VIO MAX
at 25°C
PACKAGE
V
LM101A, LM201A, LM301A
HIGH-PERFORMANCE OPERATIONAL AMPLIFIERS
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
2–2
AVAILABLE OPTIONS
PACKAGE
TASMALL OUTLINE CHIP CARRIER CERAMIC DIP PLASTIC DIP FLAT
PACK FLAT PACK
(D) (FK) (JG) (P) (U) (W)
0°C to 70°C7.5 mV LM301AD – – LM301AP – –
–25°C to 85°C2 mV LM201AD – – LM201AP – –
–55°C to 125°C2 mV LM101AD LM101AFK LM101AJG LM101AP LM101AU LM101AW
The D package is available taped and reeled. Add the suffix R to the device type, (i.e., LM301ADR).
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM101A LM201A LM301A UNIT
Supply voltage VCC+ (see Note 1) 22 22 18 V
Supply voltage VCC– (see Note 1) –22 –22 –18 V
Differential input voltage (see Note 2) ±30 ±30 ±30 V
Input voltage (either input, see Notes 1 and 3) ±15 ±15 ±15 V
Voltage between either offset null terminal (N1/N2) and VCC– –0.5 to 2 –0.5 to 2 –0.5 to 2 V
Duration of output short-circuit (see Note 4) unlimited unlimited unlimited
Continuous total power dissipation See Dissipation Rating Table
Operating free-air temperature range –55 to125 –25to85 0to70 °C
Storage temperature range –65 to150 –65 to150 –65 to150 °C
Case temperature for 60 seconds: FK package 260 °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds JG, U, or W package 300 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or P package 260 260 260 °C
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC–.
2. Differential voltages are at the noninverting input terminal with respect to the inverting input terminal.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. The output may be shorted to ground or either power supply. For the LM101A only, the unlimited duration of the short-circuit applies
at (or above) 125°C case temperature or 75°C free-air temperature. For the LM201A only, the unlimited duration of the short-circuit
applies at (or below) 85°C case temperatuare or 75°C free-air temperature.
DISSIPATION RATING TABLE
TA ≤ 25°C DERATING DERATE TA = 70°C TA = 85°C TA = 125°C
POWER RATING FACTOR ABOVE TAPOWER RATING POWER RATING POWER RATING
D500 mW 5.8 mW/°C 64°C 464 mW 377 mW 145 mW
FK 500 mW 11.0 mW/°C 105°C 500 mW 500 mW 275 mW
JG 500 mW 8.4 mW/°C90°C 500 mW 500 mW 210 mW
P 500 mW 8.0 mW/°C87°C 500 mW 500 mW 200 mW
U 500 mW 5.4 mW/°C57°C 432 mW 351 mW 135 mW
W 500 mW 8.0 mW/°C 87°C 500 mW 500 mW 200 mW
recommended operating conditions
MIN MAX UNIT
Supply voltage, VCC+ 518
Supply voltage, VCC– –5–18