SPECIFICATION
GST280A ser ie s
ORDER NO.
DC VOLTAGE Note.2
SAFETY MODEL NO.
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST280A15
GST280A15-C6P
GST280A12
GST280A12-C6P
GST280A20
GST280A20-C6P
GST280A24
GST280A24-C6P
GST280A48
GST280A48-C6P
15V12V 20V 24V 48V
120mVp-p120mVp-p 150mVp-p 200mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95 / 230VAC PF>0.98 / 115VAC at full load
90%
89.5% 92% 93% 94%
3A / 115VAC 1.5A / 230VAC
1.5mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC I/P-F/G: 2KVAC O/P-F/G: SHORT
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
181.24Khrs min. MIL-HDBK-217F(25℃)
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03% / ℃ (0~40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
220*95*46mm (L*W*H)
1.25Kg; 12pcs/16Kg/1.09CUFT
CONNECTOR
PLUG
CABLE See page 4 ; Other type available by customer requested
See page 4 ; Other type available by customer requested
℃
For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
https://www.meanwell.com/serviceDisclaimer.aspx※:
OVERLOAD
OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
17A21A 13A 11.67A 5.84A
0 ~ 17A0 ~ 21A 0 ~ 13A 0 ~ 11.67A
0 ~ 5.84A
255W252W 260W 280.08W 280.32W
Protection type : Shut down o/p voltage, re-power on to recover
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load
16ms / 230VAC 16ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
280W AC-DC High Reliability Industrial Adaptor
UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1,AS/NZS 60950.1,
BIS IS13252, KC K60950-1, approved EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
File Name:GST280A-SPEC 2020-10-20
Cold start 95A / 115VAC 120A / 230VAC