Amprobe® Test Tools www.Amprobe.com
Data Sheet
Display 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
Polarity Automatic, positive implied, negative polarity indication.
Overrange (OL) or (-OL) is displayed.
Zero Automatic.
Low battery indication The “ “ is displayed when the battery voltage drops below the operating level.
Auto power off Approx. 10 minutes.
Measurement rate 2 times per second, nominal.
Operating Environment 0°C to 50°C / 32°F to 122°F at <70% relative humidity.
Storage Ttemperature -20°C to 60° / -4°F to 140°F, 0 to 80% R.H. with battery removed from meter.
Accuracy Stated accuracy at 74°F ±8°F, <75% relative humidity.
Temperature Coefficient 0.1 × (specified accuracy) per °F, (32°F to 66°F, 82°F to 122°F).
Altitude 6561.7 Feet (2000m).
Jaw opening capability 30mm (1.18 in) conductor.
Power 1.5 volt battery x2, R03/SIZE AAA.
Isolated battery compartment.
Battery life 150 hours typical with carbon-zinc. 300 hours typical with alkaline.
Dimensions 306 × 135 × 30mm (12 × 5.3 × 1.2 in).
Weight Approx. 157g (1.26lb) including battery.
Safety Designed to meet IEC 61010-1 (EN61010-1) and IEC 61010-2-032 (EN61010-2-032), CATIII 600V class II
and pollution degree 2 indoor use comply with CE , UL
ACD-23SW Swivel Clamp Meter
DC Volts
Ranges 400mV, 4V, 40V, 400V, 600V
Resolution 0.1mV
Accuracy ±(0.5% rdg + 2 dgts)
Input Impedance 400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ
Overload Protection 600V DC or AC rms to measure millivolts, use “RANGE “ button to manually select 400mV range.
AC Volts (50Hz - 500Hz)
Ranges 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy ±(1.2% rdg + 5 dgts)
±(2% rdg + 5 dgts) on 600V range
Input Impedance 4V:10MΩ;40V~600V:9.1MΩ
Overload Protection 600V DC or AC rms
AC Current (50Hz - 60Hz)
Ranges 40A , 400A
Resolution 0.01A
Accuracy ±(2.0% rdg + 10 dgts) 50 ~ 60Hz
Overload Protection 400A AC
Electrical Specifications
General Specifications