SPECIFICATION
DR-75-12 DR-75-24 DR-75-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
12V 24V 48V
6.3A 3.2A 1.6A
0~6.3A 0~3.2A 0~1.6A
76W 76.8W 76.8W
100mVp-p 150mVp-p 240mVp-p
2.0% 1.0% 1.0%
12~14V 24~28V 48~53V
0.5% 0.5% 0.5%
1.0% 1.0% 1.0%
85~264VAC120~370VDC
47~63Hz
76% 80% 81%
1.6A/115V0.96A/230V
COLDSTART 20A/115VAC40A/230VAC
<1mA /240VAC
105~150% ratedoutputpower
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
15~16.5V 29~34V 58~65V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
85 5 (TSW1)detectonheatsinkofpowertransistor
Protectiontype: Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL508, TUVEN60950-1approved
CompliancetoEN55011,EN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2(EN50082-2),heavyindustrylevel,criteria A
-10~+60 (Referto"DeratingCurve")
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes;Mounting:CompliancetoIEC60068-2-6
123.1Khrsmin.MIL-HDBK-217F(25 )
55.5*125.2*100mm(W*H*D)
0.6Kg;20pcs/13Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:DR-75-SPEC2011-06-17
1000ms,60ms/230VAC1800ms,60ms/115VAC atfullload
60ms/230VAC12ms/115VAC atfullload
75WSingleOutputIndustrialDINRailPowerSupply DR-75 series
Universal AC input / Full range
Protections:Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fix switching frequency at 50KHz
3 years warranty
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note4)
EMCIMMUNITY
EMCEMISSION
-10 0 10 20 30 45 50 60
20
40
60
80
100
12V
24V,48V
85 90 105 125 145 165 185 205 225 264245
100
90
80
70
60
50
40
MechanicalSpecification
OutputDerating OutputDeratingVsInputVoltage
CaseNo.923Unit:mm
AMBIENTTEMPERATURE( ) INPUTVOLTAGE(V)60Hz
LOAD(%)
(VERTICAL)
BlockDiagram fosc:50KHz
O.V.P.
CONTROL
FG
I/P -V
+V
RECTIFIERS
&
FILTER
SWITCHING
POWER
FILTER
&
RECTIFIERS
FILTER
EMI
O.L.P.
DETECTION
CIRCUIT
PWM
O.T.P.
TerminalPinNo. Assignment(TB1)
TerminalPinNo. Assignment(TB2)
PinNo.
PinNo.
1
1,2
2
3,4
3
Assignment
Assignment
FG
AC/L(DC-)
AC/N(DC+)
DCOUTPUT +V
DCOUTPUT -V
ADMISSIBLEDIN-RAIL:TS35/7.5OR TS35/15
1
3
2
TB1 TB2
LED
2
4
3
1
+V ADJ.
125.2
55.5
100
35
FileName:DR-75-SPEC2011-06-17
75WSingleOutputIndustrialDINRailPowerSupply DR-75 series
LOAD(%)