1641-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWX Series
Features
u 90 - 150W convection cooled ratings
u 1U high
u Power factor corrected
u Peak power ratings
u No minimum loading required
180W to 300W Industrial ATX Power Supplies
(1) With output loading of:
ZWX180: V1=6.5A, V2=6.5A, V3=7.7A, V4=0.2A, V5=1A
ZWX240: V1=8.9A, V2=7.7A, V3=10.2A, V4=0.3A, V5=2A
ZWX300: V1=12A, V2=7A, V3-1=5A, V3-2=9.4A, V4=0.2A, V5=1A
(2) 100/200VAC
(3) Avoid prolonged operation in overload
(4) <5s operation at peak load
Model ZWX180 ZWX240 ZWX300
Input Voltage V 85-265VAC (47-63Hz)
Input Current (1)(2) A 1.9 / 1.0 2.6 / 1.3 3.2 / 1.6
Inrush Current (2) A 14 / 28 Cold start 25°C ambient
Power Factor - Meets EN61000-3-2
Leakage Current mA < 0.75mA
Temperature Coeffi cient °C <0.02%/°C
Overcurrent Protection (3) - >1.05% of forced air current rating (5s delay and manual reset on V1, 2 & 3)
Overvoltage Protection (4) V +3.3V: 3.76 - 4.3V, +5V: 5.74 - 7V, +12V: 13.4 - 15.6V
Hold Up Time (Typ) (1) ms 20ms at 100VAC
Effi ciency (1)(2) % 81 / 84%
Remote On/Off PS_ON - High: Unit off, Low: Unit On (enabled). Meets SFX 12V
DC Good PWR_OK - High: Power supply is good. Meets SFX12V
Remote Sense - +3.3V Only
Output Voltage Setpoint Accuracy - ±5% (all outputs)
Output Voltage Adjustment - None
Line Regulation mV 3.3V: 20mV, 5V: 48mV, +12V: 48mV, -12V: 20mV, +5Vsb: 20mV
Load Regulation mV 3.3V: 100mV, 5V: 300mV, +12V: 300mV, -12V: 100mV, +5Vsb: 100mV
Ripple & Noise mV 3.3V: 120mV, 5V: 150mV, +12V: 150mV, -12V: 120mV, +5Vsb: 120mV
Operating Temperature - -10°C to +70°C, derate linearly to 20% load from 50°C to 70°C
Storage Temperature °C -30 to +85°C
Humidity (non condensing) - Operating: 30 - 90%RH, Non operating: 10 - 95% RH
Cooling - Convection or forced air cooled (30CFM, 0.85m3/min)
Withstand Voltage - I/P to Grnd 2kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to Grnd 500VAC (100mA) for 1 min.
Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock (non operating) - < 392m/s2
Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, EN50178 (OV II), CE Mark
Conducted & Radiated EMI - EN55011/EN55022-B, FCC Class B, VCCI-B
Immunity - EN61000-4-2, -3, -4, -5, -6, -8, -11
Weight (Typ) g 500 650 800
Size (WxHxD) in 3.7 x 1.42 x 8.27 4.17 x 1.42 x 8.86 4.65 x 1.42 x 9.84
Warranty yrs Three Years
Specifi cations
Key Market Segments & Applications