 10 G each in three directions
Variation due to voltage change Included in "Repeat accuracy" specification
Variation due to temperature change Included in "Repeat accuracy" specification
Insulation resistance 100 M min. at 500 VDC between current-carrying terminal and exposed non-current-
carrying metal parts, and between non-continuous contacts.
Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
non-current-carrying metal parts for 100 to 240 VAC type
1,000 VAC for both 24 VAC and 12 to 24 VDC types
Service life Mechanical 10 million operations minimum
(SPDT relay) Electrical 100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
SPECIFICATIONS continued
Timing Charts
Output mode A: Signal ON delay 1 (Timer resets when power comes on.)
Timing begins at the leading edge of
the start signal. The control output will
be energized when the present value
equals the preset time. The output will
be sustained until a reset signal is
applied, until power is interrupted, or
for a programmable one-shot time
period.
Output mode A1: Signal ON delay 2 (Timer resets when power comes on.)
Timing begins at the leading edge of the
start signal. The control output will be
energized if the start signal is sustained
for an amount of time equal to the preset
time. The output will be sustained until
the start signal is interrupted, until a reset
signal is applied, until power is
interrupted, or for a programmable one-
shot time period.
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Power
Start signal
Set value
UP 0
Gate
Reset
Control output
Set value
DOWN 0
Timing
diagram
Timing
diagram
Sustained output
One-shot One-shot output can be set from 0.1 s to 99.9 s.
OPERATION MODES
H5BR H5BR
4
Output mode A-2: Power ON delay 1 (Timer resets when power comes on.)
Timing begins when power is applied.
Start signals act as a gate input,
causing the present value to hold. The
control output will be energized when
the present value equals the preset
time. The output will be sustained until
a reset signal is applied, until power is
interrupted, or for a programmable
one-shot time period.
Output mode A-3: Power ON delay 2 (Timer does not reset when power comes on.)
Output mode B: Repeat cycle 1 (Timer resets when power comes on.)
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
control output will be OFF for the first
cycle. In subsequent cycles the output
will be ON for the programmable one-
shot time period, then OFF for the
remainder of the preset time. The cycle
will be repeated until a reset input is
applied or power is interrupted.
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
output relay will be OFF for the preset
time, then ON for the preset time. The
cycle will be repeated until a reset input
is applied or power is interrupted.
Timing begins when power is applied.
Start signals act as a gate input, causing
the present value to hold. The control
output will be energized when the
present value equals the preset time.
The output will be sustained until a reset
signal is applied or for a programmable
one-shot time period. If power to the unit
is interrupted, the control output will be
de-energized. The output will re-
energize once power is restored.
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
Sustained output
One-shot One-shot output can be set from 0.1 s to 99.9 s.
a = one-shot time before power interruption
t-a = remaining one-shot time after power interruption
H5BR H5BR
5
Output mode E: Interval (Timer resets when power comes on.)
Timing begins on the leading edge of the
start signal. The control output is only
energized during timing. The timer is
reset when power is interrupted or a
reset signal is applied.
Output mode B-1: Repeat cycle 2 (Timer does not reset when power comes on.) The OFF/ON cycle is initiated at the
leading edge of the start signal. The
output relay will be OFF for the preset
time, then ON for the preset time. The
cycle will be repeated until a reset input
is applied. If power to the unit is
interrupted, the present value will hold.
The cycle will continue from that point
once power is restored.
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
control output will be OFF for the first
cycle. In subsequent cycles the output
will be ON for the programmable one-
shot time period, then OFF for the
remainder of the preset time. The cycle
will be repeated until a reset input is
applied. If power to the unit is
interrupted, the present value will hold.
The cycle will continue from that point
once power is restored.
Output mode D: Signal OFF delay (Timer resets when power comes on.)
The control output is energized at the
leading edge of the start signal. Timing
begins at the trailing edge of the start
signal. The control output is de-
energized when the present value equals
the preset time.
Start signal
Gate
Power
Reset
Control output
Set value
UP 0
DOWN 0
Set value
Timing
diagram
Start signal
Gate
Power
Power
Start signal
Gate
Reset
DOWN 0
Set value
UP 0Timing
diagram
Set value
Control output
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
Sustained output
One-shot One-shot output can be set from 0.1 s to 99.9 s.
a = one-shot time before power interruption
t-a = remaining one-shot time after power interruption
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
H5BR H5BR
6
Timing begins on the leading edge of the
start signal. The control output is
energized when the cumulative elapsed
time of the start signal is equal to the
preset time. The output is sustained until
power is interrupted or a reset signal is
applied.
Output mode F: Cumulative (Timer does not reset when power comes on.)
Power
Start signal
Gate
Reset
Control output
Set value
UP 0
Set value
DOWN 0
Timing
diagram
The batch count output holds until reset
by the batch count reset. The present
value of the batch count advances
continuously.
Batch count reset
Batch count set
value
Batch output
Batch count
present value 0
TIMER
Dimensions
Unit: mm (inch)
1. The batch count present value remains
at 0 while the batch count reset is ON.
2. When the batch count set value is 0,
the batch count will proceed, but there
will be no output.
3. When the batch count present value
exceeds 9999, it returns to 0.
4. The batch count present value and
output are not affected by the RESET
key or reset input.
5. When power is interrupted and the
batch count output is ON, the output
will be ON when power returns.
6. When a batch count set value greater
than the present value is changed to a
set value less than the present value,
the output will go ON.
7. If, after the output has gone ON, the set
value is changed to a set value that is
greater than the present value, the
output will remain ON.
8. When utilizing latching outputs in the
repeat cycle modes (B and B1), the
number of completed timing is double
the number of outputs. To control the
number of outputs, set the batch count
set value at double the desired number
of outputs.
72
(2.83)
72
(2.83)
6
(0.24) 100
(3.94)
67.6
(2.66)
M3.5 terminal screw,
effective length: 6 mm (0.24)
BATCH COUNTER OPERATION
H5BR H5BR
7
PANEL MOUNTING H5BR TIMERS
A pair of panel mounting adapters is included with the timer. The adapters are installed in the slots on the right and left sides of the case,
as shown below.
100
(3.94)
6
(0.24) 7 + panel thickness
100 min.
(3.94)
82 min.
(3.23)
68 +0.7
(2.68)
68 +0.7
(2.68)
-0
-0
ACCESSORIES
Y92A-72F1 Soft plastic cover
Two mounting clips help the soft plastic cover Y92A-72F1 fit
snugly over the front of the timer to protect against dirt and
water. Timer settings can be changed when the cover is on.
The cover is intended for use in areas where unusual service
conditions do not exist.
Y92A-72T Terminal cover
Connections
TERMINAL ARRANGEMENT
H5BR-B
The terminal cover protects wiring connections.
Panel Cutouts
Panel cutouts shown at right
conform to DIN 43700.
Note: Do not connect unused terminals.
BATCH RST
SIGNAL
GATE
KEY/P
SOURCE
TIMED
TIMED
AUX POWER
12 VDC
80 mA max.
0 V
BATCH
100 mA max.
30 VDC
5 A
250 VAC
100 mA max.
30 VDC
RESET
69
(2.72)
69
(2.72)
75.8
(2.98)
75.8
(2.98)
H5BR H5BR
8
INPUTS
The inputs of the H5BR are no-voltage (short circuit or open) inputs.
No-contact Input
(NPN Transistor) Contact Input No-contact Input
Sensor
Timer
Input use 0 V
Timer
Start signal,
reset, etc.
Input use 0 V
(30 V max.)
+ V Sensor
Timer
12 VDC
Start signal,
reset, etc.
Input use 0 V
High: contact ON High: transistor ON
High: transistor ON
Operation
NOMENCLATURE
Signal
input
indicator
Reset
indicator Gate
indicator Key protection
indicator
Power
indicator
Control
output
indicator
Batch output
indicator
Increment
keys (1–4)
Timing
indicator
Present value
Character height: 12 mm (0.47 in)
Nonsignificant zeros suppressed
Elapsed time indicator
Indicates the fraction of the unit that has
elapsed. Displayed for timing ranges of
9999 min. or greater.
Mode
key Batch
key Display
key
Reset
key
Mode
indicator Set value
Character height: 8 mm (0.31 in)
Value in set function mode
PW SG OUT
4
DISPLAY
BATCHMODE
RST GT BATCH
No-voltage Input Signal Levels
Input terminal numbers (no voltage) Power supply terminals Output terminal numbers
Contact Solid-state
Timed Batch
Reset Start Gate COM COM NO NC COM Load COM Load
9 10111516 81 2 3 45671314
1. High level
Transistor ON
No-contact Residual voltage: 2 V max.
input Impedance when ON:
1 k max.
2. Low level
Transistor OFF
Impedance when OFF:
100 k min.
Contact Use contacts which can
input adequately switch 2 mA
at 5 V.
Terminal Numbers on Power Supply
for External Equipment
Voltage supply DC- DC+
12 VDC, 80 mA 8 12
Batch
reset Key
protect
AC
(common),
DC–
AC
(hot),
DC+
321
Start signal,
reset, etc.
H5BR H5BR
9
Model H5BR-B (Standard)
Time range - -.- -s
Present value 0.00 s
Presets 0.00 s
Batch present count 0
Batch preset 0
UP/DOWN mode UP
Output mode A: Signal ON-delay (1)
Output time Hold
Input signal time 20 ms
Key protect level KP-1
Key name Operation
Increment keys (1-4) Used to change the corresponding digit of the set value. Used to change data in the set mode.
Display key Switches to the present value display.
Batch key Switches to the batch display.
Mode key Switches from run mode to set mode. Changes items in the set mode.
Reset key Resets timing and outputs.
KEY OPERATIONS
The following table shows the timer settings when it is shipped. Change the settings as necessary to suit the system before
operation. Settings and the display receive power from the internal battery and are, therefore, unaffected by external power
interruptions. With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs
cannot be used without a power supply.
FACTORY SETTINGS
Inputs Start signal Stops timing in A-2 and A-3 (power ON-delay) modes. Starts timing in other modes.
Reset Resets present value (to zero in UP mode, to preset in DOWN mode).
Control inputs are not accepted while reset input is ON.
Reset indicator lit while reset input is ON.
Gate Inhibits timer operation.
Batch count reset Resets batch count to zero and batch output turns OFF on leading edge.
Batch count signals are not accepted while batch count reset is ON.
Key protect Makes keys inoperative according to key protect level; four levels available.
Key protected indicator lit while key protect input is ON.
Effective when protect terminals are shorted.
Effective if power supply is turned off.
Outputs Control output (OUT) Outputs made according to designated output mode when corresponding preset is reached.
Batch output Outputs made when batch count equals the preset number of batches.
Batch output remains ON until batch count reset goes ON.
When the number of batches is set to zero, batch counting is performed, but batch outputs
are not made.
INPUT/OUTPUT FUNCTIONS
Counting the Number of Bottles Filled
Fill time = 3.5 seconds
Batch preset = 500
BATCH COUNTER APPLICATION
BATCH
DISPLAY
H5BR H5BR
10
Mode Setting item Description Setting procedure
Run mode Set value Compared to the present value. Sequence when changing a digit using the
Determines the timing of the control increment keys (1 to 4).
output according to the output mode.
Batch count set Turns ON the batch output when Sequence when changing a digit using the
value the preset number of cycles have been increment keys (1 to 4).
completed.
Setting mode Time range Determines the timing range. Change the timing range with the increment
keys (1 to 4).
UP/DOWN mode Selects the display that shows elapsed Select UP/DOWN with the increment keys
time (UP) or time remaining (DOWN). (1 to 4).
Output mode Determines the control output type. Sequence when changing the mode using the
(Refer to the
Operation Modes Timing
increment keys (1 to 4).
Charts
on pages 18 to 21.)
Output time Determines the duration of the control Use keys 1 to 3 to change the value.
output. Will be displayed when the Key 1 adjusts the first digit (0.1 digit).
output mode is A, A-1, A-2, A-3, B, Key 2 adjusts the second digit (1 digit).
or B-1. Will not be displayed in Key 3 adjusts the third digit (10 digit).
output modes D, E, or F.
Key 4 selects either hold output or one-shot output.
Input signal time Changes the duration of the control Change the duration with increment keys
and reset input signals. (1 to 4).
Key protect level Locks certain keys to prevent accidental Sequence when changing the key protect
operation. The key protection level, level using the increment keys (1 to 4).
kP-1 to kP-4, determines which keys are
locked when the key protection input
is ON. The locked keys are crossed
out in the diagram at right.
OPERATIONAL OVERVIEW
Refer to the Setting Item Table below for details on the operation of specific modes.
Note: 1. Set values are changed using
the increment keys (1 to 4).
2. The large arrow indicates the
parameter displayed first when the mode
is changed with the MODE or DISPLAY key.
SETTING ITEM TABLE
Note: 1. Changes made in setting mode become effective when run mode is entered.
2. The time range setting appears first when setting mode is entered.
<kP–1> <kP–2>
<kP–3> <kP–4>
Run mode
Press the
MODE key
UP/DOWN mode
Present value,
set value
Setting mode
Key protect
level
Timing range Output mode Output time Input signal time
Press the
MODE key Press the
MODE key Press the
MODE key Press the
MODE key Press the
MODE key
Press the
DISPLAY key
Batch count value,
set value
Press the
BATCH key
Press the
DISPLAY key
H5BR H5BR
11
EXAMPLES
Changing the Set Value
Run Mode
To change the set value from 3 hr 5 min to 4 hr 5 min, press
the 3 key so that the number 4 appears in the hour's place.
Pressing keys 1 through 4 increments the corresponding
column by 1.
The columns can be changed in any order, but the output will
be turned ON if the set value is less than the present value.
Nonsignificant zeros are suppressed on the set value display.
Note: Read
Changing Set Values
in the
Precautions
section
before changing the timer set value during operation.
Changing the Batch Count Set Value
1. Press the BATCH key to switch from the present value
display to the batch count display. 2. Change the set value when the timer is set to the batch
count display.
Nonsignificant zeros are normally suppressed on the batch
count set value display.
Press the DISPLAY key to switch back from the batch
count display to the present value display.
Changing Settings in the Set Mode
1. Press the MODE key to switch from run mode to set mode.
The timer will continue operation according to existing
settings when switched from run mode to set mode during
operation.
The MODE key will be locked if the key protection function
is enabled.
Settings changed in the set mode do not take effect until
run mode is entered. Because the operating conditions will
change once this occurs, always use the RESET key or a
reset input to reset operation.
Setting Mode
2. Press the MODE key to scroll successively through the items
that can be set.
H5BR H5BR
12
3. To change the selected item,
Press the MODE key until the desired item appears. Change the item setting by pressing keys 1 through 4.
(Press the DISPLAY key to switch back from set mode to
run mode.)
Precautions
POWER SUPPLIES
If power is interrupted for less than 10 ms, operation will
continue normally. If power is interrupted for 10 to 500 ms,
operation will be inconsistent, and timing may stop or reset,
depending on the mode.
Connect the power supply voltage through a relay or switch
in such a way that the voltage reaches a fixed value
immediately.
Depending on switching frequency, current surges may
degrade relay contacts; relays with a capacity greater than
10 A are recommended.
EXTERNAL POWER SUPPLY
The capacity of the external power supply is 80 mA at 12
VDC. When using a 24 VAC/12 to 24 VDC power supply,
reduce the load with the power supply voltage, as shown in
the following diagram (DC power supplies only).
Be sure that the capacity of the external power supply is
adequate, because the power supply may not provide a
surge current sufficient to start the timer due to the switching
regulator contained in the timer's internal circuitry.
INPUT AND OUTPUT
Do not use external sources to increase the voltage of input
signals (control signal, reset, gate, and key protection).
Be sure that the load of the control output (contact, transistor)
is less than the maximum values indicated in the
specifications. If the output load exceeds the recommended
value, the life span of the contact output type will be
shortened dramatically, and the transistor of the transistor
output type will be damaged.
The transistor output is opto-isolated from the internal
circuitry, so either NPN or PNP transistors can be used.
SELF-DIAGNOSTIC FUNCTION
The following displays will appear if an error occurs. The
present value and output enter the same status as after
pressing the RESET key.
Display Error Output Correction Set
status
CPU OFF No
change
Memory Set at the
factory
Press
RESET
key
(batch
count to 0)
H5BR H5BR
13
CHANGING SET VALUES
The timer set value can be changed while the timer is
operating, so a high value can be set temporarily to
inactivate the timer, or a low value can be set to activate the
timer more quickly. If the set value is changed accidentally
during operation, the timed output might be activated.
Therefore, turn the key protection input ON unless the set
value is being changed.
To avoid changing the output when changing the set value, it
is recommended to begin changing the set value by entering
a large number in the higher digit.
OPERATING ENVIRONMENT
OTHER
When the timer is installed in a control box and tests are
conducted which may damage the timer's internal circuitry
(for example, a test measuring the maximum voltage
difference between the control circuit and metal
components), remove the timer from the control box or short
circuit the terminals.
CAUTION
This product contains a lithium battery. Lithium batteries
explode if incinerated. Dispose of the digital timer as a non-
combustible item.
When using the timer in an area with much electrical noise,
separate the timer, wiring, and the equipment which
generates the input signals as far as possible from the noise
sources. It is also recommended to shield the input signal
wiring to prevent electrical interference.
Organic solvents (such as paint thinner), as well as very
acidic or basic solutions, might damage the outer casing of
the timer.
OMRON ELECTRONICS LLC OMRON CANADA, INC.
One East Commerce Drive 885 Milner Avenue
Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8
1-800-55-OMRON 416-286-6465
Cat. No. GC TMCN1 3/02 Specifications subject to change without notice. Printed in the U.S.A.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.