GPEU4
Ferrule Fuses
gG 400V to 690V
with/without Striker
gG 8x32, 10x38, 14x51, 22x58
General Purpose Fuses IEC
General Purpose Fuses IEC
P201815
R212075
Size Rated Rated Previous Reference Breaking Catalog
(mm x m m) C ur re nt In Voltage Reference Number Capacity Number
(A)
2 17413 J211033
4 17419 H212067
6 17423 G214113
8 17427 R215134
10 17431 Z216153
12 17433 L217176
14 X 51 16 500V 17435 Z218200 120kA - 500V
20 17437 B219237
25 17439 L222213
32 17443 P200757
40 17447 P201815
50 400V 17451 D211557 120kA - 400V
4 18419 R214628
6 18423 A215648
8 18427 F216665
10 18431 W217691
12 18433 W218726
16 18435 L219775
22 X 58 20 690V 18437 P222975 80kA - 690V
25 18439 M201307
32 18443 S211041
40 18447 R212075
50 18451 M213612
63 18455 S214629
80 18459 F216159
100 500V 18463 T217183 120kA - 500V
125 400V 18465 H218208 120kA - 400V
Ratings – gI-gG with Striker
Fuse Size A B C D E
14 x 51 14.3 51 13.8 7.5 3.8
22 x 58 22.2 58 16.2 7.5 3.8
Dimensions
1 Ceramic body
2 Sand
3 Indicator contact
4 Lower contact
5 Contact ring
6 Melting element
7 Indicator
Striker
BEFORE AFTER
Size Previous Reference Standard Catalog
(mm x mm) Reference Number Pack/CTN Number
10 x 38 19100 R211569
14 x 51 19200 M212600 10
22 x 58 19300 R213616
Packaging 10
Neutral
FR14GG69V2P
FR14GG69V4P
FR14GG69V6P
FR14GG69V8P
FR14GG69V10P
FR14GG69V12P
FR14GG69V16P
FR14GG69V20P
FR14GG69V25P
FR14GG69V32P
FR14GG69V40P
FR14GG69V50P
FR22GG69V4P
FR22GG69V6P
FR22GG69V8P
FR22GG69V10P
FR22GG69V12P
FR22GG69V16P
FR22GG69V20P
FR22GG69V25P
FR22GG69V32P
FR22GG69V40P
FR22GG69V50P
FR22GG69V63P
FR22GG69V80P
FR22GG69V100P
FR22GG69V125P
FRN1038
FRN1451
FRN2258
GPEU5
Ferrule Fuses
gG 400V to 690V
with/without Striker
gG 8x32, 10x38, 14x51, 22x58
General Purpose Fuses IEC
General Purpose Fuses IEC
Characteristics t-l
Cut-off characteristics
PREARCING TIME T(S)
PROSPECTIVE CURRENT (A rms)
PROSPECTIVE CURRENT (kA rms)
MAXIMUM VALUE OF CURRENT (KA PEAK)
GPEU6
General Purpose Fuses IEC
General Purpose Fuses IEC
Characteristics I2t
Table temperature increase (testing in superior contact)
ºC
100
90
80
70
60
50
40
30
20
10
2 4 6 8 10 12 16 20 25 32 2 4 6 8 10 12 16 20 25 32 40 50 16 20 25 32 40 50 63 80 100 125 In
10 x 38 14 x 51 22 x 58
690 V
500 V
400 V
}
{
- OPERATING I2T
- PREARCING I2T
gG
8
6
5
4
3
2
8
6
5
4
3
2
8
6
5
4
3
2
8
6
5
4
3
2
8
6
5
4
3
2
2
Ferrule Fuses
gG 400V to 690V
with/without Striker
gG 8x32, 10x38, 14x51, 22x58
GPEU7
General Purpose Fuses IEC
General Purpose Fuses IEC
Table of maximum length of network in function of In and conductor section.
Maximum standardized power low.
Maximum standardized
power low.
* 99/118:
- 99; Cond. PVC / 118; Cond. PRC
0,5 A
1 A
2 A
4 A
6 A
8 A
10 A
12 A
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A
2 W
2,5 W
0,70 W
0,80 W
0,90 W
1,10 W
1,35 W
1,55 W
1,90 W
2,30 W
2,80 W
3 W
3,4 W
1 W
1,10 W
1,20 W
1,50 W
1,80 W
2,10 W
2,55 W
3 W
3,50 W
3,80 W
4,40 W
4,7 W
1,20 W
1,30 W
1,40 W
1,65 W
2 W
2,40 W
3 W
3,40 W
3,80 W
4,30 W
5,10 W
5,50 W
6,70 W
8 W
9 W
12,5 W
In 10 x 38 14 x 51 22 x 58
Size
IEC 269-2-1
NFC 63.213
UNE 21.103-2-1
10 x 38
25 A
3 W
14 x 51
40 A
5 W
22 x 58
100 A
9,5 W
1,5
2,5
4
6
10
16
25
35
50
16
99/113 20
86/87
134
25
40/59
110/122
183
32
21/29
67/84
139
214
40
13/16
41/51
108/119
165
275
50
7/9
25/33
67/84
139
226
63
13/20
46/58
94/113
172
283
80
8/11
24/32
55/70
130
217
336
100
14/17
33/41
90/108
168
257
367
125
7,3/10
20/27
57/70
128
197
283
379
Copper conductor
section (mm2)Rated Current (In) OF gG Fuses (in A)
gG Class Fuses
Power loss table
Ferrule Fuses
gG 400V to 690V
with/without Striker
gG 8x32, 10x38, 14x51, 22x58