54
Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc.
2311 Statham Parkway, Oxnard, CA 93033 • 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com/
FEATURES
• World-wide AC input ranges and safety standards
• Industry standard packages
• UL/CSA TUV/IEC approved—68 models toUL1950; CSA
C22.2 No. 234 L3; TUV certified to IEC950
• Burn-in with cycling; 3-year warranty
• Capacitors have highest CV & ripple current ratings
SPECIFICATIONS
AC Input
100, 120 and 240Vac: +10%, -13%; 215Vac: +12%, -11 %; 47 to 63Hz.
Tolerance for 230Vac operation is +15%,
-10%. Derate output current 10% for 50Hz operation.
DC Output
See voltage rating chart. Adjustment range ±5% minimum except HA
series.
Line Regulation
±0.05% for a 10% change.
Load Regulation
± 0.05% for a 50% load change.
Output Ripple
3mV +0.05% of output voltage, peak to peak maximum. All “3-terminal
regulator” outputs: 3mV +0.2% peak to peak maximum.
Transient Response
<50 microseconds for 50% load change.
Short Circuit Protection
Automatic current limit/foldback.
Overvoltage Protection
INTERNATIONAL+ LINEARS
Built-in on all 5V models, set at 6.2V ±0.4V. Other models use optional
overvoltage protection.
Remote Sensing
Provided on all models; open sense lead protection built-in (except HA
series).
Stability
±0.05% for 24 hours after warmup.
Temperature Rating
0 to 50°C full rated, derated linearly to 40% at 70°C.
Temperature Coefficient
±0.01%/°C maximum.
Efficiency
5V units: 45%; 12 and 15V units: 55%; 20 and 24V units: 60%.
Logic Inhibit and Current-Share
F & G models.
• MTBF 200,000+ hours per Mil Handbk 217D (most units)
• All electrolytic caps rated at 105ºC
• Transformer insulation meets Class F (155ºC)
• Exceed FCC and CISPR22 Class B conducted emissions
•marked to LVD
INTERNATIONAL+ LINEARS