Schneider Electric Brand
s
Proximity Sensors
File 9006
CONTENTS
Description Page
Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Auto-adaptable and Standard Flat Inductive Proximity Sensor . . . . . . . . . . . . . . . 206
Auto-adaptable and Standard Cylindrical Inductive Proximity Sensor . . . . . . . . . . 210
Application Specific Flat, Rectangular and Cylindrical . . . . . . . . . . . . . . . . . . . . . . 214
Capacitive Proximity Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Magnet Actuated Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Mechanical Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
Operation and Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
x
Proximity Sensors
Inductive Sensors
Interpretation of Catalog Numbers
©1997- 2002 Schneider Electric All Rights Reserved
198 10/02
Proximity Sensors
Inductive Sensors / Interpretation of Catalog Num bers
I
Proximity Sensors Example XS8C1A1PAL2
Inductive Sensor
TYPE
Cylindrical Optimum 5
Cylindrical Universal 6
Optimum Rectangular 7
Universal Rectangular 8
Application Specific 9
FORMAT OR MODE
Rectangular 8x8x20 J 1
Rectangular 8x15x32 F 1
Rectangular 13x26x26 E 1
Rectangular 15x40x40 C 1
Rectangular 26x80x80 D 1
Cylindrical smooth 4mm L 4
Cylindrical 5mm 0 5
Cylindrical smooth 6mm L 6
Cylindrical 8mm 0 8
Cylindrical 12mm 1 2
Cylindrical 18mm 1 8
Cylindrical 30mm 3 0
FAMILY TYPE OR MATERIAL
Applications 1...9
Plastic A
Metal B
Stainless Steel S
APPLICATION
Operating Mode 1...9
Food & Beverage A
Namur E
Ferrous only F
Light industry L
Ferrous/Non-ferrous M
Non-ferrous only N
Speed Control R
Serdac S
Weld Field Immune W
OUTPUTS
DC 3 wire PNP P
DC 3 wire NPN N
DC 3 wire PNP/NPN K
DC 2 wire (3/4) D
DC 2 wire automobile (1/4) C
DC analog output A
AC 2 wire F
AC/DC 2 wire M
AC/DC 2 wire SCP protect S
AC/DC relay output R
BUS B
FUNCTION
Analog 0. . .10mA 1
Analog 4.20mA 2
N.O. A
N.C. B
N.O. + N.C. C
Programmable/wiring P
Programmable S
CABLING OR CONNECTION
M8X1 Nano (S) M 8
M12x1 Micro (D) M 1 2
7/8 16UN Mini (A) U 7 8
1/2 20 UNF Micro (K) U 2 0
Cable 0.1m L01
Cable 2m L 2
Cable 5m L 5
Cable 10m L10
M12 micro on0.1m pigtail L 0 1 M 1 2
PG 16 cable gland T 1 6
Proximity Sensors
Inductive Sensors
Interpretation of Catalog Numbers
199
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
PROXIMITY Tubular Inductive Sensors / Interpretation of Catalog Numbers
.
NOTE: This table is intended to understand catalog number designations. It is NOT to be used to create numbers which may not exist. Consult your local field office
Rectangular Example XS7C40PC440R30H*
SENSOR TYPE
Self Contained X
Component Z
SENSING TECHNOLOGY
Inductive Proximity S
Capacitive Proximity T
BODY STYLE
Miniature 5
Shielded 7
Non-Shielded 8
Block Style D
FAMILY TYPE
Limit Switch Style - Plastic Body C
Compact Block G
Sub Compact Block H
Miniature L
Cubic T
MANUFACTURING CODES
OUTPUT TYPE
NPN N P
PNP P P
AC/DC Universal M A
2 wire N.O./N.C. D P
NPN N.O.+N.C. N C
PNP N.O.+N.C. P C
MANUFACTURING CODES
SUFFIX
2 Meter Cable or Conduit Opening Blank
Micro Connector -- DC D
Alternate Frequency F
Micro Connector -- AC/DC K
5 Meter Cable L2
10 Meter Cable L10
Mini Connector, Normally Open R30
Mini Connector, Normally Closed R31
Nano Connector -- DC S
Bulk Pack TQ
* H suffix, which MAY appear on device or carton label, is for manufacturing purposes only. It designates compliance with specific national standards. EX: H7 = UL and CSA approval, 0.5"
conduit opening (where applicable). H suffixes should not be used when ordering (except when non US standards are required)
Tubular Example XS1M18PA370D
SENSOR TYPE
Self Contained X
SENSING TECHNOLOGY
Inductive Proximity S
Capacitive Proximity T
BODY TYPE
Shielded -- Metal Body 1
Non-shielded -- Metal Body 2
Non-shielded -- Plastic Body 4
TYPE OF ENCLOSURE OR FAMILY
Economy D D
Standard Length -- Threaded Metal CaseM M
Short Length -- Threaded Metal CaseN N
Unthreaded Metal CaseL L
Threaded Plastic CaseP P
BARREL DIAMETER
4mm Diameter 0 4
5mm Diameter 0 5
6mm Diameter 0 6
8mm Diameter 0 8
12mm Diameter 1 2
18mm Diameter 1 8
30mm Diameter 3 0
32mm Diameter 3 2
MODEL TYPE
Analog AB
DC PNP P
DC NPN N
DC PNP/NPN, N.O./N.C. (Selectable) K
DC 2 Wire D
AC/DC 2 Wire (Universal) M
OUTPUT MODE
N.O. (Normally Open) A
N.C. (Normally Closed) B
N.O. + N.C. Complementary C
N.O. or N.C. Selectable P
MANUFACTURING CODES •••
CONNECTORS
Nano (M8) DC OnlyS S
Micro DC OnlyD D
Micro AC OnlyK K
Mini AC or DCA A
Micro DC PigtailLD LD
Mini AC or DC PigtailLA LA
EXTENDED CABLE LENGTH
5 Meter CableL1 L1
10 Meter CableL2 L2
Proximity Sensors
Selection Guide
Rectangular
©1997- 2002 Schneider Electric All Rights Reserved
200 10/02
Proximity Sensors
Selection Gu ide / Rectangular
Description Plastic Shielded Fixed and Adjustable sensing Range
Fixed Sensing Range Auto Adaptable Adjustable Sensing Range
XS7 XS8
Size / Dimensions
H x W x D (mm)
J
22x8x8
F
32x15x8
E
26x26x13
C
40x40x15
D
80x80x26
E
26x26x13
C
40x40x15
D
80x80x26
Nominal Sensing Distance
Sn (mm) 2.5 5 10 15 40 15 25 60
Supply (Voltage Limits)
DC 3 wire 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V
Maximum Load 100 mA 100 mA 100 mA 100 mA 100 mA 100 mA 200 mA 200 mA
DC 2 wire 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V
Maximum Load 100 mA 100 mA 100 mA 100 mA 100 mA
AC/DC 2 wire 20 - 264 V 20 - 264 V 20 - 264 V
Maximum Load 200 mA 300 mA 300 mA
Enclosure Rating
Cable Version IP68 IP68 IP68 IP68 IP68 IP68 IP68 IP68
Connector Version IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Connection
Cable 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’)
Connector M8 M8 M8/M12 M8/M12 M12 M8/M12/ U20 M8/M12/ U20 M12/U20
Temperature Rating -13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
Page Number 208 208 208 208 208 206 206 206
Description Plastic Classic Rectangular Shielded & Non-shielded
Miniature Compact
XS5L XSB; XS7,8H; XS7,8G; XS7,8T
Size (mm) 8x43 50x76 10x28 26x40 26x26 40x40
Nominal Sensing Distance
Shielded Sn (mm) 1.5 2 2 10 15
Nominal Sensing Distance
Non-shielded Sn (mm) –25341520
Supply (Voltage Limits)
DC 3 wire 10 – 30 V 10 – 30 V 10 – 30 V 10 – 58 V 10 – 58 V
Maximum Load 100 mA 200 mA 200 mA 200 mA 200 mA
DC 2 wire 12 – 58 V 10 – 58 V 10 –58 V
Maximum Load 80 mA 100mA 100mA
DC 4 wire 10 –58 V 10 – 58 V 10 – 58 V
Maximum Load 200 mA 200 mA 200 mA
AC 2 wire 93 – 264 V
Maximum Load 150 mA
AC/DC 2 wire 20 –264 V
Maximum Load 200 mA
Dimension
(mm)
Cable 43x8x8 28x10x16 40x12x26 26x26x26 40x40x40
Connector 49x8x8 76x50x41 45x12x31 26x26x29 40x40x44
Enclosure Rating
Cable Version IP67 IP67 IP67 IP67 IP67
Connector Version IP67 IP67 IP67 IP67 IP67
Connection
Cable 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’)
Connector M8 U78 M8 M12 M12
Temperature Rating -13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
Page Number 266 272 268 270 274 274
Proximity Sensors
Selection Guide
Rectangular and Application Specific
201
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Selection Guide / Rectangular and Appl ication Specific
Description Plastic Classic Rectangular Shielded & Unshielded
Limit switch style Long Range Block
XS7/8C XS8 IQ Prox XSD
Dimension (mm) 117x40x40 117x40x40 100x80x40 100x80x40
Nominal Sensing Distance
Shielded Sn (mm) 15 25 40
Nominal Sensing Distance
Non-shielded Sn (mm) 20 25 50 30 - 60
Supply (Voltage Limits)
DC 3 wire 10 – 58 V 19 – 30 V
Maximum Load 200 mA 200 mA
DC 2 wire 10 – 58 V 10 – 58 V 10 – 58 V
Maximum Load 100 mA 100 mA 100 mA
DC 4 wire 10 – 58 V 10 – 58 V 10 – 58 V
Maximum Load 200 mA 200 mA 200 mA
AC 2 wire 20 – 264 V 20 – 264 V 20 – 264 V
Maximum Load 350 mA 500 mA 500 mA
AC/DC 2 wire 20 – 264 V
Maximum Load 200 mA
Enclosure Rating
Conduit Version IP67 IP67 IP67 IP67
Connection
Conduit 1/2" NPT 1/2"NPT 1/2" NPT 1/2" NPT
Temperature Rating -13°F to +158°F
(-25°C to +70°C
-13°F to +158°F
(-25°C to +70°C
-13°F to +158°F
(-25°C to +70°C
-13°F to +158°F
(-25°C to +70°C
Page Number 276 278 280 282
Description Cylindrical, Rectangular Application Specific
Selective F,NF, N&NF WFI Namur Analog Capacitive Magnet Actuated Rotation Control
Size (mm) 18, 30mm Limit Switch 12, 18mm
Compact Block Style
4, 5, 6.5, 8, 12, 18,
30mm Block Style
12, 18, 30mm,
F,E,C,D Limit switch
12, 18, 30, 32mm,
Limit switch
Compact Block Style
Tubular Style
30mm
E, C
Nominal Sensing Distance
Shielded Sn (mm)
Max. Sn shown
5 - 40 2 -10 0.8 - 40 2 - 60 2 - 15 10 -15
Supply (Voltage Limits)
DC 3 wire 10 – 38 V 10 – 36 V 24 V / 48 V 10 – 38 V 10 – 58 V
Maximum Load 200 mA 250 mA 300 mA 200 mA
DC 4 wire 10 38 V––––––
Maximum Load 200 mA ––––
DC 2 wire 10 –58 V 7 –12 V 24 V /48 V 200 V
Maximum Load 100 mA 1.65 mA 0.5 A
AC 2 wire 93 –132 V 20 –264 V 120 –240 V
Maximum Load 150 mA 350 mA 0.5 A
AC/DC 2 wire 20 – 264 V 130 -200 V 20 –264 V
Maximum Load 300 mA –––0.5 A0.35 A
Enclosure Rating
Cable Version IP68 IP67 IP64/IP67 IP67 IP63/IP67 IP67 IP67
Connector Version IP67 IP67 IP67 IP67 IP67
Conduit Entry IP67 IP67 IP67 IP67
Temperature Rating -13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-13°F to +158°F
(-25°C to +70°C)
-40°F to +140°F
(-40°C to +60°C)
-13°F to +158°F
(-25°C to +70°C)
Page Number 260 286 290 214, 292 294 302 216, 284
Proximity Sensors
Selection Guide
Cylindrical
©1997- 2002 Schneider Electric All Rights Reserved
202 10/02
Proximity Sensors
Selection Guide / Cylindrical
Description Metal Fully Shielded Fixed Sensing Range Metal Fully Shielded/Non-Shielded
Standard Sensing Range Extended Sensing Range Auto Adaptable Adjustable Range
XS5 XS6 XS6
Diameter (mm) 8 12 18 30 8 12 18 30 12 18 30
Nominal Sensing Distance
Sn (mm) 1.5 2 5 10 2.5 4 8 15 4 8 15
Supply (Voltage Limits)
DC 3 wire 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 58 V 10 - 58 V 10 – 58 V 10 - 58 V 10 – 36 V 10 – 36 V 10 – 36 V
Maximum Load 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 100 mA 100 mA 100 mA
Dimension
(mm)
Cable M8x33 M12x33 M18x36.5 M30x40.6 M8x50 M12x50 M18x60 M18x60
Connector M8x42 M12x48 M18x48.6 M30x50.7 M8x61 M12x61 M18x72.2 M30x72.2 M12x50 M18x60 M30x60
DC 2 wire 10 - 58 V 10 - 58 V 10 - 58 V 10 - 58 V
Maximum Load 100 mA 100 mA 100 mA 100 mA
Dimension
(mm)
Cable M8x50 M12x50 M18x52.5 M30x50
Connector M8x61 M12x61 M18x64.6 M30x64.2
DC 4 wire –––––
Maximum Load
Dimension
(mm)
Cable–––––
Connector
AC/DC 2 wire 20 - 264 V 20 - 264 V 20 - 264 V
Maximum Load 100 mA 100 mA 100 mA
Dimension
(mm)
Cable M12x50 M18x60 M30x60
Connector M12x61 M18x72.2 M30x72.2
Enclosure Rating
Cable IP67 IP68 IP68 IP68 IP67 IP68 IP68 IP68
Connector IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Connection
Cable Version 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’)
Connector Version M8 M12 M12 M12 M8 M12/U20 M12/U20 M12/U20
Operating Temperature Rating
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
Page Number 212 212 212 212 210 210 210 210 210 210 210
Proximity Sensors
Selection Guide
Cylindrical
203
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Selection Guide / Cylindrical
Description Plastic Unshielded Metal Shielded/Non-Shielded Fixed Sensing Range
Standard Sensing Range Standard Sensing Range (Classic) Nominal Range, Miniature
XS4.P XS1, 2M (N) XS1, 2 L(N)
Diameter (mm) 8 12 18 30 8 12 18 30 4 5 6.5
Nominal Sensing Distance
Shielded Sn (mm) ––––1.52510111.5
Nominal Sensing Distance
Unshielded Sn (mm) 2.548152.54815––2.5
Supply (Voltage Limits)
DC 3 wire 10 – 38 V 10 – 38 V 10 – 38 V 10 – 38 V 10 –58 V 10 –58 V 10 –58 V 10 –58 V 5 –30 V 5 – 30 V 10 – 38 V
Maximum Load 200 mA 200 mA 200 mA 200 mA 100 mA 200 mA 200 mA 200 mA 100 mA 100 mA 200 mA
Dimension
(mm)
Cable M8x33 M12x33 M18x33 M30x40 M8x50 M12x50 M18x60 M30x60 M4x29 M5x29 M6.5x33
Connector M8x45 M12x45 M18x45 M30x50 M8x61 M12x61 M18x70 M30x70 M4x41 M5x41 M6.5x45
DC 2 wire ––––1058 V10 –58 V 10 –58 V 10 –58 V
Maximum Load ––––100 mA100 mA100 mA100 mA–––
Dimension
(mm)
Cable–––––––––––
Connector–––––––––––
DC 4 wire 10 38 V10 38 V10 38 V10 38 V––––––10 38 V
Maximum Load 200 mA 200 mA 200 mA 200 mA ––––––200 mA
Dimension
(mm)
CableM8x50M12x50M18x60M30x60––––––M6.5x50
ConnectorM8x61M12x61M18x70M30x70–––––––
AC/DC 2 wire 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V
Maximum Load 100 mA 200 mA 200 mA 200 mA 100 mA 200 mA 200 mA 200 mA
Dimension
(mm)
Cable M8x50 M12x50 M18x60 M30x60 2 m(6.6’) 2 m(6.6’) 2 m(6.6’) 2 m(6.6’)
Connector M8x61 M12x61 M18x70 M30x70 U20 U20 U20/U78 U20/U78
Enclosure Rating
Cable IP67IP68IP68IP68IP67IP68IP68IP68IP67IP67IP67
Connector IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Connection
Cable 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’) 2 m (6.6’)
Connector M8 / U20 M12/U20 M12/U20 M12/U20 M12/U20 M12/U20 M12/U20 M12/U20 M8 M8 M8/M12
Operating Temperature Rating
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+176°F
(-25°C to
+80°C)
-13°F to
+176°F
(-25°C to
+80°C)
-13°F to
+176°F
(-25°C to
+80°C)
-13°F to
+176°F
(-25°C to
+80°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
-13°F to
+158°F
(-25°C to
+70°C)
Page Number 226 236 240 248 224 232 240 248 218 220 222
OSICONCEPT Proximity Sensors
XS Inductive Sensors
Auto-Adapable Technology
© 1997-2002 Schneider Electric All Rights Reserved
204 10/02
Proximity Sensors
XS Inductive Sensors - Auto-Adapable Technology
Principle of Operation
Osiconcept, Auto-Adaptable Technology is a patented innovation that offers simplified selection
and installation.
Sensor can be flush mounted, non-flush mounted or recessed mounted. A metal background
can be placed in immediate proximity of the sensor.
To set-up, activate adaptable technology by pressing button. When no target is present, the
sensor will adapt to the environment, then pass the target in front of the sensor in the usual
way. The green LED flashes when sensor is adapting to its environment or learning target
location, then becomes steady when sensor is set. After the sensor is programmed it will
recognize the target and provide output.
NOTE: Follow instruction bulletin provided with Osiconcept Auto-Adaptable product.
Fine Adjustment for Precise Positioning
The simple process of pressing the self-teach button with the target located in the precise
position (lateral movement) across the detector sensing face. This adjustment will only allow
the sensor output to change state when the object reaches the precise position in the sensors
field.
The simple process of pressing the self-teach button with the target located in the precise
position (frontal distance) from the detector sensing face. This adjustment will only allow the
sensor output to change state when the object reaches the precise position in the sensors field.
Installation
A full line of support brackets allows for simple and fast installation or maintenance. No tools
are necessary, simple clips and the sensor is fixed in position and ready for operation. Brackets
available for all sizes J, F, E, C, D in flat and 90°.
Brackets available for substitution to existing XSE, XSC, and XSD, see page 300.
OK
GR
=
Sn max.
OK
GR
=
Sn max.
OK
GR
=
Sn max.
Sn Sn Sn
Sn Sn Sn
Fine Adjustment for
Precise Positiong
Fine Adjustment for
Frontal Target Motion
OSICONCEPT Proximity Sensors
XS Inductive Sensors
Auto-Adapable Technology
205
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductiv e Sensors - Auto-Adaptabl e Technology
Flat
Dimensions " (mm) 0.51 x 1.0 x 1.0 (13 x 26 x 26) 1.57 x 1.57 x 0.59 (40 x 40 x 15) 3.14 x 3.14 x 1.0 (80 x 80 x 26)
Size E Size C Size D
Applications Machine Tooling, Molding, Welding Machinery, and Packaging Material Handling, Conveyors
Sn - Flush Mounted " (mm) 0.2-0.39 (5-10) 0.31-0.59 (8-15) 0.78-1.57 (20-40)
Sn - Non-Flush Mounted " (mm) 0.2-0.59 (5-15) 0.31-0.98 (8-25) 0.78-2.36 (20-60)
Product Reference XS8E1A1 XS8CE1A1 XS8D1A1
Pages 206 206 206
Cylindrical
Dimensions " (mm) 0.47 (12) 0.7 (18) 1.18 (30)
Applications Machining, Food Industry
Sn - Flush Mounted " (mm) 0.07-0.13 (1.7-3.4) 6.14-0.27 (3.5-7) 0.24-0.47 (6-12)
Sn - Non-Flush Mounted " (mm) 0.07-0.20 (1.7-5) 0.14-0.40 (3.5-10) 0.24-0.71 (6-18)
Product Reference XS612BkXS618BkXS630Bk
Pages 210 210 210
OSICONCEPT Proximity Sensors
XS8 Auto-Adaptable Inductive Sensor
Flat Rectangular, DC and AC/DC
© 1997-2002 Schneider Electric All Rights Reserved
206 10/02
Proximity Sensors
XS8 Auto-Adaptable Inductive Senso r / Flat Rectangular, DC and AC/DC
Features:
Enhanced sensing distances
Self-adapting to flush or non-flush mounted environments
3 wire DC and 2 wire AC/DC
•Self-teach
aTo order a normally closed (N.C.) version change the A to B, example: XS8C1A1PAL2 to XS8C1A1PBL2.
q5m cable length available with L5 suffix / 10m cable length available with L10 suffix.
Nominal Sensing
Distance
Circuit
Type
Output
Mode
Voltage
Range
Load Current
Maximum
Operating
Frequency Catalog Number
DC
Size E (13x26x26 mm) 2 m (6.6") cable q
15mm PNP N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1PAL2
15mm NPN N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1NAL2
Size E (13x26x26 mm) M8 connector
15mm PNP N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1PAM8
15mm NPN N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1NAM8
Size E (13x26x26 mm) M12 pigtail, 0.1 m
15mm PNP N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1PAL01M12
15mm NPN N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1NAL01M12
Size C (15x40x40 mm) 2 m (6.6’) cable q
25mm PNP N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1PAL2
25mm NPN N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1NAL2
Size C (15x40x40 mm) M8 connector
25mm PNP N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1PAM8
25mm NPN N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1NAM8
Size C (15x40x40 mm) M12 pigtail, 0.1 m
25mm PNP N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1PAL01M12
25mm NPN N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1NAL01M12
Size D (26x80x80 mm) 2 m (6.6’) cable q
60mm PNP N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1PAL2
60mm NPN N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1NAL2
Size D (26x80x80 mm) M12 connector
60mm PNP N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1PAM12
60mm NPN N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1NAM12
AC
Size E (13x26x26 mm) 2 m (6.6’) cable q
15mm 2 wire N.O.* 24-240 Vac/24-210 Vdc 5 – 200 mA 1000/50 Hz XS8E1A1MAL2
Size E (13x26x26 mm) U20 pigtail, 0.1 m
15mm 2 wire N.O.* 24-240 Vac/24-210 Vdc 5 – 200 mA 1000/50 Hz XS8E1A1MAL01U20
Size C (15x40x40 mm) 2 m (6.6’) cable q
25mm 2 wire N.O.* 24-240 Vac/24-210 Vdc 5 – 300 mA 1000/50 Hz XS8C1A1MAL2
Size C (15x40x40 mm) U20 pigtail, 0.1 m
25mm 2 wire N.O.* 24-240 Vac/24-210 Vdc 5 – 300 mA 1000/50 Hz XS8C1A1MAL01U20
Size D (26x80x80 mm) 2 m (6.6’) cable q
60mm 2 wire N.O.* 24-240 Vac/24-210 Vdc 5 – 300 mA 100/50 Hz XS8D1A1MAL2
Size D (26x80x80 mm) U20 connector
60mm 2 wire N.O.* 24-240 Vac/24-210 Vdc 5 – 300 mA 100/50 Hz XS8D1A1MAU20
Minimum Mounting Clearances (mm)
Side by Side Face to Face
XS8E e1.6 (40) e 5.9 (150) e 3.1 (80) e 11.8 (300)
XS8C e2.4 (60) e 4.9 (125) e 4.7 (120) e 9.8 (250)
XS8D e7.9 (200) e 23.6 (600) e 15.7 (400)
501559_1
XS8 1A1••••L2
XS8 E1A1••M8
XS8 E1A1•••M8
XS8 C1A1•••M8
inches (mm)
Dimensions
XS8 C/D XS8E
A
L2
A
M12 BCDEFGH
E0.55
(14)
0.4
(11)
1.0
(26)
0.5
(13)
0.3
(8.8)
0.8
(20)
0.1
(3.5)
0.26
(6.8)
0.25
(6.6)
C0.55
(14)
0.4
(11)
1.6
(40)
0.6
(15)
0.4
(9.8)
1.3
(33)
0.1
(4.5)
0.32
(8.3)
0.53
(13.6
)
D0.9
(23)
0.5
(14)
3.1
(80)
1.0
(26)
0.6
(16)
2.5
(65)
0.2
(5.5)
0.33
(8.5)
1.5
(37.8
)
E
E
C
D
A
B
B
F
G
H
F
B
E
B
ee
OSICONCEPT Proximity Sensors
XS8 Auto-Adaptable Inductive Sensor
Flat Rectangular, DC and AC/DC
207
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS8 Auto-Adaptable Inductive Senso r / Flat Rectangular, DC and AC/DC
Specifications
Mechanical Shielded Non-shielded
Fine Detection Zone
XS8E 5 – 10 mm 5 – 15 mm
XS8C 8 – 15 mm 8 – 25 mm
XS8D 20 – 40 mm 20 – 60 mm
Sn
XS8E 0 – 10 mm 0 – 15 mm
XS8C 0 – 15 mm 0 – 25 mm
XS8D 0 – 40 mm 0 – 60 mm
Temperature Range Storage -40 ° to +185 ° F (-40 ° to +85 ° C)
Operation -13 ° to +158 ° F (-25 ° to +70 ° C)
Enclosure Rating NEMA Type 1, 4X,12
IEC Type IP68 cable version / IP67 connector version
Vibration 25 g, amplitude +/- 2mm (f=10-55 Hz)
Shock Resistance 50 g duration 11ms
Differential (%of Sr) 1 – 15%
Repeatability (% of Sr) 2%
LED Indicator Output Ye l l ow
Power & Teach Green
Enclosure material PBT
Cable PVR 3x0.34mm2
Connector M8 Nano 3pin, M12 Micro 4pin, U20 Micro 3pin
Electrical 2 wire AC/DC 3 wire DC
Voltage Range 24 – 240 Vac/24 - 210 V dc 12 – 24 Vdc
Voltage Limit (including ripple) 20 – 264 Vac/dc 10 – 36 Vdc
Voltage Drop 5.5 V 2 V
Load Current Maximum
XS8E 5. . .200 mA 100 mA
XS8C DC:5. . .300 mA/AC:5. . .260 mA 200 mA
XS8D DC:5. . .300 mA/AC:5. . .260 mA 200 mA
(max.) Leakage (Residual) Current-open state 1.5 mA
Current consumption 10 mA
Power up Delay (max.)
XS8E 10 ms 5 ms
XS8C 10 ms 5 ms
XS8D 15 ms 10 ms
On Delay (max.)
XS8E 0.3 ms 0.3 ms
XS8C 0.3 ms 0.3 ms
XS8D 0.3 ms 0.3 ms
Off Delay (max.)
XS8E 0.7 ms 0.7 ms
XS8C 0.7 ms 0.7 ms
XS8D 5 ms 5 ms
Protective Circuitry Short Circuit Protection No Ye s
Overload Protection No Ye s
Agency Listings
For additional cable options and lengths see p. 518
Connector Cables (M8 or S suffix;
M12 or D suffix; U20 or K suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 9
Wiring
Connector
M8 M12 0.5" 20-UNF
Cable
Blue BU –
Brown BN +
Black BK Output
PNP/M12 or M8
NPN/M12 or M8 Type 2 Wire 0.5" 20-UNF
M8 connector, N.O. and N.C. to to pin 4.
13
4
12
43 1
32
BN/1
BU/3
+
PNP BK/4 (NO)
BK/2 (NC)
BN/1
BU/3
+
BK/4 (NO)
BK/2 (NC)
NPN
BN/2
BU/3
®
Proximity Sensors
XS7 Inductive Sensor
Flat Rectangular, DC
©1997- 2002 Schneider Electric All Rights Reserved
208 10/02
Proximity Sensors
XS7 Inductive Sensor / Flat Rectangular, DC
Features:
Entire range of flat proximity sensors dedicated to OEM’s and their applications.
Complete flat range offering.
2 and 3 wire DC
Normally Open or Normally Closed outputs available
Cable and connector versions
PNP or NPN
aTo order a normally closed (N.C.) version change the A to B, example: XS718B1PAL2 to XS718B1PBL2.
0.8m and 0.15m pigtail length available on 2 wire E and C.
q5m cable length available with L5 suffix / 10m cable length available with L10 suffix.
Nominal Sensing
Distance
Circuit
Type
Output
Mode
Voltage
Range
Load Current
Maximum
Operating
Frequency Catalog Number
Size J (8x8x22 mm) 2 m (6.6’) cable q
2.5 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 4000 Hz XS7J1A1DAL2
2.5 mm PNP N.O.a12-24 Vdc 100 mA 2000 Hz XS7J1A1PAL2
2.5 mm NPN N.O.a12-24 Vdc 100 mA 2000 Hz XS7J1A1NAL2
Size J (8x8x22 mm) M8 pigtail, 0.1 m
2.5 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 4000 Hz XS7J1A1DAL01M8
2.5 mm PNP N.O.a12-24 Vdc 100 mA 2000 Hz XS7J1A1PAL01M8
2.5 mm NPN N.O.a12-24 Vdc 100 mA 2000 Hz XS7J1A1NAL01M8
Size F (8x15x32 mm) 2 m (6.6’) cable q
5 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 5000 Hz XS7F1A1DAL2
5 mm PNP N.O.a12-24 Vdc 100 mA 2000 Hz XS7F1A1PAL2
5 mm NPN N.O.a12-24 Vdc 100 mA 2000 Hz XS7F1A1NAL2
Size F (8x15x32 mm) M8 pigtail, 0.1 m
5 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 5000 Hz XS7F1A1DAL01M8
5 mm PNP N.O.a12-24 Vdc 100 mA 2000 Hz XS7F1A1PAL01M8
5 mm NPN N.O.a12-24 Vdc 100 mA 2000 Hz XS7F1A1NAL01M8
Size E (13x26x26 mm) 2m (6.6’) cable q
10 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 1000 Hz XS7E1A1DAL2
10 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS7E1A1PAL2
10 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS7E1A1NAL2
Size E (13x26x26 mm) M8 connector
10 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 1000 Hz XS7E1A1DAM8
10 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS7E1A1PAM8
10 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS7E1A1NAM8
Size E (13x26x26 mm) M12 pigtail, 0.1 m
10 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 1000 Hz XS7E1A1DAL01M12
10 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS7E1A1PAL01M12
10 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS7E1A1NAL01M12
Size C (15x40x40 mm) 2 m (6.6’) cable q
15 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 1000 Hz XS7C1A1DAL2
15 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS7C1A1PAL2
15 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS7C1A1NAL2
Size C (15x40x40 mm) M8 connector
15 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 1000 Hz XS7C1A1DAM8
15 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS7C1A1PAM8
15 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS7C1A1NAM8
Size C (15x40x40 mm) M12 pigtail, 0.1 m
15 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 1000 Hz XS7C1A1DAL01M12
15 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS7C1A1PAL01M12
15 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS7C1A1NAL01M12
Size D (26x80x80 mm) 2 m (6.6’) cable q
40 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 100 Hz XS7D1A1DAL2
40 mm PNP N.O.a12-24 Vdc 100 mA 100 Hz XS7D1A1PAL2
40 mm NPN N.O.a12-24 Vdc 100 mA 100 Hz XS7D1A1NAL2
Size D (26x80x80 mm) M12 connector
40 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 100 Hz XS7D1A1CAM12
40 mm 2 wire N.O.a12-24 Vdc 1.5 – 100 mA 100 Hz XS7D1A1DAM12
40 mm PNP N.O.a12-24 Vdc 100 mA 100 Hz XS7D1A1PAM12
40 mm NPN N.O.a12-24 Vdc 100 mA 100 Hz XS7D1A1NAM12
501549_1
XS7 FA1••L01M8
XS7 J1A1••L2
XS7 1A1••L2
XS7 D1A1••M12
inches (mm)
Dimensions
XS7 C/D XS7E
A
L2
A
M12 BCD EF
XS7
E
0.55
(14)
0.4
(11)
1.0
(26)
0.5
(13)
0.3
(8.8)
0.8
(20)
0.1
(3.5)
XS7
C
0.55
(14)
0.4
(11)
1.6
(40)
0.6
(15)
0.4
(9.8)
1.3
(33)
0.1
(4.5)
XS7
D
0.9
(23)
0.5
(14)
3.1
(80)
1.0
(26)
0.6
(16)
2.5
(65)
0.2
(5.5)
XS7 F XS7J
B
E
E
C
D
A
B
B
F
E
B
F
B
E
B
0.3
8
1.2 (32)
0.6 (15)
0.3
9
Ø3
0.3
8
0.8 (22)
0.6 (16)
0.3 (8)
4
Ø3Ø4
Dual Dimensions inches
mm
Proximity Sensors
XS7 Inductive Sensor
Flat Rectangular, DC
209
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS7 Inductive Sensor / Flat Rectangular, DC
Specifications
Mechanical
Usable Sensing Range
XS7J 0 – 2 mm
XS7F 0 – 4 mm
XS7E 0 – 8 mm
XS7C 0 – 12 mm
XS7D 0 – 32 mm
Temperature Range Storage -40 ° to +185 ° F (-40 ° to +85 ° C)
Operational -13 ° to +158 ° F (-25 ° to +70 ° C)
Enclosure Rating NEMA Type 1,4X,12
IEC Type IP68 Cable version / IP67 Connector version
Vibration 25 g, amplitude +/- 2mm (f=10-55 Hz)
Shock Resistance 50 g duration 11ms
Differential (%of Sr) 1-15%
Repeatability (% of Sr) 2%
LED Indicator Yellow output
Enclosure Material PBT
Cable PVR, 3x0.34mm2
Connector Nano conn. 3 pin M8 / Micro conn. 4 pin M12
Electrical 2 wire 3 wire
Voltage Range 12 – 24 Vdc 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc 10 – 36 Vdc
Voltage Drop 2 V 4 V
Current Limit Maximum 100 mA 100 mA
Current consumption 0.5 mA 10 mA
Power up Delay (max.)
XS7J 10 ms 5 ms
XS7F 5 ms 5 ms
XS7E 5 ms 10 ms
XS7C 5 ms 5 ms
XS7D 10 ms 30 ms
On Delay (max.)
XS7J 0.5 ms 0.1 ms
XS7F 0.5ms 0.1 ms
XS7E 0.3 ms 2 ms
XS7C 0.3 ms 2 ms
XS7D 10 ms 5 ms
Off Delay (max.)
XS7J 1 ms 0.1 ms
XS7F 5 ms 0.1 ms
XS7E 0.7 ms 6 ms
XS7C 0.7 ms 5 ms
XS7D 10 ms 15 ms
Protective Circuitry Short Circuit Protection Yes Ye s
Overload Protection Yes Ye s
Agency Listings E164869
CCN NRKH
Minimum Mounting Clearances (mm)
Side by Side Face to Face Face to
Metal Object Side by Side Face to Face Face to
Metal Object
XS7E e0.2 (4) e 0.9 (24) e 0.2 (6) XS7J e 0.03 (1) e 0.2 (6) e 0.08 (2)
XS7C e0.4 (10) e 2.4 (60) e 0.6 (15) XS7F e 0.8(020) e 0.4(12) e 0.12 (3)
XS7D e0.8 (20) e 4.7 (120) e 1.2 (30)
For additional cable options and lengths see p. 518
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Wiring
XS7E, XS7C, XS7D
Connector
M12 M8 Cable
Blue BU –
Brown BN +
Black BK Output
PNP/M12 or M8 NPN/M12 or M8
M8 connector, N.O. and N.C. to pin 4.
2 Wire N.O. 2 Wire N.C.
Connector M8 Cable
Blue BU –
Brown BN +
Black BK Output
XS7J, XS7F
PNP N.O. or N.C. NPN N.O. or N.C.
2 Wire N.O. 2 Wire N.C.
12
43
13
4
-
BN/1
BU/3
+
PNP BK/4 (NO)
BK/2 (NC)
BN/1
BU/3
+
-
BK/4 (NO)
BK/2 (NC)
NPN
BN/3
BU/4
+/-
-/+
NO
BN/1
BN/1
+/
-
-/
+
NC
BU/2 (M12)
BU/4 (M8)
13
4
-
BN/1
BU/3
+
PNP BK/4
BN/1
BU/3
+
-
BK/4
NPN
BN/3
BU/4
+/-
-/+
NO
BN/1
BN/1
BU/2
+/
-
-/
+
NC
®
ee
e
eee
OSICONCEPT Proximity Sensors
XS6 Extended Range and Auto-Adaptable Inductive Sensor
Metal Tubular, DC and AC/DC
© 1997-2002 Schneider Electric All Rights Reserved
210 10/02
Proximity Sensors
XS6 Extended Range Inductive Sensor / Metal Tubular, DC and AC/DC
Features:
Entire range of fully shielded metal body cylindrical inductive proximity sensors.
Increased sensing range, fully shielded
2 wire AC/DC and 3 wire DC
Normally Open or Normally Closed outputs available
Cable and connector versions
PNP or NPN, DC
Self-Teach available on 12-30mm versions
aTo order a normally closed (N.C.) version change the A to B, example: XS518B1PAL2 to XS518B1PBL2.
Self-teach version only
q5m cable length available with L5 suffix / 10m cable length available with L10 suffix.XS
6 Extended Range Inductive Sens or / Metal Tubul ar, DC and
Nominal Sensing
Distance
Circuit
Type
Output
Mode Voltage Range
Load
Current
Max.
Operating
Frequency Catalog Number
DC AC
8 mm Diameter, 2 m (6.6’) cable q
2.5 mm PNP N.O.a12-48 Vdc 200 mA 5000 Hz XS608B1PAL2
2.5 mm NPN N.O.a12-48 Vdc 200 mA 5000 Hz XS608B1NAL2
8 mm Diameter, M12 connector
2.5 mm PNP N.O.a12-48 Vdc 200 mA 5000 Hz XS608B1PAM12
2.5 mm NPN N.O.a12-48 Vdc 200 mA 5000 Hz XS608B1NAM12
12 mm Diameter, 2 m (6.6’) cable q
4 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 4000 Hz 25 Hz XS612B1MAL2
4 mm PNP N.O.a12-48 Vdc 200 mA 5000 Hz XS612B1PAL2
4 mm NPN N.O.a12-48 Vdc 200 mA 5000 Hz XS612B1NAL2
12 mm Diameter, M12 connector
4 mm 2 wire N.O.a24-240 Vac/24-210 Vdc 1.5-100 mA 4000 Hz 25 Hz XS612B1MAU20
4 mm PNP N.O.a12-48 Vdc 200 mA 5000 Hz XS612B1PAM12
4 mm NPN N.O.a12-48 Vdc 200 mA 5000 Hz XS612B1NAM12
18 mm Diameter, 2 m (6.6’) cable q
8 mm 2 wire N.O.a24-240 Vac/24-210 Vdc 1.5-100 mA 3000 Hz 25 Hz XS618B1MAL2
8 mm PNP N.O.a12-48 Vdc 200 mA 2000 Hz XS618B1PAL2
8 mm NPN N.O.a12-48 Vdc 200 mA 2000 Hz XS618B1NAL2
18 mm Diameter, M12 connector
8 mm 2 wire N.O.a24-240 Vac/24-210 Vdc 1.5-100 mA 3000 Hz 25 Hz XS618B1MAU20
8 mm PNP N.O.a12-48 Vdc 200 mA 2000 Hz XS618B1PAM12
8 mm NPN N.O.a12-48 Vdc 200 mA 2000 Hz XS618B1NAM12
30 mm Diameter, 2m (6.6’) cable q
15 mm 2 wire N.O.a24-240 Vac/24-210 Vdc 1.5-100 mA 2000 Hz 25 Hz XS630B1MAL2
15 mm PNP N.O.a12-48 Vdc 200 mA 1000 Hz XS630B1PAL2
15 mm NPN N.O.a12-48 Vdc 200 mA 1000 Hz XS630B1NAL2
30 mm Diameter, M12 connector
15 mm 2 wire N.O.a24-240 Vac/24-210 Vdc 1.5-100 mA 2000 Hz 25 Hz XS630B1MAU20
15 mm PNP N.O.a12-48 Vdc 200 mA 1000 Hz XS630B1PAM12
15 mm NPN N.O.a12-48 Vdc 200 mA 1000 Hz XS630B1NAM12
Self – Teach version (Auto-Adaptable)
12 mm Diameter, M12 connector pigtail 0.1m
5 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS612B2PAL01M12
5 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS612B2NAL01M12
18 mm Diameter, M12 connector pigtail 0.1m
9 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS618B2PAL01M12
9 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS618B2NAL01M12
30 mm Diameter, M12 connector pigtail 0.1m
15 mm PNP N.O.a12-24 Vdc 100 mA 1000 Hz XS630B2PAL01M12
15 mm NPN N.O.a12-24 Vdc 100 mA 1000 Hz XS630B2NAL01M12
Minimum Mounting Clearances " (mm)
Auto-Adaptable Extended Range
Side by Side Face to Face Side by Side Face to Face Face to Metal Object
Flush Not Flush Flush Not Flush 8e 0.1 (3) e 0.7 (18) e 0.17 (4.5)
12 e 0.55 (14) 1.9 (50) e 1.9 (50) 3.9 (100) 12 e 0.2 (4) e 0.9 (24) e 0.2 (6)
18 e 1.1 (28) 3.9 (100) e 3.9 (100) 7.9 (200) 18 e 0.4 (10) e 2.4 (60) e 0.6 (15)
30 e 1.9 (48) 7.1 (180) e 7.1 (180) 14.1 (360) 30 e 0.8 (20) e 4.7 (120) e 1.2 (30)
801267
XS6 ••B1••L2
520030
XS6••B2••L01M12
inches (mm)
Dimensions
Cable Connector
ab a b
8 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (40)
12 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (42)
18 2.3 (60) 0.09 (51) 2.8 (72.2) 2.0 (51)
30 2.3 (60) 0.09 (51) 2.8 (72.2) 2.0 (51)
a
bc
inches (mm)
Dimensions
Connector M12
abc
12 1.9 (50) 1.4 (37) 0.2 (5)
18 2.3 (60) 1.5 (38.5) 0.31 (8)
30 29.9 (760) 1.5 (38.5) 0.5 (13)
M12
20
2.44
62 a
bc
XS6 ••B1••M12
Dual Dimensions inches
mm
thread
M30x1.5
thread
M18x1
thread
M12x1
thread
M8x1
e
e
e
ee
OSICONCEPT Proximity Sensors
XS6 Extended Range and Auto-Adaptable Inductive Sensor
Metal Tubular, DC and AC/DC
211
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Specifications
Accessories
Mechanical Extended Range Auto-Adaptable
Shielded Non-shielded
Fine Detection Zone
08 mm 0 – 2 mm
12 mm 0 – 3.2 mm 1.7 - 3.4 mm 1.7 - 5 mm
18 mm 0 – 6.4 mm 3.5 – 6 mm 3.5 – 9 mm
30 mm 0 – 12 mm 6 – 12 mm 6 – 18 mm
Sn
12 mm 0 - 3.4 mm 0 - 5 mm
18 mm 0 – 6 mm 0 – 9 mm
30 mm 0 – 12 mm 0 – 18 mm
Temperature Range Storage -40 ° to +185 ° F (-40 ° to +85 ° C)
Operation -13 ° to +158 ° F (-25 ° to +70 ° C)
Enclosure Rating NEMA Type 3,4X,6P,12,13
IEC Type IP68 cable versions (IP67 connector versions)
Enclosure Material Case Nickel Plated Brass
Face PBT
Max. Tightening Torque
08 mm 9 N•m (6.7 lb-ft)
12 mm 15 N•m (11 lb-ft)
18 mm 35 N•m (26 lb-ft)
30 mm 50 N•m (37 lb-ft)
Vibration 25 g, amplitude +/- 2mm (f=10-55 Hz)
Shock Resistance 50 g duration 11ms
Differential (%of Sr) 15%
Repeatability (% of Sr) 3%
LED Indicator Power & Teach Green
Output Yel l ow
Cable PVR 3x0.34 mm 2/PVR2x0.5 mm2PVR – 4.2 mm O.D.
Connector M12 4 pin / U20 3 pin Micro conn. M12 Micro conn. 4 pin
Electrical 2 wire AC/DC 3 wire DC Auto-adaptable DC
Voltage Range 24-240 Vac; 24-210 Vdc 12 – 48 Vdc 12 - 24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10 – 58 Vdc 10 – 36 Vdc
Voltage Drop 5.5 V 2 V 2 V
(max.) Leakage (Residual) Current-open state 0.8 mA
Current consumption 10 mA 10 mA
Maximum Current Limit AC: 5. . .300 mA / DC: 5. . . 200 mA 200 mA 100 mA
Power up Delay (max.) 20 ms-12 mm / 25 ms-18/30 mm 5 ms 5ms
On Delay (max.)
08mm 0.2 ms
12mm 0.5 ms 0.2 ms 0.3 ms
18mm 0.5 ms 0.3 ms 0.3 ms
30mm 0.5 ms 0.6 ms 0.3 ms
Off Delay (max.)
08mm 0.2 ms
12mm 0.2 ms 0.2 ms 0.7 ms
18mm 0.5 ms 0.7 ms 0.7 ms
30mm 2 ms 1.4 ms 0.7 ms
Maximum Operating
Frequency
08mm 2500 Hz
12mm AC: 25 Hz / DC: 1000 Hz 2500 Hz 1000 Hz
18mm AC: 25 Hz / DC: 1000 Hz 1000 Hz 1000 Hz
30mm AC: 25 Hz / DC: 500 Hz 500 Hz 1000 Hz
Protective Circuitry
Short Circuit
Protection No Ye s Ye s
Overload Protection Yes Ye s Ye s
Reverse Polarity
Protection Yes Ye s Ye s
Agency Listings
Description Catalog Number
Mounting bracket for teach connector XSZBPM12
8mm tubular mounting bracket XSZB108
12mm tubular mounting bracket XSZB112
18mm tubular mounting bracket XSZB118
30mm tubular mounting bracket XSZB130
XSZB1kk XSZBPM12
For additional cable options and lengths see p. 518
Connector Cables
(M12 or D suffix; U20 or K suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
Wiring
3 Wire Selectable
Connector M12 Cable
Blue BU –
Brown BN +
Black BK Output
PNP NPN
Connector M12 Cable
Blue BU –
Brown BN +
Black BK Output
PNP NPN
2 Wire AC/DC
Connector U20 Cable
Blue BU –
Brown BN +
Black BK Output
2 Wire Non-Polarized
12
43
BN/1
BU/3
+
PNP BK/4 (NO)
BK/2 (NC)
BN/1
BU/3
+
BK/4 (NO)
BK/2 (NC)
NPN
12
43
+
PNP
1
3
4
BN
BK
BU
+
NPN
1
3
4
BN
BK
BU
1
32
BN/2
BU/3
®
Proximity Sensors
XS5 Inductive Sensor
Metal Tubular, DC
©1997- 2002 Schneider Electric All Rights Reserved
212 10/02
Proximity Sensors
XS5 Inductive Sensor / Metal Tubular, DC
Features:
Complete range of cylindrical proximity sensors dedicated to OEM’s and their applications.
Low cost shielded cylindrical inductive proximity sensors
2 and 3 wire DC
Normally Open or Normally Closed outputs available
Cable and connector versions
PNP or NPN
aTo order a normally closed (N.C.) version change the A to B, example: XS518B1PAL2 to XS518B1PBL2.
q5m cable length available with L5 suffix / 10m cable length available with L10 suffix.XS
Nominal Sensing
Distance
Circuit
Type
Output
Mode
Voltage
Range
Load Current
Maximum
Operating
Frequency Catalog Number
8 mm Diameter, 2 m (6.6’) cable q
1.5 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 4000 Hz XS508B1DAL2
1.5 mm PNP N.O.a12-24 Vdc 200 mA 5000 Hz XS508B1PAL2
1.5 mm NPN N.O.a12-24 Vdc 200 mA 5000 Hz XS508B1NAL2
8 mm Diameter, M12 connector
1.5 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 4000 Hz XS508B1DAM12
1.5 mm PNP N.O.a12-24 Vdc 200 mA 5000 Hz XS508B1PAM12
1.5 mm NPN N.O.a12-24 Vdc 200 mA 5000 Hz XS508B1NAM12
12 mm Diameter, 2 m (6.6’) cable q
2 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 4000 Hz XS512B1DAL2
2 mm PNP N.O.a12-24 Vdc 200 mA 5000 Hz XS512B1PAL2
2 mm NPN N.O.a12-24 Vdc 200 mA 5000 Hz XS512B1NAL2
12 mm Diameter, M12 connector
2 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 4000 Hz XS512B1DAM12
2 mm PNP N.O.a12-24 Vdc 200 mA 5000 Hz XS512B1PAM12
2 mm NPN N.O.a12-24 Vdc 200 mA 5000 Hz XS512B1NAM12
18 mm Diameter, 2 m (6.6’) cable q
5 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 3000 Hz XS518B1DAL2
5 mm PNP N.O.a12-24 Vdc 200 mA 2000 Hz XS518B1PAL2
5 mm NPN N.O.a12-24 Vdc 200 mA 2000 Hz XS518B1NAL2
18 mm Diameter, M12 connector
5 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 3000 Hz XS518B1DAM12
5 mm PNP N.O.a12-24 Vdc 200 mA 2000 Hz XS518B1PAM12
5 mm NPN N.O.a12-24 Vdc 200 mA 2000 Hz XS518B1NAM12
30 mm Diameter, 2 m (6.6’) cable q
10 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 2000 Hz XS530B1DAL2
10 mm PNP N.O.a12-24 Vdc 200 mA 1000 Hz XS530B1PAL2
10 mm NPN N.O.a12-24 Vdc 200 mA 1000 Hz XS530B1NAL2
30 mm Diameter, M12 connector
10 mm 2 wire N.O.a12-48 Vdc 1.5-100 mA 2000 Hz XS530B1DAM12
10 mm PNP N.O.a12-24 Vdc 200 mA 1000 Hz XS530B1PAM12
10 mm NPN N.O.a12-24 Vdc 200 mA 1000 Hz XS530B1NAM12
Minimum Mounting Clearances (mm)
Side by Side Face to Face Facing a Metal Object
8e 0.11 (3) e 0.7 (18) e 0.17 (4.5)
12 e 0.15 (4) e 0.9 (24) e 0.2 (6)
18 e 0.4 (10) e 2.4 (60) e 0.6 (15)
30 e 0.8 (20) e 4.7 (120) e 1.2 (30)
801267
XS5 ••B1••L2
inches (mm)
Dimensions
2 Wire
Cable Connector
abab
8 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (40)
12 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (40)
18 2.0 (52.5) 1.7 (44) 2.5 (64.6) 1.7 (44)
30 1.9 (50) 1.6 (42) 2.5 (64.2) 1.6 (41)
3 Wire
Cable Connector
abab
8 1.3 (33) 1.0 (25) 1.6 (42) 1.0 (26)
12 1.3 (33) 1.0 (25) 1.9 (48) 1.1 (29)
18 1.4 (36.5) 1.1 (28) 1.9 (48.6) 1.1 (28)
30 1.6 (40.6) 1.2 (32) 2.0 (50.7) 1.3 (32)
a
b
a
b
XS5 ••B1••M12
Dual Dimensions inches
mm
thread
M30x1.5
thread
M18x1
thread
M12x1
thread
M8x1
e
e
e
Proximity Sensors
XS5 Inductive Sensor
Metal Tubular, DC
213
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS5 Inductive Sensor / Metal Tubular, DC
Specifications
Accessories
Mechanical
Usable Sensing Range
08mm 0 – 1.2 mm
12mm 0 – 1.6 mm
18mm 0 – 4 mm
30mm 0 – 8 mm
Temperature Range Storage -40 ° to +185 ° F (-40 ° to +85 ° C)
Operation -13 ° to +158 ° F (-25 ° to +70 ° C)
Enclosure Rating NEMA Type 3,4X,6P,12,13
IEC Type IP68 cable version (except 8mm and connector version: IP67)
Enclosure Material Case Nickel Plated Brass
Face PBT
Max. Tightening Torque
08mm 5 N•m (3.7 lb-ft)
12mm 6 N•m (4.4 lb-ft)
18mm 15 N•m (11 lb-ft)
30mm 40 N•m (29.5 lb-ft)
Vibration 25 g, amplitude +/- 2 mm (f=10-50 Hz)
Shock Resistance 50 g duration 11 ms
Differential (%of Sr) 15%
Repeatability (% of Sr) 3%
LED Indicator Output status
Cable PVR 2x0.5 mm2PVR 3x0.34 mm2
Connector M12 4pin M8 3 pin / M12 4pin
Electrical 2 wire 3 wire
Voltage Range 12 – 48 Vdc 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 58 Vdc 10 – 36 Vdc
Voltage Drop 4V 2V
Maximum Load Current 1.5 …100 mA 200 mA
(max.) Leakage (Residual) Current-open state 0.5mA
Current consumption 10 mA
Power up Delay (max.) 5 ms 5 ms
On Delay (max.)
08mm 0.2 ms 0.1 ms
12mm 0.2 ms 0.1 ms
18mm 0.2 ms 0.15 ms
30mm 0.3 ms 0.2 ms
Off Delay (max.)
08mm 0.2 ms 0.1 ms
12mm 0.2 ms 0.1 ms
18mm 0.2 ms 0.35 ms
30mm 0.3 ms 0.7 ms
Protective Circuitry
Short Circuit Protection Ye s Ye s
Overload Protection Ye s Ye s
Radio Frequency Immunity (RFI) IEC 61000-4-3 Level 3 IEC 61000-4-3 Level 3
Reverse Polarity Protection Ye s Ye s
Agency Listings UL CE
Description Catalog Numbers
8mm tubular mounting bracket XSZB108
12mm tubular mounting bracket XSZB112
18mm tubular mounting bracket XSZB118
30mm tubular mounting bracket XSZB130
For additional cable options and lengths see p. 518
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
Wiring
2 Wire
Connector M12 Cable
Blue BU –
Brown BN +
2 Wire Non Polarized
3 Wire
Connector
M8 M12
Cable
Blue BU –
Brown BN +
Black BK Output
PNP NPN
12
43
BN/2 + / -
+ / -
BU/3
13
4
12
43
BN/1
BU/3
+
PNP BK/4 (NO)
BK/2 (NC)
BN/1
BU/3
+
BK/4 (NO)
BK/2 (NC)
NPN
®
CSA
OSICONCEPT Proximity Sensors
XS9 Application Specific Inductive Sensor
Flat Rectangular Analog Output, DC
©1997- 2002 Schneider Electric All Rights Reserved
214 10/02
Proximity Sensors
XS9 Application Specific Inductiv e Sensor / Flat Rectangular Analog Output, DC
Features:
DC output current is directly proportional to the target distance
Four sizes: F (8x15x32); E (13x26x26); C (15x40x40); and D (26x80x80)
Cable and connector versions
q5m cable length available with L5 suffix / 10m cable length available with L10 suffix.XS
Nominal Sensing
Distance Circuit Type Voltage Range Output Operating
Frequency Catalog Number
Size F (8x15x32) 2 m(6.6’) cable q
5 mm 3 wire 12-24 Vdc 1-10 V 2000 Hz XS9F111A1L2
5 mm 3 wire 12-24 Vdc 4-20 mA 2000 Hz XS9F111A2L2
Size F (8x15x32) M8 connector pigtail 0.1 m
5 mm 3 wire 12-24 Vdc 1-10 V 2000 Hz XS9F111A1L01M8
5 mm 3 wire 12-24 Vdc 4-20 mA 2000 Hz XS9F111A2L01M8
Size E (13x26x26) 2m (6.6’) cable q
10 mm 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9E111A1L2
10 mm 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9E111A2L2
Size E (13x26x26) M12 connector pigtail 0.1 m
10 mm 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9E111A1L01M12
10 mm 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9E111A2L01M12
Size C (15x40x40) 2 m (6.6’) cable q
15 mm 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9C111A1L2
15 mm 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9C111A2L2
Size C (15x40x40) M12 connector pigtail 0.1 m
15 mm 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9C111A1L01M12
15 mm 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9C111A2L01M12
Size D (26x80x80) 2 m (6.6’) cable q
40 mm 3 wire 12-24 Vdc 1-10 V 100 Hz XS9D111A1L2
40 mm 3 wire 12-24 Vdc 4-20 mA 100 Hz XS9D111A2L2
Size D (26x80x80) M12 connector
40 mm 3 wire 12-24 Vdc 1-10 V 100 Hz XS9D111A1M12
40 mm 3 wire 12-24 Vdc 4-20 mA 100 Hz XS9D111A2M12
Minimum Mounting Clearances " (mm)
Side by Side Face to Face Face to Metal Object
XS9F e0.08 (2) e 0.47 (12) e 0.12 (3)
XS9E e0.16 (4) e 0.9 (24) e 0.23 (6)
XS9C e0.40 (10) e 2.3 (60) e 0.6 (15)
XS9D e0.8 (20) e 4.7 (120) e 1.2 (30)
XS9F111kkkL2 XS9E111kkkL2
XS9D111kkkL2
inches (mm)
Dimensions
XS9 F XS9E
XS9C/D
A
L2 A M12BCDEF
E0.55
(14) 1.0
(26)
0.5
(13)
0.3
(8.8)
0.8
(20)
0.1
(3.5)
C0.55
(14) 1.6
(40)
0.6
(15)
0.4
(9.8)
1.3
(33)
0.1
(4.5)
D0.9
(23)
0.5
(14)
3.1
(80)
1.0
(26)
0.6
(16)
2.5
(65)
0.2
(5.5)
0.3
8
1.2 (32)
0.6 (15)
0.3
9
Ø3
F
B
E
B
E
E
C
D
A
B
B
F
Dual Dimensions inches
mm
eee
Cally
ourlocal
fieldsalesoffice
foravailability!
OSICONCEPT Proximity Sensors
XS9 Application Specific Inductive Sensor
Flat Rectangular Analog Output, DC
215
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS9 Application Specific Inductiv e Sensor / Flat Rectangular Analog Output, DC
Specifications
Mechanical
Usable Sensing Range
XS9F 1…5 mm
XS9E 1…10 mm
XS9C 2…15 mm
XS9D 5…40 mm
Temperature Range Storage -40 ° to +185 ° F (-40 ° to +85 ° C)
Operation -13 ° to +158 ° F (-25 ° to +70 ° C)
Enclosure Rating NEMA Type 1, 4X (indoor only) 12
IEC Type IP68 cable version / IP67 connector version
Vibration 25 g, amplitude +/-2 mm (f=10 to 55 Hz)
Shock 50 g, duration 11 ms
Enclosure material PBT
Cable PVR 3x0.34 mm2
Connector M8 Nano conn. 3 pin / M12 Micro conn. 4 pin
Electrical 2 wire DC
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Max. output current drift with the rated operating temperature <10%
Linearity error +/- 5%
Protective Circuitry Short Circuit Protection Ye s
Overload Protection Ye s
Agency Listings
Output Curves
0 to 10 V
XS9F11 XS9E XS9C XS9D
Sn = 1 . . . 5 mm Sn = 1 . . . 10 mm Sn = 2 . . . 15 mm Sn = 5 . . . 40 mm
Distance in mm.
Output Current Resistance Output Voltage Resistance
12 V 0 ... 10 mA R 560 0 - 10 V Indeterminate
24 V 0 ... 10 mA R 1500 0 - 10 V R = 1000
Note: Ensure a minimum of 5 V between the (+) positive and the sensor output (terminal 3).
4 to 20 mA
XS9F11 XS9E XS9C XS9D
Sn = 1 . . . 5 mm Sn = 1 . . . 10 mm Sn = 2 . . . 15 mm Sn = 5 . . . 40 mm
Distance in mm.
Output Current Resistance
12 V 4 ... 20 mA R 82
24 V 4 ... 20 mA R 560
Note: Ensure a minimum of 10 V between the (+) positive and the sensor output (terminal 3).
W
iring
Connector
M8 M12 Cable
Blue BU –
Brown BN +
Black BK Output
3 Wire (0 - 10 V)
2 Wire (4 - 20 mA)
13
4
12
43
BN/1
BK/4
BU/3 R
mA
+
Is
U=R.Is
Output Voltage
BN/1
BK/4
BU/3 R
mA
+
Is
U=R.Is
Output Current
For additional cable options and lengths see p. 518
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
®
0 2.5 5
0
1
2
3
4
5
6
7
8
9
10
11
60510
0
1
2
3
4
5
6
7
8
9
10
11
12
0 7.5 15
0
1
2
3
4
5
6
7
8
9
10
11
17
02040
0
1
2
3
4
5
6
7
8
9
10
11
50
0 2.5 5
0
2
4
6
8
10
12
14
16
18
20
22
6
0
2
4
6
8
10
12
14
16
18
20
22
0 5 10 13
0 7.5 15
0
2
4
6
8
10
2
14
16
18
20
22
18.5
0 20 40
0
2
4
6
8
10
2
14
16
18
20
22
50
OSICONCEPT Proximity Sensors
XS9 Application Specific Inductive Sensor
Flat Rectangular Motion Detection, DC and AC/DC
© 1997-2002 Schneider Electric All Rights Reserved
216 10/02
Proximity Sensors
XS9 Application Specific Inductiv e Sensor / Flat Rectangular Motion Detection, DC and AC/DC
Features:
Universal AC/DC versions
Linear speed threshold adjustment
Built-in fixed start up delay to overcome start up inertia
Reverse polarity protection on DC models
Ease of mounting (flat body style)
Principle and Applications
cInductive proximity sensors for monitoring rotation or rolling speed operate by comparing a
speed threshold that has been preset by the operator with an instantaneous measurement of
the speed of the moving part to be monitored or protected.
cThese devices provide a simple and economical solution for monitoring drift, belt breakage,
couplings, overloads, etc.
cThey are commonly used for applications such as crushers and grinders, mixers and
blenders, pumps, centrifuges and centrifugal separators, conveyor belts, bucket elevators,
archimedean screws, etc.
Installation and Setup
Installing and Positioning the Sensor
cThe sensor must be properly positioned at the outset to ensure that all of the target points
on the moving part to be monitored can be detected. The XS9 sensor facilitates this task with
its ability to operate as a standard inductive sensor (Telemecanique patent pending).
cThanks to this system, positioning is 100% reliable and can be checked at any time without
changing the product parameters.
Self-teaching Speed Setup
cThe normal or reference speed for the moving part (1) to be monitored can be set by simply
pressing the self-teaching button (2). It is then confirmed with the display LED.
In case of uncertainty, the product can be restarted at any time in order to return to the
factory setting.
1. In order to ensure that the moving part can attain its normal speed (inertia), the product
output remains closed for nine seconds.
2. By default, the sensor’s underspeed trip speed is equivalent to the preset speed - 30%.
Example: if the preset speed is 1000 rotations/min., underspeed tripping will occur when
the speed of the moving part falls below 1000 - 1000 x 0.3 = 700 rotations/min.
Thresholds of -20%, -11% and -6% can be obtained by pressing the self-teaching button.
Nominal
Sensing
Distance
Circuit
Type
Threshold
Range
(Pulse/Min.)
Voltage
Range
Load Current
Maximum
Maximum
Frequency
(Pulse/Min.)
Start-up
Delay Catalog Number
Size E (13x26x26 mm) M12 pigtail, 0.1 m
10 mm PNP 6-6000 12-24 Vdc 100 mA 48000 9 sec. XS9E11RPB1L01M12
Size E (13x26x26 mm) U20 pigtail, 0.1 m
10 mm 2 wire 6-6000 24-240 Vac/
24-210 Vdc 5…100 mA 48000 9 sec. XS9E11RMB3L01U20
Size C (15x40x40 mm) M12 pigtail, 0.1 m
15 mm PNP 6-6000 12-24 Vdc 200 mA 48000 9 sec. XS9C11RPB1L01M12
Size C (15x40x40 mm) U20 pigtail, 0.1 m
15 mm 2 wire 6-6000 24-240 Vac/
24-210 Vdc
5…200 mA AC
5…300 mA DC 48000 9 sec. XS9C11RMB3L01U20
Self-teaching LED
Self-teaching Button
Power
Supply
Output
LED
Reference
Speed
> 7 Sec.
Slow Flash
> 3 Sec.
OSICONCEPT Proximity Sensors
XS9 Application Specific Inductive Sensor
Flat Rectangular Motion Detection, DC and AC/DC
217
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS9 Application Specific Inductiv e Sensor / Flat Rectangular Motion Detection, DC and AC/DC
Specifications
a1/Fr in the start up delay formula is the actual preset frequency adjusted via potentiometer
Accessories
Mechanical
Usable Sensing Range XS9E 0 – 8 mm
XS9C 0 – 12 mm
Temperature Range Storage -40 ° to +185 ° F (-40 ° to +85 ° C)
Operation -13 ° to +158 ° F (-25 ° to +70 ° C)
Enclosure Rating NEMA Type 1, 4X,12
IEC Type IP67
Vibration 25 g, amplitude +/-2 mm (f=10 to 55 Hz)
Shock Resistance 50 g, duration 11 ms
LED Indicator Output Yellow
Power Green
Enclosure material PBT
Connector DC: M12 4 pin; AC/DC: U20 3 pin
Electrical 2 wire AC/DC 3 wire DC
Voltage Range 24 – 240 Vac/24-210 Vdc 12 – 24 Vdc
Voltage Limit (including ripple) 20 – 264 Vac/dc 10 – 36 Vdc
Voltage Drop 5.5 V 2 V
(max.) Leakage (Residual) Current-open state 1.5 mA
Current consumption 10 mA
Load Current Maximum
XS9E 100 mA 5…100 mA
XS9C 200 mA 5…200 mA; DC
5…300 mA; AC
Max. Frequency (Pulse/Min.) 48000
Start up delay (max.) XS9E 9 seconds + 1/Fr a
XS9C 9 seconds + 1/Fr a
Protection Circuitry Overload Protection Yes
Short Circuit Protection Yes
Agency Listings
Description Catalog Number
Teach connector mounting bracket XSZBPM12
Minimum Mounting Clearances (mm)
Side by Side Face to Face
XS9E e1.6 (40) e 3.1 (80)
XS9C e2.4 (60) e 4.7 (120)
For additional cable options and lengths see p. 518
Connector Cables
(M12 or D suffix; U20 or K suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 9
XSZBPM12
Wiring
Connector
M12 0.5" UNF Cable
Blue BU
Brown BN +
Black BK Output
3 Wire DC
XS911RPBL01M12
2 Wire AC/DC
XS911RMBL01U2
2
31
32
2
3
inches (mm)
Dimensions
XS9 E/C
ABCD
E0.55
(14)
1.0
(26)
0.5
(13)
0.3
(8.8)
0.8
(20)
0.1
(3.5)
C0.55
(14)
1.6
(40)
0.6
(15)
0.4
(9.8)
1.3
(33)
0.1
(4.5)
E
E
C
D
A
B
B
F
F
B
E
B
0.8
20 M12; 1/2 UNF
2.4 (62)
®
ee
Proximity Sensors
XS Tubular, Inductive Sensors
4 mm Diameter, DC
©1997- 2002 Schneider Electric All Rights Reserved
218 10/02
Proximity Sensors
XS Tubular, Inductive Sensors / 4 mm Diameter, DC
Features
Rugged case designed for the industrial environment
Mounting space savings due to short length
Significant replacement time savings by using the patented plastic mounting bracket (no
gauging) or connectors
Trouble-free operation ensured by extensive protective circuitry
Works with 24 V secondary transformers
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version, change the A to B, example: XS1L04PA310 to XS1L04PB310.
Nominal Sensing
Distance
Circuit
Type
Volt age
Range
Output
Mode
Operating
Frequency
Mating
Connector Style
(See p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
1 mm PNP 5-24 V N.O.a5000 Hz XS1L04PA310
1 mm NPN 5-24 V N.O.a5000 Hz XS1L04NA310
Shielded, connector - nano style
1 mm PNP 5-24 V N.O.a5000 Hz 1 thru 8 XS1L04PA310S
1 mm NPN 5-24 V N.O.a5000 Hz 1 thru 8 XS1L04NA310S
Stainless steel case
Shielded, 2 m (6.6’) cable
0.8 mm PNP 5-24 V N.O. 5000 Hz XS1L04PA311
0.8 mm NPN 5-24 V N.O. 5000 Hz XS1L04NA311
Shielded, connector - nano style
0.8 mm PNP 5-24 V N.O. 5000 Hz 1 thru 8 XS1L04PA311S
0.8 mm NPN 5-24 V N.O. 5000 Hz 1 thru 8 XS1L04NA311S
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 2/.08 e: 12/.47 e: 3/.12 D: 4/.16
1.14
29
LED
1.61
41
LED
XS1Lk
XS1LkS
Dual Dimensions inches
mm
Facing a metal object
e
Side by side
e
Face to face
e
Mounted in a metal support
D
Proximity Sensors
XS Tubular, Inductive Sensors
4 mm Diameter, DC
219
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, Inductive Sensors / 4 mm Diameter, DC
Specifications
Note: Refer to page 351, for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded Brass case 0 to 0.8 mm
Stainless Steel Case 0 to 0.64 mm
Standard temperature range -25° C to +70° C (-13° F to +158° F)
Enclosure rating - cable NEMA Type 3, 4X, 6P, 12, 13
(for connector, see p. 518) CENELEC Type IP67
Enclosure material
Brass case Nickel plated Brass
Stainless steel case Stainless steel
Sensing face PBT
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2mm, f =10-55Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11ms
Standard target size (steel) 4 mm x 4 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type Side mounted LED: Shows output status
Cable 3 wire 27 AWG (0.11mm2), PvR
Electrical
Voltage range – nominal 5 to 24 Vdc
Voltage limit (including ripple) 5 to 30 Vdc
Voltage drop (across switch), closed state 2 V
Maximum load current 100 mA
Current consumption (no load) 10 mA
On delay (max.) 0.1 ms
Off delay (max.) 0.1 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 6100-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type only) Down to -40° C (-40° F) TF
Extended cable length 5 meter cable L1
10 meter cable L2
Accessories
Description Catalog Number
Mounting bracket, plastic XSZB104
Mounting bracket, diecast zinc 8316 04
F
or additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298
Connector Cables (M8 or S suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZB1kk 8316kk
Wiring
Connector M8 Cable
Blue BU –
Brown BN +
Black BK Output
13
4
BK/2 NC
BK/4 NO
3 wire NO or NC
wire color/connector pin
BN/1
BU/3
BK/4 NO
+
-
PNP
BU/3
+
-
NPN
BN/1
BK/2 NC
®
Proximity Sensors
XS Tubular, Inductive Sensors
5 mm Diameter, DC; Economy Short Length
©1997- 2002 Schneider Electric All Rights Reserved
220 10/02
Proximity Sensors
XS Tubular, Inductive Sensors / 5 mm Diameter, DC : Economy Short Length
Features
Rugged case designed for the industrial environment
Mounting space savings due to short length
Significant replacement time savings by using the patented plastic mounting bracket (no
gauging) or connectors
Trouble-free operation ensured by extensive protective circuitry
Works with 24 V secondary transformers
Metal mounting nuts included, die cast zinc
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version, change the A to B, example: XS1N05PA310 to XS1N05PB310
Nominal
Sensing
Distance
Circuit
Type
Volt age
Range
Output
Mode
Operating
Frequency
Mating
Connector Style
(See p.518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
1 mm PNP 5-24 V N.O.a5000 Hz XS1N05PA310
1 mm NPN 5-24 V N.O.a5000 Hz XS1N05NA310
Stainless steel case
Shielded, 2 m (6.6’) cable
0.8 mm PNP 5-24 V N.O. 5000 Hz XS1N05PA311
0.8 mm NPN 5-24 V N.O. 5000 Hz XS1N05NA311
Shielded, connector - nano style
0.8 mm PNP 5-24 V N.O. 5000 Hz 1 thru 8 XS1N05PA311S
0.8 mm NPN 5-24 V N.O. 5000 Hz 1 thru 8 XS1N05NA311S
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 2/.08 e: 12/.47 e: 3/.12 D: 5/.20
LED
LED
.94
.94
24
24
29
41
1.14
1.61
thread
M5x0.5
Dual Dimensions inches
mm
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
Proximity Sensors
XS Tubular, Inductive Sensors
5 mm Diameter, DC; Economy Short Length
221
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, Inductive Sensors / 5 mm Diameter, DC ; Economy Short Length
Specifications
Note: Refer to page 351, for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded Brass case 0 to 0.8 mm
Stainless steel case 0 to 0.64 mm
Standard temperature range -25° C to +70° C (-13° F to +158° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Enclosure material
Brass case Nickel plated Brass
Stainless steel case Stainless steel
Sensing face PBT
Max. tightening torque Brass 1.6 N•m (1.2 lb-ft)
Stainless steel 2.2 N•m (1.75 lb-ft)
Vibration resistance
Shock resistance
(IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz
(IEC 60068.2.27) 50 G duration 11ms
Standard target size (steel) 4 mm x 4 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type Side mounted LED: Shows output status
Cable 3 wire 27 AWG (0.11 mm2), PvR
Electrical
Voltage range – nominal 5 to 24 Vdc
Voltage limit (including ripple) 5 to 30 Vdc
Voltage drop (across switch), closed state 2 V
Maximum load current 100 mA
Current consumption (no load) 10 mA
On delay (max.) 0.1 ms
Off delay (max.) 0.1 ms
Power-up delay (max.) 5 ms
Protective Circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 5 meter cable L1
10 meter cable L2
Accessories
Description Catalog Number
Metal, die cast zinc mounting nuts and lock washer XSZE105
Mounting bracket, plastic XSZB105
Mounting bracket, diecast zinc 831605
Stainless steel mounting nuts and lock washer XSZE305
For additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298
Connector Cables (M8 or S suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZB1kk 8316kk
Wiring
Connector M8 Cable
Blue BU –
Brown BN +
Black BK Output
13
4
BK/2 NC
BK/4 NO
3 wire NO or NC
wire color/connector pin
BN/1
BU/3
BK/4 NO
+
-
PNP
BU/3
+
-
NPN
BN/1
BK/2 NC
®
Proximity Sensors
XS Tubular, Inductive Sensors
6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel
©1997- 2002 Schneider Electric All Rights Reserved
222 10/02
Proximity Sensors
XS Tubular, I nductive Sensors / 6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel
Features
Faster troubleshooting aided by high visibility 360° indicators
Economy of size offered by extended range model
Reduction of relay or software logic using complementary N.O. + N.C. outputs
Significant replacement time savings by using the patented plastic mounting bracket (no
gauging) or connectors
Trouble-free operation ensured by extensive protective circuitry
Works with unregulated DC supply powered by 24 V secondary transformer
Metal mounting nuts included
Zinc diecast
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version, change A to B, example; XS1L06PA340 to XS1L06PB340.
See dimension x below.
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Operating
Frequency
Indicator
LED (see
next page)
Mating
Connector
(see p. 518)
Catalog
Number
Stainless steel case
Shielded, 2 m (6.6’) cable
1.5 mm PNP 12-24 V N.O.a5000 Hz A XS1L06PA340
1.5 mm NPN 12-24 V N.O.a5000 Hz A XS1L06NA340
1.5 mm PNP 12-24 V N.O.+N.C. 5000 Hz A XS1L06PC410
1.5 mm NPN 12-24 V N.O.+N.C. 5000 Hz A XS1L06NC410
Shielded, connector - nano style
1.5 mm PNP 12-24 V N.O.a5000 Hz B 1 thru 8 XS1L06PA340S
1.5 mm NPN 12-24 V N.O.a5000 Hz B 1 thru 8 XS1L06NA340S
Shielded, connector - micro style
1.5 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS1L06PA340D
1.5 mm NPN 12-24 V N.O. 5000 Hz B 11,12,14,15,16 XS1L06NA340D
Nickel plated brass case
Shielded, EXTENDED RANGE 2m (6.6’) cable
2.5 mm PNP 12-24 V N.O.a2500 Hz A XS1L06PA349
2.5 mm NPN 12-24 V N.O.a2500 Hz A XS1L06NA349
Shielded, EXTENDED RANGE connector - nano style
2.5 mm PNP 12-24 V N.O. 2500 Hz B 1 thru 8 XS1L06PA349S
2.5 mm NPN 12-24 V N.O. 2500 Hz B 1 thru 8 XS1L06NA349S
Shielded, EXTENDED RANGE connector - micro style
2.5 mm PNP 12-24 V N.O. 2500 Hz B 11,12,13,15,16 XS1L06PA349D
2.5 mm NPN 12-24 V N.O. 2500 Hz B 11,12,14,15,16 XS1L06NA349D
Stainless steel case
Non-shielded, 2 m (6.6’) cable
2.5 mm PNP 12-24 V N.O. 5000 Hz A XS2L06PA340
2.5 mm NPN 12-24 V N.O. 5000 Hz A XS2L06NA340
Non-shielded, connector - nano style
2.5 mm PNP 12-24 V N.O. 5000 Hz B 1 thru 8 XS2L06PA340S
2.5 mm NPN 12-24 V N.O. 5000 Hz B 1 thru 8 XS2L06NA340S
Non-shielded, connector - micro style DC
2.5 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS2L06PA340D
2.5 mm NPN 12-24 V N.O. 5000 Hz B 11,12,14,15,16 XS2L06NA340D
2.5 mm PNP 12-24 V N.O.+N.C. 5000 Hz B 11,12,13,15,16 XS2L06PC410D
2.5 mm NPN 12-24 V N.O.+N.C. 5000 Hz B 11,12,14,15,16 XS2L06NC410D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 3/.12 e:18/.71 e:4.5/.17 D: 6.5/.26; x: 0/0
XS1 Extended range e: 5/.20 e: 30/1.18 e: 7.5/.30 D: 10/.39; x: 1.6 /.06
XS2 Non-shielded e:10/.39 e: 30/1.18 e: 7.5/.30 D: 19.5/.77, H: 5/.20
1.30
33
LED
1.30
33
LED
.82
21 1.77
45
LED
1.65
42
LED
1.18
30
.11
3
LED
1.77
45
.82
21
LED
.11
3
.82
21 1.65
42
LED
1.65
42
LED
1.49
38 .15
4
LED
1.97
50
LED
XS1L06kS
XS1L06kD
XS1L06k349
XS1L06k349S
XS1L06k349
XS2L06k
XS2L06kS
XS2L06kD
XS1L06kA
XS1L06kC
Dual Dimensions inches
mm
Mounted in a metal supportFacing a metal object
e
Side to side
e
Face to face
e
D
H
Mounted in a metal support
Dx
Proximity Sensors
XS Tubular, Inductive Sensors
6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel
223
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I nductive Sensors / 6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel
Specifications
Note:Refer to p. 351, for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded Standard Range 0 to 1.2 mm
Extended Range 0 to 2 mm
Non-shielded 0 to 2 mm
Standard temperature range Standard Range -25° C to +70° C (-13° F to +158° F)
Extended Range -25° C to 50° C (13° F to 122° F)
Enclosure rating - cable
(for connector see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Enclosure material Case Nickel plated Brass
Sensing face PBT
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 6.5 mm x 6.5 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 3 wire 27 AWG (0.11mm2), PvR
4 wire (N.O. + N.C.) 28 AWG (0.08mm2), PvR
Electrical
Voltage range – nominal 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch), closed state 2V (2.6V extended range)
Maximum load current 200 mA
Current consumption (no load) 10 mA
On delay (max.) Standard Range 0.1 ms
Extended Range .2 ms
Off delay (max.) Standard Range 0.1 ms
Extended Range .2 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type and standard sensing distance only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Mounting bracket, plastic XSZB165
Mounting bracket, diecast zinc 831606
For additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk 8316kk
Wiring
Connector
M8 M12 Cable
Blue BU –
Brown BN +
Black BK Output
M8 connector, N.O. and N.C. to to pin 4.
13
4
12
43
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
3 wire NO or NC
wire color/ connector pin
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
NC WH/2
BK/4
BN/1
BU/3
+
-
PNP NO
4 wire NO + NC
NC WH/2
BK/4
BN/1
BU/3
+
-
NPN NO
®
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, DC; Economy Short Length
©1997- 2002 Schneider Electric All Rights Reserved
224 10/02
Proximity Sensors
XS Tubular, Inductive Sensors / 8 mm Diameter, DC ; Economy Short Length
Features
Faster troubleshooting aided by high visibility 360° indicators
Economy of size offered by extended range model
Significant replacement time savings by using the patented plastic mounting bracket
(no gauging) or connectors
Trouble-free operation ensured by extensive protective circuitry
Works with unregulated DC supply powered by 24 V secondary transformer
Metal mounting lock nuts included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version, change A to B, example; XS1N08PA340 to XS1N08PB340.
See dimension x below.
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Operating
Frequency
Indicator
LED (see
next page)
Mating
Connector Style
(See p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
1.5 mm PNP 12-24 V N.O.a5000 Hz A XS1N08PA340
1.5 mm NPN 12-24 V N.O.a5000 Hz A XS1N08NA340
Shielded, connector - nano style
1.5 mm PNP 12-24 V N.O.a5000 Hz B 1 thru 8 XS1N08PA340S
1.5 mm NPN 12-24 V N.O.a5000 Hz B 1 thru 8 XS1N08NA340S
Shielded, connector - micro style
1.5 mm PNP 12-24 V N.O.a5000 Hz B 11,12,13,15,16 XS1N08PA340D
1.5 mm NPN 12-24 V N.O.a5000 Hz B 11,12,14,15,16 XS1N08NA340D
Shielded, EXTENDED RANGE 2 m (6.6’) cable
2.5 mm PNP 12-24 V N.O.a2500 Hz A XS1N08PA349
2.5 mm NPN 12-24 V N.O.a2500 Hz A XS1N08NA349
Shielded, EXTENDED RANGE connector - nano style
2.5 mm PNP 12-24 V N.O.a2500 Hz B 1 thru 8 XS1N08PA349S
2.5 mm NPN 12-24 V N.O.a2500 Hz B 1 thru 8 XS1N08NA349S
Shielded, EXTENDED RANGE connector - micro style DC
2.5 mm PNP 12-24 V N.O.a2500 Hz B 11,12,13,15,16 XS1N08PA349D
2.5 mm NPN 12-24 V N.O.a2500 Hz B 11,12,14,15,16 XS1N08NA349D
Non-shielded, 2 m (6.6’) cable
2.5 mm PNP 12-24 V N.O.a5000 Hz A XS2N08PA340
2.5 mm NPN 12-24 V N.O.a5000 Hz A XS2N08NA340
Non-shielded, connector - nano style
2.5 mm PNP 12-24 V N.O. 5000 Hz B 1 thru 8 XS2N08PA340S
2.5 mm NPN 12-24 V N.O. 5000 Hz B 1 thru 8 XS2N08NA340S
Non-shielded, connector - micro style
2.5 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS2N08PA340D
2.5 mm NPN 12-24 V N.O. 5000 Hz B 11,12,14,15,16 XS2N08NA340D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 3/.12 e: 18/.71 e: 4.5/.18 D: 8/.31, H: 0 x: 0/0
XS1 Extended range e: 5/.20 e: 30/1.18 e: 7.5/.30 D: 10/.39, H: 1.6/.06 D: 8/.31, x: 1.6/.06
XS2 Non-shielded e: 10/.39 e: 30/1.18 e: 7.5/.30 D: 24/.94, H: 5/.20
LED
LED
LED
LED
LED
LED
LED
LED
LED
1.02
41
1.61
20
.78
38
1.49
23
.90
59
1.14
22
.86
4
4
4.15
.15
.15
45
1.17
24
.94
44
1.73
29
1.14
1.77
45
.94
24
1.02
26
33
1.30
26
42
1.02
1.65
33
1.30
26
XS2N08kD
Dual Dimensions inches
mm
XS2N08kS
XS2N08k
XS1N08k349D
XS1N08k349S
XS1N08k349
XS1N08kD
XS1N08kS
XS1N08k
thread
M8x1
Mounting in a metal support
D
H
Facing a metal object
e
Side by side
e
Face to face
e
Mounted in a metal support
DX
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, DC; Economy Short Length
225
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, Inductive Sensors / 8 mm Diameter, DC ; Economy Short Length
Specifications
Note:Refer to p. 351, for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded Standard Range 0 to 1.2 mm
Extended Range 0 to 2 mm
Non-shielded 0 to 2 mm
Standard temperature range Standard Range -25° C to +70° C (-13° F to +158° F)
Extended Range -25° C to 50° C (-13° F to 122° F)
Enclosure rating - cable
(see page 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Enclosure material Case Nickel plated Brass
Sensing face PBT
Max. tightening torque 5 N•m (3.7 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 8 mm x 8 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 3 wire 27 AWG (0.11mm2), PvR
Electrical
Voltage range – nominal 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch), closed state 2 V (2.6 V extended range)
Maximum load current 200 mA
Current consumption (no load) 10 mA
On delay (max.) Standard Range 0.1 ms
Extended Range .2 ms
Off delay (max.) Standard Range 0.1 ms
Extended Range .2 ms
Power-up delay (max.) Standard/Extended Range 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Extended Range: IEC 61000-4-4 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type and standard sensing distance only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Metal mounting lock nuts XSZE108
Mounting bracket, plastic XSZB108
Mounting bracket, diecast zinc 8316 08
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . . . . page 298
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk 8316kk
Wiring
Connector
M8 M12 Cable
Blue BU –
Brown BN +
Black BK Output
M8 connector, N.O. and N.C. to to pin 4.
13
4
12
43
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
3 wire NO or NC
wire color/ connector pin
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
®
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, DC; Economy Short Length, Non-corrosive
©1997- 2002 Schneider Electric All Rights Reserved
226 10/02
Proximity Sensors
XS Tubular, Inductive Sensors / 8 mm Diameter, DC ; Economy Short Length, Non-corrosive
Features
Faster troubleshooting aided by high visibility 360° indicators
Designed for chemically aggressive environments – cutting oils, grease, washdown, etc.
Significant replacement time savings using patented plastic mounting bracket
(no gauging) or connectors
Trouble-free operation ensured by extensive protective circuitry
Works with unregulated DC supply powered by 24 V secondary transformer
Plastic mounting nuts included
UL Listed, CSA Certified and CE Mark
aTo order a normally closes (N.C.) version, change A to B, example XS3P08PA340 to XS3P08PB340
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Operating
Frequency
Indicator
LED (see
next page)
Mating
Connector Style
(See p. 518)
Catalog
Number
Plastic
Non-shielded, 2 m (6.6’) cable
2.5 mm PNP 12-24 V N.O. a5000 Hz A XS4P08PA340
2.5 mm NPN 12-24 V N.O. a5000 Hz A XS4P08NA340
Non-shielded, connector - nano style
2.5 mm PNP 12-24 V N.O. 5000 Hz A 1 thru 8 XS4P08PA340S
2.5 mm NPN 12-24 V N.O. 5000 Hz A 1 thru 8 XS4P08NA340S
Non-shielded, connector - micro style
2.5 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS4P08PA340D
2.5 mm NPN 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS4P08NA340D
Minimum Mounting Clearances (mm/inches)
XS4 Non-shielded e: 10/.39 e: 30/1.18 e: 7.5/.30 D: 24/.94, H: 5/.20
LED
1.02
33
1.30
26
LED
26
42
1.02
1.65
LED
1.77
45
.94
24
XS4P08k
XS4P08kD
XS4P08kD
Dual Dimensions inches
mm
thread
M8x1
Mounting in a metal support
D
H
Facing a metal object
e
Side by side
e
Face to face
e
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, DC; Economy Short Length, Non-corrosive
227
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, Inductive Sensors / 8 mm Diameter, DC ; Economy Short Length, Non-corrosive
Specifications
Note: Refer to page 351, for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded 0 to 1.2 mm
Non-shielded 0 to 2 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see page 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Enclosure material Case PBT
Sensing face PBT
Tightening torque (max.) 1 N•m (.74 lb-ft)
Vibration resistance
Shock resistance
(IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55Hz
(IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 8 mm x 8 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
BOne LED visible from 4 quadrants: Shows output
status
Cable 3 wire 27 AWG (0.11mm2), PvR
Electrical
Voltage range – nominal 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch), closed state 2 V
Maximum load current 200 mA
Current consumption (no load) 10 mA
On delay (max.) 0.1 ms
Off delay (max.) 0.1 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE208
Mounting bracket, plastic XSZB108
For additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . page 298, 317
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 9
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
Wiring
Connector
M8 M12 Cable
Blue BU –
Brown BN +
Black BK Output
M8 connector, N.O. and N.C. to to pin 4.
13
4
12
43
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
3 wire NO or NC
wire color/ connector pin
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
®
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
228 10/02
Proximity Sensors
XS Tubular, I nductive Sensors / 8 mm Diameter, DC; Universal Standard Length
Features
Faster troubleshooting aided by high visibility 360° indicators
2-wire versions simplify wiring
Rugged case designed for very aggressive environments – cutting oils, grease, etc.
Pigtail connectors maintain the cutting oil enclosure rating while removing the connector
from the aggressive environment
Worry-free replacement: standard length, extended temperature and supply voltage range,
improved enclosure rating
Significant replacement time savings using patented plastic mounting bracket (no gauging)
or connectors
Trouble-free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Metal mounting lock nuts included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
See next page under specifications for LED function.
Connector is attached to an 0.8 meter (2.6 foot) pigtail cable.
With stainless steel mounting nuts and washers.
aTo order a normally closed (N.C.) version, change A to B, example; XS1M08PA370 to XS1M08PB370.
Nominal
Sensing
Distance
Circuit
Type
Output
Mode a
Voltage
Range
Max.
Load
Operating
Frequency
Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
Stainless steel case
Shielded, 2m (6.6’) cable
1.5 mm 2-wire N.O.a12-48 V 1.5-100 mA 4000 Hz A XS1M08DA210
1.5 mm PNP N.O.a12-48 V 200 mA 5000 Hz A XS1M08PA370
1.5 mm NPN N.O.a12-48 V 200 mA 5000 Hz A XS1M08NA370
1.5 mm PNP N.O. 12-48 V 200 mA 5000 Hz A XS1M08PA371
Shielded, connector - micro style DC
1.5 mm 2-wire N.O.a12-48 V 1.5-100 mA 4000 Hz B 11,12,15,16 XS1M08DA210D
1.5 mm 2-wire N.O.a12-48 V 1.5-100 mA 4000 Hz A 11,12,15,16 XS1M08DA210LD
1.5 mm PNP N.O.a12-48 V 200 mA 5000 Hz B 11,12,15,16 XS1M08PA370D
1.5 mm NPN N.O.a12-48 V 200 mA 5000 Hz B 11,12,15,16 XS1M08NA370D
1.5 mm 2-wire N.O. 12-48 V 1.5-100 mA 4000 Hz A 11,12,15,16 XS1M08DA214LD
Plastic case
Non-shielded, 2m (6.6’) cable
2.5 mm PNP N.O.a12-48 V 200 mA 5000 Hz A XS4P08PA370
2.5 mm NPN N.O.a12-48 V 200 mA 5000 Hz A XS4P08NA370
2.5 mm PNP N.O.+N.C.a12-24 V 200 mA 5000 Hz A XS4P08PC410
2.5 mm NPN N.O.+N.C.a12-24 V 200 mA 5000 Hz A XS4P08NC410
Nickel plated brass case, complementary N.O.+N.C. outputs
Shielded, 2m (6.6’) cable
1.5 mm PNP N.O.+N.C. 12-24 V 200 mA 5000 Hz A XS1M08PC410
1.5 mm NPN N.O.+N.C. 12-24 V 200 mA 5000 Hz A XS1M08NC410
Shielded, connector - micro style
1.5 mm PNP N.O.+N.C. 12-24 V 200 mA 5000 Hz B 11,12,15,16 XS1M08PC410D
1.5 mm NPN N.O.+N.C. 12-24 V 200 mA 5000 Hz B 11,12,15,16 XS1M08NC410D
Non-shielded, 2m (6.6’) cable
2.5 mm PNP N.O.+N.C. 12-24 V 200 mA 5000 Hz A XS2M08PC410
2.5 mm NPN N.O.+N.C. 12-24 V 200 mA 5000 Hz A XS2M08NC410
Non-shielded, connector - micro style
2.5 mm PNP N.O.+N.C. 12-24 V 200 mA 5000 Hz B 11,12,15,16 XS2M08PC410D
2.5 mm NPN N.O.+N.C. 12-24 V 200 mA 5000 Hz B 11,12,15,16 XS2M08NC410D
Minimum Mounting Clearances (mm/inches)
XS1Shielded e:3/.11 e:18/.71 e:4.5/.18 D:8/.31, H:0/0
XS2/XS4 Non-shielded e:10/.39 e:30/1.18 e:7.5/.30 D:24/.94, H:5/.20
LED
1.97
50
1.57
40
LED
1.97
50
1.57
40
2.40
61
LED
1.57
40
1.97
50
LED
1.57
40
LED
2.40
61
1.57
40
1.97
50
1.57
40
LED
LED
2.40
61
1.57
40
XS1M08kk210/410
XS1M08k370
XS1M08kk210D/410D
XSM08DA210LD
XS1M08k370D
XS2M08PC410
XS2M08NC410
XS2M08PC410D
XS2M08NC410D
Dual Dimensions inches
mm
thread
M8x1
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, DC; Universal Standard Length
229
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I nductive Sensors / 8 mm Diameter, DC; Universal Standard Length
Specifications
Note: Refer to page 351, for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded 0 to 1.2 mm
Non-shielded 0 to 2 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating -cable
(for connector, see page 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Enclosure material
Stainless Steel case stainless steel
Nickel plated Brass Case: Nickel plated Brass
Sensing face: PBT
Plastic PBT
Max. tightening torque
Stainless Steel 9 N•m (6.7 lb-ft)
Plastic 1 N•m (.74 lb-ft)
Nickel plated Brass 9 N•m
Vibration resistance
Shock resistance
(IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55Hz
(IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 8 mm x 8 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 2 or 3 wire 27AWG (0.11 mm2), PvR
Electrical
Voltage range – nominal 12 to 48 Vdc (12-24 complementary output)
Voltage limit (including ripple) 10 to 58 Vdc (10-38 complementary output)
Voltage drop (across
switch),closed state
2 wire 4 V
3 wire 2 V
Maximum load current
2 wire 1.5-100 mA
3 wire 100 mA
4 wire complementary output 200 mA
Current consumption
(no load) 3 wire 10 mA
Residual (leakage) current, open state, 2 wire 0.6 mA
On delay (max.) 2 wire 0.2 ms
3 wire 0.1 ms
Off delay (max.) 2 wire 0.2 ms
3 wire 0.1 ms
Power-up delay (max.) 2 wire 5 ms
3 wire 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity
(RFI) IEC 61000-4-3 L3
Electrostatic; transients;
impulse
2 wire IEC 61000-4-2 L3, IEC 61000-4-4 L4; 60947.5.2 L2
3 wire IEC 61000-4-2 L2, IEC 61000-4-4 L3; 60947.5.2 L2
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE208
Metal mounting nuts and lock washers XSZE108
Mounting bracket, plastic XSZB108
Mounting bracket, diecast zinc 8316 08
Stainless steel mounting nuts XSZE208
Stainless steel lock washers XSZE908
F
or additional cable options and lengths see p. 518
A
ccessories . . . . . . . . . . . . . . . . . . . . .page 298, 317
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk 8316kk
W
iring
Connector M12 Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
3 wire NO or NC
wire color/connector pin
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
BN/3 +/-
-/+
2 wire, non-polarized
BU/4
NC WH/2
BK/4
BN/1
BU/3
+
-
PNP
NO
4 wire NO + NC
NC WH/2
BK/4
BN/1
BU/3
+
-
NPN
NO
®
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, AC/DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
230 10/02
Proximity Sensors
XS Tubular, I nductive Sensors / 8 mm Diameter, AC/DC; Universal Standard Length
Features
Faster troubleshooting aided by high visibility 360° indicator
Rugged case designed for aggressive environments.
Worry-free replacement: standard length, extended temperature range, AC or DC power
supply
Significant replacement time savings using patented plastic mounting bracket (no gauging)
or connectors
Trouble-free operation ensured by extensive protective circuitry
Normally closed (N.C.) output available on versions markeda
Plastic mounting nuts for plastic and lock nuts for metal housing included
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version, change A to B, example; XS1M08MA230 to XS1M08MB230.
Nominal
Sensing
Distance
Output
Mode
Voltage Range Operating Frequency Indicator
LED (see
next page)
Mating
Connector Style
(see p. 518)
Catalog
Number
AC DC AC DC
Nickel plated brass case
Shielded, 2m (6.6’) cable
1.5 mm N.O.a24-240 V 24-210 V 25 Hz 4000 Hz A XS1M08MA230
Shielded, connector - micro style AC
1.5 mm N.O.a24-240 V 24-210 V 25 Hz 4000 Hz B 17,18 XS1M08MA230K
Non-shielded, 2m (6.6’) cable
2.5 mm N.O.a24-240 V 24-210 V 25 Hz 3000 Hz A XS2M08MA230
Non-shielded, connector - micro style AC
2.5 mm N.O.a24-240 V 24-210 V 25 Hz 3000 Hz B 17,18 XS2M08MA230K
Plastic case
Non-shielded, 2m (6.6’) cable
2.5 mm N.O.a24-240 V 24-210 V 25 Hz 3000 Hz A XS4P08MA230
Non-shielded, connector - micro style AC
2.5 mm N.O.a24-240 V 24-210 V 25 Hz 3000 Hz A 17,18 XS4P08MA230K
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e:3/.12 e:18/.71 e:4.5/.18 D:8/.31, H:0/0
XS2/XS4 Non-shielded e:10/.39 e:30/1.18 e:7.5/.30 D:24/.94, H:5/.20
LED
LED
LED
LED
LED
LED
61
2.40
40
1.57
50
1.97
40
1.57
57
2.42
36
1.41
46
1.81
36
1.41
4
4
.15
.15 61
2.40
40
1.57
50
1.97
40
1.57
XS1M08k230
XS1M08k230K
XS2M08k230
XS2M08k230K
XS4P08k230
XS2P08k230K
Dual Dimensions inches
mm
thread
M8x1
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
Proximity Sensors
XS Tubular, Inductive Sensors
8 mm Diameter, AC/DC; Universal Standard Length
231
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I nductive Sensors / 8 mm Diameter, AC/DC; Universal Standard Length
Specifications
Note: Refer to p. 351, for target material correction coefficient Km.
aSee p. 298 for protective fuses.
Mechanical
Usable sensing range Shielded 0 to 1.2 mm
Non-shielded 0 to 2 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see page 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Enclosure material Nickel plated brass Case: Nickel plated Brass
Sensing face: PBT
Plastic PBT
Tightening torque (max.) Nickel plated brass 9 N•m (79.6 lb-ft)
Plastic 1 N•m (.74 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz
Shock resistance (IEC60068.2.27) 50 G duration 11 ms
Standard target size (steel) 8 mm x 8 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
BOne LED visible from 4 quadrants: Shows
output status
Cable 2 wire 27 AWG (0.11 mm2), PvR
Electrical
Voltage range 24 to 240 Vac (50/60 Hz), 24 to 210 Vdc
Voltage limit (including ripple) 20 to 264 Vac/Vdc
Maximum Voltage drop (across switch), closed state 5.5V
Inrush current (inductive @ 20ms) 2A
Minimum load current 5 mA
Maximum load current
100 mA
20 Vdc 58 IEC 60947-5-2 Utilization category DC-13
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Residual (leakage) current,
open state
24 Vac/Vdc 0.8 mA
120 Vac/Vdc 1.5 mA
On delay (max.) .2 ms
Off delay (max.) .2 ms
Power-up delay (max.) 40 ms
Protective circuitry
Short circuit protection Noa
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE208
Metal mounting lock nuts XSZE108
Mounting bracket, plastic XSZB108
Mounting bracket, diecast zinc 831608
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . . . . page 298
Connector Cables (U20 or K suffix)
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk 8316kk
Wiring
Connector 0.5" 20-UNF Cable
Blue BU –
Brown BN +
Black BK Output
1
32
wire color/connector pin
2 wire, AC/DC for connector version only
BN/2 L1 +/-
L2 -/+
BU/3
AC/DC
®
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, DC; Economy Short Length
©1997- 2002 Schneider Electric All Rights Reserved
232 10/02
Proximity Sensors
XS Tubular, I nductive Sensors / 12 mm Diameter, DC; Economy Short Length
Features
See X dimension below.
aTo order a normally closed (N.C.) version, change A to B, example; XS1M08MA230 to XS1M08MB230.
360° LED indicators
Extended range models
Complementary N.O. + N.C. models
Rugged metal or plastic cases
Patented plastic mounting bracket
Connector options
Extensive protective circuitry
Works with unregulated DC supply powered by
24 V secondary transformer
Metal lock nuts or plastic mounting nuts included
Normally closed (N.C.) output available on versions
marked a
UL Listed, CSA Certified and CE Mark
Nominal Sensing
Distance
Circuit
Type
Volt age
Range
Output
Mode
Operating
Frequency
Indicator LED
(see next page)
Mating Connector
Style (see p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
2 mm PNP 12-24 V N.O.a5000 Hz A XS1N12PA340
2 mm NPN 12-24 V N.O.a5000 Hz A XS1N12NA340
2 mm PNP 12-24 V N.O. + N.C. 5000 Hz A XS1N12PC410
2 mm NPN 12-24 V N.O. + N.C. 5000 Hz A XS1N12NC410
Shielded, connector - micro style
2 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS1N12PA340D
2 mm NPN 12-24 V N.O. 5000 Hz B 11,12,14,15,16 XS1N12NA340D
2 mm PNP 12-24 V N.O. + N.C. 5000 Hz B 11,12,13,15,16 XS1N12PC410D
2 mm NPN 12-24 V N.O. + N.C. 5000 Hz B 11,12,14,15,16 XS1N12NC410D
Shielded, EXTENDED RANGE 2 m (6.6’) cable
4 mm PNP 12-24 V N.O.a2500 Hz A XS1N12PA349
4 mm NPN 12-24 V N.O.a2500 Hz A XS1N12NA349
Shielded, EXTENDED RANGE connector - micro style DC
4 mm PNP 12-24 V N.O.a2500 Hz B 11,12,13,15,16 XS1N12PA349D
4 mm NPN 12-24 V N.O.a2500 Hz B 11,12,14,15,16 XS1N12NA349D
Non-shielded, 2 m (6.6’) cable
4 mm PNP 12-24 V N.O. 5000 Hz A XS2N12PA340
4 mm NPN 12-24 V N.O. 5000 Hz A XS2N12NA340
4 mm PNP 12-24 V N.O. + N.C. 5000 Hz A XS2N12PC410
4 mm NPN 12-24 V N.O. + N.C. 5000 Hz A XS2N12NC410
Non-shielded, connector - micro style DC
4 mm PNP 12-24 V N.O.a5000 Hz B 11,12,13,15,16 XS2N12PA340D
4 mm NPN 12-24 V N.O.a5000 Hz B 11,12,14,15,16 XS2N12NA340D
4 mm PNP 12-24 V N.O. + N.C. 5000 Hz B 11,12,13,15,16 XS2N12PC410D
4 mm NPN 12-24 V N.O. + N.C. 5000 Hz B 11,12,14,15,16 XS2N12NC410D
Plastic case
Non-shielded, 2 m (6.6’) cable
4 mm PNP 12-24 V N.O.a5000 Hz A XS4P12PA340
4 mm NPN 12-24 V N.O.a5000 Hz A XS4P12NA340
4 mm PNP 12-24 V N.O. + N.C. 5000 Hz A XS4P12PC410
4 mm NPN 12-24 V N.O. + N.C. 5000 Hz A XS4P12NC410
Non-shielded, connector - micro style DC
4 mm PNP 12-24 V N.O.a5000 Hz A 11,12,13,15,16 XS4P12PA340D
4 mm NPN 12-24 V N.O.a5000 Hz A 11,12,14,15,16 XS4P12NA340D
4 mm PNP 12-24 V N.O. + N.C. 5000 Hz A 11,12,13,15,16 XS4P12PC410D
4 mm NPN 12-24 V N.O. + N.C. 5000 Hz A 11,12,14,15,16 XS4P12NC410D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 4/.16 e: 24/.94 e: 6/.24 D: 12/.47 x: 0/0
XS1 Extended range e: 8/.31 e: 48/1.89 e: 12/.47 D: 12/.47 D: 12/.47, x: 2.4/.09
XS2/XS4 Non-shielded e: 16/.63 e: 48/1.89 e: 12/.47 D: 36/1.42, H: 8/.31 D: 12/.47, x: 2.4/.09
LED
LED
LED
LED
LED
LED
LED
LED
45
1.77
27
1.06
40
1.57
20
.78
33
1.30
26
1.02
28
1.10
21
.82
5
5
.19
.19
45
1.77
25
.98 33
1.30
26
1.02
45
1.77
25
.98 33
1.30
26
1.02
XS1N12k
XS1N12kD
XS1N12k349
XS1N12k349D
XS2N12k
XS2N12kD
XS4P12k
XS4P12kD
Dual Dimensions inches
mm
thread
M12x1
Mounting in a metal support
D
H
Facing a metal object
e
Side by side
e
Face to face
e
Mounted in a metal support
DX
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, DC; Economy Short Length
233
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I nductive Sensors / 12 mm Diameter, DC; Economy Short Length
Specifications
Note: Refer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded Standard Range 0 to 1.6 mm
Extended Range 0 to 3.2 mm
Non-shielded 0 to 3.2 mm
Standard temperature range Ni plated brass -25° C to +70° C (-13° F to +158° F)
Plastic -25° C to +80° C (-13° F to +176° F)
Extended range -25° C to +50° C (-13° F to +122° F)
Enclosure rating - cable
(for connector see page 518)
Nickel plated brass NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Plastic case NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68
Enclosure material Nickel plated brass Case Nickel plated brass
Sensing face PBT
Plastic case PBT
Tightening torque (max.) Nickel plated brass 6 N•m (4.4 lb-ft)
Plastic 2 N•m (1.5 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f=10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 12 mm x 12 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 3 wire 22 AWG (0.34 mm2), PvR
4 wire (N.O. + N.C.) 21 AWG (0.22 mm2), PvR
Electrical
Voltage range – nominal 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch), closed state 2V
Maximum load current 200 mA
Current consumption (no load) 10 mA
On delay (max.) Standard Range 0.1 ms
Extended Range 0.2 ms
Off delay (max.) Standard Range 0.1 ms
Extended Range 0.2 ms
Power-up delay (max.) Standard/Extended Range 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 L3
Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE212
Metal mounting nuts XSZE112
Mounting bracket 90° steel 9006PA12
Mounting bracket, plastic XSZB112
Mounting bracket, diecast zinc 831612
0.5" NPT conduit adapter length: 2" (50.8mm) Aluminum 74281
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk 8316kk
9006PAkk
74281
Wiring
Connector M12 Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC
BK/2 NC
NO
3 wire NO or NC
wire color/connector pin
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
NC WH/2
BK/4
BN/1
BU/3
+
-
PNP NO
4 wire NO + NC
NC WH/2
BK/4
BN/1
BU/3
+
-
NPN NO
BK/4 NO
®
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
234 10/02
Proximity Sensors
XS Tubular, Inductive Sensors / 12 mm Diame ter, DC; Univ ersal Standard L ength
Features
Faster troubleshooting aided by high visibility 360° indicators
2 wire versions simplify wiring
Rugged case designed for aggressive environments
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./
N.C. output circuit.
Significant replacement time savings using patented plastic mounting bracket (no gauging)
or connectors
Pigtail connectors, version (0.8m/2.6' cable) provide cutting oil (IP68) rating and connection
for aggressive environments
Trouble free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Metal mounting lock nuts included
Normally closed (N.C.) output available on versions (marked a)
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M12PA370 to XS1M12PB370.
See next page under specifications for LED function.
Nominal Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Max.
Load
Operating
Frequency
Indicator
LED
Mating Connector
Style (see p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
2 mm 2-wire 12-48 V N.O. a1.5-100 mA 4000 Hz A XS1M12DA210
2 mm PNP 12-48 V N.O.a200 mA 5000 Hz A XS1M12PA370
2 mm NPN 12-48 V N.O.a200 mA 5000 Hz A XS1M12NA370
2 mm PNP/NPN 12-24V N.O./N.C. 200 mA 5000 Hz A XS1M12KP340
Shielded, connector - micro style DC
2 mm 2-wire 12-48 V N.O. a1.5-100 mA 4000 Hz B 11,12,15,16 XS1M12DA210D
2 mm PNP 12-48 V N.O.a200 mA 5000 Hz B 11,12,13,15,16 XS1M12PA370D
2 mm NPN 12-48 V N.O.a200 mA 5000 Hz B 11,12,14,15,16 XS1M12NA370D
2 mm PNP/NPN 12-24V N.O./N.C. 200 mA 5000 Hz B 11,12,15,16 XS1M12KP340D
Shielded, connector - micro style DC - 0.8 m (2.6 ft) pigtail
2 mm 2-wire 12-48 V N.O. a1.5-100 mA 4000 Hz A 9,10,11,12,15,16 XS1M12DA210LD
Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail
2 mm 2-wire 12-48 V N.O.a1.5-100 mA 4000 Hz A 21,22 XS1M12DA210LA
Non-shielded, 2 m (6.6’) cable
4 mm PNP 12-48 V N.O.a200 mA 5000 Hz A XS2M12PA370
4 mm NPN 12-48 V N.O.a200 mA 5000 Hz A XS2M12NA370
4 mm PNP + NPN 12-24V N.O./N.C. 200 mA 5000 Hz A XS2M12KP340
Non-shielded, connector - micro style D
4 mm PNP 12-48 V N.O.a200 mA 5000 Hz B 11,12,13,15,16 XS2M12PA370D
4 mm NPN 12-48 V N.O.a200 mA 5000 Hz B 11,12,14,15,16 XS2M12NA370D
4 mm PNP + NPN 12-24V N.O./N.C. 200 mA 5000 Hz B 11,12,15,16 XS2M12KP340D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 4/.16 e: 24/.94 e: 6/.24 D: 12/.47, H: 0/0
XS2 Non-shielded e: 16/.63 e: 48/1.89 e: 12/.47 D: 36/1.42, H: 8/.31
1.97
50
1.65
42
LED
2.40
61
1.57
40
LED
1.77
45
.19
5
1.45
37
LED
2.20
56
.19
5
1.37
35
LED
1.97
50
1.65
42
LED
LED
1.97
50
1.65
42
XS1k210/340/370
Dual Dimensions inches
mm
XS1k210/
340/370D
XS1kDA210LD
XS1kDA210LA
XS2k370
XS2k370D
thread
M12x1
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, DC; Universal Standard Length
235
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I nductive Sensors / 12 mm Diameter, DC; Universal Standard Length
Specifications
aRefer to page 351 for target material correction coefficient Km.
Mechanical
Usable sensing range aShielded 0 to 1.6 mm
Non-shielded 0 to 3.2 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68 – cutting oil proof
Enclosure material Nickel plated brass Case Nickel plated Brass
Sensing face PBT
Tightening torque (max.) Nickel plated brass 15 N•m (11 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 12 mm x 12 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
BOne LED visible from 4 quadrants: Shows
output status
Cable 2 or 3 wire 22 AWG (0.34 mm2), PvR
Electrical Std KP Models
Voltage range – nominal 12 to 48 Vdc 12 to 24 Vdc
Voltage limit (including ripple) 10 to 58 Vdc 10 to 38 Vdc
Voltage drop (across
switch), closed state
3 wire 2 V 2.6 V
2 wire 4 V
Minimum load current 2 wire 1.5 mA
Maximum load current 2 wire 100 mA
3 wire 200 mA
Current consumption
(no load)
2 wire
3 wire 10 mA
Residual (leakage) current, open state 2 wire 0.5 mA
On delay (max.) 2 wire 0.2 ms
3 wire 0.1 ms
Off delay (max.) 2 wire 0.2 ms
3 wire 0.1 ms
Power-up delay (max.) 2 wire 5 ms
3 wire 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse
(L - indicates level number)
2 wire: IEC 61000-4-2 L3; IEC 61000-4-4
L3;60947.5.2 L3
3 wire: IEC 61000-4-2 L2; IEC 61000-4-4
L3;60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE212
Metal mounting lock nuts XSZE112
Mounting bracket, 90° steel 9006PA12
Mounting bracket, plastic XSZB112
Mounting bracket, diecast zinc 831612
0.5" NPT conduit adapter length 2" (50.8mm) Aluminum 74281
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA101Y Micro Conn., 3 pin, 2 m, straight
XSZCA111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk 8316kk
9006PAkk
74281
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
13
2
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
BK/4
WH/2
BK/4
WH/2
BN/1 (NO),BU/3 (NC)
BU/3 (NO),BU/1 (NC)
+
-
PNP
BU/3 (NO),BU/1 (NC)
+
-
NPN
BN/1 (NO),BU/3 (NC)
3 wire, selectable PNP/NPN, NO/NC
4 wire, programmable, NO or NC output
2 wire non-polarized
BN/3 +/-
-/+
BU/4
®
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, DC; Universal Standard Length, Non-corrosive
©1997- 2002 Schneider Electric All Rights Reserved
236 10/02
Proximity Sensors
XS Tubular, Inductive Sensors / 12 mm Diame ter, DC; Univ ersal Standard L ength, Non-corrosive
Features
Faster troubleshooting aided by high visibility 360° indicators
2 wire versions simplify wiring
High impact stainless steel and plastic cases for aggressive environments - cutting oils,
grease, solvents, etc.
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./
N.C. output circuit
Significant replacement time savings using patented plastic mounting bracket (no gauging)
or connectors
Pigtail connector version (0.8 m /2.6 ' cable) provides cutting oil (IP68) rating and connection
for aggressive environments.
Trouble free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Stainless steel lock nuts for metal or plastic mounting nuts for plastic housings included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M12PA371 to XS1M12PB371.
See next page under specifications for LED function.
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Max.
Load
Operating
Frequency
Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
Stainless steel case
Shielded, 2m (6.6’) cable
2 mm 2-wire 12-48 V N.O. 1.5-100 mA 4000 Hz A XS1M12DA211
2 mm PNP 12-48 V N.O. 200 mA 5000 Hz A XS1M12PA371
2 mm NPN 12-48 V N.O. 200 mA 5000 Hz A XS1M12NA371
Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail
2 mm 2-wire 12-48 V N.O. 1.5-100 mA 4000 Hz A 21,22 XS1M12DA211LA
Non-shielded, 2m (6.6’) cable
4 mm PNP 12-48 V N.O. 200 mA 5000 Hz A XS2M12PA371
4 mm NPN 12-48 V N.O. 200 mA 5000 Hz A XS2M12NA371
Plastic case
Non-shielded, 2m (6.6’) cable
4 mm PNP 12-48 V N.O.a200 mA 5000 Hz A XS4P12PA370
4 mm NPN 12-48 V N.O.a200 mA 5000 Hz A XS4P12NA370
4 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 5000 Hz A XS4P12KP340
Non-shielded, connector - micro style DC
4 mm PNP 12-48 V N.O.a200 mA 5000 Hz A 11,12,13,15,16 XS4P12PA370D
4 mm NPN 12-48 V N.O.a200 mA 5000 Hz A 11,12,14,15,16 XS4P12NA370D
4 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 5000 Hz A 11,12,15,16 XS4P12KP340D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 4/.16 e: 24/.94 e: 6/.24 D: 12/.47, H: 0/0
XS2/XS4 Non-shielded e: 16/.63 e: 48/1.89 e: 12/.47 D: 36/1.42, H: 8/.31
LED
LED
LED
LED
LED
61
2.40
42
1,65
50
1.97
42
1.65 45
1.77
37
1.45
5
.19
50
1.97 42
1.65
50
1.97
42
1.65
Dual Dimensions inches
mm
XS1M12k370/371
XS1M12DA211LA
XS2M12k370/371
XS1P12k370
XS4P12k370D
thread
M12x1
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, DC; Universal Standard Length, Non-corrosive
237
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I Nductive Sensors / 12 mm Diameter, DC; Universal Standard Length, Non-corrosive
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded 0 to 1.6 mm
Non-shielded 0 to 3.2 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable NEMA Type 3, 4X, 6P, 12, 13
(for connector, see p. 518) IEC Type IP68
Enclosure material
Stainless steel case #303 Stainless steel
Sensing face PBT
Plastic PBT
Tightening torque (max.) Stainless steel 30 N•m (22 lb-ft)
Plastic 2 N•m (1.5 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11ms
Standard target size (steel) 12 mm x 12 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
Cable 2 or 3 wire 22 AWG (0.34 mm2), PvR
Electrical Standard KP-Models
Voltage range – nominal 12 to 48 Vdc 12 to 24 Vdc
Voltage limit (including ripple) 10 to 58 Vdc 10 to 38 Vdc
Voltage drop (across
switch), closed state
3 wire 2 V 2.6V
2 wire 4 V
Minimum load current 2 wire 1.5 mA
Maximum load current 2 wire 100 mA
3 wire 200 mA
Current consumption
(no load) 3 wire 10 mA
Residual (leakage) current, open state 2 wire 0.6 mA
On delay (max.) 2 wire 0.5 ms
3 wire 0.1 ms
Off delay (max.) 2 wire 0.5 ms
3 wire 0.1 ms
Power-up delay (max.) 2 wire 5 ms
3 wire 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse
(L - indicates level number)
2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3
3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE212
Stainless steel mounting nuts XSZE312
Locknut washers, stainless steel XSZE912
Mounting bracket, 90° steel 9006PA12
Mounting bracket, plastic XSZB112
Mounting bracket, diecast zinc 831612
0.5" NPT conduit adapter length 2" (50.8mm) Aluminum 74281
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA101Y Mini Conn., 3 pin, 2 m, straight
XSZCA111Y Mini Conn., 3 pin, 2 m, 90°
XSZB1kk 8316kk
9006PAkk
74281
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
13
2
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
BK/4
WH/2
BK/4
WH/2
BN/1 (NO),BU/3 (NC)
BU/3 (NO),BU/1 (NC)
+
-
PNP
BU/3 (NO),BU/1 (NC)
+
-
NPN
BN/1 (NO),BU/3 (NC)
3 wire, selectable PNP/NPN, NO/NC
4 wire, programmable, NO or NC output
2 wire non-polarized
BN/3 +/-
-/+
BU/4
®
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, AC/DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
238 10/02
Proximity Sensors
XS Tubular, I Nductive Sensors / 12 mm Diameter, AC/DC; Universal Standard Length
Features
Faster troubleshooting aided by high visibility 360° indicators
Rugged metal or plastic cases designed for aggressive environments - cutting oils, grease,
etc.
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68), AC/DC power supply
Significant replacement time savings using patented plastic mounting bracket
(no gauging) or connectors
Metal locking nuts for metal or plastic mounting nuts for plastic housings included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M12PA260 to XS1M12PB260.
See next page under specifications for LED function.
Nominal
Sensing
Distance
AC or
AC/DC
Output
Modea
Volt age Range Operating
Frequency SCP Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
AC DC AC DC
Nickel plated brass case
Shielded, 2 m (6.6’) cable
2 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 4000 Hz no A XS1M12MA230
2 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 4000 Hz yes A XS1M12MA250
Shielded, connector - micro style AC
2 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 4000 Hz no B 17,18 XS1M12MA230K
Non-shielded, 2 m (6.6’) cable
4 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no A XS2M12MA230
4 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz yes A XS2M12MA250
Non-shielded, connector - micro style AC
4 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no B 17,18 XS2M12MA230K
Plastic case
Non-shielded, 2 m (6.6’) cable
4 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 4000 Hz no A XS4P12MA230
Non-shielded, connector - micro style
4 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no A 17,18 XS4P12MA230K
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 4/.16 e: 24/.94 e: 6/.24 D: 12/.47, H: 0/0
XS2/XS4 Non-shielded e: 16/.63 e: 48/1.89 e: 12/.47 D: 36/1.42, H: 8/.31
1.97
50
1.65
42
LED
2.40
61
1.57
40
LED
.19
5
1.77
45
1.45
37
LED
.19
5
2.20
56
1.37
35
LED
2.40
61
1.65
42
LED
LED
1.65
42
1.97
50
Dual Dimensions inches
mm
XS1Mk
XS1MkK
XS2Mk
XS2MkK
XS3/XS4Pk
XS4PkK
thread
M12x1
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
Proximity Sensors
XS Tubular, Inductive Sensors
12 mm Diameter, AC/DC; Universal Standard Length
239
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular, I nductive Sensors / 12 mm Diameter, AC/DC; Universal Standard Length
Specifications
aRefer to p. 351 for target material correction coefficient Km.
qFor devices without SCP, see p. 298 for protective fuses.
Mechanical
Usable sensing rangeaShielded 0 to 1.6 mm
Non-shielded 0 to 3.2 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68
Enclosure material
Nickel plated brass case Nickel plated Brass
Sensing face PBT
Plastic case PBT
Tightening torque (max.) Nickel plated brass 15 N•m (11 lb-ft)
Plastic 2 N•m (1.5 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) 12 mm x 12 mm
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 2 wire 22 AWG (0.34 mm2), PvR
Electrical
Voltage range 24 to 240 Vac (50/60 Hz), 24 to 210 Vdc
Voltage limit (including ripple) 20 to 264 Vac/Vdc
Maximum Voltage drop (across switch), closed state 5.5V
Inrush current (inductive @ 20ms) 2A
Minimum load current 5 mA
Maximum load current
200 mA
20 Vdc 58 IEC 60947-5-2 Utilization category DC-13
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Residual (leakage) current, open state 0.6 mA
On delay (max.) 0.2 ms
Off delay (max.) 0.2 ms
Power-up delay (max.) Without SCP 40 ms
With SCP 70 ms
Protective circuitry
Short circuit protection Optionalq
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse (L - level number) IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3
Agency Listings E164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE212
Metal mounting nuts and lock washers XSZE112
Mounting bracket, 90° steel 9006PA12
Mounting bracket, plastic XSZB112
Mounting bracket, diecast zinc 831612
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 74281
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (U20 or K suffix)
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk 8316kk
9006PAkk
74281
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
1
3
2
wire color/connector pin
2 wire, AC/DC for connector version only
BN/2 L1 +/-
L2 -/+
BU/3
AC/DC
®
Proximity Sensors
XS Tubular, Inductive Sensors
18 mm Diameter, DC; Economy Short Length
©1997- 2002 Schneider Electric All Rights Reserved
240 10/02
Proximity Sensors
XS Tubular, I nductive Sensors / 18 mm Diameter, DC; Economy Short Length
Features
aTo order a normally closed (N.C.) version change the A to B, example: XS1N18PA340 to XS1N18PB340.
See next page under specifications for LED function.
See dimension X below.
360° LED indicators
Extended range models
Complementary N.O. + N.C. models
Rugged metal or plastic cases
Patented plastic mounting bracket
Connector options
Extensive protective circuitry
Works with unregulated DC supply powered by
24 V secondary transformer
Metal locknuts or plastic mounting nuts included
Normally closed (N.C.) output available on versions
markeda
UL Listed, CSA Certified and CE Mark
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Operating
Frequency
Indicator
LED
Mating Connector
Style (see p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
5 mm PNP 10-38 V N.O.a2000 Hz A XS1N18PA340
5 mm NPN 10-38 V N.O.a2000 Hz A XS1N18NA340
5 mm PNP 10-38 V N.O. + N.C. 2000 Hz A XS1N18PC410
5 mm NPN 10-38 V N.O. + N.C. 2000 Hz A XS1N18NC410
Shielded, connector - micro style DC
5 mm PNP 10-38 V N.O. 2000 Hz B 11,12,13,15,16 XS1N18PA340D
5 mm NPN 10-38 V N.O. 2000 Hz B 11,12,14,15,16 XS1N18NA340D
5 mm PNP 10-38 V N.O. + N.C. 2000 Hz B 11,12,13,15,16 XS1N18PC410D
5 mm NPN 10-38 V N.O. + N.C. 2000 Hz B 11,12,14,15,16 XS1N18NC410D
Shielded, EXTENDED RANGE, 2 m (6.6’) cable
10 mm PNP 10-38 V N.O. a1000 Hz A XS1N18PA349
10 mm NPN 10-38 V N.O.a1000 Hz A XS1N18NA349
Shielded, EXTENDED RANGE, connector - micro style
10 mm PNP 10-38 V N.O.a1000 Hz B 11,12,13,15,16 XS1N18PA349D
10 mm NPN 10-38 V N.O.a1000 Hz B 11,12,14,15,16 XS1N18NA349D
Non-shielded, 2 m (6.6’) cable
8 mm PNP 10-38 V N.O. 2000 Hz A XS2N18PA340
8 mm NPN 10-38 V N.O. 2000 Hz A XS2N18NA340
8 mm PNP 10-38 V N.O. + N.C. 2000 Hz A XS2N18PC410
8 mm NPN 10-38 V N.O. + N.C. 2000 Hz A XS2N18NC410
Non-shielded, connector - micro style
8 mm PNP 10-38 V N.O. 2000 Hz B 11,12,13,15,16 XS2N18PA340D
8 mm NPN 10-38 V N.O. 2000 Hz B 11,12,14,15,16 XS2N18NA340D
8 mm PNP 10-38 V N.O. + N.C. 2000 Hz B 11,12,13,15,16 XS2N18PC410D
8 mm NPN 10-38 V N.O. + N.C. 2000 Hz B 11,12,14,15,16 XS2N18NC410D
Plastic case
Non-shielded, 2 m (6.6’) cable
8 mm PNP 10-38 V N.O.a2000 Hz A XS4P18PA340
8 mm NPN 10-38 V N.O.a2000 Hz A XS4P18NA340
8 mm PNP 10-38 V N.O. + N.C. 2000 Hz A XS4P18PC410
8 mm NPN 10-38 V N.O. + N.C. 2000 Hz A XS4P18NC410
Non-shielded, connector - micro style
8 mm PNP 10-38 V N.O.a2000 Hz A 11,12,13,15,16 XS4P18PA340D
8 mm NPN 10-38 V N.O.a2000 Hz A 11,12,14,15,16 XS4P18NA340D
8 mm PNP 10-38 V N.O. + N.C. 2000 Hz A 11,12,13,15,16 XS4P18PC410D
8 mm NPN 10-38 V N.O. + N.C. 2000 Hz A 11,12,14,15,16 XS4P18NC410D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0 D: 18/.70
XS1 Extended range e: 20/.79 e: 96/3.78 e: 24/.94 D: 18/.71, x: 3.6/.14
XS2/XS4 Non-shielded e: 16/.63 e: 96/3.78 e: 24/.94 D: 54/2.13, H: 16/.63
1.31
33.5
1.02
26
LED
1.77
45
1.02
26
LED
1.31
33.5
1.02
26
LED
1.02
26
LED
1.77
45
.31
8
.88
22.5
.70
18
LED
1.45
37
LED
.70
18
.31
8
LED
1.02
26
1.31
33.5
1.77
45
1.14
29
LED
Dual Dimensions inches
mm
XS1k340/410
XS1k340/410D
XS1k349
XS1k349D
XS2k340/410
XS2kD
XS4k340/410
XS4kD
thread
M18x1
Mounting in a metal support
D
H
Facing a metal object
e
Side by side
e
Face to face
e
Mounted in a metal support
DX
Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, DC; Economy Short Length
241
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, DC; Econ omy Short Length
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded Standard Range 0 to 4 mm
Extended Range 0 to 8 mm
Non-shielded 0 to 6.4 mm
Standard temperature range Nickel plated brass -25° C to +70° C (-13° F to +158° F)
Plastic -25° C to +80° C (-13° F to +176° F)
Extended range -25° C to +50° C (-13° F to +122° F)
Enclosure rating - cable
for connector, see p. 518
Nickel plated brass NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Plastic NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68
Enclosure material
Nickel plated brass Case Nickel plated brass
Sensing face PBT
Plastic Case PBT
Sensing face PBT
Tightening torque (max.) Nickel plated brass 15 N•m (11 lb-ft)
Plastic 5 N•m (3.7 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded Standard range 0.7" x 0.7" (18 mm x 18 mm)
Extended range 1.18" x 1.18" (30 mm x 30 mm)
Unshielded 0.94" x 0.94" (24 mm x 24 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
BOne LED visible from 4 quadrants: Shows output
status
Cable 3 or 4 wire 22 AWG (0.34 mm2), PvR
Electrical
Voltage range – nominal 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch), closed state 2 V
Maximum load current 200 mA
Current consumption (no load) 10 mA
On delay (max.) 0.15 ms
Off delay (max.) 0.35 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Extended range: IEC 61000-4-4 L3
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type and standard sensing distance only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE218
Metal mounting nuts and lock washer XSZE118
Mounting bracket 90° steel 9006PA18
Mounting bracket, plastic, long length XSZB118
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 7428
Stainless 74282
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298. 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
9006PAkk
74281
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
NC WH/2
BK/4
BN/1
BU/3
+
-
PNP NO
4 wire NO + NC
NC WH/2
BK/4
BN/1
BU/3
+
-
NPN NO
®
Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
242 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, DC; Univers al Standard Leng th
Features
Faster troubleshooting aided by high visibility 360° indicators
2 wire versions simplify wiring
Rugged case designed for aggressive industrial environments
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./
N.C. output circuit
Significant replacement time savings using patented plastic mounting bracket
(no gauging) or connectors
Trouble free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Pigtail connector version (0.8 m/2.6' cable) provides cutting oil (IP68) ratings and
connection for aggressive environments. Screw terminals models for wiring special cables.
Metal mounting lock nuts included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M18PA370 to XS1M18PB370.
See next page under specifications for LED function.
Nickel plated brass case
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Max.
Load
Operating
Frequency
Indicator
LED
Mating Connector
Style (see p. 518)
Catalog
Number
Shielded, 2m (6.6’) cable
5 mm 2-wire 12-48 V N.O.a1.5-100 mA 3000 Hz A XS1M18DA210
5 mm PNP 12-48 V N.O.a200 mA 2000 Hz A XS1M18PA370
5 mm NPN 12-48 V N.O.a200 mA 2000 Hz A XS1M18NA370
5 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 2000 Hz A XS1M18KP340
Shielded connector - micro style DC - 0.8 m (2.6 ft) pigtail
5 mm 2-wire 12-48 V N.O.a1.5-100 mA 3000 Hz A 11,12,15,16 XS1M18DA210LD
Shielded, connector - micro style DC
5 mm 2-wire 12-48 V N.O.a1.5-100 mA 3000 Hz B 11,12,15,16 XS1M18DA210D
5 mm PNP 12-48 V N.O.a200 mA 2000 Hz B 11,12,13,15,16 XS1M18PA370D
5 mm NPN 12-48 V N.O.a200 mA 2000 Hz B 11,12,14,15,16 XS1M18NA370D
5 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 2000 Hz B 11,12,15,16 XS1M18KP340D
Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail
5 mm 2-wire 12-48 V N.O.a1.5-100 mA 3000 Hz A 21,22 XS1M18DA210LA
Shielded, connector - mini style 3 PIN
5 mm PNP 12-48 V N.O.a200 mA 2000 Hz B 21,22 XS1M18PA370A
5 mm NPN 12-48 V N.O.a200 mA 2000 Hz B 21,22 XS1M18NA370A
Shielded, screw terminal connection
5 mm 2 wire 12-48 V N.O.a1.5-100mA 3000 Hz B XS1M18DA210B
5 mm PNP 12-48 V N.O.a200 mA 2000 Hz B XS1M18PA370B
5 mm NPN 12-48 V N.O.a200 mA 2000 Hz B XS1M18NA370B
Non-shielded, 2m (6.6’) cable
8 mm PNP 12-48 V N.O.a200 mA 2000 Hz A XS2M18PA370
8 mm NPN 12-48 V N.O.a200 mA 2000 Hz A XS2M18NA370
8 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 2000 Hz A XS2M18KP340
Non-shielded, connector - micro style
8 mm PNP 12-48 V N.O.a200 mA 2000 Hz B 11,12,13,15,16 XS2M18PA370D
8 mm NPN 12-48 V N.O.a200 mA 2000 Hz B 11,12,14,15,16 XS2M18NA370D
8 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 2000 Hz B 11,12,15,16 XS2M18KP340D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0
XS2 Non-shielded e: 16/.63 e: 96/3.78 e: 24/.94 D: 54/2.13, H: 8/.31
2.44
62
1.17
43.5
LED
.31
8
Dual Dimensions inches
mm
1.97
50
1.65
42
LED
2.02
51.5
2.36
60
LED
LED
1.65
42
2.36
60
2.75
70
2.02
51.5
LED
2.95
75
2.16
55
LED
2.04
52
.31
8
1.71
43.5
LED
1.65
42
LED
1.97
50
4.17
106
LED
2.03
51.5
1.97
50
1.65
42
LED
thread
M18x1
XS1M18k
XS1M18DA210
XS1M18DA210D
XS1M18DA210LD
XS1M18DA210LA
XS1M18k370D
XS1M18k370A
XS2M18k370
XS2M18k370D
XS2M18kB
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, DC; Universal Standard Length
243
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, DC; Univers al Standard Leng th
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded 0 to 4 mm
Non-shielded 0 to 6.4 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68 – cutting oil proof; IP67 for B screw terminal
Enclosure material Nickel plated brass Case: Nickel plated brass
Sensing face: PBT
Tightening torque (max.) Nickel plated brass 35 N•m 26 (26 lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11ms
Standard target size (steel) Shielded 0.7" x 0.7" (18 mm x 18 mm)
Non-shielded 0.94" x 0.94" (24 mm x 24 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 2 wire 20 AWG (0.5 mm2), PvR
3 wire 22 AWG (0.34 mm2), PvR
Electrical Std. KP-Models
Voltage range – nominal 12 - 48 Vdc 12 - 24 Vdc
Voltage limit (including ripple) 10 - 58 Vdc 10 - 38 Vdc
Voltage drop (across
switch), closed state
3 wire 2 V 2.6 V
2 wire 4 V
Minimum load current 2 wire 1.5 mA
Maximum load current 2 wire 100 mA
3 wire 200 mA
Current consumption (no load) 3 wire 10 mA
Residual (leakage) current, open state 2 wire 0.5 mA
On delay (max.) 2 wire 0.2 ms
3 wire 0.15 ms
Off delay (max.) 2 wire 0.2 ms
3 wire 0.35 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity
(RFI) IEC 61000-4-3 Level 3
Electrostatic; transients;
impulse 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3
(L - indicates level number) 3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE218
Metal mounting nuts and lock washers XSZE118
Mounting bracket, 90° steel 9006PA 18
Mounting bracket, plastic XSZB118
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 7428
Stainless 74282
For additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA101Y Micro Conn., 3 pin, 2 m, straight
XSZCA111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk
9006PAkk
74281
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
13
2
BK/4
WH/2
BK/4
WH/2
BN/1 (NO),BU/3 (NC)
BU/3 (NO),BU/1 (NC)
+
-
PNP
BU/3 (NO),BU/1 (NC)
+
-
NPN
BN/1 (NO),BU/3 (NC)
4 wire, programmable, NO or NC output
2 wire non-polarized
BN/3 +/-
-/+
BU/4
®
Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, DC; Universal Standard Length, Non-corrosive
©1997- 2002 Schneider Electric All Rights Reserved
244 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, DC; Univers al Standard Leng th, Non-corrosive
Features
Faster troubleshooting aided by high visibility 360° indicators
2 wire versions simplify wiring
High impact stainless steel and plastic cases for aggressive environments - cutting oils,
grease, solvents, etc.
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68)
Pigtail connector version (0.8 m /2.6' cable) provides cutting oil (IP68) ratings and
connection for aggressive environments.
Significant replacement time savings using patented plastic mounting bracket (no gauging)
or connectors
Trouble free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Stainless steel locknuts for metal or plastic mounting nuts for plastic housings included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
a To order a normally closed (N.C.) version change the A to B, example: XS1M12PA371 to XS1M12PB371.
See next page under specifications for LED function.
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Max.
Load
Operating
Frequency
Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
Stainless steel case
Shielded, 2 m (6.6’) cable
5 mm 2-wire 12-48 V N.O.a1.5-100 mA 3000 Hz A XS1M18DA211
5 mm PNP 12-48 V N.O. 200 mA 2000 Hz A XS1M18PA371
5 mm NPN 12-48 V N.O. 200 mA 2000 Hz A XS1M18NA371
Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail
5 mm 2-wire 12-48 V N.O.a1.5-100 mA 3000 Hz A 21,22 XS 1M1 8DA211L A
Non-shielded, 2 m (6.6’) cable
8 mm PNP 12-48 V N.O. 200 mA 2000 Hz A XS2M18PA371
8 mm NPN 12-48 V N.O. 200 mA 2000 Hz A XS2M18NA371
Plastic case
Non-shielded, 2 m (6.6’) cable
8 mm PNP 12-48 V N.O.a200 mA 2000 Hz A XS4P18PA370
8 mm NPN 12-48 V N.O.a200 mA 2000 Hz A XS4P18NA370
8 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 2000 Hz A XS4P18KP340
Non-shielded, connector - micro style
8 mm PNP 12-48 V N.O.a200 mA 2000 Hz A 11,12,13,15,16 XS4P18PA370D
8 mm NPN 12-48 V N.O.a200 mA 2000 Hz A 11,12,14,15,16 XS4P18NA370D
8 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 2000 Hz A 11,12,15,16 XS4P18KP340D
Non-shielded, screw terminal connector
8 mm PNP 12-48 V N.O. 200 mA 2000 Hz A XS4P18PA370B
8 mm NPN 12-48 V N.O. 200 mA 2000 Hz A XS4P18NA370B
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0
XS2/XS4 Non-shielded e: 16/.63 e: 96/3.78 e: 24/.94 D: 54/2.13, H: 8/.31
.31
8
2.04
52
1.71
43.5
LED
1.97
50
1.65
42
LED
2.02
51.5
2.36
60
LED
1.97
50
1.65
42
LED
2.36
60
2.02
51.5
LED
2.75
70
2.02
51.5
LED
thread
M18x1
Dual Dimensions inches
mm
XS1M18DA211
XS1M18k371
XS1M18DA211LA
XS2M18k371
XS4P18k370
XS4P18k370D
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, DC; Universal Standard Length, Non-corrosive
245
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, DC; Univers al Standard Leng th, Non-corrosive
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded 0 to 4 mm
Non-shielded 0 to 6.4 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68
Enclosure material Stainless steel Case #303 Stainless steel
Sensing face PBT
Plastic PBT
Tightening torque (max.) Stainless steel 50 N•m 37 (lb-ft)
Plastic 5 N•m 3.7 (lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded 0.7" x 0.7" (18 mm x 18 mm)
Non-shielded 0.94" x 0.94" (24 mm x 24 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
Cable 2 wire 20 AWG (0.5 mm2), PvR
3 wire 22 AWG (0.34 mm2), PvR
Electrical Standard KP-
Models
Voltage range 12 to 48 Vdc 12 to 24 Vdc
Voltage limit (including ripple) 10 to 58 Vdc 10 to 38 Vdc
Voltage drop (across
switch), closed state
Nickel plated brass
& Stainless
2 wire 4 V -
3 wire 2 V -
4 wire - 2.6
Plastic 3 wire 2 V
Minimum load current 2 wire 1.5 mA
Maximum load current 2 wire 100 mA
3 wire 200 mA
Residual (leakage) current, open state 2 wire 0.6 mA
On delay (max.) 0.15 ms
Off delay (max.) 0.35 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse
(L - indicates level number)
2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3;
60947.5.2 L3
3 wire: IEC 6000-4-2 L2; IEC 61000-4-4 L3;
60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE218
Stainless steel mounting nuts XSZE318
Locknut washers, stainless steel XSZE918
Mounting bracket, 90° steel 9006PA18
Mounting bracket, plastic XSZB118
0.5" NPT conduit adapter length 2" (50.8mm) Aluminum 7428
Stainless 74282
For additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA101Y Micro Conn., 3 pin, 2 m, straight
XSZCA111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk
9006PAkk
7428k
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
13
2
BK/4
WH/2
BK/4
WH/2
BN/1 (NO),BU/3 (NC)
BU/3 (NO),BU/1 (NC)
+
-
PNP
BU/3 (NO),BU/1 (NC)
+
-
NPN
BN/1 (NO),BU/3 (NC)
4 wire, programmable, NO or NC output
2 wire non-polarized
BN/3 +/-
-/+
BU/4
®
Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, AC/DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
246 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, AC/DC; Uni versal Standard Leng th
Features
360° LED indicators
Extended temperature range
Extended supply voltage range
IP68 AC/DC power supply
Patented plastic mounting bracket
Connector options
Extensive protective circuitry
Metal locknuts for metal or plastic mounting nuts for plastic housings included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M12PA260 to XS1M12PB260.
See next page under specifications for LED function.
Nominal
Sensing
Distance
AC or
AC/DC
Output
Mode
Voltage Range Operating
Frequencies SCP Indicator
LED
Mating
Connector
Style (see p. 518)
Catalog
Number
AC DC AC DC
Nickel brass case
Shielded, 2 m (6.6’) cable
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no A XS1M18MA230
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz yes C XS1M18MA250
Shielded, connector - micro style AC
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no B 17,18 XS1M18MA230K
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz yes B 17,18 XS1M18MA250K
Shielded, connector - mini style
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no B 23,24 XS1M18MA230A
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz yes C 23,24 XS1M18MA250A
Shielded, screw terminal connection
5 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 3000 Hz no B XS1M18MA230B
Non-shielded, 2 m (6.6’) cable
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no A XS2M18MA230
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz yes C XS2M18MA250
Non-shielded, connector - micro style AC
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no B 23,24 XS2M18MA230K
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz yes B 23,24 XS2M18MA250K
Non-shielded, connector - mini style
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no B 18 XS2M18MA230A
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz yes C 18 XS2M18MA250A
Plastic case
Non-shielded, 2 m (6.6’) cable
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no A XS4P18MA230
Non-shielded, connector - micro style
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no A 17,18 XS4P18MA230K
Non-shielded, connector - mini style
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no A 23,24 XS4P18MA230A
Shielded, screw terminal connection
8 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no B XS4P18MA230B
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0
XS2/XS4 Non-shielded e: 16/.63 e: 96/3.78 e: 24/.94 D: 54/2.13, H: 8/.31
2.36
60
2.02
51.5
LED
2.75
70
2.02
51.5
LED
2.95
75
2.16
55
LED
2.04
52
.31
8
1.71
43.5
LED
2.44
62
.31
8
1.71
43.5
LED
2.63
67
.31
8
1.85
47
LED
2.36
60
2.02
51.5
LED
2.75
70
2.02
51.5
LED
2.89
73.5
2.04
52
LED
thread
M18x1
Dual Dimensions inches
mm
XS1M18 XS1M18kK
XS1M18kA
XS2M18k
XS2M18kK
XS2M18kA
XS4P18k230
XS4P18k230A
XS4P18k230K
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
OSICONCEPT Proximity Sensors
XS Tubular Inductive Sensors
18 mm Diameter, AC/DC; Universal Standard Length
247
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 18 mm Diameter, AC/DC; Uni versal Standard Leng th
Specifications
aRefer to p. 351 for target material correction coefficient Km.
qFor devices without SCP, see p. 298 for protective fuses.
Mechanical
Usable sensing rangeaShielded 0 to 4 mm
Non-shielded 0 to 6.4 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 4X, 6P, 12, 13
IEC Type IP68
Enclosure material Nickel plated brass Case Nickel plated brass
Sensing face PBT
Plastic PBT
Tightening torque (max.) Nickel plated brass 35 N•m 26 (lb-ft)
Plastic 5 N•m 3.7 (lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded 0.7" x 0.7" (18 mm x 18 mm)
Non-shielded 0.94" x 0.94" (24 mm x 24 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
C2 LED indicators: Red shows output status
Green shows normal operation (SCP only)
Cable 2 wire 20 AWG (0.5 mm2), PvR
3 wire 22 AWG (0.34 mm2), PvR
Electrical
Voltage range 24 to 240 Vac, 24-210 Vdc
Voltage limit (including ripple) 20 to 264 Vac/dc
Voltage drop (across
switch), closed state (max) 5.5 V
Inrush current 2 A
Minimum load current 5 mA
Maximum load current
200 mA
20 Vdc 58 IEC 60947-5-2 Utilization category DC-13
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Residual (leakage) current,
open state
without SCP 0.6 mA
with SCP 1.5 mA
On delay (max) without SCP 0.2 ms
with SCP 2 ms
Off delay (max) without SCP 0.2 ms
with SCP 4 ms
Power-up delay (max.) without SCP 40 ms
with SCP 70 ms
Protective circuitry
Short circuit protection Optionalq
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 5 meter cable L1
10 meter cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE218
Metal mounting nuts and lock washers XSZE118
Mounting bracket, 90° steel 9006PA18
Mounting bracket, plastic XSZB118
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 7428
Stainless 74282
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(U20 or K suffix; U78 or A suffix)
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZCA101Y Micro Conn., 3 pin, 2 m, straight
XSZCA111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk
9006PAkk
7428k
Wiring
Connector
Micro Mini Cable
Blue BU –
Brown BN +
Black BK Output
1
3
2
13
2
Wire color/connector pin
2 wire, AC/DC or AC
BN/2 L1 +/-
L2 -/+
BU/3
AC/DC
®
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, DC; Economy Short Length
©1997- 2002 Schneider Electric All Rights Reserved
248 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, DC; Econ omy Short Length
Features
aTo order a normally closed (N.C.) version change the A to B, example: XS1N12PA340 to XS1N12PB340.
See next page under specifications for LED function.
See dimension X below.
360° LED indicators
Extended range models
Complementary N.O. + N.C. models
Rugged metal or plastic cases
Patented plastic mounting bracket
Connector options
Extensive protective circuitry
Works with unregulated DC supply powered by
24 V secondary transformer
Metal locknuts for metal or plastic mounting
nuts for plastic housing included
Normally closed (N.C.) output available on
versions mode marked a
UL Listed, CSA Certified and CE Mark
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Operating
Frequency
Indicator
LED
Mating Connector
Style (see p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
10 mm PNP 12-24 V N.O.a1000 Hz A XS1N30PA340
10 mm NPN 12-24 V N.O.a1000 Hz A XS1N30NA340
10 mm PNP 12-24 V N.O. + N.C. 1000 Hz A XS1N30PC410
10 mm NPN 12-24 V N.O. + N.C. 1000 Hz A XS1N30NC410
Shielded, connector - micro style
10 mm PNP 12-24 V N.O.a1000 Hz B 11,12,13,15,16 XS1N30PA340D
10 mm NPN 12-24 V N.O.a1000 Hz B 11,12,14,15,16 XS1N30NA340D
10 mm PNP 12-24 V N.O. + N.C. 1000 Hz B 11,12,13,15,16 XS1N30PC410D
10 mm NPN 12-24 V N.O. + N.C. 1000 Hz B 11,12,14,15,16 XS1N30NC410D
Shielded, EXTENDED RANGE, 2 m (6.6’) cable
20 mm PNP 12-24 V N.O.a500 Hz A XS1N30PA349
20 mm NPN 12-24 V N.O.a500 Hz A XS1N30NA349
Shielded, EXTENDED RANGE, connector - micro style
20 mm PNP 12-24 V N.O.a500 Hz B 11,12,13,15,16 XS1N30PA349D
20 mm NPN 12-24 V N.O.a500 Hz B 11,12,14,15,16 XS1N30NA349D
Non-shielded, 2 m (6.6’) cable
15 mm PNP 12-24 V N.O. 1000 Hz A XS2N30PA340
15 mm NPN 12-24 V N.O. 1000 Hz A XS2N30NA340
15 mm PNP 12-24 V N.O. + N.C. 1000 Hz A XS2N30PC410
15 mm NPN 12-24 V N.O. + N.C. 1000 Hz A XS2N30NC410
Non-shielded, connector - micro style
15 mm PNP 12-24 V N.O. 1000 Hz B 11,12,13,15,16 XS2N30PA340D
15 mm NPN 12-24 V N.O. 1000 Hz B 11,12,14,15,16 XS2N30NA340D
15 mm PNP 12-24 V N.O. + N.C. 1000 Hz B 11,12,13,15,16 XS2N30PC410D
15 mm NPN 12-24 V N.O. + N.C. 1000 Hz B 11,12,14,15,16 XS2N30NC410D
Plastic case
Non-shielded, 2 m (6.6’) cable
15 mm PNP 12-24 V N.O. 1000 Hz A XS4P30PA340
15 mm NPN 12-24 V N.O. 1000 Hz A XS4P30NA340
15 mm PNP 12-24 V N.O. + N.C. 1000 Hz A XS4P30PC410
15 mm NPN 12-24 V N.O. + N.C. 1000 Hz A XS4P30NC410
Non-shielded, connector - micro style
15 mm PNP 12-24 V N.O. 1000 Hz A 11,12,13,15,16 XS4P30PA340D
15 mm NPN 12-24 V N.O. 1000 Hz A 11,12,14,15,16 XS4P30NA340D
15 mm PNP 12-24 V N.O. + N.C. 1000 Hz A 11,12,13,15,16 XS4P30PC410D
15 mm NPN 12-24 V N.O. + N.C. 1000 Hz A 11,12,14,15,16 XS4P30NC410D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 20/.79 e: 120/4.72 e: 30/1.18 D: 30/1.18, H: 0/0 x: 0/0
XS1 Extended range e: 40/1.57 e: 240/9.45 e: 60/2.36 x: 6/.24
XS2/XS4 Non-shielded e: 60/2.36 e: 180/7.09 e: 45/1.77 D: 90/3.54, H: 30/1.18
XS1N30k
1.59
40.5
1.26
32
LED
1.59
40.5
1.26
32
LED
1.97
50
1.18
30
LED
.51
13
27.5
.74
19
LED
.51
13
1.45
37
.74
19
LED
1.59
40.5
1.30
33
LED
1.97
50
1.33
34
LED
thread
M30x1.5
Dual Dimensions inches
mm
1.97
50
1.18
30
LED
XS1N30kD
XS1N30k349
XS1N30k349D
XS2N340k
XS2N30kD
XS4P30 XS4P30kD
thread
M30x1.5
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
Mounting in a metal
support x
D
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, DC; Economy Short Length
249
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, DC; Econ omy Short Length
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded Standard Range 0 to 8 mm
Extended Range 0 to 16 mm
Non-shielded 0 to 12 mm
Standard temperature range Nickel plated brass -25° C to +70° C (-13° F to +158° F)
Plastic -25° C to +80° C (-13° F to +176° F)
Extended range -25° C to 50° C (-13° F to +122° F)
Enclosure rating - cable
(for connector, see p. 518)
Nickel plated brass NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP67
Plastic NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68
Enclosure material
Nickel plated brass Case Nickel plated brass
Sensing face PBT
Plastic Case PBT
Sensing face PBT
Tightening torque (max.) Nickel plated brass 40 N•m 29.5 (lb-ft)
Plastic 20 N•m 15 (lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded Standard Range 1.18" x 1.18" (30 mm x 30 mm)
Extended range 1.88" x 1.88" (48 mm x 48 mm)
Unshielded 1.41" x 1.41" (36 mm x 36 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
BOne LED visible from 4 quadrants: Shows output
status
Cable 3 or 4 wire 22 AWG (0.34 mm2), PvR
Electrical
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch), closed state 2 V
Maximum load current 200 mA
Current consumption (no load) 10 mA
On delay (max.) Shielded Standard Range 0.3 ms
Extended Range 0.6 ms
Non-shielded 0.3 ms
Off delay (max.) Shielded Standard Range 0.7 ms
Extended Range 1.4 ms
Non-shielded 0.7 ms
Power up delay 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse
(L – indicates level number)
2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L2;
60947.5.2 L3
3 wire: IEC 61000-4-2 L3; IEC 61000-4-4L3;
60947.5.2 L3
Extended range: IEC 61000-4-4 L3
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
(cable type and standard sensing distance only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE230
Metal mounting nuts and lock nuts XSZE130
Mounting bracket 90° steel 9006PA30
Mounting bracket, plastic, long length XSZB130
0.5" NPT conduit adapter length 2" (50.8mm) Aluminum 7427
For additional cable options and lengths see p. 518
A
ccessories. . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
9006PAkk
7427
W
iring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
NC WH/2
BK/4
BN/1
BU/3
+
-
PNP NO
4 wire NO + NC
NC WH/2
BK/4
BN/1
BU/3
+
-
NPN NO
®
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
250 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, DC; Univers al Standard Leng th
Features
Faster troubleshooting aided by high visibility 360° indicators
2 wire versions simplify wiring
Rugged case designed for aggressive industrial environments
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./
N.C. output circuit
Pigtail connector version (0.8 m /2.6' cable) provides cutting oil (IP68) ratings and
connection for aggressive environments.
Significant replacement time savings using patented plastic mounting bracket
(no gauging) or connectors
Trouble free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Metal mounting lock nuts included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M12PA370 to XS1M12PB370.
See next page under specifications for LED function.
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Max.
Load
Operating
Frequency
Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
10 mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz A XS1M30DA210
10 mm PNP 12-48 V N.O.a200 mA 1000 Hz A XS1M30PA370
10 mm NPN 12-48 V N.O.a200 mA 1000 Hz A XS1M30NA370
10 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 1000 Hz A XS1M30KP340
Shielded, connector - micro style DC - 0.8 m (2.6 ft) pigtail
10 mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz A 11,12,15,16 XS1M30DA210LD
Shielded, connector - micro style DC
10 mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz B 11,12,15,16 XS1M30DA210D
10 mm PNP 12-48 V N.O.a200 mA 1000 Hz B 11,12,13,15,16 XS1M30PA370D
10 mm NPN 12-48 V N.O.a200 mA 1000 Hz B 11,12,14,15,16 XS1M30NA370D
10 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 1000 Hz B 11,12,15,16 XS1M30KP340D
Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail
10 mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz A 21,22 XS1M30DA210LA
Shielded, connector - mini style
10 mm PNP 12-48 V N.O. 200 mA 1000 Hz B 21,22 XS1M30PA370A
10 mm NPN 12-48 V N.O. 200 mA 1000 Hz B 21,22 XS1M30NA370A
Shielded, connector - screw terminal connection
10 mm 2 wire 12-48 V N.O.a1.5-100 mA 2000 Hz B XS1M30DA210B
10 mm PNP 12-48 V N.O.a200 mA 1000 Hz B XS1M30PA370B
10 mm NPN 12-48 V N.O.a200 mA 1000 Hz B XS1M30NA370B
Non-shielded, 2 m (6.6’) cable
15 mm PNP 12-48 V N.O.a200 mA 1000 Hz A XS2M30PA370
15 mm NPN 12-48 V N.O.a200 mA 1000 Hz A XS2M30NA370
15 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 1000 Hz A XS2M30KP340
Non-shielded, connector - micro style
15 mm PNP 12-48 V N.O.a200 mA 1000 Hz B 11,12,13,15,16 XS2M30PA370D
15 mm NPN 12-48 V N.O.a200 mA 1000 Hz B 11,12,14,15,16 XS2M30NA370D
15 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 1000 Hz B 11,12,15,16 XS2M30KP340D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 20/.79 e: 120/4.72 e: 30/1.18 D: 30/1.18, H: 0/0
XS2 Non-shielded e: 60/2.36 e: 180/7.09 e: 45/1.77 D: 90/3.54, H: 30/1.18
LED
50
1.97
42
1.65
LED
60
2.36
40
1.57
LED
70
2.75
51.5
2.02
LED
47
1.85
38.5
13
.51
1.51
LED
74
2.95
54
2.12
LED
57
2.24
38.5
1.51
13
.51
LED
50
1.97 42
1.65
LED
50
1.97 42
1.65
thread
M30x1.5
Dual Dimensions inches
mm
LED
60
2.36
51.5
2.02
XS1M30DA210
XS1M30k370
XS1M30DA210D
XS1M30k370D
XS2M30k370 XS1M30k370A
XS2M30k370D
XS1M30DA210LD
XS1M30DA210LA
thread
M30x1.5
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, DC; Universal Standard Length
251
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, DC; Univers al Standard Leng th
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded 0 to 8 mm
Non-shielded 0 to 12 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(for connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68 – cutting oil proof, IP67 for B screw terminals
Enclosure material Nickel plated brass Case: Nickel plated Brass
Sensing face: PBT
Tightening torque (max.) Nickel plated brass 50 N•m 37 (lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded 1.18" x 1.18" (30 mm x 30 mm)
Non-shielded 1.41" x 1.41" (36 mm x 36 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
Cable 2 wire 20 AWG (0.5 mm2), PvR
3 wire 22 AWG (0.34 mm2), PvR
Electrical Std. KP-Models
Voltage range – nominal 12-48 Vdc 12-24 Vdc
Voltage limit (including ripple) 10-58 Vdc 10-38 Vdc
Voltage drop (across
switch), closed state
3 wire 2 V 2.6 V
2 wire 4 V
Minimum load current 2 wire 1.5 mA
Maximum load current 2 wire 100 mA
3 wire 200 mA
Current consumption
(no load) 3 wire 10 mA
Residual (leakage) current,
open state 2 wire 0.5 mA
On delay (max.) 2 wire 0.2 ms
3 wire 0.3 ms
Off delay (max.) 2 wire 0.3 ms
3 wire 0.7 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse
(L - indicates level number)
2 wire IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3
3 wire IEC 61000-4-2 L3; IEC 61000-4-4 L2; 60947.5.2 L3
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40°+ C (-40°+ F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Metal mounting lock nuts XSZE130
Mounting bracket, 90° steel and lock washers 9006PA30
Mounting bracket, plastic XSZB130
0.5" NPT conduit adapter length 2" (50.8mm) Aluminum 7427
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA101Y Micro Conn., 3 pin, 2 m, straight
XSZCA111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk
9006PAkk
7427
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
31
2
BK/4
WH/2
BK/4
WH/2
BN/1 (NO),BU/3 (NC)
BU/3 (NO),BU/1 (NC)
+
-
PNP
BU/3 (NO),BU/1 (NC)
+
-
NPN
BN/1 (NO),BU/3 (NC)
4 wire, programmable, NO or NC output
2 wire non-polarized
BN/3 +/-
-/+
BU/4
®
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, DC; Universal Standard Length, Non-Corrosive
©1997- 2002 Schneider Electric All Rights Reserved
252 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, DC; Univers al Standard Leng th, Non-corrosive
Features
Faster troubleshooting aided by high visibility 360° indicators
2 wire versions simplify wiring
High impact stainless steel and plastic cases for aggressive environments - cutting oils,
grease, solvents, etc.
Worry free replacement: standard length, extended temperature and supply voltage range,
improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./
N.C. output circuit
Significant replacement time savings using patented plastic mounting bracket (no gauging)
or connectors
Pigtail connector version (0.8 m /2.6' cable) provides cutting oil (IP68) ratings and
connection for aggressive environments.
Trouble free operation ensured by extensive protective circuitry
Works with unfiltered rectified power supply
Stainless steel or plastic mounting nuts included
Normally closed (N.C.) output available on versions markeda
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M12PA371 to XS1M12PB371.
See next page under specifications for LED function.
Nominal
Sensing
Distance
Circuit
Type
Voltage
Range
Output
Mode
Max
Load
Operating
Frequency
Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
Stainless steel case
Shielded, 2 m (6.6’) cable
10 mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz A XS1M30DA211
10 mm PNP 12-48 V N.O. 200 mA 1000 Hz A XS1M30PA371
10 mm NPN 12-48 V N.O. 200 mA 1000 Hz A XS1M30NA371
Shielded, connector - micro style - 0.8 m (2.6 ft) pigtail
10 mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz A 11,12,15,16 XS1M30DA211LD
Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail
10mm 2-wire 12-48 V N.O.a1.5-100 mA 2000 Hz A 21,22 XS1M30DA211LA
Non-shielded, 2 m (6.6’) cable
15 mm PNP 12-48 V N.O. 200 mA 1000 Hz A XS2M30PA371
15 mm NPN 12-48 V N.O. 200 mA 1000 Hz A XS2M30NA371
Plastic case
Non-shielded, 2 m (6.6’) cable
15 mm PNP 12-48 V N.O.a200 mA 1000 Hz A XS4P30PA370
15 mm NPN 12-48 V N.O.a200 mA 1000 Hz A XS4P30NA370
15 mm PNP/NPN 12-24 V N.O./N.C. 200 mA 1000 Hz A XS4P30KP340
Non-shielded, connector - micro style DC
15 mm PNP 12-48 V N.O.a200 mA 1000 Hz A 11,12,13,15,16 XS4P30PA370D
15 mm NPN 12-48 V N.O.a200 mA 1000 Hz A 11,12,14,15,16 XS4P30NA370D
15 mm PNP/NPN 12-24 V N.O/.N.C. 200 mA 1000 Hz A 11,12,15,16 XS4P30KP340D
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 20/.79 e: 120/4.72 e: 30/1.18 D: 30/1.18, H: 0/0
XS2/XS4 Non-shielded e: 60/2.36 e: 180/7.09 e: 45/1.77 D: 90/3.54, H: 30/1.18
2.36
60
2.02
51.5
LED
1.85
47
1.51
38.5
.51
13
LED
1.97
50
1.65
42
LED
2.36
60
2.02
51.5
LED
2.75
70
2.02
51.5
LED
LED
1.97
50
42
1.65
thread
M30x1.5
Dual Dimensions inches
mm
XS1M30kDA2
XS1M30k371
XS1M30DA211LA
XS2M30k371
XS4P30k370
XS4P30k370D
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
LimitedProductAvailability
on
DCTwoWireProducts
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, DC; Universal Standard Length, Non-Corrosive
253
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, DC; Univers al Standard Leng th, Non-corrosive
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing rangeaShielded 0 to 8 mm
Non-shielded 0 to 12 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating cable
(for connector, see p. 517)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68
Enclosure material Stainless steel Case #303 Stainless steel
Sensing face PBT
Plastic PBT
Tightening torque (max.) Stainless steel 100 N•m 74 (lb-ft)
Plastic 20 N•m 15 (lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded 1.18" x 1.18" (30 mm x 30 mm)
Non-shielded 1.41" x 1.41" (36 mm x 364 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type A 360° ring LED: Shows output status
Cable 2 wire 20 AWG (0.5 mm2), PvR
3 wire 22 AWG (0.34 mm2), PvR
Electrical Standard KP-Models
Voltage range – nominal 12 to 48 Vdc 12-24 Vdc
Voltage limit (including ripple) 10 to 58 Vdc 10-38 Vdc
Voltage drop (across
switch), closed state
2 wire 4 V
3 wire 2 V
4 wire 2.6 V
Minimum load current 2 wire 1.5 mA
Maximum load current 2 wire 100 mA
3 wire 200 mA
Current consumption (on load) 3 wire 10 mA
Residual (leakage) current, open state 2 wire 0.5 mA
On delay (max.) 2 wire 0.2 ms
3 wire 0.3 ms
Off delay (max.) 2 wire 0.3 ms
3 wire 0.7 ms
Power-up delay (max.) 5 ms
Protective circuitry
Short circuit protection Yes
Overload Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse
(L - indicates level number)
2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3;
60947.5.2 L3
3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3;
60947.5.2 L4
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range cable type only Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE230
Stainless steel mounting nuts XSZE330
Locknut washers, stainless steel XSZE930
Mounting bracket, 90° steel 9006PA30
Mounting bracket, plastic XSZB130
0.5" NPT conduit adapter length 2" (50.8mm) Aluminum 7427
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA101Y Micro Conn., 3 pin, 2 m, straight
XSZCA111Y Micro Conn., 3 pin, 2 m, 90°
XSZB1kk
9006PAkk
7427
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BK/4 NO
BK/2 NC BK/2 NC
BK/4 NO
Wire color/connector pin
3 wire NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
13
2
BK/4
WH/2
BK/4
WH/2
BN/1 (NO),BU/3 (NC)
BU/3 (NO),BU/1 (NC)
+
-
PNP
BU/3 (NO),BU/1 (NC)
+
-
NPN
BN/1 (NO),BU/3 (NC)
4 wire, programmable, NO or NC output
2 wire non-polarized
BN/3 +/-
-/+
BU/4
®
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, AC/DC; Universal Standard Length
©1997- 2002 Schneider Electric All Rights Reserved
254 10/02
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, AC/DC; Uni versal Standard Leng th
Features
360° LED indicators
Extended temperature range
Extended supply voltage range
•IP68
AC/DC power supply
Patented plastic mounting bracket
Connector options
Extensive protective circuitry
Metal lock nuts for metal or plastic mounting nuts for plastic housing and lock washers
included
Normally closed (N.C.) output available on versions marked a
UL Listed, CSA Certified and CE Mark
aTo order a normally closed (N.C.) version change the A to B, example: XS1M30PA260 to XS1M12PB260.
See next page under specifications for LED function.
Nominal
Sensing
Distance
AC or
AC/DC
Output
Modea
Volt age Range Operating
Frequency SCP Indicator
LED
Mating
Connector Style
(see p. 518)
Catalog
Number
AC DC AC DC
Nickel plated brass case
Shielded, 2 m (6.6’) cable
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no A XS1M30MA230
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz yes C XS1M30MA250
Shielded, connector - micro style AC
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no B 13,14 XS1M30MA230K
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz yes B 13,14 XS1M30MA250K
Shielded, connector - mini style
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no B 17,20 XS1M30MA230A
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz yes C 18,20 XS1M30MA250A
Shielded, screw terminal connection
10 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 2000 Hz no B XS1M30MA230B
Non-shielded, 2 m (6.6’) cable
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no A XS2M30MA230
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz yes C XS2M30MA250
Non-shielded, connector - micro style AC
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no B 13,14 XS2M30MA230K
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz yes B 13,14 XS2M30MA250K
Non-shielded, connector - mini style
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no B 18,19 XS2M30MA230A
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz yes C 18,19 XS2M30MA250A
Plastic case
Non-shielded, 2 m (6.6’) cable
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no A XS4P30MA230
Non-shielded, connector - micro style
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no A 13,14 XS4P30MA230K
Non-shielded, connector - mini style
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no A 18,20 XS4P30MA230A
Non-shielded, screw terminal connector
15 mm AC/DC N.O.a24-240 V 24-210 V 25 Hz 1000 Hz no B XS4P30MA230B
Minimum Mounting Clearances (mm/inches)
XS1 Shielded e: 20/.79 e: 120/4.72 e: 30/1.18 D: 30/1.18, H: 0/0
XS2/XS4 Non-shielded e: 60/2.36 e: 180/7.09 e: 45/1.77 D: 90/3.54, H: 30/1.18
Dual Dimensions inches
mm
2.36
60
2.02
51.5
LED
2.75
70
2.02
51.5
LED
2.95
75
2.12
54
LED
1.85
47
.51
13
1.51
38.5
LED
2.24
57
.51
13
1.51
38.5
LED
2.44
62
.51
13
1.61
41
LED
LED
2.36
60
2.02
51.5
2.75
70
2.02
51.5
LED
2.95
75
2.12
54
LED
XS4P30k230A
XS2P30kXS4P30k230K
XS2M30kA
XS1M30kK
XS2M30k
XS1M30kA
XS1M30kK
XS1M30k
thread
M30x1.5
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
Proximity Sensors
XS Tubular Inductive Sensors
30 mm Diameter, AC/DC; Universal Standard Length
255
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Se nsors / 30 mm Diameter, AC/DC; Uni versal Standard Leng th
Specifications
aRefer to p. 351 for target material correction coefficient Km.
qFor devices without SCP, see p. 298 for protective fuses.
Mechanical
Usable sensing rangeaShielded 0 to 8 mm
Non-shielded 0 to 12 mm
Standard temperature range -25° C to +80° C (-13° F to +176° F)
Enclosure rating - cable
(connector, see p. 518)
NEMA Type 3, 4X, 6P, 12, 13
IEC Type IP68 – P67 for B screw terminals
Enclosure material Nickel plated brass Case Nickel plated brass
Sensing face PBT
Plastic PBT
Tightening torque (max.) Nickel plated brass 50 N•m 37 (lb-ft)
Plastic 20 N•m 15 (lb-ft)
Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz
Shock resistance (IEC 60068.2.27) 50 G duration 11 ms
Standard target size (steel) Shielded 1.18" x 1.18" (30 mm x 30 mm)
Non-shielded 1.41" x 1.41" (36 mm x 36 mm)
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type
A 360° ring LED: Shows output status
B One LED visible from 4 quadrants: Shows output status
C2 LED indicators: Red shows output status
Green shows normal operation (SCP only)
Cable 2 wire 22 AWG (0.5 mm2), PvR
Electrical
Voltage range – nominal 24 to 240 Vac (50/60 Hz), 24 to 210 Vdc
Voltage limit (including ripple) 20 to 264 Vac/Vdc
Voltage drop (across switch), closed state 5.5 V
Inrush current 2 A
Minimum load current 5 mA
Maximum load current
AC 300 mA
DC
200 mA
20 Vdc 58 IEC 60947-5-2 Utilization category DC-13
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Residual (leakage) current,
open state
Without SCP 0.6 mA
With SCP 1.5 mA
On delay (max.) Without SCP 0.2 ms
With SCP 2 ms
Off delay (max.)
Without SCP 0.3 ms
With SCP 5 ms
Without SCP 40 ms
With SCP 70ms
Power-up delay (max.) Without SCP 40 ms
With SCP 70 ms
Protective circuitry
Short circuit protection Optionalq
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; transients; impulse IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range cable type only Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Plastic mounting nuts XSZE230
Metal mounting nuts and lock washers XSZE130
Mounting bracket, 90° steel 9006PA30
Mounting bracket, plastic XSZB130
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 7427
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(U20 or K suffix; U78 or A suffix)
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZCA101Y Mini Conn., 3 pin, 2 m, straight
XSZCA111Y Mini Conn., 3 pin, 2 m, 90°
XSZB1kk
9006PAkk
7427
Wiring
Connector
Micro Mini Cable
Blue BU –
Brown BN +
Black BK Output
1
3
2
31
2
Wire color/connector pin
2 wire, AC/DC or AC
BN/2 L1 +/-
L2 -/+
BU/3
AC/DC
®
Proximity Sensors
XS Tubular Inductive Sensors
Economy D Series – DC, AC
©1997- 2002 Schneider Electric All Rights Reserved
256 10/02
Proximity Sensors
XS Tubular Inductive Sensors / Economy D Series - DC, AC
Features
Entire family of proximity sensors dedicated to OEMs and “just enough” applications.
DC tubular body style ranging from 6.5 mm to 30 mm diameter, in 3 wire, N.O. output
AC tubular body style ranging from 12 mm to 30 mm diameter, in 2 wire, N.O. output
Brass metal case with either 2 meter cable or connector options
Shielded and non-shielded versions available
Mounting nuts included
Sold in multiples of 10 easy to open bags
aSee p. 517 for matching connector cables.
Circuit
Type
Output
Mode
Voltage
Range
Voltage Drop
Maximum
Load Current
Maximum
Operating
Frequency
Maximum
Catalog
Number
6.5 mm, Shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–1.5 mm
PNP N.O. 12 to 24 Vdc 3 V 50 mA 3000 Hz XS1L06PA140
NPN N.O. 12 to 24 Vdc 3 V 50 mA 3000 Hz XS1L06NA140
8 mm, Shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–1.5 mm
PNP N.O. 12 to 24 Vdc 3 V 50 mA 3000 Hz XS1D08PA140
NPN N.O. 12 to 24 Vdc 3 V 50 mA 3000 Hz XS1D08NA140
8 mm, Shielded, DC–Micro Style Connector a–Nominal Sensing Distance–1.5 mm
PNP N.O. 12 to 24 Vdc 3 V 50 mA 3000 Hz XS1D08PA140D
NPN N.O. 12 to 24 Vdc 3 V 50 mA 3000 Hz XS1D08NA140D
12 mm, Shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–2 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 2000 Hz XS1D12PA140
NPN N.O. 12 to 24 Vdc 3 V 100 mA 2000 Hz XS1D12NA140
12 mm, Shielded, DC–Micro Style Connector a–Nominal Sensing Distance–2 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 2000 Hz XS1D12PA140D
NPN N.O. 12 to 24 Vdc 3 V 100 mA 2000 Hz XS1D12NA140D
12 mm, Non-shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–4 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS2D12PA140
NPN N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS2D12NA140
12 mm, Non-shielded, DC–Micro Style Connector–Nominal Sensing Distance–4 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS2D12PA140D
NPN N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS2D12NA140D
12 mm, Shielded, AC–2 Meter (6') Cable–Nominal Sensing Distance–2 mm
2 wire N.O. 24 to 240 Vac 7V 200 mA 25 Hz XS1M12FA264
18 mm, Shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–5 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS1D18PA140
NPN N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS1D18NA140
18 mm, Shielded, DC–Micro Style Connector a–Nominal Sensing Distance–5 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS1D18PA140D
NPN N.O. 12 to 24 Vdc 3 V 100 mA 1000 Hz XS1D18NA140D
18 mm, Non-shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–8 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 250 Hz XS2D18PA140
NPN N.O. 12 to 24 Vdc 3 V 100 mA 250 Hz XS2D18NA140
18 mm, Non-shielded, DC–Micro Style Connector a–Nominal Sensing Distance–8 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 250 Hz XS2D18PA140D
NPN N.O. 12 to 24 Vdc 3 V 100 mA 250 Hz XS2D18NA140D
18 mm, Shielded, AC–2 Meter (6') Cable–Nominal Sensing Distance–5 mm
2 wire N.O. 24 to 240 Vac 4.5 V 300 mA 25 Hz XS1M18FA264
30 mm, Shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–10 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 200 Hz XS1D30PA140
NPN N.O. 12 to 24 Vdc 3 V 100 mA 200 Hz XS1D30NA140
30 mm, Shielded, DC–Micro Style Connector a–Nominal Sensing Distance–10 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 200 Hz XS1D30PA140D
NPN N.O. 12 to 24 Vdc 3 V 100 mA 200 Hz XS1D30NA140D
30 mm, Non-shielded, DC–2 Meter (6') Cable–Nominal Sensing Distance–15 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 60 Hz XS2D30PA140
NPN N.O. 12 to 24 Vdc 3 V 100 mA 60 Hz XS2D30NA140
30 mm, Non-shielded, DC–Micro Style Connector a–Nominal Sensing Distance–15 mm
PNP N.O. 12 to 24 Vdc 3 V 100 mA 60 Hz XS2D30PA140D
NPN N.O. 12 to 24 Vdc 3 V 100 mA 60 Hz XS2D30NA140D
30 mm, Shielded, AC–2 Meter (6') Cable–Nominal Sensing Distance–10 mm
2 wire N.O. 24 to 240 Vac 4.5 V 300 mA 25 Hz XS1M30FA264
c
b
a
a = Overall Length (mm)
b = Threaded Section (mm)
c = for Non-shielded Sensors (mm)
Dimensions
abc
IN mm IN mm IN mm
6.5 mm Cable 1.65 42.0
Connector––––––
8 mm Cable 1.65 42.0 1.60 40.6
Connector 2.42 61.4 1.56 39.6
12 mm Cable 1.66 42.2 1.57 40.0 .26 7
Connector 2.09 53.0 1.56 39.6
18 mm Cable 2.06 52.2 1.95 49.6
Connector 2.52 64.0 1.96 49.7
30 mm Cable 2.05 52.0 1.95 49.6
Connector––––––
thread
M30x1.5
thread
M18x1
thread
M12x1
thread
M8x1
Proximity Sensors
XS Tubular Inductive Sensors
Economy D Series – DC, AC
257
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Sensors / Economy D Series - DC, AC
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Accessories
Mechanical DC AC
Diameter 0.25"
(6.5 mm)
0.31"
(8 mm)
0.47"
(12 mm)
0.7"
(18 mm)
1.18"
(30 mm)
0.47"
(12 mm)
0.7"
(18 mm)
1.18"
(30 mm)
Usable Sensing
Range a
Shielded 0.04"
(1.2mm)
0.04"
(1.2 mm)
0.06"
(1.6 mm)
0.16"
(4 mm)
0.31"
(8 mm)
0.06"
(1.6 mm)
0.16"
(4 mm)
0.31"
(8 mm)
Non-shielded 0.12"
(3.2 mm)
0.25"
(6.4 mm)
0.47"
(12 mm) –––
Temperature Range -13° F to +158° F (-25° C to +70° C)
Enclosure
Rating
NEMA Type 1
CENELEC Type IP66 (connector style is IP65) IP67
Vibration 25 G, amplitude =/- 2 mm, f = 10-55 Hz
Shock Resistance 50 G, for 11 ms
Maximum Differential (% of Sr) 15%
Maximum Repeatability (% of Sr) 3%
LED Indicator Type One, mounted at rear (connector style is 4 viewing ports at 90 degrees)
Enclosure Material Brass
Wiring 3 x 0.34 mm2 (8 mm = 3 x 0.11 mm2) 2 x 0.34 mm2
Electrical
Voltage Range 12 to 24 Vdc 24 to 240 Vac
Voltage Limit (Including Ripple) 10 to 30 Vdc 20 to 264 Vac
Current Consumption (Maximum) (No Load) 10 mA
Maximum Leakage (Residual) Current–open State 1.5 mA
Voltage Drop (Closed State) 3 V 7 V 4.5 V
Power-up Delay (Maximum) 5 ms 5 ms 5 ms 5 ms 10 ms 40 ms
On Delay (Maximum) 0.5 ms 0.5 ms 0.5 ms 1 ms 2 ms 10 ms
Off Delay (Maximum) 1 ms 1 ms 0.5 ms 2 ms 6 ms 15 ms
Protective
Circuitry
Short Circuit Protection Yes No
Overload Protection Yes No
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Description For Sensor Diameter Catalog Number
Mounting Brackets
0.25" (6.5 mm) XSZB165
0.31" (8 mm) XSZB108
0.47" (12 mm) XSZB112
9006PA12
0.7" (18 mm) XSZB118
9006PA18
1.18" (30 mm) XSZB130
9006PA30
Mounting Nuts
0.31" (8 mm) XSZE108
0.47" (12 mm) XSZE112
0.7" *18 mm) XSZE118
1.18" (30 mm) XSZE130
Minimum Mounting Clearances (mm/inches)
eeedh
IN mm IN mm IN mm IN mm IN mm
XS1L06 0.12 3 0.71 18 0.18 4.5 0.31 8 0 0
XS1D08 0.12 3 0.71 18 0.18 4.5 0.31 8 0 0
XS1D/M12 0.16 4 0.94 24 0.24 6.0 0.47 12 0 0
XS2D12 0.63 16 1.89 48 0.47 12.0 1.42 36 0.31 8
XS1D/M18 0.39 10 2.36 60 0.59 15.0 0.59 15 0 0
XS1D/M30 0.79 20 4.72 120 1.18 30.0 1.18 30 0 0
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
9006PAkk
XSZEkkk
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
BU/3
+
BK/4
PNP
BN/1
BU/3
+
BK/4
NPN
BN/1
BN
BU
3 Wire, NPN, NO
3 Wire, PNP, NO
2 Wire, AC, NO
®
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
Proximity Sensors
XS Tubular Inductive Sensors
Extended Range – AC/DC, DC
©1997- 2002 Schneider Electric All Rights Reserved
258 10/02
Proximity Sensors
XS Tubular Inductive Sensors / Extended Range - AC/DC, DC
Features
Extended range feature available in Universal AC/DC, or DC only sensors, where previously
only available in DC
AC/DC has same extended sensing range as in DC only sensors
Available in moulded cable or connector versions
rugged IP68 Nickel plated brass casing
360° LED for complete visibility
Metal lock nuts included in carton
aSee p. 518 for matching connector cables.
Circuit
Type
Output
Mode
Voltage
Range
Voltage
Drop
Max.
Load
Current
Max.
Operating
Frequency
Max.
Connection aCatalog
Number
6.5mm Diameter, DC, Shielded - Nominal Sensing Distance - 2mm
PNP N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz 2 meter (6’) cable XS1L06PA349
NPN N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz 2 meter (6’) cable XS1L06NA349
PNP N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Nano Style Connector XS1L06PA349S
NPN N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Nano Style Connector XS1L06NA349S
PNP N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Micro Style Connector XS1L06PA349D
NPN N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Micro Style Connector XS1L06NA349D
8mm Diameter, DC, Shielded - Nominal Sensing Distance - 2.5mm
PNP N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz 2 meter (6’) cable XS1N08PA349
NPN N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz 2 meter (6’) cable XS1N08NA349
PNP N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Nano Style Connector XS1N08PA349S
NPN N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Nano Style Connector XS1N08NA349S
PNP N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Micro Style Connector XS1N08PA349D
NPN N.O. 12- 24 Vdc 2.6 V 200 mA 2500 Hz Micro Style Connector XS1N08NA349D
12mm Diameter, DC, Shielded - Nominal Sensing Distance - 4mm
PNP N.O. 12- 24 Vdc 2 V 200 mA 2500 Hz 2 meter (6’) cable XS1N12PA349
NPN N.O. 12- 24 Vdc 2 V 200 mA 2500 Hz 2 meter (6’) cable XS1N12NA349
PNP N.O. 12- 24 Vdc 2 V 200 mA 2500 Hz Micro Style Connector XS1N12PA349D
NPN N.O. 12- 24 Vdc 2 V 200 mA 2500 Hz Micro Style Connector XS1N12NA349D
12mm Diameter, Universal AC/DC, Shielded - Nominal Sensing Distance - 4mm
2 wire N.O. 12- 24 Vdc 5.5 V 200mA 25 Hz /1000 Hz 2 meter (6’) cable XS1M12MA239
2 wire N.O. 12- 24 Vdc 5.5 V 200mA 25 Hz /1000 Hz Micro Style Connector XS1M12MA239K
18mm Diameter, DC, Shielded - Nominal Sensing Distance - 10mm
PNP N.O. 12- 24 Vdc 2 V 200 mA 1000 Hz 2 meter (6’) cable XS1N18PA349
NPN N.O. 12- 24 Vdc 2 V 200 mA 1000 Hz 2 meter (6’) cable XS1N182NA349
PNP N.O. 12- 24 Vdc 2 V 200 mA 1000 Hz Micro Style Connector XS1N18PA349D
NPN N.O. 12- 24 Vdc 2 V 200 mA 1000 Hz Micro Style Connector XS1N18NA349D
18mm Diameter, Universal AC/DC, Shielded - Nominal Sensing Distance - 10mm
2 wire N.O. 12- 24 Vdc 5.5 V 200 mA 25 Hz /1000 Hz 2 meter (6’) cable XS1M18MA239
2 wire N.O. 12- 24 Vdc 5.5 V 200 mA 25 Hz /1000 Hz Micro Style Connector XS1M18MA239K
2 wire N.O. 12- 24 Vdc 5.5 V 200 mA 25 Hz /1000 Hz Mini Style Connector XS1M18MA239A
30mm Diameter, DC, Shielded - Nominal Sensing Distance - 20mm
PNP N.O. 12- 24 Vdc 2 V 200 mA 500 Hz 2 meter (6’) cable XS1N30PA349
NPN N.O. 12- 24 Vdc 2 V 200 mA 500 Hz 2 meter (6’) cable XS1N30NA349
PNP N.O. 12- 24 Vdc 2 V 200 mA 500 Hz Micro Style Connector XS1N30PA349D
NPN N.O. 12 - 24 Vdc 2 V 200 mA 500 Hz Micro Style Connector XS1N30NA349D
30mm Diameter, Universal AC/DC, Shielded - Nominal Sensing Distance - 20mm
2 wire N.O. 24 to 240 V 5.5 V 200 mA 25 Hz /1000 Hz 2 meter (6’) cable XS1M30MA239
2 wire N.O. 24 to 240 V 5.5 V 200 mA 25 Hz /1000 Hz Mini Style Connector XS1M30MA239A
Minimum Mounting Clearances (mm/inches)
6.5 mm 5 mm (.196") 30 mm (1.18") 7.5 mm (.29") d = 10 mm (.393") h = 1.6 mm (.062") d = 6.5 mm (.255") x = 1.3 mm (.051")
8 mm 5 mm (.196") 30 mm (1.19") 7.5 mm (.29") d = 10 mm (.393") h = 1.6 mm (.062") d = 8 mm (.314") x = 1.6 mm (.062")
12 mm 8 mm (.314") 48 mm (1.88") 12 mm (.47") d = 14 mm (.551") h = 2.4 mm (.094") d = 12 mm (.472") x = 1.6 mm (.062")
12 mm (AC/DC) 8 mm (.314") 48 mm (1.88") 12 mm (.47") d = 14 mm (.551") h = 1.2 mm (.047") d = 12 mm (.472") x = 1.6 mm (.062")
18 mm 20 mm (.787") 96 mm (3.77") 30 mm (1.18") d = 28 mm (1.10") h = 3.6 mm (.141") d = 18 mm (.708") x = 3.6 mm (.141")
18 mm (AC/DC) 20 mm (.787") 96 mm (3.77") 30 mm (1.18") d = 28 mm (1.10") h = 1.8 mm (.070") d = 18 mm (.708") x = 1.8 mm (.070")
30 mm 40 mm (1.57") 240 mm (9.44") 60 mm (2.36") d = 50 mm (1.96") h = 6 mm (.236") d = 30 mm (1.18") x = 6 mm (.236")
fFor 6.5mm diameter, b = smooth length
a
AC/DC DC
mm in. mm in.
6.5
mm
Cabled version 33 1.29
Nano connector 42 1.65
Micro connector 45 1.77
8 mm
Cabled version 33 1.29
Nano connector 42 1.65
Micro connector 45 1.77
12 mm Cabled version 50 1.96 33 1.29
Micro connector 61 2.4 48 1.88
18 mm
Cabled version 60 2.36 33.5 1.31
Micro connector 70 2.75 48 1.88
Mini connector
30 mm Cabled version 60 2.36 40.5 1.59
Micro connector 70 2.75 50 1.96
bf
AC/DC DC
mm in. mm in.
6.5
mm
Cabled version 30 1.18
Nano connector 34 1.33
Micro connector 24 0.94
8 mm
Cabled version 26 1.02
Nano connector 26 1.02
Micro connector 24 0.94
12 mm Cabled version 42 1.65 26 1.02
Micro connector 40 1.57 25 0.98
18 mm
Cabled version 51.5 2.02 26 1.02
Micro connector 51.5 2.02 26 1.02
Mini connector
30 mm Cabled version 51.5 2.02 32 1.25
Micro connector 51.5 2.02 32 1.25
b
a
a = Overall Length (mm)
b = Threaded Section (mm)
thread
M18x1
thread
M12x1
thread
M8x1
Mounting in a metal support
D
H
Facing a metal object
e
Side by side
e
Face to face
e
Mounted in a metal support
DX
Proximity Sensors
XS Tubular Inductive Sensors
Extended Range – AC/DC, DC
259
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Sensors / Extended Range - AC/DC, DC
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Options
Accessories
Mechanical 6.5 mm 8 mm 12 mm 18 mm 30 mm
Usable sensing range a0 to 0.08"
(0 to 2 mm)
0 to 0.08"
(0 to 2 mm)
0 to 0.12"
(0 to 3.2 mm)
0 to 0.31"
(0 to 8 mm)
0 to 0.62"
(0 to 16 mm)
Temperature range -13 F to + 25 F (-25 C to +70 C)
Enclosure rating NEMA Type 3, 4x, 6p, 12, 13
IEC Type IP68 (except connectors)
Max tightening torque -- 5 N•m 3.7 (lb-ft) 6 N•m 4.4 (lb-ft) 15 N•m 11 (lb-ft) 40 N•m 29.5 (lb-ft)
Vibration 25 G, amplitude +/- 2mm, f = 10 - 55 Hz
Shock resistance 50 G, duration 11ms”
Standard target size (steel) (mm) 6.5x6.5x1 8x8x1 12x12x1 18x18x1 30x30x1
Max Differential (% of Sr) 15%
Max Repeatability (% of Sr) 3%
LED indicator type Cable 360° ring LED, visible from all quadrants
Connector One LED, visible from 4 quadrants
Enclosure material Nickel plated brass
Wiring 27 AWG 27 AWG 22 AWG 22 AWG 22 AWG
Cable material PvR PvR PvR PvR PvR
Electrical
AC / DC AC / DC AC / DC
Voltage range 24 V to 240 Vac/dc, 12 V to 24 Vdc
Voltage limit (including ripple) 20 V to 264 Vac/dc, 10 to 38 Vdc
Voltage Drop (max.) 2.6 V 2.6 V 5.5 V / 2.6 V 5.5 V / 2 V 5.5 V / 2 V
Max. Leakage (Residual) Current -open state, AC -- -- 0.8 mA 0.8 mA 0.8 mA
Current Consumption (no load) 10 mA
Power-up delay (max.) 5 ms 5 ms 20ms / 5 ms 25 ms / 5 ms 25 ms / 5 ms
On delay (max.) 0.2 ms 0.2 ms 0.5 ms / 0.2 ms 0.5 ms 0.3 ms 0.5 ms / 0.6 ms
Off delay (max.) 0.2 ms 0.2 ms 0.2 ms 0.5 ms / 0.7 ms 2 ms / 1.4 ms
Protective Circuitry
Short circuit protection yes
Overload protection yes
Reverse polarity protection yes
Radio frequency immunity
(RFI) IEC 61000-4-3 Level 3
Electrostatic, Transients,
Impulse IEC 61000-4-2 Level 3; IEC 61000-4-4 Level 3; 60947.5.2 Level 3
Agency Listings
Description Suffix
16.4 ft. (5 meter) cable L2
32.8 ft. (10 meter) cable L5
Description For Sensor Diameter Catalog Number
Mounting Brackets
0.25" (6.5 mm) XSZB165
0.31" (8 mm) XSZB108
0.47" (12 mm) XSZB112
9006PA12
0.7’ (18 mm) XSZB118
9006PA18
1.18" (30 mm) XSZB130
9006PA30
Mounting Nuts
0.31" (8 mm) XSZE108
0.47" (12 mm) XSZE112
XSZE118
0.7’ (18 mm) XSZE130
XSZB1kk
9006PAkk
XSZEkkk
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables
(M8 or S suffix; M12 or D suffix;
U20 or K suffix; U78 or A suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZCA901Y Mini Conn., 3 pin, 2 m, straight
XSZCA911Y Mini Conn., 3 pin, 2 m, 90°
Wiring
Connector
Micro Mini Cable
Blue BU –
Brown BN +
Black BK Output
Connector
Nano Micro Cable
Blue BU –
Brown BN +
Black BK Output
1
3
2
13
2
wire color/connector pin
2 wire, AC/DC for connector version only
BN/2 L1
+/-
L2
-/+
BU/3
AC/DC
31
4
12
43
BK/4 NO
BK/2 NC BK/4 NO
BK/2 NC
3 wire, DC, NO or NC
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
®
Proximity Sensors
XS Inductive Sensors
18 mm, Ferrous Only - DC
©1997- 2002 Schneider Electric All Rights Reserved
260 10/02
Proximity Sensors
XS Inductiv e Sensors / 18 mm, Ferrous Only - DC
Features:
Ideal for machining, sorting applications
Responds only to ferrous metals, ignoring non ferrous metals such as Aluminum
Stainless steel body
Cable and micro-style connector versions offered t
t See p. 518 for matching connector cables
Circuit
Type
Output
Mode
Voltage
Range
Load Current
Max.
Operating
Frequency Max.
Catalog
Number
Shielded - 2 meter (6.6’) cable - Nominal Sensing Distance - 5 mm
PNP N.O. 12-24 Vdc 200 mA 1000 Hz XS1M18PAS40
Shielded - micro-style connector t - Nominal Sensing Distance - 5 mm
PNP N.O. 12-24 Vdc 200 mA 1000 Hz XS1M18PAS40D
Minimum Mounting Clearances (mm/inches)
e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0
2.02
51.5
2.36
60
LED
2.75
70
2.02
51.5
LED
Dual Dimensions inches
mm
thread
M18x1
XS1M18PAS40
XS1M18PAS40D
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
Proximity Sensors
XS Inductive Sensors
18 mm, Ferrous Only - DC
261
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductiv e Sensors / 18 mm, Ferrous Only - DC
Specifications
aRefer to p. 351 for target material correction coefficient Km
Mechanical
Usable sensing range a 0 - 4 mm (.16")
Temperature range -13° to 158° F (-25° to 70° C)
Enclosure rating IEC Type IP68 (except connector version)
Tightening torque (max.) 50 N•m 37 (lb-ft)
Standard target size (steel) 18 x 18 x 1
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type Cable version 360° ring LED
Connector version 4 LED windows at 90 degrees
Enclosure Material Stainless steel
Wiring 22 AWG (0.34 mm2), PvR cable
Electrical
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch, closed state) 2.6 V
Current Consumption (no load) 15 mA
Maximum Load Current 200 mA
Power-up delay (max.) 5 ms
On delay (max.) 0.3 ms
Off delay (max.) 0.7 ms
Protective Circuitry
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
Radio frequency immunity (RFI) Yes
Electrostatic discharges Yes
Fast transients (motor start/stop interference) Yes
Impulse voltages (lightning, etc.) Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40+ C (-40+ F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Stainless steel mounting nuts XSZE318
Mounting bracket, 90° steel 9006PA18
Mounting bracket, plastic XSZB118
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 7428
Stainless 74282
For additional cable options and lengths see p. 518
ccessories. . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
9006PAkk
7428k
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
3 Wire, PNP, NO
12
43
BK/4 NO
BN/1
BU/3
+
-
PNP
®
Proximity Sensors
XS Inductive Sensors
18 mm, Non Ferrous Only - DC
©1997- 2002 Schneider Electric All Rights Reserved
262 10/02
Proximity Sensors
XS Inductive Sensors / 18 mm, Non Ferrous Only - DC
Features:
Response to non ferrous metals only, such as Aluminum, ignoring ferrous material
such as steel
Ideal for mounting in areas where metal is close
Stainless steel body
Cable and micro-style connector versions offered t
t See p.518 for matching connector cables
Circuit
Type
Output
Mode
Voltage
Range
Load Current
Max.
Operating
Frequency Max.
Catalog
Number
Shielded - 2 meter (6’) cable - Nominal Sensing Distance - 5 mm
PNP N.O. 12-24 Vdc 200 mA 1000 Hz XS1M18PAS20
Shielded - micro-style connector t - Nominal Sensing Distance - 5mm
PNP N.O. 12-24 Vdc 200 mA 1000 Hz XS1M18PAS20D
Minimum Mounting Clearances (mm/inches)
e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0
2.02
51.5
2.36
60
LED
2.75
70
2.02
51.5
LED
Dual Dimensions inches
mm
thread
M18x1
XS1M18PAS20
XS1M18PAS20D
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
Proximity Sensors
XS Inductive Sensors
18 mm, Non Ferrous Only - DC
263
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductive Sensors / 18 mm, Non Ferrous Only - DC
Specifications
aRefer to p. 351 for target material correction coefficient Km
Mechanical
Usable sensing range a0 - 4 mm (.16")
Temperature range -13° to 158° F (-25° to 70° C)
Enclosure rating IEC Type IP68 (except connector version)
Tightening torque (max.) 50 N•m 37 (lb-ft)
Standard target size (aluminum) 18 x 18 x 1
Differential (% of Sr) 15%
Repeatability (% of Sr) 3%
LED indicator type Cable version 360° ring LED
Connector version 4 LED windows at 90 degrees
Enclosure material Metal
Wiring 22 AWG (0.34 mm2), PvR cable
Electrical
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 38 Vdc
Voltage drop (across switch, closed state) 2.6 V
Current Consumption (no load) 15 mA
Maximum Load Current 200 mA
Power-up delay (max.) 5 ms
On delay (max.) 0.3 ms
Off delay (max.) 0.7 ms
Protective Circuitry
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
Radio frequency immunity (RFI) Yes
Electrostatic discharges Yes
Fast transients (motor start/stop interference) Yes
Impulse voltages (lightning, etc.) Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range (cable type only) Down to -40° C (-40° F) TF
Extended cable length 16.4 ft. (5 meter) cable L1
32.8 ft. (10 meter) cable L2
Accessories
Description Catalog Number
Stainless steel mounting nuts XSZE318
Mounting bracket, 90° steel 9006PA18
Mounting bracket, plastic XSZB118
0.5" NPT conduit adapter length 2" (50.8 mm) Aluminum 7428
Stainless 74282
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZB1kk
9006PAkk
7428k
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
3 Wire, PNP, NO
12
43
BK/4 NO
BN/1
BU/3
+
-
PNP
®
Proximity Sensors
XS Inductive Sensors
Ferrous/Non-Ferrous; Universal, DC
©1997- 2002 Schneider Electric All Rights Reserved
264 10/02
Proximity Sensors
XS Inductive Sensors / Ferrous/Non-Ferrous ; Universal, DC
Features
Detects all types of metals at the same sensing distance, whereas, metals such as
aluminum and copper require standard sensor to be closer (see chart on next page).
Body types include 18 mm nickel plated brass housing, 30 mm stainless steel housing, and
limit switch style in plastic housing.
All are suitable for flush mounting in metal.
Ideal for “drop in” replacements for tubular and limit switch style standard sensors.
Universal selectable output: PNP, NPN, N.O. and N.C.
Available with 2 meter cable, micro style connector or 2.6' pigtail with micro connector for
very aggressive chemical environments.
Tubular bodies have 360° visibility LED (four LED windows at 90° for connector version).
Metal mounting nuts included with tubular versions.
UL Listed, CSA Certified and CE Mark.
t See p. 518 for matching connector cables
Sensing
Distance
Circuit
Type
Output
Mode
Voltage
Range Connection
Load
Current
Max
Operating
Frequency Catalog Number
Shielded, 18 mm Diameter
5 mm PNP/NPN N.O./N.C. 12-24 Vdc 2 m (6.6’) cable 200 mA 1000 Hz XS1M18KPM40
5 mm PNP/NPN N.O./N.C. 12-24 Vdc Micro Style DC Connector t 200 mA 1000 Hz XS1M18KPM40D
Shielded, 30 mm Diameter
10 mm PNP/NPN N.O./N.C. 12-24 Vdc 2 m (6.6’) cable 200 mA 1000 Hz XS1M30KPM40
10 mm PNP/NPN N.O./N.C. 12-24 Vdc Micro Style DC Connector, 0.8 m
(2.6’) pigtail t200 mA 1000 Hz XS1M30KPM40LD
Shielded, Limit Switch Style Body
15 mm PNP/NPN N.O./N.C. 12-24 Vdc Screw Terminal 200 mA 1000 Hz XS7C40KPM40
Minimum Mounting Clearances (mm/inches)
2.02
51.5 2.75
70
LED
1.57
40
1.57
40
1.77
45
4.6
117
1.18
30
1.57
40
2.36
60
XS1M30KPM40LD
2.02
51.5 2.75
70
4 x 90° LED
XS1M18KPM40D
2.02
51.5 2.36
60
LED
XS1M30KPM40
2.02
51.5 2.36
60
LED
XS1M18KPM40
(1) Output LED (Yellow)
(2) 0.5" NPT conduit opening
(3) Oblong mounting hole:
0.21" x 0.28"
(5.3mm x 7mm)
Dual Dimensions inches
mm
thread
M30x1.5
thread
M18x1
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
ee
XS7C40KPM40 e = 1.57 in. (40 mm) e = 4.72 in. (120 mm)
e
e = 1.77 in. (45 mm)
e = 0.40 in. (10 mm)
e = 0.79 in. (20 mm)
e = 2.36 in. (60 mm)
e = 4.72 in. (120 mm)
e = 0.59 in. (15 mm)
e = 1.18 in. (30 mm
d = 0.71 in. (18 mm), h = 0
d = 1.18 in. (30 mm), h = 0
XS1M18
XS1M30
Proximity Sensors
XS Inductive Sensors
Ferrous/Non-Ferrous; Universal, DC
265
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductive Sensors / Ferrous/Non-Ferrous ; Universal, DC
Specifications
Accessories
Standard sensor technology requires an
adjustment of up to 70% of the sensing
distance to detect various metals. Because the
Ferrous/Non-Ferrous sensor detects all
metals at the same distance, compensation is
no longer needed. A smaller device can now
perform at a range comparable to a larger
sized or non-shielded device.
Mechanical
Standard Temperature Range 32° to 122° F (0° to 50° C)
Enclosure Rating
NEMA Type
IEC Type
Tubular, cable3, 4X, 6P, 12,13
Tubular, connector See connector rating
Limit switch body 4, 6P, 12
Tubular, cable IEC IP68
Tubular, connectorSee connector rating
Limit Switch BodyIEC IP67
Enclosure Material Case
XS1M18 Nickel Plated Brass
XS1M30 Stainless Steel
XS7 ABS Plastic
Tightening torque (max.) XS1M1835 N•m
XS1M3050 N•m
Vibration resistance (IEC 60068-2-6) 7 gn, amplitude ± 1mm (f = 10 Hz to 42 Hz)
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
Standard Target Size
0.7" (18 mm)
1.18" (30 mm)
Limit switch
0.7" x 0.7" (18 mm x 18 mm)
1.18" x 1.18" (30 mm x 30 mm)
1.77" x 1.77" (45 mm x 45 mm)
Differential (max) (% of Sr.) 15%
Repeatability (max) (% of Sr.) 3%
LED indicator type
Tubular, cable
Tubular, connector
Tubular, pigtail
Limit switch body
360° ring LED
4 LED windows at 90°
360° ring LED
LED power On
Connection
10.7" (8 mm) cable
0.7" (18 mm) connector
1.18" (30 mm) cable
1.18" (30 mm) pigtail
Limit switch body
4 wire #22 AWG (0.34 mm2), PvR
4 pin Micro Style DC
4 wire #22 AWG (0.34 mm2), PvR
4 pin Micro Style DC, 0.8 m (2.6’) pigtail, PvR
#14 AWG Screw Terminals
Electrical
Voltage Range
Voltage Limit (including ripple)
12 - 24 Vdc
10 - 38 Vdc
Voltage Drop (across switch) closed state (max) 2.6 V
Current consumption (no load) (max) 15 mA
Load Current (max) 200 mA
Operating frequency (max) 1000 Hz.
On delay (max) 0.3 ms
Off delay (max) 0.7 ms
Power-up delay (max) 5 ms
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
Protective circuitry Radio Frequency Immunity (RFI)
Electrostatic, Transients, Impulse IEC 60947-5-2 and NEMA ICS 5, Part 4
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Size Description Catalog Number
18 mm Metal mounting nuts XSZE118
18 mm Metal mounting bracket 9006PA18
18 mm Plastic mounting bracket XSZB118
30 mm Stainless steel mounting nuts XSZE330
30 mm Metal mounting bracket 9006PA30
30 mm Plastic mounting bracket XSZB130
XSZB1kk
9006PAkk
XSZEkkk
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
4 wire programmable
NO or NC selectable output
BN/1 (NO), BU/3 (NC)
BN/1 (NO), BU/3 (NC)
+
-
BK/4
BK/4
WH/2
WH/2
BU/3 (NO), BN/1 (NC)
BU/3 (NO), BN/1 (NC)
PNP
+
-
NPN
®
0
10
20
30
40
50
60
70
80
90
100
Mag.
Steel
304
Stainless
Steel
Alu Cu
std
Fe/NFe
Standard vs. Fe/NonFe Prox
Sensing Range (%)
Proximity Sensors
XS5L8 Inductive Sensors
Miniature, Rectangular, DC
©1997- 2002 Schneider Electric All Rights Reserved
266 10/02
Proximity Sensors
XS5L8 Inductive Sensors / Miniature , Rectangular, DC
Features:
90 degree sensing, for mounting in restricted spaces with face at end or center
PNP/NPN, N.O. Output
360° ring or LED indicator visible from 4 quadrants
Small, 0.13" x 0.13" x 1.7" (8 mm x 8 mm x 43 mm) square metal housing
Mount side by side with no interference
UL Listed and CSA Certified
t See p. 518 for matching connector cables
Sensing
Face
Circuit
Type
Output
Mode
Voltage
Range
Max.
Load
Current
Max.
Operating
Frequency
Max.
Catalog
Number
1.5 mm Nominal Sensing Distance, 2 M (6.6’) cable
Top PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81PA140
Top NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81NA140
1.5 mm Sensing Distance, Nano style Connector t
Top PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81PA140S
Top NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81NA140S
1.5 mm Nominal Sensing Distance, 2 M (6.6’) cable
Center PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82PA140
Center NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82NA140
1.5 mm Sensing Distance, Nano style Connector t
Center PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82PA140S
Center NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82NA140S
Minimum Mounting Clearances
Dimensions
XS5L81••S
XS5L82
XS5L82•••S
XS5L81
0.7"
18 mm
0"
0 mm
.31
8
1.69
43
.18
4.7==
LED LEDS
M8
1.93
49
.79
20
.39
10
.12
3
2 x M3
XS5L81/82 XS5 L81/82kkk
Dual Dimensions inches
mm
Proximity Sensors
XS5L8 Inductive Sensors
Miniature, Rectangular, DC
267
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS5L8 Indu ctive Sensors / Miniature, Rectan gular, DC
Specifications
a Refer to p. 351 for target material correction coefficient Km
Mechanical
Usable sensing range a 1.2 mm
Temperature range -13° to 158° F (-25° to 70° C)
Enclosure rating IEC Type IP67 (connector version depends on connector)
Differential (% of Sr) 20%
Repeatability (% of Sr) 3%
LED indicator Cable Type 360° ring
Connector type 90°, or visible from 4 quadrants
Enclosure material Metal
Wiring 27 AWG (0.11 mm2), PvR cable
Electrical
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 30 Vdc
Voltage drop (across switch, closed state) 2.6 V
Maximum Load Current 100 mA
Current consumption (max.)(no load) 10 mA
Residual (leakage) current, open state 0.1 mA
Power-up delay (max.) 5 ms
On delay (max.) 0.5 ms
Off delay (max.) 1 ms
Physical Characteristics
Protective Circuitry
Short circuit protection yes
Overload protection yes
Reverse polarity protection yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
5 meter (16’) Cable L1
10 meter (33’) Cable L2
For additional cable options and lengths see p. 518
Connector Cables (M8 or S suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
13
4
BK/4 NO
BK/4 NO
BN/1
BU/3
+
-
PNP
BU/3
+
-
NPN
BN/1
3 Wire, PNP, NO
3 Wire, NPN, NO
®
Proximity Sensors
XS7/8H Miniature, Inductive Sensor
Sub-compact Block Style, DC
©1997- 2002 Schneider Electric All Rights Reserved
268 10/02
Proximity Sensors
XS7/8H Min iature, Induc tive Sen sor / Dub-compact Block Style, DC
Miniature micro switch type inductive proximity sensor for industrial applications.
Features:
Very fast response time
Rugged plastic housing
Extremely small for mounting in difficult to access locations
Easy replacement of mechanical micro-switches with matching footprint (V3)
Longer life and substantially faster speed than mechanical switches
High levels of radio frequency immunity (RFI), electrostatic discharge, fast transients and
impulse voltage protected
UL Listed, CSA Certified and CE Mark
Circuit type Output mode Voltage range Load current (max.) Operating
frequency Catalog Number
2 mm (.078") sensing range – Shielded
DC models, 3 wire 2 m (6.6’) cable
PNP N.O. 10-30 Vdc 200 mA 5000 Hz XS7H10PA340
NPN N.O. 10-30 Vdc 200 mA 5000 Hz XS7H10NA340
3 mm (.118") sensing range – Non-shielded
DC models, 3 wire 2 m (6.6’) cable
PNP N.O. 10-30 Vdc 200 mA 5000 Hz XS8H10PA340
NPN N.O. 10-30 Vdc 200 mA 5000 Hz XS8H10NA340
Minimum Mounting Clearances (mm/inches)
XS7 Shielded e: 7/.27 e: 30/1.18 e: 7/.27 e: 0/0
XS8 Non-shielded e: 10/.39 e: 40/1.57 e: 10/.39 e: 5/.19
1.10
28
.88
22.5
.11
2.8
¯ .12
¯ 3.1
.11
2.75
.14
3.5
.12
3.1
.62
16
.40
10.3
¯ .11
¯ 3
LED
.39
10.1
.23
6
Front View
Dual Dimensions inches
mm
Side by side Face to face Facing a metal object
e
Mounting in a metal support
e
e
e
Proximity Sensors
XS7/8H Miniature, Inductive Sensor
Sub-compact Block Style, DC
269
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS7/8H Min iature, Induc tive Sen sor / Sub-compact Block Style, D C
Specifications
Note: Refer to page 351 for target material correction coefficient Km.
Mechanical
Usable sensing range Shielded 0-1.6 mm (0.06")
Non-shielded 0-2.4 mm (0.19")
Standard temperature range Shielded -13° F to +158° F (-25° C to +70° C)
Non-shielded +14° F to +122° F (-10° C to +50° C)
Enclosure rating IEC Type IP67
Vibration resistance 25 G, Amplitude +/- 2 mm, f = 10-55 Hz
Standard target size (steel) Shielded 0.08" x 0.08" x 0.04" (2 mm x 2 mm x 1 mm)
Non-shielded 0.12" x 0.12" x 0.04" (3 mm x 3 mm x 1 mm)
Repeatability (% of Sr) 3%
Cable 22 AWG, PvR
Electrical
Differential (% of Sr) Maximum 15%
Voltage drop (across switch) 2 V
Current Consumption (no load) 10 mA
On and off delay (maximum) .1 ms
Power-up delay 5 ms
Reverse polarity protection Standard
Protective circuitry
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic: transients: impulse IEC 61000-4-2 Level 2: IEC 61000-4-4 Level 4:
IEC 60947.5.2
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
5 meter (16’) Cable L1
10 meter (33’) Cable L2
Wiring
3 wire, N.O.
BN +
-
BK
BU
PNP
BN +
-
BK
BU
NPN
®
Proximity Sensors
XS7/8G Inductive Sensors
Compact Block Style
©1997- 2002 Schneider Electric All Rights Reserved
270 10/02
Proximity Sensors
XS7/8G Indu ctive Sensors / Compac t Block Style
Features:
Universal AC/DC and DC only models available
Selectable PNP/NPN, N.O. and N.C. output
Compact 0.47" x 1.02" x 1.57" (12 x 26 x 40 mm) body style, for tight mounting spaces
PLC compatible
Rugged plastic housing
Very high Radio Frequency Immunity
Cable or Nano Style Connector versions offered t
UL Listed, CSA Certified and CE Mark
c0.6 Amp fuse is recommended for devices without short circuit protection. See accessories p. 298.
t See p. 518 for matching connector cables
Minimum Mounting Clearances
Circuit
Type
Output
Mode
Volt age
Range
Max.
Voltage
Drop
Max.
Load
Current
Max.
Operating
Frequency
Max.
Catalog
Number
Universal AC/DC, Shielded - 2 meter (6.6’) cable, Nominal Sensing Distance - 2 mm
2 wire N.O. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c25 Hz AC/350 Hz DC XS7G12MA230
2 wire N.C. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c25 Hz AC/350 Hz DC XS7G12MB230
DC, Shielded - 2 meter (6.6’) cable, Nominal Sensing Distance - 2 mm
PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12PA140
NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12NA140
PNP N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 2000 Hz XS7G12PC440
NPN N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 2000 Hz XS7G12NC440
DC, Shielded - Nano Connector, Nominal Sensing Distance - 2 mm t
PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12PA140S
NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12NA140S
Universal AC/DC, Non-shielded - 2 meter (6.6’) cable, Nominal Sensing Distance - 4 mm
2 wire N.O. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c25 Hz AC/350 Hz DC XS8G12MA230
2 wire N.C. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c25 Hz AC/350 Hz DC XS8G12MB230
DC, Non-shielded - 2 meter (6.6) cable, Nominal Sensing Distance - 4 mm
PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12PA140
NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12NA140
PNP N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 1000 Hz XS8G12PC440
NPN N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 1000 Hz XS8G12NC440
DC, Shielded - Nano Connector, Nominal Sensing Distance - 4 mm t
PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12PA140S
NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12NA140S
XS7G Shielded e: 0mm (0") e: 15 mm (.6")
XS8G Non-shielded e: 10 mm (.4") e: 60 mm (2.4")
.15
4.70
18
26
1.02 .15
4
.15
4
(1)
45˚
(2)
.26
32
1.57
40
Ø3.1
.47
12
(3)
.39
10
.67
16
1.18
30
1.22
31
M8
1.77
45
Dual Dimensions inches
mm
(1) 1 elongated hole 3.1 x 5.1mm (0.12" x 0.20")
(2) Cable, L= 2m (6.6’)
(3) 2 holes M= 3 x 5mm (0.12" x 0.20")
XSG12A140S
Side view
Side by side Face to face
e
e
Proximity Sensors
XS7/8G Inductive Sensors
Compact Block Style
271
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS7/8G Indu ctive Sensors / Compac t Block Style
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing range aShielded 0 - 1.6 mm (.06")
Non-shielded 0 - 3.2 mm (.13")
Temperature range -13° to 158° F (-25° to 70° C)
Enclosure rating IEC Type IP67 (except connector style)
Vibration 9conforming to IED 68-2-6) 25 G, amplitude =/-2 mm, f = 10 - 55 Hz
Shock resistance 50 G for 11 ms (conforming to IEC 60068-2-7)
Standard target size (steel) 12 x 12 mm (0.47" x 0.47")
Differential (% of Sr) 20%
Repeatability (% of Sr) 10%
LED indicator Located on top of sensor
Enclosure material Plastic
Wiring 22 AWG (0.34 mm2), PvR cable
Electrical AC/DC models DC models
Voltage range 24 to 240 Vac 12 to 24 Vdc
24 to 210 Vdc --
Voltage limit (including ripple) 20 to 264 Vac/dc 10 to 30 Vdc
Current consumption (max.)(no load) -- 10 mA
Max. Leakage (Residual) Current -open state 0.8 mA at 24 V, 1.5 mA at 120 V 0.1 mA
Power-up delay (max.) 40 ms 4 ms
On delay (max.) 1 ms 0.5 ms
Off delay (max.) 2 ms 1 ms
Protective Circuitry Short circuit protection No Yes
Overload protection No Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range
to +185° F (+85° C) TT
to -40° F (-40° C) TF
5 meter (16') cable length L1
10 meter (33') cable length L2
For additional cable options and lengths see p. 518
Connector Cables (M8 or S suffix)
XSZCS101 Nano Conn., 3 pin, 2 m, straight
XSZCS111 Nano Conn., 3 pin, 2 m, 90°
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
13
4
2-wire AC or DC NO or NC
XSG12M230
BN
BU
+
+
3-wire DC NO
XSG12PA140
XSG12PA140S
BN/1
BU/3
+
BK/4
PNP
XSG12NA140
XSG12NA140S
BN/1
BU/3
+
BK/4
NPN
4-wire DC NO + NC
XSG12PC440
BN/1
BU/3
+
WH(NC)
PNP
BK(NO)
XSG12NC440
BN
BU
+
WH(NC)
NPN BK(NO)
®
Proximity Sensors
XSB Rectangular, Inductive Sensors
Compact Block, AC and DC; Plug-in
©1997- 2002 Schneider Electric All Rights Reserved
272 10/02
Proximity Sensors
XSB Rectangular, Inductive Sensors / Compact Block, AC and DC; Plug-in
Compact long range plug-in inductive proximity sensors for industrial applications.
Features:
Housings: XSB - Plastic (thermoplastic polyester)
Screw terminals or mini style receptacle
Radio Frequency Immunity (RFI)
Noise and transient protection
Reverse polarity protection (DC models)
Selected models are offered with short circuit protection (SCP) and overload protection
UL Listed and CSA Certified. Factory Mutual approved for non incendive applications:
NAMUR sensors approved for intrinsically safe applications. CE mark.
PLC Applications:
P = PLC compatible.
R = Bleeder resistor needed for PLC application.
See p. 518 for matching connector cables.
aFor AC devices without SCP, see p. 298 for protective fuses.
Minimum Mounting Clearances
25mm (.984") sensing range, Plug-in, Non-shielded
Output
Mode
Voltage
Range
Max.
Load
Residual
(leakage)
Current
Operating
Frequency
Current
LED/SCPaCatalog
Number
NAMUR - DC, 2 wire, screw terminals for use with intrinsically safe relays
1mA/3mA 7-12 V - - 250 Hz No/Yes XSBN25122
DC models, 2 wire, screw terminals
N.O. 12-58 V 80 mA 1.2 mA 250 Hz No/No XSBC25710
AC models, 2 wire, screw terminals
N.O. 93-132 V 150 mA 1.7 mA (P)40 H z Yes/ Yes XSBA25513
N.C. 93-132 V 150 mA 1.7 mA (P)40 H z Yes/Ye s XSBA25523
N.O. 40-132 V 270 mA 4.5 mA (P)40 Hz Yes/No XSBA25811
N.C. 40-132 V 270 mA 4.5 mA (P)40 Hz Yes/No XSBA25821
N.O. 93-264 V 150 mA 4.5 mA (R)40 Hz Yes/No XSBA25911
N.C. 93-264 V 150 mA 4.5 mA (R)40 Hz Yes/No XSBA25921
AC models, 2 wire, mini style connector
N.O. 93-132 V 150 mA 1.7 mA (P)40 H z Yes/ Yes XSBA25513R3
N.C. 93-132 V 150 mA 1.7 mA (P)40 H z Yes/Ye s XSBA25523R3
N.O. 93-264 V 150 mA 4.5 mA (P)40 Hz Yes/No XSBA25911R3
N.C. 93-264 V 150 mA 4.5 mA (P)40 Hz Yes/No XSBA25921R3
XSC.15 e: 38mm (1.5") e: 97mm (3.8")
XSC.20 e: 80mm (3.1") e: 160mm (6.3")
5
1.97
50
1/2" NPT
conduit
ent.
2.99
76
1.57
40
1.57
40
2 x 4.2
dia.
5
1.97
50 1.61
41
2 x .16" dia.
Dual Dimensions inches
mm
e
Side by side Face to face
e
NotforUseonNew
ApplicationsLimitedProduct
Availability
Proximity Sensors
XSB Rectangular, Inductive Sensors
Compact Block, AC and DC; Plug-in
273
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XSB Rectangular, Inductive Sensors / Compact Block, AC and DC; Plug-in
Specifications
c Except XSBN25122
aExcept XSBN25122 LR1599C, Class 3218 06
Ex: XSB C25710 TF
qNot available for AC models with SCP.
tRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing ranget0-20 mm (.78")
Standard temperature range -13° F to +158° F (-25° C to +70° C)
Enclosure rating • NEMA Type 3, 4, 6, 13
• IEC Type IP67
Vibration resistance 25 G, amplitude ± 2 mm, f = 10-55 Hz
Shock resistance 50 G for 11 ms
Standard target size (steel) 3" x 3" (75 x 75 mm)
Differential Max. 20%
Repeatability Max. 5%
Radio Frequency Immunity (RFI) Standard
Cable Screw terminals, #16AWG
Electrical AC Models DC Models
Voltage drop (across switch) 9.5 V 7 V
Inrush current (inductive @ 20mS) .9 A
Minimum load current 20 mA 1.5 mA
Power supply current (no load) 10 mA
On delay (max.) 10 ms 0.4 ms
Off delay (max.) 10 ms 1 ms
Power-up delay (max.) 150 ms 1.2 ms
Reverse polarity protection Standard
Agency Listings E 164353 c
CCN NRKH
LR 44087 a
Class 3211 03 FM: J.I. OROH9.AX
(3610, 3611)
Options
Description Suffix
Extended temperature range q
to +185° F (+85° C) TT
to -40° F (-40° C) TF
Replacement modules
Description Output Mode Voltage Range Leakage Current Catalog Number
AC models
Base receptacle - - - ZSBZ21
Switch body N.O. 93-132 Vac 1.7 mA ZSBA25513
Switch body N.C. 93-132 Vac 1.7 mA ZSBA25523
Switch body N.O. 93-132 Vac 4.5 mA ZSBA25911
Switch body N.C. 93-132 Vac 4.5 mA ZSBA25921
DC models
Base receptacle - - - ZSBZ22
Switch body N.O. 12-58 Vac - ZSBC25710
For additional cable options and lengths see p. 518
Connector Cables (A or R3 suffix)
XSZCA901Y Mini Conn., 3 pin, 2 m, straight
XSZCA911Y Mini Conn., 3 pin, 2 m, 90°
W
iring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
31
2
2 wire AC
3
4
NO
1
2
NC
L1
L2
L1
L2
2 wire DC
1
4
NO
+
-
®
NotforUseonNew
ApplicationsLimitedProduct
Availability
Proximity Sensors
XS Inductive Sensors
Cubic Block Style, 26 x 26 mm and 40 x 40 mm Square, DC
©1997- 2002 Schneider Electric All Rights Reserved
274 10/02
Proximity Sensors
XS Inductiv e Sensors / Cubic Block Style, 26 x 26 mm and 40 x 40 mm Squar e, DC
Features
Compact cubed body style in rugged PBT plastic
Flush and Non-flush mountable
Comparable sensing distance to Limit Switch style in half the body size
Mounting bracket included with each sensor
Elbow bracket provides interchangeability with Limit Switch style sensor, and enables
multiple positioning of sensing face
Molded cable or molded cable with Micro connector pigtail at 0.8 m or 0.15 m length
qSee p. 518 for matching connector cables
Minimum Mounting Clearances
Description
Nominal
Sensing
Distance
Circuit
Type
Output
Mode
Voltage
Range
Voltage
Drop
Max.
Load
Current
Max.
Operating
Frequency
Max.
Catalog Number
26 mm x 26 mm
DC, Flush Mountable
2 Meter (6’) Cable q
26 x 26 10 mm 2 wire N.O. 12–48 Vdc 5.2 V 100 mA 100 Hz XS7T2DA210
26 x 26 10 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T2PC440
26 x 26 10 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T2NC440
0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q
26 x 26 10 mm 2 wire N.O. 12–48 Vdc 5.2 V 100 mA 100 Hz XS7T2DA214LD
26 x 26 10 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T2PC440LD
26 x 26 10 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T2NC440LD
0.15 m (5.9 ft) Pigtail with 4 Pin Micro Connector q
26 x 26 10 mm 2 wire N.O. 12–48 Vdc 5.2 V 100 mA 100 Hz XS7T2DA214LD01
DC, Non-Flush Mountable
2 Meter (6’) Cable q
26 x 26 15 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 500 Hz XS8T2PC440
26 x 26 15 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 500 Hz XS8T2NC440
0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q
26 x 26 15 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 500 Hz XS8T2PC440LD
26 x 26 15 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 500 Hz XS8T2NC440LD
40 mm x 40 mm
DC, Flush Mountable
2 Meter (6’) Cable q
40 x 40 15 mm 2 wire N.O. 12–48 Vdc 5.2 V 100 mA 150 Hz XS7T4DA210
40 x 40 15 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T4PC440
40 x 40 15 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T4NC440
0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q
40 x 40 15 mm 2 wire N.O. 12–48 Vdc 5.2 V 100 mA 150 Hz XS7T4DA214LD
40 x 40 15 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T4PC440LD
40 x 40 15 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS7T4NC440LD
0.15 m (5.9 ft) Pigtail with 4 Pin Micro Connector q
40 x 40 15 mm 2 wire N.O. 12–48 Vdc 5.2 V 100 mA 150 Hz XS7T4DA214LD01
DC, Non-Flush Mountable
2 Meter (6’) Cable q
40 x 40 20 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS8T4PC440
40 x 40 20 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS8T4NC440
0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q
40 x 40 20 mm PNP N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS8T4PC440LD
40 x 40 20 mm NPN N.O. + N.C. 12–48 Vdc 2 V 200 mA 1000 Hz XS8T4NC440LD
E1 E2 E3 D1 H
IN mm IN mm IN mm IN mm IN mm
XS7T2 Shielded 0.98 25 4.32 110 1.18 30 1.02 26 0 0
XS7T4 Non-shielded 1.57 40 4.71 120 1.77 45 1.57 40 0 0
XS7T4 Shielded 1.49 38 4.72 120 1.77 45 3.07 78 1.02 26
XS8T4 Non-shielded 2.36 60 6.29 160 2.36 60 4.72 120 1.57 40
1.57
40
1.57
40
1.18
30
1.22
31
1.57
40
2.17
55
.98
25
1.69
43
== Ø5.3
Ø4.2
Ø5.3x8
1.18
30
Ø5.3
Ø5.3x8
Ø3
LED
1.57
40
1.57
40
2.09
53
2.16
55
1.73
44
1.57
40
.94
24
1.73
44
==
1.02
26
1.02
26
.98
25
1.02
26
.67
17
==
LED
LED
1.18
301.73
44
Dual Dimensions inches
mm
E1 E2
D1
H
E3
Side by Side Facing a Metal Object Mounted in a Metal Support
Face to Face
Proximity Sensors
XS Inductive Sensors
Cubic Block Style, 26 x 26 mm and 40 x 40 mm Square, DC
275
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductiv e Sensors / Cubic Block Style, 26 x 26 mm and 40 x 40 mm Squar e, DC
Specifications
aRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable Sensing Range aXS7T2 0–8 mm (.32")
XS8T2 0–12 mm (.47")
Temperature Range -13° to 158° F (-25° to 70° C)
Enclosure Rating NEMA Type 1, 4X, 12
IEC Type IP67 (connector version depends on connector)
Vibration 25 G, amplitude =/-2 mm, f = 10-55 Hz
Shock Resistance 50 G for 11 ms
Differential (% of Sr) 20%
Repeatability (% of Sr) 3%
LED Indicator Type Yes, located at cable
Enclosure Material Plastic
Wiring 20 AWG (0.5 mm2), PvR cable
Electrical 2 wire 3 wire 4 wire
Voltage Range 12–48 Vdc 12–48 Vdc 12–48 Vdc
Voltage Limit (Including Ripple) 10–58 Vdc 10–58 Vdc 10–58 Vdc
Voltage Drop 5.2 V 2 V 5.2 V
(max.) Leakage (Residual) Current–Open State 0.7 mA 0.1 mA 0.1 mA
Current Consumption 10 mA 10 mA 10 mA
Power-up Delay (max.) 5 ms 5 ms 7 ms
On Delay (max.) 2 ms 0.3 ms 0.3 ms
Off Delay (max.) 5 ms 0.7 ms 0.7 ms
Protective Circuitry Short Circuit Protection Yes Yes Yes
Overload Protection Yes Yes Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Mounting options
For additional cable options and lengths see p. 518
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
12
43
WH/2 (N.C.) +
-
PNP BK/4 (N.O.)
WH/2 (N.C.)
+
-
NPN
BK/4 (N.O.)
BN/1
BU/3
BN/1
BU/3
4 Wire
2Wire
BN/1
BU/4
+/-
-/+
®
90°
45°
0
90°
45°
0
M3 x 6 CHCM3 x 6 CHC
M3 x 6 CHC
M3 x 6 CHC
90°
45°
90°
90°
M3 x 6 CHC
90°
45°
M3 x 6 CHC
90°
90°
90°
90°
XS7/8T2
XS7/8T4
Proximity Sensors
XS7/8C Limit Switch Type, Inductive Sensors
5 Position Turret Head, Plastic AC/DC, DC or AC
©1997- 2002 Schneider Electric All Rights Reserved
276 10/02
Proximity Sensors
XS7/8C Limit Switch Type, Inductive Sensors / 5 Position Turrent Head, Plastic AC/DC, DC or AC
Standard limit switch housing inductive proximity sensors for industrial applications.
Features:
PBT plastic body with stainless steel screws for corrosive environments.
Plug-in design for ease in replacement.
5 position turret head for reduced inventory.
0.5" NPT conduit entrance with many wiring and connecting options.
Radio Frequency Immunity (RFI) standard.
PLC compatible.
2 LED system on selected models indicates ON/OFF, POWER ON.
DC versions work with unfiltered power supply
Noise and transient protection
Reverse polarity protection (DC models)
Excellent resistance to aggressive environments (dripping corrosive fluids, submersion
in water).
Universal AC/DC 2 wire
Longest extended range using the standard dimensions
UL listed, CSA certified and CE mark
aFor devices without SCP, an 0.8A quick blow fuse wired in series is recommended, see p. 298 for protective fuses.
c20 Vdc 58 IEC 60947-5-2 Utilization category DC-13: Vdc > IEC 60947-5-2 Utilization category DC-12
Circuit
Type
Output
Mode
Voltage Range Maximum
Load
Current c
Residual
(leakage)
current
Operating
Frequency LED/SCPaCatalog
Number
AC DC
Shielded
15mm (.59") sensing range universal, AC/DC
2 wire N.O./N.C. 24-240 V 24-210 V 300 mA/200 mA 0.5 mA at 24 V
1.5 mA at 120 V 25/50 Hz Yes/No XS7C40MP230
15mm (.59") sensing range, DC
2 wire N.O. - 12-48 V 100 mA 0.5 mA 1500 Hz Yes/Yes XS7C40DA210
2 wire N.O./N.C. - 12-48 V 100 mA 0.5 mA 1500 Hz Yes/Yes XS7C40DP210
PNP N.O. + N.C. - 12-48 V 200 mA - 1000 Hz 2/Yes XS7C40PC440
NPN N.O. + N.C. - 12-48 V 200 mA - 1000 Hz 2/Yes XS7C40NC440
20mm (.79") extended range, DC 3 wire
PNP N.O. + N.C. - 12-48 V 200 mA - 1000 Hz 2/Yes XS7C40PC449
NPN N.O. + N.C. - 12-48 V 200 mA - 1000 Hz 2/Yes XS7C40NC449
15mm (.59") sensing range, AC
2 wire N.O./N.C. 24-240 V - 500 mA 1.5 mA 25 Hz Yes/No XS7C40FP260
Non-shielded
20mm (.79") sensing range universal, AC/DC
2 wire N.O./N.C. 24-240 V 24-210 V 300 mA/200 mA 0.5 mA at 24 V
1.5 mA at 120 V 25/50 Hz Yes/No XS8C40MP230
20mm (.79") sensing range, DC
2 wire N.O. - 12-48 V 100 mA 0.6mA 150 Hz Yes/No XS8C40DA210
2 wire N.O./N.C. - 12-48 V 100 mA 0.6mA 150 Hz Yes/No XS8C40DP210
PNP N.O. + N.C. - 12-48 V 200 mA - 1000 Hz 2/Yes XS8C40PC440
NPN N.O. + N.C. - 12-48 V 200 mA - 1000 Hz 2/Yes XS8C40NC440
40mm (1.6") extended range, DC 3 wire
PNP N.O. + N.C. - 12-48 V 200 mA - 500 Hz 2/Yes XS8C40PC449
NPN N.O. + N.C. - 12-48 V 200 mA - 500 Hz 2/Yes XS8C40NC449
20mm (.79") sensing range, AC
2 wire N.O./N.C. 24-240 V - 500 mA 1.5 mA 25 Hz Yes/No XS8C40FP260
20mm (.79") sensing range, AC Model with Timer (1-20s)
2 wire N.O./N.C. 24-240 V - 350 mA 2.0 mA (R) 13 Hz Yes/No XSCT023319
Minimum Mounting Clearances (mm/inches)
XS7 Shielded e: 40/1.57 e: 120/4.72
XS8 Non-shielded e: 80/3.15 e: 160/6.30
1.57
40
1.57
40
1.77
45
4.6
117
1.18
30
1.57
40
2.36
60
1/2" NPT
conduit ent.
1.57
40
1.57
40
4.5
114.5
LED
1.
1
28
2.36
60
1.18
30
2 x .2" dia.
1.77
45
2 x 5.3mm dia.
XS7/8
XSCT
Sensing head turns to
accommodate 5 different
sensing positions
Dual Dimensions inches
mm
e
Side by side
t t
e
Face to Face
Proximity Sensors
XS7/8C Limit Switch Type, Inductive Sensors
5 Position Turret Head, Plastic AC/DC, DC or AC
277
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS7/8C Limit Switch Type, Inductive Sensors / 5 Position Turrent Head, Plastic AC/DC. DC or AC
Specifications
tSee page 351 for target material corrective coefficient km.
aWithout overload or SCP, an 0.8 A quick blow fuse wired in series is recommended, see page 298 for protective fuses.
Mechanical
Usable sensing
range t
Shielded 0-12 mm (.47")
Non-shielded 0-16 (63")
Standard temperature range -13° F to +158° F (-25° C to +70° C)
Enclosure rating NEMA Type 4, 6P, 12 (UL test pending)
CENELEC Type IP67
Enclosure material Body & sensing face PBT
Screws Stainless Steel
Vibration resistance IEC 60068.2.6 25 G, amplitude at 55 Hz, f = 10-55 Hz
Shock resistance IEC 60068.2.27 50 G duration 11 ms
Standard target size
(steel)
Shielded 45 x 45 mm (1.8" x 1.8")
Non-shielded 60 x 60 mm (2.4" x 2.4")
Differential Max. 20%
Repeatability Max. 3%
Radio Frequency Immunity (RFI) Standard
Cable Screw terminals
Electrical AC Models DC Models AC/DC Models
2 wire 4 wire
Voltage range 24-240 V 50/60 Hz 12-48 V 12-48 V 24-240 Vac 50/60 Hz
24-210 Vdc
Voltage limit (including ripple) 20-264 V 50/60 Hz 10-58 V 10-58 V 20-264 Vac/dc
Voltage drop (across switch) closed state 5.5 V 4 V 2 V 5.5 V
Minimum load current 5 mA 1.5 mA 5 mA
Maximum load current 500 mA 100 mA 100 mA 300 mA/200 mA
Inrush 2Aa––2 Aa
Current consumption (no load) 10 mA
On delay (max.) 30 ms 2 ms 0.3 ms 30 ms
Off delay (max.) Shielded 20 ms 5 ms 0.7 ms 20 ms
Non-shielded 20 ms 7 ms 0.7 ms 20 ms
Power-up delay (max.) 120 ms 5 ms 5 ms 120 ms
Protective circuitry
Short circuit protection Optional a
Overload protection Yes
Radio frequency immunity (RFI) IEC 61000-4-3 Level 3
Electrostatic; Transients; Impulse IEC 61000-4-2 Level 4; IEC 61000-4-3 Level 3; IEC 60947.5.2 Level 3
Reverse polarity protection DC Versions Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Options
Description Suffix
Extended temperature range +185° F (+85° C) TT
Extended temperature range -40° F (-40° C) TF
3 pin mini style connector Normally open R30
3 pin mini style connector Normally closed R31
5 pin mini style connector R5
3 pin micro stye connector AC only, wired Normally open K30
3 pin micro style connector AC only, wired Normally closed K31
For additional cable options and lengths see p. 518
Connector Cables (R3, R5 or K suffix)
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZCA901Y Mini Conn., 3 pin, 2 m, straight
XSZCA911Y Mini Conn., 3 pin, 2 m, 90°
XSZCA1501Y Mini Conn., 5 pin, 2 m, straight
XSZCA1511Y Mini Conn., 5 pin, 2 m, 90°
Wiring
Connector
K30/K31 R30/R31 R5
Cable
Blue BU –
Brown BN +
Black BK Output
1
3
221
13
34
5
2
2 wire DC Non Polarized
5
6
+/-
-/+
NO
NC
4 wire DC NO/NC
1
3
4 (NO) +
-
PNP 2 (NC)
1
3
4 (NO)
+
-
NPN
2 (NC)
PNP
NPN
5
6
2 wire AC
NO/NC Selector Jumper
NO
NC
®
Proximity Sensors
XS Inductive Sensors
Limit Switch Body, 5 Position Turret Head, DC IQ Prox
©1997- 2002 Schneider Electric All Rights Reserved
278 10/02
Proximity Sensors
XS Inductiv e Sensors / Limit Switch Bo dy, 5 Position Turrent Head, DC IQ Prox
Features:
Microprocessor based, self-teaching Proximity Switch adjusts to its environment on command,
suppressing any metal background, then detecting the target it was taught to identify. (See
Illustration).
Can be recessed mounted in metal without interference with sensing field
Long range sensing 0.98" (25 mm)
Plastic Limit Switch plug-in body style with 5 position turret head
Two LEDs: (1) power supply and terminal mode (flashes in learning mode when sensor is
learning its environment), (2) output
24 Vdc, complementary PNP and NPN type output
UL Listed, CSA Certified, CE Mark
Illustrations:
Sensing Distance Circuit Type Output Mode Connection Catalog Number
25 mm PNP N.O. Screw Terminal XS8C40PAA40
25 mm NPN N.O. Screw Terminal XS8C40NAA40
Minimum Mounting Clearances (mm/inches)
XSC8C40AA40 e: 80/3.15 e: 9.45m/240
1.57
40
1.57
40
1.77
45
4.6
117
1.18
30
1.57
40
2.36
60
(1) Output LED (Yellow)
(2) Power/Teach LED (Green)
(3) 1/2" NPT conduit opening
(4) Two elongated mounting holes:
0.21" x 0.28" (5.3 mm x 7 mm)
(2)
(3)
(1)
(4)
Dual Dimensions inches
mm
GN YW GN YW
1. Sensor can be flush mounted, non-flush
mounted or recessed mounted. A metal
background can be placed in immediate
proximity of the sensor.
2. To set up, activate “teach” mode. When
no target is present, sensor will learn the
environment. Then, pass target in front of
the sensor in the usual way.
3. Green LED flashes when sensor is
learning its environment and target, then
becomes steady when sensor is set.
4. The newly programmed sensor will
recognize the target and provide output.
ee
Side by side Face to face
Proximity Sensors
XS Inductive Sensors
Limit Switch Body, 5 Position Turret Head, DC IQ Prox™
279
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductiv e Sensors / Limit Switch Bo dy, 5 Position Turrent Head, DC IQ Prox
Specifications
Activating self-teaching mode
When in the self-teaching mode, the green LED (status) flashes rapidly.
As objects pass through the detection zone, the sensor memorizes the two opposing
thresholds in relation to its environment. When the self-teaching is complete, the green LED
ceases to flash and maintains a steady light. The yellow LED indicates output.
Mechanical
Temperature Range Operating
Storage
-13 ° F to 158 ° F (-25 ° C to 70 ° C)
-13 ° F to 158 ° F (-25 ° C to 70 ° C)
Enclosure Rating NEMA Type 4, 4X, 6, 6P, 12,
IEC Type IEC IP67 per IEC 60529
Enclosure Material Case PBT
Vibration resistance (IEC 60068-2-6) 25 G, amplitude at 55 Hz, f = 10 - 55 Hz
Shock resistance (IEC 60068-2-27) 50 G, duration 11 ms
Differential (max.) (% of Sr.) 15%
Repeatability (max.) (% of Sr.) 3%
LED indicator type Power/Teach (green)
Output (yellow)
Connection Screw Terminal
Electrical
Voltage Limit (including ripple) 19 - 30 Vdc
Voltage Drop (across switch) closed state (max.) 2 V
Current consumption (no load) (max.) 20 mA
Load Current (max.) 200 mA
Operating frequency (max.) 600 Hz
On delay (max.) 1 ms
Off delay (max.) 1 ms
Power-up delay (max.) 250 ms
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
Agency Listings E 164869
CCN NRKH
CR 44087
Class 3211 03
Wiring
XS8C40kAA40
3-wire DC, NO output
1
1
+
-
4
4
3
3
PNP
+
-
NPN
BN
BK
BU
BN
BK
BU
®
Option 1
by external contact
Option 2
internally (repositioning of jumper)
1
External
contact (pulse)
2
3
+
-
or
Proximity Sensors
XSD Rectangular, Inductive Sensors
Long Range Block, AC and DC – Plug-in
©1997- 2002 Schneider Electric All Rights Reserved
280 10/02
Proximity Sensors
XSD Rectangular, Inductive Sensors / Long Rang e Block, AC and C - Plug-in
Features
Rectangular low profile switch 3.5" square by 1.63" high ( 88.4 x 41.4 mm) designed for very
demanding industrial applications.
Housings: Plastic (thermoplastic polyester)
LED indicators: target sensed, power on and short circuit (selected models)
Timer model available for jamming applications
Plug-in modular design
Radio Frequency Immunity (RFI)
Short circuit protection (SCP) (selected models)
Alternate frequency models for side by side mounting (selected models)
DC models: complementary outputs (PNP or NPN)
AC models: selectable normally open (N.O.) or normally closed (N.C.)
UL Listed, CSA Certified and CE marked
k100 mA for DC.
cPLC applications: P= PLC compatible. R= Bleeder resistor needed.
jAlso available with alternate frequency. Add F to catalog number. No additional charge.
f1 LED for power ON, 1 LED for output ON, 1 LED for SCP triggered.
lMating connector see p. 518.
aFor devices without SCP, see p. 298 for protective fuses.
40 mm (1.57") Sensing Range, Shielded
Circuit
Type
Output
Mode
Voltage
Range q
Max.
Load
Residual
(Leakage)
Current
Operating
Frequency
Maximum
LED/SCPaCatalog
Number
DC Model, Screw Terminals
2 wire N.O. 12-48 V 100 mA 0.5 mA 180 Hz Yes XSDC407138
40 mm (1.57") Sensing Range, Non-shielded
DC Model, Screw Terminals
2 wire N.O. 12-48 V 100 mA 0.5 mA 180 Hz Yes/Yes XSDC407139
PNP N.O. + N.C. 12-48 V 200 mA 50 Hz Yes/Yes XSDH407339j
NPN N.O. + N.C. 12-48 V 200 mA 50 Hz Yes/Yes XSDJ407339j
AC Model, Screw Terminals
2 wire N.O.,N.C. 24-240 V 500 mA 1.5 mA (P) c10 Hz Yes/No XSDA400519j
2 wire N.O.,N.C. 24-240 V 500 mA 1.5 mA (P) c10 Hz 3f/Yes XSDA405539j
AC Model Mini Style Connector, 3 Pins l
2 wire N.O.,N.C. 24-240 V 500 mA 1.5 mA (P) c10 Hz Yes/No XSDA400519R3j
2 wire N.O.,N.C. 24-240 V 500 mA 1.5 mA (P) c10 Hz 3f/Yes XSDA405539R3j
AC Model with Timer
2 wire N.O.,N.C. 24-240 V 500 mA 3.5 mA (R) c10 Hz Yes/No XSDT023319
50 mm (2") Sensing Range, Shielded
AC/DC Model, Screw Terminals
2 wire N.O./N.C. 24-240 V 5-100 mA DC
5-500 mA AC
1.7mA at 120V
3 mA at 240V k10 Hz 3f/Yes XSDM500538
50 mm (2") Sensing Range, Non-shielded
DC Model, Screw Terminals
2 wire N.O. 12-48 V 100 mA 0.5 mA 180 Hz Yes/Yes XSDC507139
AC Model, Screw Terminals
2 wire N.O./N.C. 24-240 V 500 mA 1.5 mA 10 Hz Yes/No XSDA500519
2 wire N.O./N.C. 24-240 V 500 mA 1.5 mA 10 Hz 3f/Yes XSDA505539
AC Model Mini Style Connector, 3 Pins l
2 wire N.O/.N.C. 24-240 V 500 mA 1.5 mA 10 Hz Yes/No XSDA500519Rj
2 wire N.O./N.C. 24-240 V 500 mA 1.5 mA 10 Hz 3f/Yes XSDA505539Rj
Minimum Mounting Clearances (Except XSDM500538) (mm/inches)
XSD 40 e: 200/7.9 e: 400/15.7
XSD 50 e: 250/10 e: 500/20
1/2" NPT
conduit ent.
4 x dia. 5.5 mm
4 x dia. .21" LED
3.90
100
1.5
40
2.56
65
2.56
65
.29
7.5
3.10
80
4 x dia. 5.5 mm
4 x dia. .21"
3.98
101
1.5
40
2.96
75
2.56
65
.33
8.5
3.23
82
Unshielded
Shielded
Dual Dimensions inches
mm
e
S
ide by side Face to
f
ace
e
Proximity Sensors
XSD Rectangular, Inductive Sensors
Long Range Block, AC and DC – Plug-in
281
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XSD Rectangular, Inductive Sensors / Long Rang e Block, AC and DC - Plug-in
Specifications
a Timer model voltage drop is 4.5 V.
Ex: XSD605539 TTR3
pRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable Sensing Rangea24-48 mm (0.94" - 1.89")
Standard Temperature Range -13° F to +158° F (-25° C to +70° C)
Enclosure Rating NEMA Type 3,4 X (indoor),12,13
IEC Type IP67
Vibration Resistance 25 G, amplitude ± 2 mm, f =10-55 Hz
Shock Resistance 50 G for 11 ms
Standard Target Size (Mild Steel) 120 x 120 mm (4.7" x 4.7")
Differential Maximum 20%
Repeatability Maximum 5%
Cable, PVC Screw Maximum, #16 AWG
Electrical AC Models DC Models AC/DC Models
2 wire 4 wire
Voltage range max. (including ripple) 20-264 V 10-58 V 10-58 V 20-264 V
Voltage Drop (Across Switch) 5.5 Va4 V 1.8 V 6 V
Inrush Current (Inductive @ 20mS) 2 A - - 2 A
Minimum Load Current 5 mA 1.5 mA - 5 mA
Current consumption (No Load) - - 10 mA -
On Delay (max.) 30 ms 0.2 ms 10 ms 40 ms
Off Delay (max.) 20 ms 3 ms 10 ms 60 ms
Power-up Delay (max.) 120 ms 5 ms 10 ms 100 ms
Reverse Polarity Protection - Standard Standard -
Radio Frequency Immunity (RFI) 4 cm (1.6") Minimum from antenna
Agency Listings E 164353 c
CCN NRKH
LR 44087 a
Class 3211 03 FM: J.I. OROH9.AX
(3610, 3611)
Options
Description Suffix
Extended Temperature Rangea
to +185° F (85° C) (p Not Available on AC Models with SCP) TT
to -40° F (-40° C) TF
Replacement Modules
Description Catalog Number
DC 2 Wire
Base Receptacle, N.O. Contact ZSDZ03
N.O. Contact Switch ZSDC607139
Base Receptacle, N.O./N.C. ZSDZ02
N.O./N.C. Contact Switch ZSDC607319
DC 3 Wire
Base Receptacle ZSDZ02
PNP Switch ZSDH607339
NPN Switch ZSDJ607339
AC 2 Wire
Base Receptacle ZSDZ01
1 LED, N.O. SCP Switch ZSDA600519
3 LED, SCP Switch ZSDA605539
AC/DC ZSDM600539
For additional cable options and lengths see p. 518
Connector Cables (A or R3 suffix)
XSZCA901Y Mini Conn., 3 pin, 2 m, straight
XSZCA911Y Mini Conn., 3 pin, 2 m, 90°
W
iring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
13
2
3 wire DC, NO/NC
1
3
4 (NO)
+
-
PNP
2 (NC)
1
3
4 (NO)
+
-
NPN
2 (NC)
2 wire DC, non polarized
3
4
+/-
-/+
NO
3
4
+/-
-/+
2 wire AC and AC/DC,
programmable NO/NC
L1
7NO
8
7NC
load
8
L2
NC
®
Proximity Sensors
XSD Rectangular, Inductive Sensors
Long Range Block, AC and DC; Adjustable Sensing Range
©1997- 2002 Schneider Electric All Rights Reserved
282 10/02
Proximity Sensors
XSD Rectangular, Inductive Sensors / Long Rang e Block, AC and DC; Adjustable Sensing Range
Features:
Rectangular low profile switch 3.5" square by 1.63" high ( 88.4 x 41.4 mm) designed for very
demanding industrial applications. Especially recommended for long sensing range
applications with metal in the background.
Housings: Plastic (thermoplastic polyester)
Adjustable sensing range (30 to 60mm); sensitivity can be decreased below the maximum
usable sensing distance (48mm) to cancel the metal background influence (20 turn
potentiometer under the front plastic cap). For fixed long sensing distance, see page 280.
LED indicators: target sensed, power on and short circuit (selected models)
Plug-in modular design
AC/DC model available
Radio Frequency Immunity (RFI)
Short Circuit Protection (SCP) (selected models)
1/2" NPT conduit entrance
Protected, captive saddle clamp terminals in ready-to-wire position
DC models: complementary outputs PNP or NPN
AC models: programmable output N.O./N.C.
UL Listed and CSA Certified
NOTE: Sensors are delivered and adjusted from the factory for maximum sensing distance.
Do not attempt to increase the sensing distance above the factory setting; sensor
behavior becomes unpredictable.
PLC compatible.
1 LED for power OUT and 1 LED for output ON, 1 LED for SCP triggered.
c< 1 mA @ 24 V, < 3 mA @ 240 V
aFor devices without SCP, see p. 298 for protective fuses.
30-60 mm (2.36") sensing range, Non-shielded
Circuit
Type
Output
Mode
Voltage
Range
Max.
Load
Residual
(leakage)
Current Max
Operating
Frequency
Maximum
LED/SCPaCatalog
Number
DC model, 2 and 3 wire screw terminals
2 wire N.O. 12-48 V 100 mA 0.8 mA 20 Hz Yes/Yes XSDC607139
2 wire N.O.,N.C. 12-48 V 100 mA 0.8 mA 20 Hz Yes/No XSDC607319
PNP N.O.,N.C. 12-48 V 200 mA 50 Hz Yes/Yes XSDH607339
NPN N.O.,N.C. 12-48 V 200 mA 50 Hz Yes/Yes XSDJ607339
AC model, screw terminals
2 wire N.O./N.C. 24-240 V 500 mA 1.7 mA 10 Hz Yes/No XSDA600519
2 wire N.O./N.C. 43-132 V 500 mA 1.7 mA 10 Hz 3/Yes XSDA605539
AC and DC models, screw terminals
2 wire N.O./N.C. 24-240 Vac 500 mA 1.7 mA @ 120 V c
24-210 Vdc 100 mA 115 V 10 Hz 3/Yes XSDM600539
AC and AC/DC models, mini style receptacle, 3 pins
2 wire N.O./N.C. 24-240 V 500 mA 1.7 mA 10 Hz Yes/No XSDA600519R3
2 wire N.O./N.C. 93-132 V 500 mA 1.7 mA 10 Hz 3/Yes XSDA605539R3
2 wire N.O./N.C. 24-240 Vac 500 mA 1.7 mA
24-210 Vdc 100 mA 1.7 mA @ 120 V c10 Hz 3/Yes XSDM600539R3
Minimum Mounting Clearances (mm/inches)
XSD30-60 e: 300/12 e: not recommended
1/2" NPT
conduit ent.
4 x dia. 5.5 mm
4 x dia. .21" LED
3.90
100
1.5
40
2.56
65
2.56
65
.29
7.5
3.10
80
Dual Dimensions inches
mm
e
Side by side Face to face
e
Proximity Sensors
XSD Rectangular, Inductive Sensors
Long Range Block, AC and DC; Adjustable Sensing Range
283
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XSD Rectangular, Inductive Sensors / Long Rang e Block, AC and DC; Adjustable Sensing Range
Specifications
Ex: XSD605539 TTR3
aRefer to page 351 for target material correction coefficient Km.
Mechanical
Usable sensing range a24-48 mm (0.94" - 1.89")
Standard temperature range -13° F to +158° F (-25° C to +70° C)
Enclosure rating NEMA Type 3, 4, 6, 12, 13
IEC Type IP67
Vibration resistance 25 G, amplitude ± 2 mm, f = 10-55 Hz
Shock resistance 50 G for 11 ms
Standard target size (mild steel) 120 x 120mm (4.7" x 4.7")
Differential Max. 20%
Repeatability Max. 5%
Cable, PVC Screw terminals, #16 AWG
Electrical AC Models
DC Models AC/DC
Models
2 wire, N.O. 2 wire,
N.O./N.C. 4 wire
Voltage range (including ripple) 20-264 V 10-58 V 10-58 V 10-58 V 20-264 V
Voltage drop (across switch) 4.5 V 4 V 7 V 1.8 V 6 V
Inrush current (inductive @ 20mS) 2 A 2 A
Minimum load current 5 mA 1.5 V 5 mA
Current consumption (no load) 10 mA 10 mA
On delay (max.) 30 ms 5 ms 5 ms 10 ms 40 ms
Off delay (max.) 20 ms 40 ms 25 ms 10 ms 60 ms
Power-up delay (max.) 120 ms 75 ms 30 ms 10 ms 100 ms
Reverse polarity protection Standard Standard Standard
Radio Frequency Immunity (RFI) 4 cm (1.6") Minimum from antenna
Agency Listings E 164353 c
CCN NRKH
LR 44087 a
Class 3211 03 FM: J.I. OROH9.AX
(3610, 3611)
Options
Description Suffix
Extended temperature rangea
to +185° F (85° C) (a Not available on AC models with SCP) TT
to -40° F (-40° C) TF
Replacement modules
Description Catalog Number
DC 2 wire
Base receptacle, N.O. contact ZSDZ03
N.O. contact switch ZSDC607139
Base receptacle, N.O./N.C. ZSDZ02
N.O./N.C. contact switch ZSDC607319
DC 3 wire
Base receptacle ZSDZ02
PNP switch ZSDH607339
NPN switch ZSDJ607339
AC 2 wire
Base receptacle ZSDZ01
1 LED, N.O. SCP switch ZSDA600519
3 LED, SCP switch ZSDA605539
AC/DC ZSDM600539
For additional cable options and lengths see p. 518
Connector Cables (A or R3 suffix)
XSZCA901Y Mini Conn., 3 pin, 2 m, straight
XSZCA911Y Mini Conn., 3 pin, 2 m, 90°
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
13
2
3 wire DC, NO/NC
1
3
4 (NO)
+
-
PNP
2 (NC)
1
3
4 (NO)
+
-
NPN
2 (NC)
2 wire DC, non polarized
3
4
+/-
-/+
NO
3
4
+/-
-/+
2 wire AC, programmable
NO/NC
L1
7NO 8
7NC
load
8
L2
NC
®
Proximity Sensors
XSAV Tubular, Inductive Sensors
30mm Diameter, Motion Detection, DC or AC/DC
©1997- 2002 Schneider Electric All Rights Reserved
284 10/02
Proximity Sensors
XSAV Tubular, Inductive Sensors / 30 mm Diameter, Motion Detection, DC or AC/DC
The XSAV is a self-contained device used to detect and send output alarms for machinery
under speed or zero-speed conditions, as well as early jamming detection. The early detection
of the under speed condition is useful in reducing downtime due to jamming or transmission
failure. especially in the cases of medium and large motors.
The zero speed condition is used extensively for safety interlocking applications, including:
conveyors, pumps, mixers, centrifugal separators, elevators, saws, and crushers.
As long as the speed (number of pulses/min.) is above the threshold level – adjustable via 25
turn potentiometer within the threshold range – the output circuit assumes its closed state.
When the actual speed falls below the threshold level – the output circuit assumes its open
state. To preserve the start up delay, the switch should be reset by removing and reapplying
the power supply.
When the line voltage is initially applied, the output automatically assumes its closed state for
the duration of the start-up delay. This allows the mechanical assembly to overcome inertia and
reach its nominal speed, greatly simplifying the interlocking circuit. After the start-up delay, the
switch will perform as described above.
Care should be taken not to exceed the maximum frequency rating above which the sensor
cannot detect the target and therefore assumes “zero speed” condition.
Features:
Universal AC/DC versions
AC/DC models are PLC compatible
Linear speed threshold adjustment
Two adjustment ranges: 6 - 150 pulses/min. for zero-speed, 120 - 3,000 pulses/min.
for jamming detection
Built-in fixed power-up delay to overcome start-up inertia
Radio frequency immunity (RFI)
Reverse polarity protection on DC models
Noise and transient protection
Overload and short circuit protection (SCP) on DC models
LED indicators for switch in “closed” state
25-turn potentiometer provides fine adjustment of the under speed threshold
a(P) – PLC Compatible, (R) – Bleeder resistor required for PLC applications
qFor devices without SCP, see p. 298 for protective fuses.
Circuit
Type
Max.
Load
Residual
(Leakage)
Threshold
Range
(Pulse/Min.)
Max.
Frequency
(Pulse/Min.)
Start-up
Delay LED/SCP qCatalog
Number
30mm Diameter, 10mm sensing range, Shielded, 2m cable
DC models, 10-58 Vdc (including ripple)
PNP 200 mA 0 6-150 6000 9 sec. Yes/Yes XSAV11373
PNP 200 mA 0 6-150 6000 3 sec. Yes/Yes XSAV31373
PNP 200 mA 0 120-3000 48000 9 sec. Yes/Yes XSAV12373
PNP 200 mA 0 120-3000 48000 3 sec. Yes/Yes XSAV32373
AC/DC models, 20-264 Vac/dc
2 wires 0.35 A Vac/0.2 A Vdc 1.5 mA (P)a6-150 6000 9 sec. Yes/No XSAV11801
2 wires 0.35 A Vac/0.2 A Vdc 1.5 mA (P)a6-150 6000 0 sec. Yes/No XSAV01801
2 wires 0.35 A Vac/0.2 A D Vdc 1.5 mA (P)a120-3000 48000 9 sec. Yes/No XSAV12801
2 wires 0.35 A Vac/0.2 A Vdc 1.5 mA (P)a120-3000 48000 0 sec. Yes/No XSAV02801
Minimum Mounting Clearances (mm/inches)
30 mm e: 20/.79 e: 120/4.7 e: 30/1.2 D: 30/1.2, H: 0/0
2.24
57
.94
24
Adjustment
potentiometer
M 30 x 1.5
Dual Dimensions inches
mm
Sid
e
b
y s
id
e
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
Proximity Sensors
XSAV Tubular, Inductive Sensors
30mm Diameter, Motion Detection, DC or AC/DC
285
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XSAV Tubular, Inductive Sensors / 30 mm Diameter, Motion Detection, DC or AC/DC
Specifications
1/Fr in the start up delay formula is the actual preset frequency adjusted via potentiometer. (1/Fr is not significant if threshold is above
60 pulses/min.).
aRefer to page 351 for target material correction coefficient Km.
Ex: XSAV11373 TT L05
Mechanical
Usable sensing rangea0.7" (18 mm) 0-0.15" (0-4 mm)
1.18" (30 mm) 0--.31" (0-8 mm)
Standard temperature range -13° F to +158° C (-25° F to +70° F)
Enclosure rating NEMA Type 1, 3, 4, 6, 12, 13
IEC Type IP67
Vibration resistance 25 G, amplitude ± 2 mm, f =10-55 Hz
Shock resistance 50 G duration 11 ms
Standard target size (steel) 0.7" (18mm) diameter 0.7" x 0.7" (18mm x 18mm)
1.18" (30mm) diameter 1.18" x 1.18" (30mm x 30mm)
Repeatability (% of Sr) 3%
Differential (hysteresis) 5-15% of pre-set frequency
Cable PvR 20 AWG
Electrical AC/DC DC
Voltage drop (across switch) max. 5.7 V 1.8 Vdc
Inrush current (inductive @ 20 ms) 2 A
Minimum load current 5 mA
Current Consumption (no load) 15 mA
Start-up delay (max.)
XSAV1 models 9 sec. ±20% + 1/Fr
XSAV3 models 3 sec. ±20% + 1/Fr
XSAV0 models 0 sec.
Agency Listings
Options
Description Suffix
Extended temperature range
(only one option per device)
to +185° F (+85° C) TT
to -40° F (-40° C) TF
5 meter cable length L05
10 meter cable length L10
Accessories
Description Catalog Number
Metal locknuts (1 pair included) XSZE130
Mounting bracket, 90° steel 9006PA30
Mounting bracket, plastic XSZB130
0.5" NPT conduit adapter 7427
Application Notes:
The number of targets is determined knowing that the actual number of pulses per minute n, is n=mN where m is the number of targets
and N the speed in rpm.
This number (n) should be within the operating frequency range given in the selection table. For reasons of mechanical balance,
even numbers are recommended (2, 4, 6 etc.).
Frequency threshold adjustment:
As long as the speed (number of pulses/min.) is above the threshold level – adjustable via 25 turn potentiometer within the threshold range
– the output circuit assumes its closed state. When the actual speed falls below the threshold level, the output circuit assumes its open
state. To preserve the start-up delay, the switch should be reset by removing and reapplying the power supply.
When the line voltage is initially applied, the output automatically assumes its closed state for the duration of the start-up delay. This allows
the mechanical assembly to overcome inertia and reach its nominal speed, greatly simplifying the interlocking circuit. After the start-up
delay, the switch will perform as described above.
Care should be taken not to exceed the maximum frequency rating above which the sensor cannot detect the target, therefore, assuming
zero speed condition.
XSZB130
9006PA30
7427
A
ccessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298
Wiring
3 wire, DC
+
-
PNP Bk
Bn
Bu
Bn
Bu
2 wire, AC/DC
+/-
+/-
Cover
25 turn
Potentiometer
Proximity Sensors
XS Tubular Inductive Sensors
Weld Field Immune, DC
©1997- 2002 Schneider Electric All Rights Reserved
286 10/02
Proximity Sensors
XS Tubular Inductive Sensors / Weld Field Immune, DC
Features
Industrial welding processes create fields of electromagnetic “noise” which can interfere with
the magnetic fields of inductive proximity sensors. Standard proximity sensors can be falsely
triggered when near to these fields. WFI sensors allow uninterrupted performance when
placed extremely close to the conductor carrying the welding current.
The body styles are cylindrical in 0.47", 0.7" and 1.18" (12, 18 and 30 mm) diameters.
Enclosure material is brass coated in Teflon® to prevent slag (molten bits of metal) from
sticking to sensing face, reducing the possibility of false triggering.
Available in Micro connector versions.a
Mounting nuts included.
aSee p. 518 for matching connector cables.
The formula below shows the relationship between distance (r [mm]) and electromagnetic flux
density (B[MT]).
Circuit
Type
Output
Mode
Voltage
Range
Voltag e Drop
Maximum
Load Current
Maximum
Operating Frequency
Maximum
Catalog
Number
12 mm Shielded, DC with Micro Connector a, Nominal Sensing Distance–2 mm
PNP N.O. 10 to 36 Vdc 2.5 V 250 mA 1000 Hz XS1M12PAW01D
12 mm Non-shielded, DC with Micro Connector a, Nominal Sensing Distance–4 mm
PNP N.O. 10 to 36 Vdc 2.5 V 250 mA 1000 Hz XS2M12PAW01D
18 mm Shielded, DC with Micro Connector a, Nominal Sensing Distance–5 mm
PNP N.O. 10 to 36 Vdc 2.5 V 250 mA 500 Hz XS1M18PAW01D
30 mm Shielded, DC with Micro Connector a, Nominal Sensing Distance–10 mm
PNP N.O. 10 to 36 Vdc 2.5 V 250 mA 250 Hz XS1M30PAW01D
B [mT] = 0.2xI [A] B [mT] =
I[A] =
r [mm] =
Electromagnetic Flux Density
Welding Current
Distance
r [mm]
Minimum Mounting Clearances
Side by Side Face to Face Facing a Metal Object Mounted in Metal
eee dh
IN mm IN mm IN mm IN mm IN mm
XS1M12 0 0 0.27 7 0.24 6 0.47 12 0 0
XS2M12 0.59 15 0.27 7 0.43 11 1.42 36 0.31 8
XS1M18 0 0 0.63 16 0.35 9 0.71 18 0 0
XS1M300 00.79200.7920 1.183000
LED
LED
LED
LED
c
b
a
a = Overall Length (mm)
b = Threaded Section (mm)
c = for Non-shielded Sensors (mm)
abc
XS1M12 2.3" (60) 1.6" (40) 0
XS2M12 2.3" (60) 1.5" (38) 0.16" (4)
XS1M18 2.3" (60) 1.6" (40) 0
XS1M30 2.3" (60) 1.6" (40) 0
XS1M18 XS1M30
XS1M12 XS2M12
Dimensions
Side by side
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
D
H
Proximity Sensors
XS Tubular Inductive Sensors
Weld Field Immune, DC
287
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Tubular Inductive Sensors / Weld Field Immune, DC
Specifications
aRefer to page 351 for target material correction coefficient Km.
Accessories
Mechanical XS1M12 XS2M12 XS1M18 XS1M30
Usable Sensing Range a1.6 mm 3.2 mm 4 mm 8 mm
Temperature Range 13° F to +158° F (-25° C to +70° C)
Enclosure Rating NEMA Type 3, 4, 6, 12, 13, 4X Indoor
IEC Type IP67 (or depending on connector)
Tightening torque (max.) 15 N•m 11.1 (lb-ft) 15 N•m 11.1 (lb-ft) 35 N•m 26 (lb-ft) 50 N•m 37 (lb-ft)
Vibration 25 G Amplitude +/-2 mm f = 10-55 Hz
Shock Resistance 50 G for 11 ms
Differential (% of Sr) 20%
Repeatability (% of Sr) 3%
LED Indicator Type 4 LED windows at 90 degrees
Enclosure Material Brass with Teflon coating
Electrical
Voltage Range 12 to 24 Vdc
Voltage Limit (Including Ripple) 10 to 36 Vdc
Current Consumption (max.) (No Load) 15 mA
max. Leakage (Residual) Current–Open State
Power-up Delay (max.) 10 ms 10 ms 10 ms 10 ms
On Delay (Maximum) 0.1 ms 0.2 ms 0.2 ms 0.7 ms
Off Delay (max.) 0.4 ms 0.4 ms 0.6 ms 5 ms
Protective Circuitry
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
Agency Listings E 164869
CCN NRKH
LR 702985
Class 3211 03
Description For Sensor Diameter Catalog Number
Mounting Brackets
0.47" (12 mm) XSZB112
0.47" (12 mm) 9006PA12
0.7" (18 mm) XSZB118
0.7" (18 mm) 9006PA18
1.18" (30 mm) XSZB130
1.18" (30 mm) 9006PA30
Mounting Nuts
0.47" (12 mm) XSZE112
0.7" (18 mm) XSZE118
1.18" (30 mm) XSZE130
XSZB1
9006PA
XSZE
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Wiring
BN/1
BU/3
BK/4 N.O.
PNP
+
14
23
®
Proximity Sensors
XS Rectangular, Inductive Sensors
Weld Field Immune, AC and DC
©1997- 2002 Schneider Electric All Rights Reserved
288 10/02
Proximity Sensors
XS Rectangular, Inductive Sensors / Weld Field Immune, AC and DC
Features:
Compact rectangular inductive proximity sensors for demanding applications including welding
and machine tools.
Housings - XSB: Plastic (thermoplastic polyester) kXSE: Plastic (fiber glass
reinforced polyamide); screw terminal models can be offered also in slag resistant
thermoset plastic
XSE models can be flush mounted in metal • Plug-in version for XSB k Screw terminals,
PVC cable, mini style receptacle connections depending on the model k Weld Field
Immunity (WFI) on most models k Radio Frequency Immunity (RFI)
Noise and transient protection k Reverse polarity protection (DC models) k Selected models
are offered with short circuit protection (SCP) and overload protection kUL Recognized
and CSA Certified kFactory Mutual approved for non- incendive application, NAMUR
sensors approved for intrinsically safe applications.
tFor side sensing, change last numeric digit as follows; Front: 1; Right: 3; Left: 4. Ex: XSB A105114C for left sensing.
PLC Applications:
R = Bleeder resistor needed.
P = PLC compatible.
aFor devices without SCP, see p. 298 for protective fuses.
Output
Mode/
Sensing
Face (XSE)
Voltage
Range
Max.
Load
Current
Residual
(leakage)
Current
Operating
Frequency Housing LED/SCPa/
WFI
Catalog
Number
XSB 13mm (.511") sensing range, Non-shielded
AC, 2 wire, plug-in, screw terminals, end sensing
N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112
N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212
AC, 2 wire, plug-in, mini style connector, end sensing
N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112A
N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212A
AC, 2 wire, non plug-in, 2m(6’) cable, end sensing t
N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112C
N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212C
AC, 2 wire, non plug-in, mini style connector, end sensing t
N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112R
N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212R
DC, 2 wire, plug-in, not WFI
N.O. 12-48 V 80 mA 1.2 mA 250 Hz Polyester No/No/No XSBC10710
XSE 10mm (.393") sensing range, Shielded, DC models, 2 wire, N.O.
2m(6) cable
End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071300
Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071330
Screw terminals
End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC107130
Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC107133
Sealed cable (.8m - 2.6’), with pig-tailed mini style connector
End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071302
Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071332
End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1072301
Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1072331
Sealed cable (.8m - 2.6’), with pig-tailed micro style connector
End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071301
Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071331
2xO4.2
.16" dia.
.78
20
1.31
33.5
1.30
33
3.01
76.5
Back
view
.63
16
1/2" NPT
conduit ent.
==
2.36
60
L=2 m
LED
1.02
26
1.95
49.5
.78
20
Side b
End a
.49
12.5
.98
25
2xO4.2
1.02
26
.16" dia.
XSB
XSE
Dual Dimensions inches
mm
NotforUseon
NewApplications
(XSBOnly)
LimitedProductAvailability
Proximity Sensors
XS Rectangular, Inductive Sensors
Weld Field Immune, AC and DC
289
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Rectangular, INductive Sensors / Weld Field Immune, AC and DC
Specifications
tRefer to p. 351 for target material correction coefficient Km.
Mechanical
Usable sensing range t0-9 mm (.35") for XSB
0-8 mm (.31’) for XSE
Standard temperature range -13° F to +158° F (-25° C to +70° C)
Enclosure rating NEMA Type 3, 4, 6, 12, 13
IEC Type IP67
Vibration resistance 25 G, amplitude ± 2 mm, f =10-55 Hz
Shock resistance 50 G for 11 ms
Standard target size (steel) 40 x 40 mm (1.6" x 1.6") for XSB
30 x 30 mm (1.18" x 1.18") for XSE
Differential Max. 20%
Repeatability Max. 5%
Radio Frequency Immunity (RFI) Standard
Cable Screw terminals, #16 AWG
PvR, #20 AWG
Electrical AC Models DC Models
XSB XSE
Voltage drop (across switch) 9.5 V 7 V 4 V
Inrush current (inductive @ 20 mS) 0.9 A
Minimum load current 30 mA 1.5 mA 1.5 mA
On delay (max.) 40 ms .4 ms 12 ms
Off delay (max.) 30 ms 1 ms 3 ms
Power-up delay (max.) 80 ms 1.2 ms 16 ms
Reverse polarity protection Standard Standard
Weld field immunity 100 mT
Agency Listings E 164353 c
CCN NRKH
LR 44087
Class 3211 03 FM: J.I. OROH9.AX
(3610, 3611)
Options
Description Suffix
Extended temperature range
to +185° F(+85° C) TT
to -40° F(-40° C) TF
5 meter (16') cable length L05
Accessories
XSE mounting brackets Catalog Number
Flat XSEZ01
90° XSEZ02
Plug-in models - replacement modules, AC models
Base receptacle AC ZSBZ11
AC, N.O. Plug in switch ZSBA105112
AC, N.C. Plug in switch ZSBA105212
Base receptacle DC ZSBZ12
DC, N.O. Plug in switch ZSBC10710
Minimum Mounting Clearances (mm/inches)
XSE.15 e: 38/1.5" e: 97/3.8"
XSB.20 e: 80/3.1" e: 160/6.3"
For additional cable options and lengths see p. 518
Connector Cables (A or R3 suffix)
XSZCA901Y Mini Conn., 3 pin, 2 m, straight
XSZCA911Y Mini Conn., 3 pin, 2 m, 90°
Wiring
Connector Cable
Blue BU –
Brown BN +
Black BK Output
13
2
2 wire AC
3
4
NO
1
2
NC
L1
L2
L1
L2
2 wire DC
1
4
NO
+
-
XSE 2 wire type DC
BN/3
BU/4
NO
+/-
-/+
®
e
Side by side Face to face
e
Proximity Sensors
Inductive Sensors; NAMUR, 2 Wire DC
For use with an intrinsically safe barrier relay when used in hazardous locations
©1997- 2002 Schneider Electric All Rights Reserved
290 10/02
Proximity Sensors
0
Inductive Sensors; NAMUR, 2 Wire DC / For use with an intrinsically safe barrier relay when used in hazardous locations
Cylindrical type
Plastic block type
Applications
Intrinsically safe applications (hazardous area).
When used in these applications, it is imperative that (NAMUR) sensors be used only with an
NY2 intrinsically safe relay/amplifier, or a suitably approved, compatible solid state system.
Example: Painting line in car assembly plant.
tRefer to page 351 for target material correction coefficient Km.
Barrel
Diameter
Barrel
Type
Nominal
Sensing
Distance t
Operating
Zone
Operating
Frequency
Catalog
Number
Nickel plated brass case
Shielded, 2 m (6.6’) cable
4 mm smooth 0.03" (0.8 mm) 0-0.02" (0-0.6 mm) 1500 Hz XSLN08122
5 mm threaded 0.03" (0.8 mm) 0-0.02" (0-0.6 mm) 1500 Hz XSMN08122
6.5 mm smooth 0.04" (1 mm) 0-0.03" (0-0.8 mm) 1500 Hz XSLN01122
8 mm threaded 0.06" (1.5 mm) 0-0.03" (0-0.8 mm) 1500 Hz XSAN01122
Plastic case
Shielded, 2 m (6.6’) cable
8 mm threaded 0.06" (1.5 mm) 0-0.05" (0-1.2 mm) 1000 Hz XSPN01122
12 mm threaded 0.08" (2 mm) 0-0.06" (0-1.6 mm) 800 Hz XSPN02122
18 mm threaded 0.2" (5 mm)( 0-0.16" (0-4.0 mm) 500 Hz XSPN05122
30 mm threaded 0.4" (10 mm) 0-0.31" (0-8.0 mm) 300 Hz XSPN10122
Non-shielded, 2m (6.6’) cable
12 mm threaded 0.16" (4 mm) 0-0.12" (0- 3.2 mm) 400 Hz XSPN04122
18 mm threaded 0.31" (8 mm) 0-0.25" (0- 6.4 mm) 300 Hz XSPN08122
30 mm threaded 0.6" (15 mm) 0-0.47" (0-12.0 mm) 200 Hz XSPN15122
Enclosure
Style
Nominal
Sensing
Distance t
Operating
Zone
Operating
Frequency
Catalog
Number
Shielded, terminal connections
Limit switch style 0.6" (15 mm) 0-0.47" (0-12.0 mm) 100 Hz XSCN151229
Non-shielded, terminal connections
Compact rectangular 0.5" (13 mm) 0-0.35" (0- 9.0 mm) 250 Hz XSBN10122
Block style 1.0" (25 mm) 0-0.8" (0-20.0 mm) 250 Hz XSBN25122
Block style - extended range 1.6" (40 mm) 0-1.25" (0-32.0 mm) 25 Hz XSDN501229
4
3
2
1.65
1
Sn Distance
(mm)
current I (mA)
Principle of operation
2 wire NAMUR proximity sensors
are characterized by the fact that
their current consumption is
changed by the presence of a
metal object within the sensing
zone.
They differ from a standard
sensor by the absence of an
output circuit. All the processing
is carried out by the associated
amplifier or solid state system to
which it is connected.
The mode of operation is
analogous to an N.C. contact:
no object present: sensor
is in the conducting state
object present: sensor is in
the non-conducting state
Factory Mutual System
Approved for Div I, II hazardous
location with NY2 safe barrier
relay.
Proximity
switch
Proximity Sensors
Inductive Sensors; NAMUR, 2 Wire DC
For use with an intrinsically safe barrier relay when used in hazardous locations
291
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Inductive Sensors; NAMUR, 2 Wire DC / For use with and intrinsically safe barrier relay when used in hazardous locations
Specifications
tConsider for intrinsically safe systems.
Mechanical
Standard temperature range operation -25° C to +70° C (-13° F to +158° F)
storage -40° C to +80° C (-40° F to +176° F)
Enclosure rating
NEMA Type 4mm & 5mm 1, 3, 4, 13
all others 3, 4, 6, 12, 13
IEC Type 4mm & 5mm IP64
all others IP67
Repeatability (% of Sr) 5% or less
Cable 2 wire 22 AWG (0.11 mm2), PvR
Electrical
Voltage range 7 to 12 Vdc
Current consumption from supply Sensor activated (target present) = 1 mA or less;
8.2 V (internal resistance: about 1 K)Sensor not activated (target absent) = 3 mA or more;
Switching point defined for usable sensing distance
and standard metal target: 1.65 mA
Maximum line resistance Between sensor and amplifier: 50 ohms
Apparent sensing capacitance t280 nF maximum
Apparent sensing inductance t220 micro H maximum
Agency Listings LR 15996
Class 3218 06 FM: J.I. OROH9.AX
(3610, 3611)
NAMUR Sensors
DC 2 wire, N.C.
M: Metal case - P: Plastic case.
4mm unthreaded
Metal
M5x0.5
Metal
6.5mm unthreaded
Metal
M8x1
Metal
M8x1
Plastic
M12x1
Plastic
M18x1
Plastic
XSLN08122 XSMN08122 XSLN01122 XSAN01122 XSPN01122 XSPN02122 XSPN05122
M30x1.5
Plastic
Dimensions
page 292
Plastic
Sensors not suitable for flush mounting in metal
M12x1
Plastic
M18x1
Plastic
M30x1.5
Plastic
Dimensions
page 288
Plastic
Dimensions
page 272
Plastic
Dimensions
page 280
Plastic
XSPN10122 XSCN151229 XSPN04122 XSPN08122 XSPN15122 XSBN10122 XSBN25122 XSDN501229
1.18
30
1.18
30
1.57
40
1.04
26.5
1.04
26.5
1.45
37
1.71
43.5
1.65
42
1.45
37
1.71
43.5
1.71
43.5
connected to a solid state input (e.g.: TSX PLC input card, TSX DET 466)
_
+
BU-2
BN-1 Ri = 1K
I > 3mA
7 to 12 Vdc
BU-2
BN-1 Ri = 1K
I < 1mA
7 to 12 Vdc
Object
present
Object
absent
+
+
-
-
+
+
-
-
Non-intrinsically safe applications (normal safe zone). Association with an NY2 power supply/relay amplifier unit
+_
BN BU
42.
F1.
+
12(110 to 240V AC, P=5VA, 50 Hz).
NY2
proximity
sensor
}
Wiring diagram
2.
0Dual Dimensions inches
mm
Proximity Sensors
XS Inductive Sensors
Analog Output, DC
©1997- 2002 Schneider Electric All Rights Reserved
292 10/02
Proximity Sensors
XS Inductive Sensors / Analog Output, DC
Features:
DC output current is directly proportional to the target distance
Three body styles: tubular, limit switch style (with 5 position turret head), block style
Both metal and plastic enclosures available
Two types of output:
3 wire: 0 - 10 mA, 0 - 16 mA
2 wire: 4 - 20 mA, 4 - 14 mA
Nominal
Sensing
Distance
Enclosure
Style
Enclosure
Material
Voltage
Range
Max.
Circuit
Type
Output
Current
Operating
Frequency
Max.
Catalog
Number
12 mm Diameter - 2 meter cable
0.2 - 2 mm Shielded Metal 24 Vdc 2 wire 4 - 20 mA 1500 Hz XS1M12AB120
3 wire 0 - 16 mA
0.4 - 4 mm Non-Shielded Plastic 24 Vdc 2 wire 4 - 20 mA 1500 Hz XS4P12AB120
3 wire 0 - 16 mA
0.4 - 4 mm Non-Shielded Plastic 24-48 Vdc 2 wire 4 - 14 mA 1500 Hz XS4P12AB110
3 wire 0 - 10 mA
18 mm Diameter - 2 meter cable
0.5 - 5 mm Shielded Metal 24 Vdc 2 wire 4 - 20 mA 500 Hz XS1M18AB120
3 wire 0 - 16 mA
0.8 - 8 mm Non-Shielded Plastic 24 Vdc 2 wire 4 - 20 mA 500 Hz XS4P18AB120
3 wire 0 - 16 mA
0.8 - 8 mm Non-Shielded Plastic 24-48 Vdc 2 wire 4 - 14 mA 500 Hz XS4P18AB110
3 wire 0 - 10 mA
30 mm Diameter - 2 meter cable
1 - 10 mm Shielded Metal 24 Vdc 2 wire 4 - 20 mA 300 Hz XS1M30AB120
3 wire 0 - 16 mA
1.5 - 15 mm Non-Shielded Plastic 24 Vdc 2 wire 4 - 20 mA 300 Hz XS4P30AB120
3 wire 0 - 16 mA
1.5 - 15 mm Non-Shielded Plastic 24-48 Vdc 2 wire 4 - 14 mA 300 Hz XS4P30AB110
3 wire 0 - 10 mA
Limit Switch Style - 2 meter cable
2 - 20 mm Non-Shielded Plastic 24-48 Vdc 2 wire 4 - 14 mA 60 Hz XSCH207629
3 wire 0 - 10 mA
2 - 20 mm Non-Shielded Plastic 24 Vdc 2 wire 4 - 20 mA 60 Hz XSCH203629
3 wire 0 - 16 mA
Block Style - 2 meter cable
6 - 60 mm Non-Shielded Plastic 24-48 Vdc 2 wire 4 - 14 mA 50 Hz XSDH607629
3 wire 0 - 10 mA
6 - 60 mm Non-Shielded Plastic 24 Vdc 2 wire 4 - 20 mA 50 Hz XSDH603629
3 wire 0 - 16 mA
Minimum Mounting Clearances (mm/inches)
Side by side Face to face Facing a metal object Mounted in metal
12 mm Shielded e: 4 mm (0.16") e: 24 mm (0.94") e: 6 mm (0.24") d: 12 mm (0.47") h: 0 mm (0")
12 mm Non-shielded, 24 V e: 16 mm (0.63") e: 48 mm (1.89") e: 12 mm (0.47") d: 36 mm (1.42") h: 8 mm (0.31")
12 mm Non-shielded, 48 V e: 16 mm (0.63") e: 48 mm (1.89") e: 12 mm (0.47") d: 36 mm (1.42") h: 8 mm (0.31")
18 mm Shielded e: 10 mm (0.39") e: 60 mm (2.36") e: 15 mm (0.59") d: 18 mm (0.71") h: 0 mm (0")
18 mm Non-shielded, 24 V e: 32 mm (1.26") e: 96 mm (3.78") e: 24 mm (0.94") d: 54 mm (2.12") h: 16 mm (0.63")
18 mm Non-shielded, 48 V e: 32 mm (1.26") e: 96 mm (3.78") e: 24 mm (0.94") d: 54 mm (2.12") h: 16 mm (0.63")
30 mm Shielded e: 20 mm (0.79") e: 120 mm (4.72") e: 30 mm (1.18") d: 30 mm (1.18") h: 0 mm (0")
30 mm Non-shielded, 24 V e: 60 mm (2.36") e: 180 mm (7.08") e: 45 mm (1.77") d: 90 mm (3.54") h: 30 mm (1.18")
30 mm Non-shielded, 48 V e: 60 mm (2.36") e: 180 mm (7.08") e: 45 mm (1.77") d: 90 mm (3.54") h: 30 mm (1.18")
Limit switch style e: 80 mm (3.15") e: 160 mm (6.30")
Block style e: 300 mm (11.81") not recommended
c
b
a
Dimensions:
a = overall length (mm)
b = threaded section (mm)
c = for non-shielded sensors (mm)
1/2" NPT
conduit ent.
1.57
40
1.57
40
4.5
114.5
LED
1.
1
28
2.36
60
1.18
30
2 x .2" dia.
1.77
45
2 x 5.3mm dia.
1/2" NPT
conduit ent.
4 x dia. 5.5 mm
4 x dia. .21" LED
3.90
100
1.5
40
2.56
65
2.56
65
.29
7.5
3.10
80
XSD
Dual Dimensions inches
mm
thread
M12x1
M18x1
M30x1
XSC
Tubular Style dimensions (mm)
abc
12 mm Metal 1.9" (50) 1.6" (42) 0
Plastic 1.9" (50) 1.6" (42) 0
18 mm Metal 1.9" (50) 1.6" (42) 0
Plastic 1.6" (40.6) 1.0" (26) 8
30 mm Metal 1.9" (50) 1.6" (42) 0
Plastic 2.07" (52.6) 1.2" (32) 0.5" (13)
Sid
e
b
y s
id
e
e
Face to face
e
Facing a metal object
e
Mounting in a metal support
d
h
e
Side by side Face to face
e
e
Side by side Face to face
e
Proximity Sensors
XS Inductive Sensors
Analog Output, DC
293
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductive Sensors / Analog Output, DC
Specifications
Mechanical
Temperature range -13° F to +158° F (-25° C to +70° C)
Enclosure rating IEC Type IP67
Tightening torque (max.)
Metal Plastic
12mm 6 N•m 4.5 (lb-ft) 2 N•m 1.5 (lb-ft)
18mm 15 N•m 11.1 (lb-ft) 5 N•m 3.7 (lb-ft)
30mm 40 N•m 29.5 (lb-ft) 20 N•m 14.7 (lb-ft)
Enclosure material Metal
Plastic
Wiring Tubular 22 AWG (0.34 mm2), PvR
Limit Switch/Block style Screw term. 16 AWG(1.5 mm2)
General Characteristics
Voltage limit (including ripple)
XS1kkkk120, XS4kkkk120: 15 - 38 Vdc
XS1kkk110, XS4kkk110: 15 - 58 Vdc
XSCH207kkk, XSDH607kkk: 19 - 58 Vdc
XSCH203kkk, XSDH603kkk: 19 - 30 Vdc
Current consumption (no load) 4 mA
Max. Output current drift with the rated operating temperature 10%
Power Supply Current (no load) 4 mA
Repeat Accuracy + - 1%
Linearity error + - 4%
Protective Circuitry
Short circuit protection yes
Overload protection yes
Reverse polarity protection yes
Agency Listings (XS1, XS4) E 164869 CCN NRKH
(XSC, XSD) E 164353 CCN NKCR
LR 44087
Class 3211 03
Output Curves 4 to 20 mA, 2 wire connection (cylindrical models)
XSCH20k629 XS1M12AB120 XS1M18AB120 XS1M30AB120
XSDH20k629 XS4P12AB120 XS4P18AB120 XS4P30AB120
Output Curves 0 to 10 mA, 3-wire connection, (cylindrical models)
XS4P12AB110 XS4M18AB110 XS4P30AB110
Output current Value of R (R = load
impedance)
24 V 0 to 10 mA 1800
0 to 16 mA 1125
48 V 0 to 10 mA 4200
Ensure a minimum of 5 V between the + and
sensor output
W
iring
+
BN/1
BK/4
BU/3
mA
R
Is
Output Current
2-wire
+
BN/1
BK/4
BU/3
mA
R
IsOutput Voltage
3-wire
U=R Is
®
22
Sn = 0.2...2 mm Ø 12 mm
20
18
16
14
12
10
8
6
4
2
0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2
Sensing distance/object (mm)
Output current Is (mA)
22
Sn = 0.5...5 mm Ø 18 mm
20
18
16
14
12
10
8
6
4
2
0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Sensing distance/object (mm)
Output current Is (mA)
22
Sn = 1....10 mm Ø 30 mm
20
18
16
14
12
10
8
6
4
2
0
0 1 2 3 4 5 6 7 8 9 10
Sensing distance/object (mm)
Output current Is (mA)
Sn = 20 mm
1 XSCH203629 2 XSCH207629
1
2
Sensing distance/object (mm)
Output current Is (mA)
20
16
12
8
4
0
0 3 6 9 12 15 18 21 24 27
22
Sn = 1.5...15 mm Ø 30 mm
20
18
16
14
12
10
8
6
4
2
0
0 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15
Sensing distance/object (mm)
Output current Is (mA)
22
Sn = 0.8...8 mm Ø 18 mm
20
18
16
14
12
10
8
6
4
2
0
0 0.8 1.6 2.4 3.2 4 4.8 5.6 6.1 7.2 8
Sensing distance/object (mm)
Output current Is (mA)
22
Sn = 0.4...4 mm Ø 12 mm
20
18
16
14
12
10
8
6
4
2
0
0 0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4
Sensing distance/object (mm)
Output current Is (mA)
Sn = 6 0 mm
1 XSDH603629 2 XSDH607629
1
2
Sensing distance/object (mm)
Output current Is (mA)
20
16
12
8
4
0
0 10 20 30 40 50 60 70
11
Sn = 0.4...4 mm Ø 12 mm
10
9
8
7
6
5
4
3
2
1
0
0 0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4
Sensing distance/object (mm)
Output current Is (mA)
11
Sn = 0.8...8 mm Ø 18 mm
10
9
8
7
6
5
4
3
2
1
0
0 0.8 1.6 2.4 3.2 4 4.8 5.6 6.4 7.2 8
Sensing distance/object (mm)
Output current Is (mA)
11
Sn = 1.5...15 mm Ø 30 mm
10
9
8
7
6
5
4
3
2
1
0
0 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15
Sensing distance/object (mm)
Output current Is (mA)
Proximity Sensors
XT Capacitive Sensors
12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC
©1997- 2002 Schneider Electric All Rights Reserved
294 10/02
Proximity Sensors
XT Capaciti ve Sensors / 12 mm 18 mm, 30 mm and Limit Switch Sty le; AC and DC
Features
Capacitive proximity sensors are ideal for sensing non-metal objects or for level control of fluids
and granular material. A special wall mounting bracket has been designed to replace thick or
metal walls the sensor is not capable of penetrating. The actual sensing range varies widely
depending on the target material and environmental conditions (humidity, dust, etc.).
An internal compensation electrode is incorporated to suppress the effects of material deposits
on the sensor’s face. The threshold level is adjustable via a 20 turn potentiometer (except
12mm) located at the rear of the switch. This adjustment can be used to zero out the presence
of a plastic tube allowing the switch to sense ”through” a bulk material or liquid level.
Other features include: metal housing: nickel plated brass, plastic housing: PBT; can be flush
mounted in metal (except XT4); LED indication for output in closed state; mounting nuts
included for threaded models; mounting bracket included for non-threaded versions, well
mounting brackets are optional; sensitivity adjustment tool included; UL & CSA; CE mark.
Sensitivity Adjustment
Nominal Sensing
Distance
AC or
DC Output Mode Circuit
Type Voltage Range Operating
Frequency Catalog Number
12 mm diameter, 2m (6.6’) cable, Non Adjustment
Flush Mountable -- Threaded Metal Case
2 mm DC N.O. PNP 12 – 24 V 100 Hz XT1M12PA372
2 mm DC N.C. PNP 12 – 24 V 100 Hz XT1M12PB372
2 mm DC N.O. NPN 12 – 24 V 100 Hz XT1M12NA372
18 mm diameter, 2m (6.6’) cable, with Sensitivity Adjustment
Flush Mountable -- Threaded Metal Case
5 mm AC N.O. 2 wire 24 – 240 V 25 Hz XT1M18FA262
5 mm AC N.C. 2 wire 24 – 240 V 25 Hz XT1M18FB262
5 mm DC N.O. PNP 12 – 24V 100 Hz XT1M18PA372
5 mm DC N.C. PNP 12 – 24V 100 Hz XT1M18PB372
5 mm DC N.O. NPN 12 – 24V 100 Hz XT1M18NA372
Non-Flush Mountable -- Threaded Plastic Case
8 mm AC N.O. 2 wire 24 – 240 V 25 Hz XT4P18FA262
8 mm DC N.O. PNP 12 – 24V 100 Hz XT4P18PA372
8 mm DC N.O. NPN 12 – 24V 100 Hz XT4P18NA372
30 mm diameter, 2m (6.6’) cable, with Sensitivity Adjustment
Flush Mountable -- Threaded Metal Case
10 mm AC N.O. 2 wire 24 – 240 V 25 Hz XT1M30FA262
10 mm AC N.C. 2 wire 24 – 240 V 25 Hz XT1M30FB262
10 mm DC N.O. PNP 12 – 24V 100 Hz XT1M30PA372
10 mm DC N.C. PNP 12 – 24V 100 Hz XT1M30PB372
10 mm DC N.O. NPN 12 – 24V 100 Hz XT1M30NA372
Non-Flush Mountable -- Threaded Plastic Case
15 mm AC N.O. 2 wire 24 – 240 V 25 Hz XT4P30FA262
15 mm AC N.C. 2 wire 24 – 240 V 25 Hz XT4P30FB262
15 mm DC N.O. PNP 12 – 24V 100 Hz XT4P30PA372
15 mm DC N.O. NPN 12 – 24V 100 Hz XT4P30NA372
32 mm diameter, 2m (6.6’) cable, with Sensitivity Adjustment
Flush Mountable -- Smooth Plastic Case
15 mm AC N.O. 2 wire 110 – 220 V 10 Hz XT1L32FA262
15 mm AC N.C. 2 wire 110 – 220 V 10 Hz XT1L32FB262
Non-Flush Mountable -- Smooth Plastic Case
20 mm AC N.O. 2 wire 110 – 220 V 10 Hz XT4L32FA262
20 mm AC N.C. 2 wire 110 – 220 V 10 Hz XT4L32FB262
Limit Switch Style, 0.5" NPT, with Sensitivity Adjustment
Flush Mountable -- Plastic Case
15 mm AC N.O. or N.C. 2 wire 24 – 240 V 25 Hz XT7C40FP262
15 mm DC N.O. / N.C. PNP 12 – 24V 100 Hz XT7C40PC440
15 mm DC N.O. / N.C. NPN 12 – 24V 100 Hz XT7C40NC440
Front face
Contamination
(a)
(b)
Main electrode
Earth electrode
Compensation electrode
(a) : compensation field (suppression
of external contamination)
(b) : main electric field
XS7 Limit
Switch Style
XT1/4 Smooth
XT1/4 Threaded
Level Detection
Well Bracket
XTAZ
thread
M30x1.5
thread
M18x1
thread
M12x1
12
1 Sensitivity adjustment potentiometer and output
state indicator ( yellow LED )
2 Adjustment using screwdriver
Proximity Sensors
XT Capacitive Sensors
12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC
295
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XT Capac itive Sensors / 12 mm, 18 mm , 30 mm, 32 mm and Limit Switch S tyle; AC and D C
Specifications
tMaximum load current 150mA when Ue=220V.
The operating distance of the sensor is related to the dielectric constant (εϒ) of the object material
to be detected. The higher the value of εϒ, the easier it will be for the object to be detected.
NOTE: This product should not be used in an environment with dew or condensation
The Usable Sensing Distance depends on the object material: Su = Sn x Fc
Su = Usable Sensing Distance; Sn = Nominal Sensing Distance; Fc = Correction Coefficient for the object material
Example: Sensor XT1M30PA372 used to detect a rubber object Sn = 10 mm, Fc = 0.3
Usable Sensing Distance Su = 10 mm x 0.3 = 3 mm
Accessories
Mechanical
Standard Temperature Range -13° F to +158° F (-25° C to +70° C)
Enclosure Rating NEMA Type 4, 4X, 6, 6P, 12, 13 (Except Smooth Case 4, 4X, 6, 12)
IEC Type IP67 (Except Smooth Case -- IP63)
Differential (%of Sr.) 20%
Repeatability (% of Sr.) 10%
Electrical AC Models (All) Smooth DC Models
Voltage Range 24 – 240 V 110 – 220 V 12 – 24 V
Voltage Limit 20 – 264 V 90 – 250 V 10 – 38 V
Voltage Drop (across switch) Closed State 5.5 V 9 V 2 V
Minimum Load Current 5 mA 15 mA 0 mA
Maximum Load Current Tubular 300 mA 250 mA (Ue=110Vt) 300 mA
Limit Switch 350 mA 200 mA
Current Consumption @ No Load 10 mA
Residual Leakage Current 1.5 mA at 120V 7 mA
On Delay Max Tubular 50 ms 50 ms 5 ms
Limit Switch 20 ms 5 ms
Off Delay Max. Tubular 50 ms 15 ms 5 ms
Limit Switch 30 ms 5 ms
Power-up Delay Max. Tubular 300 ms 300 ms 30 ms
Limit Switch 150 ms 30 ms
Protective Circuitry
Electrostatic Discharges
IEC 60947-5-2 and NEMA ICS 5, Part 4
Radio Magnetic Fields
Fast Transients
Impulse Voltage
Agency Listings E 164869
CCN NRKH
LR 44087
Class 3211 03
Material εϒFc Material εϒFc
Acetone 20 0.8 Paper 2-4 0.2-0.3
Air 1 0 Paraffin 2-2.5 0.2
Alcohol 24 0.85 Petrol 2.2 0.2
Ammonia 15-25 0.75-0.85 Plexiglass 3.2 0.3
Cement (powder) 4 0.35 Polyester resin 2.8-8 0.2-0.6
Cereals 3-5 0.3-0.4 Polystyrene 3 0.3
Damp wood 10-30 0.7-0.9 Porcelain 5-7 0.4-0.5
Dry wood 2-7 0.2-0.6 Powered Milk 3.5-4 0.3-0.4
Ethylene glycol 38 0.95 Rubber 2.5-3 0.3
Epoxy resin 4 0.36 Salt 6 0.5
Flour 2.5-3 0.2-0.3 Sand 3-5 0.3-0.4
Glass 3-10 0.3-0.7 Sugar 3 0.3
Marble 6-7 0.5-0.6 Teflon 2 0.2
Mica 6-7 0.5-0.6 Vaseline 2-3 0.2-0.3
Nylon 4-5 0.3-0.4 Water 80 1
Oil 2.2 0.2
Size Description Catalog Number
18mm Plastic mounting nuts XSZE218
18mm Metal mounting nuts XSZE118
18mm Plastic mounting bracket XSZB118
18mm Metal mounting bracket 9006PA18
30mm Plastic mounting nuts XSZE230
30mm Metal mounting nuts XSZE130
30mm Plastic mounting bracket XSZB130
30mm Metal mounting bracket 9006PA30
30mm Well mounting bracket XTAZ30
32mm Well mounting bracket XTAZ32
32mm Surface mounting bracket XUZB32
XSZB1kk
9006PAkk
XSZEkkk
XTAZ3k
Well mounting bracket
Wiring
2-wire AC, N.O. or N.C. output
XT1L32F
l
262, XT4L32F
l
262
3-wire DC, N.O. or N.C. output
XT1M12F
l
A372, XT1M12PB372
2-wire AC, programmable
N.O. or N.C. output depending on position of
jumper XT7C40FP262
5
6
L1
L2
GR / YW
BN /1
BU /3
BK /4 (NO)
BK /2 (NC)
+
BN /1
BU /3
BK /4 (NO)
BK /2 (NC)
+
NPN
PNP
12
34
PNP NC
NO
1
2
3
4
NPN
NC
NO
L1
L2
6
5
7
NO
NC
®
Proximity Sensors
XT Capacitive Sensors
12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC
©1997- 2002 Schneider Electric All Rights Reserved
296 10/02
Proximity Sensors
XT Capac itive Sensors / 12 mm, 18 mm , 30 mm, 32 mm and Limit Switch S tyle; AC and D C
Minimum Mounting Clearances
Minimum Mounting Clearances Side by Side
(mm/in)
Face to Face
(mm/in)
Facing a Metal Object
(mm/in)
Mounting in Metal
(mm/in)
XT1
Flush Mountable
18 mm e: 0 e: 30/1.18 e: 30/1.18 d: 18/.71 h: 0
30 mm e: 0 e: 60/2.36 e: 60/2.36 d: 30/1.18 h:0
32 mm e: 0 e: 100/3.94 e: 100/3.93 d: 32/1.26 h:0 x: 2/.07
XT4
Non-Flush Mountable
18 mm e: 40/1.57 e: 50/1.97 e: 80/3.15 d: 18/.71 h: 0
30 mm e: 60/2.36 e: 80/3.15 e: 100/3.94 d: 90/3.54 h: 20/.79
32 mm e: 60/2.36 e: 100/3.94 e: 100/3.94 d: 96/3.78 h: 25/.98
XT7 Limit Switch Style e: 40/1.57 e: 120/4.72
e
e e
d
Mounted in metalFacing a metal objectFace to faceSide by side
h
ee
Sensitivity adjustment
potentiometer
Flush mountingFace to faceSide by side
To avoid influence of the immediate surroundings
it maybe necessary to reduce the sensitivity when
flush mounting the sensor.
Proximity Sensors
XT Capacitive Sensors
12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC
297
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XT Capac itive Sensors / 12 mm, 18 mm , 30 mm, 32 mm and Limit Switch S tyle; AC and D C
Dimensions (mm/in.)
XT1/4 XT7
(1) Output LED
(2) Supply LED (depending on model)
(3) 1 entry threaded for 0.5 NPT
(4) 2 elongated holes 5.3 X 7mm (0.21 X 0.28")
Accessories Dimensions (mm/in.)
XSZB112, B118, B130 XUZB32
XTAZ30 XTAZ32
9006PA
ll
Type ABCDE FGHJ KLM
IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm
PA30 2.54 67 2.56 65 1.39 35 1.99 51 0.39 10 1.28 33 1.97 50 0.21 5 2.05 52 1.20 31 0.08 2 0.98 25
PA18 2.05 52 1.97 50 0.98 25 1.60 41 0.39 10 0.98 25 1.38 35 0.21 5 1.65 42 0.73 19 0.08 2 0.79 20
PA12 1.38 35 1.57 40 069 18 1.20 31 0.39 10 069 18 0.98 25 0.21 5 1.28 33 0.49 13 0.08 2 0.71 18
a
a
b
a = Overall
b = Threaded Section
Dimensions (mm/in) a b
XT
l
M18 60/2.36 51/2.03
XT
l
M30 60/2.36 51/2.03
XT
l
M32 80/3.15 n/a
40
1.57
40
1.57
117
4.6
(3)
16
.63
41
1.6
24
.94
(4)
(2) (1)
.79
20
.98
25
2.36
60
30
40 1.18
1.57
2 x O 5.3
2 x 0.21
dia.
38.3
1.51
(1)
Dia.
4
.16
22
.86
8
.31
b
b2
b1
3.
5
.14
a1
a
(1) 2 elongated holes 4 X 8mm (0.16 X 0.31 in)
XSZ a a1 b b1 b2 Dia.
B112 21.9
0.86
14.5
0.57
16
0.63
15.5
0.61
8.5
0.33 12
B118 26
1.02
15.7
0.62
22
0.87
20.1
0.80
11.5
0.45 18
B130 39
1.53
21.7
0.85
35.5
1.40
31
1.22
18.5
0.73 30
15
.69
32mm Dia
(2)
(2)
50
1.97
60
2.36
25 (1)
.98 40
1.57
1.26" Dia
(1) maximum value
(2) 2 holes 5.5mm (.22 in)
Clamp supplied with two M5 screws. HM head
2.00 .37
1.00
1.00
1.312
1.219 dia.
1 1/2 X 12 UNF
Thread
M30 X 1.5
2.00 dia.
1.75
.06
2.00 .50
1.00
1.348
1.219 dia.
1 1/2 X 12 UNF
Thread
2.00 dia.
1.75
.06
10/32 Set screw
50.8
44.4
9.39
25.4
50.8
25.4
1.52
30.9
50.8
44.4
25.4
50.8
1.52
30.9
34.2
12.7
C
E
D
B
Full R
H
F
A
G
L
M
"K" hole
J
Proximity Sensors
XS Inductive Sensors
Mounting Accessories
©1997- 2002 Schneider Electric All Rights Reserved
298 10/02
Proximity Sensors
XS Inductive Sensor s / Mounting Accessories
Protective fuses
For AC and AC/DC proximity sensors which do not incorporate overload and short circuit
protection, the use of a “quick- blow” fuse connected in series with the sensor is recommended.
Description Catalog Number
0.6A “quick-blow” cartridge fuse (5x20)
(XSB proximity sensors)
(Use with 9080 IEC 5 X 20 fuse block - See Digest 172, page 22-17)
Sold in lots of 10 XUZE06
0.8A “quick-blow” cartridge fuse (5x20)
(XS dia. 8, 12, 18, 30, and XSD proximity sensors)
(Use with 9080 IEC 5 X 20 fuse block - See Digest 172, page 22-17)
Sold in lots of 10 XUZE08
Mounting brackets
Description Sensor Diameter For use with Catalog Number
Cylindrical inductive
proximity sensors
4 unthreaded XS1L04 XSZB104
5 (M5 x 0.5) XS1N05 XSZB105
6.5 unthreaded XS1/XS2 L06 XSZB165
8 (M8 x 1) XS1/XS2/XS4 XSZB108
12 (M12 x 1) XS1/XS2/XS4 XSZB112
9006PA12
18 (M18 x 1) XS1/XS2/XS4 XSZB118
9006PA18
30 (M30 x 1.5) XS1/XS2/XS4 XSZB130
9006PA30
Zinc die cast
for cylindrical
4-12 mm dia.
4mm XS1L04 831604
5mm XS1L05 831605
6mm XS1/XS2 L06 831606
8mm XS1/XS2/XS4 831608
12mm XS1/XS2/XS4 831612
Metal plate bracket Straight XSE XSEZ01
Right angled XSE XSEZ02
Mounting nuts
Description Sensor Diameter For use with Catalog Number
2 Zamac nuts, nickel and
chromium plated
with 2 lock washers
5 (M5 x 0.5) XS1N05 XSZE105
8 (M8 x 1) XS1/XS2 XSZE108
12 (M12 x1) XS1/XS2 XSZE112
18 (M18 x 1) XS1/XS2 XSZE118
30 (M30 x 1.5) XS1/XS2 XSZE130
2 Plastic nuts
8 (M8 x 1) XS4 XSZE208
12 (M12 x1) XS4 XSZE212
18 (M18 x 1) XS4 XSZE218
30 (M30 x 1.5) XS4 XSZE230
Stainless steel
mounting nuts
12 (M12 x1) XS1/XS2 XSZE312
18 (M18 x 1) XS1/XS2 XSZE318
30 (M30 x 1.5) XS1/XS2 XSZE330
Stainless steel
locknut washers
8 (M8x1) XS1/XS2 XSZE908
12 (M12 x1) XS1/XS2 XSZE912
18 (M18 x 1) XS1/XS2 XSZE918
30 (M30 x 1.5) XS1/XS2 XSZE930
Protective cable end,
(CNOMO type)
12 XS1/XS2/XS4 XSZP112
18 XS1/XS2/XS4 XSZP118
30 XS1/XS2/XS4 XSZP130
Flat mounting plate
–XSJXSZBJ00
–XSFXSZBF00
–XSEXSZBE00
–XSCXSZBC00
–XSDXSZBD00
90° Angle flat mounting plat
–XSJXSZBJ90
–XSFXSZBF90
–XSEXSZBE90
–XSCXSZBC90
–XSDXSZBD90
Substitution mounting bracket
–XSEXSZBE10
–XSCXSZBC10
–XSDXSZBD10
Protective cover
–XSEXSZEE10
–XSCXSZEC10
–XSDXSZED10
XUZE08
8316kk
XSEZ01 XSEZ02
XSZP1kk
XSZEkkk
XSZB1kk
9006PAkk
XSZBk00
Proximity Sensors
XS Inductive Sensors
Mounting Accessories, Dimensions
299
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS Inductive Sensor s / Mounting Accessories, Dime nsions
Mounting brackets
XSZB104/105 XSZB165/108/112/118/130
XSEZ01 XSEZ02
Approximate Dimensions
9006PAkk 8316 Bracket
Type ABCDEFGHJ KL M
IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm
PA30 2.64 67 2.56 65 1.39 35 1.99 51 0.39 10 1.28 33 1.97 50 0.21 5 2.05 52 1.20 31 0.08 2 0.98 25
PA18 2.05 52 1.97 50 0.97 25 1.60 41 0.39 10 0.98 25 1.38 35 0.21 5 1.65 42 0.73 19 0.08 2 0.79 20
PA12 1.38 35 1.57 40 0.69 18 1.20 31 0.39 10 0.69 18 0.98 25 0.21 5 1.28 33 0.49 13 0.08 3 0.71 18
e
c
a
h
d2
.13
3.5
1.50
38.3
b
.15
4.86
22 .31
82 elongated holes 4 (screw) x 8
.59
15
.31
8
.15
4
.33
8.5
.48
12.3
d1
6.7
.11
3
==
.35
9
2 X 3
(screw)
Sensors Brackets d1 d2 a b c e h
IN mm IN mm IN mm IN mm IN mm IN mm IN mm
4mm
Unthreaded XSZB104 .15 4
5mm XSZB105 .19 5
6.5 mm
Unthreaded XSZB165 .25 6.5 .78 19.9 .55 14.0 .57 14.5 .29 7.5 .49 12.5
8mm XSZB108 .31 8.0 .78 19.9 .55 14.0 .57 14.5 .29 7.5 .49 12.5
12mm XSZB112 .47 12.0 .86 21.9 .63 16.0 .57 14.5 .33 8.5 .21 15.5
18mm XSZB118 .70 18.0 1.00 26.0 .86 22.0 .61 15.7 .45 11.5 .79 20.1
30mm XSZB130 1.18 30.0 1.53 39.0 1.40 35.5 .85 21.7 .72 18.5 1.20 31.0
.39
10
.31
8
.15
4
==
.78
20
.07
2
1.97
50
.98
25
.47
12
.49
12.5
.98
25
2 X
M3
.47
12
.07
2
1.61
41
1.97
50
.15
4
8
.98
25
.78
20
.35
9
2 X
M3
=
=
Full R
J
C
E
DB
G
H
F
A
"K" Hole
L
M
Dual Dimensions inches
mm
.625
1.5
.980
.625
.201 dia thru
.375 dia C bore
No. 8-32 UNC
2B Type 2 tap
.260 dia
Proximity Sensors
XS Inductive Sensors
Mounting Accessories, Dimensions
©1997- 2002 Schneider Electric All Rights Reserved
300 10/02
Proximity Sensors
XS Inductiv e Sensors Mounting Acc essories, Dimens io ns
XSZBJ00 XSZBF00
XSZBE00 XSZBC00
XSZBD00 XSZBJ90
XSZBF90 XSZBE90
0
.74
19
0.39
0
0
.
31
8
0
.
88
22.
5
0.21
0
5
.
5
0.47
12
0
.2
0
5
.
1
M
3
M
3
1
.
08
2
7.
5
0
.
06
15
1.
35
3
4.
5
0.27
7
0
.7
8
2
0
0.24
6.1
M
3
M
3
0
.4
0
1
0
0
.4
7
11.
9
0.23
3
0
6
0
.
6
7
17
1
.
08
27.4
1.
90
4
8
.
5
0
.2
0
5
M
3
0
.
63
1
6
0.47
0
12
0.39
0
10
1
.1
8
30
1
.
6
42
3
.
0
77.2
0
.1
8
4.
5
M
5
3
.14
80
3
.1
4
80
3
.2
9
83
.7
0
.4
0
1
0
.
2
0.16
0
4
4
14
M
3
M
3
0.47
0
12
0.20
5
.
1
0
.
88
22.
5
0
.
31
8
0.41
1
0
.
5
9
1.2
32
0
.7
2
1
8
.
5
0
.
59
15
0
.7
8
2
0
6
.
1
M
3
M
3
M
3
16
1.35
3
4.
5
45
4
5
4
.
5
0
.4
0
1
0
1
.
08
27.4
0
.
6
7
17
0
.
94
2
3
.
9
1.1
5
2
9
.
4
1.21
30
.
8
M
3
Dual Dimensions inches
mm
Proximity Sensors
XS Inductive Sensors
Mounting Accessories, Dimensions
301
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XSZBC90 XSZBE10
XSZBD10 XSZBC10
XSZEE10 XSZEC10
XSZED10
0
.
63
1
6
0
.
39
10
1.18
1
30
1.
65
42
1.74
44.3
1.74
44.4
1.4
5
36
.
9
36 9
M
5
1
.
6
7
4
2.
5
1.
37
35
3
1.
53
39
39
0.98
25
M
3
3.14
80
3.14
80
2.55
65
2.55
65
0.55
14
M
5
1.65
42
1.61
41
2.16
55
1.18
30 1.61
41
0.11
2.8
M
5
0
.7
8
20
1
.1
8
30.2
30 2
1.1
8
30
.
2
1.1
5
47.1
0
.2
6
6
.
8
M
3
20
M4
0
.
30
7.
8
1
.2
9
33
33
1.74
44.2
1.2
9
3
3
2.44
6
2.
1
0
.
64
1
6
.
4
3
.4
8
88
.
5
0.55
14
0
2
.55
65
M
5
2.
55
65
1.1
3
2
8
.
8
3
.4
8
88
.
5
4.
51
114.
8
Dual Dimensions inches
mm
Proximity Sensors
SG Magnet Actuated Sensors
Surface Mounted Style
©1997- 2002 Schneider Electric All Rights Reserved
302 10/02
Proximity Sensors
SG Mag net Actuated Se nsors / Surface Mounted St yle
Surface mounted magnet actuated sensors for industrial applications.
Sensing is independent of magnet polarity
Typical applications: security systems (gate interlocks), high speed rotational counting,
identification of metal bins with magnet coded “labels”, sensing through non magnetic walls,
etc.
Features:
Housing; aluminum, plastic (PBT) for SG08168 and SG28195
Completely epoxy encapsulated
Very fast response time (reed output only)
PLC compatible AC models (triac output)
High transients protection (AC models)
No bouncing.
PLC applications:
P = PLC compatible.
R = Bleeder resistor required.
jFor reed output: max. voltage. For triac output: nominal voltage.
aUL Recognized
All block sensors except SG28195.
Magnet actuated proximity sensors
Circuit
Type
AC ratings DC ratings Leakage
(mA)
Dim.
Fig.
No.
Wiring
Fig.
Catalog
Number
VA
(max.) Volts jCurrent
(max.)
VA
(max.)
Volts
(max.)
Current
(max.)
Reed output - DC only
N.O. - - - 10 200 0.5 A 0 1 A SGA8016
N.O. - - - 10 200 0.5 A 0 2 A SGA8031
Reed output - DC only - built-in resistor protection
N.O. - - - 10 200 0.5 A 0 1 A SGA8182
Reed output - DC only - High temperature -40° F to 300° F
N.O. - - - 10 200 0.5 A 0 1 A SGA8053
Reed output - AC and DC - built-in RC protection
N.C. 3 130 0.25 A 3 100 0.25 A 6 (R) 2BSGB8175
N.O. 10 130 0.5 A 10 200 0.5 A 6 (R) 2ASGA8176
N.O. 10 130 0.5 A 10 200 0.5 A 6 (R) 1ASGA8177
Triac output - AC only (inductive PLC)
N.O. 240 120 2.0 A 1.7 (P) 3ASG08168 a
N.O./N.C. 50 240 0.5 A 1.7 (P) 3CSG28195 a
N.O. 50 130 0.5 A 1.7 (P) 1ASG08239
Magnet actuators
Sensing distance Catalog
Number
All SG2 8195
Tubular 1.3" (33mm) 1" (25.4mm) 7046
Flat bracket, center South pole 0.7" (17.7mm) 0.4" (10mm) 7093
Flat bracket, side South pole 0.5" (12.7mm) 0.2" (5mm) 7063
90° bracket South pole 0.5" (12.7mm) 0.2" (5mm) 7062
Block type 0.5" (12.7mm) 0.2" (5mm) 7099
Flexible tape 1' long 0.3" (7.6mm) 0.2" (5mm) 7096
made in USA
R.B. Denison
Mag. Switch
200VDC/0.5A MAX
10VA MAX. (RES.)
Telemecanique
SGA-8016
80
Proximity Sensors
SG Magnet Actuated Sensors
Surface Mounted Style
303
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
SG Mag net Actuated Se nsors / Surface Mounted St yle
Specifications
Voltage drop = IR where I= load current, R = 150
Ex: SGO8168L05
Dimensions
Mechanical
Standard temperature range -40° F to +140° F (-40° C to +60° C) (to 300° F for SGA 8053)
Enclosure ratings (NEMA) Type 1, 4, 13
Vibration resistance 20 G (10 to 2000 Hz)
Shock resistance 50 G for 11 mS
Differential Max. 75%
Repeatability 0.003"
Electrical AC (triac) DC
Voltage drop (across switch) 2 V 0 V (IR for SGA8182)
Minimum load current 15 mA -
On delay (ms) 1 ms 0.75 ms
Off delay (ms) 8 ms 0.75 ms
Cable 3' #22 AWG vinyl except SGO8168: #16 AWG SJTO, 2 individual Teflon #22 AWG for SGA8053
Agency Listings E 42259
CCN NKCR2 (SGO8168 and SG28195 only)
Options
Cable Type Suffix
2 meters (6') of individual wires Teflon (SGA8053) L02
5 meters (16') of individual wires Teflon (SGA8053) L05
5 meters (16') of cable Vinyl L05
SJTO (SGO8168) L05
10 meters (33') of cable, (for triac and models with built
in resistor)
Vinyl L10
SJTO (SGO8168) L10
Wiring
LOAD
LOAD
LOAD
LOAD
Red
White
Figure A (N/O)
Figure B (N/C)
Figure C (N/O or N/C)
Black
®
.625
15.88
2.080
52.82
1.562
39.67
.980
24.89
2.00
50.8
1.00
25.4
.875
22.2
2 x .187 dia.
.5" NPT
conduit
entrance
1.25
31.75
1.25
31.75
.75
19
1.25
31.75
.875
22
1.00
25
1.75
44
.200 dia. .406 dia. C. Bore
.310
7.87
Figure 1
SGA8016
SGA8177
SGA8182
SGA8053
SGO8239
Figure 2
SGA8031
SGA8175
SGA8176
Figure 3
SGO8168
SG28195 Dual Dimensions inches
mm
Proximity Sensors
SG Magnet Actuated Sensors
Limit Switch Style
©1997- 2002 Schneider Electric All Rights Reserved
304 10/02
Proximity Sensors
SG Mag net Actuated Se nsors / Limit Switch Style
Limit switch style magnet actuated proximity sensors for heavy duty industrial applications.
Sensing is independent of magnet polarity
Typical applications: security systems (gate interlocks), high speed rotational countings,
identification.
Features:
Housing; zinc die-cast
Completely epoxy encapsulated
Plug in models for fast replacement
Very fast response time (reed output only)
PLC compatible AC models
High transient protection
Overload and short protection (transistor models)
No bouncing
0.5" NPT conduit entrance.
UL recognized (except where indicated).
q(P)=PLC compatible. (R) Bleeder resistor required for PLC compatibility.
tAll sensors except the ones tabulated separately at right.
Circuit
Type
AC ratings
(inductive or resistive) VA
(max.)
DC ratings
(resistive only) Leakage
(mA)
Dim.
Fig.
No.
Wiring
Fig.
Catalog
Number
VA
(max.)
Volts
(nom.)
Current
(max.)
Volt s
(max.)
Current
(max.)
AC triac output, non plug-in
N.O. 360 120 3.0A 1.7 (P)q1ASG08003
N.C. 360 120 3.0A 1.7 (P)q1BSG18004
Non plug-in with light indicator
N.O. 360 120 3.0A 1.7 (P)q1ASG0L8003
N.C. 360 120 3.0A 1.7 (P)q1BSG1L8004
DC, transistor output, non plug-in
N.O. - - - 7.5 30 0.25 A 0 1 D SG08079
N.C. - - - 7.5 30 0.25 A 0 1 E SG18056
Reed output, non plug-in (AC model has built-in surge RC protection)
N.O. - - - 10 200 0.5 A 0 1 A SGA8005
N.O. 15 120 1.0A 15 250 1.0 A 6 (R)q1ASGA8040
N.O./N.C. - - - 3 200 0.25 A 0 1 C SGC8027
N.O./N.C. - - - 20 500 1.5 A 0 3 C SGC8025
Magnet actuators (See page 310) inches (mm)
To
all
others
8079
Sensing distance
8025 Catalog
Number
8040 8027
Tubular 1.3" (33) 1.2" (30.5) 0.8" (20.3) 0.9" (23) 1" (25.4) 7046
Flat bracket, center South pole 0.7" (17.7) 0.5" (12.7) 0.4" (10.1) 0.4" (10.1) 0.4" (10.1) 7093
Flat bracket, side South pole 0.5" (12.7) 0.4" (10.0) 0.2" (5.1) 0.2" (5.1) 0.2" (5.1) 7063
90° bracket South pole 0.5" (12.7) 0.4" (10.1) 0.2" (5.1) 0.2" (5.1) 0.2" (5.1) 7062
Block type 0.5" (12.7) 0.2" (5.1) 0.2" (5.1) 0.3" (7.6) 0.2" (5.1) 7099
Flexible type - 1' long 0.3"(7.6) 0.1" (2.5) 0.2" (5.1) 0.1" (2.5) 7096
Non plug-in
Proximity Sensors
SG Magnet Actuated Sensors
Limit Switch Style
305
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
SG Mag net Actuated Se nsors / Limit Switch Style
Specifications
See p. 518 for matching connector cables.
Dimensions
General characteristics
Temperature range -40° F to 140° F (-40° C to 60° C)
-40° F to 125° F (-40° C to 52° C) for transistor models
Enclosure ratings NEMA Type 1,4,13
Vibration resistance 20G (10 to 2000Hz)
Shock resistance 50G for 11ms
Differential Max. 75%
Repeatability 0.003"
AC triac Transistor Reed
Voltage drop (across switch) 2 V
Minimum load current (max.) 15 mA
SGA8005 SGA8040 SGS8027 SGC8025
On delay (max.) 1 ms 0.75 ms 0.75 2 ms 1 ms N.O./
1.5 ms N.C.
2 ms N.O./
4 ms N.C.
Off delay (max.) 0.75 ms 0.75 2 ms 11 msN.O.
1.5 ms N.C.
2 msN.O./
4 ms N.C.
Cable - screw terminals #16 AWG
Agency Listings
except where noted
E 42259
CCN NKCR2
Options - triac models only
Description Fig. Suffix adder
3' 16-3 SJTO vinyl cable, epoxy sealed A,B 320
3' 16-3 SJTO vinyl cable, cord connector A,B 321
3' 16-4 SJTO vinyl cable, epoxy sealed C,D,E 420
3 pin mini style receptacle 347
Wiring
LOAD
LOAD
LOAD
LOAD
Figure A
Figure B
Figure C
Com
LOAD
Figure D
L1 L2
L1 L2
NO
NC
Com
++-
Terminal strip marked: NO-COM-NC
SG18056 is normally closed. Connect
red terminal (+) to power source.
Connect minus (-) terminal to load.
Housing must be connected to minus.
LOAD
Figure E
+Com
+
®
3.42
86
.84
21
1.75
44
.28
7
.71
18
2.34
59
1.15
29
1.62
41
2.34
59
1.34
34
4.06
103
1.15
29
1.62
41
1.75
44
.84
21
Sensing face Sensing face
#10-32 x .375 deep
Mtg. holes tapped
from back
.203 dia.
Mtg holes.
thru
#10-32 x .375 deep
Mtg. holes tapped
from back
.203 dia.
Mtg holes.
thru
Figure 2
Style C
SGC8025
Dual Dimensions inches
mm
Figure 1
non-plug-in
SGA8005
SGO8003
SGC8027
SGI8056
SGO8056
SGI8004
SGO8040
SGO8079
Proximity Sensors
SG Magnet Actuated Sensors
Tubular Style
©1997- 2002 Schneider Electric All Rights Reserved
306 10/02
Proximity Sensors
SG Magnet Actuated Sensors / Tubular S tyle
Tubular magnet actuated proximity sensors for heavy duty applications such as: high speed
rotational counting, identification of metal bins with magnet coded “labels” sensing through
non-magnetic walls, etc.
Sensing is independent of magnet polarity
Features:
Housings - Aluminum SGA8057; Plastic PVC SGC8058, SGA8072, SGA8039; Polymide
SGA8179, SGA8180, SGA8181
Completely epoxy encapsulated
High transient protection
Threaded and smooth housings
High voltage versions
SPST and SPDT models
No bouncing.
UL recognized (except where noted with a).
Bleeder resistor required for PLC AC switching compatibility.
150 for SGA8180 and 470 for SGC8181.
aNot UL
tAll except SGA8180 tabulated at right.
Circuit
type
AC ratings
(inductive or resistive)
DC ratings
(resistive only) Leakage
(mA)
Dim.
Fig.
No.
Wiring
Fig.
Catalog
Number
VA
(max.)
Volt s
nominal
Current
(max.)
VA
(max.)
Volts
(max.)
Current
(max.)
Reed output AC & DC switching (Built-in RC protection), threaded.
N.O. 15 120 1.0 A 12 48 0.25 A 6 1A SGA8057
N.O./N.C. 15 120 1.0 A 15 100 1.0 A 6 1C SGC8058
N.O. 15 120 1.0 A 15 250 1.0 A 6 1A SGA8072
N.O. 25 480 1.0 A 25 480 1.0 A .16 2 A SGA8179 a
Reed output - DC, threaded, resistor built-in for long cable runs
N.O.–––102000.5 A02ASGA8180 a
N.O./N.C.–––31000.25 A02CSGC8181 a
Reed output - AC & DC (built-in RC protection), smooth
1 N.O. 15 120 1.0 A 15 250 1.0 A 6 3A SGA8038 a
Magnet actuators (See page 310)
Description Sensing
distance tSGA8180 Catalog Number
Tubular 0.8" (20.3) 1.3" (33) 7046
Flat bracket, center South pole 0.4" (10.1) 0.7" (17.8) 7093
Flat bracket, side South pole 0.2" (5.1) 0.2" (5.1) 7063
90° bracket South pole 0.2" (5.1) 0.2" (5.1) 7062
Block type 0.2" (5.1) 0.2" (5.1) 7099
Flexible tape - 1' long 0.1" (2.5) 0.1" (2.5) 7096
2.25
57
1.25
31
1"-14
UNS
-2A
Thread
1.00
25
3.25
82
.1/2" NPT
conduit
entrance
1.00
25
.70
18
M18 x 1 Thread
2 locking nuts
furnished with
each sensor
.15
4
1.09
27
.945
24
2.13
54.1
2.72
69
Figure 1
SGA8057
(Aluminum)
SGC8058 (PVC)
SGA8072 (PVC)
SGA8189 (Brass)
Figure 2
SGA8179
SGA8180
SGC8181
Figure 3
SGA8038
Dual Dimensions inches
mm
Proximity Sensors
SG Magnet Actuated Sensors
Tubular Style
307
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
SG Magnet Actuated Sensors / Tubular S tyle
Specifications
Voltage drop = IR, where I is load current and R built-in resistor.
General characteristics
Temperature range -40° F - 140° F (-40° C to 60° C)
Enclosure ratings NEMA Type 1,4,13
Vibration resistance 20G (10 to 1000Hz)
Shock resistance 50G for 11mS
Differential Max. 75% (except SGA8179 = 1.06" max.)
Repeatability Max. 0.003"
Reed AC & DC SGA8180
Built in resistor (DC)
SGC8181
Built in resistor (DC)
Voltage drop 25 mV I x R I x R
On delay (max.) 2 mS 0.75 ms 2.5 ms N.O.
3.5 ms N.C.
Cable, 3' 22-2 vinyl: SGA8038, 8180; 23-2 vinyl SGC 8181;
16-2 SJTO: SGA8057, 8072. SO cable for SGA8179
Agency Listings
except where noted
E 42259
CCN NKCR2
Options
Description Suffix
5 meters (16') of cable Vinyl L05
SJTO (8057, 8072, 8179) L05
10 meters (33') of cable
(for models with built in resistor)
Vinyl L10
SJTO (8057, 8072, 8179) L10
Wiring
LOAD
L1 L2
LOAD
LOAD
Com
NO
NC
L1 L2
Figure A
Figure C
SGC8058 & SGC8181
Black – Com
Blue – N.O.
Brown – N.C.
®
Proximity Sensors
SG Magnet Actuated Sensors
Maintained Contact
©1997- 2002 Schneider Electric All Rights Reserved
308 10/02
Proximity Sensors
SG Magnet Actua ted Se nsors / Main tained Contac t
Maintained contact model - A highly reliable magnet actuated proximity limit switch designed
to maintain contact for high speed stacker cranes, slow down and memory applications.
Eliminates camming required for mechanically operated limit switches. Maintains the
information even if power is down.
Movement of an N or S pole of a magnet actuator past the “blue dot” sensitive area within the
specified range along the switch will change the contact position from open to closed. Once
latched, the movement of the same magnetic pole in the opposite direction or the movement
of the opposite magnetic pole in the same direction will unlatch the switch.
Features:
Housing - zinc die cast
PLC compatibility
High transient protection
No bouncing
0.5" NPT conduit entrance
UL recognized.
CSA certified.
NOTE: If during this procedure the switch closes and then opens again (pulses), reverse the
polarity of the magnet and repeat above procedure. If desired direction of operation is opposite
to that established above, reverse polarity of the magnet.
Circuit
Type
AC ratings
(inductive or resistive)
DC ratings
(resistive only) Leakage
(mA)
Wiring
Fig.
Catalog
Number
VA
(max.)
Volt s
(nom.)
Current
(max.)
VA
(max.)
Volts
(max.)
Current
(max.)
Reed, DC
1 N.O. 15 250 1.0 A 0 A SGA8018
Triac, AC
1 N.O.3601203.0 A –––1.7 A SGO8026
Triac, AC low temperature: -30° F to 85° F
1 N.O.3601203.0 A –––1.7 BSGO8110
Magnet actuators (see page 310)
Description Sensing Distance Catalog Number
Tubular 1.3" 7046
Flat bracket, center South pole 1.0" 7093
North pole 1.0" 7547
Flat bracket, side South pole 0.7" 7063
North pole 0.7" 70631
90° bracket South pole 0.7" 7062
North pole 0.7" 70621
Block type 0.5" 7099
Flexible tape - 1" long 0.5" 7096
1.25
31
.94
23
3.88
98
3.06
77
.75
19
.69
17
1.93
49
1.44
36 1.75
44
Sensing face
.203 dia.
thru mtg
holes
.5" pipe tap
3.50
88
1.06
26
1.44
36
.18
4
.203 dia.
thru mtg
holes
.19
4
Figure 1
SGA8018
SGO8026
SGO8110
SGO8141
Dual Dimensions inches
mm
Proximity Sensors
SG Magnet Actuated Sensors
Maintained Contact
309
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
SG Magnet Actua ted Se nsors / Main tained Contac t
Specifications
Mechanical
Temperature range +32° F to 140° F (0° C to 60° C)
+30° F to 85° F (-35° C to 30° C) for SGO8110
Enclosure ratings NEMA Type 1, 4, 13
Vibration resistance 20 G (10 to 2000 Hz)
Shock resistance 50 G @ 11 ms
Differential Max. 50%
Repeatability Max. 0.003"
Electrical Reed Triac
Voltage drop 3 V
Minimum load current (mA) 15 mA
On delay mS 2 ms 2 ms
Off delay mS 2 ms 2 ms
Cable - screw terminals #16 AWG
Agency Listings E 42259
CCN NKCR2
LR 25490
Class 3211 03
Wiring
LOAD
Figure A
L1 L2
LOAD
Figure B
L1 L2
6.8k
2
3
1
Connect terminal 3 (heater) to line
(L2) for operation below +32°F.
®
Proximity Sensors
SG Magnet Actuated Sensors
Magnet Actuators
© 1997-2002 Schneider Electric All Rights Reserved
310 10/02
Proximity Sensors
SG Magnet Actuated Sensors / Magnet Actuators
Features:
Industrial grade magnet recommended for magnet actuated proximity sensors.
Alnico is used as magnet material for all rigid models.
Kevlar is used for the flexible magnetic tape.
The rigid models are already mounted on several types of standard brackets for
convenience (except the tubular “high power” version).
Both South and North Poles are accessible and marked. The South Pole version is the
standard. North Pole versions may be required in conjunction with the maintained magnetic
switch (see page 308).
For comparison an average magnetic strength rating is listed below. Measurements were
made with a Gaussmeter at 0.13" from the sensing surface.
t For longer tape specify total length in feet. Example: 70966 = 6 feet.
Description Magnetic Strength Catalog Number
Tubular 700 Gauss 7046
Flat bracket, center South pole 330 Gauss 7093
North pole 330 Gauss 7547
Flat bracket, side South pole 240 Gauss 7063
North pole 240 Gauss 70631
90° bracket South pole 260 Gauss 7062
North pole 260 Gauss 70621
Block type 340 Gauss 7099
Flexible tape 1' long 180 Gauss 7096t
7046
7093
7063
7062
7099
7096
Proximity Sensors
SG Magnet Actuated Sensors
Magnet Actuators
311
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
SG Magnet Actuated Sensors / Magnet Actuators
Magnet actuator dimensions
Tubular magnet actuator 7046 Magnet actuator 7093 (south pole)
Magnet actuator 7597 (north pole)
Magnetic actuator 7063 (south pole)
Magnet actuator 70631 (north pole)
Magnet actuator 7062 (south pole)
Magnet actuator 70621 (north pole)
Block type magnet actuator 7099 Flexible magnetic tape 7096 1 foot
3.0
76
.62
15
SN
S
S
S
2.56
65
.34
8
.50
12
3.25
82
.50
12
.12
3
1.00
25
.31
7
4 holes
.18" dia
1.50
38
.75
19
3.37
85
3.75
95
.50
12
.87
22
.31
7
.50
12
.12
3
2 holes
.266" dia.
2.37
60
1.50
38
.37
9
.37
9
.75
19
.50
12
2 holes
.266" dia.
.87
17
1.00
25 1.75
44
.43
10
.75
19
.62
15
1.25
31
2 holes thru
.18" dia.
Ainico
magnet
1' standard length
1.00
25
.18
4Dual Dimensions inches
mm
Proximity Sensors
ST Grounded Probe Switch
© 1997-2002 Schneider Electric All Rights Reserved
312 10/02
Proximity Sensors
ST Grounded Probe Switch
The touch switch is a highly reliable AC solid state presence sensor designed for precise
conductivity sensing. Applications include high temperature environment, light conductive,
aggressive mechanical and chemical environments that targets positive end-point sensing. All
models have a visible neon pilot light to indicate operation of the switch.
Features
Housings - zinc die cast
Solid state - no moving parts
115 Vac completely self-contained
Probes up to 10 feet long
High current output - no relay required for most applications
Fast response - no warm-up time
0.5" NPT conduit entrance
UL Recognized
Operation
The switch is actuated when a conductive path between probe terminal and ground (1 M or
less) is established. The electrical contact to ground operates the switching thyristor. Internal
RC snubber and varistor provide effective protection from typical transients. Normal open
models have a 10 millisecond (maximum) turn on time. Different off delay times are offered in
order that the design engineer may compensate for relay chatter when the probe is subjected
to “bounce” from irregular contact with the grounded metal point of contact.
NOTE: For isolated circuits where the ground is not common - the switch ground terminal
should be connected to the neutral. The metal target to be detected by the probe should then
be wired also to the neutral.
Probe characteristics
The probe terminal is an 8-32 stud protruding from the center of the head. Extensions may be
any electrically conductive wire or material suitably insulated from grounded surface and
limited in length to 10 feet or less.
Open voltage: 12 Vdc
Peak current: 1 mA
Switch models
Circuit
type
Voltage
(nominal)
Current
load
(max.)
Leakage
current
(max.)
On
delay
Off
delay
Catalog
Number
Terminal screws
N.O. 120 Vac 3 Amp 1.7 mA 10 ms 100 ms STO8164
N.C. 120 Vac 3 Amp 1.7 mA 100 ms 30m s ST18165
N.O. 120 Vac 3 Amp 1.7 mA 10 ms 400 ms STO8166
N.O. 120 Vac 3 Amp 1.7 mA 10 ms 20 ms STO8167
Pre wired with 3 feet of cable
N.O. 120 Vac 3 Amp 1.7 mA 10 ms 100 ms STO8001
N.C. 120 Vac 3 Amp 1.7 mA 100 ms 30 ms ST18002
N.O. 120 Vac 3 Amp 1.7 mA 10 ms 400 ms STO8036
N.O. 120 Vac 3 Amp 1.7 mA 10 ms 20 ms STO8042
1.1562"
1.625"
2.343"
.2812"
1.0312"
.8437"
1.75"
.2812"
8-32
probe
terminal
2 - .203" dia.
mtg holes
10-32 x .375"
deep mtg holes
tapped from back
.375"
2.343"
Proximity Sensors
ST Grounded Probe Switch
313
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
ST Grounded Probe Switch
Specifications
General characteristics
Temperature range -40° F to 158° F (-40° C to 70° C)
Enclosure ratings NEMA Type 1, 4, 13
Voltage drop 2 V
Inrush current maximum 10 Amp
Minimum load current 15 mA
Power supply current (no load) 30 mA
Cable 3' 16-4 SJTO or terminal screws #16 AWG
Wiring
Blk Gnd Wht Red
Cable wiring
L1
hot
L2
neutral
LOAD
Target connected to ground
1 2 3 4
Terminal strip wiring
L1 L2
hot
neutral
LOAD
Target connected to ground
Housing must be grounded for
proper operation.
Not
used
housing
Model ST switches may be wired in
series or parallel. Connect red lead
to black lead of other switch
(terminal 4 to terminal 1 of other
switch) for series operation. The
voltage drop across each switch
(in the closed state) does not
exceed 2 volts AC.
Proximity Sensors
XS7V Magnetic Cylinder Position Sensors
Rectangular, Compact; DC
© 1997-2002 Schneider Electric All Rights Reserved
314 10/02
Proximity Sensors
XS7V Magne tic Cylinder Position Senso rs / Rectangul ar, Compact ; DC
Description
Detects the magnet installed on the piston through a non-ferrous cylinder wall. Universal
mounting provided by clamp style and strap style mounting. Fast troubleshooting aided by output
LED. Trouble-free operation insured by extensive protective circuitry. Connector versions.
t At 11mT.
Application Information
The XS7V sensors detect the magnetic field generated by a magnet. The sensors are mounted in
general on the cylinder. The magnets are mounted on the end of the piston and influence the
sensor through a non- ferrous cylinder wall (i.e. aluminum). The sensors can be mounted anywhere
along the cylinder using mounting accessories such as the ones shown on the next page.
Circuit
type
Nominal Sensing
Range t
Output
mode
Load current
maximum
Voltage
maximum
Mating
connector style
Catalog
Number
2m Cable
PNP 3.5 mm N.O. 100 mA 10-30 Vdc XS7V12PA332
NPN 3.5 mm N.O. 100 mA 10-30 Vdc XS7V12NA332
Connector - Nano style
PNP 3.5 mm N.O. 100 mA 10-30 Vdc 1 thru 8 XS7V12PA332S
NPN 3.5 mm N.O. 100 mA 10-30 Vdc 1 thru 8 XS7V12NA332S
Cylinder
Diameter
Active Travel
CA1
Travel
C1
Hysteresis
H
IN mm IN mm IN mm IN mm
0.39 10 0.28 7.2 0.13 3.25 0.028 0.70
0.47 12 0.31 7.8 0.14 3.45 0.028 0.70
0.63 16 0.33 8.5 0.15 3.80 0.035 0.90
0.79 20 0.37 9.3 0.17 4.20 0.035 0.90
0.98 25 0.40 10.2 0.18 4.60 0.039 1.00
1.26 32 0.43 11 0.20 5.00 0.039 1.00
1.57 40 0.47 12 0.22 5.50 0.039 1.00
1.97 50 0.47 12 0.22 5.50 0.039 1.00
2.48 63 0.55 14 0.26 6.50 0.039 1.00
3.15 80 0.63 16 0.30 7.50 0.039 1.00
3.94 100 0.71 18 0.33 8.50 0.039 1.00
Nano style connector
Cable
Dual Dimensions inches
mm
Proximity Sensors
XS7V Magnetic Cylinder Position Sensors
Rectangular, Compact; DC
315
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
XS7V Magne tic Cylinder Position Senso rs / Rectangul ar, COmp act; DC
Specifications
Mechanical
Sensing range @ 11 mT 0 to 3.5mm
Standard Temperature range Operating -10° C to 60° C (+ 14° F to + 140° F)
Storage -40° C to + 70° C (-40° F to + 158° F)
Enclosure rating NEMA Type
IEC Type IP67
Enclosure material Plastic
Repeatability 0.1 mm
Electrical
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 30 Vdc
Voltage drop (across switch), closed state 0.5 V
Maximum load current 100 mA
Current consumption (no load) 30m A
Actuation speed (max.) 10 ms
Response time 3 ms
Options
Description Suffix
Extended cable length 5 meter cable L1
10 meter cable L2
Accessories
Description Cylinder Diameter mm/in Catalog Number Sold in Lots of
Stainless steel mounting collar 10 / 0.39 XSZB210 5
Stainless steel mounting collar 12 / 0.47 XSZB212 5
Stainless steel mounting collar 16 / 0.63 XSZB216 5
Stainless steel mounting collar 20 / 0.79 XSZB220 5
Stainless steel mounting collar 25 / 0.98 XSZB225 5
Mounting bracket (for cylinder rods) 32 / 1.26 to 40 / 1.57 XSZB240 1
Mounting bracket (for cylinder rods) 50 / 1.97 to 63 / 2.48 XSZB263 1
Mounting bracket (for cylinder rods) 80 / 3.15 to 100 / 3.94 XSZB200 1
Stainless Steel
Mounting Collar
Mounting Bracket
for Cylinder Rods
Wiring
3 wire, PNP
BN/1 +
-
BK/4 (NO)
BU/3
PNP
+
-
NPN
3 wire, NPN
BN/1
BU/3
BK/4 (NO)
Proximity Sensors
Inductive Sensor Accessories
Conduit Adapters for Tubular Sensors
© 1997-2002 Schneider Electric All Rights Reserved
316 10/02
Proximity Sensors
Inductive Senso r Accessories / Conduit Adapte rs for Tubular Sensors
Features:
Available for 12, 18 and 30mm tubular sensors
1/2" – 14 NPT Inside Thread
Nickel Plated Brass
Tube
Diameter
Tube Thread
Size Dimensions (mm) Catalog
Number
12mm (0.47) M12 x 1 XSZCAR12
18mm (0.71) M18 x 1 XSZCAR18
30mm (1.18) M30 x 1.5 XSZCAR30
Proximity Sensors
Inductive Sensor Accessories
Face caps for Tubular Proximity Sensors
317
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Inductive Senso r Accessories / Face Caps for Tubular Proximity Sensors
Features:
Shielded and non-shielded caps available
Different versions available (beveled or non-beveled)
Provides sensor face protection with no effect in operation
Description
Protection in harsh applications, helps to prevent abrasions, cracks, and other possible
damage to the sensors face. Available in many different materials Ceramic, Delrin (Acetal),
and Teflon. Provide your sensor with protection and a longer life without the additional charge
of a stainless steel face option.
Beveled caps (30 ° chamfer)
Non-beveled caps
ABCDECatalog Number
8 mm Diameter shielded
5.1 (0.20) 15.1 (0.59) 0.38 (0.15) 7.00 (0.28) XSZEN08
12 mm Diameter shielded
6.2 (0.26) 24.1 (0.95) 0.76 (0.03) 12.2 (0.48) XSZEN12
18 mm Diameter shielded
8.2 (0.32) 31.2 (1.23) 0.76 (0.03) 17.0 (0.67) XSZEN18
30 mm Diameter shielded
7.6 (0.30) 44.5 (1.75) 1.01 (0.04) 29.0 (1.19) XSZEN30
8 mm Diameter non-shielded
5.1 (0.20) 14.1 (0.56) 0.38 (0.15) 7.00 (2.76) 9.60 (0.37) XSZENN08
12 mm Diameter non-shielded
6.5 (0.26) 22.9 (0.90) 0.76 (0.03) 12.9 (0.51) 17.3 (0.68) XSZENN12
18 mm Diameter non-shielded
8.2 (0.32) 34.0 (1.34) 0.76 (0.03) 16.6 (0.65) 17.8 (0.70) XSZENN18
30 mm Diameter non-shielded
7.5 (0.30) 44.5 (1.75) 1.01 (0.04) 30.0 (1.18) 22.8 (0.90) XSZENN30
A B C Catalog Number
12 mm Diameter shielded
8.90 (0.35) 16.1 (0.63) 1.26 (0.05) XSZSC12C
8.90 (0.35) 16.1 (0.63) 0.76 (0.03) XSZSC12D
8.90 (0.35) 16.1 (0.63) 0.76 (0.03) XSZSC12T
12 mm Diameter non-shielded
15.2 (0.60) 16.1 (0.63) 0.76 (0.03) XSZSC12ND
15.2 (0.60) 16.1 (0.63) 0.76 (0.03) XSZSC12NT
18 mm Diameter shielded
8.80 (0.35) 24.4 (0.96) 1.27 (0.05) XSZSC18D
8.80 (0.35) 24.4 (0.96) 1.27 (0.05) XSZSC18T
18 mm Diameter non-shielded
18.0 (0.59) 24.4 (0.96) 1.27 (0.05) XSZSC18ND
18.0 (0.59) 24.4 (0.96) 1.27 (0.05) XSZSC18NT
B
C
D
30
A
o
B
C
D
30
E
oA
B
C
A
XSZENkk
XSZENNkk
XSZSCkkkk
Dual Dimensions inches
mm
Proximity Sensors
Inductive Sensor Accessories
Plunger Screw Adapters
© 1997-2002 Schneider Electric All Rights Reserved
318 10/02
Proximity Sensors
Inductive Sen sor Accessorie s / Plunger Screw Adap ters
Features
Accepts 8, 12, or 18mm shielded sensor
Heat-treated alloy steel construction
Rugged stop with solid state output
Description
Plunger Screw Adapters provide the ability for a shielded inductive proximity sensor to be used
as a mechanical stop switch. Helps to solve many applications that require precise end of travel
signals, or a hard stop. Spring requires 252g (9oz) to actuate sensor.
ABCDE (Dia.)FGImpact
Force (Max.)
Catalog
Number
8 mm Diameter Shielded Sensors
M8x1 25.0 (1.00) M8x1 3.16 (0.12) 5.84 (0.23) 6.26 (0.24) 11.0 (0.43) 2000 N (450 lb-ft) XSZB0825
M8x1 50.0 (2.00) M8x1 3.16 (0.12) 5.84 (0.23) 6.26 (0.24) 11.0 (0.43) 2000 N (450 lb-ft) XSZB0850
12 mm Diameter Shielded Sensors
M12x1 25.0 (1.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1225
M12x1 50.0 (2.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1250
M12x1 75.0 (3.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1275
M12x1 100 (4.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1210
18 mm Diameter Shielded Sensors
M18x1 25.0 (1.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1825
M18x1 50.0 (2.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1850
M18x1 75.0 (3.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1875
M18x1 100 (4.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1810
D
G
16.7
(0.66)
C
31.8
(1.25)
E
A
F
B
XSZBkkkk
Proximity Sensors
Inductive Sensor Accessories
Proximity Probe Adapters
319
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Inductive Sen sor Accessorie s / Proximity Probe Adapters
Features:
Accepts any 8 or 12mm shielded sensor
Accurate and compact switching in confined areas
Large variety of stand probe lengths and diameters
Description
Proximity Probe is a spring loaded actuator designed to work with 8mm or 12mm cylindrical
inductive proximity sensors. The probe and sensor combination offers increased flexibility in
applications that require tight positioning.
A B C D E (Dia.) F Catalog Number
8 mm Diameter Shielded Sensor
75.6 (2.98) 25.0 (1.00) M8 x 1 to depth of
21.8 (0.86) M8 x 1 3.18 (.125) 11.1 (.436) XSZPP0825
99.6 (3.92) 50.0 (2.00) M8 x 1 to depth of
21.8 (0.86) M8 x 1 3.18 (.125) 11.1 (.436) XSZPP0850
126 (4.96) 75.0 (3.00) M8 x 1 to depth of
21.8 (0.86) M8 x 1 3.18 (.125) 11.1 (.436) XSZPP0875
150 (5.91) 100 (4.00) M8 x 1 to depth of
21.8 (0.86) M8 x 1 3.18 (.125) 11.1 (.436) XSZPP0810
12 mm Diameter Shielded Sensor
75.6 (2.98) 25.0(1.00) M12 x 1 to depth
of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1225
99.6 (3.92) 50.0 (2.00) M12 x 1 to depth
of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1250
126 (4.96) 75.0 (3.00) M12 x 1 to depth
of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1275
150 (5.91) 100 (4.00) M12 x 1 to depth
of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1210
Probe
travel
E
B
F
C
3.90
(0.15)
D
A
17.4
(.685)
XSZPPkkkk
Proximity Sensors
Inductive Sensor Accessories
Quick Change Mounting Tube
© 1997-2002 Schneider Electric All Rights Reserved
320 10/02
Proximity Sensors
Inductive Sen sor Accessorie s / Quick Change Moun ting Tube
Features:
Quick change mounting available for 8,12,18 and 30mm sensors
Short and Long barrel lengths available
One time adjustment, makes sensor replacement easy and quick
Provide protection to sensor from impact and damage
Teflon caps available for quick change mounts (shown below)
Description
Provides time savings in maintenance of sensors, helps prevent downtime. An internal
shoulder stop and a collet-style locknut precisely holds the sensor. This helps to maintain a
precise sensing distance and reduces the required expertise needed during sensor
installation.
Teflon Caps for Quick change mounting tubes
A B C D E F Catalog Number
8 mm Diameter Shielded Sensors
8.18 (0.32) 32.4 (1.28) 17.5 (0.69) M12x1 3.85 (0.15) 16.9 (0.67) XSZQT08
8.18 (0.32) 48.0 (1.90) 34.0 (1.34) M12x1 3.85 (0.15) 16.9 (0.67) XSZQTL08
12 mm Diameter Shielded Sensors
12.1 (0.48) 33.7 (1.34) 19.5 (0.77) M16.5x1.5 4.01 (0.16) 21.8 (0.86) XSZQT12
12.1 (0.48) 44.8 (1.76) 30.0 (1.18) M16.5x1.5 4.01 (0.16) 21.8 (0.86) XSZQTL12
18 mm Diameter Shielded Sensor
18.1 (0.71) 38.5 (1.52) 20.0 (0.79) M24 x 1.5 4.95 (0.19) 30.0 (1.18) XSZQT18
18.1 (0.71) 58.0 (2.28) 40.0 (1.57) M24 x 1.5 4.95 (0.19) 30.0 (1.18) XSZQTL18
30 mm Diameter Shielded Sensors
30.1 (1.19) 35.0 (1.50) 20.0 (0.79) M36 x 1.5 6.13 (0.24) 41.0 (1.61) XSZQT30
30.1 (1.19) 58.0 (2.28 40.0 (1.57) M36 x 1.5 6.13 (0.24) 41.0 (1.61) XSZQTL30
AB CDCatalog Number
8.84 (0.35) 14.8 (0.59) 0.76 (0.03) M12x1 XSZQTC08
7.24 (0.29) 19.9 (0.75) 0.76 (0.03 M16x1 XSZQTC12
9.00 (0.35) 28.7 (1.13) 0.76 (0.03 M24x1.5 XSZQTC18
9.00 (0.35) 41.4 (1.63) 1.26 (0.05) M36x1.5 XSZQTC30
B
C
DE
A
F
XSZQTkkk
DB
C
A
XSZQTCkk
Proximity Sensors
Inductive Sensor Accessories
Spring-loaded Tubular Sensor Mount
321
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Inductive Sensor Accessorie s / Spring-loaded Tubular Se nsor Mount
Features:
Accepts 8, 12, 18 & 30mm shielded or non-shielded sensors
Sensors become unaffected by accidental impact
Shielded and Non-shielded caps available, see page 313.
Description
Spring loaded sensor mount for tubular body styles provides impact protection for the sensor
in the case of target over travel. The mount is designed to be threaded onto a tubular sensor
and held in place by using one of the mounting nuts provided with the sensor. Caps are
available to help protect the face of the sensor from lateral and axial impacts, see page 313.
A
Inside
Thread
B
Outside
Thread
C
Maximum
D
Across Flats
E
Maximum
Over travel
FG
Catalog
Number
8 mm Diameter Sensors
M8 x 1 M16 x 1.5 12.2 (.481) 22.2 (.875) 9.22 (.363) 22.0 (.867) 3.10 (.155) XSZSN08
12 mm Diameter Sensors
M12 x 1 M18 x 1 10.0 (.394) 23.9 (.943) 12.1 (.476) 21.3 (.840) 3.94 (.156) XSZSN12LP
M12 x 1 M22 x 1.5 11.5 (.454) 28.4 (1.12) 10.5 (.413) 22.1 (.871) 3.88 (.153) XSZSN12
18 mm Diameter Sensors
M18 x 1 M30 x 1.5 16.1 (.634) 34.8 (1.37) 13.3 (.523) 29.7 (1.17) 5.08 (0.20) XSZSN18
30 mm Diameter Sensors
M30 x 1.5 M47 x 1.5 24.6 (.972) 50.8 (2.00) 15.6 (.615) 37.0 (1.37) 4.98 (.196) XSZSN30
B
C
DE
A
F
G
XSZSNkk
Proximity Sensors
Flat Inductive Sensing Curves
© 1997-2002 Schneider Electric All Rights Reserved
322 10/02
Proximity Sensors
Flat Inductive Sensing Curve s
Shielded
0mmmm -2-4 2 4
1,5
2
2,5
3
0,5
1
-3 -1 31
Sn (mm)
________ pick up points
- - - - - - - - drop out points
Target size Usable range
mm mm
XS7J1A1D 5 x 5 x 1 0 . . . 2
0mmmm -4-8 4 8
3
5
6
1
2
-6 -2 62
4
Sn (mm)
________ pick up points
- - - - - - - - drop out points
Target size Usable range
mm mm
XS7F1A1D 5 x 5 x 1 0 . . . 4
0mmmm -5-10 5 10
6
8
10
12
2
4
Sn (mm)
________ pick up points
- - - - - - - - drop out points
Target size Usable range
mm mm
XS7E1A1D 8 x 8 x 1 0 . . . 8
XS7E1A1C 8 x 8 x 1 0 . . . 8
0
mm
mm
-1
5
-1
0
-
5
5
1
0
1
5
2
0
6
8
1
0
2
4
14
1
6
12
2
2
2
Sn
(
mm
)
________ pick up points
- - - - - - - - drop out points
Target size Usable range
mm mm
XS7C1A1D 18 x 18 x 1 0 . . . 12
XS7C1A1C 18 x 18 x 1 0 . . . 12
0mmmm -30 -20 -10 10 20 30 40-40
15
20
25
45
30
5
40
10
35
Sn (mm)
________ pick up points
- - - - - - - - drop out points
Target size Usable range
mm mm
XS7D1A1D 30 x 30 x 1 0 . . . 32
XS7D1A1C 30 x 30 x 1 0 . . . 32
Proximity Sensors
Tubular Inductive Sensing Curves
323
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Tubular Inductive Sensing Curves
Shielded
1ø 4 XS1
ø 5 (M5x0.5) XS1
2ø 6.5 XS1
ø 8 (M8x1) XS1, XS3
3ø 12 (M12x1)
XS1, XS3
1ø 18 (M18x1)
XS1, XS3
2ø 30 (M30x1.5)
XS1, XS3
Non-Shielded and Extended Range
1ø 8 (M8x1)
XS1, XS2, XS4
12 (M12x1)
XS1, XS2, XS4
1ø 18 (M18x1) XS1,
XS2, XS4
2ø 30 (M30x1.5) XS1,
XS2, XS4
Sn (mm)
mm 6 44
06 mm
22
11
2
0.5
33
1
3 2 1 123
________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
4 5 x 5 x 1 0 . . . 0.8
5 5 x 5 x 1 0 . . . 0.8
6.5 8 x 8 x 1 0 . . . 1.2
8 8 x 8 x 1 0 . . . 1.2
12 12 x 12 x 1 0 . . . 1.6
Sn (mm)
mm15 10 10
015 mm
22
1
5
2.5
7.5 5 2.5 2.5 5 7.5
1
10
8
15
________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
18 18 x 18 x 1 0 . . . 4
30 30 x 30 x 1 0 . . . 8
Sn (mm)
mm 6 44
06 mm
22
1
0.5
321 123
1
2
4
1
________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
8 8 x 8 x 1 0 . . . 2
12 12 x 12 x 1 0 . . . 3.2
Sn (mm)
mm 15 10 10
015 mm
22
1
2.5
7.5 5 2.5 2.5 5 7.5
1
5
15
10
8________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
18 24 x 24 x 1 0 . . . 6.4
30 45 x 45 x 1 0 . . . 12
Proximity Sensors
Block Type Inductive Sensing Curves
© 1997-2002 Schneider Electric All Rights Reserved
324 10/02
Proximity Sensors
Block Type Inductive Sensing Curves
1shielded, XSEC10
2shielded, XSG•02
3non-shielded,
XSG•04
1XSB•10
2XSB•25
1shielded, XS7
2 non-shielded, XS8
1fixed sensing
distance, XSD•40
2adjustable sensing
distance, XSD•60
Sn (mm)
mm 15 10 10
50 5 15 mm
11
10
5
4
2
33
22
________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
XSEC10 30 x 30 x 1 0 . . . 8
XSG•02 12 x 12 x 1 0 . . . 1.6
XSG•04 12 x 12 x 1 0 . . . 3.2
Sn (mm)
mm 30 20 20
10 010 30 mm
25
13
20
10
22
11________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
XSB•10 40 x 40 x 1 0 . . . 9
XSB•25 75 x 75 x 1 0 . . . 20
Sn (mm)
mm 30 20 20
10 010 30 mm
22
11
60
20
15
10
________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
XSC/XS7 45 x 45 x 1 0 . . . 12
XSC/XS8 60 x 60 x 1 0 . . . 16
Sn (mm)
mm 40 20 20
040 mm
22
11
30
22
40
60
20
________ pick up points
- - - - - - - - drop out points
Standard
targets
Size Usable range
mm mm
XSD•40 120 x 120 x 1 0 . . . 32
XSD•60 180 x 180 x 1 0 . . . 48
Proximity Sensors
Existing to New Substitution
325
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
8 mm Cylindrical
$
XS1N08PA349L2 XS608B1PAL10 XS1M12KP340D XS508B1NBM8
XS1M08DA210 XS508B1DAL2 XS1N08PA349S XS608B1PAM12 XS1M12KP340L1 XS508B1PAL5
XS1M08DA210D XS508B1DAM12 XS1N08PB340 XS508B1PBL2 XS1M12KP340L1 XS508B1PBL5
XS1M08DA210L1 XS508B1DAL5 XS1N08PB340D XS508B1PBM8 XS1M12KP340L1 XS508B1NAL5
XS1M08DA210L2 XS508B1DAL10 XS1N08PB340L1 XS508B1PBL5 XS1M12KP340L1 XS508B1NBL5
XS1M08DA210LD XS508B1DAL08M12 XS1N08PB340S XS508B1PBM8 XS1M12KP340L2 XS508B1PAL10
XS1M08DB210 XS508B1DBL2 XS1N08PB349 XS608B1PBL2 XS1M12KP340L2 XS508B1PBL10
XS1M08DB210D XS508B1DBM12 XS1N08PB349D XS608B1PBM12 XS1M12KP340L2 XS508B1NAL10
XS1M08DB210L1 XS508B1DBL5 XS1N08PB349L1 XS608B1PBL5 XS1M12KP340L2 XS508B1NBL10
XS1M08NA370 XS608B1NAL2 XS1N08PB349L2 XS608B1PBL10 XS1M12NA370 XS612B1NAL2
XS1M08NA370D XS608B1NAM12 XS1N08PB349S XS608B1PBM12 XS1M12NA370D XS612B1NAM12
XS1M08NA370L1 XS608B1NAL5 XS2M08NA340 XS608B1NAL2 XS1M12NA370L1 XS612B1NAL5
XS1M08NB370 XS608B1NBL2 XS2M08NC410 XS608B1NAL2 XS1M12NA370L2 XS612B1NAL10
XS1M08NB370D XS608B1NBM12 XS2M08NC410 XS608B1NBL2 XS1M12NA370S XS612B1NAM12
XS1M08NC410 XS508B1NAL2 XS2M08NC410D XS608B1NAM12 XS1M12NB370 XS612B1NBL2
XS1M08NC410 XS508B1NBL2 XS2M08NC410D XS608B1NBM12 XS1M12NB370D XS612B1NBM12
XS1M08NC410D XS508B1NAM8 XS2M08PC410 XS608B1PAL2 XS1M12PA370 XS612B1PAL2
XS1M08NC410D XS508B1NBM8 XS2M08PC410 XS608B1PBL2 XS1M12PA370D XS612B1PAM12
XS1M08PA370 XS608B1PAL2 XS2M08PC410D XS608B1PAM12 XS1M12PA370L1 XS612B1PAL5
XS1M08PA370D XS608B1PAM12 XS2M08PC410D XS608B1PBM12 XS1M12PA370L2 XS612B1PAL10
XS1M08PA370L1 XS608B1PAL5 XS2N08NA340 XS608B1NAL2 XS1M12PB370 XS612B1PBL2
XS1M08PA370L2 XS608B1PAL10 XS2N08NA340D XS608B1NAM8 XS1M12PB370D XS612B1PBM12
XS1M08PA370LD XS608B1PAL08M12 XS2N08NA340L1 XS608B1NAL5 XS1M12PB370L1 XS612B1PBL5
XS1M08PA370S XS608B1PAM12 XS2N08NA340S XS608B1NAM8 XS1N12NA340 XS512B1NAL2
XS1M08PB370 XS608B1PBL2 XS2N08NB340 XS608B1NBL2 XS1N12NA340D XS512B1NAM12
XS1M08PB370D XS608B1PBM12 XS2N08PA340 XS608B1PAL2 XS1N12NA340L1 XS512B1NAL5
XS1M08PB370L1 XS608B1PBL5 XS2N08PA340D XS608B1PAM8 XS1N12NA349 XS612B1NAL2
XS1M08PB370L2 XS608B1PBL10 XS2N08PA340L1 XS608B1PAL5 XS1N12NA349D XS612B1NAM12
XS1M08PC410 XS508B1PAL2 XS2N08PA340L2 XS608B1PAL10 XS1N12NA349L1 XS612B1NAL5
XS1M08PC410 XS508B1PBL2 XS2N08PA340S XS608B1PAM8 XS1N12NA349L2 XS612B1NAL10
XS1M08PC410D XS508B1PAM8 XS2N08PB340 XS608B1PBL2 XS1N12NB340 XS512B1NBL2
XS1M08PC410D XS508B1PBM8 XS2N08PB340D XS608B1PBM8 XS1N12NB340D XS512B1NBM12
XS1N08NA340D XS508B1NAM8 XS2N08PB340S XS608B1PBM8 XS1N12NB349 XS612B1NBL2
XS1N08NA340L1 XS508B1NAL5 XS3P08NA340 XS508B1NAL2 XS1N12NB349D XS612B1NBM12
XS1N08NA340L2 XS508B1NAL10 XS3P08NA340D XS508B1NAM8 XS1N12NB349L2 XS612B1NBL10
XS1N08NA340S XS508B1NAM8 XS3P08NA370 XS608B1NAL2 XS1N12NC410 XS512B1NAL2
XS1N08NA349 XS608B1NAL2 XS3P08PA340 XS508B1PAL2 XS1N12NC410 XS512B1NBL2
XS1N08NA349D XS608B1NAM12 XS3P08PA340D XS508B1PAM12 XS1N12NC410D XS512B1NBM12
XS1N08NA349L1 XS608B1NAL5 XS3P08PA340L1 XS508B1PAL5 XS1N12NC410D XS512B1NAM12
XS1N08NA349S XS608B1NAM12 XS3P08PA370 XS608B1PAL2 XS1N12NC410L1 XS512B1NAL5
XS1N08NB340 XS508B1NBL2 12 mm Cylindrical
$
XS1N12NC410L1 XS512B1NBL5
XS1N08NB340D XS508B1NBM8 XS1M12DA210 XS512B1DAL2 XS1N12PA340 XS512B1PAL2
XS1N08NB340S XS508B1NBM8 XS1M12DA210D XS512B1DAM12 XS1N12PA340D XS512B1PAM12
XS1N08NB349 XS608B1NBL2 XS1M12DA210L1 XS512B1DAL5 XS1N12PA340L1 XS512B1PAL5
XS1N08NB349D XS608B1NBM12 XS1M12DA210L2 XS512B1DAL10 XS1N12PA340L2 XS512B1PAL10
XS1N08NB349S XS608B1NBM12 XS1M12DB210 XS512B1DBL2 XS1N12PA340S XS512B1PAM12
XS1N08PA340 XS508B1PAL2 XS1M12DB210D XS512B1DBM12 XS1N12PA349 XS612B1PAL2
XS1N08PA340D XS508B1PAM8 XS1M12DB210L1 XS512B1DBL5 XS1N12PA349D XS612B1PAM12
XS1N08PA340L1 XS508B1PAL5 XS1M12KP340 XS508B1PAL2 XS1N12PA349L1 XS612B1PAL5
XS1N08PA340L2 XS508B1PAL10 XS1M12KP340 XS508B1PBL2 XS1N12PA349L2 XS612B1PAL10
XS1N08PA340LD XS508B1PAL08M12 XS1M12KP340 XS508B1NAL2 XS1N12PA349S XS612B1PAM12
XS1N08PA340S XS508B1PAM8 XS1M12KP340 XS508B1NBL2 XS1N12PB340 XS512B1PBL2
XS1N08PA349 XS608B1PAL2 XS1M12KP340D XS508B1PAM8 XS1N12PB340D XS512B1PBM12
XS1N08PA349D XS608B1PAM12 XS1M12KP340D XS508B1PBM8 XS1N12PB349 XS612B1PBL2
XS1N08PA349L1 XS608B1PAL5 XS1M12KP340D XS508B1NAM8 XS1N12PB349D XS612B1PBM12
Proximity Sensors
Existing to New Substitution
© 1997-2002 Schneider Electric All Rights Reserved
326 10/02
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
XS1N12PB349L1 XS612B1PBL5 XS2N12PA340 XS612B1PAL2 XS1M18NA370C XS618B1NAM12
XS1N12PB349L2 XS612B1PBL10 XS2N12PA340D XS612B1PAM12 XS1M18NA370D XS618B1NAM12
XS1N12PB349S XS612B1PBM12 XS2N12PA340L1 XS612B1PAL5 XS1M18NA370L1 XS618B1NAL5
XS1N12PC410 XS512B1PAL2 XS2N12PA340L2 XS612B1PAL10 XS1M18NA370L2 XS618B1NAL10
XS1N12PC410 XS512B1PBL2 XS2N12PB340 XS612B1PBL2 XS1M18NB370 XS618B1NBL2
XS1N12PC410D XS512B1PAM12 XS2N12PB340D XS612B1PBM12 XS1M18NB370C XS618B1NBM12
XS1N12PC410D XS512B1PBM12 XS2N12PC410 XS612B1PAL2 XS1M18NB370D XS618B1NBM12
XS1N12PC410L1 XS512B1PAL5 XS2N12PC410 XS612B1PBL2 XS1M18NB370L1 XS618B1NBL5
XS1N12PC410L1 XS512B1PBL5 XS2N12PC410D XS612B1PAM12 XS1M18NB370L2 XS618B1NBL10
XS1N12PC410L2 XS512B1PAL10 XS2N12PC410D XS612B1PBM12 XS1M18PA370 XS618B1PAL2
XS1N12PC410L2 XS512B1PBL10 XS2N12PC410L1 XS612B1PAL5 XS1M18PA370A XS618B1PAM12
XS1N12PC419D XS612B1PAM12 XS2N12PC410L1 XS612B1PBL5 XS1M18PA370B XS618B1PAM12
XS1N12PC419D XS612B1PBM12 XS2N12PC410L2 XS612B1PAL10 XS1M18PA370C XS618B1PAM12
XS2M12KP340 XS612B1PAL2 XS2N12PC410L2 XS612B1PBL10 XS1M18PA370D XS618B1PAM12
XS2M12KP340 XS612B1PBL2 XS3P12NA340 XS512B1NAL2 XS1M18PA370E XS618B1PAM12
XS2M12KP340 XS612B1NAL2 XS3P12NA340D XS512B1NAM12 XS1M18PA370G XS618B1PAM12
XS2M12KP340 XS612B1NBL2 XS3P12NA370 XS612B1NAL2 XS1M18PA370L1 XS618B1PAL5
XS2M12KP340D XS612B1PAM12 XS3P12PA340 XS512B1PAL2 XS1M18PA370L2 XS618B1PAL10
XS2M12KP340D XS612B1PBM12 XS3P12PA340D XS512B1PAM12 XS1M18PA370T XS618B1PAL2T
XS2M12KP340D XS612B1NAM12 XS3P12PA340L1 XS512B1PAL5 XS1M18PB370 XS618B1PBL2
XS2M12KP340D XS612B1NBM12 XS3P12PA370 XS612B1PAL2 XS1M18PB370A XS618B1PBM12
XS2M12KP340L1 XS612B1PAL5 XS3P12PA370L1 XS612B1PAL5 XS1M18PB370B XS618B1PBM12
XS2M12KP340L1 XS612B1PBL5 18 mm Cylindrical
$
XS1M18PB370C XS618B1PBM12
XS2M12KP340L1 XS612B1NAL5 XS1M18DA210 XS518B1DAL2 XS1M18PB370D XS618B1PBM12
XS2M12KP340L1 XS612B1NBL5 XS1M18DA210B XS518B1DAM12 XS1M18PB370G XS618B1PBM12
XS2M12KP340L2 XS612B1PAL10 XS1M18DA210C XS518B1DAM12 XS1M18PB370L1 XS618B1PAL5
XS2M12KP340L2 XS612B1PBL10 XS1M18DA210D XS518B1DAM12 XS1M18PB370L2 XS618B1PAL10
XS2M12KP340L2 XS612B1NAL10 XS1M18DA210G XS518B1DAM12 XS1N18NA340 XS518B1NAL2
XS2M12KP340L2 XS612B1NBL10 XS1M18DA210L1 XS518B1DAL5 XS1N18NA340D XS518B1NAM12
XS2M12NA370 XS612B1NAL2 XS1M18DA210L2 XS518B1DAL10 XS1N18NA340L1 XS518B1NAL5
XS2M12NA370D XS612B1NAM12 XS1M18DA210LD XS518B1DAL08M12 XS1N18NA340L2 XS618B1NAL10
XS2M12NA370L1 XS612B1NAL5 XS1M18DA214D XS518B1CAM12 XS1N18NA349 XS618B1NAL2
XS2M12NB370 XS612B1NBL2 XS1M18DA214LD XS518B1CAL08M12 XS1N18NA349D XS618B1NAM12
XS2M12NB370D XS612B1NBM12 XS1M18DB210 XS518B1DBL2 XS1N18NA349L1 XS618B1NAL5
XS2M12PA370 XS612B1PAL2 XS1M18DB210B XS518B1DBM12 XS1N18NB340 XS518B1NBL2
XS2M12PA370D XS612B1PAM12 XS1M18DB210D XS518B1DBM12 XS1N18NB340D XS518B1NBM12
XS2M12PA370L1 XS612B1PAL5 XS1M18KP340 XS518B1PAL2 XS1N18NB349 XS618B1NBL2
XS2M12PA370L2 XS612B1PAL10 XS1M18KP340 XS518B1PBL2 XS1N18NB349D XS618B1NBM12
XS2M12PB370 XS612B1PBL2 XS1M18KP340 XS518B1NAL2 XS1N18NC410 XS518B1NAL2
XS2M12PB370D XS612B1PBM12 XS1M18KP340 XS518B1NBL2 XS1N18NC410 XS518B1NBL2
XS2M12PB370S XS612B1PBM12 XS1M18KP340D XS518B1PAM12 XS1N18NC410D XS518B1NAM12
XS2M12PC410D XS612B1PAM12 XS1M18KP340D XS518B1PBM12 XS1N18NC410D XS518B1NBM12
XS2M12PC410D XS612B1PBM12 XS1M18KP340D XS518B1NAM12 XS1N18NC410L1 XS518B1NAL5
XS2N12NA340 XS612B1NAL2 XS1M18KP340D XS518B1NBM12 XS1N18NC410L1 XS518B1NBL5
XS2N12NA340D XS612B1NAM12 XS1M18KP340L1 XS518B1PAL5 XS1N18PA340 XS518B1PAL2
XS2N12NA340L1 XS612B1NAL5 XS1M18KP340L1 XS518B1PBL5 XS1N18PA340D XS518B1PAM12
XS2N12NA340L2 XS612B1NAL10 XS1M18KP340L1 XS518B1NAL5 XS1N18PA340L1 XS518B1PAL5
XS2N12NB340 XS612B1NBL2 XS1M18KP340L1 XS518B1NBL5 XS1N18PA340L2 XS518B1PAL10
XS2N12NB340D XS612B1NBM12 XS1M18KP340L2 XS518B1PAL10 XS1N18PA349 XS618B1PAL2
XS2N12NC410 XS612B1NAL2 XS1M18KP340L2 XS518B1PBL10 XS1N18PA349D XS618B1PAM12
XS2N12NC410 XS612B1NBL2 XS1M18KP340L2 XS518B1NAL10 XS1N18PA349L1 XS618B1PAL5
XS2N12NC410D XS612B1NAM12 XS1M18KP340L2 XS518B1NBL10 XS1N18PA349L2 XS618B1PAL10
XS2N12NC410D XS612B1NBM12 XS1M18NA370 XS618B1NAL2 XS1N18PA349S XS618B1PAM12
XS2N12NC410L1 XS612B1NAL5 XS1M18NA370A XS618B1NAM12 XS1N18PB340 XS518B1PBL2
XS2N12NC410L1 XS612B1NBL5 XS1M18NA370B XS618B1NAM12 XS1N18PB340D XS518B1PBM12
Proximity Sensors
Existing to New Substitution
327
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
XS1N18PB340L2 XS518B1PBL10 XS2N18NC410 XS618B1NBL2 XS1M30NA370 XS630B1NAL2
XS1N18PB349 XS618B1PBL2 XS2N18NC410D XS618B1NAM12 XS1M30NA370B XS630B1NAM12
XS1N18PB349D XS618B1PBM12 XS2N18NC410D XS618B1NBM12 XS1M30NA370C XS630B1NAM12
XS1N18PB349L1 XS618B1PBL5 XS2N18PA340 XS618B1PAL2 XS1M30NA370D XS630B1NAM12
XS1N18PB349L2 XS618B1PBL10 XS2N18PA340D XS618B1PAM12 XS1M30NA370G XS630B1NAM12
XS1N18PB349S XS618B1PBM12 XS2N18PA340L1 XS618B1PAL5 XS1M30NA370L1 XS630B1NAL5
XS1N18PC410 XS518B1PAL2 XS2N18PA340L2 XS618B1PAL10 XS1M30NA370L2 XS630B1NAL10
XS1N18PC410 XS518B1PBL2 XS2N18PB340 XS618B1PBL2 XS1M30NA370T XS630B1NAL2T
XS1N18PC410D XS518B1PAM12 XS2N18PB340D XS618B1PBM12 XS1M30NB370 XS630B1NBL2
XS1N18PC410D XS518B1PBM12 XS2N18PC410 XS618B1PAL2 XS1M30NB370B XS630B1NBM12
XS1N18PC410L1 XS518B1PAL5 XS2N18PC410 XS618B1PBL2 XS1M30NB370D XS630B1NBM12
XS1N18PC410L1 XS518B1PBL5 XS2N18PC410D XS618B1PAM12 XS1M30PA349C XS630B1PAM12
XS1N18PC410P XS518B1PAL10 XS2N18PC410D XS618B1PBM12 XS1M30PA349D XS630B1PAM12
XS1N18PC410P XS518B1PBL10 XS2N18PC410L1 XS618B1PAL5 XS1M30PA370 XS630B1PAL2
XS2M18KP340 XS618B1PAL2 XS2N18PC410L1 XS618B1PBL5 XS1M30PA370A XS630B1PAM12
XS2M18KP340 XS618B1PBL2 XS3P18NA340 XS518B1NAL2 XS1M30PA370B XS630B1PAM12
XS2M18KP340 XS618B1NAL2 XS3P18NA340D XS518B1NAM12 XS1M30PA370C XS630B1PAM12
XS2M18KP340 XS618B1NBL2 XS3P18NA370 XS618B1NAL2 XS1M30PA370D XS630B1PAM12
XS2M18KP340D XS618B1PAM12 XS3P18PA340 XS518B1PAL2 XS1M30PA370G XS630B1PAM12
XS2M18KP340D XS618B1PBM12 XS3P18PA340D XS518B1PAM12 XS1M30PA370L1 XS630B1PAL5
XS2M18KP340D XS618B1NAM12 XS3P18PA340L1 XS518B1PAL5 XS1M30PA370L2 XS630B1PAL10
XS2M18KP340D XS618B1NBM12 XS3P18PA370 XS618B1PAL2 XS1M30PA370T XS630B1PAL2T
XS2M18KP340L1 XS618B1PAL5 30 mm Cylindrical
$
XS1M30PB370 XS630B1PBL2
XS2M18KP340L1 XS618B1PBL5 XS1M30DA210 XS530B1DAL2 XS1M30PB370B XS630B1PBM12
XS2M18KP340L1 XS618B1NAL5 XS1M30DA210B XS530B1DAM12 XS1M30PB370C XS630B1PBM12
XS2M18KP340L1 XS618B1NBL5 XS1M30DA210C XS530B1DAM12 XS1M30PB370D XS630B1PBM12
XS2M18KP340L2 XS618B1PAL10 XS1M30DA210D XS530B1DAM12 XS1M30PB370G XS630B1PBM12
XS2M18KP340L2 XS618B1PBL10 XS1M30DA210G XS530B1DAM12 XS1M30PB370L1 XS630B1PBL5
XS2M18KP340L2 XS618B1NAL10 XS1M30DA210L1 XS530B1DAL5 XS1M30PB370L2 XS630B1PBL10
XS2M18KP340L2 XS618B1NBL10 XS1M30DA210L2 XS530B1DAL10 XS1N30NA340 XS530B1NAL2
XS2M18NA370 XS618B1NAL2 XS1M30DA210LA XS530B1DAM12 XS1N30NA340D XS530B1NAM12
XS2M18NA370C XS618B1NAM12 XS1M30DA210LD XS530B1DAM12 XS1N30NA349 XS630B1NAL2
XS2M18NA370D XS618B1NAM12 XS1M30DB210 XS530B1DBL2 XS1N30NA349D XS630B1NAM12
XS2M18NA370L1 XS618B1NAL5 XS1M30DB210B XS530B1DBM12 XS1N30NA349L1 XS630B1NAL5
XS2M18NA370L2 XS618B1NAL10 XS1M30DB210D XS530B1DBM12 XS1N30NA349L2 XS630B1NAL10
XS2M18NA370T XS618B1NAM12T XS1M30KP340 XS530B1PAL2 XS1N30NB340 XS530B1NBL2
XS2M18NB370 XS618B1NBL2 XS1M30KP340 XS530B1PBL2 XS1N30NB349 XS630B1NBL2
XS2M18NB370D XS618B1NBM12 XS1M30KP340 XS530B1NAL2 XS1N30NB349D XS630B1NBM12
XS2M18PA370 XS618B1PAL2 XS1M30KP340 XS530B1NBL2 XS1N30NC410 XS530B1NAL2
XS2M18PA370C XS618B1PAM12 XS1M30KP340D XS530B1PAM12 XS1N30NC410 XS530B1NBL2
XS2M18PA370D XS618B1PAM12 XS1M30KP340D XS308B1PBM12 XS1N30NC410D XS530B1NAM12
XS2M18PA370G XS618B1PAM12 XS1M30KP340D XS530B1NAM12 XS1N30NC410D XS530B1NBM12
XS2M18PA370L1 XS618B1PAL5 XS1M30KP340D XS530B1NBM12 XS1N30PA340 XS530B1PAL2
XS2M18PA370L2 XS618B1PAL10 XS1M30KP340L1 XS530B1PAL5 XS1N30PA340D XS530B1PAM12
XS2M18PA370T XS618B1PAL2T XS1M30KP340L1 XS530B1PBL5 XS1N30PA340L1 XS530B1PAL5
XS2M18PB370 XS618B1PBL2 XS1M30KP340L1 XS530B1NAL5 XS1N30PA340L2 XS530B1PAL10
XS2M18PB370C XS618B1PBM12 XS1M30KP340L1 XS530B1NBL6 XS1N30PA349 XS630B1PAL2
XS2M18PB370D XS618B1PBM12 XS1M30KP340L2 XS530B1PAL10 XS1N30PA349D XS630B1PAM12
XS2M18PB370G XS618B1PBM12 XS1M30KP340L2 XS530B1PBL10 XS1N30PA349L1 XS630B1PAL5
XS2M18PB370L1 XS618B1PBL5 XS1M30KP340L2 XS530B1NAL10 XS1N30PA349L2 XS630B1PAL10
XS2M18PB370L2 XS618B1PBL10 XS1M30KP340L2 XS530B1NBL10 XS1N30PA349S XS630B1PAM12
XS2N18NA340 XS618B1NAL2 XS1M30KP370 XS630B1PAL2 XS1N30PB340 XS530B1PBL2
XS2N18NA340D XS618B1NAM12 XS1M30KP370 XS630B1PBL2 XS1N30PB340D XS530B1PBM12
XS2N18NA340L1 XS618B1NAL5 XS1M30KP370 XS630B1NAL2 XS1N30PB349 XS630B1PBL2
XS2N18NC410 XS618B1NAL2 XS1M30KP370 XS630B1NBL2 XS1N30PB349D XS630B1PBM12
Proximity Sensors
Existing to New Substitution
© 1997-2002 Schneider Electric All Rights Reserved
328 10/02
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
XS1N30PB349L1 XS630B1PBL5 XS2N30PB340D XS630B1PBM12 XS1M18MA230B XS618B1MAU20
XS1N30PB349L2 XS630B1PBL10 XS2N30PC410 XS630B1PAL2 XS1M18MA230C XS618B1MAU20
XS1N30PC410 XS530B1PAL2 XS2N30PC410 XS630B1PBL2 XS1M18MA230G XS618B1MAU20
XS1N30PC410 XS530B1PBL2 XS2N30PC410D XS630B1PAM12 XS1M18MA230K XS618B1MAU20
XS1N30PC410D XS530B1PAM12 XS2N30PC410D XS630B1PBM12 XS1M18MA230L1 XS618B1MAL5
XS1N30PC410D XS530B1PBM12 XS2N30PC410L1 XS630B1PAL5 XS1M18MA230L2 XS618B1MAL10
XS1N30PC410L1 XS530B1PAL5 XS2N30PC410L1 XS630B1PBL5 XS1M18MA230T XS618B1MAL2T
XS1N30PC410L1 XS530B1PBL5 XS3P30NA340 XS530B1NAL2 XS1M18MA239 XS618B1MAL2
XS1N30PC410L2 XS530B1PAL10 XS3P30NA340D XS530B1NAM12 XS1M18MA239A XS618B1MAU20
XS1N30PC410L2 XS530B1PBL10 XS3P30NA370 XS630B1NAL2 XS1M18MA239K XS618B1MAU20
XS2M30KP340 XS630B1PAL2 XS3P30PA340 XS530B1PAL2 XS1M18MA250 XS618B1MAL2
XS2M30KP340 XS630B1PAL2 XS3P30PA340D XS530B1PAM12 XS1M18MA250A XS618B1MAU20
XS2M30KP340 XS630B1PAL2 XS3P30PA340L1 XS530B1PAL5 XS1M18MA250H4 XS618B1MAL2
XS2M30KP340 XS630B1PAL2 XS3P30PA340L2 XS530B1PAL10 XS1M18MA250K XS618B1MAU20
XS2M30KP340D XS630B1PAM12 XS3P30PA370 XS630B1PAL2 XS1M18MA250KH4 XS618B1MAU20
XS2M30KP340D XS630B1PAM12 XS3P30PA370L1 XS630B1PAL5 XS1M18MA250L1 XS618B1MAL5
XS2M30KP340D XS630B1PAM12 XS3P30PA370L2 XS630B1PAL10 XS1M18MA250L2 XS618B1MAL10
XS2M30KP340D XS630B1PAM12 12 mm Cylindrical
"
XS1M18MB230 XS618B1MBL2
XS2M30KP340L1 XS630B1PAL5 XS1M12MA230 XS612B1MAL2 XS1M18MB230A XS618B1MBU20
XS2M30KP340L1 XS630B1PAL5 XS1M12MA230K XS612B1MAU20 XS1M18MB230B XS618B1MBU20
XS2M30KP340L1 XS630B1PAL5 XS1M12MA230L1 XS612B1MAL5 XS1M18MB230C XS618B1MBU20
XS2M30KP340L1 XS630B1PAL5 XS1M12MA230L2 XS612B1MAL10 XS1M18MB230G XS618B1MBU20
XS2M30KP340L2 XS630B1PAL10 XS1M12MA239 XS612B1MAL2 XS1M18MB230K XS618B1MBU20
XS2M30KP340L2 XS630B1PAL10 XS1M12MA239K XS612B1MAU20 XS1M18MB230L1 XS618B1MBL5
XS2M30KP340L2 XS630B1PAL10 XS1M12MA250 XS612B1MAL2 XS1M18MB230L2 XS618B1MBL10
XS2M30KP340L2 XS630B1PAL10 XS1M12MA250K XS612B1MAU20 XS1M18MB250 XS618B1MBL2
XS2M30NA370 XS630B1NAL2 XS1M12MA250L1 XS612B1MAL5 XS1M18MB250A XS618B1MBU20
XS2M30NA370D XS630B1NAM12 XS1M12MA250L2 XS612B1MAL10 XS1M18MB250K XS618B1MBU20
XS2M30NA370L1 XS630B1NAL5 XS1M12MB230 XS612B1MBL2 XS1M18MB250L1 XS618B1MBL5
XS2M30NB370 XS630B1NBL2 XS1M12MB230K XS612B1MBU20 XS1M18MB250L2 XS618B1MBL10
XS2M30NB370D XS630B1NBM12 XS1M12MB230L1 XS612B1MBL5 XS2M18DA210L2 XS612B1MAL10
XS2M30PA370 XS630B1PAL2 XS1M12MB230L2 XS612B1MBL10 XS2M18MA230 XS618B1MAL2
XS2M30PA370C XS630B1PAM12 XS1M12MB250 XS612B1MBL2 XS2M18MA230A XS618B1MAU20
XS2M30PA370D XS630B1PAM12 XS2M12MA230 XS612B1MAL2 XS2M18MA230C XS618B1MAU20
XS2M30PA370G XS630B1PAM12 XS2M12MA230K XS612B1MAU20 XS2M18MA230G XS618B1MAU20
XS2M30PA370L1 XS630B1PAL5 XS2M12MA230L1 XS612B1MAL5 XS2M18MA230K XS618B1MAU20
XS2M30PA370L2 XS630B1PAL10 XS2M12MA230L2 XS612B1MAL10 XS2M18MA230L1 XS618B1MAL5
XS2M30PA370T XS630B1PAL2T XS2M12MA250 XS612B1MAL2 XS2M18MA230L2 XS618B1MAL10
XS2M30PB370 XS630B1PBL2 XS2M12MA250K XS612B1MAU20 XS2M18MA230T XS618B1MAL2T
XS2M30PB370C XS630B1PBM12 XS2M12MA250L1 XS612B1MAL5 XS2M18MA250 XS618B1MAL2
XS2M30PB370D XS630B1PBM12 XS2M12MA250L2 XS612B1MAL10 XS2M18MA250A XS618B1MAU20
XS2M30PB370L1 XS630B1PBL5 XS2M12MB230 XS612B1MBL2 XS2M18MA250K XS618B1MAU20
XS2M30PB370L2 XS630B1PBL10 XS2M12MB230K XS612B1MBU20 XS2M18MA250L1 XS618B1MAL5
XS2N30NA340 XS630B1NAL2 XS2M12MB230L1 XS612B1MBL5 XS2M18MA250L2 XS618B1MAL10
XS2N30NA340D XS630B1NAM12 XS2M12MB230L2 XS612B1MBL10 XS2M18MB230 XS618B1MBL2
XS2N30NB340 XS630B1NBL2 XS2M12MB250 XS612B1MBL2 XS2M18MB230A XS618B1MBU20
XS2N30NC410 XS630B1NAL2 XS2M12MB250L1 XS612B1MBL5 XS2M18MB230C XS618B1MBU20
XS2N30NC410 XS630B1NBL2 XS2M12MB250L2 XS612B1MBL10 XS2M18MB230G XS618B1MBU20
XS2N30NC410D XS630B1NAM12 XS3P12MA230 XS612B1MAL2 XS2M18MB230K XS618B1MBU20
XS2N30NC410D XS630B1NBM12 XS3P12MA230K XS612B1MAU20 XS2M18MB230L1 XS618B1MBL5
XS2N30PA340 XS630B1PAL2 XS3P12MA230L1 XS612B1MAL5 XS2M18MB230L2 XS618B1MBL10
XS2N30PA340D XS630B1PAM12 XS3P12MB230 XS612B1MBL2 XS2M18MB250 XS618B1MBL2
XS2N30PA340L1 XS630B1PAL5 18 mm Cylindrical
"
XS2M18MB250A XS618B1MBU20
XS2N30PA340L2 XS630B1PAL10 XS1M18MA230 XS618B1MAL2 XS2M18MB250K XS618B1MBU20
XS2N30PB340 XS630B1PBL2 XS1M18MA230A XS618B1MAU20 XS2M18MB250L1 XS618B1MBL5
Proximity Sensors
Existing to New Substitution
329
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
XS2M18MB250L2 XS618B1MBL10 XS2M30MB230 XS630B1MBL2 XS7C40DP210TF XS7C1A1DAM8 + XSZBC10
XS3P18MA230 XS618B1MAL2 XS2M30MB230A XS630B1MBU20 XS7C40DP210TF XS7C1A1DBM8 + XSZBC10
XS3P18MA230A XS618B1MAU20 XS2M30MB230C XS630B1MBU20 XS7C40KPM40 XS9C11MPAM8 + XSZBC10
XS3P18MA230K XS618B1MAU20 XS2M30MB230G XS630B1MBU20 XS7C40KPM40 XS9C11MPBM8 + XSZBC10
XS3P18MA230L1 XS618B1MAL5 XS2M30MB230K XS630B1MBU20 XS7C40KPM40 XS9C11MNAM8 + XSZBC10
XS3P18MA230L2 XS618B1MAL10 XS2M30MB230L1 XS630B1MBL5 XS7C40KPM40 XS9C11MPBM8 + XSZBC10
XS3P18MB230 XS618B1MBL2 XS2M30MB230L2 XS630B1MBL10 XS7C40KPM40H29 XS9C11MPAM8 + XSZBC10
XS3P18MB230A XS618B1MBU20 XS2M30MB250 XS630B1MBL2 XS7C40KPM40H29 XS9C11MPBM8 + XSZBC10
XS3P18MB230K XS618B1MBU20 XS2M30MB250K XS630B1MBU20 XS7C40KPM40H29 XS9C11MNAM8 + XSZBC10
XS3P18MB230L1 XS618B1MBL5 XS2M30MB250L1 XS630B1MBL5 XS7C40KPM40H29 XS9C11MPBM8 + XSZBC10
30 mm Cylindrical
"
XS3P30MA230 XS630B1MAL2 XS7C40KPM40H7 XS9C11MPAM8 + XSZBC10
XS1M30MA230 XS630B1MAL2 XS3P30MA230A XS630B1MAU20 XS7C40KPM40H7 XS9C11MPBM8 + XSZBC10
XS1M30MA230A XS630B1MAU20 XS3P30MA230K XS630B1MAU20 XS7C40KPM40H7 XS9C11MNAM8 + XSZBC10
XS1M30MA230B XS630B1MAU20 XS3P30MA230L1 XS630B1MAL5 XS7C40KPM40H7 XS9C11MPBM8 + XSZBC10
XS1M30MA230C XS630B1MAU20 XS3P30MA230L2 XS630B1MAL10 XS7C40NC440 XS7C1A1NAM8 + XSZBC10
XS1M30MA230G XS630B1MAU20 XS3P30MB230 XS630B1MBL2 XS7C40NC440 XS7C1A1NBM8 + XSZBC10
XS1M30MA230K XS630B1MAU20 XS3P30MB230A XS630B1MBU20 XS7C40NC440D XS7C1A1NAM8 + XSZBC10
XS1M30MA230L1 XS630B1MAL5 XS3P30MB230K XS630B1MBU20 XS7C40NC440D XS7C1A1NBM8 + XSZBC10
XS1M30MA230L2 XS630B1MAL10 XS3P30MB230L1 XS630B1MBL5 XS7C40NC440H29 XS7C1A1NAM8 + XSZBC10
XS1M30MA230T XS630B1MAL2T XSC Rectangular
"
XS7C40NC440H29 XS7C1A1NBM8 + XSZBC10
XS1M30MA239 XS630B1MAL2 XSCA150549 XS8C1A1MAL01U20 + XSZBC10 XS7C40NC449 XS8C1A1NAM8 + XSZBC10
XS1M30MA239A XS630B1MAU20 XSCA150549 XS8C1A1MBL01U20 + XSZBC10 XS7C40NC449 XS8C1A1NBM8 + XSZBC10
XS1M30MA250 XS630B1MAL2 XSD Rectangular
"
XS7C40NC449H29 XS8C1A1NAM8 + XSZBC10
XS1M30MA250A XS630B1MAU20 XSDA400519 XS8D1A1MAU20 + XSZBD10 XS7C40NC449H29 XS8C1A1NBM8 + XSZBC10
XS1M30MA250AH4 XS630B1MAU20 XSDA400519 XS8D1A1MBU20 + XSZBD10 XS7C40PC440 XS7C1A1PAM8 + XSZBC10
XS1M30MA250H4 XS630B1MAL2 XSDA400519H7 XS8D1A1MAU20 + XSZBD10 XS7C40PC440 XS7C1A1PBM8 + XSZBC10
XS1M30MA250K XS630B1MAU20 XSDA400519H7 XS8D1A1MBU20 + XSZBD10 XS7C40PC440D XS7C1A1PAM8 + XSZBC10
XS1M30MA250KH4 XS630B1MAU20 XSDA500519 XS8D1A1MAU20 + XSZBD10 XS7C40PC440D XS7C1A1PBM8 + XSZBC10
XS1M30MA250L1 XS630B1MAL5 XSDA500519 XS8D1A1MBU20 + XSZBD10 XS7C40PC440H29 XS7C1A1PAM8 + XSZBC10
XS1M30MA250L2 XS630B1MAL10 XSDA500519H7 XS8D1A1MAU20 + XSZBD10 XS7C40PC440H29 XS7C1A1PBM8 + XSZBC10
XS1M30MB230 XS630B1MBL2 XSDA500519H7 XS8D1A1MBU20 + XSZBD10 XS7C40PC440H7 XS7C1A1PAM8 + XSZBC10
XS1M30MB230A XS630B1MBU20 XSDA505539H4 XS8D1A1MAU20 + XSZBD10 XS7C40PC440H7 XS7C1A1PBM8 + XSZBC10
XS1M30MB230B XS630B1MBU20 XSDA505539H4 XS8D1A1MBU20 + XSZBD10 XS7C40PC449 XS8C1A1PAM8 + XSZBC10
XS1M30MB230C XS630B1MBU20 XSDA600519 XS8D1A1MAU20 + XSZBD10 XS7C40PC449 XS8C1A1PBM8 + XSZBC10
XS1M30MB230G XS630B1MBU20 XSDA600519 XS8D1A1MBU20 + XSZBD10 XS7C40PC449H29 XS8C1A1PAM8 + XSZBC10
XS1M30MB230K XS630B1MBU20 XSDA600519H7 XS8D1A1MAU20 + XSZBD10 XS7C40PC449H29 XS8C1A1PBM8 + XSZBC10
XS1M30MB230L1 XS630B1MBL5 XSDA600519H7 XS8D1A1MBU20 + XSZBD10 XS7C40PC449H7 XS8C1A1PAM8 + XSZBC10
XS1M30MB230L2 XS630B1MBL10 XSDM500538 XS8D1A1MAU20 + XSZBD10 XS7C40PC449H7 XS8C1A1PBM8 + XSZBC10
XS1M30MB250 XS630B1MBL2 XSDM500538 XS8D1A1MBU20 + XSZBD10 XS7T2DA210 XS7E1A1DAL2 + XSZBE10
XS1M30MB250A XS630B1MBU20 XSDM600539 XS8D1A1MAU20 + XSZBD10 XS7T2DA214LD XS7E1A1CAL08M12 + XSZBE10
XS1M30MB250K XS630B1MBU20 XSDM600539 XS8D1A1MBU20 + XSZBD10 XS7T2DA214LD01 XS7E1A1CAL01M12 + XSZBE10
XS1M30MB250L1 XS630B1MBL5 XSDM600539H7 XS8D1A1MAU20 + XSZBD10 XS7T2NC440 XS7E1A1NAL2 + XSZBE10
XS1M30MB250L2 XS630B1MBL10 XSDM600539H7 XS8D1A1MBU20 + XSZBD10 XS7T2NC440 XS7E1A1NBL2 + XSZBE10
XS2M30MA230 XS630B1MAL2 XS7 Rectangular
$
XS7T2NC440LD XS7E1A1NAL01M12 + XSZBE10
XS2M30MA230A XS630B1MAU20 XS7C40DA210 XS7C1A1DAM8 + XSZBC10 XS7T2NC440LD XS7E1A1NBL01M12 + XSZBE10
XS2M30MA230C XS630B1MAU20 XS7C40DA210A XS7C1A1DAM8 + XSZBC10 XS7T2PC440 XS7E1A1PAL2 + XSZBE10
XS2M30MA230G XS630B1MAU20 XS7C40DA214D XS7C1A1CAL08M12 + XSZBC10 XS7T2PC440 XS7E1A1PBL2 + XSZBE10
XS2M30MA230K XS630B1MAU20 XS7C40DP210 XS7C1A1DAM8 + XSZBC10 XS7T2PC440LD XS7E1A1PAL08M12 + XSZBE10
XS2M30MA230L1 XS630B1MAL5 XS7C40DP210 XS7C1A1DBM8 + XSZBC10 XS7T2PC440LD XS7E1A1PBL08M12 + XSZBE10
XS2M30MA230L2 XS630B1MAL10 XS7C40DP210H29 XS7C1A1DAM8 + XSZBC10 XS7T4DA210 XS7C1A1DAL2 + XSZBC10
XS2M30MA230T XS630B1MAL2T XS7C40DP210H29 XS7C1A1DBM8 + XSZBC10 XS7T4DA214LD XS7C1A1CAL08M12 + XSZBC10
XS2M30MA250 XS630B1MAL2 XS7C40DP210H7 XS7C1A1DAM8 + XSZBC10 XS7T4DA214LD01 XS7C1A1CAL01M12 + XSZBC10
XS2M30MA250K XS630B1MAU20 XS7C40DP210H7 XS7C1A1DBM8 + XSZBC10 XS7T4NC440 XS7C1A1NAL2 + XSZBC10
XS2M30MA250L1 XS630B1MAL5 XS7C40DP210TT XS7C1A1DAM8 + XSZBC10 XS7T4NC440 XS7C1A1NBL2 + XSZBC10
XS2M30MA250L2 XS630B1MAL10 XS7C40DP210TT XS7C1A1DBM8 + XSZBC10 XS7T4NC440LD XS7C1A1NAL01M12 + XSZBC10
Proximity Sensors
Existing to New Substitution
© 1997-2002 Schneider Electric All Rights Reserved
330 10/02
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
XS7T4NC440LD XS7C1A1NBL01M12 + XSZBC10 XS7 Rectangular
"
XS8C40MP230H7 XS8C1A1MAL01U20 + XSZBC10
XS7T4PC440 XS7C1A1PAL2 + XSZBC10 XS7C40DA210 XS8C1A1MAL01U20 + XSZBC10 XS8C40MP230H7 XS8C1A1MBL01U20 + XSZBC10
XS7T4PC440 XS7C1A1PBL2 + XSZBC10 XS7C40DA210A XS8C1A1MAL01U20 + XSZBC10 XSD Rectangular
$
XS7T4PC440LD XS7C1A1PAL01M12 + XSZBC10 XS7C40DP210 XS8C1A1MAL01U20 + XSZBC10 XSDC407138 XS7D1A1DAM12 + XSZBD10
XS7T4PC440LD XS7C1A1PBL01M12 + XSZBC10 XS7C40DP210 XS8C1A1MBL01U20 + XSZBC10 XSDC407139 XS7D1A1DAM12 + XSZBD10
XS8 Rectangular
$
XS7C40DP210H29 XS8C1A1MAL01U20 + XSZBC10 XSDC407139D4 XS7D1A1DAM12 + XSZBD10
XS8C40DA210 XS7C1A1DAL01M12 + XSZBC10 XS7C40DP210H29 XS8C1A1MBL01U20 + XSZBC10 XSDC407139H7 XS7D1A1DAM12 + XSZBD10
XS8C40DP210 XS8C1A1DAM8 + XSZBC10 XS7C40DP210H7 XS8C1A1MAL01U20 + XSZBC10 XSDC407139LD XS7D1A1DAM12 + XSZBD10
XS8C40DP210 XS8C1A1DBM8 + XSZBC10 XS7C40DP210H7 XS8C1A1MBL01U20 + XSZBC10 XSDC407139LD01 XS7D1A1DAM12 + XSZBD10
XS8C40DP210H29 XS8C1A1DAM8 + XSZBC10 XS7C40DP210TT XS8C1A1MAL01U20 + XSZBC10 XSDC507139 XS7D1A1DAM12 + XSZBD10
XS8C40DP210H29 XS8C1A1DBM8 + XSZBC10 XS7C40DP210TT XS8C1A1MBL01U20 + XSZBC10 XSDC607139 XS7D1A1DAM12 + XSZBD10
XS8C40DP210H7 XS8C1A1DAM8 + XSZBC10 XS7C40DP210TF XS8C1A1MAL01U20 + XSZBC10 XSDC607139H7 XS7D1A1DAM12 + XSZBD10
XS8C40DP210H7 XS8C1A1DBM8 + XSZBC10 XS7C40DP210TF XS8C1A1MBL01U20 + XSZBC10 XSDC607139LD XS7D1A1DAM12 + XSZBD10
XS8C40NC440 XS8C1A1NAM8 + XSZBC10 XS7C40FP260 XS8C1A1MAL01U20 + XSZBC10 XSDC607139LD01 XS7D1A1DAM12 + XSZBD10
XS8C40NC440 XS8C1A1NBM8 + XSZBC10 XS7C40FP260 XS8C1A1MBL01U20 + XSZBC10 XSDC607319 XS7D1A1DAM12 + XSZBD10
XS8C40NC440H29 XS8C1A1NAM8 + XSZBC10 XS7C40FP260A XS8C1A1MAL01U20 + XSZBC10 XSDC607319 XS7D1A1DBM12 + XSZBD10
XS8C40NC440H29 XS8C1A1NBM8 + XSZBC10 XS7C40FP260A XS8C1A1MBL01U20 + XSZBC10 XSDH407339 XS8D1A1PAM12 + XSZBD10
XS8C40NC449 XS8C1A1NAM8 + XSZBC10 XS7C40FP260H29 XS8C1A1MAL01U20 + XSZBC10 XSDH407339 XS8D1A1PBM12 + XSZBD10
XS8C40NC449 XS8C1A1NBM8 + XSZBC10 XS7C40FP260H29 XS8C1A1MBL01U20 + XSZBC10 XSDH407339H7 XS8D1A1PAM12 + XSZBD10
XS8C40NC449H29 XS8C1A1NAM8 + XSZBC10 XS7C40FP260H7 XS8C1A1MAL01U20 + XSZBC10 XSDH407339H7 XS8D1A1PBM12 + XSZBD10
XS8C40NC449H29 XS8C1A1NBM8 + XSZBC10 XS7C40FP260H7 XS8C1A1MBL01U20 + XSZBC10 XSDH607339 XS8D1A1PAM12 + XSZBD10
XS8C40NC449H7 XS8C1A1NAM8 + XSZBC10 XS7C40FP260TF XS8C1A1MAL01U20 + XSZBC10 XSDH607339 XS8D1A1PBM12 + XSZBD10
XS8C40NC449H7 XS8C1A1NBM8 + XSZBC10 XS7C40FP260TF XS8C1A1MBL01U20 + XSZBC10 XSDH607339H7 XS8D1A1PAM12 + XSZBD10
XS8C40PC440 XS8C1A1PAM8 + XSZBC10 XS7C40FP260TT XS8C1A1MAL01U20 + XSZBC10 XSDH607339H7 XS8D1A1PBM12 + XSZBD10
XS8C40PC440 XS8C1A1PBM8 + XSZBC10 XS7C40FP260TT XS8C1A1MBL01U20 + XSZBC10 XSDH607339TF XS8D1A1PAM12 + XSZBD10
XS8C40PC440D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSDH607339TF XS8D1A1PBM12 + XSZBD10
XS8C40PC440D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230 XS8C1A1MBL01U20 + XSZBC10 XSDJ407339 XS8D1A1NAM12 + XSZBD10
XS8C40PC440H29 XS8C1A1PAM8 + XSZBC10 XS7C40MP230A XS8C1A1MAL01U20 + XSZBC10 XSDJ407339 XS8D1A1NBM12 + XSZBD10
XS8C40PC440H29 XS8C1A1PBM8 + XSZBC10 XS7C40MP230A XS8C1A1MBL01U20 + XSZBC10 XSDJ407339H7 XS8D1A1NAM12 + XSZBD10
XS8C40PC440H7 XS8C1A1PAM8 + XSZBC10 XS7C40MP230H29 XS8C1A1MAL01U20 + XSZBC10 XSDJ407339H7 XS8D1A1NBM12 + XSZBD10
XS8C40PC440H7 XS8C1A1PBM8 + XSZBC10 XS7C40MP230H29 XS8C1A1MBL01U20 + XSZBC10 XSDJ607339 XS8D1A1NAM12 + XSZBD10
XS8C40PC449 XS8C1A1PAM8 + XSZBC10 XS7C40MP230H7 XS8C1A1MAL01U20 + XSZBC10 XSDJ607339 XS8D1A1NBM12 + XSZBD10
XS8C40PC449 XS8C1A1PBM8 + XSZBC10 XS7C40MP230H7 XS8C1A1MBL01U20 + XSZBC10 XSDJ607339H7 XS8D1A1NAM12 + XSZBD10
XS8C40PC449D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230TF XS8C1A1MAL01U20 + XSZBC10 XSDJ607339H7 XS8D1A1NBM12 + XSZBD10
XS8C40PC449D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230TF XS8C1A1MBL01U20 + XSZBC10 XSE Rectangular
$
XS8C40PC449H29 XS8C1A1PAM8 + XSZBC10 XS7C40MP230TT XS8C1A1MAL01U20 + XSZBC10 XSEC107130 XS7E1A1DAL01M12 + XSZBE10
XS8C40PC449H29 XS8C1A1PBM8 + XSZBC10 XS7C40MP230TT XS8C1A1MBL01U20 + XSZBC10 XSEC1071300 XS7E1A1DAL2 + XSZBE10
XS8C40PC449H7 XS8C1A1PAM8 + XSZBC10 XS8 Rectangular
"
XSEC1071300L05 XS7E1A1DAL01M12 + XSZBE10
XS8C40PC449H7 XS8C1A1PBM8 + XSZBC10 XS8C40DA210 XS8C1A1MAL01U20 + XSZBC10 XSEC1071301 XS7E1A1DAL01M12 + XSZBE10
XS8T2NC440 XS8E1A1NAL2 + XSZBE10 XS8C40DP210 XS8C1A1MAL01U20 + XSZBC10 XSEC1071302 XS7E1A1DAL01M12 + XSZBE10
XS8T2NC440 XS8E1A1NBL2 + XSZBE10 XS8C40DP210 XS8C1A1MBL01U20 + XSZBC10 XSEC1071304 XS7E1A1DAL01M12 + XSZBE10
XS8T2NC440LD XS8E1A1NAL01M12 + XSZBE10 XS8C40DP210H29 XS8C1A1MAL01U20 + XSZBC10 XSEC107130D4 XS7E1A1DAL01M12 + XSZBE10
XS8T2NC440LD XS8E1A1NBL01M12 + XSZBE10 XS8C40DP210H29 XS8C1A1MBL01U20 + XSZBC10 XSEC107130H7 XS7E1A1DAL01M12 + XSZBE10
XS8T2PC440 XS8E1A1PAL2 + XSZBE10 XS8C40DP210H7 XS8C1A1MAL01U20 + XSZBC10 XSEC107133 XS7E1A1DAL01M12 + XSZBE10
XS8T2PC440 XS8E1A1PBL2 + XSZBE10 XS8C40DP210H7 XS8C1A1MBL01U20 + XSZBC10 XSEC1071330 XS7E1A1DAL2 + XSZBE10
XS8T2PC440LD XS8E1A1PAL01M12 + XSZBE10 XS8C40FP260 XS8C1A1MAL01U20 + XSZBC10 XSEC1071331 XS7E1A1DAL01M12 + XSZBE10
XS8T2PC440LD XS8E1A1PBL01M12 + XSZBE10 XS8C40FP260 XS8C1A1MBL01U20 + XSZBC10 XSEC1071332 XS7E1A1DAL01M12 + XSZBE10
XS8T4NC440 XS8C1A1NAL2 + XSZBC10 XS8C40FP260H29 XS8C1A1MAL01U20 + XSZBC10 XSEC1071334 XS7E1A1DAL01M12 + XSZBE10
XS8T4NC440 XS8C1A1NBL2 + XSZBC10 XS8C40FP260H29 XS8C1A1MBL01U20 + XSZBC10 XSEC107133D4 XS7E1A1DAL01M12 + XSZBE10
XS8T4NC440LD XS8C1A1NAL01M12 + XSZBC10 XS8C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSEC107230 XS7E1A1DBM12 + XSZBE10
XS8T4NC440LD XS8C1A1NBL01M12 + XSZBC10 XS8C40MP230 XS8C1A1MBL01U20 + XSZBC10 XSEC1072301 XS7E1A1DBL01M12 + XSZBE10
XS8T4PC440 XS8C1A1PAL2 + XSZBC10 XS8C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSEC107233 XS7E1A1DBM12 + XSZBE10
XS8T4PC440 XS8C1A1PBL2 + XSZBC10 XS8C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSEC1072331 XS7E1A1DBL08M12 + XSZBE10
XS8T4PC440LD XS8C1A1PAL01M12 + XSZBC10 XS8C40MP230H29 XS8C1A1MAL01U20 + XSZBC10 XSEC1571300 XS7E1A1DAL2 + XSZBE10
XS8T4PC440LD XS8C1A1PBL01M12 + XSZBC10 XS8C40MP230H29 XS8C1A1MBL01U20 + XSZBC10 XSEC1571330 XS7E1A1DAL2 + XSZBE10
Proximity Sensors
Existing to New Substitution
331
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Existing to New Substitution
Old Design New Design Old Design New Design Old Design New Design
XSC Rectangular
"
XSCA150549 XS8C1A1MAL01U20 + XSZBC10
XSCA150549 XS8C1A1MBL01U20 + XSZBC10
XSD Rectangular
"
XSDA400519 XS8D1A1MAU20 + XSZBD10
XSDA400519 XS8D1A1MBU20 + XSZBD10
XSDA400519H7 XS8D1A1MAU20 + XSZBD10
XSDA400519H7 XS8D1A1MBU20 + XSZBD10
XSDA500519 XS8D1A1MAU20 + XSZBD10
XSDA500519 XS8D1A1MBU20 + XSZBD10
XSDA500519H7 XS8D1A1MAU20 + XSZBD10
XSDA500519H7 XS8D1A1MBU20 + XSZBD10
XSDA505539H4 XS8D1A1MAU20 + XSZBD10
XSDA505539H4 XS8D1A1MBU20 + XSZBD10
XSDA600519 XS8D1A1MAU20 + XSZBD10
XSDA600519 XS8D1A1MBU20 + XSZBD10
XSDA600519H7 XS8D1A1MAU20 + XSZBD10
XSDA600519H7 XS8D1A1MBU20 + XSZBD10
XSDM500538 XS8D1A1MAU20 + XSZBD10
XSDM500538 XS8D1A1MBU20 + XSZBD10
XSDM600539 XS8D1A1MAU20 + XSZBD10
XSDM600539 XS8D1A1MBU20 + XSZBD10
XSDM600539H7 XS8D1A1MAU20 + XSZBD10
XSDM600539H7 XS8D1A1MBU20 + XSZBD10
Proximity Sensors
AC Only to AC/DC Cross Reference
© 1997-2002 Schneider Electric All Rights Reserved
332 10/02
Proximity Sensors
AC Only to AC/DC Cro ss Reference
Obsolete Part Number Replaced by Part Number
AC AC/DC
XS1M12FA260 XS1M12MA230
XS1M12FA260K XS1M12MA230K
XS1M12FB260 XS1M12MB230
XS1M12FB260K XS1M12MB230K
XS1M18FA260 XS1M18MA230
XS1M18FA260A XS1M18MA230A
XS1M18FA260K XS1M18MA230K
XS1M18FB260 XS1M18MB230
XS1M18FB260A XS1M18MB230A
XS1M18FB260K XS1M18MB230K
XS1M30FA260 XS1M30MA230
XS1M30FA260A XS1M30MA230A
XS1M30FA260K XS1M30MA230K
XS1M30FB260 XS1M30MB230
XS1M30FB260A XS1M30MB230A
XS1M30FB260K XS1M30MB230K
XS2M12FA260 XS2M12MA230
XS2M12FA260K XS2M12MA230K
XS2M12FB260 XS2M12MB230
XS2M12FB260K XS2M12MB230K
XS2M18FA260 XS2M18MA230
XS2M18FA260A XS2M18MA230A
XS2M18FA260K XS2M18MA230K
XS2M18FB260 XS2M18MB230
XS2M18FB260A XS2M18MB230A
XS2M18FB260K XS2M18MB230K
XS2M30FA260 XS2M30MA230
XS2M30FA260A XS2M30MA230A
XS2M30FA260K XS2M30MA230K
XS2M30FB260 XS2M30MB230
XS2M30FB260A XS2M30MB230A
XS2M30FB260K XS2M30MB230K
XS3P12FA260 XS3P12MA230
XS3P12FA260K XS3P12MA230K
XS3P12FB260 XS3P12MB230
XS3P12FB260K XS3P12MB230K
XS3P18FA260 XS3P18MA230
XS3P18FA260A XS3P18MA230A
XS3P18FA260K XS3P18MA230K
XS3P18FB260 XS3P18MB230
XS3P18FB260A XS3P18MB230A
XS3P18FB260K XS3P18MB230K
XS3P30FA260 XS3P30MA230
XS3P30FA260A XS3P30MA230A
XS3P30FA260K XS3P30MA230K
XS3P30FB260 XS3P30MB230
XS3P30FB260A XS3P30MB230A
XS3P30FB260K XS3P30MB230K
XS4P12FA260 XS4P12MA230
XS4P12FA260K XS4P12MA230K
XS4P12FB260 XS4P12MB230
XS4P12FB260K XS4P12MB230K
XS4P18FA260 XS4P18MA230
XS4P18FA260A XS4P18MA230A
XS4P18FA260K XS4P18MA230K
XS4P18FB260 XS4P18MB230
XS4P18FB260A XS4P18MB230A
XS4P18FB260K XS4P18MB230K
XS4P30FA260 XS4P30MA230
XS4P30FA260A XS4P30MA230A
XS4P30FA260K XS4P30MA230K
XS4P30FB260 XS4P30MB230
XS4P30FB260A XS4P30MB230A
XS4P30FB260K XS4P30MB230K
Proximity Sensors
What is a Proximity Sensor?
333
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
What is a Proximity Sensor?
It is an important component in an
automation control system.
It transmits information relating to
the operating conditions of a
machine to the logic processing
system:
Presence, passage, flow of
parts
End of travel
Rotation and counting.
Essentially, it is a non-contact
part presence detector.
OSCILLATOR
OUTPUT SWITCH
OUTPUT DRIVER
Detection stage Output stage
no physical contact with no wear, possibility of
the target detecting fragile or freshly
painted objects
high operating rate perfect compatibility with
electronic automated
systems
high approach speeds fast response
rugged, fully excellent resistance to
encapsulated industrial environments
solid state, no moving life of the device is
parts independent
of the number of operations
Composition
Detection stage Output stage
type of mounting (cylindrical, type of supply (DC, AC,
rectangular) AC/DC)
detection characteristics electrical characteristics
(sensing distance, hysteresis) (current and voltage)
Application Advantages
Proximity Sensors
Why the Different Types of Sensors?
© 1997-2002 Schneider Electric All Rights Reserved
334 10/02
Proximity Sensors
Why the Different Types of Sensors?
An inductive proximity sensor is essentially comprised of an oscillator whose windings
constitute the sensing face. An electromagnetic field is generated in front of these windings.
When a metal object is placed within this field, the resulting currents induced into the target
form an additional load, and the oscillations cease.
This causes the output driver to operate, producing an ON or OFF output signal.
Inductive
Identifies only metal targets
Predictable sensing
technology—few variables
Reliable industrial technology
Suitable for the detection of metal objects
Sensor
Target
Target
Principle of operation
Proximity Sensors
Why the Different Types of Sensors?
335
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Why the Different Types of Sensors?
An capacitive proximity sensor is basically comprised of an oscillator whose capacitors
constitute the sensing face.
When a conducting or insulating material with a permittivity greater than air is placed within
this field, it modifies the coupling capacitance and causes oscillations.
This actuates the output driver, and, depending on the model, an ON or OFF output signal is
produced.
Capacitive
•Detects any material
Affected by environment:
humidity, dust, etc.
•Best for:
bulk material
liquids
targets behind a separation
wall
Suitable for the detection of non-conductive
targets, liquids and powders
Principle of operation
Target
Target
Sensor
Proximity Sensors
Detection Stage
© 1997-2002 Schneider Electric All Rights Reserved
336 10/02
Proximity Sensors
Detection Stage
Housing types
LED
LED
Non plug-in type Plug-in type
Tubular type
Block type
Advantages
Metal housing
Short case Standard
(Form A)
Standard
(Form A)
Plastic housing
Short case
omni-directional
LED
omni-directional
LED
• Simple installation and set-up: pre-wired or connector models
• Excellent environmental protection:
- encapsulated
- metal housing (plated brass)
- plastic or stainless steel housing (food, pharmaceuticals)
• Two choices:
- very short for restricted access areas
- standard (form A) length for ease of replacement
• No adjustment replacement by using a patented indexing mounting
bracket
• Direct interchangeability, no need for readjustment
• Flexibility of connections: screw terminals or connector
• Long sensing distance
Indexed
mounting bracket
Stop, for indexing
the proximity sensor
Bracket + sensor
adjustments
Advantages
Proximity Sensors
Sensing Parameters
337
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Sensing Parameters
The targets are generally of steel, and of a size equivalent to the sensing face of the sensor.
To ensure detection, the target should pass at a distance less than or equal to the usable
sensing distance given in the data sheet of the sensor selected.
Operating
zone
Suitabiliy for flush
mounting in metal
Target
Circular LED indicator
Operating state
Operating
zone
No lateral effect Sensing distance + 50 to + 100%
Reduced sensing distance Space required around the device
to eliminate the effects of the
surrounding metal
Suitable (shielded) Not suitable
(unshielded)
Advantages
Advantages
But
But
Proximity Sensors
Output Stage Parameters
© 1997-2002 Schneider Electric All Rights Reserved
338 10/02
Proximity Sensors
Outp ut Stage Parame ters
Check that the power supply range limits of the proximity sensor are compatible with the
nominal voltage of the AC supply used.
Where a DC supply is available, check that the voltage limits of the sensor, including ripple, are
compatible with the supply used.
If an AC supply is available, a suitable DC power supply must be selected. A simple one has a
transformer, a rectifier, and a smoothing capacitor.
Where voltage is derived from a single phase AC supply, it must be rectified and filtered to
ensure that:
The peak voltage of the DC supply is lower than the maximum operating voltage of
the sensor, peak voltage = rated voltage Ve x 2.
The minimum voltage of the DC supply is greater than the minimum voltage rating of
the sensor, given that V = (I x t) ÷ C.
V = maximum ripple: 10% (V)
i = anticipated load current (mA)
t = period of 1 cycle (8.8 m sec. full wave rectified 60 Hz frequency voltage)
C = capacitance (µF)
As a general rule, use a transformer with a lower secondary voltage (Ue) than the required
DC voltage (U).
Example: 18 Vac to obtain 24 Vdc
35 Vac to obtain 48 Vdc
Mount a filtering capacitor of minimum 400 µF per sensor or 2000 µF for each ampere of load
current required.
NOTE: Tubular 3 wire DC universal models (10-58 V), 3 wire DC XSF models, and all AC/DC
models can be supplied from full-wave rectified non-filtered (no capacitor C in the diagram
above) power supplies.
Power supply
AC or AC/DC sensors
for AC circuits
Sensors for DC circuits
Ve
Vs
Vs without C
(non-filtered)
C
AC
50 - 60 Hz
-
t
voltage
V peak
V av.
V rms
V
V
V
+
Proximity Sensors
Output Stage Parameters
339
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Out put Stage Parame ters
2 wire sensors are wired in series with the load to be switched.
They are subject to:
a residual current (leakage current) - in the open state
a voltage drop - in the closed state
For the AC and AC/DC versions, certain models are protected against short-circuits. Refer to
the product characteristics.
Output signal
2 Wire type
XS
RLoad
~/
~/
AC/DC 2 wire BN
BU
XS
RLoad
~
~
AC 2 wire BN
BU
XS
RLoad
-/+
+/-
DC, 2 wire, not polarity conscious BN
BU
They can be wired in the same way as mechanical limit switches.
For the DC and AC/DC versions, they can be connected to either
positive (PNP) or negative (NPN) logic inputs.
Polarity insensitive versions, no risk of incorrect connection.
• AC/DC versions, reduces stock requirements
Advantages
Check the possible effects of residual current and voltage drop on the
input device controlled (pick-up and drop-out thresholds).
But
Proximity Sensors
Output Stage Parameters
© 1997-2002 Schneider Electric All Rights Reserved
340 10/02
Proximity Sensors
Outp ut Stage Parame ters
The sensors in this category have:
2 wires for the power supply
1 wire for the output signal
NOTE: Some models include an additional wire for a complementary output 4 wire type, N.O.
+ N.C. The technology is still 3 wires.
They are protected against reverse supply polarity and against overloads and short-circuit of
the load. For the DC version, there are two types of sensor:
Basic sensor
PNP model, switching the positive side to the load (sourcing)
NPN model, switching the negative side to the load (sinking)
Universal DC sensors
A single universal sensor, depending on the wiring connections can perform any of the
following 4 functions: PNP/N.O., PNP/N.C., NPN/N.O., NPN/N.C.
Output signal
3 Wire type
XS
3 wire type, programmable
PNP/NPN/N.O./N.C.
C
BN
BK
+-BN
BK
C
BU BU
NPN
N.C.
PNP
N.O.
Polarity (case 1)
-
+
BN
BK
C
BU
PNP
N.C.
NPN
N.O.
Polarity (case 2)
-
+
L : Load
XS
LoadS
+
-
3 wire type
PNP
BN
BU
XS
LoadS
+
-
3 wire type
NPN
BN
BU
C C
Advantages
But
N.O. + N.C. versions
Universal versions, reduces stock requirements
Requires the use of a specialized sensor (PNP or NPN, function of the
load connection, to negative or positive, respectively) or a selectable
universal type.
Best switching characteristics: no residual current, low voltage drop, fast
Proximity Sensors
Output Stage Parameters
341
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Out put Stage Parame ters
These proximity sensors convert the approach of a metal target towards the sensing face into
a current output signal which is proportional to the distance between the target and the
sensing face.
Two models:
dual voltage: 24/48 Vdc
Output: 0 - 10 mA with 3 wire connection
4 - 14 mA with 2 wire connection
single voltage: 24 Vdc
Output: 0 - 16 mA with 3 wire connection
4 - 20 mA with 2 wire connection
Output signal
Analog type
Load
-
S
+
I
XS
Load
-
S
+
I
XS
3 wire type 2 wire type
• Output signal proportional to the distance.
• Two or three wire connection using the same device.
Advantages
Proximity Sensors
Output Stage Parameters
© 1997-2002 Schneider Electric All Rights Reserved
342 10/02
Proximity Sensors
Outp ut Stage Parame ters
Namur type proximity sensors (DIN 19234) are electronic sensors in which the current
consumption varies when a metal object approaches.
Their operating principle, together with their compact size, enables them to be used in a large
number of applications:
Intrinsically safe (hazardous environments, i.e. explosive). Sensors are used with NY2
intrinsically safe relay/amplifier or equivalent, approved intrinsically safe solid state input.
Non-intrinsically safe (normal, safe zone). NAMUR sensors associated with a power supply
and amplifier unit or equivalent solid state input.
Output signal
Namur type
+
-
7 to 12 Vdc
R = 1K
Load
• Basic product, without amplifier.
• Compact size.
• Can work in hazardous environments.
Advantages
Proximity Sensors
Output Stage Parameters
343
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Out put Stage Parame ters
Method of
connection
Cable Connector Screw Terminals
Ease of
installation and
replacement.
Features
Features
Features
Note
Pre-wired sealed
cable, excellent
resistance to
splashing liquid
(IP67) or cutting
oils (IP68).
Flexibility: user
selects type and
length of cable.
In practice, the preceding information enables the selection and installation
of a proximity sensor for applications having normal operating conditions.
The following pages contain details for applications which need more
specific information.
Proximity Sensors
Environmental Parameters
© 1997-2002 Schneider Electric All Rights Reserved
344 10/02
Proximity Sensors
Environmental Parameters
The XS sensors are tested according to IEC 60947.5.2 standard (similar to the proposed new
NEMA ICS 5-4-1999x standard).
Electromagnetic
interference
IEC 1000-4-3
10 V / meter
LEVEL 3
ELECTRO-MAGNETIC
WAVES
WALKIE
TALKIE
RADIATING ELECTRO-MAGNETIC FIELD
SHOCK VOLTAGES
TRANSFORMER
MAINS
FACTORY
OVERVOLTAGE
IMPULSE VOLTAGE
LIGHTNING
ELECTRO-STATIC
DISCHARGE
IEC 1000-4-2
10 kV4 kV 15 kV
LEVEL
3
LEVEL
2
LEVEL
4
INSULATING
FLOOR
(carpeting)
ELECTRO-STATIC DISCHARGES
FAST TRANSIENTS
IEC 1000-4-4
1 kV 2 kV
LEVEL
3
0.5 kV
LEVEL
2
LEVEL
4
MOTOR
STOP
START
CONTROL
MOTOR START/STOP
INTERFERENCE
CAPACITIVE COUPLING
IEC 947.5.2
2,5 kV 5 kV
LEVEL
3
1 kV
LEVEL
2
LEVEL
4
DC versions
level 2 immunity (3 wire type)
level 3 immunity (2 wire type)
AC/DC versions
level 4 immunity
DC and AC/DC versions
level 3 immunity
(RFI Radio Frequency
Immunity)
DC versions
level 3 immunity
AC/DC versions
level 4 immunity
Extended range DC
level 3 immunity
DC and AC/DC versions
level 3 immunity (over 8 mm
diameter)
level 2 immunity (tubular 8 mm
and smaller)
Proximity Sensors
Environmental Parameters
345
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Environmental Parameters
Temperature: where sensors are used outside the ranges shown, reliable operation cannot
be assured and permanent damage could result.
Standard length tubular sensors have a very large temperature range: -25° C to 80° C.
NOTE: For extended temperature range, consult factory.
Chemicals: due to the very wide range of chemicals which are found in modern industry, it is
very difficult to give general guidelines on sensor applications.
To ensure lasting efficient operation, it is essential that the chemicals coming in contact with
the sensors will not affect their housings and, in doing so, prevent their reliable operation.
The XS1/XS2 M series is particularly well adapted to the severe environment, such as
machine tool applications.
NOTE: The cables used conform to standard NFC 32 206 and to recommendations CNOMO
E03-40-150 N. They are UL Listed and CSA Certified.
The series XS4P plastic cylindrical proximity sensors as well as the stainless steel XS1/
XS2 sensors exhibit excellent overall resistance to:
Chemical products, such as salts, halophytic and aromatic oils, petrols, acids, and diluted
bases. For acids, ketones, and phenols, preliminary test should be made according to the
nature and concentration of the liquid.
Agriculture and food industry products, such as animal and vegetable based food
products (vegetable oils, animal fat, fruit juice, dairy proteins, etc...).
NOTE: For specific details, please consult factory. Have the following information available
when making the inquiry:
type of substance
concentration
maximum temperature
specific sensor(s) part numbers considered for the application
Temperature
Chemicals
Proximity Sensors
Environmental Parameters
© 1997-2002 Schneider Electric All Rights Reserved
346 10/02
Proximity Sensors
Environmental Parameters
Shocks
The sensors are tested according to IEC 60068.2.27, 50g, duration 11 m sec.
Vibrations
The sensors are tested according to IEC 60068.2.6, amplitude ± 2 mm, F = 10-55 Hz, 25g
to 55 Hz.
Degrees of protection
IP67 - protection against the effects of immersion, tested according to IEC 60529. Sensor
immersed for 30 minutes in 1 meter of water.
UL Listed: typical NEMA 4X, 6P, 12. No deterioration in either operating or insulation
characteristics.
IP68 - protection against effects of prolonged immersion: the test conditions are subject to
agreement between the manufacturer and user.
Telemecanique selected machine tool applications or other machines frequently drenched
in cutting fluids. IP68 means, in this case, cutting oil proof, a degree of protection requiring
a superior encapsulation technology. Extensive testing is performed—1500 hours
immersion in fluid at 70° C.
Shocks – Vibrations
Proximity Sensors
Definition of Terms
347
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Definition of Ter ms
Nominal (or rated) sensing distance Sn:
The rated operating distance for which the sensor is designed. It does not take into account
manufacturing tolerances, or any change in supply voltage, temperature, etc... during
operation. Used for selection and base for exact calculations.
Real sensing distance Sr:
The real sensing distance is measured at rated voltage (Un) and at the rated ambient
temperature (Tn). It must be between 90% and 110% of the real sensing distance: 0.9Sn Sr
1.1Sn.
Usable sensing distance Su:
The usable sensing distance is measured at the limits of the permissible variations of the
ambient temperature (Ta) and the supply voltage (Ub). It must be between 90% and 110% of
the real sensing distance: 0.9Sr Su 1.1Sr.
Operating zone Sa (usable sensing range):
The operating zone is between 0 and 81% of the nominal sensing distance Sn:
0 Sa 0.81Sn
This is the operating zone of the sensor and corresponds to the area within which detection
of the standard metal target is certain whatever the variations in voltage or temperature.
This is the maximum sensing distance the designer should consider for all applications.
Correction factors should be considered only when conditions preclude the use of the
standard target in the operating temperature and voltage range.
Definition of
sensing distances
Output
ON
Standard metal target
S Certain detection
Output
OFF
Sensing face
S max + H
u
S max + H
r
S + H
n
S min + H
r
S min + H
u
Su max
a
Sr max
Sn
Sr min
Su min
Proximity sensor
Proximity Sensors
Definition of Terms
© 1997-2002 Schneider Electric All Rights Reserved
348 10/02
Proximity Sensors
Definition of Ter ms
Standard metal target:
1 mm thick, square mild cold rolled steel, type FE 360. The side of the square is either equal
to the diameter of the sensor or of the circle engraved on the active face of the sensing face or
is 3 times the nominal sensing distance (Sn). The higher of these values is used.
Differential travel: (hysteresis) H:
The distance between the pick-up point as the standard metal target frontally approaches the
sensor, and the drop-out point as it moves away. Expressed as a percentage of the real sensing
distance Sr.
Repeat accuracy (repeatability) R:
The repeatability of the sensing distance, between successive operations. Readings are taken
over a period of time while the sensor is subjected to environmental extremes, e.g. 8 hour cycle
between 10 and 30° C, with supply voltage variation ± 5% of nominal. Expressed as a
percentage of the real sensing distance Sr. Important parameter for positioning applications.
Class 2 material - Double isolation
The symbol represents electrical insulation conforming to IEC 60536
class 2. It means that all live parts are isolated inside the housing and
touching any exterior exposed metal is harmless. No groundings
required.
International symbol for proximity switches.
Standard metal
target
Differential
travel
Repeat accuracy
(Repeatibility
Class 2 material
Double Isolation
Symbol
Drop-out point
Pick-up point
H
Sensing distance
Frontal approach Standard target
Proximity sensor
Proximity Sensors
Definition of Terms
349
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Definition of Ter ms
The leakage or residual current corresponds to the current flowing through the sensor in the
OFF or “open” state. Important for 2 wire proximity sensors.
The voltage drop corresponds to the voltage at the proximity sensors terminals in the ON or
“closed” state.Especially important for 2 wire proximity sensors.
The period of time between energizing the sensor and its fully operational condition. Known
also as “warm-up” or “first-up” delay.
The maximum number of targets a proximity sensor can detect in a second, under standard
test conditions (standard EN50018, IEC 60947.5.2). Do not use for selection or design
purposes unless the geometry of the application is identical with the one in the picture.
Leakage or
Residual current
(lr)
Voltage drop
(Ud)
RESPONSE TIME
power-up delay
Maximum operating
frequency
XS
mA
Supply
Load
XS
Supply
Load
V
Power supply
Sensor output
t
Proximity sensor
1/2 Sn
m2m
Standard metal
target
Non metallic
material Output signal
T on T off
1
f =
(T on + T off)
Proximity Sensors
Definition of Terms
© 1997-2002 Schneider Electric All Rights Reserved
350 10/02
Proximity Sensors
Definition of Ter ms
ON delay Ra:
The period between the detection of the target and the subsequent change in its output state.
This design parameter determines the relationship between the speed of travel and the size of
the target.
OFF delay Rr:
The period between the exit of the target from the sensor’s operating zone and the subsequent
change in its output state. This design parameter limits the interval between successive
targets.
N.O. - Normally open
Output circuit turns ON output current when a target
is present.
N.C. - Normally closed
Output circuit turns OFF output current when a
target is present.
N.O. + N.C.
Complementary outputs proximity sensor with two
outputs, one of which opens, the other closes when
a target is present.
Response time
Output signal
RrRa
Presence of the target
Absent
Present
OFF
ON
Proximity sensor output signal
XS
XS
XS
"NO" output
"NC" output
NO + NC
output
Proximity Sensors
Sensing Distance Correction Factors
351
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Sensing D istance Corre ction Factors
In practice, most targets are generally made of steel and are of a size, equal to or
greater than the sensing face of the sensor. Where this is the case, use the sensing
distance values given in the characteristics for the particular sensor. To calculate the precise
sensing distance for specific applications, the following parameters, which affect the sensing
distance, must be taken into account.
Target material correction coefficient Km
Target
Material
Stainless Steel Mild Steel Brass Aluminum Copper
Magn. Type 316 Type 304 A37 UZ33 AU4G CU
Km 1.00 0.70 0.30 1.00 0.37 0.35 0.30
Theoretical
calculation
-25 0 20 50 70 temperature C
θ
K
Temperature
θK
0,9
Real
sensing
distance
1
0,5
Km
magn. type 316 type 304 UZ33 AU4G CuA37
Stainless steel Alum. CopperBrassSteel
Material
Apply a correction factor K
θ
to be determined using the curve above.
1,1
Km
0.40.30.20.1
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.5 1 1.5
Typical curve for a copper target with an 18mm dia. cylindrical model
thickness
in mm
Thickness
Application tip: Aluminum foil on a nonmetallic surface makes an
excellent target.
Apply a correction factor Km
to be determined using the graph above.
Special case of a very thin target object made of non-ferrous material.
Proximity Sensors
Sensing Distance Correction Factors
© 1997-2002 Schneider Electric All Rights Reserved
352 10/02
Proximity Sensors
Sensing D istance Corre ction Factors
For all situations, use the general correction factor Kt = 0.9 for power supply variations within
the entire voltage range.
Sa = Sn x KΘ x Km x Kd x Kt
Where Sa = usable sensing distance
Sn = nominal sensing distance
Proximity sensor XS7C40MP230 with nominal sensing distance Sn = 15 mm.
Ambient temperature variation 0° C to + 20° C.
Target characteristics:
material: Steel
dimensions: 45 mm x 45 mm x 1 mm
The operating zone, Sa can be found using the formula:
Sa = Sn x KΘ x Km x Kd x Kt
Sa = 15 x 0.98 x 1 x 0.95 x 0.9
Sa = 12.5 mm
For standard targets, the rule of thumb is:
Sa = 0.8 Sn
Calculation
example
Usable sensing
distance
Rule of thumb
Always test!
Kd
Dimension
length of the
object to be
detected
4 Sn3Sn2SnSn
1
0.9
0.8
0.7
0.6
0.5
0.4
0,3
0.2
0.1
Apply a correction factor Kd
to be determined using the curve above.
The above curves are typical curves only. They are given as a guide to
the approximate usable sensing distance of a proximity sensor for a
given application
Note
Proximity Sensors
Mechanical Installation
353
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Mechanic al Installation
Mounting
Patented design
No adjustment replacement Indexed mounting bracket XSZB
STEP 1
STEP 2
screw V
STEP 3
screws F
If for any reason adjustment or replacement is necessary:
- Unscrew screw V
- Butt the new sensor against the stop. Once screw V has
been tightened, the new sensor will be indexed in the same
position as the old one. No adjustment is necessary.
Note: these functions are similar to those of a block type sensor
Insert the sensor in the bracket until it
butts against the stop.
Secure the sensor using V screw.
Adjust the sensor/bracket combination to
assure detection.
Secure the combination using F screws.
Proximity Sensors
Mechanical Installation
© 1997-2002 Schneider Electric All Rights Reserved
354 10/02
Proximity Sensors
Mechanic al Installation
Clearing distances
Tubular proximity sensor
Target
3 Sn
dia.
3 dia.
2 Sn
Extended range model
3 Sn
0,2 dia
Standard model
3 Sn
e (mm)
metal
metal
metal metal
metal
metal
metal
Target
Versions not suitable for flush mounting in metal (non-shielded)
Versions suitable for flush mounting in metal (shielded)
Mounting with XSZ B mounting bracket
Versions suitable for
flush mounting in metal
e (min): 0
Versions not suitable
for flush mounting in
metal
M8 e (min): 5 mm
M12 e (min): 8 mm
M18 e (min): 16 mm
M30 e (min): 30 mm
Proximity Sensors
Mechanical Installation
355
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Mechanic al Installation
NOTE: For shorter distances, alternate frequency models are required. Call factory for
availability.
Clearing distances
Side by side
Face to face
Block type proximity sensors
not suitable for mounting in metal
Sensing
face
1,5 a
1,5 a
a
Sensing
face
1,5 a
3 Sn
40
a
Sensing
face
2 a
2 a
a
2 a
Sensing
face
2 a
3 Sn
a
40
Sensing
face
a
1,5 a
3 Sn
Sensing
face
a
2 a
2 a
3 Sn
Mounting into a T section Mounting into a U section
Non-shielded
metal
metal
metal
metal
metal
metal
metal
metal
metal
metal
metal
metal
Side by side
e
Face to face
e
Proximity Sensors
Mechanical Installation
© 1997-2002 Schneider Electric All Rights Reserved
356 10/02
Proximity Sensors
Mechanic al Installation
Any metal within the immediate vicinity of a proximity sensor distorts the magnetic field around
the sensing face. The clearance distances shown above are given for a simplified installation
arrangement and would result in the increase of the sensing distance of less than 5%.
Suitable for flush mounting in metal
Mounting with metal on one or more sides simultaneously
e
e (min): 0
not to be
recess mounted
not to be mounted
adjacent to an
angle section
Shielded
metal
metal
metal
Proximity Sensors
Mounting Tips
357
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Mounting T ips
Precautions
Protection of the cable
10 cm
Sensor on
moving support
mobile carrier
fixed support
Cable clamps
incorrect
correct
F
incorrect
correct
CNOMO adaptor
protective sleeve
Avoid repetitive flexing movement between the cable and the sensor.
The sensor must never be used as a mechanical stop as this may cause
irreparable damage.
Protection of the sensing face
Do not exert a pulling force of
over 4.4 lb on the sensor cable.
Consider using a protective sleeve
or rigid conduit, where necessary.
Proximity Sensors
Mounting Tips
© 1997-2002 Schneider Electric All Rights Reserved
358 10/02
Proximity Sensors
Mounting T ips
Use of tools for adjustment
of the proximity sensor
appropriate tool
Incorrect Correct
Mounting
Tubular sensor Block type sensor
Ensure a rigid mounting
the mounting must be sufficiently
rigid and thick to resist shock
and vibrations
Ensure a rigid mounting
the mounting area must be large
enough to support the sensor
correctly
Proximity Sensors
Mounting Tips
359
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Mounting T ips
Remember: For proper installation, the sensor must be mounted solidly to its support.
Depending on the application, the adjustment of the operating distance is carried out:
either by moving the mounting bracket
or by adjusting the target
Precautions
Positioning
Sensing face
Sensing face
Top
Bottom
Top
Bottom
Sensing face
Mechanical protection
Incorrect Correct
danger of debris collecting on
the sensor sensing face
danger of liquid entry should
the cable gland be mounted
improperly
A proximity sensor should never
be used as a footrest
Where the possibility of this type
of abuse exists, a protective
cover should be fitted over the
sensor
Proximity Sensors
PLC Compatibility
© 1997-2002 Schneider Electric All Rights Reserved
360 10/02
Proximity Sensors
PLC Comp atib ility
In order for a solid state, 2 wire, AC sensor to be directly compatible with a PLC, two conditions
have to be met:
1. Leakage current: (I off) less than 1.7 mA (Off state)
2. Load current: greater than the sensor minimum load current (ON state). Typical PLC
input currents (load current, I load) are 12-16 mA. Typical values for PLC input resistance (Rin)
are: 7.5-10 k.
For sensors which do not meet both of the requirements, a Bleeder Resistor (Rb) has to be
wired in parallel with the load.
For each of the two situations, the Bleeder Resistor parameters have to be calculated as shown
below. The smaller value should be selected for the application.
1. Rb = Rin x Vo Max Pb = Vs2
I off (Rin) – Vo max Rb
Where: Vo max = PLC input maximum OFF voltage (20-40 Vac)
Rin = PLC input resistance
Vs = Line voltage
Pb = Minimum Bleeder Resistor power rating
Example:
I off = 3.5 mA
Vo max = 20 V
Rin = 6.5 k
Typical examples for Telemecanique TSX DET input modules:
TSX DET 1604 TSX DET 0804
For I off = 3.5 mA 47 k/0.5 W
For I off = 7 mA 4.7 k/3 W 12 k/1.5 W
2. Rb = Rin x Vo Max Pb = Vs2
I off (Rin) – Vo max Rb
Example:
I min = 30 mA
Vs = 120 V
Rin = 7 k
Typical examples using TSX programmable controllers:
TSX DET 1604 TSX DET 0804
For I min = 20 mA 64 k/0.5 W 24 k/1 W
For I min = 30 mA 8.7 k/2 W 8.7 k/2 W
NOTE: All DC 3 wire sensors are PLC compatible.
V supply
Sensor
Rb Rin
PLC
Proximity Sensors
Electrical Installation
361
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Electrical Ins tallation
The following points should be considered:
1. When in the open state, each sensor will share the supply voltage:
voltage across the sensor = V supply
n° proximity sensors
V sensor and V supply must fall within the sensor’s voltage range.
2. If a sensor is OFF, it will be supplied with nearly all the supply voltage.
3. When all sensors are ON, a small voltage drop is present across each sensor; the result-
ant loss of voltage at the load will be the sum of the individual voltage drops, and the load
voltage should be selected accordingly.
4. Series connection is only possible for sensors with a wide voltage range.
Example: Four sensors rated at 24-240 Vac can be wired in series at 120 V because even
at 90%, V supply = 108 V. When all sensors are OFF, each will see 108/4 = 27 V,
which is higher than the minimum voltage rating of the switch (24 V).
Wiring
in series
Wiring two or more sensors in series
2 wire type
V supply
Sensor
" 1"
Sensor
" n "
load
V supply
Proximity Sensors
Electrical Installation
© 1997-2002 Schneider Electric All Rights Reserved
362 10/02
Proximity Sensors
Electrical Ins tallation
The following points should be considered:
1. Sensor 1, when conducting its load current, will also carry the leakage currents of all other
sensors.
2. Each sensor, when conducting, will produce a voltage drop of 2.6 V, maximum. The load
voltage should be selected accordingly.
3. Sensor 2 is powered only when Sensor 1 turns ON. Only after its power-up delay will
Sensor 2 be able to function properly. This delay should be taken into consideration when
speed is a factor.
4. Use of “flywheel” diodes is recommended where an inductive load is being switched.
Wiring two or more sensors in series
3 wire type
Sensor "1"
V supply
+
V supply
-
Sensor "2"
load
Sensor "n"
Proximity Sensors
Electrical Installation
363
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Electrical Ins tallation
The following points should be considered:
1. When the mechanical contact is open, the sensor is not supplied.
2. When the contact closes, the proximity sensor will not operate until a certain time “T” has
elapsed, corresponding to the power-up delay. Please refer to details of individuals sen-
sor characteristics
.
The use of proximity sensors wired in parallel either between themselves or together with
mechanical contacts is not recommended.
When one of the sensors is in the ON state, the sensor in parallel is “shorted out” and thus no
longer supplied.
As the first unit passes into the OFF state, the second sensor will become energized and will be
subject to its power-up delay. This configuration is used where the sensors are working alternately.
When the sensors are OFF, the sum of the leakage currents must be less than the holding
current of the load.
Wiring
in series
Wiring proximity sensors in series with
mechanical contact devices
V supply
+
V supply
-
Mechanical
contact
load
Sensor
fuse
Wiring several sensors in parallel
2 wire type
3 wire type
No restriction
Sensor "1" V supply
-
V supply
+
Sensor "n"
load
Proximity Sensors
Electrical Installation
© 1997-2002 Schneider Electric All Rights Reserved
364 10/02
Proximity Sensors
Electrical Ins tallation
Length of the cable
No restrictions up to 660 feet (200 meters) or up to a line capacitance of 0.1 µF. It i s
important to take into account voltage drop on the line over 660 feet (200 meters).
The XS models are immune to electrical interference encountered in normal industrial
conditions.
Where extreme electrical noise conditions could occur (large motors, spot welders, etc.) it may
be advisable to protect against transients in the following ways:
Suppress interference at source, limit the length of the cables, separate power and
control wiring from each other, ensure that the logic systems contain input transient
suppression means and use twisted pair and shielded cables.
* Use of individual cables is recommended if long lengths are involved.
Precautions
Separation of power and control wiring
control cables *
power cables
10 cm
4 in
correct
incorrect
conduit
high voltage
or power cables
Incorrect
Correct
Proximity Sensors
Wiring Tips
365
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Wiring Tips
Precautions
Electrical connections to be avoided
XS
+
-
R
XS
+
-
solution
XS
AC
XS
AC
Load
If the load consists of an
incandescent lamp, the cold state
resistance can be ten times
lower than the hot state
resistance. This can cause very
high current levels on switching
Install a pre-heat resistance in
parallel with the proximity sensor.
V= supply voltage
P= power of lamp
An XS proximity sensor cannot be
connected directly to an AC
supply source. This would result
in immediate destruction of the
sensor and considerable danger
to the operator
A suitable load (see product data)
must be connected in series with
the proximity sensor.
R= V x 10
2
P
(except short circuit protected
switches)
Proximity Sensors
Troubleshooting Guide
© 1997-2002 Schneider Electric All Rights Reserved
366 10/02
Proximity Sensors
Troubleshooting Guide
Problems
The sensor’s output will not
change state when a metal target
is moved within its operating zone
.
False or erratic operation with or
without the presence of the targe
t
object.
Remedial actionPossible cause
• Check that the sensor is the correct
one for the supply being used.
• Check the load current.
Characteristics:
- If load current is greater than the max.
rated current, a relay should be inter-
posed between the sensor and the load.
- If load current is lower than the nominal
rated current, check for wiring faults
which could have caused a short circuit.
In any case, a fast-blow fuse should be
wired in series with the sensor (AC).
- For a tubular sensor, if the sensor is
brand new, check the mounting torque.
• Check the wiring.
• Check voltage range.
• Check that the supply voltage falls
within the operating limits of the sensor
in question. Remember that with a
rectified supply: Vpeak = Vrms x 2
• Install transient suppressors across
potential sources (coils, arcing
contactors)
Output failure, or the short circuit
protection has operated.
Wiring error
Supply problems
Transients
• Refer to the instruction sheet supplied
with the sensor.
• Ensure that any DC supplies when
derived from rectified AC, are correctly
filtered (C 400 µf)
• Ensure that AC power cables are run
separately from low level DC cables.
• Where very long distances are involved,
use suitable cable:
- shielded and/or twisted pair
- suitable wire gage
• Position the sensor as far away as
possible from any source of interference.
• Check suitability of the sensor for the
target; choose a sensor with a faster
response time or use a longer target.
• Eliminate sources of radiated heat, or
protect the housing with a heat shield.
Influence of surrounding metal
Effect of interference on the supply lines
Response time of the sensor too long for
the particular target.
Effects of high temperature
Proximity Sensors
Troubleshooting Guide
367
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Proximity Sensors
Troubleshooting Guide
Series XS1/XS2 N, XS1/XS2 M, XS4 P also conform to the requirements of IEC 60947.5.2
standard. (ISO 9000 Self-Certification, NEMA project ICS 5-4-199X)
Cenelec
standards
Approvals
File LR46094 + LR44087
class 321103
File E39291
guide NKCR2
File E39281
guide NKCR
Intrinsically safe
applications
Special North American
version (1/2" NPT cable
entry, UL label, etc.)
Standard version
approved
pending
FM
EN 50008
(NFC 63-076)
DC
3 or 4 terminals
EN 50040
(NFC 63-071)
DC
2 terminals
EN 50036
(NFC 63-081)
AC
terminals
Cylindrical Block type
Form A Form C Form D
EN 50025
(NFC 63-077)
DC
3 or 4 terminals
EN 50037
(NFC 63-082)
AC
2 terminals
EN 50026
(NFC 63-078)
DC
3 or 4 terminals
EN 50038
(NFC 63-083)
AC
2 terminals
EN 50010 (NFC 63-075) Determination of sensing
distance and operating frequencies
EN 50032 (NFC 63-079) Definitions, classification, description
EN 50040 (NFC 63-074) Connection identification
XS1 / XS2 L/N
XS1 / XS2 M
XS4P
XS5
USSR
XSB
XS7 / 8
XSD
XSE
XSG
XS6
XS7
XS8
XS9
Proximity Sensors
© 1997-2002 Schneider Electric All Rights Reserved
368 10/02
Proximity Sensors