CSM_H3AM_DS_E_3_1
1
Mechatronic Analog Timer
H3AM
Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have any
questions or comments. Refer to Safety Precautions on page 7.
Large Setting Dial and Moving Pointers Ideal
for Easy Operation and Monitoring
Incorporating an easy-to-see large setting dial with moving
pointers.
Wide time-setting range of 0.2 s to 60 h (available through three
time-range model types)
Wide AC power supply range (100 to 240 VAC)
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-1 and IEC60664-1
4 kV for Low Voltage, and EMC Directives.
Conforms to EMC standards.
Six-language instruction manual provided.
Programmable contact enables the building of a self-holding
relay circuit as well as built-in instantaneous contact. (-NS)
Memory retention (-NSR)
Finger protection terminal block
Enables easy sequence checks through instantaneous outputs
for a zero set value at any time range.
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
Model Number Legend
Ordering Information
List of Models
Note: The operation of the instantaneous contacts differs for the self-resetting and electric resetting systems. Refer to Timing Charts on page 5
for details.
H3AM - NS
12
-
3
-
1. Resetting System
None: Self-resetting
R: Electric resetting
3. Accessory
None: Without accessory
300: Waterproof Packing
(Y92S-35) provided
2. Time Range
A: 0.5 s to 30 h
B: 1 s to 60 h
C: 0.2 s to 12 h
Rated supply
voltage
Resetting
system
(See note.)
Control output Time range
0.5 s to 30 h (30 s, 3 min,
30 min, 3 h, 30 h)
1 s to 60 h (60 s, 6 min,
60 min, 6 h, 60 h)
0.2 s to 12 h (12 s, 120 s,
12 min, 120 min, 12 h)
100 to 240
VAC
Self-resetting DPDT contact output
(Time-limit output SPDT and
switchable SPDT
(time-limit instantaneous))
H3AM-NS-A H3AM-NS-B H3AM-NS-C
Electric
resetting
DPDT contact output
(Time-limit output SPDT and
instantaneous output SPDT)
H3AM-NSR-A H3AM-NSR-B H3AM-NSR-C
H3AM
2
Accessory (Order Separately)
Note: Supplied with H3AM-NS@-@-300 models.
Specifications
General
Time Ranges
Note: Instantaneous output is obtained by turning the time setting knob below "0" until the time setting knob stops.
Ratings
Item Model
Waterproof Packing Y92S-35 (See note.)
Operating mode ON-delay
Screw tightening torque 0.98 N·m (10 kgf) max.
Input type Voltage input
Output type Relay: DPDT
Mounting method Flush/Panel mounting, no restriction on mounting angle.
Approved standards UL 508, CSA C22.2 No. 14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1
Model Full scale on
dial
Set time unit
s 10 s min 10 min h (hour) 10 h (hour)
H3AM-@@@-A 3 --- 0.5 to 30 s 0.05 to 3 min 0.5 to 30 min 0.05 to 3 h 0.5 to 30 h
H3AM-@@@-B 6 --- 1 to 60 s 0.1 to 6 min 1 to 60 min 0.1 to 6 h 1 to 60 h
H3AM-@@@-C 12 0.2 to12 s 2 to 120 s 0.2 to 12 min 2 to 120 min 0.2 to 12 h ---
Rated supply voltage 100 to 240 VAC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power reset (-NS) Minimum power-opening time: 0.5 s
Reset input time (-NSR) Minimum input time: 0.5 s
Reset voltage range (-NSR) H level: 85 to 264 VAC
L level: 0 to 10 VAC
Power consumption Approx. 9 VA (Approx. 5 W)
Control output Relays in H3AM-NS (R1) (R2)
Relay in H3AM-NS (R2)
(Contact material: AgSnIn)
Contact output: 5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load: 10 mA at 5 VDC (failure level: P, reference value)
Relay in H3AM-NSR (R1)
(Contact material: AgSnIn)
Contact output: 5 A at 250 VAC, resistive load (cosφ = 1)
The minimum applicable load: 100 mA at 5 VDC (failure level: P, reference value)
Ambient temperature Operating: –10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
H3AM
3
Characteristics
Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.
The H3AM-NS@-@-300 model with waterproof packing is available.
Accuracy of operating
time
±0.7% FS max.
Setting error ±2% FS max.
Reset time Power reset: 0.5 s max.
Reset input time: 0.5 s max.
Influence of voltage ±1% FS max.
Influence of
temperature
±2% FS max.
Insulation resistance 100 M max. (at 500 VDC)
Dielectric strength 2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts
2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals
1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)
1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other
2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles
Impulse withstand
voltage
5 kV between power terminals
5 kV between exposed non-current-carrying metal parts and current-carrying metal parts
Noise immunity ±1.5 kV (between power terminals) square-wave noise by a noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity Malfunction: 8 kV
Destruction: 15 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Shock resistance Destruction: 300 m/s2 3 times each in 6 directions
Malfunction: 150 m/s2 (100 m/s2 in the front/back direction) 3 times each in 6 directions
Life expectancy Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)
Electrical: 100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)
Motor life expectancy 20,000 h
EMC (EMI): EN61812-1
Emission Enclosure: EN55011 class A
Emission AC Mains: EN55011 class A
(EMS): EN61812-1
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Burst: IEC61000-4-4
Immunity Surge: IEC61000-4-5
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Power Frequency Magnetic Fields: IEC61000-4-8
Immunity Voltage Dip/Interruption: IEC61000-4-11
Enclosure rating IP65 (front panel only) (See note.) IP20 (terminal section)
Weight Approx. 350 g
H3AM
4
Nomenclature
Moving Pointer (green):
Displays remaining time.
Power Indicator
(green)
Setting pointer (orange)
Displays set value.
Time setting knob (set time)
Output Indicator (orange)
Time Unit Indicator
Instantaneous or
Time-limit Output Selector for
R2 Relay: (only for H3AM-NS-@
models)
Default setting is time-limit output.
Time Unit Selector
(Illustrated Model: H3AM-@@@-C)
Note: The scale goes up to "3" with the H3AM-@-A and up to "6" with the H3AM-@-B.
Model
Applicable time unit
Full
scale
on
dial
s 10 s min 10 min h 10 h
H3AM-@@@-A
H3AM-@@@-B
H3AM-@@@-C
3
6
12
No
No
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
No
Applicable Time Unit
H3AM
5
Operations
Timing Charts
Power supply (1-2)
Time-limit contact NC (3-4, 7-8) (See note 1.)
Time-limit contact NO (3-5, 6-8) (See note 1.)
Power indicator (POWER)
Output indicator (UP)
Instantaneous contact NC (7-8) (See note 1.)
Instantaneous contact NO (6-8) (See note 1.)
tt
Rt
Note: 1. t is the set time, Rt’ is the reset application time, and t’ is the power interruption time.
2. Reset instantaneous contact is the output contact which turns ON/OFF in synchronization with reset
input.
H3AM-NS
H3AM-NSR
Power supply (1-2)
Time-limit contact NC (3-4)
Time-limit contact NO (3-5)
Reset instantaneous contact NC (7-8) (See note 2.)
Reset instantaneous contact NO (6-8) (See note 2.)
Power indicator (POWER)
Output indicator (UP)
Reset (9-10)
t
t'
t+t'
Rt' Rt'
Note: 1. The R2 contacts (7-8 and 6-8) are programmable and can be set to either instantaneous or time-limit
contacts using the switch located on the bottom of the Timer.
2. Rt is the reset time and t is the set time.
H3AM
6
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3AM (Flush Mounting)
Accessories (Order Separately)
Waterproof Packing
(Provided with H3AM-NS@-@-300 models.)
Installation
Internal Connections and Terminal Arrangement
Note: The R2 relay can be switched between instantaneous and time-limit contacts and thus the contact symbol is shown as follows:
96
33 85
Four, M4x17.5 screw boss
20.1
46 7077.5 dia.
70
70±0.4
17.7 17.5
27.5 dia.
Four, 5-dia. holes
Mounting Holes
70±0.4
96
81-dia. hole
Note: Tightening torque for panel mounting is as follows:
0.3 N·m ±0.05 N·m
Y92S-35
Note: The Y92S-35 is not provided with H3AM. Order separately ,if
water protection is required. Use Waterproof Packing to provide
a level of water protection that complies with IP65 standards.
Depending on the operating environment, the Waterproof
Packing may deteriorate, contract, or harden and so regular
replacement is recommended.
1
2
3
4
5
6
7
8
9
10
R1 R2
Power Supply
(See note)
1
2
3
4
5
6
7
8
9
10
R1 R2
Reset
Power
Supply
Use the same power source for the power supply and
reset input and wire the circuit so that the terminals (1)
and (10) terminals (2) and (9) become the same phase
respectively.
H3AM-NS H3AM-NSR
H3AM
7
Safety Precautions
Precautions for Safe Use
Observe the following items to ensure the safe use of this product.
Environmental Precautions
Store the H3AM within the specified ratings. If the H3AM has been
stored at temperatures –10°C or lower, let it stand for 3 hours or
longer at room temperature before turning ON the power supply.
Use the H3AM within the specified ratings for operating
temperature and humidity.
Do not operate the H3AM in locations subject to sudden or extreme
changes in temperature, or locations where high humidity may
result in condensation.
Do not use the H3AM in locations subject to vibrations or shock.
Extended use in such locations may result in damage due to stress.
Do not use the H3AM in locations subject to excessive dust,
corrosive gas, or direct sunlight.
Install the H3AM well away from any sources of static electricity,
such as pipes transporting molding materials, powders, or liquids.
Do not use organic solvents (such as paint thinner or benzine),
strong alkaline, or strong acids because they will damage the
external finish.
Usage Precautions
Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
Be sure to wire the terminals correctly.
Do not install input lines in the same duct or conduit as power
supply or other high-voltage lines. Doing so may result in
malfunction due to noise. Separate the input lines from high-
voltage lines.
Internal elements may be destroyed if a voltage outside the rated
voltage is applied.
Maintain voltage fluctuations in the power supply within the
specified range.
Use a switch, relay, or other contact so that the rated power supply
voltage will be reached within 0.1 s. If the power supply voltage is
not reached quickly enough, the H3AM may malfunction or outputs
may be unstable.
Precautions for Correct Use
Changing Switch Settings
Be sure to adjust the time unit selector and instantaneous or time-
limit output selector for R2 relay only before the Timer is turned ON,
otherwise the Timer may be damaged or malfunction.
Be sure to set the time only when Timer has stopped, otherwise the
Timer may malfunction.
Setting the Operating Time
Do not turn the time setting knob beyond the permissible range. If a
precise time setting is required, check the operation of the Timer in
trial operation before the Timer is put in actual operation.
Before using the H3AM-NSR, apply voltage between terminals 9 and
10 to reset the operation.
When changing the setting time of the H3AM-NSR to a longer time
value, be sure to apply voltage between terminals 9 and 10 during
the change.
Others
When mounting the Timer on a panel, evenly tighten the Timer to a
specified torque. If the Timer using waterproof packing is tightened to
a torque other than the specified value, required waterproof
properties will not be achieved.
If the Timer is mounted on a control panel, dismount the Timer from
the control panel or short-circuit the circuitry before carrying out a
voltage withstand test between the electric circuitry and non current-
carrying metal part of the machine, in order to prevent the internal
circuitry of the TImer from damage.
The internal elements may be damaged if a voltage other than the
rated supply voltage is applied.
Precautions for EN61812-1
Conformance
The H3AM as a built-in timer conforms to EN61812-1 provided that
the following conditions are satisfied:
The output section of the H3AM is provided only with basic isolation.
The H3AM itself is designed according to the following:
Overvoltage category III
Pollution degree 2
On the above basis:
Operation parts on the front and bottom: Reinforced isolation
With clearance of 5.5 mm and creepage distance of 5.5 mm at 240
VAC
Output: Basic isolation
With clearance of 3.0 mm and creepage distance of 3.0 mm at 240
VAC
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.6
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
H3AM-NS-A-300 AC100-240 H3AM-NS-B AC100-240 H3AM-NS-C AC100-240 H3AM-NSR-A AC100-240 H3AM-
NSR-B AC100-240 H3AM-NSR-C AC100-240 Y92S-35 H3AM-NS-A AC100-240 H3AM-NS-B-300