For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1Free air convection.
Multiple output units: maximum continuous output power not to exceed
80 W.
For -9693J; I3.3 V = 13 A max.; I5.0 V = 13 A max.; I3.3 V +I
5.0 V ≤16 A.
For -9694J; I3.3 V = 13 A max.; I2.5 V = 13 A max.; I3.3 V +I
2.5 V ≤16 A
For -9695J; I3.3 V = 13 A max.; I12 V = 6.5 A max.; I3.3 V +I
12 V ≤16 A.
For -9608J; I5.0 V = 13 A max.; I12 V = 6.5 A max.; I5.0 V +I
12 V ≤16 A.
Single output units: maximum continuous output power not to exceed; 75
W on –9605J; 76.8 W on –9612J,-9624J, and –9617J.
2150 LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed
105 W.
For -9693J; I3.3 V = 16 A max.; I5.0 V = 16 A max.; I3.3 V +I
5.0 V ≤20 A.
For -9694J; I3.3 V = 16 A max.; I2.5 V = 16 A max.; I3.3 V +I
2.5 V ≤20 A
For -9695J; I3.3 V = 16 A max.; I12 V = 8.5 A max.; I3.3 V +I
12 V ≤20 A.
For -9608J; I5.0 V = 16 A max.; I12 V = 8.5 A max.; I5.0 V +I
12 V ≤20 A.
Single output units: maximum continuous output power not to exceed
110 W for all models.
3300 LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed
110 W.
For -9693J; I3.3 V = 20 A max.; I5.0 V = 18 A max.; I3.3 V +I
5.0 V ≤22 A.
For -9694J; I3.3 V = 20 A max.; I2.5 V = 20 A max.; I3.3 V +I
2.5 V ≤22 A
For -9695J; I3.3 V = 20 A max.; I12 V = 8.5 A max.; I3.3 V +I
12 V ≤22 A.
For -9608J; I5.0 V = 20 A max.; I12 V = 8.5 A max.; I5.0 V +I
12 V ≤22 A.
Single output units: maximum continuous output power not to exceed
110 W for all models.
4Peak output current lasting less than 30 seconds with duty cycle less
than 5%. During peak loading, output voltage may exceed total
regulation limits.
5Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6” twisted
pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic
capacitor.
6Minimum load required for correct start-up and operation on single
outputs and on main output of multiple versions. Failure to observe
minimum load on main output will not allow the supply to start-up
correctly. Some electronic test loads have a large delay time before they
start drawing current even though the voltage from the supply is present.
During this time delay, there is no load on the output and as a result, the
supply cannot start-up properly and maintain its correct output voltage.
In these instances, a dummy resistive load across the output may be
necessary to load the output of the supply until the test load can function
correctly and draw the intended minimum load. Minimum load required
on auxiliary outputs to maintain regulation.
N
7For models NLP110-9608J and NLP110-9695J, the 12 V output is
floating. For -12 V output, pin 11 on J2 has to be connected to Return
making pin 12 the -12 V output
8Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
9For optimum reliability, no part of the heatsink should exceed 110 ºC,
and no semiconductor case temperature should exceed 120 ºC.
10 CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
11 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
12 The EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond
each edge, using an unshielded cable. No external filtering required
during conducted emissions testing but some applications may require
additional filtering to achieve system compliance. A line choke, (ac input
cords looped twice through an EMI suppression toroid) was used during
radiated emissions testing. Considerable radiated testing in 1U six-sided
boxes has shown that units can meet level B in typical systems.
Application support is available from the factory to assist with EMI
compliance.
13 All models require a minimum mounting stand-off of 6.35 mm (0.25
inches) in the end use product.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
NLP110 Series
Single and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies 2
File Name: nlp110.pdf Rev (02): 08 Nov 2005
OUTPUT OUTPUT CURRENT
RIPPLE (5) TOTAL MODEL
VOLTAGE MIN (6) MAX (1) 150 LFM (2) 300 LFM (3)
PEAK (4)
REGULATION NUMBERS (7,14,15)
+5 V 0.5 A 15 A 22 A 22 A 22 A 50 mV ±2.0% NLP110-9605J
+12 V 0.3 A 6.4 A 9.2 A 9.2 A 11.5 A 120 mV ±2.0% NLP110-9612J
+48 V 0 A 1.6 A 2.3 A 2.3 A 2.5 A 240 mV ±2.0% NLP110-9617J
+24 V 0.2 A 3.2 A 4.6 A 4.6 A 6.0 A 240 mV ±2.0% NLP110-9624J
+5 V (A) 0.5 A 13 A 16 A 18 A 18 A 50 mV ±2.0% NLP110-9693J
+3.3 V (B) 0.2 A 13 A 16 A 20 A 20 A 50 mV ±2.0%
+12 V 0 A 0.65 A 1.0 A 1 A 1 A 120 mV ±5.0%
+3.3 V (A) 0.5 A 13 A 16 A 20 A 22 A 50 mV ±2.0% NLP110-9694J
+2.5 V (B) 0.1 A 13 A 16 A 20 A 22 A 50 mV ±2.0%
+12 V 0 A 0.65 A 1 A 1 A 1 A 120 mV ±5.0%
+12 V (A) 0.2 A 6.5 A 8.5 A 8.5 A 10 A 1200 mV ±2.0% NLP110-9695J
+3.3 V (B) 0.5 A 13 A 16 A 20 A 22 A 50 mV ±2.0%
-12 V 0 A 0.65 A 1 A 1 A 1 A 120 mV ±5.0%
+12 V (A) 0.2 A 6.5 A 8.5 A 8.5 A 10 A 120 mV ±2.0% NLP110-9608J
+5 V (B) 0.2 A 13 A 16 A 18 A 22 A 50 mV ±2.0%
-12 V 0 A 0.65 A 1 A 1 A 1 A 120 mV ±5.0%