9012GDW6 Product datasheet Characteristics pressure switch 9012G - fixed scale - 1 threshold - 5.0 to 250 psig Commercial status Discontinued on: 01 November 2020 End-of-service on: 03 November 2020 9012GDW6 has not been replaced. Please contact your customer care centre for more information. Discontinued Range of product 9012G Pressure sensor type Electromechanical pressure switch Pressure sensor name 9012G Pressure sensor size 1723.69kPa Maximum pressure 750 psi Contacts type and composition NC-NO, SPDT-DB, Form Z, snap action, silver nickel contacts Controlled fluid Hydraulic oil (-40...121C) Non-corrosive liquids Air Non-corrosive gas Fluid connection type 0.25 inch 18 NPTF conforming to UL 508 Pressure switch type of operation Detection of 1 single threshold Scale type Fixed Local display Without Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Main Complementary Range on decreasing pressure 34.47...1723.69kPa Approx fix differential at mid range 68.95kPa +/- 2.5 % full scale Cable entry 0.5 inch NPT conduit entrance Terminal block type 4 screw terminals Electrical connection Screw-clamp terminals, AWG 22...AWG 12 Electrical circuit type Control circuit Local signalling Without: [In] rated current 3A 240 V AC A600 conforming to NEMA rating designation 6A 120 V AC A600 conforming to NEMA rating designation 0.27A 250 V DC R300 conforming to NEMA rating designation 0.22A 125 V DC R300 conforming to NEMA rating designation Setting Internal Enclosure material Die cast aluminium alloy 380 Pressure actuator Diaphragm nitrile (Buna-N) Height 140.97mm Depth 66.80mm Nov 30, 2020 1 Width 88.90mm Operating position Any position Materials in contact with fluid Nitrile (Buna-N) Zinc plated steel Short-circuit protection 10A cartridge overload and short-circuit protection, type gL Maximum operating rate 120cyc/mn Mechanical durability 5000000cycles Repeat accuracy 4% Net weight 1.36kg Environment Vibration resistance 2 gn (f= 40...150Hz) conforming to IEC 68-2-6 Shock resistance 50 gn conforming to IEC 58-2-27 Standards CE CSA C22.2 No 14 UL 508 Product certifications CSA LR25490 class 3211 03 UL listed file E12158 CCN NKPZ and CCN NTHT CE NEMA degree of protection NEMA 4/4X/13 conforming to UL 50 Ambient air temperature for operation -23...85C Packing Units Package 1 Weight 1.261kg Package 1 Height 61.290cm Package 1 width 24.130cm Package 1 Length 155.677cm Offer Sustainability REACh Regulation REACh Declaration EU RoHS Directive Not applicable, out of EU RoHS legal scope Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information Contractual warranty Warranty 2 18 months