154N
Constant Voltage
154NCV www.meas-spec.com May 2012
2/4
PERFORMANCE SPECIFICATIONS
Supply Voltage: 10Vdc
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS ≤005PSI ≥015PSI UNITS NOTES
MIN TYP MAX MIN TYP MAX
Span 1psi: 77, 80, 83
5psi: 98, 100, 102 99 100 101 mV
Zero Pressure Output -2.0 0 2.0 -1.0 0 1.0 mV 1
Pressure Non Linearity 1psi: -0.30 to 0.30
5psi: -0.20 to 0.20 -0.10 0.10 %Span 2
Pressure Hysteresis -0.10 ±0.02 0.10 -0.05 ±0.02 0.05 %Span
Repeatability ±0.02 ±0.02 %Span
Input Resistance 5.5 9.0 12.5 5.5 9.0 12.5 KΩ
Output Resistance 4.0 7.0 4.0 6.0 KΩ
Temperature Error – Span -1.0 1.0 -1.0 1.0 %Span 3
Temperature Error – Offset -1.0 1.0 -1.0 1.0 %Span 3
Thermal Hysteresis – Span -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 3
Thermal Hysteresis – Offset -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 3
Long Term Stability – Span ±0.10 ±0.10 %Span/Year
Long Term Stability – Offset ±0.25 ±0.10 %Span/Year
Supply Voltage 10 14 10 14 V 4
Output Load Resistance 5 5 MΩ 5
Insulation Resistance (50Vdc) 50 50 MΩ 6
Output Noise (10Hz to 1KHz) 1.0 1.0 uV p-p
Response Time (10% to 90%) 0.1 0.1 ms
Pressure Overload 1psi: 10X max
5psi: 3X max 3X Rated
Pressure Burst 1psi: 12X max
5psi: 4X max 4X Rated 7
Compensated Temperature 1psi: 0 to 50
5psi: 0 to 70
-20 +85 °C
Operating Temperature -20 +70 -40 +125 ºC 8
Storage Temperature -40 +125 -40 +125 ºC 8
Media – Pressure Port Liquids and Gases compatible with 316/316L Stainless Steel
Media – Reference Port Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber, and 316/316L
Stainless Steel
Notes
1. Measured at vacuum for absolute (A), ambient for gage (G).
2. Best fit straight line.
3. Over the compensated temperature range with respect to 25°C.
4. Guarantees output/input ratiometricity.
5. Load resistance to reduce measurement errors due to output loading.
6. Between case and sensing element.
7. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
8. Maximum temperature range for product with standard cable and connector is -20°C to +105°C.