ø22mm
Dual Pushbutton Switches
HW Series
2
HW Series Dual Pushbutton Switches
Two pushbuttons and a pilot light are integrated into one space-saving ø22 mm control unit.
Momentary and interlock types are available for pushbuttons.
Interlock type prevents both buttons from being pressed at the
same time.
Pilot lights are available in full voltage and transformer types
illuminated with LED or incandescent lamps.
HW-G contact blocks feature spring-up screw terminals to
ensure safety and save wiring time.
UL, CSA approved, and EN compliant
Contact Ratings
Characteristics
Contact Ratings by Utilization Category
Note: The operational current represents the classification by making and breaking currents (IEC 60947-5-1).
Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
Specifications
Safety Standards Mark File No. or Organization
UL508 UL Listing
File No. E68961
CSA C22.2 No. 14 166730 (LR92374)
EN60947-1
EN60947-5-1
TÜV Rheinland R50054316
European Low Voltage Directives
Specifications and Ratings
Contact Block Type HW-G (HW series)
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Operational Voltage 24V 48V 50V 110V 220V 440V
Operational
Current
AC
50/60 Hz AC-12 Control of resistive loads and solid state loads 10A 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72 VA) 10A 7A 5A 3A 1A
DC DC-12 Control of resistive loads and solid state loads 8A 4A 2.2A 1.1A
DC-13 Control of electromagnets 4A 2A 1.1A 0.6A
Operating Temperature –25 to +60°C (no freezing) (LED illuminated type: –25 to +55°C)
Storage Temperature –40 to +80°C
Operating Humidity 45 to 85% RH (no condensation)
Contact Resistance 50 m maximum (initial value)
Insulation Resistance 100 M minimum (500V DC megger)
Dielectric Strength Without pilot light: 2,500V AC, 1 minute (between live and dead metal parts)
With pilot light
Full voltage type: 1,000V AC, 1 minute (between live and dead metal parts)
Transformer and DC-DC converter types: 2,000V AC, 1 minute (between live and dead metal parts)
Shock Resistance Damage limits: 1,000 m/s2
Operating extremes: 100 m/s2
Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Mechanical Life 500,000 operations minimum
Electrical Life 500,000 operations minimum
Degree of Protection IP40 (IP65 when using HW9Z-D7D rubber boot)
Applications:
Ideal for use as power switches and start/stop switches
(av ailable with I/ON and O/OFF markings on the buttons and
a pilot light in the center).
Interlock type pre vents two pushbuttons from being pressed
at the same time, providing the best solution for up/down
switches.
LED Lamp Ratings (LSTD Type)
Note: Specify a color code in place of in the Type No.
Incandescent Lamp Ratings (LS Type)
Rated V oltage T ype No. Operating V oltage
6V AC/DC LSTD-66V AC/DC ±10%
12V AC/DC LSTD-112V AC/DC ±10%
24V AC/DC LSTD-224V AC/DC ±10%
Rated V oltage T ype No. Operating V oltage Lamp Ratings
6V AC/DC LS-6 6V AC/DC ±10% 1W (6.3V)
12V AC/DC LS-8 12V AC/DC ±10% 1W (18V)
24V AC/DC LS-3 24V AC/DC ±10% 1W (30V)
ø22
HW Series Dual Pushbutton Switches
3
ø22
Dimensions
Mounting Hole Layout
0.5
Without Button
Markings With Button Markings
(I/ON and O/OFF)
Panel Thickness 0.8 to 6
14.5
20
49.4 (2 contacts)
69.4 (3 or 4 contacts)
54.8
29.8
54.8
29.8
41.4
Rubber Gasket
Locking Ring
Safety Lever Lock
HW
ON
OFF
Without Pilot Light
Ful Voltage Adapter
69.4 (2 contacts), 89.4 (4 contacts)
(Note)
HW
Wi
th
Pil
ot
Li
ght
Full Voltage
Note:The depth of 3-contact type depends on the
combination of contact bloc ks at top and bottom
pushbutons.
Top Button 1 contact block 2 contact blocks
Bottom Button 2 contact blocks 1 contact block
Depth 89.4 mm 69.4 mm
(Bottom Button)
(Top Button)
79.5 (2 contacts), 99.5 (4 contacts)
Transformer
HW
T
rans
f
ormer
(
240
V
max
i
mum
)
T
rans
f
ormer
(
380
V
m
i
n
i
mum
)
DC-DC Converter
89.5 (2 contacts), 109.5 (4 contacts)
Transformer, DC-DC Converter
HW
R0.8 max.
0
+0.4
+0.4
0
30
55 ∗∗
ø22.3
+0.2
0
3.2
24.1
The 3.2 mm recess is for preventing rotation and is not necessary
when a nameplate or anti-rotation ring is not used.
∗∗ When using the safety lever lock, determine the vertical spacing in
consideration of convenience for installing and removing the safety
lever lock.
Recommended vertical spacing: 100 mm
The minimum mounting centers are applicable to switches with one
layer of contact blocks (two contact blocks). When two layers of con-
tact bloc ks are mounted, determine the minimum mounting centers in
consideration of convenience for wiring.
All dimensions in mm.
HW Series Dual Pushbutton Switches
4
ø22
The Type No. development charts shown below can be used to specify control units other than those listed on the following
pages. Gold-plated silver contacts are also available.
Types
Without Pilot Light
Ordering Information
Operation
Type Button Style Contact Arrangement Type No. Button
Color Code Legend Code
Top
Button Bottom
Button
Momentary
Flush (top)
Flush (bottom) 1NO 1NC HW7D-B111001➃➄
GR:
Green (top)
Red (bottom)
WB:
White (top)
Black (bottom)
Blank:Without legend
1: I/ON (top)
O/OFF (bottom)
1NO 1NO HW7D-B111010➃➄
1NO-1NC 1NO-1NC HW7D-B111111➃➄
2NO 2NC HW7D-B112002➃➄
2NO 2NO HW7D-B112020➃➄
Flush (top)
Extended (bottom) 1NO 1NC HW7D-B121001➃➄
1NO 1NO HW7D-B121010➃➄
1NO-1NC 1NO-1NC HW7D-B121111➃➄
2NO 2NC HW7D-B122002➃➄
2NO 2NO HW7D-B122020➃➄
Interlock
Flush (top)
Flush (bottom) 1NO 1NC HW7D-B211001➃➄
1NO 1NO HW7D-B211010➃➄
1NO-1NC 1NO-1NC HW7D-B211111➃➄
2NO 2NC HW7D-B212002➃➄
2NO 2NO HW7D-B212020➃➄
Flush (top)
Extended (bottom) 1NO 1NC HW7D-B221001➃➄
1NO 1NO HW7D-B221010➃➄
1NO-1NC 1NO-1NC HW7D-B221111➃➄
2NO 2NC HW7D-B222002➃➄
2NO 2NO HW7D-B222020➃➄
HW7D-L 1 1 11 20 H 2 R - GR 1 - MAU
Optional contact
MAU: Gold-plated silver contact
Button legends
Blank: Without legend
1: I/ON + O/OFF
Button color code
GR: Green (top)
Red (bottom)
WB: White (top)
Black (bottom)
Lamp color code
A: Amber (LED only)
G: Green (LED only)
R: Red (LED only)
S: Blue (LED only)
W: White (LED/incandescent)
Y: Yellow (LED only)
Lamp code
0: Without lamp
2: LED (6V: LSTD-6)
3: LED (12V: LSTD-1)
4: LED (24V: LSTD-2)
5: Incandescent (6V: LS-6)
6: Incandescent (12V: LS-8)
7: Incandescent (24V: LS-3)
Operating type
1: Momentary
2: Interlock
Button style
1: Flush + Flush
2: Flush + Extended
Contact arrangement
code (top button)
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
02: 2NC
Contact arrangement code
(bottom button)
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
02: 2NC
Operating voltage code
Q: Full voltage
H: Transformer (100/110V AC)
H2: Transformer (115/120V AC)
M: Transformer (200/220V AC)
M4: Transformer (230/240V AC)
S: Transformer (380V AC)
T: Transformer (400/440V AC)
T8: Transformer (480V AC)
D: DC-DC converter (110V DC)
Notes:
Full voltage type is not supplied with a lamp.
Transformer and DC-DC converter types contain an LED lamp (LSTD-6) or incandescent lamp (LS-6).
Transformer and DC-DC converter types can have two or four contact blocks only.
Dual Pushbutton Switches without Pilot Light Dual Pushbutton Switches with Pilot Light
HW7D-B 1 1 10 02 GR 1 - MAU
Optional contact
MAU: Gold-plated silver
contact
Button legends
Blank: Without legend
1: I/ON + O/OFF
Button color code
GR: Green (top)
Red (bottom)
WB: White (top)
Black (bottom)
Contact arrangement code
(bottom button)
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
02: 2NC
Contact arrangement code
(top button)
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
02: 2NC
Button style
1: Flush + Flush
2: Flush + Extended
Operating type
1: Momentary
2: Interlock
HW Series Dual Pushbutton Switches
5
ø22
With Pilot Light
Designation Codes
Specify designation codes to in the Type No.
Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 9.
LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6, rated voltage 6V AC/DC).
Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
Operation Type Lamp Input Type Contact Arrangement Type No.
Top Button Bottom Button
Momentary
Without Lamp Full Voltage
1NO 1NC HW7D-L11001Q0W➃➄
1NO 1NO HW7D-L11010Q0W➃➄
1NO-1NC 1NO-1NC HW7D-L11111Q0W➃➄
2NO 2NC HW7D-L12002Q0W➃➄
2NO 2NO HW7D-L12020Q0W➃➄
LED
Transformer
1NO 1NC HW7D-L110012➂➃➄
1NO 1NO HW7D-L110102➂➃➄
1NO-1NC 1NO-1NC HW7D-L111112➂➃➄
2NO 2NC HW7D-L120022➂➃➄
2NO 2NO HW7D-L120202➂➃➄
DC-DC Converter
1NO 1NC HW7D-L11001D2➂➃➄
1NO 1NO HW7D-L11010D2➂➃➄
1NO-1NC 1NO-1NC HW7D-L11111D2➂➃➄
2NO 2NC HW7D-L12002D2➂➃➄
2NO 2NO HW7D-L12020D2➂➃➄
Incandescent Transformer
1NO 1NC HW7D-L110015W➃➄
1NO 1NO HW7D-L110105W➃➄
1NO-1NC 1NO-1NC HW7D-L111115W➃➄
2NO 2NC HW7D-L120025W➃➄
2NO 2NO HW7D-L120205W➃➄
Interlock
Without Lamp Full Voltage
1NO 1NC HW7D-L21001Q0W➃➄
1NO 1NO HW7D-L21010Q0W➃➄
1NO-1NC 1NO-1NC HW7D-L21111Q0W➃➄
2NO 2NC HW7D-L22002Q0W➃➄
2NO 2NO HW7D-L22020Q0W➃➄
LED
Transformer
1NO 1NC HW7D-L210012➂➃➄
1NO 1NO HW7D-L210102➂➃➄
1NO-1NC 1NO-1NC HW7D-L211112➂➃➄
2NO 2NC HW7D-L220022➂➃➄
2NO 2NO HW7D-L220202➂➃➄
DC-DC Converter
1NO 1NC HW7D-L21001D2➂➃➄
1NO 1NO HW7D-L21010D2➂➃➄
1NO-1NC 1NO-1NC HW7D-L21111D2➂➃➄
2NO 2NC HW7D-L22002D2➂➃➄
2NO 2NO HW7D-L22020D2➂➃➄
Incandescent Transformer
1NO 1NC HW7D-L210015W➃➄
1NO 1NO HW7D-L210105W➃➄
1NO-1NC 1NO-1NC HW7D-L211115W➃➄
2NO 2NC HW7D-L220025W➃➄
2NO 2NO HW7D-L220205W➃➄
Button Style Code Operating V oltage Code Lamp Color Code Button Color
Code Legend Code
H: 100/110V AC
H2: 115/120V AC
M: 200/220V AC
M4: 230/240V AC
S: 380V AC
T: 400/440V AC
T8: 480V AC
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
The lens is white only.
GR: Green (top)
Red (bottom)
WB:White (top)
Black (bottom)
Blank: Without legend
1: I/ON (top)
O/OFF (bottom)
1: Flush (top)
Flush (bottom)
2: Flush (top)
Extended (bottom)
HW Series Dual Pushbutton Switches
6
ø22
Contact Arrangement Chart
Transformer and DC-DC converter types can have two or four contact blocks only.
Contact blocks 1 and 3 are actuated by the top button. Contact blocks 2 and 4 are actuated by the bottom button.
Contact Block Mounting Position and Contact Arrangement Chart
Contact Arrangement Contact Block Top Button Bottom Button
Top Button Bottom Button Contact Code Mounting Position Type Normal Push Normal Push
1NO 1NO 1010 1NO
2NO
1NO 1NC 1001 1NO
2NC
1NC 1NO 0110 1NC
2NO
1NC 1NC 0101 1NC
2NC
1NO 2NO 1020
1NO
2NO
3Dummy
4NO
1NO 1NO-1NC 1011
1NO
2NO
3Dummy
4NC
1NO 2NC 1002
1NO
2NC
3Dummy
4NC
1NC 2NO 0120
1NC
2NO
3Dummy
4NO
1NC 1NO-1NC 0111
1NC
2NO
3Dummy
4NC
1NC 2NC 0102
1NC
2NC
3Dummy
4NC
2NO 1NO 2010
1NO
2NO
3NO
4Dummy
2NO 1NC 2001
1NO
2NC
3NO
4Dummy
1NO-1NC 1NO 1110
1NO
2NO
3NC
4Dummy
1NO-1NC 1NC 1101
1NO
2NO
3NC
4Dummy
1
3
2
4
1
3
2
4Full V oltage Contact Block Top Button Bottom Button
Normal Push Normal Push
1NO
2NO
3NC
4NC
Type No. Development
HW7D - B 12 11 11 GR Contact code (1NO-1NC) of bottom button
Contact code (1NO-1NC) of top button
Without Pilot Light
With Pilot Light
(transformer type)
With Pilot Light
(full voltage type)
Adapter
HW Series Dual Pushbutton Switches
7
ø22
Contact Arrangement Chart
Contact Arrangement Contact Block Top Button Bottom Button
Top Button Bottom Button Contact Code Mounting Position Type Normal Push Normal Push
2NC 1NO 0210
1NC
2NO
3NC
4Dummy
2NC 1NC 0201
1NC
2NC
3NC
4Dummy
2NO 2NO 2020
1NO
2NO
3NO
4NO
2NO 1NO-1NC 2011
1NO
2NO
3NO
4NC
2NO 2NC 2002
1NO
2NC
3NO
4NC
1NO-1NC 2NO 1120
1NO
2NO
3NC
4NO
1NO-1NC 1NO-1NC 1111
1NO
2NO
3NC
4NC
1NO-1NC 2NC 1102
1NO
2NC
3NC
4NC
2NC 2NO 0220
1NC
2NO
3NC
4NO
2NC 1NO-1NC 0211
1NC
2NO
3NC
4NC
2NC 2NC 0202
1NC
2NC
3NC
4NC
HW Series Accessories and Replacement Parts
8
ø22
Accessories
Shape Material Type No. Ordering
Type No. Package
Quantity Dimensions (mm)
Rubber Boot
Clear Silicon
Rubber HW9Z-D7D HW9Z-D7D 1
Degree of protection: IP65
Locking Ring Wrench
Metal
(weight:
approx. 150g) MW9Z-T1 MW9Z-T1 1
Used to tighten the locking ring when installing the
HW switch onto a panel.
Tighten the locking ring to a torque of 2.0 N·m.
Lamp Holder Tool
Rubber OR-55 OR-55 1
Used to install and remove the LED/incandescent
lamps.
Rubber Mounting
Hole Plug
Rubber (black) OB-31 OB-31PN05 5
Used to plug unused ø22.2mm mounting holes.
Metallic Mounting
Hole Plug
Diecast Metal
(locking ring:
plastic) LW9Z-BM LW9Z-BM 1
Used to plug unused ø22.2mm mounting holes.
Tighten the locking ring to a torque of 1.2 N·m.
IP66 (when the mounting hole does not hav e a ø3.2
mm hole for anti-rotation)
Mounting panel thickness: 0.8 to 6 mm
Barrier
Plastic HW-VG1 HW-VG1PN10 10
Used to prevent contact between adjacent lead
wires when units are mounted closely. Barriers
should always be used in close mounting.
Ring Adapter
Rubber HW9Z-A25 HW9Z-A25PN05 5 Used to install the HW/TW units into ø25mm
mounting holes.
Cannot be used with the HW9Z-D7D rubber boot.
Safety Lever Lock
Plastic HW9Z-LS HW9Z-LSPN10 10 Yellow
33
58
22.5
ø28
110
59
ø11.6
ø14
ø25
ø29
3.5
3.5
Gasket
Locking Ring
ø25.8
12 3
20 1.5
45
HW Series Accessories and Replacement Parts
9
ø22
LED Lamps (LSTD Type)
Incandescent Lamps (LS Type)
Transformer
Maintenance Parts
Operating V oltage Rated Current Type No. Ordering
Type No. Illumination
Color Code Package
Quantity Base
AC DC
6V AC/DC ±10% 17 mA (A, R, W, Y)
8 mA (G, S) 14 mA (A, R, W, Y)
5.5 mA (G, S) LSTD-6LSTD-6
Specify a color code
in place of in the
Ordering Type No .
A: amber
G: green
R: red
S: blue
W: white
Y: yellow
1
BA9S/13
LSTD-6PN10 10
12V AC/DC ±10%
11 mA 10 mA LSTD-1LSTD-11
LSTD-1PN10 10
24V AC/DC ±10%
11 mA 10 mA LSTD-2LSTD-21
LSTD-2PN10 10
Rated Operating
Voltage Lamp Ratings Type No. Package
Quantity
6V AC/DC
1W (6.3V) LS-6
1
12V AC/DC
1W (18V) LS-8
24V AC/DC
1W (30V) LS-3
Shape Primary V oltage Secondary
Voltage Type No. Applicable Load
Separate Mounting Type 100/110V AC
5.5V
TWR516 One full voltage type containing LSTD-6 LED
lamp (6V AC/DC) or LS-6 incandescent lamp
(6.3V AC/DC, 1W).
200/220V AC TWR526
400/440V AC TWR546
HW Series Instructions
10
ø22
Turn off power to HW series control units before starting
installation, removal, wiring, maintenance, and inspection
of the products. Failure to turn power off may cause electri-
cal shocks or fire hazard.
To avoid the possibility of burning yourself, use the lamp
holder tool when replacing lamps.
For wiring, use wires of a proper size to meet voltage and
current requirements. Tighten the M3.5 terminal screws to
a tightening torque of 1.0 to 1.3 N·m. Failure to tighten ter-
minal screws may cause overheating and fire.
Panel Mounting
Remove the contact block assembly from the operator (for
transformer type pilot lights, remove the transformer from
the illumination unit). Remove the locking ring from the oper-
ator. Insert the operator into the panel cut-out from the front,
tighten the locking ring from the back, then install the con-
tact block assembly to the operator.
Removing and Installing the Contact Block Assembly
1. To remove the operator from the contact block, turn the
locking lever in the direction of the arrow shown below.
The operator can now be removed.
2. To reinstall, place the TOP markings on the operator and
the contact bloc k mounting adapter in the same direction,
and insert the operator into the contact block mounting
adapter. Then turn the locking lever in the opposite direc-
tion.
Notes for Panel Mounting
1. When mounting the operator onto a panel, use the
optional locking ring wrench (MW9Z-T1) to tighten the
locking ring. Tightening torque must not exceed 2.0 N·m.
Do not use pliers. Excessive tightening will damage the
locking ring.
2. F or the contact blocks and transf ormers housing LED and
incandescent lamps, make sure not to press the lamps
too hard, otherwise the lamp socket may be damaged.
Safety Lever Lock
IDEC strongly recommends using the safety lever lock
(HW9Z-LS, yellow) to prevent heavy vibration or mainte-
nance personnel from unlocking the contact assembly.
1. HW series can be mounted vertically with a minimum
spacing of 55 mm but spacing should be determined to
ensure easy operation (recommended minimum spacing:
100 mm).
2. Mount the control unit onto the panel, lock the lever, and
push in the safety lever lock to install.
3. When the spacing is narrower than the recommended
value , with the le v er unlock ed, mount the saf ety le ver loc k
and insert the contact unit to the operator. Then, lock the
lever and strongly push in the safety lever lock to install.
4. To remove the safety lever lock, insert a flat screwdriver
into the safety lever and push upwards.
Replacement of Lens
Removing
Remov e the lens b y inserting a screwdriver into the recess
of the lens through the bezel.
Installing
Install the lens in the recess between the b uttons by press-
ing against the bezel.
Safety Precautions
Instructions
Push
Lock
Install
Lock Lever
Safety Lever Lock
Contact Block
Operator
Remove
Screwdriver
Safety Lever Lock
Panel
Removing and Installing the Safety Lever Lock
Removing Installing
HW Series Instructions
11
ø22
Replacement of Lamps
Lamps can be replaced by using the lamp holder tool (OR-
55) from the front of the panel, or by removing the contact
block assembly from the operator unit.
Removing the Lamps from the Front of the Panel
[How to Remove]
[How to Install]
1. To install, insert the lamp head into the lamp holder tool,
and hold the lamp as shown in the figure below.
About Pushbutton Switches
Narrow Mounting
When mounting the units closely in a horizontal row on
30mm centers, use optional barriers to prevent interconnec-
tion between adjoining terminals. The barriers can be
attached simply by pressing them onto the sides of contact
blocks.
Tightening T orque for Terminal Screws
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3
N·m.
Installation of LED Illuminated Units
When using full voltage type LED illuminated units, provide
protection against electrical noise, if necessary.
Applicable Wiring
The applicable wire siz e is 2 mm2 maximum. (solid wire ø1.6
mm maximum) One or two wires can be connected.
Applicable Crimping Terminal
Be sure to use an insulation tube or cover on the crimping
part of the crimping terminal to prevent electrical shocks.
Solid Wire
Note: When connecting wires to contact blocks or transformers in
the direction shown below, keep the insulation stripping
length 6.6 mm at the maximum.
Installing the Rubber Boot
When using the HW7D pushbuttons in places where the
pushbuttons are subjected to water splash or an excessive
amount of dust, make sure to use the HW9Z-D7D rubber
boot (IP65) which is ordered separately.
Notes for Installing the Rubber Boot
Remove the gasket from the operator, and install the rubber
boot on the operator. Pull out the seals of the rubber boot
and place them around the operator slee ve as shown. Make
sure that the seals are not twisted or tucked inside and that
the gasket does not remain, otherwise the normal water-
proof and dustproof characteristics are not ensured.
Instructions
1. To remove, slip the lamp
holder tool onto the lamp
head lightly. Then push
slightly, and turn the lamp
holder tool counterclock-
wise.
Lamp Lamp Holder Tool
Lam
p
Base
2. Place the pins on the lamp
base to the grooves in the
lamp socket. Insert the
lamp and turn it clockwise.
P
u
shb
utt
o
n
s
Do not attempt
to remove the
pushbuttons!
The pushbuttons cannot
be removed or replaced!
Do not attempt to remove
using a flat screwdriver or
pincers, otherwise the
pushbuttons may be dam-
aged.
Barrier
30 30
X2X1 X2X1
Inside Inside
When mounting transformer
type illuminated units closely
in a horizontal row on 30-mm
centers, insert solid wires or
stranded wires into inside of
the terminal screw on the
transformer (see figure on the
right) to prevent short circuit
between adjoining terminals.
ø3.6 min.
7.9 max.
4 max. 5.5 min.
8 max.
ø1.6 max.
X2X1
Remove
Gasket
Install
Remove the gasket. Rubber boot is
installed.
Install the rubber boot
on the pushbuttons.
Seals
Seals
IDEC CORPORATION (USA)
1175 Elko Drive, Sunnyvale, CA 94089-2209, USA
Tel: +1-408-747-0550, Toll Free: (800) 262-IDEC, Fax: +1-408-744-9055
E-mail: opencontact@idec.com, www.idec.com
IDEC CANADA LIMITED
Unit 22-151, Brunel Road Mississauga, Ontario, L4Z 1X3, Canada
Tel: +1-905-890-8561, Toll Free: (888) 317-4332, Fax: +1-905-890-8562
IDEC ELECTRONICS LIMITED
Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire
RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: idec@uk.idec.com
IDEC ELEKTROTECHNIK GmbH
Wendenstrasse 331, D-20537 Hamburg, Germany
Tel: +49-40-25 30 54 10, Fax: +49-40-25 30 54 24
E-mail: service@idec.de, www.idec.de
IDEC AUSTRALIA PTY. LTD.
2/3 Macro Court, Rowville, Victoria 3178, Australia
Toll Free: 1-800-68-4332, Fax: +61-3-9763-3255
E-mail: sales@au.idec.com
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
www.idec.com
Specifications and other descriptions in this catalog are subject to change without notice.
Cat. No. EP1075-0 APRIL 2005 DNP PRINTED IN JAPAN
IDEC IZUMI ASIA PTE. LTD.
No. 31, Tannery Lane #05-01, Dragon Land Building, Singapore 347788
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: generalinfo@idecasia.com.sg
IDEC IZUMI (H.K.) CO., LTD.
Unit 1505-07, DCH Commercial Centre No. 25, Westlands Road,
Quarry Bay, Hong Kong
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: idec@idechk.com
IDEC IZUMI (Shanghai) Co., Ltd.
Room E, 15F, Majesty Building, No. 138 Pudong Avenue,
Shanghai 200120, P.R.C.
Tel: +86-21-5887-9181, Fax: +86-21-5887-8930
E-mail: idec@cn.idec.com
IDEC TAIWAN CORPORATION
8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931