Multiple-Output Model Selection (Cont.) – 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
MODEL OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V
MAP110-4010 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 2% 1% 11.97V to 12.03V
-5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V
-12V Fixed 3A/4A PK 3A/4A PK 0.3% 8% 1% -11.5V to -12.5V
+5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V
MAP110-4011 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V
-12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V
+24V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 23.2V to 24.8V
+5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V
MAP110-4015 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V
-15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.4V to -15.6V
+15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 14.4V to 15.6V
+12V 11.55V to 12.45V 5A/9A PK 5A/9A PK 0.2% 0.5% 0.5% 11.96V to 12.03V
MAP110-4200 +24V Fixed 4A/4.5A PK 4A/4.5A PK 0.2% 1% 1% 23.94V to 24.06V
-12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V
+5V Fixed 2A/2.5A PK 2A/2.5A PK 0.2% 1.5% 1% 4.75V to 5.25V
+3.3V 3.2V to 3.4V 12A/20A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V
MAP110-4300 +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V
(Note 3) -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V
+12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V
+3.3V 3.2V to 3.4V 12A/15A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V
MAP110-4305 +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V
(Note 3) -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -4.75V to -5.25V
+12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V
NOTES: 1) Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
Maximum Output Rtating:
MODEL/OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT
OPTION BOARD ONLY BOARD ONLY ‘L’-BRACKET ‘L’-BRACKET ‘C’-COVER C’-COVER
CONVECTION
CONTINUOUS/PEAK 80W/110W 90W/120W 80W/110W 90W/120W 60W/110W 65W/120W
FORCED AIR
200 LFM 110W 120W 110W 120W 110W 120W
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 85 264 VAC
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC
Hold-up Time Nominal AC input voltage (110 VAC) 50% load: 40 mS
Full rated load: 20
Input Current 85 VAC (110W load). 3.5 ARMS
110VAC (110W load). 2.8
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C. 41 APK
Operating Frequency Switching frequency of main transformer, (fixed frequency). 20 25 kHz
MAP110 AC-DC Series Data Sheet
MCD10142 Rev. 2.0, 23-Aug-11 Page 2 of 5 www.power-one.com