Hubbell Motion Sensing Switches H-MOSS(R) Occupancy and Vacancy Sensors H-MoSS (R) Hu bbe ll M h otion Sensing Switc es Tomorrow's Technology Today! Adaptive Technology * Dual Technology Ultrasonic * Passive Infrared Technology for Today's Needs H-MOSS(R) Occupancy Sensors feature the latest in technological advances. Adaptive Technology Adaptive Technology is a Hubbell breakthrough that delivers benefits to the building owner and occupants. The building owner gets reduced energy costs, fewer adjustments and less maintenance. The building occupant experiences fewer false-offs, disturbances and lower energy costs. Adaptive technology sensors use microprocessor-based technology which makes all the decisions for setting adjustments. Internal software constantly monitors the controlled area and automatically adjusts the sensitivity and timer based on environmental history. This means that instead of manually adjusting the sensor for seasonal changes, modified airflow, and furniture layout or occupancy pattern changes, the sensor will automatically adjust itself. These automatic adjustments will eliminate the need for multiple adjustments by maintenance, personnel or outside contractors. Hubbell offers adaptive technology throughout its product offering (wall switches, ceiling and wall mount sensors) in conjunction with dual technology (ultrasonic and passive infrared), ultrasonic, and passive infrared products. Dual Technology Dual technology occupancy sensors use both passive infrared and ultrasonic technologies for maximum reliability. These sensors also minimize the risk of false triggering (lights coming on when the space is unoccupied). Both ultrasonic (US) and passive infrared (PIR) technologies must detect occupancy to turn lighting on, while continued detection by only one technology will keep lighting on. The dual technology sensors are the best performing sensor for most applications. Ultrasonic (US) Ultrasonic technology senses occupancy by bouncing ultrasonic sound waves (32kHz - 45kHz) off objects in a space and detecting a frequency shift between the emitted and reflected sound waves. Movement by a person or object within the space causes a shift in frequency, which is interpreted as occupancy. Ultrasonic occupancy sensors are good at detecting minor motion (e.g. typing, reading) and do not require an unobstructed line-of-sight, thus making them suitable for applications such as an office with cubicles or a restroom with stalls. 2 Passive Infrared (PIR) Passive Infrared (PIR) technology senses occupancy by detecting the difference between heat emitted from the human body and the background space. PIR sensors require an unobstructed line-of-sight for detection. These sensors utilize a segmented lens, which divides the coverage area into zones. Movement between these zones is interpreted as occupancy. PIR sensors are good at detecting major motion (e.g. walking) and work best in small, enclosed spaces with high levels of occupant movement. Energy Savings with Occupancy Sensors Typical Applications Location Passive Ultrasonic Infrared (PIR) Bedroom Cafeteria Closet Conference Room Classroom Wall Switch Ceiling Sensor Wall Sensor Library Rest Room (multi-stall) Occupancy Sensors = Energy Savings Lecture Hall Hallway Applications are generalized. Consult your Hubbell representative for the type of technology and products that fit your needs. Dual Sensor Style Technology Private Office Storage Lobby Warehouse Potential Energy Savings Using Occupancy Sensors Energy Savings Percentage Range Source: Esource For many years, occupancy sensors Open Office have been highlighted as a way to reduce Private Office energy consumption. The California Department of Energy has stated that Classroom lighting accounts for 35-45% of an office buildings energy use. Conference Room As seen in the chart, occupancy sensors can potentially reduce lighting use by Storage Room 13-90%. In a large office building, for example, occupancy sensors can be an Restroom excellent way of reducing energy costs for 10% 20% 30% 40% 50% 60% 70% 80% 90% both building operators and tenants. Return on Investment (ROI) Occupancy sensors can save a building operator or tenant money, but what is the return on investment (ROI) for a capital expenditure of this nature? Hubbell has developed a tool, the H-MOSS(R) ROI Worksheet, that can be accessed from the Hubbell website, www.hubbell-wiring.com, or from a Hubbell representative. This simple-to-use worksheet helps calculate present annual energy costs without sensors and estimated annual costs with sensors. The savings and short payback time can be surprising. H-MOSS(R) ROI Worksheet H-MOSS(R) Occupancy Sensors Return On Investment (ROI) Calculation Worksheet # Units* X Watts Per Unit** = Total Watts / 1000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Annual Savings $0.00 * = Total KW X Utility Rate Per KWH X Annual Operating Hours 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Payback Calculation Material Costs Labor Costs X % Savings = Totals: Payback in Months*** #DIV/0! Fluorescent Lamps, Incandescent Lamps, CRTs, Task Lighting. ** Total wattage of fixture including ballast *** Payback in months=((Material Cost + Labor Cost)/Annual Savings)*12 As energy costs continue to climb, standards and codes become more stringent, and the "greening" of commercial and residential buildings increases across the country, you should look toward Hubbell Occupancy Sensors to help decrease your energy costs. Layout Capabilities and Technical Support Hubbell representatives are available to meet and discuss any project, large or small. We can provide an occupancy sensors layout based on blueprints, either in electronic or paper form and a bill of material (BOM). All questions can be addressed by our technical service group that is always available. 3 Annual Savings $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Reduce Energy Reduce Energy Consumption and Meet Federal and State Standards and Guidelines Reduction of energy consumption at all levels: local, state and national is critical. Today's buildings, both commercial and residential new and renovated - must follow new state and federal standards and codes which call for energy efficiency throughout a facility. LEED LEED (Leadership in Energy and Environmental Design) which is sponsored by the U.S. Green Building Council (USBC) has created a rating system to define what constitutes a green building by establishing common standards of measurement, and promoting integrated and whole building design. This certification applies to both new and renovated commercial buildings. Points are awarded by category and there are four levels of certification- certified, silver, gold and platinum. H-MOSS, Hubbell Motion Sensor Switches offer a large array of occupancy sensors, which can be utilized to help increase energy efficiency in the following categories: LEED Credit Categories Sustainable Sites- SS Light pollution reduction Energy and Atmosphere- EA Optimize energy performance Indoor Environment Quality- EQ Controllability of systems, lighting Innovation & Design Process- ID Innovation in design 4 Energy Savings and Codes ASHRAE/IESNA 90.1 Standard Among the requirements in this standard is that a building of 5,000 sq. ft. or more, except for lighting operated 24 hours per day, must incorporate automatic control devices to turn off all lighting. IECC 2003 Lighting Control Provision The International Energy Conservations Code (IECC) which has been adopted by some states, affects new construction, additions and alterations for all commercial buildings, including residential structures with four or more stories above grade. It requires an automatic shutoff of all lighting for buildings larger than 5,000 sq. ft. with occupancy sensors as one way to achieve this goal. California Energy Commission (CEC) Title 24 Program California's Title 24 Program sets up some of the most stringent standards and regulations in the country to reduce energy consumption in both commercial and residential structures. Some of the key provisions are: Multi-level lighting control Any enclosed space 100 sq. ft. or larger which has a connected lighting load that exceeds 0.8 watts per sq. ft. and has more than one light source (luminaire) shall be controlled so that the load for lights may be reduced by a minimum of 50%. Area controls Each area enclosed by ceiling height partitions must have an independent switching or control device- occupancy sensor or manual switch. Automatic shut-off controls For every floor, all indoor lighting must have a separate automatic control, capable of automatically shutting off the lighting. Residential buildings In 2005, Title 24 simplified and expanded the standard to include use of high efficacy luminaires, manual-on occupancy sensors, fluorescent lights or dimmers in most rooms of the home such as bedrooms, bathroom, garage, living room, hallway, and utility room. Hubbell offers many models of occupancy, vacancy and dimmers (all CEC Title 24 compliant) that will enable builders, contractors and homeowners to meet these new requirements. 5 H-MOSS(R) Wall Switches Featuring Adaptive Technology All H-MOSS Wall Switches with Adaptive Technology featured below have the following standard features: * Adaptive technology - "Install and forget" operation * All digital sensing technology * Dual 120/277V AC operation * Auto or manual "On" operating modes * No minimum load requirements * Hard lens (dual technology, passive infrared) * Zero arc point switching * Built in photocell with manual super saver mode for daylight harvesting * Two relays for two level switching or dual load control (AD, AP AU1277x2, 2N series) * C-UL US AD1277W1 Adaptive Technology, Dual (Ultrasonic and Passive Infrared) 50/60Hz, 1000 sq. ft. coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC Circuit Button Color Catalog Numbers Single 1 Button for manual/auto control Ivory AD1277I1 White AD1277W1 Single Auto control with no button Ivory AD1277I1N White AD1277W1N Dual 2 Buttons for manual/auto control Ivory AD1277I2 White AD1277W2 Dual Auto control with no button Ivory AD1277I2N White AD1277W2N AD1277W1N AD1277W2N Sensors are available in three special order colors. To order special order colors, replace "I or W" with the following: LA (Light Almond), GY (Gray) or BK (Black). Special order colors have minimum ordering requirements and minimum lead times. Please call Customer Service for further information. Wallplates are sold separately. Ultrasonic Major Motion Ultrasonic Minor Motion Passive Infrared 26' 21' AD1277W2 28' 29' 24' 28' 50' Adaptive Technology, Ultrasonic 50/60Hz, 400 sq. ft. coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC Circuit Button Color Catalog Numbers Single 1 Button for manual/auto control Ivory AU1277I1 White AU1277W1 Single Auto control with no button Ivory AU1277I1N White AU1277W1N Dual 2 Buttons for manual/auto control Ivory AU1277I2 White AU1277W2 Dual Auto control with no button Ivory AU1277I2N White AU1277W2N Sensors are available in three special order colors. To order special order colors, replace "I or W" with the following: LA (Light Almond), GY (Gray) or BK (Black). Special order colors have minimum ordering requirements and minimum lead times. Please call Customer Service for further information. Wallplates are sold separately. 26' Ultrasonic Major Motion Ultrasonic Minor Motion AU1277W1 AU1277W1N AU1277W2N 21' 14.5' 24' AU1277W2 14.5' 6 H-MOSS(R) Wall Switches and Wall Mount Sensors Featuring Adaptive Technology Adaptive Technology, Passive Infrared 50/60Hz, 1000 sq. ft. coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC Circuit Button Color Catalog Numbers Single 1 Button for manual/auto control Ivory AP1277I1 White AP1277W1 Single Auto control with no button Ivory AP1277I1N White AP1277W1N Dual 2 Buttons for manual/auto control Ivory AP1277I2 White AP1277W2 Dual Auto control with no button Ivory AP1277I2N White AP1277W2N AP1277W1 Sensors are available in three special order colors. To order special order colors, replace "I or W" with the following: LA (Light Almond), GY (Gray) or BK (Black). Special order colors have minimum ordering requirements and minimum lead times. Please call Customer Service for further information. Wallplates are sold separately. Passive Infrared AP1277W1N AP1277W2N 28' 28' 50' Adaptive Technology Wall Mount Sensors * Adaptive Technology - "Install and forget" operation * Swivel mounting bracket included for wall or ceiling mounting * All digital sensing technology * Photocell for daylight harvesting and relay interface with auxiliary systems such as HVAC (WRP and HBRP models) * 24V DC, 33MA AP1277W2 Dual (Ultrasonic and Passive Infrared) Description 32kHz, with photocell and isolated relay Coverage 1600 sq. ft. Color White Catalog Numbers ATD1600WRP 32kHz 1600 sq. ft. White ATD1600W Coverage 1600 sq. ft. Color White Catalog Numbers ATP1600WRP 1600 sq. ft. White ATP1600W 120 linear ft. White ATP120HBRP 120 linear ft. White ATP120HB Passive Infrared Description With photocell and isolated relay For aisle and high bay applications, with photocell and isolated relay For aisle and high bay applications ATD1600WRP ATD1600W Note: All wall mount sensors must use a CU series control unit. See page 11 for details. Ultrasonic Major Motion Ultrasonic Minor Motion Passive Infrared 23' 32' 30 0 10 20 30 40 50 ATP1600WRP ATP1600W ATP120HBRP ATP120HB 20 10 32' 0 Side View 23' 7' 20' 20' 40' ATD1600WRP, ATD1600W 40' ATP1600WRP, ATP1600W 7 7' Top View H-MOSS(R) Wall Switches Passive Infrared Sensors Adaptive Technology, Passive Infrared * Adaptive technology - "Install and forget" operation * Passive infrared technology * Dual 120/277V AC operation * Heavy duty relay (AT1277) Description One Button One Button * Audible alarm before sensor turns lights off (AT1277) * 1200 sq. ft. coverage * Built in photocell for daylight harvesting * Nylon wallplate included 120V AC 277V AC Color 1800W Incandescent 4155W Fluorescent Ivory White 800W Incandescent 1200W Fluorescent Ivory 800W Fluorescent White Gray Passive Infrared Catalog Numbers AT1277I AT1277W ATP1277I ATP1277W ATP1277GY 40' 10' (3.0m) 16' 20' (6.1m) AT1277W 29" (73.3cm) 14.5" (36.8cm) 3.5 3.5 ATP1277W Mounting Height 42" to 54" (106.7 to 137.2cm) 16' Horizontal Coverage See Horizontal View for Range Vertical Coverage Passive Infrared Wall Switches * Passive infrared technology * Manual adjustment time delay (WS1277 - 20 sec. to 30 min.) (WS120/WS277 - 30 sec. to 30 min.) * Photocell (WS1277I, WS1277W) * Dual level switching from one or two circuits (WS1277W2) * Nylon wallplate included (except WS1277W2) Description Coverage 120V AC 277V AC Color One button 1200 800W 1200W Ivory 120/277V AC sq. ft. White One button, 900 800W Incandescent N/A Ivory 120V AC sq. ft. 1000W Fluorescent White One button, 900 N/A 1800W Ivory 277V AC sq. ft. Fluorescent White Double pole 1000 600W Incandescent* 1800W White switch, sq. ft. 1000W Fluorescent* Fluorescent 120/277V AC Two-gang adapter wallplate for WS1277W2 to mount to a two-gang box *per circuit Passive Infrared 40' WS1277W WS1277W2 WSAP 36' WS120W 35' 40' 36' 16' 16' 16' 16' Catalog Numbers WS1277I WS1277W WS120I WS120W WS277I WS277W 16' WS1277 36' 16' WS120, WS277 WS1277W2 8 WS1277W2 H-MOSS(R) Wall Switches Residential and Vacancy Sensors Residential Occupancy Sensors - Passive Infrared Passive infrared technology Photocell equipped for daylight harvesting Auto-on, auto-off Delayed off adjustment from 30 seconds to 30 minutes * * * * Description Single pole switch with button, 150 view Single pole switch with dimming, 150 view Heavy duty switch, 180 view * Patent pending "alert to off" feature dims lights prior to going off (RMS101&121) * Wallplate included * C-UL US RMS101W Coverage 120V AC 277V AC 800 sq. ft. 500W N/A Incandescent Color Ivory White Almond Light Almond 800 sq. ft. 500W N/A Ivory Incandescent White Almond Light Almond 900 sq. ft. 800W 1800W Ivory Incandescent Fluorescent White 1000W Almond Fluorescent Catalog Numbers Standard Nightlight RMS101I RMS101ILI RMS101W RMS101ILW RMS101AL RMS101ILAL RMS101LA RMS101ILLA RMS121I RMS121ILI RMS121W RMS121ILW RMS121AL RMS121ILAL RMS121LA RMS121ILLA RMS141I -- RMS141W -- RMS141AL -- RMS121W RMS121ILW Vacancy Sensors - Passive Infrared - CA Title 24 Compliant * Delayed off, adjustment from 30 seconds to 30 minutes * Wallplate included * C-UL US * Passive infrared technology * Manual-on, auto-off * Patent pending "alert to off" feature dims lights prior to going off (RMS100 & 120) Description Single pole switch with button, 150 view Single pole switch with dimming, 150 view Heavy duty switch, 180 view Coverage 120V AC 277V AC 800 sq. ft. 500W N/A Incandescent Color Ivory White Almond Light Almond 800 sq. ft. 500W N/A Ivory Incandescent White Almond Light Almond 900 sq. ft. 800W 1800W Ivory Incandescent Fluorescent White 1000W Almond Fluorescent Passive Infrared 14' 16' 35' Catalog Numbers Standard Nightlight RMS100I RMS100ILI RMS100W RMS100ILW RMS100AL RMS100ILAL RMS100LA RMS100ILLA RMS120I RMS120ILI RMS120W RMS120ILW RMS120AL RMS120ILAL RMS120LA RMS120ILLA RMS140I -- RMS140W -- RMS140AL -- RMS100W RMS120W 40' 16' 16' 14' RMS141W 15 5 5 Mounting Height 36" to 54" (91.44 to 137.16 cm) Mounting Height 36" to 54" (91.44 to 137.16 cm) 16' 35' 35' Horizontal Coverage Vertical Coverage RMS101, RMS121, RMS100, RMS120 15 35' Horizontal Coverage Vertical Coverage RMS141, RMS140 9 RMS120ILW RMS140W H-MOSS(R) Ceiling Sensors Featuring Adaptive Technology All H-MOSS ceiling sensors with Adaptive Technology contain the following standard features: * Adaptive Technology- "Install and forget" * All digital sensing technology * Photocell for daylight harvesting and relay to interface with auxiliary systems such as HVAC (CRP models) * Non-volatile memory- learned and adjusted settings retained after power outage * 24V DC, 33mA * 32kHz (ATD/ATU500C & CRP - 400kHz) * Mounting base included with sensor Adaptive Technology, Dual (Ultrasonic and Passive Infrared) Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared (PIR) long-range major motion detection Coverage Color Catalog Numbers 2000 sq. ft. with photocell and isolated relay White ATD2000CRP 2000 sq. ft. White ATD2000C 1000 sq. ft. with photocell and isolated relay White ATD1000CRP 1000 sq. ft. White ATD1000C 500 sq. ft. with photocell and isolated relay White ATD500CRP 500 sq. ft. White ATD500C ATD1000CRP ATD1000C ATD500CRP ATD500C Note: All ATD ceiling sensors must use a CU series control unit. See page 11 for details. Passive Infrared Ultrasonic Major Ultrasonic Minor 22' 12' 12' 32' 23' ATD2000CRP ATD2000C 22' 32' 23' 45' 23' 32' 64' ATD2000CRP, ATD2000C ATD1000CRP, ATD1000C Adaptive Technology, Ultrasonic Excellent minor motion detection Coverage 2000 sq. ft. with photocell and isolated relay 2000 sq. ft. 1000 sq. ft. with photocell and isolated relay 1000 sq. ft. 500 sq. ft. with photocell and isolated relay 500 sq. ft. Color White White White White White White Catalog Numbers ATU2000CRP ATU2000C ATU1000CRP ATU1000C ATU500CRP ATU500C ATU2000CRP ATU2000C Note: All ATU ceiling sensors must use a CU series control unit. See page 11 for details. Ultrasonic Major Ultrasonic Minor 45' 64' 32' 23' 23' ATU1000CRP ATU1000C ATU500CRP ATU500C 32' 32' 23' 56' 16' ATU2000CRP, ATU2000C ATU1000CRP, ATU1000C ATU2000CRP, ATU2000C Hallway Application 10 H-MOSS(R) Ceiling Sensors Featuring Adaptive Technology, Control Units, Add-A-Relay and Digital Timer Wall Switch Adaptive Technology, Passive Infrared Outstanding long range major motion detection Description Coverage Wide view lens 1500 sq. ft. with photocell and isolated relay Wide view lens 1500 sq. ft. High density lens 450 sq. ft. with photocell and isolated relay High density lens 450 sq. ft. Color White Catalog Numbers ATP1500CRP White White ATP1500C ATP600CRP White ATP600C Note: All ATP ceiling sensors must use a CU Series control unit. See below for details. Passive Infrared 22' 12' ATP1500CRP ATP1500C ATP600CRP ATP600C ATP1500CRP, ATP1500C Control Units Hubbell CU series control units provide a 24V DC power supply for 1 to 3 sensors or sensor/ Add-A-Relay combinations. The CU300A provides a 24V DC power supply for 1 to 4 sensors or sensor/Add-A-Relay combinations. The control units contain an internal relay for the control of an external lighting load. All control units are plenum rated. Description Catalog Numbers 120/277V AC, 50/60 Hz for use with ATD, ATU and ATP series CU300A ceiling sensors and wall mount sensors 347V AC, 60 Hz, for use with ATD, ATU and ATP series ceiling and CU347A wall mount sensors CU347A, CU300A Add-A-Relay Hubbell AAR Add-A-Relay contains an internal relay for control of an external lighting load. The AAR requires a 24V DC power supply from the Hubbell CU series control unit. The AAR is typically used when: 1. It is desired to switch more than one circuit when occupancy is sensed. 2. The lighting load exceeds the maximum rating of the control unit. Description Catalog Number For use with CU series control units and Hubbell ATD, ATU and ATP AAR series ceiling and wall mount sensors AAR Digital Timer Wall Switch Description 120V AC 277V AC Color Dip switch enabled preset intervals - 5,15 or 30 minutes - 1, 3, 6, 9 or 12 hours Includes an on/off momentary push button switch feature 800W White 1200W Catalog Number DT1277W All Hubbell H-MOSS(R) Occupancy Sensors are covered by a 5 year limited warranty. 11 DT1277W H-MoSS Hubbell Motion Sensing Switches Adaptive Technology * Dual Technology Ultrasonic * Passive Infrared H-MoSS (R) Hu bbe ll M h otion Sensing Switc es Tomorrow's Technology Today! Printed In U.S.A. Specifications subject to change without notice. (R) Registered trademark of Hubbell Incorporated Hubbell Wiring Device-Kellems * Hubbell Incorporated (Delaware) * 185 Plains Road * Milford, CT 06461-2420 Phone (203) 882-4800 * FAX (800) 255-1031 * Website: www.hubbell-wiring.com H5240