CSM_H8BM-R_DS_E_5_3
1
Multi-maintenance Counter/Timer (DIN 72 x 72)
H8BM-R
Nine Built-in Counters/Timers to
Measure Equipment Operating
Cycles and Times and Forecast
Maintenance Timing
Provides up to nine counters or accumulative timers. (Counter and
timer functions can be used at the same time.)
Individual forecast outputs to indicate maintenance timing.
Pre-forecast display and machine stoppage output provided.
IP54 oil-proof type at setting area for resistance to oil and water.
Separate digit keys to easily change settings.
Compact, short-body: 72 × 72 × 79 mm (DIN).
Key protection function prevents incorrect operation.
Multiple outputs: NPN/PNP.
Directly connectable to 2-wire DC sensors.
Complies with UL and CSA.
Ordering Information
Multi-maintenance Counter/Timer Accessories (Order Separately)
Note 1. A Hard Protective Cover and Rubber Packing are supplied with the
Counter.
2. The H8BM-R@ is provided with short input as standard to achieve a
Multi-stage Counter without having to use a short-circuit plate and
external wiring.
Specifications
The H8BM-R can be used as a multi-stage preset counter.
Refer to Safety Precautions on page 7.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Preset stage Nameplate lettering Model
3-stage setting Japanese H8BM-RA
English H8BM-RB
1-stage setting Japanese H8BM-RAD
English H8BM-RBD
Name Model
Hard Protective Cover (See note 1.) Y92A-72C
Rubber Packing (See note 1.) Y92S-25
Short-circuit plate (See note 2.) Y92S-26
Item Model H8BM-RA/RB H8BM-RAD/RBD
Classification 3-stage setting 1-stage setting
Mounting method Flush mounting
External connections Screw terminals
Degree of protection IP54 oil-proof type (case front)
Input mode Up
Output mode F mode (Operation continues even when setting is reached.)
Reset system External, manual resets
Timer operation Yes
Input method Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O
inhibit)
Control output No-contact outputs: RUN, forecast, machine
stoppage No-contact outputs: RUN, forecast
Display
Count, preset value, counter number, and error codes displayed on 7-segment LCD
Mode, reset, I/O inhibit, re-monitor modes, and key protection displayed on LCD characters
Output indication on LCD characters and LEDs
LCD with backlight Yes
Built-in counter number 9 (counters 1 to 9) (See note 1.)
Preset stage 3-stage (See note 2.) 1-stage (See note 3.)
Digits
Forecast value: 6 digits (999999)
Pre-forecast value: 5 digits (See note 4.)
Machine stoppage: +5 digits (See note 5.)
Forecast value: 6 digits (999999)
Time ranges
Forecast value: 99999.9 h (0.1 h or longer)/
99999.9 s (0.1 s or longer)
Pre-forecast value:9999.9 h/9999.9 s (See
note 4.)
Machine stoppage: +9999.9 h/+9999.9 s (See
note 5.)
Forecast value: 99999.9 h (0.1 h or
longer)/99999.9 s (0.1 s or longer)
Memory backup EEPROM (Data can be written 100,000 times.), Backup time for power interruption: Approx.
10 years
Note 1. Each channel operates on a separate
I/O.
2. The 3-stage are pre-forecast, forecast,
and machine stoppage.
Pre-forecast:
Displayed only on LCD (no
external output is provided).
Forecast: Displayed on LCD and LED
and output (output for each
counter).
Machine stoppage:
Displayed on LCD and LED
and output
(output when the count
value of one or more of
counters 1 to 9 has reached
its machine stoppage
value).
3. This Counter operates on the forecast
value only.
4. The pre-forecast value is set as a
negative offset in respect to the
forecast value.
5. The machine stoppage value is set as
a positive offset in respect to the
forecast value.
H8BM-R
2
Specifications
Ratings
Note 1. Ripple content: 20% max.
2. This signal is output as a carry signal when the Counter is used as a
total counter.
Characteristics
Applicable Standards
Note: Attach a waterproof cover of Y92A-72N.
Rated supply voltage 24 VDC
Operating voltage
range 85% to 110% of rated supply voltage (See note 1.)
Power consumption Approx. 1.7 W (at 26.4 VDC)
Max. counting speed
30 Hz for count inputs 1 to 7,
Switchable between 30 Hz and 500 Hz for count
inputs 8 and 9
Min. counting input
signal width
Count inputs 1 to 7: 16.7 ms (ON:OFF = 1:1)
Count inputs 8 and 9: 16.7 ms/1 ms selectable
(ON:OFF = 1:1)
Reset input: 100 ms max.
Short input: 75 ms max.
Counter number selection input: 30 ms max.
I/O inhibit input: 16.7 ms max.
One-shot time 20 ms (See note 2.)
Count, reset, short,
counter number
selection, and I/O
inhibit input
Voltage input
High level: 16 to 26.4 VDC
Low level: 0 to 3 VDC
(input resistance: approx. 2.2 kΩ)
Control output Open-collector output: 100 mA max. at 30 VDC max.
Surrounding air
temperature 10 to +55°C (with no icing or condensation)
Ambient storage
temperature 25 to +65°C (with no icing or condensation)
Ambient operating
humidity 25% to 85%
Case color Dark gray (Munsell 5Y3/1)
Insulation
resistance
100 MΩ min. (at 500 VDC) (between current-carrying
terminals and exposed non-current-carrying metal parts)
Dielectric
strength voltage
1,000 VAC, 50/60 Hz for 1 min (between current-
carrying terminals and exposed non-current-carrying
metal parts)
Impulse
withstand
voltage
1 kV (between power terminals)
1.5 kV (between current-carrying terminals and exposed
non-current-carrying metal parts)
Noise immunity
±480 kV (between power terminals) and ±480 V
(between input terminals), square-wave noise by noise
simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Malfunction: 8 kV; destruction: 15 kV
Vibra-
tion
resis-
tance
Destruc-
tion
10 to 55 Hz with 0.75-mm single amplitude, 2 hours
each in three directions
Malfunc-
tion
10 to 55 Hz with 0.5-mm single amplitude, 10 minutes
each in three directions
Shock
resis-
tance
Destruc-
tion 300 m/s2 3 times each in 6 directions
Malfunc-
tion 200 m/s2 3 times each in 6 directions
Weight Approx. 250 g (Counter only)
Safety standards UL508 (See note.)/CSA C22.2 No.14
EN61326
EMC
(EMI) EN61326
Emission Enclosure: EN61326 (EN55011 Group 1 Class A)
Emission AC Mains: EN61326 (EN55011 Group 1 Class A)
(EMS) EN61326
Immunity ESD: EN61326 (EN61000-4-2): Contact discharge: 4 kV, air discharge: 8 kV
Radiated electromagnetic field immunity: EN61326 (EN61000-4-3): 10 V/m (Amplitude modulated, 80 MHz to 1 GHz, 1,400 to 2,000 MHz)
10 V/m (Pulse-modulated, 900 MHz ±5 MHz)
Immunity Burst: EN61326 (EN61000-4-4): 2 kV power-line, 1 kV I/O signal-line
Immunity Surge: EN61326 (EN61000-4-5): 1 kV line to line (power line), 2 kV line to ground (power line)
Immunity Conducted Disturbance: EN61326 (EN61000-4-6): 10 V (0.15 to 80 MHz)
H8BM-R
3
Connections
Internal Connections
I/O Functions
Inputs
Outputs
Note: The input and output signals are enabled when power is applied to the Counter. During a power failure, the input signals are disabled, and the output signals are
turned OFF.
Count 9 inputs
Input count values.
Used as time count input signal when timer is used.
Max. counting speed receivable: Count inputs 1 to 7: 30 Hz (Min. signal input width: 16.7 ms), Count inputs 8 and 9: 30 Hz/500 Hz
(Min. signal input width: 16.7 ms/1 ms)
Reset 1 input
Resets count/time value of a displayed Counter No.
Counter under reset does not operate as its output is turned OFF.
Reset signal input received while re-monitor function is ON restores reset count/time value of the specified counter.
While reset signal is ON, RESET indicator lights.
Short When the short input is ON, an input is also received for one of the count inputs 2 to 9 when an input is received for count input 1. The
H8BM can thus be used as a multi-stage preset counter without performing external short-circuit wiring.
Counter No. selection Specifies counter whose count/time value is to be displayed.
I/O inhibit
Inhibits count inputs of all counters.
Turns OFF all forecast outputs, RUN outputs, and machine stoppage outputs.
While I/O inhibit signal is ON, INHB indicator lights.
Forecast 9 outputs
Each of these outputs turns ON when its forecast value has been reached.
When a total counter is used, output one-shot signals as carry signals.
Retain outputs until count values are reset.
RUN 1 output Turns ON when Counter is operating normally.
Machine stoppage
1 output (Common)
Turns ON when count value of one counter has reached set machine stoppage value.
Retains output until count value is reset.
Count input 1
Count input 2
Count input 3
Count input 4
Count input 5
Count input 6
Count input 7
Count input 8
Count input 9
Counter No. selection
Reset input
I/O inhibit input
Short input
Input COM
OR
16 to 26.4 VDC
Forecast output 1
Forecast output 2
Forecast output 3
Forecast output 4
Forecast output 5
Forecast output 6
Forecast output 7
Forecast output 8
Forecast output 9
Machine
stoppage output
RUN output
Output COM
+24 V
0 V(24 VDC
+10%
15%
)
24
25
26
27
28
17
18
19
20
23
22
16
15
21
10
11
12
13
14
3
4
5
6
9
8
7
2
1
OR
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
H8BM-R
Note 1. H8BM-RAD/-RBD outputs the forecast and machine stoppage values simultaneously.
2. The I/O terminals are used for both PNP and NPN. There is no polarity.
Note 1. When the load is short-circuited, the internal
circuits may be damaged.
2. Connect a diode to suppress Counter surge when
an inductive load is connected.
RUN, machine stoppage,
forecast 1 to 9
Output method Open collector
Switching capacity 30 VDC max., 100 mA max.
Residual voltage 2 VDC max.
Leakage current 100 μA max.
H8BM-R
4
Terminal Arrangement
I/O Connections
Input Circuits
Note: Although the input terminals are electrically insulated from the internal
circuit, do not conduct an insulation resistance test on these terminals.
Output Circuits
Note: Although the output terminals are electrically insulated from the internal
circuit, do not conduct an insulation resistance test on these terminals.
Example of Input Connections (Solid-state Switches)
Two-wire Sensors
The count input, counter number selection, reset input, I/O inhibit input, and short input signals are input when the two-wire Sensor turns
ON.
22 23 24 25 26 27 28
15 16 17 18 19 20 21
8 9 10 11 12 13 14
1234567
22 23 24 25 26 27 28
Reset input Counter No.
selection Count input 1 Count input 2 Count input 3 Count input 4 Count input 5
15 16 17 18 19 20 21
Short input I/O inhibit input Count input 6 Count input 7 Count input 8 Count input 9 Input COM
8 9 10 11 12 13 14
RUN output Machine stoppage
output Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5
1 2 3 4 5 6 7
Power supply: 0 V Power supply: 24 V Forecast output 6 Forecast output 7 Forecast output 8 Forecast output 9 Output COM
Photocoupler
5 V
1.4 kΩ
430 Ω
1.4 kΩ
INCOM
Input
39 V
Output
OUTCOM
39 V
H8BM-R
All inputs
Two-wire Sensors
IN COM
24 VDC
H8BM-R
All inputs
Two-wire Sensors
IN COM
24 VDC
Note: Use the following two-wire Proximity Sensors:
(1) High-level: transistor ON
Switching capacity: 5 mA min. Residual
voltage: 4 VDC max.
(2) Low-level: transistor OFF
Leakage current: 1.5 mA max.
(3) Operating voltage range:
20.4 to 26.4 VDC
We recommend using OMRON E2E-X@D@-N
Sensors.
Three-wire Sensors
NPN Type PNP Type
Example of Input Connections
(Contact Switches)
*H: Contact ON.
*Use a contact which can adequately switch
13 mA at 30 V.
All inputs
IN COM
Sensor
main
circuit
H8BM-R
All inputs
IN COM
Sensor
main
circuit
H8BM-R
All inputs
IN COM
Sensor
main
circuit
All inputs
IN COM
Sensor
main
circuit
H8BM-R
H8BM-R
All inputs
IN COM
All inputs
IN COM
H8BM-R
H8BM-R
H8BM-R
5
Operating Methods
Timing Charts
1. Counter (3-stage Preset Operation) 2. Timer (3-stage Preset Operation)
3. Total Counter Operation 4. Total Timer Operation
Note: The count will return to 0 when 999999 is exceeded.
When the power supply is turned OFF, the display and outputs will turn OFF, but the current count/time value will be stored in internal memory.
Nomenclature
Note: Models with only 1-stage setting (H8BM-RAD/RBD) are not provided with pre-forecast and machine stoppage output function; only the forecast output function
is provided.
Reset input
Count input
999999
0
Machine
stoppage value
Forecast value
Pre-forecast
value
Pre-forecast
indicator
(no output)
Forecast
output and
indicator
Machine
stoppage output
and indicator
Count value
Reset input
Count input
999999
0
Forecast
output
(indicator) One-shot time: 20 ms
Count value
0.0 h
Reset input
Count input
99999.9 h
Forecast
output
(indicator)
Time value
Control Output Indicator (Red LED):
Control Output Indicator (LCD)
Pre-forecast value: LCD lights
Forecast value: RED LED lights
Machine stoppage value:
Indicator flashes between red and green
and LCD output indicator flashes.
The following indicators light to show that the count value has reached the preset
value and that the output has turned ON.
Time Range Indicator
s: seconds, h: hours
I/O Inhibit Indicator
Indicates that the I/O inhibit input signal is
ON.
Re-monitor Indicator
Indicates that the system is in the re-monitor
function operation.
RESET Indicator
Indicates that the system is resetting.
Key Protection Indicator
Indicates that operation of the keys on
the front panel is disabled.
Counter No. Indicator
Indicates the number of the counter whose
data is currently displayed.
RESET Key
Resets the count value and output signals.
(Any counter whose forecast value is set to
0 is skipped in RUN mode.)
123456789
COUNTER No. Key
Selects the counter in sequence each time
this Selector is pressed:
RUNForecast
Value
Pre-forecast
value
Machine
stoppage value
MODE Key
Selects the mode in sequence each time
this key is pressed: SET Key
Inputs the set or changed data.
0123456789
Up Keys 1 to 6
Each of these keys increments the preset value of
the corresponding digit, each time it is pressed.
Preset Value (7-mm Height)
Indicates the forecast value during RUN operation.
Indicates the set value in each setting mode.
Current Value (10-mm Height)
Indicates the current count
(current time in timer mode).
RUN mode
Forecast value
Pre-forecast value
Machine stoppage value
Set Mode Indicator
OFF
Multiplication Counter Indicator
Indicates that the system is in multiplication
counter function operation.
Initial Setting Mode Indicator
Indicates that the system is in the initial
setting mode.
H8BM-R
6
Dimensions (Unit: mm)
Counter
Counter
Installation
Installation Diagram
To mount the Counter, attach the two supplied brackets to the
left and right sides of the Counter, and securely tighten the
knurled screws on the brackets by hand, keeping the Counter
balanced on the right and left. The performance may not be
satisfactory if the screws are loose or excessively tightened. If
the knurled screws are excessively tightened with pliers or
other tool, damage may result.
M 3×5 screws are used. Select solderless terminals referring
to the figure below.
Panel Cutouts
The panel cutout is as shown below (according to DIN 43700).
The mounting panel thickness must be 1 to 5 mm. Mount the
Counter so that the ambient temperature will not exceed 55°C.
Spacing with Other Devices
Provide enough space around the Counter when mounting it
to ensure a proper working space.
55
72 × 7275
36
9
67.5 × 67.559
11
6
Hard Protective Cover (transparent)
75 64.5
79
85.7
H8BM-R
13.7
75 + α
57.5
αSupplied
mounting
brackets (2)
Hard Protective Cover
(transparent)
Rubber packing Mounting panel Knurled screw
Attach the brackets in
line with the rail guides
(ridges) on the case.
Be sure that there is
no gap between the
brackets and the
knurled screws once
the knurled screws
have been tightened.
3.2 5.8
78 min.
78 min.
68+0.7
0
68+0.7
0
ISO4757
Phillips screwdriver #2
100
80°
Other components
H8BM-R
7
Safety Precautions
Refer to Safety Precautions for All Counters.
Fire may occasionally occur. Tighten terminal screws
securely to a tightening torque of 0.5 to 0.6 N·m.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or
repair the Product or touch the interior of the Product.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal
or conductors or any clippings or cuttings resulting
from installation work to enter the Product.
In order to ensure safe operation, be sure to observe the
following points.
(1) Store the Counter within the specified temperature range. If
the Counter has been stored at a temperature under
10°C, allow the Counter to stand at room temperature for
at least 3 hours before using it.
(2) Use the Counter within the ratings specified for ambient
operating temperature and ambient operating humidity.
(3) Do not operate the Counter in any of the following
locations.
Locations subject to sudden or extreme changes in
temperature.
Locations where high humidity may result in
condensation.
(4) Use the Counter within the specified ratings for vibration
and shock.
(5) Do not use the Counter in locations subject to excessive
dust, corrosive gases, or direct sunlight.
(6) When using the Counter in environments subject to large
amounts of static electricity (e.g., pipes carrying molding
materials, powders, or fluid materials), separate the
Counter as far as possible from the sources of static
electricity.
(7) Use the Counter within the specified ratings for vibration,
shock, water immersion, and exposure to oil.
(8) Always use a thermo-switch on the load circuit when a
heater is used.
(9) Do not use organic solvents (such as paint thinner or
benzene), strong alkalis, or strong acids because they will
damage the external finish of the Counter.
(10) Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly
indicate its function.
(11) Be sure that all terminals are wired correctly.
(12) Do not connect more than two crimp terminals to the same
terminal.
(13) Use the specified wires for wiring.
Applicable Wires
AWG22 to AWG14
(cross-sectional area of 0.326 to 2.081 mm2)
Solid or twisted wires of copper
(14) Always maintain the load current within specifications.
(15) Use a switch, relay, or other contact device to turn OFF the
power supply instantaneously. Outputs may malfunction
and memory errors may occur if the power supply voltage is
decreased gradually.
(16) Up to two wires of the same size and type can be inserted
into a single terminal.
(17) Separate the input devices, input wiring, and Counter as far
as possible from sources of noise and power lines carrying
noise.
(18) The life of internal parts may be reduced if Counters are
mounted in close proximity to each other.
(19) Maintain voltage fluctuations in the power supply within the
specified range.
(20) Use a switch, relay, or other contacts so that the rated
power supply voltage will be reached within 0.1 s. If the
power supply voltage is not reached quickly enough, the
power source may fail to reset or the outputs may fall to
operate correctly.
(21) Do not leave the Counter for long periods at a high
temperature with output current in the ON state. Doing so
may result in the premature deterioration of internal
components (e.g., electrolytic capacitors).
(22) Periodically inspect and replace the rubber packing. It may
deteriorate, expand, shrink, or harden in some operation
environments.
(23) Check that the backlight, output indicators, and LCD are
operating normally. Some operating environments may
accelerate deterioration of the indicators, LCD, and resin
components and cause display malfunctions. Periodically
inspect and replace parts.
(24) Be sure that the voltage applied is within the specified
range; otherwise, the internal elements of the Counter may
be damaged.
(1) Be sure that the capacity of the power supply is sufficient.
The Counter may not start due to the capacity of the power
supply or the inrush current that may flow for an instant
(approx. 1.6 A for 12 ms) when the Counter is turned ON.
(2) The Power Supply, input, and output circuits are electrically
isolated inside the Counter.
When turning the power ON and OFF, input signal
reception is sometimes possible, sometimes not possible,
and sometimes unstable, as shown in the diagram below.
Turn on or off the operating power source all at once by
using switch or relay contact.
(3) EEPROM is used to back up the memory if the power fails.
Data can be written to EEPROM 100,000 times. Data is
written to the EEPROM when the settings are changed or
deleted or the power is turned OFF.
(4) The Counter uses a constant read-in system, so outputs
will turn ON if the set values are changed during operation
such that the set value is equal to or less than the count
value.
(5) Dispose of the Counter in accordance with all local
industrial waste disposal procedures.
(6) The water and oil resistance will be lost if the front sheet is
peeled off or torn.
Do not use the Counter if the front sheet is peeled or torn.
CAUTION
Precautions for Safe Use
Precautions for Correct Use
Input signal reception Impossible
200 ms 10 ms
0 to 100 ms 0 to 900 ms
Possible
Un-
stable Unstable Impossible
Power supply ON
OFF
H8BM-R
8
Operation
Key protection and whether each counter operates as a counter or a timer are specified on a DIP switch provided on the side panel of the
Counter. Open the cover of the switch compartment on the side of the Counter to access the DIP switch.
The system will always enter the RUN mode after the power supply is turned ON.
1. DIP Switch Settings
54321 6 7 89 10
Timer
Counter
Enabled
Disabled
Key Protection
(Can always be switched.)
DIP switch compartment
Note 1. Set the DIP switch (except for Key Protection) before turning
ON the power.
Changes to DIP switch settings while the Counter is operating
will be ignored. Power must be turned OFF then back ON
after changing the settings.
Changes to DIP switch settings are also enabled when
changing to initial setting mode because the same operation
is performed as when cycling the power.
2. Key protection can be set for each key. Key protection will be
performed based on the details set in the initial setting mode.
Refer to Initial Setting Mode on page 11.
2. Changing Mode
MODE
Key
MODE
MODE
Key
MODE
Key
MODE
Key
Key
Re-monitor mode
Refer to page 11 for
information on the initial
setting mode.
--
23456
3
200000
23456
3
200000
23456
3
500
23456
3
10000
Normal Mode
Key
Press for 4 s min. Press for 4 s min.
This mode is for the operational state.
The present value, set value, counter number,
and output status will be displayed.
This mode is for setting forecast values.
Values can be independently set for each
counter number.
This mode is for setting pre-forecast values.
The pre-forecast will be displayed (LCD) as a value before
the forecast value. Set that value as the pre-forecast value.
Values can be independently set for each counter number.
Set the pre-forecast value by deviation.
RUN mode
Forecast value mode
Pre-forecast value mode*
Machine stoppage mode*
Initial Setting Mode
SET
Refer to page 12 for
information on the
re-monitor mode.
This mode is for setting machine stoppage values.
Machine stoppage (output/LCD) will occur at a value in
excess of the forecast value. Set that value as the
machine stoppage value.
Values can be independently set for each counter number,
but machine stoppage output will be performed if any
counter from No. 1 to 9 reaches the machine stoppage
value.
Set the machine stoppage value by deviation.
Note: I/O operations are always performed regardless
of the mode.
If no key is pressed for 1 minute in each mode,
the RUN mode is automatically restored.
will flash.
The modes marked * are not provided on the 1-
stage type Counter.
3
H8BM-R
9
Setting/Changing Forecast Value
1. In the RUN mode, press the
Key to enter the forecast
value setting mode.
The same counter number as in the RUN
mode is displayed after changing to
forecast value mode.
2. Press the Key (or turn ON
the counter number selection
input) to select the counter whose
data is to be set or changed.
The counters are selected in sequence
each time the Key is pressed, from
1 through 9, then back to 1.
A counter can also be selected by inputting the counter number selection
input.
3. Use the Keys ( ) to
change the values of the digits.
When an Key is pressed, the
corresponding digit starts flashing.
The preset value is zero-suppressed. Each
time the Key is pressed, the value
changes in sequence,
from 1234567890.
In the following example, the forecast
value of counter 2 is set to 35000.
4. Press the Key to enter the
set value.
If no key is pressed within 5 seconds after
the Key has been pressed, RUN
mode is automatically restored.
(The display is changed automatically
after the set forecast value has
flashed.)
Setting and Changing Pre-forecast Values (3-stage
Type)
1. Press the Key to enter the
pre-forecast value setting mode.
The same counter number as in the
forecast value setting mode is displayed
after changing to pre-forecast value mode.
“-” is automatically displayed.
2. Press the Key (or turn ON
the counter number selection
input) to select the counter whose
data is to be set or changed.
Next, press the Key
( ) to set or change the pre-
forecast value.
The Key does not need to be pressed if the counter does not need to
be changed.
3. Press the Key to enter the
set value.
If no key is pressed within 5 seconds after
the Key has been pressed, the
RUN mode is automatically restored.
Setting and Changing the Machine Stoppage Value (3-
stage Type)
1. Press the Key to enter the
Machine Stoppage Value setting
mode.
The same counter number as in the pre-
forecast value setting mode is displayed
after changing to machine stoppage value
setting mode.
“+” is automatically displayed.
2. Press the Key (or turn ON
the counter number selection input)
to select the counter whose data is
to be set or changed.
Next, press the Key
( ) to set or change the
machine stoppage value.
The Key does not need to be pressed if the counter does not need to
be changed.
3. Press the Key to enter the
set value.
If no key is pressed within 5 seconds after
the Key has been pressed, the
RUN mode is automatically restored.
3. Setting/Changing Data
0
1
100000
MODE
0
2
0
CNT No.
CNT No.
123456789
0
2
10000
0
2
35000
UP
1 6
to
UP
UP
1234567890
0
2
35000
SET
SET
0
2
35000
0
2
0
--
MODE
0
2
1000
--
CNT No.
UP
1 5
to
CNT No.
0
1
1000
--
SET
SET
0
2
0
MODE
0
2
2500
CNT No.
UP
1 5
to
CNT No.
0
2
2500
SET
SET
H8BM-R
10
Setting Counters That Will Not Use the Machine
Stoppage Output (3-stage Type)
The machine stoppage output will not be
used for counters for which the machine
stoppage value has been set to +99999
(+9999.9 h/+9999.9 s).
Setting Counters That Will Not Be Used
Input and output operations will not
occur for counters for which the forecast
value has been set to 0 (0.0 h/0.0 s).
If the forecast value is set to 0 (0.0 h/0.0 s), the
pre-forecast and machine stoppage values will
automatically be set to 0 (0.0 h/0.0 s).
Setting Counters to Be Used as Total Counters/Timers
Counters can be used as total counters/
timers if the forecast value for that
counter is set to 999999 (99999.9 h/
99999.9 s).
The machine stoppage output will no longer be
output for that counter.
When using a counter as a total counter, the
forecast output for that counter when the count
value changes from 999999 to 0 will be a one-
shot output of 20 ms to indicate a carry.
Press the Key (or turn ON the
counter No. selection input) in RUN
mode to check the count value for each
counter.
The counter number changes in sequence
each time the Key is pressed (or the input turns ON), from 1 through
9, then back to 1.
Note: However, any counter whose forecast value is set to 0 (0.0 h/0.0 s) will be
skipped.
Timer Operation Display
The period on the count value display
will flash while the count input is ON and
the Timer is in h mode.
The timer operation measures time by totaling
the ON time of the count input.
1. Resetting Individual Counters
(1)Press the Key (or turn ON the
counter number selection input) to
select the counter to be reset.
The counter value can be reset in all modes
except initial setting mode and re-monitor
mode.
(2)Press the Key (or turn ON
the reset input) to reset the count
value to 0 for that counter only.
2. Resetting of All Counters at the Same Time
Press and hold both the and
Keys for 3 seconds to reset the
count value for all counters to 0.
The same operation is achieved by
simultaneously turning ON the counter number
selection and reset inputs for 3 seconds.
Press and hold the and
Keys for 3 seconds to reset the count
values, pre-forecast values, forecast
values, and machine stoppage values to
0 for all counters.
The counter number after All Clear has been
executed will automatically change to 1.
The pre-forecast value, forecast, and machine stoppage status
display will be as follows:
Pre-forecast Values (3-stage
Type)
The output display for counters for
which the count value has reached the
pre-forecast set value will be lit.
Pre-forecast values are only displayed as a
message and are not output.
Forecast Outputs
A red indicator will light at the top of the
output display section for the lit counter
number and the output will turn ON.
Machine Stoppage Output (3-
stage Type)
The entire background will alternate
between red and green and the
output display for the counter with a
machine stoppage will flash.
Note: If the pre-forecast, forecast, or machine
stoppage output turns ON, the counter
number display will automatically change
to that number and the count value will be
displayed (in RUN mode only).
4. Special Set Values
5. Checking Count Values (RUN Mode)
6. Other Indicators
0
7
99999
00
7
99999
0
9
0
0
8
999999
9000
1
100000
CNT No.
CNT No.
123456789
00
1
10000
7. Deleting Count Value
8. All Clear
9. Control Output Display
100000
8
100000
CNT No.
0
8
100000
RESET
0
a
100000
CNT No.
RESET
23456
3
200000
0
1
0
RESET
SET
90000
1
100000
100000
1
100000
110000
1
100000
H8BM-R
11
This mode is for setting a number of convenient functions.
10. Initial Setting Mode
23456
3
200000
count
30h
MODE
ti rng
1
01
MODE
short
9
MODE
eset
on
MODE
ode
off
MODE
set
off
MODE
ult
off
MULTI
MODE
Normal
Mode
Press for 4 s min.
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
Initial
Setting
Mode
1. Max. Counting Speed
Switching
2. Time Rages
3. Short Function
4. RESET Key Protection
Mode
5. MODE Key Protection
Mode
6. SET Key Protection
Mode
7. Multiplication Counter
Refer to page 8 for the normal modes.
If the mode is switched to the initial setting mode during operation,
operation will continue.
The characters displayed in reverse video are the default settings.
Counter 1 inputs can be input to other counters.
ex. if “5” is selected, Counter 1 inputs can be input to counters 2 to 5.
Press the Key and select the number of counters for which the short
function is to be enabled.
Press the Key to enter the setting.
Note: The short input is read only when the power is turned ON. They are ignored if
input during operation.
UP
OFF2345678
9
SET
The RESET Key can be protected.
Press the Key and select the counter for which RESET Key protection is
to be set.
Press the Key to enter the setting.
Note 1. The Reset of All Counters and All Clear using the RESET Key are disabled
if the RESET Key Protection function is turned ON.
2. Key Protection function is activated by setting the Dip Switch to 10.
UP
ON (ch1 to 9) ON (ch8/9) ON (ch9) OFF
SET
The max. counting speed switching for counters 8 and 9 can be
changed.
Press the Key to switch between and 500 Hz.
Press the Key to enter the set value.
UP
30 Hz
SET
The Timer time rages can be changed.
Press the Key to change the time rages.
Select the counter number.
Press the Key to switch between and 0.1 s.
Press the Key to enter the set value.
Note: The time unit is displayed when the counter is set to a timer on the DIP switch.
CNT No.
UP
0.1 h
SET
The MODE Key can be protected.
Press the Key to switch between and on.
Press the Key to enter the setting.
Note: Key Protection function is activated by setting the Dip Switch to 10.
UP
off
SET
The SET Key can be protected.
Press the Key to switch between and on.
Press the Key to enter the setting.
Note: Key Protection function is activated by setting the Dip Switch to 10.
UP
off
SET
Press the Key to switch between and on.
Press the Key to enter the setting.
Note: A Multiplication Counter is a batch counter that increments the count of
counter 9 each time the forecast value of counter 1 is reached.
UP
off
SET
H8BM-R
12
Use this mode to return to the count value before resetting if the
count value is mistakenly reset.
1. In the RUN mode, hold the
Key for 4 seconds min. to change to
re-monitor mode.
The previous values that have been reset
will be displayed.
Only the display changes. Internal counting
operations are not affected.
The counter number remains unchanged on
RUN display when the mode is changed to
re-monitor display.
2. Press the Key
(or turn ON the counter number
selection input) to select the counter
to be re-monitored.
3. When the Key is pressed
(or the reset input turns ON), the
re-monitor value will flash 3 times
and the only the count value for
that counter will be returned to the
value prior to being reset.
The following displays are made when errors occur.
11. Re-monitor Mode
100000
1
100000
SET
23456
3
200000
CNT No.
23456
3
200000
RESET
12. Self-diagnosis Function
Display Error content All I/O Countermeasure
e1 CPU Errors Prohibited
Turn OFF the power or press the
Key to clear the error and
restore the settings and count
values to the values before the
error.
e2 Memory Errors Prohibited
Turn OFF the power or press the
Key to clear the error and
return the count values for all
counters to 0.
e3 Key Errors Prohibited
Turn OFF the power supply or
press the Key to clear key
errors.
RESET
RESET
RESET
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.