1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*1
C
: with Coating
G
: Low leakage current
H
:
with the function to be acceptable
to output peak current
(Only 24V, 30V, 36V and 48V)
J :
EP (Tyco Electronics) connector type
(Except 3.3V and 5V)
J1
:
VH (J.S.T.) connector type
(Except 3.3V and 5V)
R
: with Remote ON/OFF
R2
:
with Remote ON/OFF
S
: with Chassis
SNF
:
with Chassis & cover & fan
(Only 5V, 12V and 24V)
T1
:
Holizontal terminal block
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
LFA300F-3R3-TY
LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY
LFA300F-24-HTY
LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY
MAX OUTPUT WATTAGE[W]
*5
198 300 324 330 336 336 (456) 330 338.4 336
DC OUTPUT
*5
Convection 3.3V 40A 5V 40A 12V 17A 15V 14A 24V 12.5A
24V 12.5 (19)A
30V 10A 36V 8.4A 48V 6.3A
Forced air 3.3V 60A 5V 60A 12V 27A 15V 22A 24V 14A
24V 14 (19)A
30V 11A 36V 9.4A 48V 7A
SPECIFICATIONS
MODEL
LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY
INPUT
VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*4
CURRENT[A]
ACIN 100V
2.7typ (Io=100%)
4.1typ (Io=100%)
ACIN 200V
1.4typ (Io=100%)
2.0typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
75.0typ 79.0typ 80.0typ 81.5typ 85.0typ 85.0typ 85.5typ 85.5typ 85.5typ
ACIN 200V
77.0typ 82.5typ 83.0typ 84.5typ 88.0typ 88.0typ 88.0typ 88.0typ 88.0typ
POWER FACTOR (Io=100%)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.92typ 0.95typ
INRUSH CURRENT[A]
ACIN 100V
15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 200V
30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 3.35 12152424303648
CURRENT[A]
*5
Convection
40 40 17 14 12.5
12.5 (Peak19)
10 8.4 6.3
Forced air
60 60 27 22 14
14 (Peak19)
11 9.4 7
LINE REGULATION[mV]
*7
20max 20max 48max 60max 96max 96max 144max 144max 192max
LOAD REGULATION[mV]
*7
40max 40max 100max 120max 150max 150max 240max 240max 240max
RIPPLE[mVp-p]
0 to +40C
*2
80max 80max 120max 120max 120max 240max 150max 150max 150max
-10 - 0C
*2
140max 140max 160max 160max 160max 320max 200max 200max 200max
RIPPLE NOISE[mVp-p]
0 to +40C
*2
120max 120max 150max 150max 150max 300max 250max 250max 250max
-10 - 0C
*2
160max 160max 180max 180max 180max 360max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +40C
50max 50max 120max 150max 240max 240max 360max 360max 480max
-10 to +40
C
60max 60max 150max 180max 290max 290max 450max 450max 600max
DRIFT[mV]
*
3
20max 20max 48max 60max 96max 96max 144max 144max 192max
ST ART -UP TIME[ms] 350typ (ACIN 100V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63 4.50 to 5.50
10.80 to 13.20 13.50 to 16.50 21.60 to 27.50 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80
OUTPUT V OL T AGE SETTING[V] 3.30 to 3.40 5.00 to 5.15
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION
4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT.RC
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
OUTPUT.RC-FG
*6
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
OUTPUT-RC
*6
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
ENVIRONMENT
OPERA TING TEMP .,HUMID.AND AL TITUDE
*4
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
STORAGE TEMP .,HUMID.AND AL TITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A)
*8
OTHERS CASE SIZE/WEIGHT
95X52.5X222mm
[3.74X2.07X8.74 inches]
(WXHXD) (without terminal bloc k) / 810g max (with chassis & cover : 1,270g max)
COOLING METHOD Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2)
*4
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*1 Specification is changeed at option, refer to Instruction Manual.
*2 This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*3 Dr ift is the change in DC output for an eight hour period after a
half-hour warm-up at 25C, with the input voltage held constant
at the rated input/output.
*4 Derating is required.
*5 ( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded. Please
contact us about the detail.
*6 Applicable when remote control (optional) is added.
*7 Please contact us about dynamic load and input response.
*8 Please contact us about another class.
* To meet the specifications. Do not operate over-loaded
condition.
* Parallel operation is not possible.
* Derating is required when operated with chassis and cover.
* Sound noise may be generated by power supply in case of
pulse load.
Please refer to Instruction manual 5.
LFA
melfa.inddLFA-18me lfa indd LFA-18 2015/06/1910:40:102015/06/19 10:40:10