Amprobe® Test Tools www.Amprobe.com
Data Sheet
Specifications
Update Rate 5 per second nominal
Operating Temperature -10ºC ~ 55ºC (14ºF ~ 131ºF)
Relative Humidity Maximum relative humidity 80% for temperature up to 31ºC (87ºF) decreasing linearly to 50%
relative humidity at 55ºC (131ºF)
Altitude Operating below 2000m
Storage Temperature -20ºC ~60ºC (-4ºF ~ 140ºF), < 80% R.H. (with battery removed)
Temperature C oefficient Nominal 0.15 x (specified accuracy)/ ºC @ (-10ºC ~ 18ºC or 28ºC ~ 55ºC), or otherwise specified
Sensing Average sensing
Type of Protection IP65
Pollution Degree 2
E.M.C. Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11): For both models:
Performance is specified in an RF Field of 3V/m. Performance above 3V/m is not specified.
Safety Meets EN61010-1 and IEC61010-1 2nd Edition (2001)
Measurement Category CAT III 1000V & CAT IV 600V AC & DC
Transient Protection 8kV lightning surge (1.2/50µs)
Overload Protection 1000VDC & VAC rms
Low Battery Below approx. 2.4V
Power Supply Standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03)
alkaline battery X 2
Power Consumption (typical) 3mA at Power-on ready; 30mA at 1000VAC full LED indication. 75mA at 1000VAC with shaker ON
APO Consumption (typical) 10µA
APO Timing Idle for 30 seconds
Dimension 233(L) x 57(W) x 40(H)mm(9.17 x 2.24 x 1.57 in)
Weight Approx. 220 g (0.485 lb)
Special Features High Input Impedance, Indicator Self-Test, Auto-Hold, Overload-Alert Warning, EF-Detection,
AC-Detection Shaker, Bi-Color LED Hazardous Live Warning
Accessories Detachable (Black) Test Lead, Screw-on Stationary (Red) Probe, 2 Screw-on 4mm Probe Tips,
batteries installed and User’s manual
VPC-30 Voltage & Continuity Tester