Proximity Sensors x File 9006 CONTENTS Schneider Electric Brands Description Page Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Auto-adaptable and Standard Flat Inductive Proximity Sensor . . . . . . . . . . . . . . . 206 Auto-adaptable and Standard Cylindrical Inductive Proximity Sensor . . . . . . . . . . 210 Application Specific Flat, Rectangular and Cylindrical . . . . . . . . . . . . . . . . . . . . . . 214 Capacitive Proximity Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294 Magnet Actuated Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 Mechanical Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 Operation and Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 Proximity Sensors Inductive Sensors Interpretation of Catalog Numbers Inductive Sensors / Interpretation of Catalog Numbers I Proximity Sensors C 1 J F E C D L 0 L 0 1 1 1 1 1 4 5 6 8 Cylindrical 12mm 1 2 Cylindrical 18mm Cylindrical 30mm FAMILY TYPE OR MATERIAL Applications Plastic Metal Stainless Steel APPLICATION Operating Mode Food & Beverage Namur Ferrous only Light industry Ferrous/Non-ferrous Non-ferrous only Speed Control Serdac Weld Field Immune OUTPUTS DC 3 wire PNP DC 3 wire NPN DC 3 wire PNP/NPN DC 2 wire (3/4) DC 2 wire automobile (1/4) DC analog output AC 2 wire AC/DC 2 wire AC/DC 2 wire SCP protect AC/DC relay output BUS FUNCTION Analog 0. . .10mA Analog 4.20mA N.O. N.C. N.O. + N.C. Programmable/wiring Programmable CABLING OR CONNECTION M8X1 Nano (S) M12x1 Micro (D) 7/8 16UN Mini (A) 1/2 20 UNF Micro (K) Cable 0.1m Cable 2m Cable 5m Cable 10m M12 micro on0.1m pigtail PG 16 cable gland 1 3 8 0 Example X S 8 A 1 P A L 2 M M U U L L L L L T 8 1 7 2 0 2 5 1 0 1 Inductive Sensor TYPE Cylindrical Optimum Cylindrical Universal Optimum Rectangular Universal Rectangular Application Specific FORMAT OR MODE Rectangular 8x8x20 Rectangular 8x15x32 Rectangular 13x26x26 Rectangular 15x40x40 Rectangular 26x80x80 Cylindrical smooth 4mm Cylindrical 5mm Cylindrical smooth 6mm Cylindrical 8mm 5 6 7 8 9 Proximity Sensors 1...9 A B S 1...9 A E F L M N R S W P N K D C A F M S R B 1 2 A B C P S 2 8 0 1 0 1 6 M 1 2 198 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Inductive Sensors Interpretation of Catalog Numbers PROXIMITY Tubular Inductive Sensors / Interpretation of Catalog Numbers NOTE: This table is intended to understand catalog number designations. It is NOT to be used to create numbers which may not exist. Consult your local field office Rectangular X Example S 7 C 4 0 * * P C N P M D N P P P A P C C 4 4 0 * * * R30 H* SENSOR TYPE Self Contained Component X Z SENSING TECHNOLOGY Inductive Proximity Capacitive Proximity BODY STYLE Miniature Shielded Non-Shielded Block Style FAMILY TYPE Limit Switch Style - Plastic Body Compact Block Sub Compact Block Miniature Cubic MANUFACTURING CODES S T 5 7 8 D OUTPUT TYPE NPN PNP AC/DC Universal 2 wire N.O./N.C. NPN N.O.+N.C. PNP N.O.+N.C. MANUFACTURING CODES SUFFIX 2 Meter Cable or Conduit Opening Blank Micro Connector -- DC D Alternate Frequency F Micro Connector -- AC/DC K 5 Meter Cable L2 10 Meter Cable L10 Mini Connector, Normally Open R30 Mini Connector, Normally Closed R31 Nano Connector -- DC S Bulk Pack TQ * H suffix, which MAY appear on device or carton label, is for manufacturing purposes only. It designates compliance with specific national standards. EX: H7 = UL and CSA approval, 0.5" conduit opening (where applicable). H suffixes should not be used when ordering (except when non US standards are required) Tubular . Example X S 1 M 1 8 0 0 0 0 1 1 3 3 4 5 6 8 2 8 0 2 P A 3 7 0 * * * D SENSOR TYPE Self Contained SENSING TECHNOLOGY Inductive Proximity Capacitive Proximity BODY TYPE Shielded -- Metal Body Non-shielded -- Metal Body Non-shielded -- Plastic Body TYPE OF ENCLOSURE OR FAMILY Economy D Standard Length -- Threaded Metal CaseM Short Length -- Threaded Metal CaseN Unthreaded Metal CaseL Threaded Plastic CaseP BARREL DIAMETER 4mm Diameter 5mm Diameter 6mm Diameter 8mm Diameter 12mm Diameter 18mm Diameter 30mm Diameter 32mm Diameter MODEL TYPE Analog DC PNP DC NPN DC PNP/NPN, N.O./N.C. (Selectable) DC 2 Wire AC/DC 2 Wire (Universal) OUTPUT MODE N.O. (Normally Open) N.C. (Normally Closed) N.O. + N.C. Complementary N.O. or N.C. Selectable MANUFACTURING CODES X S T 1 2 4 D M N L P AB P N K D M A B C P CONNECTORS Nano (M8) DC OnlyS Micro DC OnlyD Micro AC OnlyK Mini AC or DCA Micro DC PigtailLD Mini AC or DC PigtailLA EXTENDED CABLE LENGTH 5 Meter CableL1 10 Meter CableL2 S D K A LD LA L1 L2 199 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors C G H L T Proximity Sensors Selection Guide Rectangular Selection Guide / Rectangular Description Plastic Shielded Fixed and Adjustable sensing Range Size / Dimensions H x W x D (mm) Nominal Sensing Distance Sn (mm) Fixed Sensing Range Auto Adaptable Adjustable Sensing Range XS7 XS8 J 22x8x8 F 32x15x8 E 26x26x13 C 40x40x15 D 80x80x26 E 26x26x13 C 40x40x15 D 80x80x26 2.5 5 10 15 40 15 25 60 10 - 36 V 100 mA 10 - 36 V 100 mA - - 10 - 36 V 100 mA 10 - 36 V 100 mA - - 10 - 36 V 100 mA 10 - 36 V 100 mA - - 10 - 36 V 100 mA 10 - 36 V 100 mA - - 10 - 36 V 100 mA 10 - 36 V 100 mA - - 10 - 36 V 100 mA - - 20 - 264 V 200 mA 10 - 36 V 200 mA - - 20 - 264 V 300 mA 10 - 36 V 200 mA - - 20 - 264 V 300 mA IP68 IP67 IP68 IP67 IP68 IP67 IP68 IP67 IP68 IP67 IP68 IP67 IP68 IP67 IP68 IP67 Page Number 2 m (6.6') M8 -13F to +158F (-25C to +70C) 208 2 m (6.6') M8 -13F to +158F (-25C to +70C) 208 2 m (6.6') M8/M12 -13F to +158F (-25C to +70C) 208 2 m (6.6') M8/M12 -13F to +158F (-25C to +70C) 208 2 m (6.6') M12 -13F to +158F (-25C to +70C) 208 2 m (6.6') M8/M12/ U20 -13F to +158F (-25C to +70C) 206 2 m (6.6') M8/M12/ U20 -13F to +158F (-25C to +70C) 206 2 m (6.6') M12/U20 -13F to +158F (-25C to +70C) 206 Description Plastic Classic Rectangular Shielded & Non-shielded Supply (Voltage Limits) DC 3 wire Maximum Load DC 2 wire Maximum Load AC/DC 2 wire Maximum Load Enclosure Rating Cable Version Connector Version Connection Proximity Sensors Cable Connector Temperature Rating Size (mm) Nominal Sensing Distance Shielded Sn (mm) Nominal Sensing Distance Non-shielded Sn (mm) Miniature Compact XS5L XSB; XS7,8H; XS7,8G; XS7,8T 8x43 50x76 10x28 26x40 26x26 40x40 1.5 - 2 2 10 15 - 25 3 4 15 20 10 - 30 V 100 mA - - - - - - - - 43x8x8 49x8x8 - - 12 - 58 V 80 mA - - 93 - 264 V 150 mA - - - 76x50x41 10 - 30 V 200 mA - - - - - - - - 28x10x16 - 10 - 30 V 200 mA - - 10 -58 V 200 mA - - 20 -264 V 200 mA 40x12x26 45x12x31 10 - 58 V 200 mA 10 - 58 V 100mA 10 - 58 V 200 mA - - - - 26x26x26 26x26x29 10 - 58 V 200 mA 10 -58 V 100mA 10 - 58 V 200 mA - - - - 40x40x40 40x40x44 Supply (Voltage Limits) DC 3 wire Maximum Load DC 2 wire Maximum Load DC 4 wire Maximum Load AC 2 wire Maximum Load AC/DC 2 wire Maximum Load Dimension (mm) Cable Connector Enclosure Rating Cable Version IP67 - IP67 IP67 IP67 IP67 Connector Version IP67 IP67 - IP67 IP67 IP67 2 m (6.6') M8 -13F to +158F (-25C to +70C) 266 - U78 -13F to +158F (-25C to +70C) 272 2 m (6.6') - -13F to +158F (-25C to +70C) 268 2 m (6.6') M8 -13F to +158F (-25C to +70C) 270 2 m (6.6') M12 -13F to +158F (-25C to +70C) 274 2 m (6.6') M12 -13F to +158F (-25C to +70C) 274 Connection Cable Connector Temperature Rating Page Number 200 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Selection Guide Rectangular and Application Specific Selection Guide / Rectangular and Application Specific Description Plastic Classic Rectangular Shielded & Unshielded Limit switch style Long Range Block XS7/8C XS8 IQ Prox XSD 117x40x40 117x40x40 100x80x40 100x80x40 15 25 40 - 20 25 50 30 - 60 10 - 58 V 200 mA 10 - 58 V 100 mA 10 - 58 V 200 mA 20 - 264 V 350 mA 20 - 264 V 200 mA 19 - 30 V 200 mA - - - - - - - - - - 10 - 58 V 100 mA 10 - 58 V 200 mA 20 - 264 V 500 mA - - - - 10 - 58 V 100 mA 10 - 58 V 200 mA 20 - 264 V 500 mA - - IP67 IP67 IP67 IP67 Page Number 1/2" NPT -13F to +158F (-25C to +70C 276 1/2"NPT -13F to +158F (-25C to +70C 278 1/2" NPT -13F to +158F (-25C to +70C 280 1/2" NPT -13F to +158F (-25C to +70C 282 Description Cylindrical, Rectangular Application Specific Dimension (mm) Nominal Sensing Distance Shielded Sn (mm) Nominal Sensing Distance Non-shielded Sn (mm) DC 3 wire Maximum Load DC 2 wire Maximum Load DC 4 wire Maximum Load AC 2 wire Maximum Load AC/DC 2 wire Maximum Load Proximity Sensors Supply (Voltage Limits) Enclosure Rating Conduit Version Connection Conduit Temperature Rating Selective F,NF, N&NF WFI Size (mm) 18, 30mm Limit Switch Nominal Sensing Distance Shielded Sn (mm) Max. Sn shown Namur Analog Capacitive Magnet Actuated Rotation Control 12, 18mm 4, 5, 6.5, 8, 12, 18, Compact Block Style 30mm Block Style 12, 18, 30mm, F,E,C,D Limit switch 12, 18, 30, 32mm, Limit switch Compact Block Style 30mm Tubular Style E, C 5 - 40 2 -10 0.8 - 40 2 - 60 2 - 15 - 10 -15 10 - 38 V 200 mA 10 - 38 V 200 mA - - - - 20 - 264 V 300 mA 10 - 36 V 250 mA - - 10 -58 V 100 mA 93 -132 V 150 mA - - - - - - 7 -12 V 1.65 mA - - - - 24 V / 48 V - - - 24 V /48 V - - - - - 10 - 38 V 300 mA - - - - 20 -264 V 350 mA - - - - - - 200 V 0.5 A 120 -240 V 0.5 A 130 -200 V 0.5 A 10 - 58 V 200 mA - - - - - - 20 -264 V 0.35 A IP68 IP67 IP67 -13F to +158F (-25C to +70C) 260 IP67 IP67 IP67 -13F to +158F (-25C to +70C) 286 IP64/IP67 - - -13F to +158F (-25C to +70C) 290 IP67 IP67 IP67 -13F to +158F (-25C to +70C) 214, 292 IP63/IP67 - - -13F to +158F (-25C to +70C) 294 IP67 IP67 IP67 -40F to +140F (-40C to +60C) 302 IP67 IP67 - -13F to +158F (-25C to +70C) 216, 284 Supply (Voltage Limits) DC 3 wire Maximum Load DC 4 wire Maximum Load DC 2 wire Maximum Load AC 2 wire Maximum Load AC/DC 2 wire Maximum Load Enclosure Rating Cable Version Connector Version Conduit Entry Temperature Rating Page Number 201 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Selection Guide Cylindrical Selection Guide / Cylindrical Description Metal Fully Shielded Fixed Sensing Range Metal Fully Shielded/Non-Shielded Standard Sensing Range Extended Sensing Range Auto Adaptable Adjustable Range XS5 XS6 XS6 Diameter (mm) 8 12 18 30 8 12 18 30 12 18 30 Nominal Sensing Distance Sn (mm) 1.5 2 5 10 2.5 4 8 15 4 8 15 Supply (Voltage Limits) DC 3 wire 10 - 36 V 10 - 36 V 10 - 36 V 10 - 36 V 10 - 58 V 10 - 58 V 10 - 58 V 10 - 58 V 10 - 36 V 10 - 36 V 10 - 36 V Maximum Load 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 100 mA 100 mA 100 mA Cable M8x33 M12x33 M18x36.5 M30x40.6 M8x50 M12x50 M18x60 M18x60 - - - Connector M8x42 M12x48 M18x48.6 M30x50.7 M8x61 M12x61 M18x72.2 M30x72.2 M12x50 M18x60 M30x60 10 - 58 V 10 - 58 V 10 - 58 V 10 - 58 V - - - - - - - - Dimension (mm) DC 2 wire Maximum Load Dimension (mm) 100 mA 100 mA 100 mA 100 mA - - - - - - Cable M8x50 M12x50 M18x52.5 M30x50 - - - - - - - Connector M8x61 M12x61 M18x64.6 M30x64.2 - - - - - - - Proximity Sensors DC 4 wire - - - - - - - - - - - Maximum Load - - - - - - - - - - - Cable - - - - - - - - - - - Connector - - - - - - - - - - - - - - - - 20 - 264 V 20 - 264 V 20 - 264 V - - - - Dimension (mm) AC/DC 2 wire Maximum Load Dimension (mm) - - - - - 100 mA 100 mA 100 mA - - Cable - - - - - M12x50 M18x60 M30x60 - - - Connector - - - - - M12x61 M18x72.2 M30x72.2 - - - Enclosure Rating Cable IP67 IP68 IP68 IP68 IP67 IP68 IP68 IP68 - - - Connector IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 Cable Version 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') - - - Connector Version M8 M12 M12 M12 M8 M12/U20 M12/U20 M12/U20 - - - Operating Temperature Rating -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) Page Number 212 212 212 212 210 210 210 210 210 210 210 Connection 202 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Selection Guide Cylindrical Selection Guide / Cylindrical Description Plastic Unshielded Metal Shielded/Non-Shielded Fixed Sensing Range Standard Sensing Range Standard Sensing Range (Classic) XS4.P XS1, 2M (N) Nominal Range, Miniature XS1, 2 L(N) Diameter (mm) 8 12 18 30 8 12 18 30 4 5 6.5 Nominal Sensing Distance Shielded Sn (mm) - - - - 1.5 2 5 10 1 1 1.5 Nominal Sensing Distance Unshielded Sn (mm) 2.5 4 8 15 2.5 4 8 15 - - 2.5 DC 3 wire 10 - 38 V 10 - 38 V 10 - 38 V 10 - 38 V 10 -58 V 10 -58 V 10 -58 V 10 -58 V 5 -30 V 5 - 30 V 10 - 38 V Maximum Load 200 mA 200 mA 200 mA 200 mA 100 mA 200 mA 200 mA 200 mA 100 mA 100 mA 200 mA Cable M8x33 M12x33 M18x33 M30x40 M8x50 M12x50 M18x60 M30x60 M4x29 M5x29 M6.5x33 Connector M8x45 M12x45 M18x45 M30x50 M8x61 M12x61 M18x70 M30x70 M4x41 M5x41 M6.5x45 - - - - 10 -58 V 10 -58 V 10 -58 V 10 -58 V - - - Dimension (mm) DC 2 wire Maximum Load - - - - 100 mA 100 mA 100 mA 100 mA - - - Cable - - - - - - - - - - - Connector - - - - - - - - - - - DC 4 wire 10 - 38 V 10 - 38 V 10 - 38 V 10 - 38 V - - - - - - 10 - 38 V Maximum Load 200 mA 200 mA 200 mA 200 mA - - - - - - 200 mA Cable M8x50 M12x50 M18x60 M30x60 - - - - - - M6.5x50 Connector M8x61 M12x61 M18x70 M30x70 - - - - - - - 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V 20 - 264 V - - - Dimension (mm) Dimension (mm) AC/DC 2 wire Maximum Load Dimension (mm) 100 mA 200 mA 200 mA 200 mA 100 mA 200 mA 200 mA 200 mA - - - Cable M8x50 M12x50 M18x60 M30x60 2 m(6.6') 2 m(6.6') 2 m(6.6') 2 m(6.6') - - - Connector M8x61 M12x61 M18x70 M30x70 U20 U20 U20/U78 U20/U78 - - - Enclosure Rating Cable IP67 IP68 IP68 IP68 IP67 IP68 IP68 IP68 IP67 IP67 IP67 Connector IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 Cable 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') 2 m (6.6') Connector M8 / U20 M12/U20 M12/U20 M12/U20 M12/U20 M12/U20 M12/U20 M12/U20 M8 M8 M8/M12 Operating Temperature Rating -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +176F (-25C to +80C) -13F to +176F (-25C to +80C) -13F to +176F (-25C to +80C) -13F to +176F (-25C to +80C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) -13F to +158F (-25C to +70C) Page Number 226 236 240 248 224 232 240 248 218 220 222 Connection 203 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Supply (Voltage Limits) OSICONCEPTTM Proximity Sensors XS Inductive Sensors Auto-Adapable Technology XS Inductive Sensors - Auto-Adapable Technology Principle of Operation OK = GR Osiconcept, Auto-Adaptable Technology is a patented innovation that offers simplified selection and installation. Sn max. Sensor can be flush mounted, non-flush mounted or recessed mounted. A metal background can be placed in immediate proximity of the sensor. OK = GR To set-up, activate adaptable technology by pressing button. When no target is present, the sensor will adapt to the environment, then pass the target in front of the sensor in the usual way. The green LED flashes when sensor is adapting to its environment or learning target location, then becomes steady when sensor is set. After the sensor is programmed it will recognize the target and provide output. Sn max. OK = GR Sn max. NOTE: Follow instruction bulletin provided with Osiconcept Auto-Adaptable product. Fine Adjustment for Precise Positioning Sn Sn Sn Proximity Sensors Fine Adjustment for Precise Positiong Sn Sn Fine Adjustment for Frontal Target Motion Sn The simple process of pressing the self-teach button with the target located in the precise position (lateral movement) across the detector sensing face. This adjustment will only allow the sensor output to change state when the object reaches the precise position in the sensors field. The simple process of pressing the self-teach button with the target located in the precise position (frontal distance) from the detector sensing face. This adjustment will only allow the sensor output to change state when the object reaches the precise position in the sensors field. Installation A full line of support brackets allows for simple and fast installation or maintenance. No tools are necessary, simple clips and the sensor is fixed in position and ready for operation. Brackets available for all sizes J, F, E, C, D in flat and 90. Brackets available for substitution to existing XS*E, XS*C, and XS*D, see page 300. 204 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 OSICONCEPTTM Proximity Sensors XS Inductive Sensors Auto-Adapable Technology XS Inductive Sensors - Auto-Adaptable Technology Flat Dimensions " (mm) Applications Sn - Flush Mounted " (mm) Sn - Non-Flush Mounted " (mm) Product Reference Pages 0.51 x 1.0 x 1.0 (13 x 26 x 26) Size E 1.57 x 1.57 x 0.59 (40 x 40 x 15) 3.14 x 3.14 x 1.0 (80 x 80 x 26) Size C Size D Machine Tooling, Molding, Welding Machinery, and Packaging 0.2-0.39 (5-10) 0.31-0.59 (8-15) 0.2-0.59 (5-15) 0.31-0.98 (8-25) XS8E1A1 XS8CE1A1 206 206 Material Handling, Conveyors 0.78-1.57 (20-40) 0.78-2.36 (20-60) XS8D1A1 206 Dimensions " (mm) 0.47 (12) 0.7 (18) 1.18 (30) Applications Sn - Flush Mounted " (mm) Sn - Non-Flush Mounted " (mm) Product Reference Pages Machining, Food Industry 0.07-0.13 (1.7-3.4) 0.07-0.20 (1.7-5) XS612Bk 210 6.14-0.27 (3.5-7) 0.14-0.40 (3.5-10) XS618Bk 210 0.24-0.47 (6-12) 0.24-0.71 (6-18) XS630Bk 210 Proximity Sensors Cylindrical 205 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved OSICONCEPTTM Proximity Sensors XS8 Auto-Adaptable Inductive Sensor Flat Rectangular, DC and AC/DC XS8 Auto-Adaptable Inductive Sensor / Flat Rectangular, DC and AC/DC Features: * Enhanced sensing distances * Self-adapting to flush or non-flush mounted environments * 3 wire DC and 2 wire AC/DC * Self-teach Nominal Sensing Distance Circuit Type Output Mode Voltage Range Load Current Maximum Operating Frequency Catalog Number DC Size E (13x26x26 mm) 2 m (6.6") cable q XS8 *1A1****L2 15mm PNP N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1PAL2 15mm NPN N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1NAL2 Size E (13x26x26 mm) M8 connector 15mm PNP N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1PAM8 15mm NPN N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1NAM8 Size E (13x26x26 mm) M12 pigtail, 0.1 m 15mm PNP N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1PAL01M12 15mm NPN N.O.* 12-24 Vdc 100 mA 1000 Hz XS8E1A1NAL01M12 Size C (15x40x40 mm) 2 m (6.6') cable q PNP N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1PAL2 25mm NPN N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1NAL2 Size C (15x40x40 mm) M8 connector XS8 E1A1**M8 25mm PNP N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1PAM8 25mm NPN N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1NAM8 Size C (15x40x40 mm) M12 pigtail, 0.1 m 501559_1 25mm PNP N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1PAL01M12 25mm NPN N.O.* 12-24 Vdc 200 mA 1000 Hz XS8C1A1NAL01M12 Size D (26x80x80 mm) 2 m (6.6') cable q 60mm PNP N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1PAL2 60mm NPN N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1NAL2 Size D (26x80x80 mm) M12 connector 60mm PNP N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1PAM12 60mm NPN N.O.* 12-24 Vdc 200 mA 100 Hz XS8D1A1NAM12 24-240 Vac/24-210 Vdc 5 - 200 mA 1000/50 Hz XS8E1A1MAL2 24-240 Vac/24-210 Vdc 5 - 200 mA 1000/50 Hz XS8E1A1MAL01U20 24-240 Vac/24-210 Vdc 5 - 300 mA 1000/50 Hz XS8C1A1MAL2 24-240 Vac/24-210 Vdc 5 - 300 mA 1000/50 Hz XS8C1A1MAL01U20 24-240 Vac/24-210 Vdc 5 - 300 mA 100/50 Hz XS8D1A1MAL2 24-240 Vac/24-210 Vdc 5 - 300 mA 100/50 Hz XS8D1A1MAU20 AC Size E (13x26x26 mm) 2 m (6.6') cable q XS8 E1A1***M8 XS8 C1A1***M8 15mm 15mm N.O.* 2 wire N.O.* Size C (15x40x40 mm) 2 m (6.6') cable q Dimensions 25mm XS8 C/D 25mm B E 2 wire N.O.* Size C (15x40x40 mm) U20 pigtail, 0.1 m XS8E C D 2 wire Size E (13x26x26 mm) U20 pigtail, 0.1 m F 2 wire N.O.* Size D (26x80x80 mm) 2 m (6.6') cable q B 60mm F E B 60mm a q E B 2 wire N.O.* Size D (26x80x80 mm) U20 connector 2 wire N.O.* To order a normally closed (N.C.) version change the A to B, example: XS8C1A1PAL2 to XS8C1A1PBL2. 5m cable length available with L5 suffix / 10m cable length available with L10 suffix. A Minimum Mounting Clearances (mm) e G Proximity Sensors 25mm e H A L2 A B M12 C D E F G H Side by Side E 0.55 0.4 (14) (11) 1.0 (26) 0.5 (13) 0.3 0.8 (8.8) (20) 0.1 0.26 0.25 (3.5) (6.8) (6.6) C 0.55 0.4 (14) (11) 1.6 (40) 0.6 (15) 0.4 1.3 (9.8) (33) 0.1 0.32 0.53 (4.5) (8.3) (13.6) D 0.9 (23) 3.1 (80) 1.0 (26) 0.6 (16) 0.2 0.33 1.5 (5.5) (8.5) (37.8) 0.5 (14) 2.5 (65) XS8E XS8C XS8D e 1.6 (40) e 2.4 (60) e 7.9 (200) Face to Face e 5.9 (150) e 4.9 (125) e 23.6 (600) e 3.1 (80) e 4.7 (120) e 15.7 (400) e 11.8 (300) e 9.8 (250) inches (mm) 206 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 OSICONCEPTTM Proximity Sensors XS8 Auto-Adaptable Inductive Sensor Flat Rectangular, DC and AC/DC XS8 Auto-Adaptable Inductive Sensor / Flat Rectangular, DC and AC/DC Specifications Connector M8 M12 4 4 1 Mechanical 0.5" 20-UNF 1 3 3 1 2 2 3 Sn PNP/M12 or M8 Cable Blue Brown Black Fine Detection Zone BU - BN + BK Output BU/3 BK/4 (NO) BK/2 (NC) - BU/3 NPN/M12 or M8 BN/1 NPN + BN/1 PNP Type 2 Wire 0.5" 20-UNF + BK/4 (NO) BK/2 (NC) - BN/2 BU/3 M8 connector, N.O. and N.C. to to pin 4. Temperature Range Enclosure Rating Shielded Non-shielded XS8E 5 - 10 mm 5 - 15 mm XS8C 8 - 15 mm 8 - 25 mm XS8D 20 - 40 mm 20 - 60 mm XS8E 0 - 10 mm 0 - 15 mm XS8C 0 - 15 mm 0 - 25 mm XS8D 0 - 40 mm 0 - 60 mm Storage -40 to +185 F (-40 to +85 C) Operation -13 to +158 F (-25 to +70 C) NEMA Type 1, 4X,12 IEC Type IP68 cable version / IP67 connector version Vibration 25 g, amplitude +/- 2mm (f=10-55 Hz) Shock Resistance 50 g duration 11ms Differential (%of Sr) 1 - 15% Repeatability (% of Sr) LED Indicator 2% Output Yellow Power & Teach Green Enclosure material PBT Cable PVR 3x0.34mm2 Connector M8 Nano 3pin, M12 Micro 4pin, U20 Micro 3pin Electrical 2 wire AC/DC 3 wire DC Voltage Range 24 - 240 Vac/24 - 210 V dc 12 - 24 Vdc Voltage Limit (including ripple) 20 - 264 Vac/dc 10 - 36 Vdc Voltage Drop 5.5 V 2V XS8E 5. . .200 mA 100 mA XS8C DC:5. . .300 mA/AC:5. . .260 mA 200 mA XS8D DC:5. . .300 mA/AC:5. . .260 mA 200 mA Load Current Maximum (max.) Leakage (Residual) Current-open state 1.5 mA - Current consumption - 10 mA XS8E 10 ms 5 ms XS8C 10 ms 5 ms XS8D 15 ms 10 ms XS8E 0.3 ms 0.3 ms XS8C 0.3 ms 0.3 ms XS8D 0.3 ms 0.3 ms XS8E 0.7 ms 0.7 ms XS8C 0.7 ms 0.7 ms XS8D 5 ms 5 ms Short Circuit Protection No Yes Overload Protection No Yes Power up Delay (max.) On Delay (max.) Off Delay (max.) Protective Circuitry Proximity Sensors Wiring Agency Listings (R) Connector Cables (M8 or S suffix; M12 or D suffix; U20 or K suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 207 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS7 Inductive Sensor Flat Rectangular, DC XS7 Inductive Sensor / Flat Rectangular, DC 501549_1 Features: Entire range of flat proximity sensors dedicated to OEM's and their applications. * Complete flat range offering. * 2 and 3 wire DC * Normally Open or Normally Closed outputs available XS7 J1A1**L2 * Cable and connector versions * PNP or NPN Nominal Sensing Distance XS7 FA1**L01M8 Circuit Type Output Mode Voltage Range Load Current Maximum Operating Frequency Catalog Number Size J (8x8x22 mm) 2 m (6.6') cable q 2.5 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 4000 Hz XS7J1A1DAL2 2.5 mm PNP N.O.a 12-24 Vdc 100 mA 2000 Hz XS7J1A1PAL2 2.5 mm NPN N.O.a 12-24 Vdc 100 mA 2000 Hz XS7J1A1NAL2 Size J (8x8x22 mm) M8 pigtail, 0.1 m 2.5 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 4000 Hz XS7J1A1DAL01M8 2.5 mm PNP N.O.a 12-24 Vdc 100 mA 2000 Hz XS7J1A1PAL01M8 2.5 mm NPN N.O.a 12-24 Vdc 100 mA 2000 Hz XS7J1A1NAL01M8 Size F (8x15x32 mm) 2 m (6.6') cable q XS7 D1A1**M12 5 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 5000 Hz XS7F1A1DAL2 5 mm PNP N.O.a 12-24 Vdc 100 mA 2000 Hz XS7F1A1PAL2 5 mm NPN N.O.a 12-24 Vdc 100 mA 2000 Hz XS7F1A1NAL2 Size F (8x15x32 mm) M8 pigtail, 0.1 m Dimensions 5 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 5000 Hz XS7F1A1DAL01M8 5 mm PNP N.O.a 12-24 Vdc 100 mA 2000 Hz XS7F1A1PAL01M8 5 mm NPN N.O.a 12-24 Vdc 100 mA 2000 Hz XS7F1A1NAL01M8 Size E (13x26x26 mm) 2m (6.6') cable q XS7 C/D XS7E B C D E F 10 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 1000 Hz XS7E1A1DAL2 10 mm PNP N.O.a 12-24 Vdc 100 mA 1000 Hz XS7E1A1PAL2 10 mm NPN N.O.a 12-24 Vdc 100 mA 1000 Hz XS7E1A1NAL2 E B Size E (13x26x26 mm) M8 connector B E B F E A XS7 E A L2 A M12 B C D E F 0.55 (14) 0.4 (11) 1.0 (26) 0.5 (13) 0.3 (8.8) 0.8 (20) 0.1 (3.5) XS7 C 0.55 (14) 0.4 (11) 1.6 (40) 0.6 (15) 0.4 (9.8) 1.3 (33) 0.1 (4.5) XS7 D 0.9 (23) 0.5 (14) 3.1 (80) 1.0 (26) 0.6 (16) 2.5 (65) 0.2 (5.5) XS7 F XS7J 0.6 (15) 0.3 (8) 0.3 9 0.6 (16) O4 O3 inches (mm) Dual Dimensions inches mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 1000 Hz XS7E1A1DAM8 10 mm PNP N.O.a 12-24 Vdc 100 mA 1000 Hz XS7E1A1PAM8 10 mm NPN N.O.a 12-24 Vdc 100 mA 1000 Hz XS7E1A1NAM8 10 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 1000 Hz XS7E1A1DAL01M12 10 mm PNP N.O.a 12-24 Vdc 100 mA 1000 Hz XS7E1A1PAL01M12 10 mm NPN N.O.a 12-24 Vdc 100 mA 1000 Hz XS7E1A1NAL01M12 Size C (15x40x40 mm) 2 m (6.6') cable q 15 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 1000 Hz XS7C1A1DAL2 15 mm PNP N.O.a 12-24 Vdc 100 mA 1000 Hz XS7C1A1PAL2 15 mm NPN N.O.a 12-24 Vdc 100 mA 1000 Hz XS7C1A1NAL2 Size C (15x40x40 mm) M8 connector 15 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 1000 Hz XS7C1A1DAM8 15 mm PNP N.O.a 12-24 Vdc 100 mA 1000 Hz XS7C1A1PAM8 15 mm NPN N.O.a 12-24 Vdc 100 mA 1000 Hz XS7C1A1NAM8 Size C (15x40x40 mm) M12 pigtail, 0.1 m 4 0.3 8 0.8 (22) 0.3 8 10 mm Size E (13x26x26 mm) M12 pigtail, 0.1 m B 1.2 (32) Proximity Sensors XS7 1A1**L2 O3 15 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 1000 Hz XS7C1A1DAL01M12 15 mm PNP N.O.a 12-24 Vdc 100 mA 1000 Hz XS7C1A1PAL01M12 15 mm NPN N.O.a 12-24 Vdc 100 mA 1000 Hz XS7C1A1NAL01M12 Size D (26x80x80 mm) 2 m (6.6') cable q 40 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 100 Hz XS7D1A1DAL2 40 mm PNP N.O.a 12-24 Vdc 100 mA 100 Hz XS7D1A1PAL2 40 mm NPN N.O.a 12-24 Vdc 100 mA 100 Hz XS7D1A1NAL2 Size D (26x80x80 mm) M12 connector 40 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 100 Hz XS7D1A1CAM12 40 mm 2 wire N.O.a 12-24 Vdc 1.5 - 100 mA 100 Hz XS7D1A1DAM12 40 mm PNP N.O.a 12-24 Vdc 100 mA 100 Hz XS7D1A1PAM12 40 mm NPN N.O.a 12-24 Vdc 100 mA 100 Hz XS7D1A1NAM12 a q To order a normally closed (N.C.) version change the A to B, example: XS718B1PAL2 to XS718B1PBL2. 0.8m and 0.15m pigtail length available on 2 wire E and C. 5m cable length available with L5 suffix / 10m cable length available with L10 suffix. 208 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS7 Inductive Sensor Flat Rectangular, DC XS7 Inductive Sensor / Flat Rectangular, DC Specifications Wiring Connector M12 4 3 4 1 1 Cable M8 3 2 Blue Brown Black Usable Sensing Range BU - BN + BK Output Temperature Range PNP/M12 or M8 NPN/M12 or M8 + BN/1 PNP BK/4 (NO) BK/2 (NC) - BU/3 + BN/1 NPN BK/4 (NO) BK/2 (NC) - BU/3 M8 connector, N.O. and N.C. to pin 4. 2 Wire N.C. 2 Wire N.O. BN/3 BN/1 +/- BU/4 -/+ NO NC BU/2 (M12) BU/4 (M8) +/-/+ Cable Connector M8 4 1 BN/1 Blue Brown Black 3 BU - BN + BK Output XS7J, XS7F + BK/4 - BU/3 BN/3 BN/1 +/- BU/4 -/+ BN/1 BU/2 -40 to +185 F (-40 to +85 C) Operational -13 to +158 F (-25 to +70 C) NEMA Type 1,4X,12 IEC Type IP68 Cable version / IP67 Connector version 1-15% Repeatability (% of Sr) 2% LED Indicator Yellow output Enclosure Material PBT Cable PVR, 3x0.34mm2 Connector Nano conn. 3 pin M8 / Micro conn. 4 pin M12 Electrical 2 wire 3 wire Voltage Range 12 - 24 Vdc 12 - 24 Vdc Voltage Limit (including ripple) 10 - 36 Vdc 10 - 36 Vdc Voltage Drop 2V 4V Current Limit Maximum 100 mA 100 mA Current consumption 0.5 mA 10 mA XS7J 10 ms 5 ms XS7F 5 ms 5 ms XS7E 5 ms 10 ms XS7C 5 ms 5 ms XS7D 10 ms 30 ms XS7J 0.5 ms 0.1 ms XS7F 0.5ms 0.1 ms XS7E 0.3 ms 2 ms XS7C 0.3 ms 2 ms XS7D 10 ms 5 ms XS7J 1 ms 0.1 ms XS7F 5 ms 0.1 ms XS7E 0.7 ms 6 ms XS7C 0.7 ms 5 ms XS7D 10 ms 15 ms Short Circuit Protection Yes Yes Overload Protection Yes Yes +/On Delay (max.) NC NO 0 - 32 mm Storage 50 g duration 11ms 2 Wire N.C. 2 Wire N.O. 0 - 12 mm XS7D Differential (%of Sr) - BU/3 0 - 8 mm XS7C 25 g, amplitude +/- 2mm (f=10-55 Hz) Power up Delay (max.) BK/4 0 - 4 mm XS7E Shock Resistance + BN/1 NPN 0 - 2 mm XS7F Vibration NPN N.O. or N.C. PNP N.O. or N.C. BN/1 PNP Enclosure Rating XS7J -/+ Off Delay (max.) Protective Circuitry Agency Listings (R) Proximity Sensors Mechanical XS7E, XS7C, XS7D E164869 CCN NRKH Minimum Mounting Clearances (mm) e e XS7E XS7C XS7D e Side by Side Face to Face Face to Metal Object e 0.2 (4) e 0.4 (10) e 0.8 (20) e 0.9 (24) e 2.4 (60) e 4.7 (120) e 0.2 (6) e 0.6 (15) e 1.2 (30) e XS7J XS7F e e Side by Side Face to Face Face to Metal Object e 0.03 (1) e 0.8(020) e 0.2 (6) e 0.4(12) e 0.08 (2) e 0.12 (3) Connector Cables (M8 or S suffix; M12 or D suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 209 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved OSICONCEPTTM Proximity Sensors XS6 Extended Range and Auto-Adaptable Inductive Sensor Metal Tubular, DC and AC/DC XS6 Extended Range Inductive Sensor / Metal Tubular, DC and AC/DC 801267 thread M8x1 thread M12x1 XS6 **B1**L2 thread M18x1 thread M30x1.5 XS6 **B1**M12 Features: Entire range of fully shielded metal body cylindrical inductive proximity sensors. * * * * * * Increased sensing range, fully shielded 2 wire AC/DC and 3 wire DC Normally Open or Normally Closed outputs available Cable and connector versions PNP or NPN, DC Self-Teach available on 12-30mm versions Output Mode Voltage Range Load Current Max. Operating Frequency DC AC Catalog Number N.O.a N.O.a 12-48 Vdc 12-48 Vdc 200 mA 200 mA 5000 Hz 5000 Hz - - XS608B1PAL2 XS608B1NAL2 N.O.a N.O.a 12 mm Diameter, 2 m (6.6') cable q 4 mm 2 wire N.O.a 4 mm PNP N.O.a 4 mm NPN N.O.a 12-48 Vdc 12-48 Vdc 200 mA 200 mA 5000 Hz 5000 Hz - - XS608B1PAM12 XS608B1NAM12 12-48 Vdc 12-48 Vdc 12-48 Vdc 1.5-100 mA 200 mA 200 mA 4000 Hz 5000 Hz 5000 Hz 25 Hz - - XS612B1MAL2 XS612B1PAL2 XS612B1NAL2 24-240 Vac/24-210 Vdc 1.5-100 mA 12-48 Vdc 200 mA 12-48 Vdc 200 mA 4000 Hz 5000 Hz 5000 Hz 25 Hz - - XS612B1MAU20 XS612B1PAM12 XS612B1NAM12 24-240 Vac/24-210 Vdc 1.5-100 mA 12-48 Vdc 200 mA 12-48 Vdc 200 mA 3000 Hz 2000 Hz 2000 Hz 25 Hz - - XS618B1MAL2 XS618B1PAL2 XS618B1NAL2 24-240 Vac/24-210 Vdc 1.5-100 mA 12-48 Vdc 200 mA 12-48 Vdc 200 mA 3000 Hz 2000 Hz 2000 Hz 25 Hz - - XS618B1MAU20 XS618B1PAM12 XS618B1NAM12 24-240 Vac/24-210 Vdc 1.5-100 mA 12-48 Vdc 200 mA 12-48 Vdc 200 mA 2000 Hz 1000 Hz 1000 Hz 25 Hz - - XS630B1MAL2 XS630B1PAL2 XS630B1NAL2 24-240 Vac/24-210 Vdc 1.5-100 mA 12-48 Vdc 200 mA 12-48 Vdc 200 mA 2000 Hz 1000 Hz 1000 Hz 25 Hz - - XS630B1MAU20 XS630B1PAM12 XS630B1NAM12 100 mA 100 mA 1000 Hz 1000 Hz - - XS612B2PAL01M12 XS612B2NAL01M12 100 mA 100 mA 1000 Hz 1000 Hz - - XS618B2PAL01M12 XS618B2NAL01M12 100 mA 100 mA 1000 Hz 1000 Hz - - XS630B2PAL01M12 XS630B2NAL01M12 Nominal Sensing Distance 8 mm Diameter, 2 m (6.6') cable q 2.5 mm 2.5 mm Dimensions PNP NPN 8 mm Diameter, M12 connector 2.5 mm 2.5 mm b c a a PNP NPN 12 mm Diameter, M12 connector Connector b b 8 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (40) 12 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (42) 18 2.3 (60) 0.09 (51) 2.8 (72.2) 2.0 (51) 30 2.3 (60) 0.09 (51) 2.8 (72.2) 2.0 (51) 4 mm 4 mm 4 mm 2 wire PNP NPN N.O.a N.O.a N.O.a 18 mm Diameter, 2 m (6.6') cable q 8 mm 2 wire N.O.a 8 mm PNP N.O.a 8 mm NPN N.O.a 18 mm Diameter, M12 connector 8 mm 8 mm 8 mm N.O.a N.O.a N.O.a 30 mm Diameter, 2m (6.6') cable q 15 mm 2 wire N.O.a 15 mm PNP N.O.a 15 mm NPN N.O.a 520030 inches (mm) 2 wire PNP NPN 30 mm Diameter, M12 connector 15 mm 15 mm 15 mm 2 wire PNP NPN N.O.a N.O.a N.O.a Self - Teach version (Auto-Adaptable) 12 mm Diameter, M12 connector pigtail 0.1m 5 mm 5 mm XS6**B2**L01M12 PNP NPN N.O.a N.O.a 12-24 Vdc 12-24 Vdc 18 mm Diameter, M12 connector pigtail 0.1m 9 mm 9 mm Dimensions PNP NPN N.O.a N.O.a 12-24 Vdc 12-24 Vdc 30 mm Diameter, M12 connector pigtail 0.1m 20 15 mm 15 mm b 2.44 62 M12 Proximity Sensors Cable a Circuit Type c a b c 12 1.9 (50) 1.4 (37) 0.2 (5) 18 2.3 (60) 1.5 (38.5) 0.31 (8) 30 29.9 (760) 1.5 (38.5) N.O.a N.O.a 12-24 Vdc 12-24 Vdc To order a normally closed (N.C.) version change the A to B, example: XS518B1PAL2 to XS518B1PBL2. Self-teach version only 5m cable length available with L5 suffix / 10m cable length available with L10 suffix. XS Minimum Mounting Clearances " (mm) Connector M12 a a q PNP NPN Auto-Adaptable Extended Range e e e e e 0.5 (13) inches (mm) - 12 18 30 Dual Dimensions inches mm Side by Side Flush e 0.55 (14) e 1.1 (28) e 1.9 (48) Not Flush 1.9 (50) 3.9 (100) 7.1 (180) Face to Face Flush Not Flush e 1.9 (50) 3.9 (100) e 3.9 (100) 7.9 (200) e 7.1 (180) 14.1 (360) 8 12 18 30 Side by Side e 0.1 (3) e 0.2 (4) e 0.4 (10) e 0.8 (20) Face to Face e 0.7 (18) e 0.9 (24) e 2.4 (60) e 4.7 (120) Face to Metal Object e 0.17 (4.5) e 0.2 (6) e 0.6 (15) e 1.2 (30) 6 Extended Range Inductive Sensor / Metal Tubular, DC and 210 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 OSICONCEPTTM Proximity Sensors XS6 Extended Range and Auto-Adaptable Inductive Sensor Metal Tubular, DC and AC/DC Specifications Mechanical Extended Range 3 Wire Selectable Cable Connector M12 4 Fine Detection Zone 3 1 Blue Brown Black 2 PNP Sn NPN + BN/1 PNP BK/4 (NO) BK/2 (NC) - BU/3 + BN/1 NPN BK/4 (NO) BK/2 (NC) Temperature Range - BU/3 Enclosure Rating Cable Connector M12 4 BU - BN + BK Output 3 1 Blue Brown Black 2 BU - BN + BK Output Enclosure Material NPN PNP 1 BN PNP BK 3 + Max. Tightening Torque 1 BN NPN BK 3 BU 4 BU - + 4 - 2 Wire AC/DC Connector U20 1 2 Blue Brown Black 3 BU - BN + BK Output 2 Wire Non-Polarized BN/2 BU/3 Non-shielded 0 - 2 mm - - 12 mm 0 - 3.2 mm 1.7 - 3.4 mm 1.7 - 5 mm 18 mm 0 - 6.4 mm 3.5 - 6 mm 3.5 - 9 mm 30 mm 0 - 12 mm 6 - 12 mm 6 - 18 mm 12 mm - 0 - 3.4 mm 0 - 5 mm 18 mm - 0 - 6 mm 0 - 9 mm 30 mm - 0 - 12 mm 0 - 18 mm Storage -40 to +185 F (-40 to +85 C) Operation -13 to +158 F (-25 to +70 C) NEMA Type 3,4X,6P,12,13 IEC Type IP68 cable versions (IP67 connector versions) Case Nickel Plated Brass Face PBT 08 mm 9 N*m (6.7 lb-ft) 12 mm 15 N*m (11 lb-ft) 18 mm 35 N*m (26 lb-ft) 30 mm 50 N*m (37 lb-ft) Vibration 25 g, amplitude +/- 2mm (f=10-55 Hz) Shock Resistance 50 g duration 11ms Differential (%of Sr) 15% LED Indicator - Output Yellow Green PVR 3x0.34 mm 2/PVR2x0.5 mm2 PVR - 4.2 mm O.D. Connector M12 4 pin / U20 3 pin Micro conn. M12 Micro conn. 4 pin Electrical 2 wire AC/DC 3 wire DC Auto-adaptable DC Voltage Range 24-240 Vac; 24-210 Vdc 12 - 48 Vdc 12 - 24 Vdc Voltage Limit (including ripple) 20-264 Vac/dc 10 - 58 Vdc 10 - 36 Vdc Voltage Drop 5.5 V 2V 2V (max.) Leakage (Residual) Current-open state 0.8 mA - - Current consumption - 10 mA 10 mA Maximum Current Limit AC: 5. . .300 mA / DC: 5. . . 200 mA 200 mA 100 mA Power up Delay (max.) 20 ms-12 mm / 25 ms-18/30 mm 5 ms 5ms 08mm - 0.2 ms - 12mm 0.5 ms 0.2 ms 0.3 ms 18mm 0.5 ms 0.3 ms 0.3 ms 30mm 0.5 ms 0.6 ms 0.3 ms 08mm - 0.2 ms - 12mm 0.2 ms 0.2 ms 0.7 ms 18mm 0.5 ms 0.7 ms 0.7 ms 30mm 2 ms 1.4 ms 0.7 ms 08mm - 2500 Hz - 12mm AC: 25 Hz / DC: 1000 Hz 2500 Hz 1000 Hz 18mm AC: 25 Hz / DC: 1000 Hz 1000 Hz 1000 Hz 30mm AC: 25 Hz / DC: 500 Hz 500 Hz 1000 Hz Short Circuit Protection No Yes Yes Overload Protection Yes Yes Yes Reverse Polarity Protection Yes Yes Off Delay (max.) Maximum Operating Frequency Protective Circuitry XSZBPM12 3% Power & Teach Cable On Delay (max.) XSZB1kk Shielded 08 mm Repeatability (% of Sr) Cable Auto-Adaptable Yes Agency Listings (R) Accessories Description Catalog Number Mounting bracket for teach connector XSZBPM12 Connector Cables (M12 or D suffix; U20 or K suffix) 8mm tubular mounting bracket XSZB108 12mm tubular mounting bracket XSZB112 XSZCD101Y Micro Conn., 4 pin, 2 m, straight 18mm tubular mounting bracket XSZB118 XSZCD111Y Micro Conn., 4 pin, 2 m, 90 30mm tubular mounting bracket XSZB130 XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 211 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Wiring Proximity Sensors XS5 Inductive Sensor Metal Tubular, DC XS5 Inductive Sensor / Metal Tubular, DC 801267 thread M8x1 Features: Complete range of cylindrical proximity sensors dedicated to OEM's and their applications. * Low cost shielded cylindrical inductive proximity sensors thread M12x1 XS5 **B1**L2 * 2 and 3 wire DC * Normally Open or Normally Closed outputs available * Cable and connector versions thread M18x1 * PNP or NPN Nominal Sensing Distance thread M30x1.5 XS5 **B1**M12 Circuit Type Output Mode Voltage Range Load Current Maximum Operating Frequency Catalog Number 8 mm Diameter, 2 m (6.6') cable q 1.5 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 4000 Hz XS508B1DAL2 1.5 mm PNP N.O.a 12-24 Vdc 200 mA 5000 Hz XS508B1PAL2 1.5 mm NPN N.O.a 12-24 Vdc 200 mA 5000 Hz XS508B1NAL2 8 mm Diameter, M12 connector 1.5 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 4000 Hz XS508B1DAM12 1.5 mm PNP N.O.a 12-24 Vdc 200 mA 5000 Hz XS508B1PAM12 1.5 mm NPN N.O.a 12-24 Vdc 200 mA 5000 Hz XS508B1NAM12 12 mm Diameter, 2 m (6.6') cable q Dimensions Proximity Sensors 2 Wire 2 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 4000 Hz XS512B1DAL2 2 mm PNP N.O.a 12-24 Vdc 200 mA 5000 Hz XS512B1PAL2 2 mm NPN N.O.a 12-24 Vdc 200 mA 5000 Hz XS512B1NAL2 12 mm Diameter, M12 connector 2 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 4000 Hz XS512B1DAM12 b 2 mm PNP N.O.a 12-24 Vdc 200 mA 5000 Hz XS512B1PAM12 a 2 mm NPN N.O.a 12-24 Vdc 200 mA 5000 Hz XS512B1NAM12 18 mm Diameter, 2 m (6.6') cable q Cable a Connector b a b 5 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 3000 Hz XS518B1DAL2 5 mm PNP N.O.a 12-24 Vdc 200 mA 2000 Hz XS518B1PAL2 5 mm NPN N.O.a 12-24 Vdc 200 mA 2000 Hz XS518B1NAL2 8 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (40) 12 1.9 (50) 1.6 (42) 2.4 (61) 1.6 (40) 5 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 3000 Hz XS518B1DAM12 18 2.0 (52.5) 1.7 (44) 2.5 (64.6) 1.7 (44) 5 mm PNP N.O.a 12-24 Vdc 200 mA 2000 Hz XS518B1PAM12 30 1.9 (50) 1.6 (42) 2.5 (64.2) 1.6 (41) 5 mm NPN N.O.a 12-24 Vdc 200 mA 2000 Hz XS518B1NAM12 30 mm Diameter, 2 m (6.6') cable q 3 Wire Cable 8 18 mm Diameter, M12 connector 10 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 2000 Hz XS530B1DAL2 10 mm PNP N.O.a 12-24 Vdc 200 mA 1000 Hz XS530B1PAL2 10 mm NPN N.O.a 12-24 Vdc 200 mA 1000 Hz XS530B1NAL2 b 30 mm Diameter, M12 connector a 10 mm 2 wire N.O.a 12-48 Vdc 1.5-100 mA 2000 Hz XS530B1DAM12 10 mm PNP N.O.a 12-24 Vdc 200 mA 1000 Hz XS530B1PAM12 10 mm NPN N.O.a 12-24 Vdc 200 mA 1000 Hz XS530B1NAM12 Connector a b a 1.3 (33) 1.0 (25) 1.6 (42) b 1.0 (26) 12 1.3 (33) 1.0 (25) 1.9 (48) 18 1.4 (36.5) 1.1 (28) 1.9 (48.6) 1.1 (28) 30 1.6 (40.6) 1.2 (32) 2.0 (50.7) 1.3 (32) 1.1 (29) a q To order a normally closed (N.C.) version change the A to B, example: XS518B1PAL2 to XS518B1PBL2. 5m cable length available with L5 suffix / 10m cable length available with L10 suffix. XS Minimum Mounting Clearances (mm) e inches (mm) e e 8 12 18 30 Side by Side e 0.11 (3) e 0.15 (4) e 0.4 (10) e 0.8 (20) Face to Face e 0.7 (18) e 0.9 (24) e 2.4 (60) e 4.7 (120) Facing a Metal Object e 0.17 (4.5) e 0.2 (6) e 0.6 (15) e 1.2 (30) Dual Dimensions inches mm 212 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS5 Inductive Sensor Metal Tubular, DC XS5 Inductive Sensor / Metal Tubular, DC Specifications Wiring Connector M12 4 1 Usable Sensing Range Cable 3 Blue Brown 2 BU - BN + Temperature Range 2 Wire Non Polarized BN/2 BU/3 Enclosure Rating +/- Enclosure Material +/- 3 Wire Connector 4 1 4 3 3 1 M8 2 M12 Max. Tightening Torque Cable Blue Brown Black BU - BN + BK Output NPN PNP + BN/1 PNP BK/4 (NO) BK/2 (NC) - BU/3 BN/1 NPN + BK/4 (NO) BK/2 (NC) BU/3 - 08mm 0 - 1.2 mm 12mm 0 - 1.6 mm 18mm 0 - 4 mm 30mm 0 - 8 mm Storage -40 to +185 F (-40 to +85 C) Operation -13 to +158 F (-25 to +70 C) NEMA Type 3,4X,6P,12,13 IEC Type IP68 cable version (except 8mm and connector version: IP67) Case Nickel Plated Brass Face PBT 08mm 5 N*m (3.7 lb-ft) 12mm 6 N*m (4.4 lb-ft) 18mm 15 N*m (11 lb-ft) 30mm 40 N*m (29.5 lb-ft) Vibration 25 g, amplitude +/- 2 mm (f=10-50 Hz) Shock Resistance 50 g duration 11 ms Differential (%of Sr) 15% Repeatability (% of Sr) 3% LED Indicator Output status Cable PVR 2x0.5 mm2 PVR 3x0.34 mm2 Connector M12 4pin M8 3 pin / M12 4pin Electrical 2 wire 3 wire Voltage Range 12 - 48 Vdc 12 - 24 Vdc Voltage Limit (including ripple) 10 - 58 Vdc 10 - 36 Vdc Voltage Drop 4V 2V Maximum Load Current 1.5 ...100 mA 200 mA (max.) Leakage (Residual) Current-open state 0.5mA - Current consumption - 10 mA Power up Delay (max.) 5 ms 5 ms 08mm 0.2 ms 0.1 ms 12mm 0.2 ms 0.1 ms 18mm 0.2 ms 0.15 ms 30mm 0.3 ms 0.2 ms 08mm 0.2 ms 0.1 ms 12mm 0.2 ms 0.1 ms 18mm 0.2 ms 0.35 ms 30mm 0.3 ms 0.7 ms Short Circuit Protection Yes Yes Overload Protection Yes Yes On Delay (max.) Off Delay (max.) Protective Circuitry Radio Frequency Immunity (RFI) IEC 61000-4-3 Level 3 IEC 61000-4-3 Level 3 Reverse Polarity Protection Yes UL Agency Listings Yes CSA Proximity Sensors Mechanical 2 Wire CE (R) Accessories Description Catalog Numbers 8mm tubular mounting bracket XSZB108 12mm tubular mounting bracket XSZB112 18mm tubular mounting bracket XSZB118 30mm tubular mounting bracket XSZB130 XSZB1kk Connector Cables (M8 or S suffix; M12 or D suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 213 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved OSICONCEPTTM Proximity Sensors XS9 Application Specific Inductive Sensor Flat Rectangular Analog Output, DC XS9 Application Specific Inductive Sensor / Flat Rectangular Analog Output, DC Features: * DC output current is directly proportional to the target distance * Four sizes: F (8x15x32); E (13x26x26); C (15x40x40); and D (26x80x80) * Cable and connector versions XS9F111kkkL2 XS9E111kkkL2 Nominal Sensing Distance Circuit Type Voltage Range Output Operating Frequency Catalog Number Size F (8x15x32) 2 m(6.6') cable q 5 mm 3 wire 12-24 Vdc 1-10 V 2000 Hz XS9F111A1L2 5 mm 3 wire 12-24 Vdc 4-20 mA 2000 Hz XS9F111A2L2 Size F (8x15x32) M8 connector pigtail 0.1 m 5 mm 3 wire 12-24 Vdc 1-10 V 2000 Hz XS9F111A1L01M8 5 mm 3 wire 12-24 Vdc 4-20 mA 2000 Hz XS9F111A2L01M8 Size E (13x26x26) 2m (6.6') cable q 10 mm 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9E111A1L2 10 mm 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9E111A2L2 Size E (13x26x26) M12 connector pigtail 0.1 m 10 mm XS9D111kkkL2 10 mm Call your local field sales office for availability! 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9E111A1L01M12 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9E111A2L01M12 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9C111A1L2 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9C111A2L2 Size C (15x40x40) 2 m (6.6') cable q 15 mm 15 mm Size C (15x40x40) M12 connector pigtail 0.1 m XS9 F XS9E 0.6 (15) 0.3 9 3 wire 12-24 Vdc 1-10 V 1000 Hz XS9C111A1L01M12 3 wire 12-24 Vdc 4-20 mA 1000 Hz XS9C111A2L01M12 3 wire 12-24 Vdc 1-10 V 100 Hz XS9D111A1L2 3 wire 12-24 Vdc 4-20 mA 100 Hz XS9D111A2L2 12-24 Vdc 1-10 V 100 Hz XS9D111A1M12 100 Hz XS9D111A2M12 Size D (26x80x80) 2 m (6.6') cable q 40 mm 1.2 (32) B 0.3 8 15 mm 15 mm 40 mm F Size D (26x80x80) M12 connector 40 mm 3 wire 40 mm 3 wire 12-24 Vdc 4-20 mA q 5m cable length available with L5 suffix / 10m cable length available with L10 suffix. E B XS Minimum Mounting Clearances " (mm) O3 e e e XS9C/D C B D E F XS9F XS9E XS9C XS9D Side by Side Face to Face Face to Metal Object e 0.08 (2) e 0.16 (4) e 0.40 (10) e 0.8 (20) e 0.47 (12) e 0.9 (24) e 2.3 (60) e 4.7 (120) e 0.12 (3) e 0.23 (6) e 0.6 (15) e 1.2 (30) A E B Proximity Sensors Dimensions A L2 A M12 B E 0.55 (14) - C 0.55 (14) D 0.9 (23) C D E F 1.0 (26) 0.5 (13) 0.3 (8.8) 0.8 (20) 0.1 (3.5) - 1.6 (40) 0.6 (15) 0.4 (9.8) 1.3 (33) 0.1 (4.5) 0.5 (14) 3.1 (80) 1.0 (26) 0.6 (16) 2.5 (65) 0.2 (5.5) inches (mm) Dual Dimensions inches mm 214 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 OSICONCEPTTM Proximity Sensors XS9 Application Specific Inductive Sensor Flat Rectangular Analog Output, DC XS9 Application Specific Inductive Sensor / Flat Rectangular Analog Output, DC Specifications Wiring Mechanical 4 4 1 Cable 3 3 1 2 Blue Brown Black Usable Sensing Range BU - BN + BK Output Temperature Range 3 Wire (0 - 10 V) BN/1 mA + BK/4 Enclosure Rating Is Output Voltage R BU/3 U=R.Is - 2 Wire (4 - 20 mA) BN/1 mA + Output Current BK/4 U=R.Is R BU/3 - Is XS9F 1...5 mm XS9E 1...10 mm XS9C 2...15 mm XS9D 5...40 mm Storage -40 to +185 F (-40 to +85 C) Operation -13 to +158 F (-25 to +70 C) NEMA Type 1, 4X (indoor only) 12 IEC Type IP68 cable version / IP67 connector version Vibration 25 g, amplitude +/-2 mm (f=10 to 55 Hz) Shock 50 g, duration 11 ms Enclosure material PBT Cable PVR 3x0.34 mm2 Connector M8 Nano conn. 3 pin / M12 Micro conn. 4 pin Electrical 2 wire DC Voltage Range 12 - 24 Vdc Voltage Limit (including ripple) 10 - 36 Vdc Max. output current drift with the rated operating temperature <10% Linearity error +/- 5% Protective Circuitry Short Circuit Protection Yes Overload Protection Yes Proximity Sensors Connector M8 M12 Agency Listings (R) Output Curves 0 to 10 V XS9F11 XS9E XS9C XS9D Sn = 1 . . . 5 mm Sn = 1 . . . 10 mm Sn = 2 . . . 15 mm Sn = 5 . . . 40 mm 11 10 9 8 7 6 5 4 3 2 1 0 0 2.5 5 11 10 9 8 7 6 5 4 3 2 1 0 6 0 5 10 11 10 9 8 7 6 5 4 3 2 1 0 11 10 9 8 7 6 5 4 3 2 1 0 12 0 7.5 15 0 17 20 40 50 Distance in mm. Output Current Resistance Output Voltage Resistance 12 V 0 ... 10 mA R 560 0 - 10 V Indeterminate 24 V 0 ... 10 mA R 1500 0 - 10 V R = 1000 Note: Ensure a minimum of 5 V between the (+) positive and the sensor output (terminal 3). 4 to 20 mA XS9F11 XS9E XS9C XS9D Sn = 1 . . . 5 mm Sn = 1 . . . 10 mm Sn = 2 . . . 15 mm Sn = 5 . . . 40 mm 22 20 18 16 14 12 10 8 6 4 2 0 22 20 18 16 14 2 10 8 6 4 2 0 22 20 18 16 14 2 10 8 6 4 2 0 22 20 18 16 14 12 10 8 6 4 2 0 0 2.5 5 6 0 5 10 13 0 7.5 15 18.5 0 20 40 50 Distance in mm. Connector Cables (M8 or S suffix; M12 or D suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 Output Current Resistance 12 V 4 ... 20 mA R 82 24 V 4 ... 20 mA R 560 Note: Ensure a minimum of 10 V between the (+) positive and the sensor output (terminal 3). XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 215 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved OSICONCEPTTM Proximity Sensors XS9 Application Specific Inductive Sensor Flat Rectangular Motion Detection, DC and AC/DC XS9 Application Specific Inductive Sensor / Flat Rectangular Motion Detection, DC and AC/DC Features: * Universal AC/DC versions * Linear speed threshold adjustment * Built-in fixed start up delay to overcome start up inertia * Reverse polarity protection on DC models * Ease of mounting (flat body style) Principle and Applications c Inductive proximity sensors for monitoring rotation or rolling speed operate by comparing a speed threshold that has been preset by the operator with an instantaneous measurement of the speed of the moving part to be monitored or protected. c These devices provide a simple and economical solution for monitoring drift, belt breakage, couplings, overloads, etc. Proximity Sensors c They are commonly used for applications such as crushers and grinders, mixers and blenders, pumps, centrifuges and centrifugal separators, conveyor belts, bucket elevators, archimedean screws, etc. Installation and Setup Installing and Positioning the Sensor Output LED Self-teaching LED Power Supply Reference Speed Self-teaching Button c The sensor must be properly positioned at the outset to ensure that all of the target points on the moving part to be monitored can be detected. The XS9 sensor facilitates this task with its ability to operate as a standard inductive sensor (Telemecanique patent pending). c Thanks to this system, positioning is 100% reliable and can be checked at any time without changing the product parameters. Self-teaching Speed Setup > 3 Sec. c The normal or reference speed for the moving part (1) to be monitored can be set by simply pressing the self-teaching button (2). It is then confirmed with the display LED. Slow Flash * In case of uncertainty, the product can be restarted at any time in order to return to the factory setting. > 7 Sec. 1. In order to ensure that the moving part can attain its normal speed (inertia), the product output remains closed for nine seconds. 2. By default, the sensor's underspeed trip speed is equivalent to the preset speed - 30%. Example: if the preset speed is 1000 rotations/min., underspeed tripping will occur when the speed of the moving part falls below 1000 - 1000 x 0.3 = 700 rotations/min. Thresholds of -20%, -11% and -6% can be obtained by pressing the self-teaching button. Nominal Threshold Circuit Voltage Sensing Range Type Range Distance (Pulse/Min.) Size E (13x26x26 mm) M12 pigtail, 0.1 m 10 mm PNP 6-6000 12-24 Vdc Load Current Maximum Maximum Frequency (Pulse/Min.) Start-up Delay Catalog Number 100 mA 48000 9 sec. XS9E11RPB1L01M12 5...100 mA 48000 9 sec. XS9E11RMB3L01U20 200 mA 48000 9 sec. XS9C11RPB1L01M12 5...200 mA AC 5...300 mA DC 48000 9 sec. XS9C11RMB3L01U20 Size E (13x26x26 mm) U20 pigtail, 0.1 m 10 mm 2 wire 6-6000 24-240 Vac/ 24-210 Vdc Size C (15x40x40 mm) M12 pigtail, 0.1 m 15 mm PNP 6-6000 12-24 Vdc Size C (15x40x40 mm) U20 pigtail, 0.1 m 15 mm 2 wire 6-6000 24-240 Vac/ 24-210 Vdc 216 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 OSICONCEPTTM Proximity Sensors XS9 Application Specific Inductive Sensor Flat Rectangular Motion Detection, DC and AC/DC XS9 Application Specific Inductive Sensor / Flat Rectangular Motion Detection, DC and AC/DC Specifications Wiring 3 2 Mechanical 2 Usable Sensing Range Cable 0.5" UNF 1 Blue Brown Black 3 BU - BN + BK Output Temperature Range Enclosure Rating 3 Wire DC XS9*11RPBL01M12 2 Wire AC/DC XS9*11RMBL01U2 XS9E 0 - 8 mm XS9C 0 - 12 mm Storage -40 to +185 F (-40 to +85 C) Operation -13 to +158 F (-25 to +70 C) NEMA Type 1, 4X,12 IEC Type IP67 Vibration 25 g, amplitude +/-2 mm (f=10 to 55 Hz) 2 Shock Resistance 3 LED Indicator 50 g, duration 11 ms Output Yellow Power Green Enclosure material PBT Connector DC: M12 4 pin; AC/DC: U20 3 pin Electrical 2 wire AC/DC 3 wire DC Voltage Range 24 - 240 Vac/24-210 Vdc 12 - 24 Vdc Voltage Limit (including ripple) 20 - 264 Vac/dc 10 - 36 Vdc Voltage Drop 5.5 V 2V (max.) Leakage (Residual) Current-open state 1.5 mA - Current consumption - 10 mA XS9E 100 mA 5...100 mA XS9C 200 mA 5...200 mA; DC 5...300 mA; AC Load Current Maximum XSZBPM12 Max. Frequency (Pulse/Min.) Dimensions 48000 Start up delay (max.) XS9 E/C Protection Circuitry C B E D F Proximity Sensors Connector M12 XS9E 9 seconds + 1/Fr a XS9C 9 seconds + 1/Fr a Overload Protection - Yes Short Circuit Protection - Yes Agency Listings (R) a 1/Fr in the start up delay formula is the actual preset frequency adjusted via potentiometer B E Accessories Description Catalog Number Teach connector mounting bracket XSZBPM12 A Minimum Mounting Clearances (mm) B e 0.8 20 M12; 1/2 UNF F XS9E XS9C e Side by Side Face to Face e 1.6 (40) e 2.4 (60) e 3.1 (80) e 4.7 (120) E 2.4 (62) B A B C D E 0.55 (14) 1.0 (26) 0.5 (13) 0.3 (8.8) 0.8 (20) 0.1 (3.5) C 0.55 (14) 1.6 (40) 0.6 (15) 0.4 (9.8) 1.3 (33) 0.1 (4.5) inches (mm) Connector Cables (M12 or D suffix; U20 or K suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 217 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 4 mm Diameter, DC XS Tubular, Inductive Sensors / 4 mm Diameter, DC Features * Rugged case designed for the industrial environment * Mounting space savings due to short length 1.14 29 LED * Significant replacement time savings by using the patented plastic mounting bracket (no gauging) or connectors * Trouble-free operation ensured by extensive protective circuitry * Works with 24 V secondary transformers * Normally closed (N.C.) output available on versions marked a XS1Lk * UL Listed, CSA Certified and CE Mark Nominal Sensing Circuit Distance Type Voltage Range Output Mode Operating Frequency Mating Connector Style (See p. 518) Catalog Number Nickel plated brass case 1.61 41 Shielded, 2 m (6.6') cable LED 1 mm PNP 5-24 V N.O.a 5000 Hz - XS1L04PA310 1 mm NPN 5-24 V N.O.a 5000 Hz - XS1L04NA310 Shielded, connector - nano style Proximity Sensors 1 mm PNP 5-24 V N.O.a 5000 Hz 1 thru 8 XS1L04PA310S 1 mm NPN 5-24 V N.O.a 5000 Hz 1 thru 8 XS1L04NA310S Stainless steel case Shielded, 2 m (6.6') cable XS1LkS 0.8 mm PNP 5-24 V N.O. 5000 Hz - XS1L04PA311 0.8 mm NPN 5-24 V N.O. 5000 Hz - XS1L04NA311 Shielded, connector - nano style Dual Dimensions inches mm 0.8 mm PNP 5-24 V N.O. 5000 Hz 1 thru 8 XS1L04PA311S 0.8 mm NPN 5-24 V N.O. 5000 Hz 1 thru 8 XS1L04NA311S a To order a normally closed (N.C.) version, change the A to B, example: XS1L04PA310 to XS1L04PB310. Minimum Mounting Clearances (mm/inches) Mounted in a metal support Facing a metal object Face to face Side by side D e XS1 Shielded e e: 2/.08 e e: 12/.47 e: 3/.12 D: 4/.16 218 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 4 mm Diameter, DC XS Tubular, Inductive Sensors / 4 mm Diameter, DC Specifications Wiring Mechanical 4 1 Blue Brown Black 3 Usable sensing range BU - BN + BK Output Enclosure material + BK/4 NO BK/2 NC BU/3 0 to 0.64 mm NEMA Type 3, 4X, 6P, 12, 13 -25 C to +70 C (-13 F to +158 F) Enclosure rating - cable CENELEC Type IP67 Brass case Nickel plated Brass Stainless steel case Stainless steel Sensing face PBT Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2mm, f =10-55Hz Shock resistance (IEC 60068.2.27) 50 G duration 11ms BN/1 PNP 0 to 0.8 mm Stainless Steel Case Standard temperature range (for connector, see p. 518) 3 wire NO or NC wire color/connector pin Shielded Brass case Standard target size (steel) 4 mm x 4 mm Differential (% of Sr) 15% Repeatability (% of Sr) 3% LED indicator type BN/1 + NPN Side mounted LED: Shows output status Cable 27 AWG (0.11mm2), PvR 3 wire Electrical BK/2 NC BK/4 NO BU/3 Voltage range - nominal 5 to 24 Vdc Voltage limit (including ripple) 5 to 30 Vdc Voltage drop (across switch), closed state 2V Maximum load current 100 mA Current consumption (no load) 10 mA On delay (max.) 0.1 ms Off delay (max.) 0.1 ms Power-up delay (max.) 5 ms Protective circuitry Agency Listings (R) E164869 CCN NRKH Proximity Sensors Connector M8 Cable Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 6100-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Reverse polarity protection Yes CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 5 meter cable L1 10 meter cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Mounting bracket, plastic XSZB104 Mounting bracket, diecast zinc 8316 04 Note: Refer to page 351, for target material correction coefficient Km. Connector Cables (M8 or S suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298 219 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 5 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 5 mm Diameter, DC: Economy Short Length Features * Mounting space savings due to short length 1.14 29 .94 24 * Rugged case designed for the industrial environment * Significant replacement time savings by using the patented plastic mounting bracket (no gauging) or connectors LED * Trouble-free operation ensured by extensive protective circuitry * Works with 24 V secondary transformers thread M5x0.5 * Metal mounting nuts included, die cast zinc * Normally closed (N.C.) output available on versions marked a * UL Listed, CSA Certified and CE Mark 41 1.61 .94 24 Nominal Sensing Distance Circuit Type Voltage Range Output Mode Operating Frequency Mating Connector Style (See p.518) Catalog Number Nickel plated brass case LED Shielded, 2 m (6.6') cable 1 mm PNP 5-24 V N.O.a 5000 Hz -- XS1N05PA310 1 mm NPN 5-24 V N.O.a 5000 Hz -- XS1N05NA310 Proximity Sensors Stainless steel case Shielded, 2 m (6.6') cable Dual Dimensions inches mm 0.8 mm PNP 5-24 V N.O. 5000 Hz -- XS1N05PA311 0.8 mm NPN 5-24 V N.O. 5000 Hz -- XS1N05NA311 Shielded, connector - nano style 0.8 mm PNP 5-24 V N.O. 5000 Hz 1 thru 8 XS1N05PA311S 0.8 mm NPN 5-24 V N.O. 5000 Hz 1 thru 8 XS1N05NA311S a To order a normally closed (N.C.) version, change the A to B, example: XS1N05PA310 to XS1N05PB310 Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e XS1 Shielded e: 2/.08 e e: 12/.47 e: 3/.12 D: 5/.20 220 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 5 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 5 mm Diameter, DC; Economy Short Length Specifications Wiring Mechanical Cable 4 1 Blue Brown Black 3 Shielded Brass case Usable sensing range BU - BN + BK Output 3 wire NO or NC wire color/connector pin Stainless steel case Standard temperature range Enclosure rating - cable (for connector, see p. 518) Enclosure material + Max. tightening torque BK/4 NO BK/2 NC Vibration resistance Shock resistance BU/3 BN/1 + NPN NEMA Type 3, 4X, 6P, 12, 13 IEC Type IP67 Brass case Nickel plated Brass Stainless steel case Stainless steel Sensing face PBT Brass 1.6 N*m (1.2 lb-ft) Stainless steel 2.2 N*m (1.75 lb-ft) (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz (IEC 60068.2.27) 50 G duration 11ms Standard target size (steel) 4 mm x 4 mm Differential (% of Sr) 15% Repeatability (% of Sr) 3% LED indicator type BK/2 NC Side mounted LED: Shows output status Cable BK/4 NO 0 to 0.64 mm -25 C to +70 C (-13 F to +158 F) BN/1 PNP 0 to 0.8 mm 27 AWG (0.11 mm2), PvR 3 wire Electrical BU/3 Voltage range - nominal 5 to 24 Vdc Voltage limit (including ripple) 5 to 30 Vdc Voltage drop (across switch), closed state 2V Maximum load current 100 mA Current consumption (no load) 10 mA On delay (max.) 0.1 ms Off delay (max.) 0.1 ms Power-up delay (max.) 5 ms Protective Circuitry Agency Listings (R) Proximity Sensors Connector M8 Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Reverse polarity protection Yes E164869 CCN NRKH CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 5 meter cable L1 10 meter cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Metal, die cast zinc mounting nuts and lock washer XSZE105 Mounting bracket, plastic XSZB105 Mounting bracket, diecast zinc 831605 Stainless steel mounting nuts and lock washer XSZE305 Note: Refer to page 351, for target material correction coefficient Km. Connector Cables (M8 or S suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298 221 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel XS Tubular, Inductive Sensors / 6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel 1.97 50 Features * Faster troubleshooting aided by high visibility 360 indicators * Economy of size offered by extended range model LED * Reduction of relay or software logic using complementary N.O. + N.C. outputs 1.30 33 XS1L06kC * Significant replacement time savings by using the patented plastic mounting bracket (no gauging) or connectors * Trouble-free operation ensured by extensive protective circuitry 1.65 42 LED XS1L06kA * Works with unregulated DC supply powered by 24 V secondary transformer * Metal mounting nuts included LED * Zinc diecast 1.77 45 XS1L06kS * UL Listed, CSA Certified and CE Mark Nominal Sensing Distance 1.30 33 .82 21 LED * Normally closed (N.C.) output available on versions marked a XS1L06kD Circuit Type Voltage Range Output Mode Operating Frequency Indicator Mating LED (see Connector next page) (see p. 518) Catalog Number 12-24 V 12-24 V 12-24 V 12-24 V N.O.a N.O.a N.O.+N.C. N.O.+N.C. 5000 Hz 5000 Hz 5000 Hz 5000 Hz A A A A -- -- -- -- XS1L06PA340 XS1L06NA340 XS1L06PC410 XS1L06NC410 N.O.a N.O.a 5000 Hz 5000 Hz B B 1 thru 8 1 thru 8 XS1L06PA340S XS1L06NA340S N.O. N.O. 5000 Hz 5000 Hz B B 11,12,13,15,16 11,12,14,15,16 XS1L06PA340D XS1L06NA340D A A -- -- XS1L06PA349 XS1L06NA349 B B 1 thru 8 1 thru 8 XS1L06PA349S XS1L06NA349S Stainless steel case LED Shielded, 2 m (6.6') cable 1.65 42 LED PNP NPN PNP NPN .82 21 1.77 45 Shielded, connector - nano style XS1L06k349S .11 3 LED 1.5 mm 1.5 mm PNP NPN 12-24 V 12-24 V Shielded, connector - micro style 1.5 mm 1.5 mm XS1L06k349 PNP NPN 12-24 V 12-24 V 1.18 30 .15 4 Nickel plated brass case Shielded, EXTENDED RANGE 2.5 mm 2.5 mm LED PNP NPN 1.49 38 2.5 mm 2.5 mm XS2L06k PNP NPN .11 3 2.5 mm 2.5 mm XS2L06kS N.O.a N.O.a PNP NPN 2500 Hz 2500 Hz connector - nano style 12-24 V 12-24 V Shielded, EXTENDED RANGE LED 2m (6.6') cable 12-24 V 12-24 V Shielded, EXTENDED RANGE N.O. N.O. 2500 Hz 2500 Hz connector - micro style 12-24 V 12-24 V N.O. N.O. 2500 Hz 2500 Hz B B 11,12,13,15,16 11,12,14,15,16 XS1L06PA349D XS1L06NA349D N.O. N.O. 5000 Hz 5000 Hz A A -- -- XS2L06PA340 XS2L06NA340 N.O. N.O. 5000 Hz 5000 Hz B B 1 thru 8 1 thru 8 XS2L06PA340S XS2L06NA340S 5000 Hz 5000 Hz 5000 Hz 5000 Hz B B B B 11,12,13,15,16 11,12,14,15,16 11,12,13,15,16 11,12,14,15,16 XS2L06PA340D XS2L06NA340D XS2L06PC410D XS2L06NC410D Stainless steel case Non-shielded, 2 m (6.6') cable 1.65 42 2.5 mm 2.5 mm .82 21 Proximity Sensors 1.5 mm 1.5 mm 1.5 mm 1.5 mm XS1L06k349 LED PNP NPN 12-24 V 12-24 V Non-shielded, connector - nano style 2.5 mm 2.5 mm XS2L06kD PNP NPN 12-24 V 12-24 V Non-shielded, connector - micro style DC 2.5 mm 2.5 mm 2.5 mm 2.5 mm Dual Dimensions inches mm PNP NPN PNP NPN 12-24 V 12-24 V 12-24 V 12-24 V N.O. N.O. N.O.+N.C. N.O.+N.C. To order a normally closed (N.C.) version, change A to B, example; XS1L06PA340 to XS1L06PB340. See dimension x below. a Minimum Mounting Clearances (mm/inches) Side to side Facing a metal object Face to face Mounted in a metal support D Mounted in a metal support D x H e XS1 Shielded XS1 Extended range XS2 Non-shielded e e e: 3/.12 e: 5/.20 e:10/.39 e:18/.71 e: 30/1.18 e: 30/1.18 e:4.5/.17 e: 7.5/.30 e: 7.5/.30 D: 6.5/.26; x: 0/0 D: 10/.39; x: 1.6 /.06 D: 19.5/.77, H: 5/.20 222 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel XS Tubular, Inductive Sensors / 6.5 mm Diameter, DC; Economy, Short Length, Smooth Barrel Specifications Wiring Mechanical 4 4 1 Cable 3 3 1 2 Blue Brown Black Usable sensing range BU - BN + BK Output + PNP Standard temperature range Enclosure material BN/1 BK/4 NO BK/2 NC - + Extended Range NEMA Type BU/3 M8 connector, N.O. and N.C. to to pin 4. IEC Type IP67 Case Nickel plated Brass PBT Shock resistance (IEC 60068.2.27) 50 G duration 11 ms Standard target size (steel) 6.5 mm x 6.5 mm Differential (% of Sr) 15% 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 3 wire 27 AWG (0.11mm2), PvR 4 wire (N.O. + N.C.) 28 AWG (0.08mm2), PvR Voltage range - nominal 12 to 24 Vdc Voltage limit (including ripple) 10 to 38 Vdc Voltage drop (across switch), closed state 2V (2.6V extended range) Maximum load current 200 mA Current consumption (no load) 4 wire NO + NC 10 mA On delay (max.) BN/1 BK/4 -25 C to 50 C (13 F to 122 F) 3, 4X, 6P, 12, 13 Electrical - + Off delay (max.) NO WH/2 Standard Range 0.1 ms Extended Range .2 ms Standard Range 0.1 ms Extended Range .2 ms Power-up delay (max.) BU/3 Protective circuitry BN/1 5 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Reverse polarity protection Yes + NC 0 to 2 mm 25 G, amplitude +/- 2 mm, f =10-55Hz Cable BK/4 NO NO -25 C to +70 C (-13 F to +158 F) (IEC 60068.2.6) BK/2 NC NPN Standard Range Sensing face LED indicator type NC 0 to 2 mm Vibration resistance BN/1 PNP 0 to 1.2 mm Extended Range Repeatability (% of Sr) BU/3 NPN Standard Range Non-shielded Enclosure rating - cable (for connector see p. 518) 3 wire NO or NC wire color/ connector pin Shielded Agency Listings BK/4 Proximity Sensors Connector M8 M12 (R) E164869 CCN NRKH CR 44087 Class 3211 03 WH/2 - Options BU/3 Description Suffix Extended temperature range (cable type and standard sensing distance only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Mounting bracket, plastic XSZB165 Mounting bracket, diecast zinc 831606 Note:Refer to p. 351, for target material correction coefficient Km. Connector Cables (M8 or S suffix; M12 or D suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298 223 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Economy Short Length M8x1 1.30 33 1.02 26 thread Features * Faster troubleshooting aided by high visibility 360 indicators * Economy of size offered by extended range model XS1N08k * Significant replacement time savings by using the patented plastic mounting bracket (no gauging) or connectors 1.65 42 1.02 26 LED LED * Works with unregulated DC supply powered by 24 V secondary transformer * Metal mounting lock nuts included * Normally closed (N.C.) output available on versions marked a XS1N08kS .94 24 * Trouble-free operation ensured by extensive protective circuitry 1.77 45 * UL Listed, CSA Certified and CE Mark Nominal Sensing Distance 1.02 26 XS1N08kD 1.30 33 LED Circuit Type Voltage Range Output Mode Operating Frequency Indicator LED (see next page) Mating Catalog Connector Style Number (See p. 518) Nickel plated brass case Shielded, 2 m (6.6') cable LED 1.5 mm PNP 12-24 V N.O.a 5000 Hz A -- XS1N08PA340 1.5 mm NPN 12-24 V N.O.a 5000 Hz A -- XS1N08NA340 1.73 44 1.14 29 XS1N08k349 1.5 mm PNP 12-24 V N.O.a 5000 Hz B 1 thru 8 XS1N08PA340S 1.5 mm NPN 12-24 V N.O.a 5000 Hz B 1 thru 8 XS1N08NA340S Shielded, connector - micro style 1.17 45 .94 24 LED .15 4 XS1N08k349S LED 1.5 mm PNP 12-24 V N.O.a 5000 Hz B 11,12,13,15,16 XS1N08PA340D 1.5 mm NPN 12-24 V N.O.a 5000 Hz B 11,12,14,15,16 XS1N08NA340D Shielded, EXTENDED RANGE 2 m (6.6') cable 2.5 mm PNP 12-24 V N.O.a 2500 Hz A -- XS1N08PA349 2.5 mm NPN 12-24 V N.O.a 2500 Hz A -- XS1N08NA349 XS1N08k349D .15 4 1.14 59 .86 22 Shielded, EXTENDED RANGE connector - nano style LED 1.49 38 .90 23 XS2N08k .15 4 2.5 mm PNP 12-24 V N.O.a 2500 Hz B 1 thru 8 XS1N08PA349S 2.5 mm NPN 12-24 V N.O.a 2500 Hz B 1 thru 8 XS1N08NA349S Shielded, EXTENDED RANGE connector - micro style DC 2.5 mm PNP 12-24 V N.O.a 2500 Hz B 11,12,13,15,16 XS1N08PA349D 2.5 mm NPN 12-24 V N.O.a 2500 Hz B 11,12,14,15,16 XS1N08NA349D Non-shielded, 2 m (6.6') cable 2.5 mm PNP 12-24 V N.O.a 5000 Hz A -- XS2N08PA340 2.5 mm NPN 12-24 V N.O.a 5000 Hz A -- XS2N08NA340 Non-shielded, connector - nano style LED XS2N08kS 1.61 41 .78 20 Proximity Sensors Shielded, connector - nano style 2.5 mm PNP 12-24 V N.O. 5000 Hz B 1 thru 8 XS2N08PA340S 2.5 mm NPN 12-24 V N.O. 5000 Hz B 1 thru 8 XS2N08NA340S Non-shielded, connector - micro style 2.5 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS2N08PA340D 2.5 mm NPN 12-24 V N.O. 5000 Hz B 11,12,14,15,16 XS2N08NA340D a LED To order a normally closed (N.C.) version, change A to B, example; XS1N08PA340 to XS1N08PB340. See dimension x below. XS2N08kD Dual Dimensions inches mm Minimum Mounting Clearances (mm/inches) Side by side Facing a metal object Face to face Mounting in a metal support D Mounted in a metal support D X H e e XS1 Shielded XS1 Extended range XS2 Non-shielded e: 3/.12 e: 5/.20 e: 10/.39 e e: 18/.71 e: 30/1.18 e: 30/1.18 e: 4.5/.18 e: 7.5/.30 e: 7.5/.30 D: 8/.31, H: 0 D: 10/.39, H: 1.6/.06 D: 24/.94, H: 5/.20 x: 0/0 D: 8/.31, x: 1.6/.06 224 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Economy Short Length Specifications Wiring Mechanical 4 4 1 Cable 3 3 1 2 Blue Brown Black BU - BN + BK Output Enclosure material + Standard Range 0 to 1.2 mm Extended Range 0 to 2 mm Standard Range -25 C to +70 C (-13 F to +158 F) Non-shielded Enclosure rating - cable (see page 518) BN/1 0 to 2 mm Extended Range -25 C to 50 C (-13 F to 122 F) NEMA Type 3, 4X, 6P, 12, 13 IEC Type IP67 Case Nickel plated Brass Sensing face PBT Max. tightening torque 5 N*m (3.7 lb-ft) BK/4 NO Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55Hz BK/2 NC Shock resistance (IEC 60068.2.27) 50 G duration 11 ms BU/3 Standard target size (steel) 8 mm x 8 mm Differential (% of Sr) 15% Repeatability (% of Sr) LED indicator type BN/1 + NPN Shielded Standard temperature range 3 wire NO or NC wire color/ connector pin PNP Usable sensing range Cable 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 3 wire 27 AWG (0.11mm2), PvR Electrical BK/2 NC BK/4 NO BU/3 Voltage range - nominal 12 to 24 Vdc Voltage limit (including ripple) 10 to 38 Vdc Voltage drop (across switch), closed state 2 V (2.6 V extended range) Maximum load current 200 mA Current consumption (no load) 10 mA M8 connector, N.O. and N.C. to to pin 4. Standard Range On delay (max.) Off delay (max.) Power-up delay (max.) Protective circuitry Proximity Sensors Connector M8 M12 0.1 ms Extended Range .2 ms Standard Range 0.1 ms Extended Range .2 ms Standard/Extended Range 5 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Extended Range: IEC 61000-4-4 L3 Reverse polarity protection Yes Agency Listings (R) E164869 CCN NRKH CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type and standard sensing distance only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Metal mounting lock nuts XSZE108 Mounting bracket, plastic XSZB108 Mounting bracket, diecast zinc 8316 08 Note:Refer to p. 351, for target material correction coefficient Km. Connector Cables (M8 or S suffix; M12 or D suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . . . . . page 298 225 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, DC; Economy Short Length, Non-corrosive XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Economy Short Length, Non-corrosive 1.30 33 1.02 26 Features thread M8x1 * Faster troubleshooting aided by high visibility 360 indicators * Designed for chemically aggressive environments - cutting oils, grease, washdown, etc. * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors LED * Trouble-free operation ensured by extensive protective circuitry XS4P08k * Works with unregulated DC supply powered by 24 V secondary transformer * Plastic mounting nuts included 1.65 42 1.02 26 * UL Listed, CSA Certified and CE Mark LED XS4P08kD Nominal Sensing Distance Circuit Type Voltage Range Output Mode Operating Frequency Indicator LED (see next page) Mating Connector Style (See p. 518) Catalog Number Plastic Non-shielded, 2 m (6.6') cable 2.5 mm PNP 12-24 V N.O. a 5000 Hz A - XS4P08PA340 2.5 mm NPN 12-24 V N.O. a 5000 Hz A - XS4P08NA340 Proximity Sensors 1.77 45 .94 24 Non-shielded, connector - nano style 2.5 mm PNP 12-24 V N.O. 5000 Hz A 1 thru 8 XS4P08PA340S 2.5 mm NPN 12-24 V N.O. 5000 Hz A 1 thru 8 XS4P08NA340S Non-shielded, connector - micro style LED XS4P08kD 2.5 mm PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS4P08PA340D 2.5 mm NPN 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS4P08NA340D a To order a normally closes (N.C.) version, change A to B, example XS3P08PA340 to XS3P08PB340 Minimum Mounting Clearances (mm/inches) Dual Dimensions inches mm Side by side Facing a metal object Face to face Mounting in a metal support D H e e XS4 Non-shielded e: 10/.39 e e: 30/1.18 e: 7.5/.30 D: 24/.94, H: 5/.20 226 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, DC; Economy Short Length, Non-corrosive XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Economy Short Length, Non-corrosive Specifications Wiring Mechanical 4 1 4 3 1 2 3 Blue Brown Black Shielded Usable sensing range Cable BU - BN + BK Output 3 wire NO or NC wire color/ connector pin Non-shielded Standard temperature range Enclosure rating - cable (for connector, see page 518) NEMA Type 3, 4X, 6P, 12, 13 IEC Type IP67 Case PBT Sensing face Tightening torque (max.) + PNP BK/4 NO BK/2 NC Vibration resistance Shock resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55Hz (IEC 60068.2.27) 50 G duration 11 ms Standard target size (steel) 8 mm x 8 mm Differential (% of Sr) 15% Repeatability (% of Sr) 3% LED indicator type Cable BN/1 + NPN PBT 1 N*m (.74 lb-ft) BU/3 0 to 2 mm -25 C to +80 C (-13 F to +176 F) Enclosure material BN/1 0 to 1.2 mm A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 3 wire 27 AWG (0.11mm2), PvR Electrical Voltage range - nominal 12 to 24 Vdc BK/2 NC Voltage limit (including ripple) 10 to 38 Vdc BK/4 NO Voltage drop (across switch), closed state 2V Maximum load current 200 mA Current consumption (no load) 10 mA On delay (max.) 0.1 ms BU/3 M8 connector, N.O. and N.C. to to pin 4. Off delay (max.) 0.1 ms Power-up delay (max.) 5 ms Protective circuitry Agency Listings (R) E164869 CCN NRKH Proximity Sensors Connector M8 M12 Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L Reverse polarity protection Yes CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk Description Catalog Number Plastic mounting nuts XSZE208 Mounting bracket, plastic XSZB108 Note: Refer to page 351, for target material correction coefficient Km. Connector Cables (M8 or S suffix; M12 or D suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . page 298, 317 227 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, DC; Universal Standard Length XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Universal Standard Length * Faster troubleshooting aided by high visibility 360 indicators 1.97 50 1.57 40 1.97 50 * 2-wire versions simplify wiring * Rugged case designed for very aggressive environments - cutting oils, grease, etc. LED * Pigtail connectors maintain the cutting oil enclosure rating while removing the connector from the aggressive environment XS1M08kk210/410 * Worry-free replacement: standard length, extended temperature and supply voltage range, improved enclosure rating 1.57 40 XS2M08PC410 XS2M08NC410 LED * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors 1.97 50 1.57 40 Features * Trouble-free operation ensured by extensive protective circuitry 2.40 61 1.57 40 * Works with unfiltered rectified power supply * Metal mounting lock nuts included LED * Normally closed (N.C.) output available on versions marked a LED XS1M08k370 1.57 40 M8x1 Output Modea Voltage Max. Range Load Mating Operating Indicator Connector Style Frequency LED (see p. 518) Catalog Number Stainless steel case 2.40 61 y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products Shielded, 2m (6.6') cable 1.5 mm 1.5 mm 1.5 mm 1.5 mm LED 2-wire PNP NPN PNP N.O.a N.O.a N.O.a N.O. 12-48 V 12-48 V 12-48 V 12-48 V 1.5-100 mA 200 mA 200 mA 200 mA 4000 Hz 5000 Hz 5000 Hz 5000 Hz A A A A - - - - XS1M08DA210 XS1M08PA370 XS1M08NA370 XS1M08PA371 12-48 V 12-48 V 12-48 V 12-48 V 12-48 V 1.5-100 mA 1.5-100 mA 200 mA 200 mA 1.5-100 mA 4000 Hz 4000 Hz 5000 Hz 5000 Hz 4000 Hz B A B B A 11,12,15,16 11,12,15,16 11,12,15,16 11,12,15,16 11,12,15,16 XS1M08DA210D XS1M08DA210LD XS1M08PA370D XS1M08NA370D XS1M08DA214LD 12-48 V 12-48 V 12-24 V 12-24 V 200 mA 200 mA 200 mA 200 mA 5000 Hz 5000 Hz 5000 Hz 5000 Hz A A A A - - - - XS4P08PA370 XS4P08NA370 XS4P08PC410 XS4P08NC410 Shielded, connector - micro style DC 1.97 50 1.57 40 XS1M08kk210D/410D 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm LED 2-wire 2-wire PNP NPN 2-wire N.O.a N.O.a N.O.a N.O.a N.O. Plastic case Non-shielded, 2m (6.6') cable 2.5 mm 2.5 mm 2.5 mm 2.5 mm PNP NPN PNP NPN N.O.a N.O.a N.O.+N.C.a N.O.+N.C.a Nickel plated brass case, complementary N.O.+N.C. outputs XSM08DA210LD Shielded, 2m (6.6') cable 1.5 mm 1.5 mm PNP NPN N.O.+N.C. N.O.+N.C. 12-24 V 12-24 V 200 mA 200 mA 5000 Hz 5000 Hz A A - - XS1M08PC410 XS1M08NC410 12-24 V 12-24 V 200 mA 200 mA 5000 Hz 5000 Hz B B 11,12,15,16 11,12,15,16 XS1M08PC410D XS1M08NC410D 12-24 V 12-24 V 200 mA 200 mA 5000 Hz 5000 Hz A A - - XS2M08PC410 XS2M08NC410 200 mA 200 mA 5000 Hz 5000 Hz B B 11,12,15,16 11,12,15,16 XS2M08PC410D XS2M08NC410D Shielded, connector - micro style 1.5 mm 1.5 mm 2.40 61 1.57 40 Proximity Sensors Nominal Circuit Sensing Type Distance XS2M08PC410D XS2M08NC410D thread * UL Listed, CSA Certified and CE Mark LED XS1M08k370D N.O.+N.C. N.O.+N.C. Non-shielded, 2m (6.6') cable 2.5 mm 2.5 mm PNP NPN N.O.+N.C. N.O.+N.C. Non-shielded, connector - micro style 2.5 mm 2.5 mm Dual Dimensions inches mm PNP NPN a PNP NPN N.O.+N.C. N.O.+N.C. 12-24 V 12-24 V See next page under specifications for LED function. Connector is attached to an 0.8 meter (2.6 foot) pigtail cable. With stainless steel mounting nuts and washers. To order a normally closed (N.C.) version, change A to B, example; XS1M08PA370 to XS1M08PB370. Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e XS1Shielded XS2/XS4 Non-shielded e:3/.11 e:10/.39 e e:18/.71 e:30/1.18 e:4.5/.18 e:7.5/.30 D:8/.31, H:0/0 D:24/.94, H:5/.20 228 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, DC; Universal Standard Length XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Universal Standard Length Specifications Wiring Mechanical Shielded Non-shielded 0 to 1.2 mm 0 to 2 mm -25 C to +80 C (-13 F to +176 F) Enclosure rating -cable (for connector, see page 518) NEMA Type IEC Type Stainless Steel case Enclosure material Nickel plated Brass A B 2 or 3 wire 3, 4X, 6P, 12, 13 IP67 stainless steel Case: Nickel plated Brass Sensing face: PBT PBT 9 N*m (6.7 lb-ft) 1 N*m (.74 lb-ft) 9 N*m 25 G, amplitude +/- 2 mm, f = 10-55Hz 50 G duration 11 ms 8 mm x 8 mm 15% 3% 360 ring LED: Shows output status One LED visible from 4 quadrants: Shows output status 27AWG (0.11 mm2), PvR 2 wire 3 wire 2 wire 3 wire 4 wire complementary output 12 to 48 Vdc (12-24 complementary output) 10 to 58 Vdc (10-38 complementary output) 4V 2V 1.5-100 mA 100 mA 200 mA 3 1 Blue Brown Black 2 BU - BN + BK Output 3 wire NO or NC wire color/connector pin Standard temperature range BN/1 Plastic Stainless Steel Plastic Nickel plated Brass (IEC 60068.2.6) (IEC 60068.2.27) + PNP BK/4 NO Max. tightening torque BK/2 NC - Vibration resistance Shock resistance BU/3 Standard target size (steel) Differential (% of Sr) Repeatability (% of Sr) BN/1 + NPN BK/2 NC LED indicator type BK/4 NO - Cable Electrical BU/3 Voltage range - nominal Voltage limit (including ripple) 2 wire, non-polarized BN/3 BU/4 Voltage drop (across switch),closed state +/- Maximum load current -/+ Current consumption 3 wire (no load) Residual (leakage) current, open state, 2 wire 2 wire On delay (max.) 3 wire 4 wire NO + NC BN/1 PNP BK/4 + NO NC Off delay (max.) WH/2 - Power-up delay (max.) BU/3 Proximity Sensors 4 Usable sensing range Cable Connector M12 10 mA 0.6 mA 0.2 ms 0.1 ms 2 wire 3 wire 2 wire 3 wire 0.2 ms 0.1 ms 5 ms 5 ms Short circuit protection Overload Radio frequency immunity (RFI) Electrostatic; transients; impulse Reverse polarity protection CR 44087 Class 3211 03 Yes Yes Protective circuitry BN/1 NPN + NO NC BK/4 WH/2 BU/3 Agency Listings (R) E164869 CCN NRKH IEC 61000-4-3 L3 2 wire IEC 61000-4-2 L3, IEC 61000-4-4 L4; 60947.5.2 L2 3 wire IEC 61000-4-2 L2, IEC 61000-4-4 L3; 60947.5.2 L2 Yes Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) 16.4 ft. (5 meter) cable 32.8 ft. (10 meter) cable TF L1 L2 Accessories XSZB1kk 8316kk Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight Description Catalog Number Plastic mounting nuts Metal mounting nuts and lock washers Mounting bracket, plastic Mounting bracket, diecast zinc Stainless steel mounting nuts Stainless steel lock washers XSZE208 XSZE108 XSZB108 8316 08 XSZE208 XSZE908 Note: Refer to page 351, for target material correction coefficient Km. XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . . page 298, 317 229 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, AC/DC; Universal Standard Length XS Tubular, Inductive Sensors / 8 mm Diameter, AC/DC; Universal Standard Length 50 * Rugged case designed for aggressive environments. * Worry-free replacement: standard length, extended temperature range, AC or DC power supply XS1M08k230 61 2.40 1.57 40 LED * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors * Trouble-free operation ensured by extensive protective circuitry * Normally closed (N.C.) output available on versions markeda .15 4 LED * Plastic mounting nuts for plastic and lock nuts for metal housing included XS1M08k230K * UL Listed, CSA Certified and CE Mark .15 4 1.81 46 1.41 36 Features * Faster troubleshooting aided by high visibility 360 indicator M8x1 1.97 1.57 40 thread Nominal Output Sensing Mode Distance Operating Frequency AC DC 25 Hz 4000 Hz A - XS1M08MA230 24-210 V 25 Hz 4000 Hz B 17,18 XS1M08MA230K 24-210 V 25 Hz 3000 Hz A - XS2M08MA230 DC Indicator Mating Catalog LED (see Connector Style Number next page) (see p. 518) Nickel plated brass case LED Shielded, 2m (6.6') cable 1.5 mm 1.41 36 N.O.a 24-240 V 24-210 V Shielded, connector - micro style AC 2.42 57 XS2M08k230 1.5 mm N.O.a 24-240 V Non-shielded, 2m (6.6') cable LED 2.5 mm N.O.a 24-240 V Non-shielded, connector - micro style AC XS2M08k230K 1.97 50 1.57 40 2.5 mm N.O.a 24-240 V 24-210 V 25 Hz 3000 Hz B 17,18 XS2M08MA230K 24-210 V 25 Hz 3000 Hz A - XS4P08MA230 3000 Hz A 17,18 XS4P08MA230K Plastic case Non-shielded, 2m (6.6') cable 2.5 mm LED N.O.a 24-240 V Non-shielded, connector - micro style AC 2.5 mm a N.O.a 24-240 V 24-210 V 25 Hz To order a normally closed (N.C.) version, change A to B, example; XS1M08MA230 to XS1M08MB230. 61 XS4P08k230 2.40 1.57 40 Proximity Sensors Voltage Range AC LED XS2P08k230K Dual Dimensions inches mm Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e XS1 Shielded XS2/XS4 Non-shielded e:3/.12 e:10/.39 e e:18/.71 e:30/1.18 e:4.5/.18 e:7.5/.30 D:8/.31, H:0/0 D:24/.94, H:5/.20 230 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 8 mm Diameter, AC/DC; Universal Standard Length XS Tubular, Inductive Sensors / 8 mm Diameter, AC/DC; Universal Standard Length Specifications Wiring Mechanical Connector 0.5" 20-UNF 1 2 Cable Blue Brown Black 3 Usable sensing range BU - BN + BK Output L1 +/- Enclosure rating - cable (for connector, see page 518) Enclosure material AC/DC BU/3 L2 -/+ 0 to 1.2 mm Non-shielded 0 to 2 mm NEMA Type 3, 4X, 6P, 12, 13 Standard temperature range wire color/connector pin 2 wire, AC/DC for connector version only BN/2 Shielded Tightening torque (max.) -25 C to +80 C (-13 F to +176 F) IEC Type IP67 Nickel plated brass Case: Nickel plated Brass Sensing face: PBT Plastic PBT Nickel plated brass 9 N*m (79.6 lb-ft) Plastic 1 N*m (.74 lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz Shock resistance (IEC60068.2.27) 50 G duration 11 ms Standard target size (steel) 8 mm x 8 mm Differential (% of Sr) 15% Repeatability (% of Sr) 3% LED indicator type Cable A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 2 wire 27 AWG (0.11 mm2), PvR Voltage range 24 to 240 Vac (50/60 Hz), 24 to 210 Vdc Voltage limit (including ripple) 20 to 264 Vac/Vdc Maximum Voltage drop (across switch), closed state 5.5V Inrush current (inductive @ 20ms) 2A Minimum load current 5 mA Maximum load current 100 mA 20 Vdc 58 IEC 60947-5-2 Utilization category DC-13 Vdc > 58 IEC 60947-5-2 Utilization category DC-12 Residual (leakage) current, open state 24 Vac/Vdc 0.8 mA 120 Vac/Vdc 1.5 mA On delay (max.) .2 ms Off delay (max.) .2 ms Power-up delay (max.) 40 ms Protective circuitry Agency Listings (R) E164869 CCN NRKH Short circuit protection Noa Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3 CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Plastic mounting nuts XSZE208 Metal mounting lock nuts XSZE108 Mounting bracket, plastic XSZB108 Mounting bracket, diecast zinc 831608 Note: Refer to p. 351, for target material correction coefficient Km. a See p. 298 for protective fuses. Connector Cables (U20 or K suffix) XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . . . . . page 298 231 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Electrical Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 12 mm Diameter, DC; Economy Short Length thread 1.30 33 1.02 26 M12x1 Dual Dimensions inches mm * Complementary N.O. + N.C. models * Works with unregulated DC supply powered by 24 V secondary transformer * Rugged metal or plastic cases * Metal lock nuts or plastic mounting nuts included * Patented plastic mounting bracket * Normally closed (N.C.) output available on versions marked a * Connector options 25 * UL Listed, CSA Certified and CE Mark 1.77 45 .98 * Extensive protective circuitry * Extended range models LED XS1N12k Features * 360 LED indicators Nominal Sensing Circuit Distance Type LED Operating Frequency Indicator LED Mating Connector Catalog (see next page) Style (see p. 518) Number Nickel plated brass case XS1N12kD Shielded, 2 m (6.6') cable 1.30 33 1.02 26 Voltage Output Range Mode LED 2 mm PNP 12-24 V N.O. a 5000 Hz A - XS1N12PA340 2 mm NPN 12-24 V N.O. a 5000 Hz A - XS1N12NA340 2 mm PNP 12-24 V N.O. + N.C. 5000 Hz A - XS1N12PC410 2 mm NPN 12-24 V N.O. + N.C. 5000 Hz A - XS1N12NC410 Shielded, connector - micro style 1.77 45 Proximity Sensors .98 25 XS1N12k349 PNP 12-24 V N.O. 5000 Hz B 11,12,13,15,16 XS1N12PA340D 2 mm NPN 12-24 V N.O. 5000 Hz B 11,12,14,15,16 XS1N12NA340D 2 mm PNP 12-24 V N.O. + N.C. 5000 Hz B 11,12,13,15,16 XS1N12PC410D 2 mm NPN 12-24 V N.O. + N.C. 5000 Hz B 11,12,14,15,16 XS1N12NC410D Shielded, EXTENDED RANGE 2 m (6.6') cable 4 mm PNP 12-24 V N.O. a 2500 Hz A - XS1N12PA349 4 mm NPN 12-24 V N.O. a 2500 Hz A - XS1N12NA349 XS1N12k349D Shielded, EXTENDED RANGE 5 .19 LED 2 mm 4 mm PNP 12-24 V N.O.a 2500 Hz B 11,12,13,15,16 XS1N12PA349D 4 mm NPN 12-24 V N.O.a 2500 Hz B 11,12,14,15,16 XS1N12NA349D connector - micro style DC 28 1.10 21 .82 Non-shielded, 2 m (6.6') cable 5 .19 LED 1.57 40 20 .78 LED 33 1.30 12-24 V N.O. 5000 Hz A - XS2N12PA340 NPN 12-24 V N.O. 5000 Hz A - XS2N12NA340 4 mm PNP 12-24 V N.O. + N.C. 5000 Hz A - XS2N12PC410 4 mm NPN 12-24 V N.O. + N.C. 5000 Hz A - XS2N12NC410 4 mm PNP 12-24 V N.O. a 5000 Hz B 11,12,13,15,16 XS2N12PA340D 4 mm NPN 12-24 V N.O. a 5000 Hz B 11,12,14,15,16 XS2N12NA340D 4 mm PNP 12-24 V N.O. + N.C. 5000 Hz B 11,12,13,15,16 XS2N12PC410D 4 mm NPN 12-24 V N.O. + N.C. 5000 Hz B 11,12,14,15,16 XS2N12NC410D Plastic case Non-shielded, 2 m (6.6') cable XS2N12kD 26 PNP 4 mm Non-shielded, connector - micro style DC XS2N12k 1.02 4 mm LED 4 mm PNP 12-24 V N.O. a 5000 Hz A - XS4P12PA340 4 mm NPN 12-24 V N.O. a 5000 Hz A - XS4P12NA340 4 mm PNP 12-24 V N.O. + N.C. 5000 Hz A - XS4P12PC410 4 mm NPN 12-24 V N.O. + N.C. 5000 Hz A - XS4P12NC410 LED XS4P12kD 45 1.77 XS4P12k 27 1.06 Non-shielded, connector - micro style DC 4 mm PNP 12-24 V N.O. a 5000 Hz A 11,12,13,15,16 XS4P12PA340D 4 mm NPN 12-24 V N.O. a 5000 Hz A 11,12,14,15,16 XS4P12NA340D 4 mm PNP 12-24 V N.O. + N.C. 5000 Hz A 11,12,13,15,16 XS4P12PC410D 4 mm NPN 12-24 V N.O. + N.C. 5000 Hz A 11,12,14,15,16 XS4P12NC410D a See X dimension below. To order a normally closed (N.C.) version, change A to B, example; XS1M08MA230 to XS1M08MB230. Minimum Mounting Clearances (mm/inches) Side by side Facing a metal object Face to face Mounting in a metal support D Mounted in a metal support D X H e e XS1 Shielded XS1 Extended range XS2/XS4 Non-shielded e: 4/.16 e: 8/.31 e: 16/.63 e e: 24/.94 e: 48/1.89 e: 48/1.89 e: 6/.24 e: 12/.47 e: 12/.47 D: 12/.47 D: 12/.47 D: 36/1.42, H: 8/.31 x: 0/0 D: 12/.47, x: 2.4/.09 D: 12/.47, x: 2.4/.09 232 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 12 mm Diameter, DC; Economy Short Length Specifications Wiring Mechanical Cable 4 Usable sensing range 3 1 Blue Brown Black 2 BU - BN + BK Output Standard temperature range Shielded 0 to 3.2 mm Ni plated brass -25 C to +70 C (-13 F to +158 F) Plastic -25 C to +80 C (-13 F to +176 F) -25 C to +50 C (-13 F to +122 F) Nickel plated brass + Plastic case BK/4 NO BK/2 NC Enclosure material BU/3 Tightening torque (max.) BN/1 + BK/2 NC NO BK/4 NO - 3, 4X, 6P, 12, 13 IEC Type IP68 Case Nickel plated brass Sensing face PBT Plastic case PBT Nickel plated brass 6 N*m (4.4 lb-ft) 2 N*m (1.5 lb-ft) (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f=10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11 ms Standard target size (steel) 12 mm x 12 mm Differential (% of Sr) 15% 4 wire NO + NC Cable BK/4 IP67 NEMA Type Repeatability (% of Sr) BN/1 + 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 3 wire 22 AWG (0.34 mm2), PvR 4 wire (N.O. + N.C.) 21 AWG (0.22 mm2), PvR Electrical WH/2 BU/3 Voltage range - nominal 12 to 24 Vdc Voltage limit (including ripple) 10 to 38 Vdc Voltage drop (across switch), closed state 2V Maximum load current 200 mA Current consumption (no load) + NO NC 10 mA Standard Range On delay (max.) BN/1 NPN 3, 4X, 6P, 12, 13 IEC Type Vibration resistance LED indicator type NO NC Nickel plated brass NEMA Type Plastic BU/3 PNP 0 to 3.2 mm Non-shielded Enclosure rating - cable (for connector see page 518) BN/1 NPN 0 to 1.6 mm Extended Range Extended range 3 wire NO or NC wire color/connector pin PNP Standard Range Off delay (max.) BK/4 Power-up delay (max.) WH/2 BU/3 Protective circuitry 0.1 ms Extended Range 0.2 ms Standard Range 0.1 ms Extended Range 0.2 ms Standard/Extended Range 5 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 L3 Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Reverse polarity protection Yes Agency Listings (R) E164869 CCN NRKH CR 44087 Class 3211 03 Options 74281 Description 9006PAkk Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Plastic mounting nuts XSZE212 Metal mounting nuts XSZE112 Mounting bracket 90 steel 9006PA12 Mounting bracket, plastic XSZB112 Mounting bracket, diecast zinc 0.5" NPT conduit adapter length: 2" (50.8mm) Connector Cables (M12 or D suffix) 831612 Aluminum 74281 Note: Refer to p. 351 for target material correction coefficient Km. XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 233 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Connector M12 Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, DC; Universal Standard Length XS Tubular, Inductive Sensors / 12 mm Diameter, DC; Universal Standard Length thread 1.97 50 1.65 42 M12x1 Features * Faster troubleshooting aided by high visibility 360 indicators * 2 wire versions simplify wiring * Rugged case designed for aggressive environments * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./ N.C. output circuit. 1.57 40 LED 2.40 61 XS1k210/340/370 * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors * Pigtail connectors, version (0.8m/2.6' cable) provide cutting oil (IP68) rating and connection for aggressive environments LED 1.65 42 XS1k210/ 340/370D * Trouble free operation ensured by extensive protective circuitry * Works with unfiltered rectified power supply 1.97 50 * Metal mounting lock nuts included * Normally closed (N.C.) output available on versions (marked a) * UL Listed, CSA Certified and CE Mark Proximity Sensors LED Nominal Sensing Circuit Distance Type XS1kDA210LD Voltage Output Max. Range Mode Load Operating Indicator Mating Connector Catalog Frequency LED Style (see p. 518) Number Nickel plated brass case 1.97 50 1.65 42 y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products LED .19 5 XS1kDA210LA Shielded, 2 m (6.6') cable 2 mm 2-wire 12-48 V N.O. a 1.5-100 mA 4000 Hz A -- XS1M12DA210 2 mm PNP 12-48 V N.O.a 200 mA 5000 Hz A -- XS1M12PA370 2 mm NPN 12-48 V N.O.a 200 mA 5000 Hz A -- XS1M12NA370 2 mm PNP/NPN 12-24V N.O./N.C. 200 mA 5000 Hz A -- XS1M12KP340 Shielded, connector - micro style DC 2 mm 2-wire 12-48 V N.O. a 1.5-100 mA 4000 Hz B 11,12,15,16 XS1M12DA210D 2 mm PNP 12-48 V N.O.a 200 mA 5000 Hz B 11,12,13,15,16 XS1M12PA370D 2 mm NPN 12-48 V N.O.a 200 mA 5000 Hz B 11,12,14,15,16 XS1M12NA370D 2 mm PNP/NPN 12-24V N.O./N.C. 200 mA 5000 Hz B 11,12,15,16 XS1M12KP340D A 9,10,11,12,15,16 XS1M12DA210LD 1.5-100 mA 4000 Hz A 21,22 XS1M12DA210LA Shielded, connector - micro style DC - 0.8 m (2.6 ft) pigtail 2 mm 2-wire 12-48 V N.O. a 1.5-100 mA 4000 Hz 2 mm .19 5 1.77 45 1.45 37 Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail 1.37 35 LED LED XS2k370D 12-48 V N.O.a 4 mm PNP 12-48 V N.O.a 200 mA 5000 Hz A -- XS2M12PA370 4 mm NPN 12-48 V N.O.a 200 mA 5000 Hz A -- XS2M12NA370 4 mm PNP + NPN 12-24V N.O./N.C. 200 mA 5000 Hz A -- XS2M12KP340 XS2M12PA370D Non-shielded, connector - micro style D 2.20 56 XS2k370 2-wire Non-shielded, 2 m (6.6') cable 4 mm PNP 12-48 V N.O.a 200 mA 5000 Hz B 11,12,13,15,16 4 mm NPN 12-48 V N.O.a 200 mA 5000 Hz B 11,12,14,15,16 XS2M12NA370D 4 mm PNP + NPN 12-24V N.O./N.C. 200 mA 5000 Hz B 11,12,15,16 XS2M12KP340D a To order a normally closed (N.C.) version change the A to B, example: XS1M12PA370 to XS1M12PB370. See next page under specifications for LED function. Dual Dimensions inches mm Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e XS1 Shielded XS2 Non-shielded e: 4/.16 e: 16/.63 e e: 24/.94 e: 48/1.89 e: 6/.24 e: 12/.47 D: 12/.47, H: 0/0 D: 36/1.42, H: 8/.31 234 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, DC; Universal Standard Length XS Tubular, Inductive Sensors / 12 mm Diameter, DC; Universal Standard Length Specifications Wiring Mechanical 1 3 4 2 1 Usable sensing range a 3 2 Blue Brown Black BU - BN + BK Output BN/1 0 to 3.2 mm -25 C to +80 C (-13 F to +176 F) Enclosure rating - cable (for connector, see p. 518) NEMA Type 3, 4X, 6P, 12, 13 Enclosure material Nickel plated brass Tightening torque (max.) Nickel plated brass Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11 ms IEC Type IP68 - cutting oil proof BN/1 + + NPN BK/4 NO BK/2 NC BK/2 NC BK/4 NO - - BU/3 BU/3 BN/1 BN/1 BK/2 NC BK/4 NO - PBT 15 N*m (11 lb-ft) 12 mm x 12 mm 15% Cable - BU/3 Sensing face Differential (% of Sr) + NPN BK/4 NO BK/2 NC Nickel plated Brass Standard target size (steel) LED indicator type + Case Repeatability (% of Sr) 3 wire, selectable PNP/NPN, NO/NC PNP 0 to 1.6 mm Non-shielded Standard temperature range Wire color/connector pin 3 wire NO or NC PNP Shielded BU/3 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 22 AWG (0.34 mm2), PvR 2 or 3 wire Electrical Std KP Models Voltage range - nominal 12 to 48 Vdc 12 to 24 Vdc Voltage limit (including ripple) 4 wire, programmable, NO or NC output BN/1 (NO),BU/3 (NC) + WH/2 PNP BN/1 (NO),BU/3 (NC) + WH/2 BK/4 BU/3 (NO),BU/1 (NC) 2 wire non-polarized BN/3 10 to 38 Vdc 3 wire 2V 2.6 V 2 wire 4V Minimum load current 2 wire 1.5 mA 2 wire 100 mA 3 wire 200 mA NPN BK/4 BU/3 (NO),BU/1 (NC) 10 to 58 Vdc Voltage drop (across switch), closed state +/- Maximum load current 2 wire - 3 wire 10 mA Residual (leakage) current, open state 2 wire 0.5 mA 2 wire 0.2 ms 3 wire 0.1 ms 2 wire 0.2 ms Current consumption (no load) On delay (max.) Off delay (max.) BU/4 -/+ Power-up delay (max.) 3 wire 0.1 ms 2 wire 5 ms 3 wire 5 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) Protective circuitry Electrostatic; transients; impulse (L - indicates level number) Reverse polarity protection Agency Listings (R) E164869 CCN NRKH Proximity Sensors Cable Connector IEC 61000-4-3 Level 3 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3;60947.5.2 L3 3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3;60947.5.2 L3 Yes CR 44087 Class 3211 03 74281 9006PAkk Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk 8316kk Description Catalog Number Plastic mounting nuts XSZE212 Metal mounting lock nuts XSZE112 Connector Cables (M12 or D suffix; U78 or A suffix) Mounting bracket, 90 steel 9006PA12 Mounting bracket, plastic XSZB112 XSZCD101Y Micro Conn., 4 pin, 2 m, straight Mounting bracket, diecast zinc XSZCD111Y Micro Conn., 4 pin, 2 m, 90 0.5" NPT conduit adapter length 2" (50.8mm) XSZCA101Y Micro Conn., 3 pin, 2 m, straight XSZCA111Y Micro Conn., 3 pin, 2 m, 90 a 831612 Aluminum 74281 Refer to page 351 for target material correction coefficient Km. For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 235 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, DC; Universal Standard Length, Non-corrosive XS Tubular, Inductive Sensors / 12 mm Diameter, DC; Universal Standard Length, Non-corrosive thread 1.97 50 42 1.65 M12x1 Features * Faster troubleshooting aided by high visibility 360 indicators * 2 wire versions simplify wiring * High impact stainless steel and plastic cases for aggressive environments - cutting oils, grease, solvents, etc. LED * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./ N.C. output circuit XS1M12k370/371 1.97 50 1.65 42 * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors * Pigtail connector version (0.8 m /2.6 ' cable) provides cutting oil (IP68) rating and connection for aggressive environments. * Trouble free operation ensured by extensive protective circuitry LED * Works with unfiltered rectified power supply * Stainless steel lock nuts for metal or plastic mounting nuts for plastic housings included * Normally closed (N.C.) output available on versions marked a 5 * UL Listed, CSA Certified and CE Mark Nominal Sensing Distance Circuit Type Voltage Range Output Mode Max. Load Mating Operating Indicator Catalog Connector Style Frequency LED Number (see p. 518) 1.77 45 y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products Stainless steel case Shielded, 2m (6.6') cable 50 1.97 1.65 LED XS1P12k370 2-wire 12-48 V N.O. 1.5-100 mA 4000 Hz A -- XS1M12DA211 2 mm PNP 12-48 V N.O. 200 mA 5000 Hz A -- XS1M12PA371 2 mm NPN 12-48 V N.O. 200 mA 5000 Hz A -- XS1M12NA371 2 mm 2-wire 12-48 V N.O. 1.5-100 mA 4000 Hz A 21,22 XS1M12DA211LA Non-shielded, 2m (6.6') cable 4 mm PNP 12-48 V N.O. 200 mA 5000 Hz A -- XS2M12PA371 4 mm NPN 12-48 V N.O. 200 mA 5000 Hz A -- XS2M12NA371 Plastic case Non-shielded, 2m (6.6') cable 4 mm PNP 12-48 V N.O.a 200 mA 5000 Hz A -- XS4P12PA370 4 mm NPN 12-48 V N.O.a 200 mA 5000 Hz A -- XS4P12NA370 4 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 5000 Hz A -- XS4P12KP340 Non-shielded, connector - micro style DC 2.40 61 42 2 mm Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail XS2M12k370/371 42 LED 1,65 Proximity Sensors 1.45 37 .19 XS1M12DA211LA LED 4 mm PNP 12-48 V N.O.a 200 mA 5000 Hz A 11,12,13,15,16 XS4P12PA370D 4 mm NPN 12-48 V N.O.a 200 mA 5000 Hz A 11,12,14,15,16 XS4P12NA370D 4 mm PNP + NPN 12-24 V N.O./N.C. 200 mA 5000 Hz A 11,12,15,16 XS4P12KP340D a XS4P12k370D To order a normally closed (N.C.) version change the A to B, example: XS1M12PA371 to XS1M12PB371. See next page under specifications for LED function. Dual Dimensions inches mm Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e XS1 Shielded XS2/XS4 Non-shielded e: 4/.16 e: 16/.63 e e: 24/.94 e: 48/1.89 e: 6/.24 e: 12/.47 D: 12/.47, H: 0/0 D: 36/1.42, H: 8/.31 236 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, DC; Universal Standard Length, Non-corrosive XS Tubular, INductive Sensors / 12 mm Diameter, DC; Universal Standard Length, Non-corrosive Specifications Wiring 3 4 2 1 3 2 Blue Brown Black BK/2 NC BK/4 NO - 3 wire, selectable PNP/NPN, NO/NC BN/1 BN/1 + + NPN BK/2 NC BK/4 NO BU/3 3, 4X, 6P, 12, 13 (for connector, see p. 518) IEC Type IP68 Tightening torque (max.) BU/3 BK/4 NO BK/2 NC NEMA Type - BU/3 PNP Enclosure rating - cable + NPN BK/4 NO BK/2 NC 0 to 3.2 mm Enclosure material BN/1 + PNP 0 to 1.6 mm Non-shielded Standard temperature range Wire color/connector pin 3 wire NO or NC BN/1 Shielded Usable sensing rangea BU - BN + BK Output BU/3 -25 C to +80 C (-13 F to +176 F) Stainless steel case #303 Stainless steel Sensing face PBT Plastic PBT Stainless steel 30 N*m (22 lb-ft) Plastic 2 N*m (1.5 lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11ms Standard target size (steel) 12 mm x 12 mm Differential (% of Sr) 15% Repeatability (% of Sr) 3% LED indicator type A 360 ring LED: Shows output status Cable 2 or 3 wire 22 AWG (0.34 mm2), PvR Electrical Standard KP-Models Voltage range - nominal 12 to 48 Vdc 12 to 24 Vdc Voltage limit (including ripple) 4 wire, programmable, NO or NC output BN/1 (NO),BU/3 (NC) + WH/2 PNP BK/4 BU/3 (NO),BU/1 (NC) BN/1 (NO),BU/3 (NC) + NPN WH/2 BK/4 BU/3 (NO),BU/1 (NC) 2 wire non-polarized BN/3 BU/4 +/- 10 to 58 Vdc 10 to 38 Vdc Voltage drop (across switch), closed state 3 wire 2V 2.6V 2 wire 4V Minimum load current 2 wire 1.5 mA 2 wire 100 mA 3 wire 200 mA Maximum load current Current consumption (no load) 3 wire 10 mA Residual (leakage) current, open state 2 wire 0.6 mA 2 wire 0.5 ms 3 wire 0.1 ms 2 wire 0.5 ms On delay (max.) Off delay (max.) -/+ Power-up delay (max.) Protective circuitry 3 wire 0.1 ms 2 wire 5 ms 3 wire 5 ms Short circuit protection Yes Overload Yes Proximity Sensors 1 Mechanical Cable Connector Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic; transients; impulse (L - indicates level number) 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3 3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Reverse polarity protection Yes Agency Listings (R) E164869 CCN NRKH CR 44087 Class 3211 03 Options 74281 Description 9006PAkk Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk 8316kk Connector Cables (M12 or D suffix; U78 or A suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 Description Catalog Number Plastic mounting nuts XSZE212 Stainless steel mounting nuts XSZE312 Locknut washers, stainless steel XSZE912 Mounting bracket, 90 steel 9006PA12 Mounting bracket, plastic XSZB112 Mounting bracket, diecast zinc 0.5" NPT conduit adapter length 2" (50.8mm) a 831612 Aluminum 74281 Refer to p. 351 for target material correction coefficient Km. XSZCA101Y Mini Conn., 3 pin, 2 m, straight XSZCA111Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 237 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, AC/DC; Universal Standard Length XS Tubular, INductive Sensors / 12 mm Diameter, AC/DC; Universal Standard Length thread * Faster troubleshooting aided by high visibility 360 indicators * Rugged metal or plastic cases designed for aggressive environments - cutting oils, grease, etc. 1.97 50 1.65 42 M12x1 Features * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68), AC/DC power supply LED 1.57 40 * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors 2.40 61 XS1Mk * Metal locking nuts for metal or plastic mounting nuts for plastic housings included * Normally closed (N.C.) output available on versions marked a * UL Listed, CSA Certified and CE Mark .19 5 LED Nominal AC or Sensing AC/DC Distance XS1MkK Output Voltage Range Modea AC DC Operating Frequency AC SCP DC Mating Indicator Catalog Connector Style LED Number (see p. 518) Nickel plated brass case 2 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 4000 Hz no A -- XS1M12MA230 2 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 4000 Hz yes A -- XS1M12MA250 B 17,18 XS1M12MA230K .19 5 Shielded, connector - micro style AC LED 2 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 4000 Hz no 1.37 35 Non-shielded, 2 m (6.6') cable 4 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 3000 Hz no A -- XS2M12MA230 4 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 3000 Hz yes A -- XS2M12MA250 B 17,18 XS2M12MA230K A -- XS4P12MA230 A 17,18 XS4P12MA230K Non-shielded, connector - micro style AC 2.20 56 XS2Mk 4 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 3000 Hz no Plastic case Non-shielded, 2 m (6.6') cable LED 4 mm AC/DC N.O.a 24-240 V 24-210 V 25 Hz 4000 Hz no Non-shielded, connector - micro style XS2MkK 4 mm 1.97 50 1.65 42 a AC/DC N.O.a 24-240 V 24-210 V 25 Hz 3000 Hz no To order a normally closed (N.C.) version change the A to B, example: XS1M12PA260 to XS1M12PB260. See next page under specifications for LED function. LED 2.40 61 XS3/XS4Pk 1.65 42 Proximity Sensors 1.77 45 1.45 37 Shielded, 2 m (6.6') cable LED XS4PkK Dual Dimensions inches mm Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e XS1 Shielded XS2/XS4 Non-shielded e: 4/.16 e: 16/.63 e e: 24/.94 e: 48/1.89 e: 6/.24 e: 12/.47 D: 12/.47, H: 0/0 D: 36/1.42, H: 8/.31 238 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular, Inductive Sensors 12 mm Diameter, AC/DC; Universal Standard Length XS Tubular, Inductive Sensors / 12 mm Diameter, AC/DC; Universal Standard Length Specifications Wiring Mechanical Connector 1 2 Cable Blue Brown Black 3 BU - BN + BK Output wire color/connector pin 2 wire, AC/DC for connector version only BN/2 L1 +/- Usable sensing rangea L2 -/+ 0 to 1.6 mm Non-shielded 0 to 3.2 mm Standard temperature range Enclosure rating - cable (for connector, see p. 518) Enclosure material AC/DC BU/3 Shielded Tightening torque (max.) -25 C to +80 C (-13 F to +176 F) NEMA Type 3, 4X, 6P, 12, 13 IEC Type IP68 Nickel plated brass case Nickel plated Brass Sensing face PBT Plastic case PBT Nickel plated brass 15 N*m (11 lb-ft) Plastic 2 N*m (1.5 lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11 ms Standard target size (steel) 12 mm x 12 mm Differential (% of Sr) 15% Repeatability (% of Sr) LED indicator type Cable 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 2 wire 22 AWG (0.34 mm2), PvR Voltage range 24 to 240 Vac (50/60 Hz), 24 to 210 Vdc Voltage limit (including ripple) 20 to 264 Vac/Vdc Maximum Voltage drop (across switch), closed state 5.5V Inrush current (inductive @ 20ms) 2A Minimum load current 5 mA Maximum load current 200 mA 20 Vdc 58 IEC 60947-5-2 Utilization category DC-13 Vdc > 58 IEC 60947-5-2 Utilization category DC-12 Residual (leakage) current, open state 0.6 mA On delay (max.) 0.2 ms Off delay (max.) Power-up delay (max.) 0.2 ms Without SCP 40 ms With SCP 70 ms Protective circuitry Short circuit protection Optionalq Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic; transients; impulse (L - level number) Agency Listings (R) IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3 E164869 CCN NRKH CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length 74281 9006PAkk Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories Description Catalog Number Plastic mounting nuts XSZE212 Metal mounting nuts and lock washers XSZE112 Mounting bracket, 90 steel 9006PA12 Mounting bracket, plastic XSZB112 Mounting bracket, diecast zinc XSZB1kk 8316kk 0.5" NPT conduit adapter length 2" (50.8 mm) a q 831612 Aluminum 74281 Refer to p. 351 for target material correction coefficient Km. For devices without SCP, see p. 298 for protective fuses. Connector Cables (U20 or K suffix) XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 239 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Electrical Proximity Sensors XS Tubular, Inductive Sensors 18 mm Diameter, DC; Economy Short Length XS Tubular, Inductive Sensors / 18 mm Diameter, DC; Economy Short Length M18x1 1.31 33.5 1.02 26 thread 1.77 45 1.02 26 * Complementary N.O. + N.C. models * Works with unregulated DC supply powered by 24 V secondary transformer * Rugged metal or plastic cases * Metal locknuts or plastic mounting nuts included * Patented plastic mounting bracket * Normally closed (N.C.) output available on versions markeda * Connector options LED XS1k340/410D 1.31 33.5 1.02 26 * Extensive protective circuitry * Extended range models LED XS1k340/410 Features * 360 LED indicators Nominal Sensing Distance Circuit Type Voltage Range * UL Listed, CSA Certified and CE Mark Output Mode Operating Frequency Indicator LED Mating Connector Style (see p. 518) Catalog Number Nickel plated brass case LED 1.77 45 1.02 26 Shielded, 2 m (6.6') cable XS1k349 LED .31 8 XS1k349D 10-38 V N.O.a 2000 Hz A - XS1N18PA340 NPN 10-38 V N.O.a 2000 Hz A - XS1N18NA340 5 mm PNP 10-38 V N.O. + N.C. 2000 Hz A - XS1N18PC410 5 mm NPN 10-38 V N.O. + N.C. 2000 Hz A - XS1N18NC410 5 mm PNP 10-38 V N.O. 2000 Hz B 11,12,13,15,16 XS1N18PA340D 5 mm NPN 10-38 V N.O. 2000 Hz B 11,12,14,15,16 XS1N18NA340D 5 mm PNP 10-38 V N.O. + N.C. 2000 Hz B 11,12,13,15,16 XS1N18PC410D 5 mm NPN 10-38 V N.O. + N.C. 2000 Hz B 11,12,14,15,16 XS1N18NC410D Shielded, EXTENDED RANGE, 2 m (6.6') cable .31 8 .88 22.5 18 PNP 5 mm Shielded, connector - micro style DC LED 10 mm PNP 10-38 V N.O. a 1000 Hz A - XS1N18PA349 10 mm NPN 10-38 V N.O.a 1000 Hz A - XS1N18NA349 Shielded, EXTENDED RANGE, connector - micro style 1.45 37 18 .70 XS2k340/410 LED XS2kD 1.31 33.5 26 1.02 10 mm PNP 10-38 V N.O.a 1000 Hz B 11,12,13,15,16 XS1N18PA349D 10 mm NPN 10-38 V N.O.a 1000 Hz B 11,12,14,15,16 XS1N18NA349D Non-shielded, 2 m (6.6') cable 8 mm PNP 10-38 V N.O. 2000 Hz A - XS2N18PA340 8 mm NPN 10-38 V N.O. 2000 Hz A - XS2N18NA340 8 mm PNP 10-38 V N.O. + N.C. 2000 Hz A - XS2N18PC410 8 mm NPN 10-38 V N.O. + N.C. 2000 Hz A - XS2N18NC410 Non-shielded, connector - micro style LED XS4k340/410 8 mm PNP 10-38 V N.O. 2000 Hz B 11,12,13,15,16 XS2N18PA340D 8 mm NPN 10-38 V N.O. 2000 Hz B 11,12,14,15,16 XS2N18NA340D 8 mm PNP 10-38 V N.O. + N.C. 2000 Hz B 11,12,13,15,16 XS2N18PC410D 8 mm NPN 10-38 V N.O. + N.C. 2000 Hz B 11,12,14,15,16 XS2N18NC410D Plastic case 1.77 45 1.14 29 Proximity Sensors .70 5 mm LED XS4kD Non-shielded, 2 m (6.6') cable 8 mm PNP 10-38 V N.O.a 2000 Hz A - XS4P18PA340 8 mm NPN 10-38 V N.O.a 2000 Hz A - XS4P18NA340 8 mm PNP 10-38 V N.O. + N.C. 2000 Hz A - XS4P18PC410 8 mm NPN 10-38 V N.O. + N.C. 2000 Hz A - XS4P18NC410 Non-shielded, connector - micro style Dual Dimensions inches mm 8 mm PNP 10-38 V N.O.a 2000 Hz A 11,12,13,15,16 XS4P18PA340D 8 mm NPN 10-38 V N.O.a 2000 Hz A 11,12,14,15,16 XS4P18NA340D 8 mm PNP 10-38 V N.O. + N.C. 2000 Hz A 11,12,13,15,16 XS4P18PC410D 8 mm NPN 10-38 V N.O. + N.C. 2000 Hz A 11,12,14,15,16 XS4P18NC410D a To order a normally closed (N.C.) version change the A to B, example: XS1N18PA340 to XS1N18PB340. See next page under specifications for LED function. See dimension X below. Minimum Mounting Clearances (mm/inches) Side by side Facing a metal object Face to face Mounting in a metal support D Mounted in a metal support D X H e e XS1 Shielded XS1 Extended range XS2/XS4 Non-shielded e: 10/.39 e: 20/.79 e: 16/.63 e e: 60/2.36 e: 96/3.78 e: 96/3.78 e: 15/.59 e: 24/.94 e: 24/.94 D: 18/.71, H: 0/0 D: 18/.70 D: 18/.71, x: 3.6/.14 D: 54/2.13, H: 16/.63 240 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, DC; Economy Short Length XS Tubular Inductive Sensors / 18 mm Diameter, DC; Economy Short Length Specifications Wiring 3 1 Blue Brown Black 2 BU - BN + BK Output Usable sensing rangea Standard temperature range Wire color/connector pin 3 wire NO or NC Extended Range Nickel plated brass -25 C to +70 C (-13 F to +158 F) Plastic -25 C to +80 C (-13 F to +176 F) Enclosure rating - cable for connector, see p. 518 Plastic BK/2 NC Nickel plated brass Enclosure material BU/3 Plastic BN/1 Tightening torque (max.) + BK/2 NC NEMA Type IP67 NEMA Type 3, 4X, 6P, 12, 13 IEC Type IP68 Case Nickel plated brass Sensing face PBT Case PBT Sensing face PBT 15 N*m (11 lb-ft) Plastic 5 N*m (3.7 lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f =10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11 ms Standard target size (steel) BU/3 Shielded Standard range 0.7" x 0.7" (18 mm x 18 mm) Extended range 1.18" x 1.18" (30 mm x 30 mm) Unshielded 0.94" x 0.94" (24 mm x 24 mm) Differential (% of Sr) 4 wire NO + NC 15% Repeatability (% of Sr) BN/1 PNP NO NC BK/4 + WH/2 - BN/1 NPN + NO NC LED indicator type Cable BU/3 BK/4 WH/2 - 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 3 or 4 wire 22 AWG (0.34 mm2), PvR Electrical Voltage range - nominal 12 to 24 Vdc Voltage limit (including ripple) 10 to 38 Vdc Voltage drop (across switch), closed state 2V Maximum load current 200 mA Current consumption (no load) 10 mA On delay (max.) 0.15 ms Off delay (max.) 0.35 ms Power-up delay (max.) 5 ms BU/3 Protective circuitry Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic; transients; impulse IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Extended range: IEC 61000-4-4 L3 Reverse polarity protection Yes Agency Listings (R) 74281 3, 4X, 6P, 12, 13 IEC Type Nickel plated brass BK/4 NO - 0 to 8 mm 0 to 6.4 mm -25 C to +50 C (-13 F to +122 F) BK/4 NO - 0 to 4 mm Non-shielded Nickel plated brass + NPN Standard Range Extended range BN/1 PNP Shielded E 164869 CCN NRKH CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type and standard sensing distance only) 9006PAkk Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk Description Catalog Number Plastic mounting nuts XSZE218 Metal mounting nuts and lock washer XSZE118 Mounting bracket 90 steel 9006PA18 Mounting bracket, plastic, long length Connector Cables (M12 or D suffix) 0.5" NPT conduit adapter length 2" (50.8 mm) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 a XSZB118 Aluminum 7428 Stainless 74282 Refer to p. 351 for target material correction coefficient Km. For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298. 316 241 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors 4 Mechanical Cable Connector Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, DC; Universal Standard Length XS Tubular Inductive Sensors / 18 mm Diameter, DC; Universal Standard Length * Faster troubleshooting aided by high visibility 360 indicators 2.36 60 2.02 51.5 1.97 50 1.65 42 Features * 2 wire versions simplify wiring * Rugged case designed for aggressive industrial environments LED * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./ N.C. output circuit LED XS1M18DA210 XS1M18k 2.75 70 2.02 51.5 2.36 60 1.65 42 * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors LED XS1M18DA210D * Works with unfiltered rectified power supply * Pigtail connector version (0.8 m/2.6' cable) provides cutting oil (IP68) ratings and connection for aggressive environments. Screw terminals models for wiring special cables. LED .31 8 XS1M18k370D * Metal mounting lock nuts included * Normally closed (N.C.) output available on versions marked a * UL Listed, CSA Certified and CE Mark 2.95 75 2.16 55 * Trouble free operation ensured by extensive protective circuitry 2.04 52 1.71 43.5 LED Nominal Circuit Voltage Output Sensing Type Range Mode Distance Shielded, 2m (6.6') cable Max. Load Operating Indicator Mating Connector Catalog Frequency LED Style (see p. 518) Number 1.5-100 mA 200 mA 200 mA 200 mA 3000 Hz 2000 Hz 2000 Hz 2000 Hz y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products XS1M18k370A LED .31 8 1.97 50 1.65 42 XS2M18k370 5 mm 5 mm 5 mm 5 mm 2-wire PNP NPN PNP + NPN 12-48 V 12-48 V 12-48 V 12-24 V N.O.a N.O.a N.O.a N.O./N.C. A A A A -- -- -- -- XS1M18DA210 XS1M18PA370 XS1M18NA370 XS1M18KP340 A 11,12,15,16 XS1M18DA210LD B B B B 11,12,15,16 11,12,13,15,16 11,12,14,15,16 11,12,15,16 XS1M18DA210D XS1M18PA370D XS1M18NA370D XS1M18KP340D A 21,22 XS1M18DA210LA Shielded connector - micro style DC - 0.8 m (2.6 ft) pigtail 5 mm 2-wire 12-48 V N.O.a 1.5-100 mA 3000 Hz Shielded, connector - micro style DC 2.44 62 1.17 43.5 LED XS1M18DA210LD 5 mm XS2M18k370D 4.17 106 5 mm 5 mm 5 mm 5 mm 2-wire PNP NPN PNP + NPN 12-48 V 12-48 V 12-48 V 12-24 V N.O.a N.O.a N.O.a N.O./N.C. 1.5-100 mA 200 mA 200 mA 200 mA 3000 Hz 2000 Hz 2000 Hz 2000 Hz Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail LED 2.03 51.5 2-wire 12-48 V N.O.a 1.5-100 mA 3000 Hz Shielded, connector - mini style 3 PIN 5 mm 5 mm PNP NPN 12-48 V 12-48 V N.O.a N.O.a 200 mA 200 mA 2000 Hz 2000 Hz B B 21,22 21,22 XS1M18PA370A XS1M18NA370A N.O.a N.O.a N.O.a 1.5-100mA 200 mA 200 mA 3000 Hz 2000 Hz 2000 Hz B B B -- -- -- XS1M18DA210B XS1M18PA370B XS1M18NA370B N.O.a N.O.a N.O./N.C. 200 mA 200 mA 200 mA 2000 Hz 2000 Hz 2000 Hz A A A -- -- -- XS2M18PA370 XS2M18NA370 XS2M18KP340 200 mA 200 mA 200 mA 2000 Hz 2000 Hz 2000 Hz B B B 11,12,13,15,16 11,12,14,15,16 11,12,15,16 XS2M18PA370D XS2M18NA370D XS2M18KP340D Shielded, screw terminal connection 1.65 42 LED XS2M18kB 1.97 50 Proximity Sensors Nickel plated brass case LED XS1M18DA210LA Dual Dimensions inches mm thread M18x1 5 mm 5 mm 5 mm 2 wire PNP NPN 12-48 V 12-48 V 12-48 V Non-shielded, 2m (6.6') cable 8 mm 8 mm 8 mm PNP 12-48 V NPN 12-48 V PNP + NPN 12-24 V Non-shielded, connector - micro style 8 mm 8 mm 8 mm a PNP 12-48 V NPN 12-48 V PNP + NPN 12-24 V N.O.a N.O.a N.O./N.C. To order a normally closed (N.C.) version change the A to B, example: XS1M18PA370 to XS1M18PB370. See next page under specifications for LED function. Minimum Mounting Clearances (mm/inches) Facing a metal object Face to face Side by side Mounting in a metal support D H e XS1 Shielded XS2 Non-shielded e e e: 10/.39 e: 16/.63 e: 60/2.36 e: 96/3.78 e: 15/.59 e: 24/.94 D: 18/.71, H: 0/0 D: 54/2.13, H: 8/.31 242 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, DC; Universal Standard Length XS Tubular Inductive Sensors / 18 mm Diameter, DC; Universal Standard Length Specifications Wiring 1 2 Blue Brown Black Usable sensing rangea BU - BN + BK Output + NPN BK/4 NO BK/2 NC BK/2 NC BK/4 NO - - BU/3 BU/3 Cable Connector 1 0 to 6.4 mm -25 C to +80 C (-13 F to +176 F) Enclosure rating - cable (for connector, see p. 518) NEMA Type 3, 4X, 6P, 12, 13 IEC Type IP68 - cutting oil proof; IP67 for B screw terminal Enclosure material Nickel plated brass Tightening torque (max.) Nickel plated brass Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11ms BN/1 + PNP 0 to 4 mm Non-shielded Standard temperature range Wire color/connector pin 3 wire NO or NC BN/1 Shielded 3 BU - BN + BK Output 4 wire, programmable, NO or NC output BN/1 (NO),BU/3 (NC) + WH/2 PNP BK/4 BU/3 (NO),BU/1 (NC) BN/1 (NO),BU/3 (NC) + NPN WH/2 BK/4 BU/3 (NO),BU/1 (NC) 2 wire non-polarized BN/3 BU/4 +/- -/+ Cable 0.7" x 0.7" (18 mm x 18 mm) 0.94" x 0.94" (24 mm x 24 mm) 15% 3% A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 2 wire 20 AWG (0.5 mm2), PvR 3 wire 22 AWG (0.34 mm2), PvR Electrical Std. KP-Models Voltage range - nominal 12 - 48 Vdc 12 - 24 Vdc Voltage limit (including ripple) 10 - 58 Vdc 10 - 38 Vdc Voltage drop (across switch), closed state 3 wire 2V 2.6 V 2 wire 4V Minimum load current 2 wire 1.5 mA 2 wire 100 mA Maximum load current 3 wire 200 mA Current consumption (no load) 3 wire 10 mA Residual (leakage) current, open state 2 wire 0.5 mA On delay (max.) Off delay (max.) 2 wire 0.2 ms 3 wire 0.15 ms 2 wire 0.2 ms 3 wire 0.35 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Power-up delay (max.) Protective circuitry 5 ms Electrostatic; transients; impulse 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3 (L - indicates level number) 3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Reverse polarity protection Yes Agency Listings (R) 74281 35 N*m 26 (26 lb-ft) Non-shielded Repeatability (% of Sr) LED indicator type Sensing face: PBT Shielded Differential (% of Sr) Blue Brown Black 2 Standard target size (steel) Case: Nickel plated brass Proximity Sensors 3 Mechanical Cable Connector 4 E 164869 CCN NRKH CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) 9006PAkk Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk Connector Cables (M12 or D suffix; U78 or A suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight Description Catalog Number Plastic mounting nuts XSZE218 Metal mounting nuts and lock washers XSZE118 Mounting bracket, 90 steel 9006PA 18 Mounting bracket, plastic 0.5" NPT conduit adapter length 2" (50.8 mm) XSZCD111Y Micro Conn., 4 pin, 2 m, 90 XSZCA101Y Micro Conn., 3 pin, 2 m, straight a XSZB118 Aluminum 7428 Stainless 74282 Refer to p. 351 for target material correction coefficient Km. XSZCA111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . page 298, 316 243 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, DC; Universal Standard Length, Non-corrosive XS Tubular Inductive Sensors / 18 mm Diameter, DC; Universal Standard Length, Non-corrosive * Faster troubleshooting aided by high visibility 360 indicators 1.97 50 1.65 42 Features * 2 wire versions simplify wiring * High impact stainless steel and plastic cases for aggressive environments - cutting oils, grease, solvents, etc. LED 2.36 60 2.02 51.5 XS1M18DA211 LED * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68) * Pigtail connector version (0.8 m /2.6' cable) provides cutting oil (IP68) ratings and connection for aggressive environments. * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors XS1M18k371 * Trouble free operation ensured by extensive protective circuitry 1.65 42 * Works with unfiltered rectified power supply 1.97 50 * Stainless steel locknuts for metal or plastic mounting nuts for plastic housings included * Normally closed (N.C.) output available on versions marked a * UL Listed, CSA Certified and CE Mark .31 8 XS1M18DA211LA Nominal Sensing Distance Circuit Type Voltage Range Output Mode Max. Load Mating Operating Indicator Connector Style Frequency LED (see p. 518) Catalog Number y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products Shielded, 2 m (6.6') cable 2.04 52 1.71 43.5 Stainless steel case LED 5 mm 5 mm 5 mm 5 mm 12-48 V 12-48 V 12-48 V N.O.a N.O. N.O. 1.5-100 mA 3000 Hz 200 mA 2000 Hz 200 mA 2000 Hz A A A -- -- -- XS1M18DA211 XS1M18PA371 XS1M18NA371 2-wire 12-48 V N.O.a 1.5-100 mA 3000 Hz A 21,22 XS1M18DA211LA N.O. N.O. 200 mA 200 mA 2000 Hz 2000 Hz A A -- -- XS2M18PA371 XS2M18NA371 N.O.a N.O.a N.O./N.C. 200 mA 200 mA 200 mA 2000 Hz 2000 Hz 2000 Hz A A A -- -- -- XS4P18PA370 XS4P18NA370 XS4P18KP340 200 mA 200 mA 200 mA 2000 Hz 2000 Hz 2000 Hz A A A 11,12,13,15,16 11,12,14,15,16 11,12,15,16 XS4P18PA370D XS4P18NA370D XS4P18KP340D 200 mA 200 mA 2000 Hz 2000 Hz A A -- -- XS4P18PA370B XS4P18NA370B Non-shielded, 2 m (6.6') cable 8 mm 8 mm PNP NPN 12-48 V 12-48 V Plastic case 2.36 60 XS4P18k370 2.75 70 Non-shielded, 2 m (6.6') cable 2.02 51.5 LED 2-wire PNP NPN Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail XS2M18k371 2.02 51.5 Proximity Sensors LED 8 mm 8 mm 8 mm Non-shielded, connector - micro style 8 mm 8 mm 8 mm LED XS4P18k370D thread M18x1 PNP 12-48 V NPN 12-48 V PNP + NPN 12-24 V N.O.a N.O.a N.O./N.C. Non-shielded, screw terminal connector 8 mm 8 mm Dual Dimensions inches mm PNP 12-48 V NPN 12-48 V PNP + NPN 12-24 V a PNP NPN 12-48 V 12-48 V N.O. N.O. To order a normally closed (N.C.) version change the A to B, example: XS1M12PA371 to XS1M12PB371. See next page under specifications for LED function. Minimum Mounting Clearances (mm/inches) Facing a metal object Face to face Side by side Mounting in a metal support D H e XS1 Shielded XS2/XS4 Non-shielded e e e: 10/.39 e: 16/.63 e: 60/2.36 e: 96/3.78 e: 15/.59 e: 24/.94 D: 18/.71, H: 0/0 D: 54/2.13, H: 8/.31 244 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, DC; Universal Standard Length, Non-corrosive XS Tubular Inductive Sensors / 18 mm Diameter, DC; Universal Standard Length, Non-corrosive Specifications Wiring Mechanical 3 1 Blue Brown Black 2 Usable sensing rangea BU - BN + BK Output Wire color/connector pin 3 wire NO or NC Enclosure material BN/1 + PNP + NPN BK/4 NO BK/2 NC BK/2 NC BK/4 NO - 1 BU/3 Cable 3 Blue Brown Black 2 0 to 6.4 mm NEMA Type 3, 4X, 6P, 12, 13 BU - BN + BK Output -25 C to +80 C (-13 F to +176 F) IEC Type IP68 Stainless steel Case #303 Stainless steel Sensing face PBT Plastic PBT Stainless steel 50 N*m 37 (lb-ft) Plastic 5 N*m 3.7 (lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11 ms Shielded 0.7" x 0.7" (18 mm x 18 mm) Tightening torque (max.) - BU/3 Connector 0 to 4 mm Non-shielded Standard temperature range Enclosure rating - cable (for connector, see p. 518) BN/1 Shielded Standard target size (steel) Non-shielded 0.94" x 0.94" (24 mm x 24 mm) Differential (% of Sr) 15% Repeatability (% of Sr) 4 wire, programmable, NO or NC output BN/1 (NO),BU/3 (NC) + WH/2 PNP BN/1 (NO),BU/3 (NC) + WH/2 BK/4 BU/3 (NO),BU/1 (NC) 2 wire non-polarized BN/3 Cable 3% A 360 ring LED: Shows output status 2 wire 20 AWG (0.5 mm2), PvR 3 wire 22 AWG (0.34 mm2), PvR NPN BK/4 BU/3 (NO),BU/1 (NC) LED indicator type +/- Standard Voltage range 12 to 48 Vdc 12 to 24 Vdc Voltage limit (including ripple) 10 to 58 Vdc 10 to 38 Vdc 2 wire 4V - 3 wire 2V - 4 wire - 2.6 Voltage drop (across switch), closed state Nickel plated brass & Stainless Plastic BU/4 Minimum load current -/+ KPModels Electrical Maximum load current Residual (leakage) current, open state 3 wire 2V 2 wire 1.5 mA 2 wire 100 mA 3 wire 200 mA 2 wire 0.6 mA On delay (max.) 0.15 ms Off delay (max.) 0.35 ms Power-up delay (max.) 5 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) Protective circuitry Electrostatic; transients; impulse (L - indicates level number) Reverse polarity protection Agency Listings (R) E 164869 CCN NRKH IEC 61000-4-3 Level 3 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3 3 wire: IEC 6000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3 Yes CR 44087 Class 3211 03 7428k Options Description Suffix Extended temperature range (cable type only) 9006PAkk Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk Connector Cables (M12 or D suffix; U78 or A suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 XSZCA101Y Micro Conn., 3 pin, 2 m, straight Description Catalog Number Plastic mounting nuts XSZE218 Stainless steel mounting nuts XSZE318 Locknut washers, stainless steel XSZE918 Mounting bracket, 90 steel 9006PA18 Mounting bracket, plastic 0.5" NPT conduit adapter length 2" (50.8mm) XSZCA111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . page 298, 316 a XSZB118 Aluminum 7428 Stainless 74282 Refer to p. 351 for target material correction coefficient Km. 245 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Cable Connector 4 Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, AC/DC; Universal Standard Length XS Tubular Inductive Sensors / 18 mm Diameter, AC/DC; Universal Standard Length * 360 LED indicators 2.75 70 2.02 51.5 2.36 60 2.02 51.5 Features * Extended temperature range * Extended supply voltage range LED * IP68 AC/DC power supply LED XS1M18 .31 8 XS1M18kK * Patented plastic mounting bracket * Connector options 2.16 55 * Extensive protective circuitry 2.04 52 1.71 43.5 2.95 75 * Metal locknuts for metal or plastic mounting nuts for plastic housings included * Normally closed (N.C.) output available on versions marked a * UL Listed, CSA Certified and CE Mark LED Nominal AC or Output Voltage Range Sensing AC/DC Mode Distance AC DC LED XS1M18kA XS2M18k SCP Mating Indicator Catalog Connector LED Number Style (see p. 518) 25 Hz 25 Hz 3000 Hz 3000 Hz no yes A C -- -- XS1M18MA230 XS1M18MA250 25 Hz 25 Hz 3000 Hz 3000 Hz no yes B B 17,18 17,18 XS1M18MA230K XS1M18MA250K 25 Hz 25 Hz 3000 Hz 3000 Hz no yes B C 23,24 23,24 XS1M18MA230A XS1M18MA250A 25 Hz 3000 Hz no B -- XS1M18MA230B 25 Hz 25 Hz 2000 Hz 2000 Hz no yes A C -- -- XS2M18MA230 XS2M18MA250 25 Hz 25 Hz 2000 Hz 2000 Hz no yes B B 23,24 23,24 XS2M18MA230K XS2M18MA250K 25 Hz 25 Hz 2000 Hz 2000 Hz no yes B C 18 18 XS2M18MA230A XS2M18MA250A 25 Hz 2000 Hz no A -- XS4P18MA230 25 Hz 2000 Hz no A 17,18 XS4P18MA230K 25 Hz 2000 Hz no A 23,24 XS4P18MA230A 25 Hz 2000 Hz no B -- XS4P18MA230B .31 8 .31 8 Nickel brass case Shielded, 2 m (6.6') cable 5 mm 5 mm AC/DC AC/DC N.O.a N.O.a 24-240 V 24-210 V 24-240 V 24-210 V 2.63 67 1.85 47 2.44 62 1.71 43.5 Shielded, connector - micro style AC LED 5 mm 5 mm AC/DC AC/DC N.O.a N.O.a 24-240 V 24-210 V 24-240 V 24-210 V Shielded, connector - mini style 5 mm 5 mm LED XS2M18kK AC/DC AC/DC N.O.a N.O.a 24-240 V 24-210 V 24-240 V 24-210 V Shielded, screw terminal connection XS2M18kA 5 mm AC/DC N.O.a 24-240 V 24-210 V Non-shielded, 2 m (6.6') cable AC/DC AC/DC N.O.a N.O.a 24-240 V 24-210 V 24-240 V 24-210 V 2.75 70 Non-shielded, connector - micro style AC 2.02 51.5 2.36 60 2.02 51.5 8 mm 8 mm 8 mm 8 mm AC/DC AC/DC N.O.a N.O.a 24-240 V 24-210 V 24-240 V 24-210 V Non-shielded, connector - mini style 8 mm 8 mm LED LED XS4P18k230 XS4P18k230K AC/DC AC/DC N.O.a N.O.a 24-240 V 24-210 V 24-240 V 24-210 V Plastic case Non-shielded, 2 m (6.6') cable 8 mm AC/DC N.O.a 24-240 V 24-210 V Non-shielded, connector - micro style 8 mm AC/DC N.O.a 24-240 V 24-210 V Non-shielded, connector - mini style 2.89 73.5 2.04 52 Proximity Sensors Operating Frequencies AC DC 8 mm AC/DC N.O.a 24-240 V 24-210 V Shielded, screw terminal connection 8 mm LED a XS4P18k230A Dual Dimensions inches mm AC/DC N.O.a 24-240 V 24-210 V To order a normally closed (N.C.) version change the A to B, example: XS1M12PA260 to XS1M12PB260. See next page under specifications for LED function. thread M18x1 Minimum Mounting Clearances (mm/inches) Facing a metal object Face to face Side by side Mounting in a metal support D H e XS1 Shielded XS2/XS4 Non-shielded e e e: 10/.39 e: 16/.63 e: 60/2.36 e: 96/3.78 e: 15/.59 e: 24/.94 D: 18/.71, H: 0/0 D: 54/2.13, H: 8/.31 246 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 OSICONCEPTTM Proximity Sensors XS Tubular Inductive Sensors 18 mm Diameter, AC/DC; Universal Standard Length XS Tubular Inductive Sensors / 18 mm Diameter, AC/DC; Universal Standard Length Specifications Wiring 2 3 Mechanical Cable 3 2 Usable sensing rangea Blue Brown Black BU - BN + BK Output Wire color/connector pin 2 wire, AC/DC or AC BN/2 BU/3 Enclosure rating - cable (for connector, see p. 518) +/- L1 L2 Tightening torque (max.) -/+ 0 to 4 mm 0 to 6.4 mm -25 C to +80 C (-13 F to +176 F) NEMA Type IEC Type 4X, 6P, 12, 13 IP68 Nickel plated brass PBT PBT 35 N*m 26 (lb-ft) 5 N*m 3.7 (lb-ft) 25 G, amplitude +/- 2 mm, f = 10-55 Hz Standard temperature range Enclosure material AC/DC Shielded Non-shielded Vibration resistance Shock resistance Standard target size (steel) Nickel plated brass Case Sensing face Plastic Nickel plated brass Plastic (IEC 60068.2.6) (IEC 60068.2.27) Shielded Non-shielded 50 G duration 11 ms 0.7" x 0.7" (18 mm x 18 mm) 0.94" x 0.94" (24 mm x 24 mm) 15% 3% 360 ring LED: Shows output status One LED visible from 4 quadrants: Shows output status 2 LED indicators: Red shows output status Green shows normal operation (SCP only) 20 AWG (0.5 mm2), PvR 22 AWG (0.34 mm2), PvR Differential (% of Sr) Repeatability (% of Sr) LED indicator type A B C 2 wire 3 wire Cable Electrical Voltage range Voltage limit (including ripple) Voltage drop (across switch), closed state (max) Inrush current Minimum load current 24 to 240 Vac, 24-210 Vdc 20 to 264 Vac/dc 5.5 V Maximum load current Residual (leakage) current, open state On delay (max) Off delay (max) Power-up delay (max.) Protective circuitry Agency Listings without SCP with SCP without SCP with SCP without SCP with SCP without SCP with SCP Short circuit protection Radio frequency immunity (RFI) Electrostatic; transients; impulse E 164869 CR 44087 CCN NRKH Class 3211 03 2A 5 mA 200 mA 20 Vdc 58 IEC 60947-5-2 Utilization category DC-13 Vdc > 58 IEC 60947-5-2 Utilization category DC-12 0.6 mA 1.5 mA 0.2 ms 2 ms 0.2 ms 4 ms 40 ms 70 ms Optionalq IEC 61000-4-3 Level 3 IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3 (R) Options 7428k Description Suffix Extended temperature range (cable type only) Extended cable length 9006PAkk XSZB1kk TF L1 L2 Accessories Description Catalog Number Plastic mounting nuts Metal mounting nuts and lock washers Mounting bracket, 90 steel Mounting bracket, plastic XSZE218 XSZE118 9006PA18 XSZB118 7428 74282 0.5" NPT conduit adapter length 2" (50.8 mm) Connector Cables (U20 or K suffix; U78 or A suffix) Down to -40 C (-40 F) 5 meter cable 10 meter cable a q Aluminum Stainless Refer to p. 351 for target material correction coefficient Km. For devices without SCP, see p. 298 for protective fuses. XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 XSZCA101Y Micro Conn., 3 pin, 2 m, straight XSZCA111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 247 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Connector Micro Mini 1 1 Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, DC; Economy Short Length XS Tubular Inductive Sensors / 30 mm Diameter, DC; Economy Short Length thread Features * 360 LED indicators 1.59 40.5 1.26 32 M30x1.5 * Works with unregulated DC supply powered by 24 V secondary transformer * Extended range models * Complementary N.O. + N.C. models LED * Rugged metal or plastic cases 1.97 50 1.18 30 XS1N30k * Connector options XS1N30kD Nominal Sensing Distance Circuit Type * UL Listed, CSA Certified and CE Mark Voltage Range Operating Indicator Mating Connector Frequency LED Style (see p. 518) Catalog Number N.O.a N.O.a N.O. + N.C. N.O. + N.C. 1000 Hz 1000 Hz 1000 Hz 1000 Hz A A A A -- -- -- -- XS1N30PA340 XS1N30NA340 XS1N30PC410 XS1N30NC410 N.O.a N.O.a N.O. + N.C. N.O. + N.C. 1000 Hz 1000 Hz 1000 Hz 1000 Hz B B B B 11,12,13,15,16 11,12,14,15,16 11,12,13,15,16 11,12,14,15,16 XS1N30PA340D XS1N30NA340D XS1N30PC410D XS1N30NC410D 500 Hz 500 Hz A A -- -- XS1N30PA349 XS1N30NA349 500 Hz 500 Hz B B 11,12,13,15,16 11,12,14,15,16 XS1N30PA349D XS1N30NA349D N.O. N.O. N.O. + N.C. N.O. + N.C. 1000 Hz 1000 Hz 1000 Hz 1000 Hz A A A A -- -- -- -- XS2N30PA340 XS2N30NA340 XS2N30PC410 XS2N30NC410 N.O. N.O. N.O. + N.C. N.O. + N.C. 1000 Hz 1000 Hz 1000 Hz 1000 Hz B B B B 11,12,13,15,16 11,12,14,15,16 11,12,13,15,16 11,12,14,15,16 XS2N30PA340D XS2N30NA340D XS2N30PC410D XS2N30NC410D N.O. N.O. N.O. + N.C. N.O. + N.C. 1000 Hz 1000 Hz 1000 Hz 1000 Hz A A A A -- -- -- -- XS4P30PA340 XS4P30NA340 XS4P30PC410 XS4P30NC410 1.59 40.5 Shielded, 2 m (6.6') cable LED 1.18 30 PNP NPN PNP NPN 12-24 V 12-24 V 12-24 V 12-24 V 1.97 50 Shielded, connector - micro style LED 10 mm 10 mm 10 mm 10 mm PNP NPN PNP NPN 12-24 V 12-24 V 12-24 V 12-24 V Shielded, EXTENDED RANGE, 2 m (6.6') cable XS1N30k349D .51 13 20 mm 20 mm PNP NPN 12-24 V 12-24 V N.O.a N.O.a 20 mm 20 mm 27.5 .74 19 Shielded, EXTENDED RANGE, connector - micro style PNP NPN 12-24 V 12-24 V N.O.a N.O.a Non-shielded, 2 m (6.6') cable .51 13 LED XS2N340k 15 mm 15 mm 15 mm 15 mm PNP NPN PNP NPN 12-24 V 12-24 V 12-24 V 12-24 V 1.45 37 .74 19 Non-shielded, connector - micro style LED 15 mm 15 mm 15 mm 15 mm PNP NPN PNP NPN 12-24 V 12-24 V 12-24 V 12-24 V Plastic case XS2N30kD 1.97 50 1.59 40.5 LED 1.33 34 Non-shielded, 2 m (6.6') cable 1.30 33 Proximity Sensors Output Mode Nickel plated brass case 10 mm 10 mm 10 mm 10 mm XS1N30k349 * Normally closed (N.C.) output available on versions mode marked a * Extensive protective circuitry LED 1.26 32 * Patented plastic mounting bracket * Metal locknuts for metal or plastic mounting nuts for plastic housing included XS4P30kD thread Dual Dimensions inches mm PNP NPN PNP NPN 12-24 V 12-24 V 12-24 V 12-24 V Non-shielded, connector - micro style LED XS4P30 15 mm 15 mm 15 mm 15 mm 15 mm PNP 12-24 V N.O. 1000 Hz A 11,12,13,15,16 15 mm NPN 12-24 V N.O. 1000 Hz A 11,12,14,15,16 15 mm PNP 12-24 V N.O. + N.C. 1000 Hz A 11,12,13,15,16 15 mm NPN 12-24 V N.O. + N.C. 1000 Hz A 11,12,14,15,16 a To order a normally closed (N.C.) version change the A to B, example: XS1N12PA340 to XS1N12PB340. See next page under specifications for LED function. See dimension X below. XS4P30PA340D XS4P30NA340D XS4P30PC410D XS4P30NC410D M30x1.5 Minimum Mounting Clearances (mm/inches) Face to face Side by side Facing a metal object Mounting in a metal support D Mounting in a metal support D x H e XS1 Shielded XS1 Extended range XS2/XS4 Non-shielded e e e: 20/.79 e: 40/1.57 e: 60/2.36 e: 120/4.72 e: 240/9.45 e: 180/7.09 e: 30/1.18 e: 60/2.36 e: 45/1.77 D: 30/1.18, H: 0/0 x: 0/0 x: 6/.24 D: 90/3.54, H: 30/1.18 248 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, DC; Economy Short Length XS Tubular Inductive Sensors / 30 mm Diameter, DC; Economy Short Length Specifications Wiring Mechanical 3 1 Blue Brown Black 2 BU - BN + BK Output Usable sensing rangea Standard temperature range Wire color/connector pin 3 wire NO or NC + Enclosure rating - cable (for connector, see p. 518) BK/2 NC Plastic Enclosure material Plastic BU/3 Tightening torque (max.) BN/1 + Vibration resistance Shock resistance Standard target size (steel) BU/3 A + Cable B 3 or 4 wire 0 to 8 mm 0 to 16 mm 0 to 12 mm -25 C to +70 C (-13 F to +158 F) -25 C to +80 C (-13 F to +176 F) -25 C to 50 C (-13 F to +122 F) 3, 4X, 6P, 12, 13 IP67 3, 4X, 6P, 12, 13 IP68 Nickel plated brass PBT PBT PBT 40 N*m 29.5 (lb-ft) 20 N*m 15 (lb-ft) 25 G, amplitude +/- 2 mm, f = 10-55 Hz 50 G duration 11 ms 1.18" x 1.18" (30 mm x 30 mm) 1.88" x 1.88" (48 mm x 48 mm) 1.41" x 1.41" (36 mm x 36 mm) 15% 3% 360 ring LED: Shows output status One LED visible from 4 quadrants: Shows output status 22 AWG (0.34 mm2), PvR Electrical WH/2 BU/3 BN/1 + NO NC Standard Range Extended range Unshielded LED indicator type BN/1 NO NC Shielded Differential (% of Sr) Repeatability (% of Sr) 4 wire NO + NC BK/4 NEMA Type IEC Type NEMA Type IEC Type Case Sensing face Case Sensing face Nickel plated brass Plastic (IEC 60068.2.6) (IEC 60068.2.27) BK/2 NC BK/4 NO NPN Nickel plated brass Nickel plated brass - PNP Non-shielded Nickel plated brass Plastic BK/4 NO NPN Standard Range Extended Range Extended range BN/1 PNP Shielded Proximity Sensors Cable Connector 4 Voltage range Voltage limit (including ripple) Voltage drop (across switch), closed state Maximum load current Current consumption (no load) On delay (max.) Off delay (max.) BU/3 Standard Range Extended Range Non-shielded BK/4 WH/2 Shielded Shielded Standard Range Extended Range Non-shielded Power up delay Short circuit protection Overload Radio frequency immunity (RFI) Protective circuitry Reverse polarity protection E 164869 CCN NRKH Agency Listings 7427 Electrostatic; transients; impulse (L - indicates level number) (R) 12 to 24 Vdc 10 to 38 Vdc 2V 200 mA 10 mA 0.3 ms 0.6 ms 0.3 ms 0.7 ms 1.4 ms 0.7 ms 5 ms Yes Yes IEC 61000-4-3 Level 3 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L2; 60947.5.2 L3 3 wire: IEC 61000-4-2 L3; IEC 61000-4-4L3; 60947.5.2 L3 Extended range: IEC 61000-4-4 L3 Yes CR 44087 Class 3211 03 Options Description 9006PAkk XSZB1kk Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . page 298, 316 Suffix Extended temperature range (cable type and standard sensing distance only) Down to -40 C (-40 F) TF Extended cable length 16.4 ft. (5 meter) cable 32.8 ft. (10 meter) cable L1 L2 Accessories Description Catalog Number Plastic mounting nuts Metal mounting nuts and lock nuts Mounting bracket 90 steel Mounting bracket, plastic, long length 0.5" NPT conduit adapter length 2" (50.8mm) XSZE230 XSZE130 9006PA30 XSZB130 7427 a Aluminum Refer to p. 351 for target material correction coefficient Km. 249 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, DC; Universal Standard Length XS Tubular Inductive Sensors / 30 mm Diameter, DC; Universal Standard Length 2.36 60 2.02 51.5 1.97 50 1.65 42 Features * 2 wire versions simplify wiring * Rugged case designed for aggressive industrial environments LED LED XS1M30DA210 2.75 70 2.36 60 2.02 51.5 XS1M30k370 1.57 40 * Faster troubleshooting aided by high visibility 360 indicators * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./ N.C. output circuit * Pigtail connector version (0.8 m /2.6' cable) provides cutting oil (IP68) ratings and connection for aggressive environments. LED * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors XS1M30k370D * Trouble free operation ensured by extensive protective circuitry LED .51 13 XS1M30DA210D * Works with unfiltered rectified power supply * Metal mounting lock nuts included 2.95 74 1.51 38.5 1.85 47 2.12 54 * Normally closed (N.C.) output available on versions marked a XS2M30k370 Voltage Output Range Mode Max. Load Mating Operating Indicator Connector Style Frequency LED (see p. 518) Catalog Number 2000 Hz 1000 Hz 1000 Hz 1000 Hz .51 13 10 mm 10 mm 10 mm 10 mm 2-wire PNP NPN PNP + NPN 12-48 V 12-48 V 12-48 V 12-24 V N.O.a N.O.a N.O.a N.O./N.C. 1.5-100 mA 200 mA 200 mA 200 mA A A A A -- -- -- -- XS1M30DA210 XS1M30PA370 XS1M30NA370 XS1M30KP340 1.5-100 mA 2000 Hz A 11,12,15,16 XS1M30DA210LD 1.5-100 mA 200 mA 200 mA 200 mA B B B B 11,12,15,16 11,12,13,15,16 11,12,14,15,16 11,12,15,16 XS1M30DA210D XS1M30PA370D XS1M30NA370D XS1M30KP340D A 21,22 XS1M30DA210LA 1000 Hz 1000 Hz B B 21,22 21,22 XS1M30PA370A XS1M30NA370A N.O.a N.O.a N.O.a 1.5-100 mA 2000 Hz 200 mA 1000 Hz 200 mA 1000 Hz B B B -- -- -- XS1M30DA210B XS1M30PA370B XS1M30NA370B N.O.a N.O.a N.O./N.C. 200 mA 200 mA 200 mA 1000 Hz 1000 Hz 1000 Hz A A A -- -- -- XS2M30PA370 XS2M30NA370 XS2M30KP340 200 mA 200 mA 200 mA 1000 Hz 1000 Hz 1000 Hz B B B 11,12,13,15,16 11,12,14,15,16 11,12,15,16 XS2M30PA370D XS2M30NA370D XS2M30KP340D Shielded, connector - micro style DC - 0.8 m (2.6 ft) pigtail 57 2.24 Nickel plated brass case Shielded, 2 m (6.6') cable M30x1.5 1.51 Nominal Circuit Sensing Type Distance y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products XS1M30k370A thread 38.5 10 mm 2-wire 12-48 V N.O.a Shielded, connector - micro style DC LED 1.97 50 1.65 42 XS2M30k370D LED 10 mm 10 mm 10 mm 10 mm 2-wire PNP NPN PNP + NPN 12-48 V 12-48 V 12-48 V 12-24 V N.O.a N.O.a N.O.a N.O./N.C. 2000 Hz 1000 Hz 1000 Hz 1000 Hz Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail 10 mm 2-wire 12-48 V N.O.a 1.5-100 mA 2000 Hz Shielded, connector - mini style 10 mm 10 mm PNP NPN 12-48 V 12-48 V N.O. N.O. 200 mA 200 mA Shielded, connector - screw terminal connection XS1M30DA210LD 1.65 42 15 mm 15 mm 15 mm 2 wire PNP NPN 12-48 V 12-48 V 12-48 V PNP NPN PNP + NPN 12-48 V 12-48 V 12-24 V Non-shielded, connector - micro style LED XS1M30DA210LA Dual Dimensions inches mm 10 mm 10 mm 10 mm Non-shielded, 2 m (6.6') cable 1.97 50 Proximity Sensors LED LED * UL Listed, CSA Certified and CE Mark thread M30x1.5 15 mm 15 mm 15 mm a PNP NPN PNP + NPN 12-48 V 12-48 V 12-24 V N.O.a N.O.a N.O./N.C. To order a normally closed (N.C.) version change the A to B, example: XS1M12PA370 to XS1M12PB370. See next page under specifications for LED function. Minimum Mounting Clearances (mm/inches) Face to face Side by side Mounting in a metal support D Facing a metal object H XS1 Shielded XS2 Non-shielded e e e e: 20/.79 e: 60/2.36 e: 120/4.72 e: 180/7.09 e: 30/1.18 e: 45/1.77 D: 30/1.18, H: 0/0 D: 90/3.54, H: 30/1.18 250 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, DC; Universal Standard Length XS Tubular Inductive Sensors / 30 mm Diameter, DC; Universal Standard Length Specifications Wiring Mechanical 3 1 Blue Brown Black 2 Usable sensing rangea BU - BN + BK Output BN/1 + NPN BK/2 NC BK/4 NO - BU/3 Cable Connector 1 Blue Brown Black 2 BU - BN + BK Output 4 wire, programmable, NO or NC output BN/1 (NO),BU/3 (NC) + WH/2 PNP BK/4 BU/3 (NO),BU/1 (NC) BN/1 (NO),BU/3 (NC) + NPN WH/2 BK/4 BU/3 (NO),BU/1 (NC) 2 wire non-polarized BN/3 BU/4 +/- -/+ 0 to 8 mm 0 to 12 mm -25 C to +80 C (-13 F to +176 F) Enclosure rating - cable (for connector, see p. 518) NEMA Type Enclosure material Nickel plated brass Tightening torque (max.) Nickel plated brass 50 N*m 37 (lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz IEC Type BN/1 + BK/4 NO BK/2 NC BU/3 3 Non-shielded Standard temperature range Wire color/connector pin 3 wire NO or NC PNP Shielded Shock resistance Standard target size (steel) 3, 4X, 6P, 12, 13 IP68 - cutting oil proof, IP67 for B screw terminals Case: Nickel plated Brass Sensing face: PBT (IEC 60068.2.27) 50 G duration 11 ms Shielded 1.18" x 1.18" (30 mm x 30 mm) Non-shielded 1.41" x 1.41" (36 mm x 36 mm) Differential (% of Sr) 15% Repeatability (% of Sr) 3% LED indicator type Cable A 360 ring LED: Shows output status B One LED visible from 4 quadrants: Shows output status 2 wire 20 AWG (0.5 mm2), PvR 22 AWG (0.34 mm2), PvR 3 wire Electrical Std. KP-Models Voltage range - nominal 12-48 Vdc 12-24 Vdc Voltage limit (including ripple) 10-58 Vdc 10-38 Vdc Voltage drop (across switch), closed state 3 wire 2V 2.6 V 2 wire 4V Minimum load current 2 wire 1.5 mA 2 wire 100 mA Maximum load current 3 wire 200 mA Current consumption (no load) 3 wire 10 mA Residual (leakage) current, open state 2 wire 0.5 mA 2 wire 0.2 ms 3 wire 0.3 ms 2 wire 0.3 ms On delay (max.) Off delay (max.) 3 wire Proximity Sensors Cable Connector 4 0.7 ms Power-up delay (max.) 5 ms Protective circuitry Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic; transients; impulse (L - indicates level number) 2 wire IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3 3 wire IEC 61000-4-2 L3; IEC 61000-4-4 L2; 60947.5.2 L3 Reverse polarity protection Yes Agency Listings (R) E 164869 CCN NRKH CR 44087 Class 3211 03 7427 Options Description Suffix Extended temperature range (cable type only) 9006PAkk Extended cable length Down to -40+ C (-40+ F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories XSZB1kk Connector Cables (M12 or D suffix; U78 or A suffix) Description Catalog Number Metal mounting lock nuts XSZE130 Mounting bracket, 90 steel and lock washers 9006PA30 Mounting bracket, plastic 0.5" NPT conduit adapter length 2" (50.8mm) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 a XSZB130 Aluminum 7427 Refer to p. 351 for target material correction coefficient Km. XSZCA101Y Micro Conn., 3 pin, 2 m, straight XSZCA111Y Micro Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 251 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, DC; Universal Standard Length, Non-Corrosive XS Tubular Inductive Sensors / 30 mm Diameter, DC; Universal Standard Length, Non-corrosive M30x1.5 1.97 50 1.65 42 thread Features * Faster troubleshooting aided by high visibility 360 indicators * 2 wire versions simplify wiring * High impact stainless steel and plastic cases for aggressive environments - cutting oils, grease, solvents, etc. LED 2.36 60 2.02 51.5 XS1M30kDA2 * Significant replacement time savings using patented plastic mounting bracket (no gauging) or connectors LED XS1M30k371 1.65 42 * Pigtail connector version (0.8 m /2.6' cable) provides cutting oil (IP68) ratings and connection for aggressive environments. 1.97 50 * Trouble free operation ensured by extensive protective circuitry * Works with unfiltered rectified power supply * Stainless steel or plastic mounting nuts included .51 13 LED XS1M30DA211LA * Worry free replacement: standard length, extended temperature and supply voltage range, improved enclosure ratings (IP68), 3 wire complementary PNP + NPN with selectable N.O./ N.C. output circuit * Normally closed (N.C.) output available on versions markeda * UL Listed, CSA Certified and CE Mark Circuit Type Voltage Output Range Mode Max Load Mating Operating Indicator Catalog Connector Style Frequency LED Number (see p. 518) y it il b a il a v A t c u d ro P d e it Lim on DC Two Wire Products 1.85 47 1.51 38.5 Proximity Sensors Nominal Sensing Distance Stainless steel case Shielded, 2 m (6.6') cable LED 10 mm 2-wire 12-48 V N.O.a 1.5-100 mA 2000 Hz A -- XS1M30DA211 10 mm PNP 12-48 V N.O. 200 mA 1000 Hz A -- XS1M30PA371 10 mm NPN 12-48 V N.O. 200 mA 1000 Hz A -- XS1M30NA371 2000 Hz A 11,12,15,16 XS1M30DA211LD Shielded, connector - micro style - 0.8 m (2.6 ft) pigtail 2.36 60 2.02 51.5 XS2M30k371 10 mm 2-wire 12-48 V N.O.a 1.5-100 mA Shielded, connector - mini style - 0.8 m (2.6 ft) pigtail 10mm 2-wire 12-48 V N.O.a 1.5-100 mA 2000 Hz A 21,22 XS1M30DA211LA Non-shielded, 2 m (6.6') cable LED XS4P30k370 15 mm PNP 12-48 V N.O. 200 mA 1000 Hz A -- XS2M30PA371 15 mm NPN 12-48 V N.O. 200 mA 1000 Hz A -- XS2M30NA371 Non-shielded, 2 m (6.6') cable 2.75 70 2.02 51.5 Plastic case LED 15 mm PNP 12-48 V N.O.a 200 mA 1000 Hz A -- XS4P30PA370 15 mm NPN 12-48 V N.O.a 200 mA 1000 Hz A -- XS4P30NA370 15 mm PNP/NPN 12-24 V N.O./N.C. 200 mA 1000 Hz A -- XS4P30KP340 Non-shielded, connector - micro style DC XS4P30k370D Dual Dimensions inches mm 15 mm PNP 12-48 V N.O.a 200 mA 1000 Hz A 11,12,13,15,16 XS4P30PA370D 15 mm NPN 12-48 V N.O.a 200 mA 1000 Hz A 11,12,14,15,16 XS4P30NA370D 15 mm PNP/NPN 12-24 V N.O/.N.C. 200 mA 1000 Hz A 11,12,15,16 XS4P30KP340D a To order a normally closed (N.C.) version change the A to B, example: XS1M12PA371 to XS1M12PB371. See next page under specifications for LED function. Minimum Mounting Clearances (mm/inches) Face to face Side by side Mounting in a metal support D Facing a metal object H XS1 Shielded XS2/XS4 Non-shielded e e e e: 20/.79 e: 60/2.36 e: 120/4.72 e: 180/7.09 e: 30/1.18 e: 45/1.77 D: 30/1.18, H: 0/0 D: 90/3.54, H: 30/1.18 252 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, DC; Universal Standard Length, Non-Corrosive XS Tubular Inductive Sensors / 30 mm Diameter, DC; Universal Standard Length, Non-corrosive Specifications Wiring Mechanical 3 1 Blue Brown Black 2 Usable sensing rangea BU - BN + BK Output Enclosure rating cable (for connector, see p. 517) Enclosure material BN/1 + PNP + NPN BK/4 NO BK/2 NC BK/2 NC BK/4 NO BU/3 1 - Cable 3 Blue Brown Black 2 BU - BN + BK Output 4 wire, programmable, NO or NC output BN/1 (NO),BU/3 (NC) + WH/2 PNP BN/1 (NO),BU/3 (NC) + NPN BK/4 BU/3 (NO),BU/1 (NC) 0 to 12 mm WH/2 BK/4 BU/3 (NO),BU/1 (NC) -25 C to +80 C (-13 F to +176 F) NEMA Type 3, 4X, 6P, 12, 13 IEC Type Stainless steel IP68 Case #303 Stainless steel Sensing face PBT Plastic Tightening torque (max.) BU/3 Connector 0 to 8 mm Non-shielded Standard temperature range Wire color/connector pin 3 wire NO or NC BN/1 Shielded PBT Stainless steel 100 N*m 74 (lb-ft) Plastic 20 N*m 15 (lb-ft) Vibration resistance (IEC 60068.2.6) 25 G, amplitude +/- 2 mm, f = 10-55 Hz Shock resistance (IEC 60068.2.27) 50 G duration 11 ms Shielded 1.18" x 1.18" (30 mm x 30 mm) Standard target size (steel) Non-shielded 1.41" x 1.41" (36 mm x 364 mm) Differential (% of Sr) 15% Repeatability (% of Sr) LED indicator type Cable 3% A 360 ring LED: Shows output status 2 wire 20 AWG (0.5 mm2), PvR 3 wire 22 AWG (0.34 mm2), PvR Electrical Standard KP-Models Voltage range - nominal 12 to 48 Vdc 12-24 Vdc 10 to 58 Vdc 10-38 Vdc Voltage limit (including ripple) 2 wire Voltage drop (across switch), closed state 2 wire non-polarized BN/3 +/- Minimum load current Maximum load current BU/4 -/+ 4V 3 wire 2V 4 wire - 2.6 V 2 wire 1.5 mA 2 wire 100 mA 3 wire 200 mA Current consumption (on load) 3 wire 10 mA Residual (leakage) current, open state 2 wire 0.5 mA 2 wire 0.2 ms 3 wire 0.3 ms 2 wire 0.3 ms On delay (max.) Off delay (max.) 3 wire 0.7 ms Power-up delay (max.) 5 ms Short circuit protection Yes Overload Yes Radio frequency immunity (RFI) Protective circuitry Electrostatic; transients; impulse (L - indicates level number) Reverse polarity protection Agency Listings 7427 Proximity Sensors Cable Connector 4 (R) IEC 61000-4-3 Level 3 2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L3; 60947.5.2 L3 3 wire: IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L4 Yes E 164869 CCN NRKH CR 44087 Class 3211 03 Options Description 9006PAkk Suffix Extended temperature range cable type only Extended cable length XSZB1kk Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories Description Catalog Number Plastic mounting nuts XSZE230 Connector Cables (M12 or D suffix; U78 or A suffix) Stainless steel mounting nuts XSZE330 Locknut washers, stainless steel XSZE930 XSZCD101Y Micro Conn., 4 pin, 2 m, straight Mounting bracket, 90 steel 9006PA30 XSZCD111Y Micro Conn., 4 pin, 2 m, 90 Mounting bracket, plastic XSZCA101Y Micro Conn., 3 pin, 2 m, straight 0.5" NPT conduit adapter length 2" (50.8mm) XSZCA111Y Micro Conn., 3 pin, 2 m, 90 a XSZB130 Aluminum 7427 Refer to p. 351 for target material correction coefficient Km. For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 253 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, AC/DC; Universal Standard Length XS Tubular Inductive Sensors / 30 mm Diameter, AC/DC; Universal Standard Length * 360 LED indicators 2.75 70 2.02 51.5 2.36 60 2.02 51.5 Features * Extended temperature range * Extended supply voltage range LED * IP68 LED XS1M30kK * AC/DC power supply .51 13 XS1M30k * Patented plastic mounting bracket LED 1.85 47 1.51 38.5 2.95 75 2.12 54 * Connector options * Metal lock nuts for metal or plastic mounting nuts for plastic housing and lock washers included LED * Normally closed (N.C.) output available on versions marked a XS2M30k XS1M30kA * Extensive protective circuitry 2.44 62 LED XS1M30kK Nominal AC or Output Voltage Range Sensing AC/DC Modea Distance AC DC Operating Frequency AC DC SCP Mating Indicator Catalog Connector Style LED Number (see p. 518) 2000 Hz 2000 Hz no yes A C -- -- XS1M30MA230 XS1M30MA250 24-210 V 25 Hz 24-210 V 25 Hz 2000 Hz 2000 Hz no yes B B 13,14 13,14 XS1M30MA230K XS1M30MA250K 24-210 V 25 Hz 24-210 V 25 Hz 2000 Hz 2000 Hz no yes B C 17,20 18,20 XS1M30MA230A XS1M30MA250A 24-210 V 25 Hz 2000 Hz no B -- XS1M30MA230B 24-210 V 25 Hz 24-210 V 25 Hz 1000 Hz 1000 Hz no yes A C -- -- XS2M30MA230 XS2M30MA250 24-210 V 25 Hz 24-210 V 25 Hz 1000 Hz 1000 Hz no yes B B 13,14 13,14 XS2M30MA230K XS2M30MA250K 24-210 V 25 Hz 24-210 V 25 Hz 1000 Hz 1000 Hz no yes B C 18,19 18,19 XS2M30MA230A XS2M30MA250A 24-210 V 25 Hz 1000 Hz no A -- XS4P30MA230 24-210 V 25 Hz 1000 Hz no A 13,14 XS4P30MA230K 24-210 V 25 Hz 1000 Hz no A 18,20 XS4P30MA230A 1000 Hz no B -- XS4P30MA230B Nickel plated brass case Shielded, 2 m (6.6') cable LED XS2M30 kA 10 mm 10 mm AC/DC AC/DC N.O.a N.O.a 24-240 V 24-240 V 24-210 V 25 Hz 24-210 V 25 Hz Shielded, connector - micro style AC 2.75 70 2.36 60 2.02 51.5 10 mm 10 mm 2.02 51.5 N.O.a N.O.a 24-240 V 24-240 V Shielded, connector - mini style 10 mm 10 mm 10 mm XS4P30k230K XS2P30k AC/DC AC/DC AC/DC AC/DC N.O.a N.O.a 24-240 V 24-240 V Shielded, screw terminal connection LED LED AC/DC N.O.a 24-240 V Non-shielded, 2 m (6.6') cable 15 mm 15 mm AC/DC AC/DC N.O.a N.O.a 24-240 V 24-240 V Non-shielded, connector - micro style AC 15 mm 15 mm 2.95 75 2.12 54 Proximity Sensors 2.24 57 1.61 41 1.51 38.5 .51 13 .51 13 * UL Listed, CSA Certified and CE Mark N.O.a N.O.a 24-240 V 24-240 V Non-shielded, connector - mini style 15 mm 15 mm LED AC/DC AC/DC N.O.a N.O.a 24-240 V 24-240 V Plastic case XS4P30k230A Dual Dimensions inches mm AC/DC AC/DC Non-shielded, 2 m (6.6') cable thread M30x1.5 15 mm AC/DC N.O.a 24-240 V Non-shielded, connector - micro style 15 mm AC/DC N.O.a 24-240 V Non-shielded, connector - mini style 15 mm AC/DC N.O.a 24-240 V Non-shielded, screw terminal connector 15 mm a AC/DC N.O.a 24-240 V 24-210 V 25 Hz To order a normally closed (N.C.) version change the A to B, example: XS1M30PA260 to XS1M12PB260. See next page under specifications for LED function. Minimum Mounting Clearances (mm/inches) Face to face Side by side Mounting in a metal support D Facing a metal object H XS1 Shielded XS2/XS4 Non-shielded e e e e: 20/.79 e: 60/2.36 e: 120/4.72 e: 180/7.09 e: 30/1.18 e: 45/1.77 D: 30/1.18, H: 0/0 D: 90/3.54, H: 30/1.18 254 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors 30 mm Diameter, AC/DC; Universal Standard Length XS Tubular Inductive Sensors / 30 mm Diameter, AC/DC; Universal Standard Length Specifications Wiring Connector Micro Mini 1 3 2 3 Mechanical Cable 1 2 Usable sensing rangea Blue Brown Black BU - BN + BK Output Wire color/connector pin 2 wire, AC/DC or AC BN/2 BU/3 Enclosure rating - cable (connector, see p. 518) +/- L1 L2 Tightening torque (max.) -/+ 0 to 8 mm 0 to 12 mm -25 C to +80 C (-13 F to +176 F) NEMA Type IEC Type 3, 4X, 6P, 12, 13 IP68 - P67 for B screw terminals Nickel plated brass PBT PBT 50 N*m 37 (lb-ft) 20 N*m 15 (lb-ft) 25 G, amplitude +/- 2 mm, f = 10-55 Hz Standard temperature range Enclosure material AC/DC Shielded Non-shielded Vibration resistance Shock resistance Standard target size (steel) Nickel plated brass Case Sensing face Plastic Nickel plated brass Plastic (IEC 60068.2.6) (IEC 60068.2.27) Shielded Non-shielded 50 G duration 11 ms 1.18" x 1.18" (30 mm x 30 mm) 1.41" x 1.41" (36 mm x 36 mm) 15% 3% 360 ring LED: Shows output status One LED visible from 4 quadrants: Shows output status 2 LED indicators: Red shows output status Green shows normal operation (SCP only) 22 AWG (0.5 mm2), PvR Differential (% of Sr) Repeatability (% of Sr) LED indicator type A B C Cable 2 wire Voltage range - nominal Voltage limit (including ripple) Voltage drop (across switch), closed state Inrush current Minimum load current AC Maximum load current Residual (leakage) current, open state On delay (max.) Off delay (max.) Power-up delay (max.) Protective circuitry Agency Listings Without SCP With SCP Without SCP With SCP Without SCP With SCP 24 to 240 Vac (50/60 Hz), 24 to 210 Vdc 20 to 264 Vac/Vdc 5.5 V 2A 5 mA 300 mA 200 mA 20 Vdc 58 IEC 60947-5-2 Utilization category DC-13 Vdc > 58 IEC 60947-5-2 Utilization category DC-12 0.6 mA 1.5 mA 0.2 ms 2 ms 0.3 ms 5 ms Without SCP With SCP Without SCP With SCP Short circuit protection Radio frequency immunity (RFI) Electrostatic; transients; impulse E 164869 CCN NRKH 40 ms 70ms 40 ms 70 ms Optionalq IEC 61000-4-3 Level 3 IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3 CR 44087 Class 3211 03 DC (R) 7427 Options Description Suffix Extended temperature range cable type only 9006PAkk Extended cable length Down to -40 C (-40 F) 16.4 ft. (5 meter) cable 32.8 ft. (10 meter) cable TF L1 L2 Accessories XSZB1kk Connector Cables (U20 or K suffix; U78 or A suffix) XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 Description Catalog Number Plastic mounting nuts Metal mounting nuts and lock washers Mounting bracket, 90 steel Mounting bracket, plastic 0.5" NPT conduit adapter length 2" (50.8 mm) XSZE230 XSZE130 9006PA30 XSZB130 7427 a q Aluminum Refer to p. 351 for target material correction coefficient Km. For devices without SCP, see p. 298 for protective fuses. XSZCA101Y Mini Conn., 3 pin, 2 m, straight XSZCA111Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 255 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Electrical Proximity Sensors XS Tubular Inductive Sensors Economy D Series - DC, AC thread M8x1 XS Tubular Inductive Sensors / Economy D Series - DC, AC Features Entire family of proximity sensors dedicated to OEMs and "just enough" applications. thread * DC tubular body style ranging from 6.5 mm to 30 mm diameter, in 3 wire, N.O. output M12x1 * AC tubular body style ranging from 12 mm to 30 mm diameter, in 2 wire, N.O. output * Brass metal case with either 2 meter cable or connector options thread M18x1 * Shielded and non-shielded versions available * Mounting nuts included * Sold in multiples of 10 easy to open bags thread M30x1.5 a = Overall Length (mm) b = Threaded Section (mm) c = for Non-shielded Sensors (mm) Operating Load Current Frequency Maximum Maximum 6.5 mm, Shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-1.5 mm Circuit Type Output Mode Voltage Range Voltage Drop Maximum PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 50 mA 50 mA Catalog Number 3000 Hz 3000 Hz XS1L06PA140 XS1L06NA140 3000 Hz 3000 Hz XS1D08PA140 XS1D08NA140 8 mm, Shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-1.5 mm PNP NPN b c Proximity Sensors a N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 50 mA 50 mA 8 mm, Shielded, DC-Micro Style Connector a-Nominal Sensing Distance-1.5 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 50 mA 50 mA 3000 Hz 3000 Hz XS1D08PA140D XS1D08NA140D 2000 Hz 2000 Hz XS1D12PA140 XS1D12NA140 12 mm, Shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-2 mm PNP NPN Dimensions Cable 6.5 mm Connector Cable 8 mm Connector Cable 12 mm Connector Cable 18 mm Connector Cable 30 mm Connector a IN mm 1.65 42.0 - - 1.65 42.0 2.42 61.4 1.66 42.2 2.09 53.0 2.06 52.2 2.52 64.0 2.05 52.0 - - b c IN mm IN mm - - - - - - - - 1.60 40.6 - - 1.56 39.6 - - 1.57 40.0 .26 7 1.56 39.6 - - 1.95 49.6 - - 1.96 49.7 - - 1.95 49.6 - - - - - - N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 12 mm, Shielded, DC-Micro Style Connector a-Nominal Sensing Distance-2 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 2000 Hz 2000 Hz XS1D12PA140D XS1D12NA140D 12 mm, Non-shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-4 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 1000 Hz 1000 Hz XS2D12PA140 XS2D12NA140 12 mm, Non-shielded, DC-Micro Style Connector-Nominal Sensing Distance-4 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 1000 Hz 1000 Hz XS2D12PA140D XS2D12NA140D 25 Hz XS1M12FA264 1000 Hz 1000 Hz XS1D18PA140 XS1D18NA140 12 mm, Shielded, AC-2 Meter (6') Cable-Nominal Sensing Distance-2 mm 2 wire N.O. 24 to 240 Vac 7V 200 mA 18 mm, Shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-5 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 18 mm, Shielded, DC-Micro Style Connector a-Nominal Sensing Distance-5 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 1000 Hz 1000 Hz XS1D18PA140D XS1D18NA140D 18 mm, Non-shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-8 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 250 Hz 250 Hz XS2D18PA140 XS2D18NA140 18 mm, Non-shielded, DC-Micro Style Connector a-Nominal Sensing Distance-8 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 250 Hz 250 Hz XS2D18PA140D XS2D18NA140D 25 Hz XS1M18FA264 200 Hz 200 Hz XS1D30PA140 XS1D30NA140 18 mm, Shielded, AC-2 Meter (6') Cable-Nominal Sensing Distance-5 mm 2 wire N.O. 24 to 240 Vac 4.5 V 300 mA 30 mm, Shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-10 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 30 mm, Shielded, DC-Micro Style Connector a-Nominal Sensing Distance-10 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 200 Hz 200 Hz XS1D30PA140D XS1D30NA140D 30 mm, Non-shielded, DC-2 Meter (6') Cable-Nominal Sensing Distance-15 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 60 Hz 60 Hz XS2D30PA140 XS2D30NA140 30 mm, Non-shielded, DC-Micro Style Connector a-Nominal Sensing Distance-15 mm PNP NPN N.O. N.O. 12 to 24 Vdc 12 to 24 Vdc 3V 3V 100 mA 100 mA 60 Hz 60 Hz XS2D30PA140D XS2D30NA140D 25 Hz XS1M30FA264 30 mm, Shielded, AC-2 Meter (6') Cable-Nominal Sensing Distance-10 mm 2 wire a N.O. 24 to 240 Vac 4.5 V 300 mA See p. 517 for matching connector cables. 256 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors Economy D Series - DC, AC XS Tubular Inductive Sensors / Economy D Series - DC, AC Specifications Wiring Cable 3 1 2 Blue Brown Black BU - BN + BK Output Mechanical DC Diameter 0.25" 0.31" (6.5 mm) (8 mm) Usable Sensing Range a AC 0.47" (12 mm) Shielded 0.04" (1.2mm) 0.04" 0.06" 0.16" (1.2 mm) (1.6 mm) (4 mm) Non-shielded - - Temperature Range + BK/4 - BU/3 3 Wire, NPN, NO + BN/1 NPN BK/4 - BU/3 0.47" (12 mm) 0.7" (18 mm) 0.31" (8 mm) 0.06" 0.16" (1.6 mm) (4 mm) 0.31" (8 mm) - - - 1.18" (30 mm) -13 F to +158 F (-25 C to +70 C) NEMA Type Enclosure Rating 1.18" (30 mm) 0.12" 0.25" 0.47" (3.2 mm) (6.4 mm) (12 mm) 3 Wire, PNP, NO BN/1 PNP 0.7" (18 mm) 1 CENELEC Type IP66 (connector style is IP65) IP67 Vibration 25 G, amplitude =/- 2 mm, f = 10-55 Hz Shock Resistance 50 G, for 11 ms Maximum Differential (% of Sr) 15% Maximum Repeatability (% of Sr) 3% LED Indicator Type One, mounted at rear (connector style is 4 viewing ports at 90 degrees) Enclosure Material Brass Wiring 3 x 0.34 mm2 (8 mm = 3 x 0.11 mm2) 2 x 0.34 mm2 Voltage Range 12 to 24 Vdc 24 to 240 Vac Voltage Limit (Including Ripple) 10 to 30 Vdc 20 to 264 Vac Current Consumption (Maximum) (No Load) 10 mA - Electrical 2 Wire, AC, NO BN BU Maximum Leakage (Residual) Current-open State - 1.5 mA Voltage Drop (Closed State) 3V 7V Power-up Delay (Maximum) 5 ms 5 ms 5 ms 5 ms 10 ms 40 ms On Delay (Maximum) 0.5 ms 0.5 ms 0.5 ms 1 ms 2 ms 10 ms Off Delay (Maximum) 1 ms 1 ms 0.5 ms 2 ms 6 ms Protective Circuitry Short Circuit Protection Yes Overload Protection Yes Agency Listings (R) a 4.5 V Proximity Sensors Connector 4 15 ms No No E 164869 CCN NRKH CR 44087 Class 3211 03 Refer to p. 351 for target material correction coefficient Km. Accessories Description For Sensor Diameter Catalog Number 0.25" (6.5 mm) 0.31" (8 mm) XSZB165 XSZB108 XSZB112 9006PA12 XSZB118 9006PA18 XSZB130 9006PA30 XSZE108 XSZE112 XSZE118 XSZE130 0.47" (12 mm) Mounting Brackets 0.7" (18 mm) 1.18" (30 mm) 0.31" (8 mm) 0.47" (12 mm) 0.7" *18 mm) 1.18" (30 mm) XSZB1kk Mounting Nuts 9006PAkk Minimum Mounting Clearances (mm/inches) Face to face Side by side Facing a metal object Mounting in a metal support D H XSZEkkk Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XS1L06 XS1D08 XS1D/M12 XS2D12 XS1D/M18 XS1D/M30 e e e IN 0.12 0.12 0.16 0.63 0.39 0.79 e mm 3 3 4 16 10 20 IN 0.71 0.71 0.94 1.89 2.36 4.72 e mm 18 18 24 48 60 120 IN 0.18 0.18 0.24 0.47 0.59 1.18 e mm 4.5 4.5 6.0 12.0 15.0 30.0 IN 0.31 0.31 0.47 1.42 0.59 1.18 d mm 8 8 12 36 15 30 IN 0 0 0 0.31 0 0 h mm 0 0 0 8 0 0 XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 257 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Tubular Inductive Sensors Extended Range - AC/DC, DC XS Tubular Inductive Sensors / Extended Range - AC/DC, DC Features * Extended range feature available in Universal AC/DC, or DC only sensors, where previously only available in DC * AC/DC has same extended sensing range as in DC only sensors * Available in moulded cable or connector versions * rugged IP68 Nickel plated brass casing thread a = Overall Length (mm) b = Threaded Section (mm) M8x1 * Metal lock nuts included in carton thread M12x1 b thread a M18x1 a Proximity Sensors Cabled version Nano connector Micro connector Cabled version 8 mm Nano connector Micro connector Cabled version 12 mm Micro connector Cabled version 18 mm Micro connector Mini connector Cabled version 30 mm Micro connector 6.5 mm AC/DC mm in. - - - - - - - - - - - - 50 1.96 61 2.4 60 2.36 70 2.75 - - 60 2.36 70 2.75 DC mm 33 42 45 33 42 45 33 48 33.5 48 - 40.5 50 AC/DC mm in. - - - - - - - - - - - - 42 1.65 40 1.57 51.5 2.02 51.5 2.02 - - 51.5 2.02 51.5 2.02 DC mm 30 34 24 26 26 24 26 25 26 26 - 32 32 in. 1.29 1.65 1.77 1.29 1.65 1.77 1.29 1.88 1.31 1.88 - 1.59 1.96 Voltage Load Operating Drop Current Frequency Max. Max. Max. 6.5mm Diameter, DC, Shielded - Nominal Sensing Distance - 2mm Circuit Type Output Mode PNP NPN PNP NPN PNP NPN N.O. N.O. N.O. N.O. N.O. N.O. Voltage Range 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 2.6 V 2.6 V 2.6 V 2.6 V 2.6 V 2.6 V 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 2500 Hz 2500 Hz 2500 Hz 2500 Hz 2500 Hz 2500 Hz Connection a Catalog Number 2 meter (6') cable 2 meter (6') cable Nano Style Connector Nano Style Connector Micro Style Connector Micro Style Connector XS1L06PA349 XS1L06NA349 XS1L06PA349S XS1L06NA349S XS1L06PA349D XS1L06NA349D 2 meter (6') cable 2 meter (6') cable Nano Style Connector Nano Style Connector Micro Style Connector Micro Style Connector XS1N08PA349 XS1N08NA349 XS1N08PA349S XS1N08NA349S XS1N08PA349D XS1N08NA349D 2 meter (6') cable 2 meter (6') cable Micro Style Connector Micro Style Connector XS1N12PA349 XS1N12NA349 XS1N12PA349D XS1N12NA349D 8mm Diameter, DC, Shielded - Nominal Sensing Distance - 2.5mm PNP NPN PNP NPN PNP NPN N.O. N.O. N.O. N.O. N.O. N.O. 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 2.6 V 2.6 V 2.6 V 2.6 V 2.6 V 2.6 V 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 2500 Hz 2500 Hz 2500 Hz 2500 Hz 2500 Hz 2500 Hz 12mm Diameter, DC, Shielded - Nominal Sensing Distance - 4mm PNP NPN PNP NPN N.O. N.O. N.O. N.O. 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 2V 2V 2V 2V 200 mA 200 mA 200 mA 200 mA 2500 Hz 2500 Hz 2500 Hz 2500 Hz 12mm Diameter, Universal AC/DC, Shielded - Nominal Sensing Distance - 4mm 2 wire 2 wire N.O. N.O. 12- 24 Vdc 12- 24 Vdc 5.5 V 5.5 V 200mA 200mA 25 Hz /1000 Hz 25 Hz /1000 Hz 2 meter (6') cable Micro Style Connector XS1M12MA239 XS1M12MA239K 2 meter (6') cable 2 meter (6') cable Micro Style Connector Micro Style Connector XS1N18PA349 XS1N182NA349 XS1N18PA349D XS1N18NA349D 18mm Diameter, DC, Shielded - Nominal Sensing Distance - 10mm bf Cabled version Nano connector Micro connector Cabled version 8 mm Nano connector Micro connector Cabled version 12 mm Micro connector Cabled version 18 mm Micro connector Mini connector Cabled version 30 mm Micro connector 6.5 mm f * 360 LED for complete visibility in. 1.18 1.33 0.94 1.02 1.02 0.94 1.02 0.98 1.02 1.02 - 1.25 1.25 For 6.5mm diameter, b = smooth length PNP NPN PNP NPN N.O. N.O. N.O. N.O. 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 2V 2V 2V 2V 200 mA 200 mA 200 mA 200 mA 1000 Hz 1000 Hz 1000 Hz 1000 Hz 18mm Diameter, Universal AC/DC, Shielded - Nominal Sensing Distance - 10mm 2 wire 2 wire 2 wire N.O. N.O. N.O. 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 5.5 V 5.5 V 5.5 V 200 mA 200 mA 200 mA 25 Hz /1000 Hz 25 Hz /1000 Hz 25 Hz /1000 Hz 2 meter (6') cable Micro Style Connector Mini Style Connector XS1M18MA239 XS1M18MA239K XS1M18MA239A 2 meter (6') cable 2 meter (6') cable Micro Style Connector Micro Style Connector XS1N30PA349 XS1N30NA349 XS1N30PA349D XS1N30NA349D 30mm Diameter, DC, Shielded - Nominal Sensing Distance - 20mm PNP NPN PNP NPN N.O. N.O. N.O. N.O. 12- 24 Vdc 12- 24 Vdc 12- 24 Vdc 12 - 24 Vdc 2V 2V 2V 2V 200 mA 200 mA 200 mA 200 mA 500 Hz 500 Hz 500 Hz 500 Hz 30mm Diameter, Universal AC/DC, Shielded - Nominal Sensing Distance - 20mm 2 wire 2 wire a N.O. N.O. 24 to 240 V 24 to 240 V 5.5 V 5.5 V 200 mA 200 mA 25 Hz /1000 Hz 25 Hz /1000 Hz 2 meter (6') cable Mini Style Connector XS1M30MA239 XS1M30MA239A See p. 518 for matching connector cables. Minimum Mounting Clearances (mm/inches) Side by side Facing a metal object Face to face Mounting in a metal support Mounted in a metal support D D X H e e 6.5 mm 8 mm 12 mm 12 mm (AC/DC) 18 mm 18 mm (AC/DC) 30 mm 5 mm (.196") 5 mm (.196") 8 mm (.314") 8 mm (.314") 20 mm (.787") 20 mm (.787") 40 mm (1.57") e 30 mm (1.18") 30 mm (1.19") 48 mm (1.88") 48 mm (1.88") 96 mm (3.77") 96 mm (3.77") 240 mm (9.44") 7.5 mm (.29") 7.5 mm (.29") 12 mm (.47") 12 mm (.47") 30 mm (1.18") 30 mm (1.18") 60 mm (2.36") d = 10 mm (.393") d = 10 mm (.393") d = 14 mm (.551") d = 14 mm (.551") d = 28 mm (1.10") d = 28 mm (1.10") d = 50 mm (1.96") h = 1.6 mm (.062") h = 1.6 mm (.062") h = 2.4 mm (.094") h = 1.2 mm (.047") h = 3.6 mm (.141") h = 1.8 mm (.070") h = 6 mm (.236") d = 6.5 mm (.255") d = 8 mm (.314") d = 12 mm (.472") d = 12 mm (.472") d = 18 mm (.708") d = 18 mm (.708") d = 30 mm (1.18") x = 1.3 mm (.051") x = 1.6 mm (.062") x = 1.6 mm (.062") x = 1.6 mm (.062") x = 3.6 mm (.141") x = 1.8 mm (.070") x = 6 mm (.236") 258 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors Extended Range - AC/DC, DC XS Tubular Inductive Sensors / Extended Range - AC/DC, DC Specifications Wiring 2 Cable Blue Brown Black 3 3 2 BU - BN + BK Output Mechanical 6.5 mm 8 mm 12 mm 18 mm 30 mm Usable sensing range a 0 to 0.08" (0 to 2 mm) 0 to 0.08" (0 to 2 mm) 0 to 0.12" (0 to 3.2 mm) 0 to 0.31" (0 to 8 mm) 0 to 0.62" (0 to 16 mm) Temperature range Enclosure rating wire color/connector pin 2 wire, AC/DC for connector version only L1 BN/2 +/- AC/DC BU/3 Connector Nano Micro 4 4 3 -/+ 3 Blue Brown Black 2 3, 4x, 6p, 12, 13 IEC Type IP68 (except connectors) Max tightening torque -- Vibration 25 G, amplitude +/- 2mm, f = 10 - 55 Hz 50 G, duration 11ms" Standard target size (steel) (mm) 6.5x6.5x1 Max Differential (% of Sr) 15% Max Repeatability (% of Sr) 3% Cable Connector Enclosure material BU - BN + BK Output 5 N*m 3.7 (lb-ft) 6 N*m 4.4 (lb-ft) 15 N*m 11 (lb-ft) 40 N*m 29.5 (lb-ft) Shock resistance LED indicator type Cable 1 1 L2 -13 F to + 25 F (-25 C to +70 C) NEMA Type 8x8x1 30x30x1 One LED, visible from 4 quadrants Nickel plated brass Wiring 27 AWG 27 AWG 22 AWG 22 AWG 22 AWG Cable material PvR PvR PvR PvR PvR AC / DC AC / DC AC / DC Electrical BN/1 BN/1 + + NPN BK/4 NO BK/2 NC BK/4 NO BK/2 NC BU/3 18x18x1 360 ring LED, visible from all quadrants 3 wire, DC, NO or NC PNP 12x12x1 BU/3 Voltage range 24 V to 240 Vac/dc, 12 V to 24 Vdc Voltage limit (including ripple) 20 V to 264 Vac/dc, 10 to 38 Vdc Voltage Drop (max.) 2.6 V 2.6 V 5.5 V / 2.6 V 5.5 V / 2 V 5.5 V / 2 V Max. Leakage (Residual) Current -open state, AC -- -- 0.8 mA 0.8 mA 0.8 mA Current Consumption (no load) 10 mA Power-up delay (max.) 5 ms 5 ms 20ms / 5 ms 25 ms / 5 ms 25 ms / 5 ms On delay (max.) 0.2 ms 0.2 ms 0.5 ms / 0.2 ms 0.5 ms 0.3 ms Off delay (max.) 0.2 ms 0.2 ms 0.2 ms Protective Circuitry 0.5 ms / 0.6 ms 0.5 ms / 0.7 ms 2 ms / 1.4 ms Short circuit protection yes Overload protection yes Reverse polarity protection yes Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic, Transients, Impulse IEC 61000-4-2 Level 3; IEC 61000-4-4 Level 3; 60947.5.2 Level 3 Agency Listings (R) XSZB1kk a 9006PAkk Refer to p. 351 for target material correction coefficient Km. Options Description XSZEkkk Suffix 16.4 ft. (5 meter) cable L2 32.8 ft. (10 meter) cable L5 Accessories Description For Sensor Diameter Catalog Number 0.25" (6.5 mm) XSZB165 0.31" (8 mm) XSZB108 0.47" (12 mm) Connector Cables (M8 or S suffix; M12 or D suffix; U20 or K suffix; U78 or A suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 Mounting Brackets 0.7' (18 mm) 1.18" (30 mm) 0.31" (8 mm) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 Mounting Nuts 0.47" (12 mm) XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 0.7' (18 mm) XSZB112 9006PA12 XSZB118 9006PA18 XSZB130 9006PA30 XSZE108 XSZE112 XSZE118 XSZE130 XSZCA901Y Mini Conn., 3 pin, 2 m, straight XSZCA911Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 259 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Connector Micro Mini 1 1 Proximity Sensors XS Inductive Sensors 18 mm, Ferrous Only - DC XS Inductive Sensors / 18 mm, Ferrous Only - DC M18x1 2.36 60 2.02 51.5 thread Features: * Ideal for machining, sorting applications * Responds only to ferrous metals, ignoring non ferrous metals such as Aluminum * Stainless steel body LED * Cable and micro-style connector versions offered t XS1M18PAS40 Circuit Type Output Mode Voltage Range Load Current Max. Operating Frequency Max. Catalog Number 1000 Hz XS1M18PAS40 1000 Hz XS1M18PAS40D Shielded - 2 meter (6.6') cable - Nominal Sensing Distance - 5 mm N.O. 12-24 Vdc 200 mA Shielded - micro-style connector t - Nominal Sensing Distance - 5 mm PNP 2.75 70 2.02 51.5 PNP t N.O. 12-24 Vdc 200 mA See p. 518 for matching connector cables LED XS1M18PAS40D Dual Dimensions inches mm Proximity Sensors Minimum Mounting Clearances (mm/inches) Face to face Side by side Mounting in a metal support D Facing a metal object H e e e e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0 260 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors 18 mm, Ferrous Only - DC XS Inductive Sensors / 18 mm, Ferrous Only - DC Specifications Wiring Mechanical Cable Connector 4 Usable sensing range a 3 1 Blue Brown Black 2 BU - BN + BK Output 3 Wire, PNP, NO BN/1 + PNP BK/4 NO Enclosure rating - -13 to 158 F (-25 to 70 C) IEC Type IP68 (except connector version) Tightening torque (max.) 50 N*m 37 (lb-ft) Standard target size (steel) 18 x 18 x 1 Differential (% of Sr) 15% Repeatability (% of Sr) LED indicator type BU/3 0 - 4 mm (.16") Temperature range 3% Cable version 360 ring LED Connector version 4 LED windows at 90 degrees Enclosure Material Stainless steel Wiring 22 AWG (0.34 mm2), PvR cable Electrical Voltage range 12 to 24 Vdc Voltage limit (including ripple) 10 to 38 Vdc Voltage drop (across switch, closed state) 2.6 V Current Consumption (no load) 15 mA Maximum Load Current 200 mA Power-up delay (max.) 5 ms On delay (max.) 0.3 ms Protective Circuitry 0.7 ms Short circuit protection Yes Overload protection Yes Reverse polarity protection Yes Radio frequency immunity (RFI) Yes Electrostatic discharges Yes Fast transients (motor start/stop interference) Yes Impulse voltages (lightning, etc.) Yes Agency Listings (R) E 164869 CCN NRKH Proximity Sensors Off delay (max.) CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40+ C (-40+ F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories 7428k Description Catalog Number Stainless steel mounting nuts XSZE318 Mounting bracket, 90 steel 9006PA18 Mounting bracket, plastic 0.5" NPT conduit adapter length 2" (50.8 mm) a XSZB118 Aluminum 7428 Stainless 74282 Refer to p. 351 for target material correction coefficient Km 9006PAkk XSZB1kk Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories. . . . . . . . . . . . . . . . . . . . . page 298, 316 261 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Inductive Sensors 18 mm, Non Ferrous Only - DC XS Inductive Sensors / 18 mm, Non Ferrous Only - DC M18x1 2.36 60 2.02 51.5 thread Features: * Response to non ferrous metals only, such as Aluminum, ignoring ferrous material such as steel * Ideal for mounting in areas where metal is close * Stainless steel body LED * Cable and micro-style connector versions offered t XS1M18PAS20 Circuit Type Output Mode Voltage Range Load Current Max. Operating Frequency Max. Catalog Number 1000 Hz XS1M18PAS20 1000 Hz XS1M18PAS20D Shielded - 2 meter (6') cable - Nominal Sensing Distance - 5 mm N.O. 12-24 Vdc 200 mA Shielded - micro-style connector t - Nominal Sensing Distance - 5mm 2.75 70 2.02 51.5 PNP PNP t N.O. 12-24 Vdc 200 mA See p.518 for matching connector cables LED XS1M18PAS20D Dual Dimensions inches mm Proximity Sensors Minimum Mounting Clearances (mm/inches) Face to face Side by side Mounting in a metal support D Facing a metal object H e e e e: 10/.39 e: 60/2.36 e: 15/.59 D: 18/.71, H: 0/0 262 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors 18 mm, Non Ferrous Only - DC XS Inductive Sensors / 18 mm, Non Ferrous Only - DC Specifications Wiring 3 1 Mechanical Cable Connector 4 Blue Brown Black 2 Usable sensing range a BU - BN + BK Output 3 Wire, PNP, NO BN/1 + PNP BK/4 NO Enclosure rating BU/3 -13 to 158 F (-25 to 70 C) IEC Type IP68 (except connector version) Tightening torque (max.) 50 N*m 37 (lb-ft) Standard target size (aluminum) 18 x 18 x 1 Differential (% of Sr) 15% Repeatability (% of Sr) LED indicator type - 0 - 4 mm (.16") Temperature range 3% Cable version 360 ring LED Connector version 4 LED windows at 90 degrees Enclosure material Metal Wiring 22 AWG (0.34 mm2), PvR cable Electrical Voltage range 12 to 24 Vdc Voltage limit (including ripple) 10 to 38 Vdc Voltage drop (across switch, closed state) 2.6 V Current Consumption (no load) 15 mA Maximum Load Current 200 mA Power-up delay (max.) 5 ms On delay (max.) 0.3 ms Protective Circuitry 0.7 ms Short circuit protection Yes Overload protection Yes Reverse polarity protection Yes Radio frequency immunity (RFI) Yes Electrostatic discharges Yes Fast transients (motor start/stop interference) Yes Impulse voltages (lightning, etc.) Yes Agency Listings (R) E 164869 CCN NRKH Proximity Sensors Off delay (max.) CR 44087 Class 3211 03 Options Description Suffix Extended temperature range (cable type only) Extended cable length Down to -40 C (-40 F) TF 16.4 ft. (5 meter) cable L1 32.8 ft. (10 meter) cable L2 Accessories Description Catalog Number Stainless steel mounting nuts XSZE318 Mounting bracket, 90 steel 9006PA18 Mounting bracket, plastic 7428k 0.5" NPT conduit adapter length 2" (50.8 mm) a XSZB118 Aluminum 7428 Stainless 74282 Refer to p. 351 for target material correction coefficient Km 9006PAkk XSZB1kk Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 263 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Inductive Sensors Ferrous/Non-Ferrous; Universal, DC XS Inductive Sensors / Ferrous/Non-Ferrous; Universal, DC Features 2.02 51.5 * Detects all types of metals at the same sensing distance, whereas, metals such as aluminum and copper require standard sensor to be closer (see chart on next page). 2.36 60 2.02 51.5 2.75 70 LED XS1M18KPM40 4 x 90 LED * All are suitable for flush mounting in metal. XS1M18KPM40D 2.02 51.5 2.36 60 thread * Universal selectable output: PNP, NPN, N.O. and N.C. * Available with 2 meter cable, micro style connector or 2.6' pigtail with micro connector for very aggressive chemical environments. M30x1.5 XS1M30KPM40 * Ideal for "drop in" replacements for tubular and limit switch style standard sensors. M18x1 thread LED * Body types include 18 mm nickel plated brass housing, 30 mm stainless steel housing, and limit switch style in plastic housing. * Tubular bodies have 360 visibility LED (four LED windows at 90 for connector version). * Metal mounting nuts included with tubular versions. * UL Listed, CSA Certified and CE Mark. 2.02 51.5 2.75 70 Sensing Circuit Distance Type Output Mode Voltage Range Connection Load Operating Current Frequency Max Catalog Number 12-24 Vdc 12-24 Vdc 2 m (6.6') cable Micro Style DC Connector t 200 mA 200 mA 1000 Hz 1000 Hz XS1M18KPM40 XS1M18KPM40D 2 m (6.6') cable Micro Style DC Connector, 0.8 m (2.6') pigtail t 200 mA 1000 Hz XS1M30KPM40 200 mA 1000 Hz XS1M30KPM40LD Screw Terminal 200 mA 1000 Hz XS7C40KPM40 Shielded, 18 mm Diameter 5 mm 5 mm Proximity Sensors LED PNP/NPN N.O./N.C. PNP/NPN N.O./N.C. Shielded, 30 mm Diameter XS1M30KPM40LD 10 mm PNP/NPN N.O./N.C. 12-24 Vdc 10 mm PNP/NPN N.O./N.C. 12-24 Vdc Shielded, Limit Switch Style Body 15 mm 1.57 40 1.57 40 t PNP/NPN N.O./N.C. 12-24 Vdc See p. 518 for matching connector cables Side by side Face to face Facing a metal object Mounting in a metal support d 2.36 60 4.6 117 1.77 45 Minimum Mounting Clearances (mm/inches) h e e 1.18 30 1.57 40 XS1M18 XS1M30 e = 0.40 in. (10 mm) e = 0.79 in. (20 mm) (1) Output LED (Yellow) (2) 0.5" NPT conduit opening (3) Oblong mounting hole: 0.21" x 0.28" (5.3mm x 7mm) e XS7C40KPM40 e = 1.57 in. (40 mm) e e = 2.36 in. (60 mm) e = 4.72 in. (120 mm) e = 0.59 in. (15 mm) e = 1.18 in. (30 mm e d = 0.71 in. (18 mm), h = 0 d = 1.18 in. (30 mm), h = 0 e e = 4.72 in. (120 mm) e = 1.77 in. (45 mm) Dual Dimensions inches mm 264 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors Ferrous/Non-Ferrous; Universal, DC XS Inductive Sensors / Ferrous/Non-Ferrous; Universal, DC Specifications Wiring Mechanical Standard Temperature Range 32 to 122 F (0 to 50 C) Tubular, cable3, 4X, 6P, 12,13 Tubular, connector See connector rating Limit switch body 4, 6P, 12 Tubular, cable IEC IP68 Tubular, connectorSee connector rating Limit Switch BodyIEC IP67 XS1M18 Nickel Plated Brass XS1M30 Stainless Steel XS7 ABS Plastic XS1M1835 N*m XS1M3050 N*m 7 gn, amplitude 1mm (f = 10 Hz to 42 Hz) 30 gn, duration 11 ms 0.7" x 0.7" (18 mm x 18 mm) 1.18" x 1.18" (30 mm x 30 mm) 1.77" x 1.77" (45 mm x 45 mm) 15% 3% 360 ring LED 4 LED windows at 90 360 ring LED LED power On 4 wire #22 AWG (0.34 mm2), PvR 4 pin Micro Style DC 4 wire #22 AWG (0.34 mm2), PvR 4 pin Micro Style DC, 0.8 m (2.6') pigtail, PvR #14 AWG Screw Terminals 3 1 Blue Brown Black 2 BU - BN + BK Output NEMA Type Enclosure Rating IEC Type 4 wire programmable NO or NC selectable output Enclosure Material Case BN/1 (NO), BU/3 (NC) + PNP Tightening torque (max.) WH/2 Vibration resistance Shock resistance BK/4 BU/3 (NO), BN/1 (NC) Standard Target Size BN/1 (NO), BU/3 (NC) Differential (max) Repeatability (max) + NPN WH/2 LED indicator type BK/4 - BU/3 (NO), BN/1 (NC) Connection (IEC 60068-2-6) (IEC 60068-2-27) 0.7" (18 mm) 1.18" (30 mm) Limit switch (% of Sr.) (% of Sr.) Tubular, cable Tubular, connector Tubular, pigtail Limit switch body 10.7" (8 mm) cable 0.7" (18 mm) connector 1.18" (30 mm) cable 1.18" (30 mm) pigtail Limit switch body Proximity Sensors Cable Connector 4 Electrical Voltage Range Voltage Limit (including ripple) Voltage Drop (across switch) closed state (max) Current consumption (no load) (max) Load Current (max) Operating frequency (max) On delay (max) Off delay (max) Power-up delay (max) Short circuit protection Overload protection Reverse polarity protection Radio Frequency Immunity (RFI) Protective circuitry Electrostatic, Transients, Impulse E 164869 Agency Listings CCN NRKH 12 - 24 Vdc 10 - 38 Vdc 2.6 V 15 mA 200 mA 1000 Hz. 0.3 ms 0.7 ms 5 ms Yes Yes Yes IEC 60947-5-2 and NEMA ICS 5, Part 4 CR 44087 Class 3211 03 (R) Accessories XSZB1kk 9006PAkk XSZEkkk Size Description Catalog Number 18 mm 18 mm 18 mm 30 mm 30 mm 30 mm Metal mounting nuts Metal mounting bracket Plastic mounting bracket Stainless steel mounting nuts Metal mounting bracket Plastic mounting bracket XSZE118 9006PA18 XSZB118 XSZE330 9006PA30 XSZB130 Standard sensor technology requires an adjustment of up to 70% of the sensing distance to detect various metals. Because the Ferrous/Non-Ferrous sensor detects all metals at the same distance, compensation is no longer needed. A smaller device can now perform at a range comparable to a larger sized or non-shielded device. Standard vs. Fe/NonFe Prox Sensing Range (%) 100 90 80 70 60 std 50 Fe/NFe 40 30 20 Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 10 0 Mag. Steel For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 304 Stainless Steel Alu Cu 265 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS5L8 Inductive Sensors Miniature, Rectangular, DC XS5L8 Inductive Sensors / Miniature, Rectangular, DC Features: * 90 degree sensing, for mounting in restricted spaces with face at end or center * PNP/NPN, N.O. Output * 360 ring or LED indicator visible from 4 quadrants * Small, 0.13" x 0.13" x 1.7" (8 mm x 8 mm x 43 mm) square metal housing * Mount side by side with no interference * UL Listed and CSA Certified Sensing Face XS5L81 Circuit Type Output Mode Voltage Range Max. Load Current Max. Operating Frequency Max. Catalog Number 1.5 mm Nominal Sensing Distance, 2 M (6.6') cable XS5L81***S Top PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81PA140 Top NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81NA140 1.5 mm Sensing Distance, Nano style Connector t Top PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81PA140S Top NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L81NA140S 1.5 mm Nominal Sensing Distance, 2 M (6.6') cable PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82PA140 Center NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82NA140 1.5 mm Sensing Distance, Nano style Connector t Center PNP N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82PA140S Center NPN N.O. 10-30 Vdc 100 mA 2500 Hz XS5L82NA140S t See p. 518 for matching connector cables XS5L82 Minimum Mounting Clearances XS5L82***S 0" 0 mm 0.7" 18 mm Dimensions XS5 L81/82kkk .12 3 = .39 10 .31 8 .18 4.7 XS5L81/82 1.69 43 1.93 49 .79 20 2 x M3 = Proximity Sensors Center LEDS LED M8 Dual Dimensions inches mm 266 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS5L8 Inductive Sensors Miniature, Rectangular, DC XS5L8 Inductive Sensors / Miniature, Rectangular, DC Specifications Wiring 4 1 Mechanical Cable Connector Blue Brown Black 3 BU - BN + BK Output 3 Wire, PNP, NO 1.2 mm Temperature range -13 to 158 F (-25 to 70 C) Enclosure rating + BK/4 NO IEC Type IP67 (connector version depends on connector) Differential (% of Sr) 20% Repeatability (% of Sr) 3% LED indicator BN/1 PNP Usable sensing range a Cable Type 360 ring Connector type 90, or visible from 4 quadrants Enclosure material Metal Wiring 27 AWG (0.11 mm2), PvR cable Electrical 3 Wire, NPN, NO BN/1 + NPN BK/4 NO - Voltage range 12 to 24 Vdc Voltage limit (including ripple) 10 to 30 Vdc Voltage drop (across switch, closed state) 2.6 V Maximum Load Current 100 mA Current consumption (max.)(no load) 10 mA Residual (leakage) current, open state 0.1 mA Power-up delay (max.) 5 ms On delay (max.) 0.5 ms Off delay (max.) 1 ms Physical Characteristics BU/3 Protective Circuitry Short circuit protection yes Overload protection yes Reverse polarity protection Agency Listings (R) E 164869 CCN NRKH Proximity Sensors BU/3 yes CR 44087 Class 3211 03 Options Description Suffix 5 meter (16') Cable L1 10 meter (33') Cable L2 a Refer to p. 351 for target material correction coefficient Km Connector Cables (M8 or S suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 267 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS7/8H Miniature, Inductive Sensor Sub-compact Block Style, DC XS7/8H Miniature, Inductive Sensor / Dub-compact Block Style, DC Miniature micro switch type inductive proximity sensor for industrial applications. Features: * Very fast response time * Rugged plastic housing * Extremely small for mounting in difficult to access locations * Easy replacement of mechanical micro-switches with matching footprint (V3) * Longer life and substantially faster speed than mechanical switches * High levels of radio frequency immunity (RFI), electrostatic discharge, fast transients and impulse voltage protected * UL Listed, CSA Certified and CE Mark .62 16 .40 10.3 Circuit type Output mode Voltage range Load current (max.) Operating frequency Catalog Number 2 mm (.078") sensing range - Shielded .11 2.75 .12 3.1 DC models, 3 wire 2 m (6.6') cable PNP N.O. 10-30 Vdc 200 mA 5000 Hz XS7H10PA340 NPN N.O. 10-30 Vdc 200 mA 5000 Hz XS7H10NA340 Proximity Sensors .14 3.5 3 mm (.118") sensing range - Non-shielded .88 22.5 1.10 28 DC models, 3 wire 2 m (6.6') cable PNP N.O. 10-30 Vdc 200 mA 5000 Hz XS8H10PA340 NPN N.O. 10-30 Vdc 200 mA 5000 Hz XS8H10NA340 Minimum Mounting Clearances (mm/inches) LED Side by side .11 3 .11 2.8 .12 3.1 Face to face Facing a metal object Mounting in a metal support e e e .39 10.1 e e: 7/.27 e: 10/.39 e: 30/1.18 e: 40/1.57 e: 7/.27 e: 10/.39 e: 0/0 e: 5/.19 .23 6 XS7 Shielded XS8 Non-shielded Front View Dual Dimensions inches mm 268 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS7/8H Miniature, Inductive Sensor Sub-compact Block Style, DC XS7/8H Miniature, Inductive Sensor / Sub-compact Block Style, DC Specifications Wiring Mechanical 3 wire, N.O. PNP + Standard temperature range BK Enclosure rating - BU + NPN BK BU 0-1.6 mm (0.06") Non-shielded 0-2.4 mm (0.19") Shielded -13 F to +158 F (-25 C to +70 C) Non-shielded +14 F to +122 F (-10 C to +50 C) IEC Type IP67 Shielded 0.08" x 0.08" x 0.04" (2 mm x 2 mm x 1 mm) Vibration resistance Standard target size (steel) BN Shielded 25 G, Amplitude +/- 2 mm, f = 10-55 Hz Non-shielded 0.12" x 0.12" x 0.04" (3 mm x 3 mm x 1 mm) Repeatability (% of Sr) 3% Cable 22 AWG, PvR Electrical - Differential (% of Sr) Maximum 15% Voltage drop (across switch) 2V Current Consumption (no load) 10 mA On and off delay (maximum) .1 ms Power-up delay 5 ms Reverse polarity protection Protective circuitry Standard Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic: transients: impulse IEC 61000-4-2 Level 2: IEC 61000-4-4 Level 4: IEC 60947.5.2 Agency Listings (R) E 164869 CCN NRKH Proximity Sensors BN Usable sensing range CR 44087 Class 3211 03 Note: Refer to page 351 for target material correction coefficient Km. Options Description Suffix 5 meter (16') Cable L1 10 meter (33') Cable L2 269 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS7/8G Inductive Sensors Compact Block Style XS7/8G Inductive Sensors / Compact Block Style Features: * Universal AC/DC and DC only models available * Selectable PNP/NPN, N.O. and N.C. output * Compact 0.47" x 1.02" x 1.57" (12 x 26 x 40 mm) body style, for tight mounting spaces * PLC compatible * Rugged plastic housing * Very high Radio Frequency Immunity * Cable or Nano Style Connector versions offered t * UL Listed, CSA Certified and CE Mark Circuit Type .15 4 Output Mode Voltage Range Max. Voltage Drop Max. Load Current Max. Operating Frequency Max. Catalog Number Universal AC/DC, Shielded - 2 meter (6.6') cable, Nominal Sensing Distance - 2 mm 1.02 26 .70 18 .15 4 2 wire N.O. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c 25 Hz AC/350 Hz DC XS7G12MA230 2 wire N.C. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c 25 Hz AC/350 Hz DC XS7G12MB230 DC, Shielded - 2 meter (6.6') cable, Nominal Sensing Distance - 2 mm 1.57 40 O3.1 45 PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12PA140 NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12NA140 PNP N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 2000 Hz XS7G12PC440 NPN N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 2000 Hz XS7G12NC440 DC, Shielded - Nano Connector, Nominal Sensing Distance - 2 mm t .15 4 (2) .39 10 .47 12 PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12PA140S NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 2000 Hz XS7G12NA140S Universal AC/DC, Non-shielded - 2 meter (6.6') cable, Nominal Sensing Distance - 4 mm 2 wire N.O. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c 25 Hz AC/350 Hz DC XS8G12MA230 2 wire N.C. 20 - 264 Vac/dc 5.5 V 5 to 200 mA c 25 Hz AC/350 Hz DC XS8G12MB230 (3) 1.18 30 DC, Non-shielded - 2 meter (6.6') cable, Nominal Sensing Distance - 4 mm .67 16 PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12PA140 NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12NA140 PNP N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 1000 Hz XS8G12PC440 NPN N.O.+N.C. 10 - 58 Vdc 2.6 V 200 mA 1000 Hz XS8G12NC440 DC, Shielded - Nano Connector, Nominal Sensing Distance - 4 mm t PNP N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12PA140S NPN N.O. 10 - 30 Vdc 1.8 V 100 mA 1000 Hz XS8G12NA140S c t 1.22 31 0.6 Amp fuse is recommended for devices without short circuit protection. See accessories p. 298. See p. 518 for matching connector cables Minimum Mounting Clearances Side by side 1.77 45 Proximity Sensors .26 32 (1) e Face to face e M8 XS*G12*A140S Side view XS7G Shielded XS8G Non-shielded e: 0mm (0") e: 15 mm (.6") e: 10 mm (.4") e: 60 mm (2.4") (1) 1 elongated hole 3.1 x 5.1mm (0.12" x 0.20") (2) Cable, L= 2m (6.6') (3) 2 holes M= 3 x 5mm (0.12" x 0.20") Dual Dimensions inches mm 270 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS7/8G Inductive Sensors Compact Block Style XS7/8G Inductive Sensors / Compact Block Style Specifications Wiring Blue Brown Black 3 BU - BN + BK Output Usable sensing range a + + BN BU 3-wire DC NO XS*G12PA140 XS*G12PA140S 0 - 1.6 mm (.06") Non-shielded 0 - 3.2 mm (.13") Temperature range Enclosure rating 2-wire AC or DC NO or NC XS*G12M*230 Shielded -13 to 158 F (-25 to 70 C) IEC Type Vibration 9conforming to IED 68-2-6) Shock resistance 50 G for 11 ms (conforming to IEC 60068-2-7) Standard target size (steel) 12 x 12 mm (0.47" x 0.47") Differential (% of Sr) 20% Repeatability (% of Sr) 10% LED indicator Located on top of sensor Enclosure material Plastic Wiring 22 AWG (0.34 mm2), PvR cable Electrical + BN/1 Voltage range PNP -10 to 30 Vdc Current consumption (max.)(no load) -- 10 mA Max. Leakage (Residual) Current -open state 0.8 mA at 24 V, 1.5 mA at 120 V 0.1 mA Power-up delay (max.) 40 ms 4 ms On delay (max.) 1 ms 0.5 ms Off delay (max.) + BN/1 Protective Circuitry NPN BK/4 DC models 12 to 24 Vdc 24 to 210 Vdc Voltage limit (including ripple) XS*G12NA140 XS*G12NA140S AC/DC models 24 to 240 Vac 20 to 264 Vac/dc BK/4 BU/3 IP67 (except connector style) 25 G, amplitude =/-2 mm, f = 10 - 55 Hz 2 ms 1 ms Short circuit protection No Yes Overload protection No Agency Listings (R) E 164869 CCN NRKH Proximity Sensors 4 1 Mechanical Cable Connector Yes CR 44087 Class 3211 03 BU/3 Options 4-wire DC NO + NC XS*G12PC440 + BN/1 BK(NO) PNP WH(NC) Description Suffix Extended temperature range to +185 F (+85 C) TT to -40 F (-40 C) TF 5 meter (16') cable length L1 10 meter (33') cable length L2 BU/3 a Refer to p. 351 for target material correction coefficient Km. XS*G12NC440 + BN NPN BK(NO) WH(NC) BU Connector Cables (M8 or S suffix) XSZCS101 Nano Conn., 3 pin, 2 m, straight XSZCS111 Nano Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 271 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XSB Rectangular, Inductive Sensors Compact Block, AC and DC; Plug-in XSB Rectangular, Inductive Sensors / Compact Block, AC and DC; Plug-in Compact long range plug-in inductive proximity sensors for industrial applications. 1.57 40 1.97 50 Features: 1.61 41 * Housings: XSB - Plastic (thermoplastic polyester) * Screw terminals or mini style receptacle 1.57 40 2.99 76 1.97 50 5 5 * Radio Frequency Immunity (RFI) * Noise and transient protection * Reverse polarity protection (DC models) 2 x .16" dia. 2 x 4.2 dia. 1/2" NPT conduit ent. * Selected models are offered with short circuit protection (SCP) and overload protection * UL Listed and CSA Certified. Factory Mutual approved for non incendive applications: NAMUR sensors approved for intrinsically safe applications. CE mark. 25mm (.984") sensing range, Plug-in, Non-shielded Output Mode Dual Dimensions inches mm Voltage Range Max. Load Residual (leakage) Current Operating Frequency Current LED/SCPa Catalog Number NAMUR - DC, 2 wire, screw terminals for use with intrinsically safe relays 1mA/3mA 7-12 V - - 250 Hz No/Yes XSBN25122 1.2 mA 250 Hz No/No XSBC25710 DC models, 2 wire, screw terminals Proximity Sensors N.O. 12-58 V 80 mA AC models, 2 wire, screw terminals N.O. 93-132 V 150 mA 1.7 mA (P) 40 Hz Yes/Yes XSBA25513 N.C. 93-132 V 150 mA 1.7 mA (P) 40 Hz Yes/Yes XSBA25523 N.O. 40-132 V 270 mA 4.5 mA (P) 40 Hz Yes/No XSBA25811 N.C. 40-132 V 270 mA 4.5 mA (P) 40 Hz Yes/No XSBA25821 N.O. 93-264 V 150 mA 4.5 mA (R) 40 Hz Yes/No XSBA25911 N.C. 93-264 V 150 mA 4.5 mA (R) 40 Hz Yes/No XSBA25921 Not for Use on New t c u d ro P d e it im L - s n Applicatio Availability AC models, 2 wire, mini style connector N.O. 93-132 V 150 mA 1.7 mA (P) 40 Hz Yes/Yes XSBA25513R3 N.C. 93-132 V 150 mA 1.7 mA (P) 40 Hz Yes/Yes XSBA25523R3 N.O. 93-264 V 150 mA 4.5 mA (P) 40 Hz Yes/No XSBA25911R3 N.C. 93-264 V 150 mA 4.5 mA (P) 40 Hz Yes/No XSBA25921R3 PLC Applications: P = PLC compatible. R = Bleeder resistor needed for PLC application. a See p. 518 for matching connector cables. For AC devices without SCP, see p. 298 for protective fuses. Minimum Mounting Clearances Side by side Face to face e e XSC.15 e: 38mm (1.5") e: 97mm (3.8") XSC.20 e: 80mm (3.1") e: 160mm (6.3") 272 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XSB Rectangular, Inductive Sensors Compact Block, AC and DC; Plug-in XSB Rectangular, Inductive Sensors / Compact Block, AC and DC; Plug-in Specifications Wiring Mechanical 3 1 Blue Brown Black 2 Usable sensing ranget BU - BN + BK Output NO 4 + - 2 wire AC 3 NO L1 4 L2 1 L1 NC 2 -13 F to +158 F (-25 C to +70 C) * NEMA Type Enclosure rating 3, 4, 6, 13 * IEC Type IP67 Vibration resistance 2 wire DC 1 0-20 mm (.78") Standard temperature range L2 25 G, amplitude 2 mm, f = 10-55 Hz Shock resistance 50 G for 11 ms Standard target size (steel) 3" x 3" (75 x 75 mm) Differential Max. 20% Repeatability Max. 5% Radio Frequency Immunity (RFI) Standard Cable Screw terminals, #16AWG Electrical AC Models Voltage drop (across switch) 9.5 V 7V Inrush current (inductive @ 20mS) .9 A - Minimum load current 20 mA 1.5 mA Power supply current (no load) - 10 mA On delay (max.) 10 ms 0.4 ms DC Models Off delay (max.) 10 ms 1 ms Power-up delay (max.) 150 ms 1.2 ms - Standard Reverse polarity protection Agency Listings (R) E 164353 c CCN NRKH Proximity Sensors Cable Connector LR 44087 a FM: J.I. OROH9.AX Class 3211 03 (3610, 3611) Not for Use on New t c u d ro P d e it im L - s n Applicatio Availability c a Except XSBN25122 Except XSBN25122 LR1599C, Class 3218 06 Options Description Suffix Extended temperature range q to +185 F (+85 C) TT to -40 F (-40 C) TF Ex: XSB C25710 TF q Not available for AC models with SCP. Replacement modules Description Output Mode Voltage Range Leakage Current Catalog Number AC models Base receptacle - - ZSBZ21 Switch body N.O. - 93-132 Vac 1.7 mA ZSBA25513 Switch body N.C. 93-132 Vac 1.7 mA ZSBA25523 Switch body N.O. 93-132 Vac 4.5 mA ZSBA25911 Switch body N.C. 93-132 Vac 4.5 mA ZSBA25921 - - ZSBZ22 12-58 Vac - ZSBC25710 DC models Base receptacle Switch body t N.O. Refer to p. 351 for target material correction coefficient Km. Connector Cables (A or R3 suffix) XSZCA901Y Mini Conn., 3 pin, 2 m, straight XSZCA911Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 273 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Inductive Sensors Cubic Block Style, 26 x 26 mm and 40 x 40 mm Square, DC XS Inductive Sensors / Cubic Block Style, 26 x 26 mm and 40 x 40 mm Square, DC Features * Compact cubed body style in rugged PBT plastic * Flush and Non-flush mountable * Comparable sensing distance to Limit Switch style in half the body size * Mounting bracket included with each sensor 1.02 26 * Molded cable or molded cable with Micro connector pigtail at 0.8 m or 0.15 m length .67 17 1.02 26 LED O3 * Elbow bracket provides interchangeability with Limit Switch style sensor, and enables multiple positioning of sensing face 1.02 26 .98 25 = = Description Nominal Sensing Distance Circuit Type Output Mode Voltage Range Voltage Drop Max. Load Operating Current Frequency Max. Max. Catalog Number 2 wire PNP NPN N.O. N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 12-48 Vdc 5.2 V 2V 2V 100 mA 200 mA 200 mA 100 Hz 1000 Hz 1000 Hz XS7T2DA210 XS7T2PC440 XS7T2NC440 5.2 V 2V 2V 100 mA 200 mA 200 mA 100 Hz 1000 Hz 1000 Hz XS7T2DA214LD XS7T2PC440LD XS7T2NC440LD 26 mm x 26 mm DC, Flush Mountable 2 Meter (6') Cable q O4.2 1.18 30 1.73 44 26 x 26 26 x 26 26 x 26 10 mm 10 mm 10 mm 0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q 26 x 26 26 x 26 26 x 26 1.57 40 1.73 44 1.57 40 = 2.09 53 1.73 44 = N.O. N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 12-48 Vdc 26 x 26 10 mm 2 wire N.O. 12-48 Vdc 5.2 V 100 mA 100 Hz XS7T2DA214LD01 15 mm 15 mm PNP NPN N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 2V 2V 200 mA 200 mA 500 Hz 500 Hz XS8T2PC440 XS8T2NC440 0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q 1.18 30 26 x 26 26 x 26 15 mm 15 mm PNP NPN N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 2V 2V 200 mA 200 mA 500 Hz 500 Hz XS8T2PC440LD XS8T2NC440LD 2 wire PNP NPN N.O. N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 12-48 Vdc 5.2 V 2V 2V 100 mA 200 mA 200 mA 150 Hz 1000 Hz 1000 Hz XS7T4DA210 XS7T4PC440 XS7T4NC440 5.2 V 2V 2V 100 mA 200 mA 200 mA 150 Hz 1000 Hz 1000 Hz XS7T4DA214LD XS7T4PC440LD XS7T4NC440LD 40 mm x 40 mm DC, Flush Mountable 2 Meter (6') Cable q O5.3x8 40 x 40 40 x 40 40 x 40 1.57 40 15 mm 15 mm 15 mm 0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q O5.3x8 40 x 40 40 x 40 40 x 40 1.57 40 = = 1.18 30 40 x 40 2 wire PNP NPN N.O. N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 12-48 Vdc 15 mm 40 x 40 40 x 40 O5.3 2 wire N.O. 12-48 Vdc 5.2 V 100 mA 150 Hz XS7T4DA214LD01 N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc 2V 2V 200 mA 200 mA 1000 Hz 1000 Hz XS8T4PC440 XS8T4NC440 2V 2V 200 mA 200 mA 1000 Hz 1000 Hz XS8T4PC440LD XS8T4NC440LD DC, Non-Flush Mountable 2 Meter (6') Cable q 20 mm 20 mm PNP NPN 0.8 m (2.6 ft) Pigtail with 4 Pin Micro Connector q 40 x 40 40 x 40 q Dual Dimensions inches mm 15 mm 15 mm 15 mm 0.15 m (5.9 ft) Pigtail with 4 Pin Micro Connector q 1.57 2.17 40 55 .98 25 LED 1.22 31 2 wire PNP NPN 0.15 m (5.9 ft) Pigtail with 4 Pin Micro Connector q 26 x 26 26 x 26 O5.3 2.16 55 10 mm 10 mm 10 mm DC, Non-Flush Mountable 2 Meter (6') Cable q .94 24 LED 1.69 43 20 mm 20 mm PNP NPN N.O. + N.C. N.O. + N.C. 12-48 Vdc 12-48 Vdc See p. 518 for matching connector cables Minimum Mounting Clearances XS7T2 Shielded XS7T4 Non-shielded XS7T4 Shielded XS8T4 Non-shielded E1 IN mm E2 IN mm E3 IN mm D1 IN mm H IN mm 0.98 1.57 1.49 2.36 25 40 38 60 4.32 4.71 4.72 6.29 110 120 120 160 1.18 1.77 1.77 2.36 30 45 45 60 1.02 1.57 3.07 4.72 26 40 78 120 0 0 1.02 1.57 0 0 26 40 D1 E1 E2 E3 Side by Side Face to Face Facing a Metal Object H Proximity Sensors 1.57 40 Mounted in a Metal Support 274 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors Cubic Block Style, 26 x 26 mm and 40 x 40 mm Square, DC XS Inductive Sensors / Cubic Block Style, 26 x 26 mm and 40 x 40 mm Square, DC Specifications Wiring Blue Brown Black 2 BU - BN + BK Output 0-8 mm (.32") XS8T2 0-12 mm (.47") -13 to 158 F (-25 to 70 C) NEMA Type 1, 4X, 12 IEC Type IP67 (connector version depends on connector) Vibration BN/1 WH/2 (N.C.) + BK/4 (N.O.) - BU/3 BN/1 + NPN XS7T2 Temperature Range Enclosure Rating 4 Wire PNP Usable Sensing Range a WH/2 (N.C.) BK/4 (N.O.) - BU/3 2 Wire BN/1 +/- 25 G, amplitude =/-2 mm, f = 10-55 Hz Shock Resistance 50 G for 11 ms Differential (% of Sr) 20% Repeatability (% of Sr) 3% LED Indicator Type Yes, located at cable Enclosure Material Plastic Wiring 20 AWG (0.5 mm2), PvR cable Electrical 2 wire 3 wire 4 wire Voltage Range 12-48 Vdc 12-48 Vdc 12-48 Vdc Voltage Limit (Including Ripple) 10-58 Vdc 10-58 Vdc 10-58 Vdc Voltage Drop 5.2 V 2V 5.2 V (max.) Leakage (Residual) Current-Open State 0.7 mA 0.1 mA 0.1 mA Current Consumption 10 mA 10 mA 10 mA Power-up Delay (max.) 5 ms 5 ms 7 ms On Delay (max.) 2 ms 0.3 ms 0.3 ms Off Delay (max.) 5 ms 0.7 ms 0.7 ms Short Circuit Protection Yes Yes Yes Overload Protection Yes Yes Yes Protective Circuitry BU/4 -/+ Agency Listings (R) a E 164869 CCN NRKH Proximity Sensors 3 1 Mechanical Cable Connector 4 CR 44087 Class 3211 03 Refer to p. 351 for target material correction coefficient Km. Mounting options XS7/8T2 M3 x 6 CHC M3 x 6 CHC 90 90 90 90 90 90 XS7/8T4 M3 x 6 CHC 45 90 45 0 M3 x 6 CHC 45 45 90 90 M3 x 6 CHC 0 90 M3 x 6 CHC Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 275 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS7/8C Limit Switch Type, Inductive Sensors 5 Position Turret Head, Plastic AC/DC, DC or AC XS7/8C Limit Switch Type, Inductive Sensors / 5 Position Turrent Head, Plastic AC/DC, DC or AC Sensing head turns to accommodate 5 different sensing positions 1.57 40 1.57 40 Standard limit switch housing inductive proximity sensors for industrial applications. Features: * PBT plastic body with stainless steel screws for corrosive environments. 4.6 117 1.77 45 * Plug-in design for ease in replacement. * 5 position turret head for reduced inventory. * 0.5" NPT conduit entrance with many wiring and connecting options. 2.36 60 * Radio Frequency Immunity (RFI) standard. * PLC compatible. * 2 LED system on selected models indicates ON/OFF, POWER ON. * DC versions work with unfiltered power supply 1.18 30 1.57 40 XS7/8 * Noise and transient protection * Reverse polarity protection (DC models) * Excellent resistance to aggressive environments (dripping corrosive fluids, submersion in water). * Universal AC/DC 2 wire Proximity Sensors * Longest extended range using the standard dimensions 1.57 40 1.57 40 * UL listed, CSA certified and CE mark 1. 1 28 1/2" NPT conduit ent. 2.36 60 4.5 114.5 1.77 45 Circuit Type Output Mode Voltage Range AC DC Maximum Load Current c Residual (leakage) current Operating Frequency LED/SCPa Catalog Number 0.5 mA at 24 V 25/50 Hz 1.5 mA at 120 V Yes/No XS7C40MP230 100 mA 100 mA 200 mA 200 mA 0.5 mA 0.5 mA - 1500 Hz 1500 Hz 1000 Hz 1000 Hz Yes/Yes Yes/Yes 2/Yes 2/Yes XS7C40DA210 XS7C40DP210 XS7C40PC440 XS7C40NC440 200 mA 200 mA - 1000 Hz 1000 Hz 2/Yes 2/Yes XS7C40PC449 XS7C40NC449 500 mA 1.5 mA 25 Hz Yes/No XS7C40FP260 0.5 mA at 24 V 25/50 Hz 1.5 mA at 120 V Yes/No XS8C40MP230 100 mA 100 mA 200 mA 200 mA 0.6mA 0.6mA - 150 Hz 150 Hz 1000 Hz 1000 Hz Yes/No Yes/No 2/Yes 2/Yes XS8C40DA210 XS8C40DP210 XS8C40PC440 XS8C40NC440 200 mA 200 mA - 500 Hz 500 Hz 2/Yes 2/Yes XS8C40PC449 XS8C40NC449 500 mA 1.5 mA 25 Hz Yes/No XS8C40FP260 13 Hz Yes/No XSCT023319 Shielded 15mm (.59") sensing range universal, AC/DC LED 2 wire N.O./N.C. 24-240 V 24-210 V 300 mA/200 mA 15mm (.59") sensing range, DC 2 x .2" dia. 2 x 5.3mm dia. 1.18 30 XSCT 2 wire 2 wire PNP NPN N.O. N.O./N.C. N.O. + N.C. N.O. + N.C. - 12-48 V 12-48 V 12-48 V 12-48 V 20mm (.79") extended range, DC 3 wire PNP NPN N.O. + N.C. N.O. + N.C. - 12-48 V 12-48 V 15mm (.59") sensing range, AC 2 wire Dual Dimensions inches mm N.O./N.C. 24-240 V - Non-shielded 20mm (.79") sensing range universal, AC/DC 2 wire N.O./N.C. 24-240 V 24-210 V 300 mA/200 mA 20mm (.79") sensing range, DC 2 wire 2 wire PNP NPN N.O. N.O./N.C. N.O. + N.C. N.O. + N.C. - 12-48 V 12-48 V 12-48 V 12-48 V 40mm (1.6") extended range, DC 3 wire PNP NPN N.O. + N.C. N.O. + N.C. - 12-48 V 12-48 V 20mm (.79") sensing range, AC 2 wire N.O./N.C. 24-240 V - 20mm (.79") sensing range, AC Model with Timer (1-20s) 2 wire N.O./N.C. 24-240 V - 350 mA 2.0 mA (R) For devices without SCP, an 0.8A quick blow fuse wired in series is recommended, see p. 298 for protective fuses. 20 Vdc 58 IEC 60947-5-2 Utilization category DC-13: Vdc > IEC 60947-5-2 Utilization category DC-12 a c Minimum Mounting Clearances (mm/inches) Face to Face Side by side e t e t XS7 Shielded XS8 Non-shielded e: 40/1.57 e: 80/3.15 e: 120/4.72 e: 160/6.30 276 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS7/8C Limit Switch Type, Inductive Sensors 5 Position Turret Head, Plastic AC/DC, DC or AC XS7/8C Limit Switch Type, Inductive Sensors / 5 Position Turrent Head, Plastic AC/DC. DC or AC Specifications Wiring Mechanical 1 3 2 1 3 K30/K31 Cable Blue Brown Black 2 R30/R31 3 4 2 5 1 R5 2 wire DC Non Polarized 5 +/-/+ 6 NO NC 4 wire DC NO/NC PNP 1 + 4 (NO) 2 (NC) - 3 NPN 1 + NPN 4 (NO) 2 (NC) 3 Non-shielded Standard temperature range Enclosure rating Enclosure material BU - BN + BK Output PNP Shielded Usable sensing range t - NEMA Type 0-16 (63") -13 F to +158 F (-25 C to +70 C) 4, 6P, 12 (UL test pending) CENELEC Type IP67 Body & sensing face PBT Screws Stainless Steel Vibration resistance IEC 60068.2.6 25 G, amplitude at 55 Hz, f = 10-55 Hz Shock resistance IEC 60068.2.27 50 G duration 11 ms Standard target size (steel) Shielded 45 x 45 mm (1.8" x 1.8") Non-shielded 60 x 60 mm (2.4" x 2.4") Differential Max. 20% Repeatability Max. 3% Radio Frequency Immunity (RFI) Standard Cable Screw terminals Electrical AC Models Voltage range DC Models AC/DC Models 2 wire 4 wire 24-240 V 50/60 Hz 12-48 V 12-48 V 24-240 Vac 50/60 Hz 24-210 Vdc Voltage limit (including ripple) 20-264 V 50/60 Hz 10-58 V 10-58 V 20-264 Vac/dc Voltage drop (across switch) closed state 5.5 V 4V 2V 5.5 V Minimum load current 5 mA 1.5 mA - 5 mA Maximum load current 500 mA 100 mA 100 mA 300 mA/200 mA Inrush 2Aa - - 2 Aa Current consumption (no load) - - 10 mA - On delay (max.) 30 ms 2 ms 0.3 ms 30 ms 20 ms 5 ms 0.7 ms 20 ms 20 ms 7 ms 0.7 ms 20 ms 120 ms 5 ms 5 ms 120 ms Shielded Off delay (max.) Non-shielded Power-up delay (max.) 2 wire AC 0-12 mm (.47") Proximity Sensors Connector Protective circuitry 5 6 NO/NC Selector Jumper NO Short circuit protection Optional a Overload protection Yes Radio frequency immunity (RFI) IEC 61000-4-3 Level 3 Electrostatic; Transients; Impulse IEC 61000-4-2 Level 4; IEC 61000-4-3 Level 3; IEC 60947.5.2 Level 3 Reverse polarity protection DC Versions Yes Agency Listings (R) NC t a E 164869 CCN NRKH CR 44087 Class 3211 03 See page 351 for target material corrective coefficient km. Without overload or SCP, an 0.8 A quick blow fuse wired in series is recommended, see page 298 for protective fuses. Options Description Suffix Extended temperature range +185 F (+85 C) Extended temperature range -40 F (-40 C) TF 3 pin mini style connector Normally open R30 3 pin mini style connector Normally closed 5 pin mini style connector TT R31 R5 3 pin micro stye connector AC only, wired Normally open K30 3 pin micro style connector AC only, wired Normally closed K31 Connector Cables (R3, R5 or K suffix) XSZCK101Y Micro Conn., 3 pin, 2 m, straight XSZCK111Y Micro Conn., 3 pin, 2 m, 90 XSZCA901Y Mini Conn., 3 pin, 2 m, straight XSZCA911Y Mini Conn., 3 pin, 2 m, 90 XSZCA1501Y Mini Conn., 5 pin, 2 m, straight XSZCA1511Y Mini Conn., 5 pin, 2 m, 90 For additional cable options and lengths see p. 518 277 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Inductive Sensors Limit Switch Body, 5 Position Turret Head, DC IQ ProxTM XS Inductive Sensors / Limit Switch Body, 5 Position Turrent Head, DC IQ Prox 1.57 40 1.57 40 4.6 117 1.77 45 2.36 60 * Can be recessed mounted in metal without interference with sensing field * Long range sensing 0.98" (25 mm) (4) (2) Features: Microprocessor based, self-teaching Proximity Switch adjusts to its environment on command, suppressing any metal background, then detecting the target it was taught to identify. (See Illustration). (1) * Plastic Limit Switch plug-in body style with 5 position turret head (3) * Two LEDs: (1) power supply and terminal mode (flashes in learning mode when sensor is learning its environment), (2) output 1.18 30 1.57 40 (1) Output LED (Yellow) (2) Power/Teach LED (Green) (3) 1/2" NPT conduit opening (4) Two elongated mounting holes: 0.21" x 0.28" (5.3 mm x 7 mm) Proximity Sensors Dual Dimensions inches mm * 24 Vdc, complementary PNP and NPN type output * UL Listed, CSA Certified, CE Mark Illustrations: 1. Sensor can be flush mounted, non-flush mounted or recessed mounted. A metal background can be placed in immediate proximity of the sensor. GN 2. To set up, activate "teach" mode. When no target is present, sensor will learn the environment. Then, pass target in front of the sensor in the usual way. YW GN YW 4. The newly programmed sensor will recognize the target and provide output. 3. Green LED flashes when sensor is learning its environment and target, then becomes steady when sensor is set. Sensing Distance Circuit Type Output Mode Connection Catalog Number 25 mm 25 mm PNP NPN N.O. N.O. Screw Terminal Screw Terminal XS8C40PAA40 XS8C40NAA40 Minimum Mounting Clearances (mm/inches) Side by side Face to face e e XSC8C40*AA40 e: 80/3.15 e: 9.45m/240 278 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors Limit Switch Body, 5 Position Turret Head, DC IQ ProxTM XS Inductive Sensors / Limit Switch Body, 5 Position Turrent Head, DC IQ Prox Specifications Wiring Mechanical Temperature Range 3-wire DC, NO output Enclosure Rating 1 BN PNP + 4 BK BU - 3 1 Operating Storage -13 F to 158 F (-25 C to 70 C) -13 F to 158 F (-25 C to 70 C) NEMA Type 4, 4X, 6, 6P, 12, IEC Type IEC IP67 per IEC 60529 Enclosure Material Case PBT Vibration resistance (IEC 60068-2-6) 25 G, amplitude at 55 Hz, f = 10 - 55 Hz Shock resistance (IEC 60068-2-27) 50 G, duration 11 ms Differential (max.) (% of Sr.) 15% Repeatability (max.) (% of Sr.) 3% Power/Teach (green) LED indicator type BN BK + 4 Output (yellow) Connection Screw Terminal Electrical BU - 3 XS8C40kAA40 Voltage Limit (including ripple) 19 - 30 Vdc Voltage Drop (across switch) closed state (max.) 2V Current consumption (no load) (max.) 20 mA Load Current (max.) 200 mA Operating frequency (max.) 600 Hz On delay (max.) 1 ms Off delay (max.) 1 ms Power-up delay (max.) 250 ms Short circuit protection Yes Overload protection Yes Reverse polarity protection Proximity Sensors NPN Yes Agency Listings (R) E 164869 CCN NRKH CR 44087 Class 3211 03 Activating self-teaching mode Option 1 by external contact + 1 2 3 Option 2 internally (repositioning of jumper) External contact (pulse) or - When in the self-teaching mode, the green LED (status) flashes rapidly. As objects pass through the detection zone, the sensor memorizes the two opposing thresholds in relation to its environment. When the self-teaching is complete, the green LED ceases to flash and maintains a steady light. The yellow LED indicates output. 279 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XSD Rectangular, Inductive Sensors Long Range Block, AC and DC - Plug-in XSD Rectangular, Inductive Sensors / Long Range Block, AC and C - Plug-in Features Rectangular low profile switch 3.5" square by 1.63" high ( 88.4 x 41.4 mm) designed for very demanding industrial applications. Shielded 1.5 40 .33 8.5 3.23 82 * Housings: Plastic (thermoplastic polyester) 3.98 101 2.56 65 * LED indicators: target sensed, power on and short circuit (selected models) * Timer model available for jamming applications * Plug-in modular design * Radio Frequency Immunity (RFI) 2.96 75 4 x dia. .21" 4 x dia. 5.5 mm * Short circuit protection (SCP) (selected models) * Alternate frequency models for side by side mounting (selected models) * DC models: complementary outputs (PNP or NPN) Unshielded * AC models: selectable normally open (N.O.) or normally closed (N.C.) 1.5 40 * UL Listed, CSA Certified and CE marked 3.90 100 Proximity Sensors 2.56 65 .29 7.5 3.10 80 40 mm (1.57") Sensing Range, Shielded Circuit Type 4 x dia. .21" 4 x dia. 5.5 mm LED Voltage Range q Max. Load Residual (Leakage) Current Operating Frequency Maximum LED/SCPa Catalog Number 100 mA 0.5 mA 180 Hz Yes XSDC407138 DC Model, Screw Terminals 2 wire 2.56 65 1/2" NPT conduit ent. Output Mode N.O. 12-48 V 40 mm (1.57") Sensing Range, Non-shielded DC Model, Screw Terminals 2 wire PNP NPN N.O. N.O. + N.C. N.O. + N.C. 12-48 V 12-48 V 12-48 V 100 mA 200 mA 200 mA 0.5 mA - - 180 Hz 50 Hz 50 Hz Yes/Yes Yes/Yes Yes/Yes XSDC407139 XSDH407339j XSDJ407339j 500 mA 500 mA 1.5 mA (P) c 1.5 mA (P) c 10 Hz 10 Hz Yes/No 3f/Yes XSDA400519j XSDA405539j AC Model, Screw Terminals 2 wire 2 wire N.O.,N.C. N.O.,N.C. 24-240 V 24-240 V AC Model Mini Style Connector, 3 Pins l Dual Dimensions inches mm 2 wire 2 wire N.O.,N.C. N.O.,N.C. 24-240 V 24-240 V 500 mA 500 mA 1.5 mA (P) c 1.5 mA (P) c 10 Hz 10 Hz Yes/No 3f/Yes XSDA400519R3j XSDA405539R3j 24-240 V 500 mA 3.5 mA (R) c 10 Hz Yes/No XSDT023319 5-100 mA DC 1.7mA at 120V 10 Hz 5-500 mA AC 3 mA at 240V k 3f/Yes XSDM500538 AC Model with Timer 2 wire N.O.,N.C. 50 mm (2") Sensing Range, Shielded AC/DC Model, Screw Terminals 2 wire N.O./N.C. 24-240 V 50 mm (2") Sensing Range, Non-shielded DC Model, Screw Terminals 2 wire N.O. 12-48 V 100 mA 0.5 mA 180 Hz Yes/Yes XSDC507139 500 mA 500 mA 1.5 mA 1.5 mA 10 Hz 10 Hz Yes/No 3f/Yes XSDA500519 XSDA505539 Yes/No 3f/Yes XSDA500519Rj XSDA505539Rj AC Model, Screw Terminals 2 wire 2 wire N.O./N.C. N.O./N.C. 24-240 V 24-240 V AC Model Mini Style Connector, 3 Pins l 2 wire N.O/.N.C. 24-240 V 500 mA 1.5 mA 10 Hz 2 wire N.O./N.C. 24-240 V 500 mA 1.5 mA 10 Hz k 100 mA for DC. c PLC applications: P= PLC compatible. R= Bleeder resistor needed. j Also available with alternate frequency. Add F to catalog number. No additional charge. f 1 LED for power ON, 1 LED for output ON, 1 LED for SCP triggered. l Mating connector see p. 518. a For devices without SCP, see p. 298 for protective fuses. Minimum Mounting Clearances (Except XSDM500538) (mm/inches) Side by side Face to face e e XSD 40 XSD 50 e: 200/7.9 e: 250/10 e: 400/15.7 e: 500/20 280 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XSD Rectangular, Inductive Sensors Long Range Block, AC and DC - Plug-in XSD Rectangular, Inductive Sensors / Long Range Block, AC and DC - Plug-in Specifications Wiring Blue Brown Black 2 3 wire DC, NO/NC BU - BN + BK Output + 1 24-48 mm (0.94" - 1.89") Standard Temperature Range -13 F to +158 F (-25 C to +70 C) Enclosure Rating NEMA Type 3,4 X (indoor),12,13 IEC Type IP67 Vibration Resistance 25 G, amplitude 2 mm, f =10-55 Hz 4 (NO) Shock Resistance 50 G for 11 ms 2 (NC) Standard Target Size (Mild Steel) 120 x 120 mm (4.7" x 4.7") + 3 1 NPN 4 (NO) 2 (NC) 3 Usable Sensing Rangea - 2 wire DC, non polarized 3 NO 4 3 +/-/+ +/- NC 4 -/+ Differential Maximum 20% Repeatability Maximum 5% Cable, PVC Screw Maximum, #16 AWG Electrical AC Models Voltage range max. (including ripple) 20-264 V 10-58 V 10-58 V 20-264 V Voltage Drop (Across Switch) 5.5 Va 4V 1.8 V 6V load NO 2A - - 2A 5 mA 1.5 mA - 5 mA Current consumption (No Load) - - 10 mA - On Delay (max.) 30 ms 0.2 ms 10 ms 40 ms Off Delay (max.) 20 ms 3 ms 10 ms 60 ms Power-up Delay (max.) 120 ms 5 ms 10 ms 100 ms Reverse Polarity Protection - Standard Standard - Radio Frequency Immunity (RFI) 4 cm (1.6") Minimum from antenna a L1 8 7 E 164353 c CCN NRKH LR 44087 a Class 3211 03 L2 FM: J.I. OROH9.AX (3610, 3611) Timer model voltage drop is 4.5 V. Options Description NC AC/DC Models 4 wire Minimum Load Current (R) 8 7 2 wire Inrush Current (Inductive @ 20mS) Agency Listings 2 wire AC and AC/DC, programmable NO/NC DC Models Proximity Sensors 3 PNP Mechanical Cable Connector 1 Extended Temperature Rangea Suffix to +185 F (85 C) (p Not Available on AC Models with SCP) TT to -40 F (-40 C) TF Ex: XSD605539 TTR3 Replacement Modules Description Catalog Number DC 2 Wire Base Receptacle, N.O. Contact ZSDZ03 N.O. Contact Switch ZSDC607139 Base Receptacle, N.O./N.C. ZSDZ02 N.O./N.C. Contact Switch ZSDC607319 DC 3 Wire Base Receptacle ZSDZ02 PNP Switch ZSDH607339 NPN Switch ZSDJ607339 AC 2 Wire Base Receptacle ZSDZ01 1 LED, N.O. SCP Switch ZSDA600519 3 LED, SCP Switch ZSDA605539 AC/DC ZSDM600539 p Refer to p. 351 for target material correction coefficient Km. Connector Cables (A or R3 suffix) XSZCA901Y Mini Conn., 3 pin, 2 m, straight XSZCA911Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 281 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XSD Rectangular, Inductive Sensors Long Range Block, AC and DC; Adjustable Sensing Range XSD Rectangular, Inductive Sensors / Long Range Block, AC and DC; Adjustable Sensing Range 1.5 40 3.90 100 2.56 65 .29 7.5 3.10 80 4 x dia. .21" 4 x dia. 5.5 mm LED 2.56 65 1/2" NPT conduit ent. Features: Rectangular low profile switch 3.5" square by 1.63" high ( 88.4 x 41.4 mm) designed for very demanding industrial applications. Especially recommended for long sensing range applications with metal in the background. * Housings: Plastic (thermoplastic polyester) * Adjustable sensing range (30 to 60mm); sensitivity can be decreased below the maximum usable sensing distance (48mm) to cancel the metal background influence (20 turn potentiometer under the front plastic cap). For fixed long sensing distance, see page 280. * LED indicators: target sensed, power on and short circuit (selected models) * Plug-in modular design * AC/DC model available * Radio Frequency Immunity (RFI) * Short Circuit Protection (SCP) (selected models) * 1/2" NPT conduit entrance * Protected, captive saddle clamp terminals in ready-to-wire position * DC models: complementary outputs PNP or NPN Proximity Sensors Dual Dimensions inches mm * AC models: programmable output N.O./N.C. * UL Listed and CSA Certified NOTE: Sensors are delivered and adjusted from the factory for maximum sensing distance. Do not attempt to increase the sensing distance above the factory setting; sensor behavior becomes unpredictable. 30-60 mm (2.36") sensing range, Non-shielded Circuit Type Output Mode Voltage Range Max. Load Residual (leakage) Current Max Operating Frequency Maximum LED/SCPa Catalog Number DC model, 2 and 3 wire screw terminals 2 wire N.O. 12-48 V 100 mA 0.8 mA 20 Hz Yes/Yes XSDC607139 2 wire N.O.,N.C. 12-48 V 100 mA 0.8 mA 20 Hz Yes/No XSDC607319 PNP N.O.,N.C. 12-48 V 200 mA - 50 Hz Yes/Yes XSDH607339 NPN N.O.,N.C. 12-48 V 200 mA - 50 Hz Yes/Yes XSDJ607339 AC model, screw terminals 2 wire N.O./N.C. 24-240 V 500 mA 1.7 mA 10 Hz Yes/No XSDA600519 2 wire N.O./N.C. 43-132 V 500 mA 1.7 mA 10 Hz 3/Yes XSDA605539 24-240 Vac 500 mA 1.7 mA @ 120 V c 24-210 Vdc 100 mA 115 V 10 Hz 3/Yes XSDM600539 AC and DC models, screw terminals 2 wire N.O./N.C. AC and AC/DC models, mini style receptacle, 3 pins 2 wire N.O./N.C. 24-240 V 500 mA 1.7 mA 10 Hz Yes/No XSDA600519R3 2 wire N.O./N.C. 93-132 V 500 mA 1.7 mA 10 Hz 3/Yes XSDA605539R3 2 wire N.O./N.C. 10 Hz 3/Yes XSDM600539R3 24-240 Vac 500 mA 1.7 mA 24-210 Vdc 100 mA 1.7 mA @ 120 V c PLC compatible. c a 1 LED for power OUT and 1 LED for output ON, 1 LED for SCP triggered. < 1 mA @ 24 V, < 3 mA @ 240 V For devices without SCP, see p. 298 for protective fuses. Minimum Mounting Clearances (mm/inches) Side by side Face to face e e XSD30-60 e: 300/12 e: not recommended 282 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XSD Rectangular, Inductive Sensors Long Range Block, AC and DC; Adjustable Sensing Range XSD Rectangular, Inductive Sensors / Long Range Block, AC and DC; Adjustable Sensing Range Specifications Wiring Blue Brown Black 2 3 wire DC, NO/NC BU - BN + BK Output + 1 Usable sensing range a 24-48 mm (0.94" - 1.89") Standard temperature range -13 F to +158 F (-25 C to +70 C) Enclosure rating NEMA Type IEC Type Vibration resistance 3, 4, 6, 12, 13 IP67 25 G, amplitude 2 mm, f = 10-55 Hz 4 (NO) Shock resistance 50 G for 11 ms 2 (NC) Standard target size (mild steel) 120 x 120mm (4.7" x 4.7") Differential Max. 20% + 3 1 NPN Repeatability Max. 5% Cable, PVC Screw terminals, #16 AWG Electrical AC Models Voltage range (including ripple) Voltage drop (across switch) DC Models 4 (NO) 2 (NC) 3 2 wire DC, non polarized 3 NO 4 3 +/-/+ +/- NC 4 4 wire AC/DC Models 10-58 V 10-58 V 20-264 V 7V 1.8 V 6V - - - 2A 5 mA - 1.5 V - 5 mA Current consumption (no load) - 10 mA - 10 mA - On delay (max.) 30 ms 5 ms 5 ms 10 ms 40 ms Off delay (max.) 20 ms 40 ms 25 ms 10 ms 60 ms Power-up delay (max.) 120 ms 75 ms 30 ms 10 ms 100 ms Reverse polarity protection - Standard Standard Standard - Radio Frequency Immunity (RFI) 4 cm (1.6") Minimum from antenna 2 wire, N.O. 2 wire, N.O./N.C. 20-264 V 10-58 V 4.5 V 4V Inrush current (inductive @ 20mS) 2A Minimum load current - -/+ Agency Listings 2 wire AC, programmable NO/NC L1 8 7 load NO 8 7 (R) E 164353 c CCN NRKH LR 44087 a Class 3211 03 L2 FM: J.I. OROH9.AX (3610, 3611) Options Description NC Proximity Sensors 3 PNP Mechanical Cable Connector 1 Extended temperature rangea Suffix to +185 F (85 C) (a Not available on AC models with SCP) TT to -40 F (-40 C) TF Ex: XSD605539 TTR3 Replacement modules Description Catalog Number DC 2 wire Base receptacle, N.O. contact ZSDZ03 N.O. contact switch ZSDC607139 Base receptacle, N.O./N.C. ZSDZ02 N.O./N.C. contact switch ZSDC607319 DC 3 wire Base receptacle ZSDZ02 PNP switch ZSDH607339 NPN switch ZSDJ607339 AC 2 wire Base receptacle ZSDZ01 1 LED, N.O. SCP switch ZSDA600519 3 LED, SCP switch ZSDA605539 AC/DC ZSDM600539 a Refer to page 351 for target material correction coefficient Km. Connector Cables (A or R3 suffix) XSZCA901Y Mini Conn., 3 pin, 2 m, straight XSZCA911Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 283 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XSAV Tubular, Inductive Sensors 30mm Diameter, Motion Detection, DC or AC/DC XSAV Tubular, Inductive Sensors / 30 mm Diameter, Motion Detection, DC or AC/DC 2.24 57 M 30 x 1.5 The XSAV is a self-contained device used to detect and send output alarms for machinery under speed or zero-speed conditions, as well as early jamming detection. The early detection of the under speed condition is useful in reducing downtime due to jamming or transmission failure. especially in the cases of medium and large motors. The zero speed condition is used extensively for safety interlocking applications, including: conveyors, pumps, mixers, centrifugal separators, elevators, saws, and crushers. .94 24 Adjustment potentiometer Dual Dimensions inches mm As long as the speed (number of pulses/min.) is above the threshold level - adjustable via 25 turn potentiometer within the threshold range - the output circuit assumes its closed state. When the actual speed falls below the threshold level - the output circuit assumes its open state. To preserve the start up delay, the switch should be reset by removing and reapplying the power supply. When the line voltage is initially applied, the output automatically assumes its closed state for the duration of the start-up delay. This allows the mechanical assembly to overcome inertia and reach its nominal speed, greatly simplifying the interlocking circuit. After the start-up delay, the switch will perform as described above. Care should be taken not to exceed the maximum frequency rating above which the sensor cannot detect the target and therefore assumes "zero speed" condition. Proximity Sensors Features: * Universal AC/DC versions * AC/DC models are PLC compatible * Linear speed threshold adjustment * Two adjustment ranges: 6 - 150 pulses/min. for zero-speed, 120 - 3,000 pulses/min. for jamming detection * Built-in fixed power-up delay to overcome start-up inertia * Radio frequency immunity (RFI) * Reverse polarity protection on DC models * Noise and transient protection * Overload and short circuit protection (SCP) on DC models * LED indicators for switch in "closed" state * 25-turn potentiometer provides fine adjustment of the under speed threshold Circuit Type Max. Load Residual (Leakage) Threshold Range (Pulse/Min.) Max. Frequency (Pulse/Min.) Start-up Delay LED/SCP q Catalog Number 30mm Diameter, 10mm sensing range, Shielded, 2m cable DC models, 10-58 Vdc (including ripple) PNP PNP PNP PNP 200 mA 200 mA 200 mA 200 mA 0 0 0 0 6-150 6-150 120-3000 120-3000 6000 6000 48000 48000 9 sec. 3 sec. 9 sec. 3 sec. Yes/Yes Yes/Yes Yes/Yes Yes/Yes XSAV11373 XSAV31373 XSAV12373 XSAV32373 6-150 6-150 120-3000 120-3000 6000 6000 48000 48000 9 sec. 0 sec. 9 sec. 0 sec. Yes/No Yes/No Yes/No Yes/No XSAV11801 XSAV01801 XSAV12801 XSAV02801 AC/DC models, 20-264 Vac/dc 2 wires 2 wires 2 wires 2 wires a q 0.35 A Vac/0.2 A Vdc 0.35 A Vac/0.2 A Vdc 0.35 A Vac/0.2 A D Vdc 0.35 A Vac/0.2 A Vdc 1.5 mA (P)a 1.5 mA (P)a 1.5 mA (P)a 1.5 mA (P)a (P) - PLC Compatible, (R) - Bleeder resistor required for PLC applications For devices without SCP, see p. 298 for protective fuses. Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e 30 mm e: 20/.79 e e: 120/4.7 e: 30/1.2 D: 30/1.2, H: 0/0 284 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XSAV Tubular, Inductive Sensors 30mm Diameter, Motion Detection, DC or AC/DC XSAV Tubular, Inductive Sensors / 30 mm Diameter, Motion Detection, DC or AC/DC Specifications Wiring Mechanical Bn PNP Usable sensing rangea + 0-0.15" (0-4 mm) 1.18" (30 mm) 0--.31" (0-8 mm) Standard temperature range Bk Enclosure rating - Bu 0.7" (18 mm) -13 F to +158 C (-25 F to +70 F) NEMA Type 1, 3, 4, 6, 12, 13 IEC Type IP67 Vibration resistance 25 G, amplitude 2 mm, f =10-55 Hz Shock resistance 2 wire, AC/DC Bn Bu Standard target size (steel) +/+/- 50 G duration 11 ms 0.7" (18mm) diameter 0.7" x 0.7" (18mm x 18mm) 1.18" (30mm) diameter 1.18" x 1.18" (30mm x 30mm) Repeatability (% of Sr) 3% Differential (hysteresis) Cable 5-15% of pre-set frequency PvR 20 AWG Electrical AC/DC Voltage drop (across switch) max. 5.7 V DC 1.8 Vdc Inrush current (inductive @ 20 ms) 2A - Minimum load current 5 mA - Current Consumption (no load) - 15 mA XSAV1 models Start-up delay (max.) 9 sec. 20% + 1/Fr XSAV3 models 3 sec. 20% + 1/Fr XSAV0 models 0 sec. Agency Listings a 1/Fr in the start up delay formula is the actual preset frequency adjusted via potentiometer. (1/Fr is not significant if threshold is above 60 pulses/min.). Refer to page 351 for target material correction coefficient Km. Options Description Suffix Extended temperature range (only one option per device) 7427 to +185 F (+85 C) TT to -40 F (-40 C) TF 5 meter cable length L05 10 meter cable length L10 Ex: XSAV11373 TT L05 Accessories 9006PA30 XSZB130 Description Catalog Number Metal locknuts (1 pair included) XSZE130 Mounting bracket, 90 steel 9006PA30 Mounting bracket, plastic XSZB130 0.5" NPT conduit adapter 7427 Application Notes: 25 turn Potentiometer Cover The number of targets is determined knowing that the actual number of pulses per minute n, is n=mN where m is the number of targets and N the speed in rpm. This number (n) should be within the operating frequency range given in the selection table. For reasons of mechanical balance, even numbers are recommended (2, 4, 6 etc.). Frequency threshold adjustment: As long as the speed (number of pulses/min.) is above the threshold level - adjustable via 25 turn potentiometer within the threshold range - the output circuit assumes its closed state. When the actual speed falls below the threshold level, the output circuit assumes its open state. To preserve the start-up delay, the switch should be reset by removing and reapplying the power supply. When the line voltage is initially applied, the output automatically assumes its closed state for the duration of the start-up delay. This allows the mechanical assembly to overcome inertia and reach its nominal speed, greatly simplifying the interlocking circuit. After the start-up delay, the switch will perform as described above. Care should be taken not to exceed the maximum frequency rating above which the sensor cannot detect the target, therefore, assuming zero speed condition. Accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298 285 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors 3 wire, DC Proximity Sensors XS Tubular Inductive Sensors Weld Field Immune, DC XS Tubular Inductive Sensors / Weld Field Immune, DC Features Industrial welding processes create fields of electromagnetic "noise" which can interfere with the magnetic fields of inductive proximity sensors. Standard proximity sensors can be falsely triggered when near to these fields. WFI sensors allow uninterrupted performance when placed extremely close to the conductor carrying the welding current. LED LED XS1M12 * The body styles are cylindrical in 0.47", 0.7" and 1.18" (12, 18 and 30 mm) diameters. * Enclosure material is brass coated in Teflon(R) to prevent slag (molten bits of metal) from sticking to sensing face, reducing the possibility of false triggering. XS2M12 * Available in Micro connector versions.a * Mounting nuts included. Circuit Type Output Mode Voltage Range Voltage Drop Maximum Load Current Maximum Operating Frequency Maximum Catalog Number 12 mm Shielded, DC with Micro Connector a, Nominal Sensing Distance-2 mm PNP LED LED XS1M18 N.O. 10 to 36 Vdc 2.5 V 250 mA 1000 Hz XS1M12PAW01D 12 mm Non-shielded, DC with Micro Connector a, Nominal Sensing Distance-4 mm XS1M30 PNP N.O. 10 to 36 Vdc 2.5 V 250 mA 1000 Hz XS2M12PAW01D 18 mm Shielded, DC with Micro Connector a, Nominal Sensing Distance-5 mm PNP N.O. 10 to 36 Vdc 2.5 V 250 mA 500 Hz XS1M18PAW01D Proximity Sensors 30 mm Shielded, DC with Micro Connector a, Nominal Sensing Distance-10 mm Dimensions PNP a = Overall Length (mm) b = Threaded Section (mm) c = for Non-shielded Sensors (mm) b c a N.O. 10 to 36 Vdc 2.5 V 250 mA 250 Hz XS1M30PAW01D See p. 518 for matching connector cables. The formula below shows the relationship between distance (r [mm]) and electromagnetic flux density (B[MT]). B [mT] = 0.2xI [A] B [mT] = Electromagnetic Flux Density r [mm] I[A] = Welding Current r [mm] = Distance a Minimum Mounting Clearances a b c XS1M12 2.3" (60) 1.6" (40) 0 XS2M12 2.3" (60) 1.5" (38) 0.16" (4) XS1M18 2.3" (60) 1.6" (40) 0 XS1M30 2.3" (60) 1.6" (40) 0 Face to face Side by side Facing a metal object Mounting in a metal support D H e e e Side by Side Face to Face Facing a Metal Object Mounted in Metal e e e d IN mm IN 0.27 mm XS1M12 0 0 7 XS2M12 0.59 15 0.27 XS1M18 0 0 0.63 XS1M30 0 0 0.79 20 IN mm 0.24 6 7 0.43 11 16 0.35 9 0.79 20 IN 0.47 1.42 0.71 1.18 h mm IN 12 0 mm 0 36 0.31 8 18 0 0 30 0 0 286 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Tubular Inductive Sensors Weld Field Immune, DC XS Tubular Inductive Sensors / Weld Field Immune, DC Specifications Wiring BN/1 + PNP BK/4 N.O. BU/3 1 XS1M12 XS2M12 XS1M18 XS1M30 Usable Sensing Range a 1.6 mm 3.2 mm 4 mm 8 mm 35 N*m 26 (lb-ft) 50 N*m 37 (lb-ft) Temperature Range Enclosure Rating - 2 Mechanical 3 4 13 F to +158 F (-25 C to +70 C) NEMA Type 3, 4, 6, 12, 13, 4X Indoor IEC Type IP67 (or depending on connector) Tightening torque (max.) 15 N*m 11.1 (lb-ft) Vibration 25 G Amplitude +/-2 mm f = 10-55 Hz Shock Resistance 50 G for 11 ms Differential (% of Sr) 20% 15 N*m 11.1 (lb-ft) Repeatability (% of Sr) 3% LED Indicator Type 4 LED windows at 90 degrees Enclosure Material Brass with Teflon coating Electrical Voltage Range 12 to 24 Vdc Voltage Limit (Including Ripple) 10 to 36 Vdc Current Consumption (max.) (No Load) 15 mA max. Leakage (Residual) Current-Open State - Power-up Delay (max.) 10 ms 10 ms 10 ms 10 ms On Delay (Maximum) 0.1 ms 0.2 ms 0.2 ms 0.7 ms Off Delay (max.) 0.4 ms 0.4 ms 0.6 ms 5 ms Protective Circuitry Overload Protection Yes Reverse Polarity Protection Yes Agency Listings (R) a Yes E 164869 CCN NRKH Proximity Sensors Short Circuit Protection LR 702985 Class 3211 03 Refer to page 351 for target material correction coefficient Km. Accessories Description Mounting Brackets Mounting Nuts For Sensor Diameter Catalog Number 0.47" (12 mm) XSZB112 0.47" (12 mm) 9006PA12 0.7" (18 mm) XSZB118 0.7" (18 mm) 9006PA18 1.18" (30 mm) XSZB130 1.18" (30 mm) 9006PA30 0.47" (12 mm) XSZE112 0.7" (18 mm) XSZE118 1.18" (30 mm) XSZE130 XSZB1 9006PA XSZE Connector Cables (M12 or D suffix) XSZCD101Y Micro Conn., 4 pin, 2 m, straight XSZCD111Y Micro Conn., 4 pin, 2 m, 90 For additional cable options and lengths see p. 518 Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316 287 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Rectangular, Inductive Sensors Weld Field Immune, AC and DC XS Rectangular, Inductive Sensors / Weld Field Immune, AC and DC Features: Compact rectangular inductive proximity sensors for demanding applications including welding and machine tools. 1.30 33 * Housings - XSB: Plastic (thermoplastic polyester) k XSE: Plastic (fiber glass reinforced polyamide); screw terminal models can be offered also in slag resistant thermoset plastic 3.01 76.5 1.31 33.5 .63 16 1/2" NPT conduit ent. 2.36 60 Back view = * Noise and transient protection k Reverse polarity protection (DC models) k Selected models are offered with short circuit protection (SCP) and overload protection k UL Recognized and CSA Certified k Factory Mutual approved for non- incendive application, NAMUR sensors approved for intrinsically safe applications. Output Mode/ Sensing Face (XSE) 2xO4.2 = .16" dia. .78 20 * XSE models can be flush mounted in metal * Plug-in version for XSB k Screw terminals, PVC cable, mini style receptacle connections depending on the model k Weld Field Immunity (WFI) on most models k Radio Frequency Immunity (RFI) XSB Voltage Range Max. Load Current Residual (leakage) Current Operating Frequency Housing LED/SCPa/ Catalog WFI Number XSB 13mm (.511") sensing range, Non-shielded Not for Use on New Applications (XSB Only) y it il b a il a v A t c u d ro Limited P Proximity Sensors AC, 2 wire, plug-in, screw terminals, end sensing End a 1.02 26 1.95 49.5 1.02 26 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112 N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212 AC, 2 wire, plug-in, mini style connector, end sensing .49 12.5 N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112A N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212A .98 25 AC, 2 wire, non plug-in, 2m(6') cable, end sensing t Side b .78 20 N.O. N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112C N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212C AC, 2 wire, non plug-in, mini style connector, end sensing t LED XSE L=2 m N.O. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105112R 2xO4.2 .16" dia. N.C. 93-132 V 150 mA 4.5 mA (R) 10 Hz Polyester Yes/No/Yes XSBA105212R 1.2 mA 250 Hz Polyester No/No/No XSBC10710 DC, 2 wire, plug-in, not WFI N.O. 12-48 V 80 mA XSE 10mm (.393") sensing range, Shielded, DC models, 2 wire, N.O. Dual Dimensions inches mm 2m(6') cable End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071300 Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071330 Screw terminals End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC107130 Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC107133 Sealed cable (.8m - 2.6'), with pig-tailed mini style connector End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071302 Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071332 End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1072301 Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1072331 Sealed cable (.8m - 2.6'), with pig-tailed micro style connector End 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071301 Side 12-48 V 100 mA 0.5 mA 1000 Hz Polyamide Yes/Yes/Yes XSEC1071331 t a For side sensing, change last numeric digit as follows; Front: 1; Right: 3; Left: 4. Ex: XSB A105114C for left sensing. PLC Applications: R = Bleeder resistor needed. P = PLC compatible. For devices without SCP, see p. 298 for protective fuses. 288 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Rectangular, Inductive Sensors Weld Field Immune, AC and DC XS Rectangular, INductive Sensors / Weld Field Immune, AC and DC Specifications Wiring Mechanical 3 Blue Brown Black 2 BU - BN + BK Output + 1 0-8 mm (.31') for XSE Standard temperature range Enclosure rating 2 wire DC 0-9 mm (.35") for XSB Usable sensing range t -13 F to +158 F (-25 C to +70 C) NEMA Type 3, 4, 6, 12, 13 IEC Type IP67 Vibration resistance 25 G, amplitude 2 mm, f =10-55 Hz Shock resistance NO - 4 2 wire AC 3 L1 NO 4 L2 1 L1 NC 2 L2 XSE 2 wire type DC BN/3 NO BU/4 +/-/+ 50 G for 11 ms 40 x 40 mm (1.6" x 1.6") for XSB Standard target size (steel) 30 x 30 mm (1.18" x 1.18") for XSE Differential Max. 20% Repeatability Max. 5% Radio Frequency Immunity (RFI) Standard Screw terminals, #16 AWG Cable PvR, #20 AWG DC Models Electrical AC Models Voltage drop (across switch) 9.5 V 7V 4V Inrush current (inductive @ 20 mS) 0.9 A - - Minimum load current 30 mA 1.5 mA 1.5 mA On delay (max.) 40 ms .4 ms 12 ms XSB XSE Off delay (max.) 30 ms 1 ms 3 ms Power-up delay (max.) 80 ms 1.2 ms 16 ms Reverse polarity protection - Standard Standard Weld field immunity 100 mT Agency Listings (R) E 164353 c CCN NRKH LR 44087 Class 3211 03 Proximity Sensors Cable Connector 1 FM: J.I. OROH9.AX (3610, 3611) Refer to p. 351 for target material correction coefficient Km. t Options Description Suffix Extended temperature range to +185 F(+85 C) TT to -40 F(-40 C) TF 5 meter (16') cable length L05 Accessories XSE mounting brackets Catalog Number Flat XSEZ01 90 XSEZ02 Plug-in models - replacement modules, AC models Base receptacle AC ZSBZ11 AC, N.O. Plug in switch ZSBA105112 AC, N.C. Plug in switch ZSBA105212 Base receptacle DC ZSBZ12 DC, N.O. Plug in switch ZSBC10710 Minimum Mounting Clearances (mm/inches) Face to face Side by side e e XSE.15 XSB.20 e: 38/1.5" e: 80/3.1" e: 97/3.8" e: 160/6.3" Connector Cables (A or R3 suffix) XSZCA901Y Mini Conn., 3 pin, 2 m, straight XSZCA911Y Mini Conn., 3 pin, 2 m, 90 For additional cable options and lengths see p. 518 289 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Inductive Sensors; NAMUR, 2 Wire DC For use with an intrinsically safe barrier relay when used in hazardous locations Inductive Sensors; NAMUR, 2 Wire DC / For use with an intrinsically safe barrier relay when used in hazardous locations Cylindrical type 0 current I (mA) 4 Barrel Diameter Nominal Sensing Distance t Barrel Type 3 Operating Zone Operating Frequency Catalog Number Nickel plated brass case 2 1.65 Shielded, 2 m (6.6') cable 1 Sn Distance (mm) 4 mm smooth 0.03" (0.8 mm) 0-0.02" (0-0.6 mm) 1500 Hz XSLN08122 5 mm threaded 0.03" (0.8 mm) 0-0.02" (0-0.6 mm) 1500 Hz XSMN08122 6.5 mm smooth 0.04" (1 mm) 0-0.03" (0-0.8 mm) 1500 Hz XSLN01122 8 mm threaded 0.06" (1.5 mm) 0-0.03" (0-0.8 mm) 1500 Hz XSAN01122 Plastic case Shielded, 2 m (6.6') cable Proximity Sensors Principle of operation 2 wire NAMUR proximity sensors are characterized by the fact that their current consumption is changed by the presence of a metal object within the sensing zone. They differ from a standard sensor by the absence of an output circuit. All the processing is carried out by the associated amplifier or solid state system to which it is connected. The mode of operation is analogous to an N.C. contact: -- no object present: sensor is in the conducting state -- object present: sensor is in the non-conducting state 8 mm threaded 0.06" (1.5 mm) 0-0.05" (0-1.2 mm) 1000 Hz XSPN01122 12 mm threaded 0.08" (2 mm) 0-0.06" (0-1.6 mm) 800 Hz XSPN02122 18 mm threaded 0.2" (5 mm)( 0-0.16" (0-4.0 mm) 500 Hz XSPN05122 30 mm threaded 0.4" (10 mm) 0-0.31" (0-8.0 mm) 300 Hz XSPN10122 Non-shielded, 2m (6.6') cable 12 mm threaded 0.16" (4 mm) 0-0.12" (0- 3.2 mm) 400 Hz XSPN04122 18 mm threaded 0.31" (8 mm) 0-0.25" (0- 6.4 mm) 300 Hz XSPN08122 30 mm threaded 0.6" (15 mm) 0-0.47" (0-12.0 mm) 200 Hz XSPN15122 Plastic block type Nominal Sensing Distance t Enclosure Style Operating Zone Operating Frequency Catalog Number Shielded, terminal connections Limit switch style 0.6" (15 mm) 0-0.47" (0-12.0 mm) 100 Hz XSCN151229 Non-shielded, terminal connections Compact rectangular 0.5" (13 mm) 0-0.35" (0- 9.0 mm) 250 Hz XSBN10122 Block style 1.0" (25 mm) 0-0.8" (0-20.0 mm) 250 Hz XSBN25122 Block style - extended range 1.6" (40 mm) 0-1.25" (0-32.0 mm) 25 Hz XSDN501229 Applications Intrinsically safe applications (hazardous area). When used in these applications, it is imperative that (NAMUR) sensors be used only with an NY2 intrinsically safe relay/amplifier, or a suitably approved, compatible solid state system. Example: Painting line in car assembly plant. Factory Mutual System Approved for Div I, II hazardous location with NY2 safe barrier relay. Proximity switch t Refer to page 351 for target material correction coefficient Km. 290 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Inductive Sensors; NAMUR, 2 Wire DC For use with an intrinsically safe barrier relay when used in hazardous locations Inductive Sensors; NAMUR, 2 Wire DC / For use with and intrinsically safe barrier relay when used in hazardous locations Specifications Mechanical operation Standard temperature range NEMA Type Enclosure rating IEC Type -25 C to +70 C (-13 F to +158 F) storage -40 C to +80 C (-40 F to +176 F) 4mm & 5mm 1, 3, 4, 13 all others 3, 4, 6, 12, 13 4mm & 5mm IP64 all others IP67 Repeatability (% of Sr) 5% or less Cable 22 AWG (0.11 mm2), PvR 2 wire Electrical Voltage range 7 to 12 Vdc Current consumption from supply Sensor activated (target present) = 1 mA or less; 8.2 V (internal resistance: about 1 K) Sensor not activated (target absent) = 3 mA or more; Switching point defined for usable sensing distance and standard metal target: 1.65 mA Maximum line resistance Between sensor and amplifier: 50 ohms Apparent sensing capacitance t 280 nF maximum Apparent sensing inductance t 220 micro H maximum LR 15996 Class 3218 06 Agency Listings Consider for intrinsically safe systems. Proximity Sensors t FM: J.I. OROH9.AX (3610, 3611) NAMUR Sensors DC 2 wire, N.C. M: Metal case - P: Plastic case. M18x1 1.71 43.5 M12x1 1.45 37 M8x1 1.04 26.5 M8x1 1.57 40 1.18 30 6.5mm unthreaded 1.04 26.5 M5x0.5 1.18 30 4mm unthreaded Metal Metal Metal Metal Plastic Plastic Plastic XSLN08122 XSMN08122 XSLN01122 XSAN01122 XSPN01122 XSPN02122 XSPN05122 M30x1.5 Dimensions page 292 M12x1 M18x1 Dimensions page 288 Dimensions page 272 Dimensions page 280 1.71 43.5 M30x1.5 1.71 43.5 1.45 37 1.65 42 Sensors not suitable for flush mounting in metal Plastic Plastic Plastic Plastic Plastic Plastic Plastic Plastic XSPN10122 XSCN151229 XSPN04122 XSPN08122 XSPN15122 XSBN10122 XSBN25122 XSDN501229 Non-intrinsically safe applications (normal safe zone). connected to a solid state input (e.g.: TSX PLC input card, TSX DET 466) BN-1 Object present + Association with an NY2 power supply/relay amplifier unit Wiring diagram Ri = 1K + 7 to 12 Vdc _ BU-2 BN-1 Object absent + I < 1mA Ri = 1K - + I > 3mA (110 to 240V AC, P=5VA, 50 Hz). 2 NY2 BU - 4 2. F 2. 0 } - BN _ 1 + 7 to 12 Vdc BU-2 + proximity sensor 1. + Dual Dimensions inches mm 291 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Inductive Sensors Analog Output, DC XS Inductive Sensors / Analog Output, DC Features: Dimensions: a = overall length (mm) b = threaded section (mm) c = for non-shielded sensors (mm) * DC output current is directly proportional to the target distance thread M12x1 M18x1 M30x1 b c a Tubular Style dimensions (mm) 12 mm 18 mm 30 mm Metal Plastic Metal Plastic Metal Plastic a 1.9" (50) 1.9" (50) 1.9" (50) 1.6" (40.6) 1.9" (50) 2.07" (52.6) b 1.6" (42) 1.6" (42) 1.6" (42) 1.0" (26) 1.6" (42) 1.2" (32) c 0 0 0 8 0 0.5" (13) 1.57 40 1.57 40 2.36 60 4.5 114.5 1.77 45 1/2" NPT conduit ent. XSC * Two types of output: 3 wire: 0 - 10 mA, 0 - 16 mA 2 wire: 4 - 20 mA, 4 - 14 mA Nominal Enclosure Enclosure Sensing Style Material Distance 12 mm Diameter - 2 meter cable Voltage Range Max. 0.2 - 2 mm Shielded Metal 24 Vdc 0.4 - 4 mm Non-Shielded Plastic 24 Vdc 0.4 - 4 mm Non-Shielded Plastic 24-48 Vdc Circuit Type Output Current 2 wire 3 wire 2 wire 3 wire 2 wire 3 wire 4 - 20 mA 0 - 16 mA 4 - 20 mA 0 - 16 mA 4 - 14 mA 0 - 10 mA 2 wire 3 wire 2 wire 3 wire 2 wire 3 wire 4 - 20 mA 0 - 16 mA 4 - 20 mA 0 - 16 mA 4 - 14 mA 0 - 10 mA 2 wire 3 wire 2 wire 3 wire 2 wire 3 wire 4 - 20 mA 0 - 16 mA 4 - 20 mA 0 - 16 mA 4 - 14 mA 0 - 10 mA 2 wire 3 wire 2 wire 3 wire 4 - 14 mA 0 - 10 mA 4 - 20 mA 0 - 16 mA 2 wire 3 wire 2 wire 3 wire 4 - 14 mA 0 - 10 mA 4 - 20 mA 0 - 16 mA Operating Frequency Max. Catalog Number 1500 Hz XS1M12AB120 1500 Hz XS4P12AB120 1500 Hz XS4P12AB110 0.5 - 5 mm Shielded Metal 24 Vdc 500 Hz XS1M18AB120 0.8 - 8 mm Non-Shielded Plastic 24 Vdc 500 Hz XS4P18AB120 0.8 - 8 mm Non-Shielded Plastic 24-48 Vdc 500 Hz XS4P18AB110 300 Hz XS1M30AB120 300 Hz XS4P30AB120 300 Hz XS4P30AB110 60 Hz XSCH207629 60 Hz XSCH203629 50 Hz XSDH607629 50 Hz XSDH603629 30 mm Diameter - 2 meter cable 2 x .2" dia. 2 x 5.3mm dia. 1.18 30 1.5 40 2.56 65 .29 7.5 3.10 80 4 x dia. .21" 4 x dia. 5.5 mm * Both metal and plastic enclosures available 18 mm Diameter - 2 meter cable LED 3.90 100 Proximity Sensors 1. 1 28 * Three body styles: tubular, limit switch style (with 5 position turret head), block style LED 2.56 65 1/2" NPT conduit ent. XSD Dual Dimensions inches mm 1 - 10 mm Shielded Metal 24 Vdc 1.5 - 15 mm Non-Shielded Plastic 24 Vdc 1.5 - 15 mm Non-Shielded Plastic 24-48 Vdc Limit Switch Style - 2 meter cable 2 - 20 mm Non-Shielded Plastic 24-48 Vdc 2 - 20 mm Non-Shielded Plastic 24 Vdc Block Style - 2 meter cable 6 - 60 mm Non-Shielded Plastic 24-48 Vdc 6 - 60 mm Non-Shielded Plastic 24 Vdc Minimum Mounting Clearances (mm/inches) Side by side Face to face Facing a metal object Mounting in a metal support d h e e Side by side e Side by side Face to face Face to face e e 12 mm Shielded 12 mm Non-shielded, 24 V 12 mm Non-shielded, 48 V 18 mm Shielded 18 mm Non-shielded, 24 V 18 mm Non-shielded, 48 V 30 mm Shielded 30 mm Non-shielded, 24 V 30 mm Non-shielded, 48 V Limit switch style Block style e e Side by side Face to face Facing a metal object Mounted in metal e: 4 mm (0.16") e: 16 mm (0.63") e: 16 mm (0.63") e: 10 mm (0.39") e: 32 mm (1.26") e: 32 mm (1.26") e: 20 mm (0.79") e: 60 mm (2.36") e: 60 mm (2.36") e: 80 mm (3.15") e: 300 mm (11.81") e: 24 mm (0.94") e: 48 mm (1.89") e: 48 mm (1.89") e: 60 mm (2.36") e: 96 mm (3.78") e: 96 mm (3.78") e: 120 mm (4.72") e: 180 mm (7.08") e: 180 mm (7.08") e: 160 mm (6.30") not recommended e: 6 mm (0.24") e: 12 mm (0.47") e: 12 mm (0.47") e: 15 mm (0.59") e: 24 mm (0.94") e: 24 mm (0.94") e: 30 mm (1.18") e: 45 mm (1.77") e: 45 mm (1.77") d: 12 mm (0.47") d: 36 mm (1.42") d: 36 mm (1.42") d: 18 mm (0.71") d: 54 mm (2.12") d: 54 mm (2.12") d: 30 mm (1.18") d: 90 mm (3.54") d: 90 mm (3.54") h: 0 mm (0") h: 8 mm (0.31") h: 8 mm (0.31") h: 0 mm (0") h: 16 mm (0.63") h: 16 mm (0.63") h: 0 mm (0") h: 30 mm (1.18") h: 30 mm (1.18") 292 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors Analog Output, DC XS Inductive Sensors / Analog Output, DC Specifications Wiring Mechanical 2-wire Temperature range BN/1 mA + BK/4 -13 F to +158 F (-25 C to +70 C) Enclosure rating IEC Type IP67 Metal Output Current R BU/3 Tightening torque (max.) Is 3-wire BN/1 mA BK/4 BU/3 + Is 6 N*m 4.5 (lb-ft) 2 N*m 1.5 (lb-ft) 18mm 15 N*m 11.1 (lb-ft) 5 N*m 3.7 (lb-ft) 30mm 40 N*m 29.5 (lb-ft) 20 N*m 14.7 (lb-ft) Metal Enclosure material Plastic Output Voltage R U=R Is Plastic 12mm Wiring Tubular 22 AWG (0.34 mm2), PvR Limit Switch/Block style Screw term. 16 AWG(1.5 mm2) General Characteristics XS1kkkk120, XS4kkkk120: 15 - 38 Vdc Value of R (R = load impedance) 0 to 10 mA 1800 24 V 0 to 16 mA 1125 48 V 0 to 10 mA 4200 Ensure a minimum of 5 V between the + and sensor output Output current XS1kkk110, XS4kkk110: 15 - 58 Vdc Voltage limit (including ripple) XSCH207kkk, XSDH607kkk: 19 - 58 Vdc XSCH203kkk, XSDH603kkk: 19 - 30 Vdc Current consumption (no load) 4 mA Max. Output current drift with the rated operating temperature 10% Power Supply Current (no load) 4 mA Repeat Accuracy + - 1% + - 4% Protective Circuitry Short circuit protection yes Overload protection yes Reverse polarity protection yes Agency Listings (R) (XS1, XS4) E 164869 CCN NRKH (XSC, XSD) E 164353 CCN NKCR Proximity Sensors Linearity error LR 44087 Class 3211 03 Output Curves 4 to 20 mA, 2 wire connection (cylindrical models) Sn = 0.2...2 mm 20 16 2 8 4 0 0 3 6 9 12 15 18 21 24 27 Sensing distance/object (mm) 22 20 18 16 14 12 10 8 6 4 2 0 0 0.2 0.4 0.6 0.8 2 XSCH207629 1 20 2 8 4 0 0 10 0 0.5 2 1 1.5 2 2.5 3 3.5 4 4.5 0 5 1 2 3 4 XS4P18AB120 XS4P30AB120 Sn = 0.4...4 mm Sn = 1.5...15 mm O 12 mm 22 20 18 16 14 12 10 8 6 4 2 0 0 0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 0 0.8 1.6 2.4 3.2 4 4 4.8 5.6 6.1 7.2 8 Sensing distance/object (mm) Sensing distance/object (mm) 2 XSDH607629 O 18 mm 22 20 18 16 14 12 10 8 6 4 2 0 5 6 7 8 9 10 Sensing distance/object (mm) Sensing distance/object (mm) Sn = 0.8...8 mm 20 30 40 50 60 70 Sensing distance/object (mm) 1 XSDH603629 1.4 1.6 1.8 O 30 mm 22 20 18 16 14 12 10 8 6 4 2 0 XS4P12AB120 Output current Is (mA) Output current Is (mA) Sn = 6 0 mm 12 1 1.2 O 18 mm 22 20 18 16 14 12 10 8 6 4 2 0 Sensing distance/object (mm) XSDH20k629 16 Sn = 0.5...5 mm Output current Is (mA) 1 XSCH203629 XS1M30AB120 Sn = 1....10 mm Output current Is (mA) 12 O 12 mm XS1M18AB120 Output current Is (mA) 1 Output current Is (mA) Output current Is (mA) Sn = 20 mm Output current Is (mA) XS1M12AB120 XSCH20k629 O 30 mm 22 20 18 16 14 12 10 8 6 4 2 0 0 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15 Sensing distance/object (mm) Output Curves 0 to 10 mA, 3-wire connection, (cylindrical models) XS4M18AB110 O 12 mm 11 10 9 8 7 6 5 4 3 2 1 0 0 0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4 Sensing distance/object (mm) XS4P30AB110 Sn = 0.8...8 mm Output current Is (mA) Output current Is (mA) Sn = 0.4...4 mm O 18 mm Sn = 1.5...15 mm Output current Is (mA) XS4P12AB110 11 10 9 8 7 6 5 4 3 2 1 0 0 0.8 1.6 2.4 3.2 4 4.8 5.6 6.4 7.2 8 Sensing distance/object (mm) O 30 mm 11 10 9 8 7 6 5 4 3 2 1 0 0 1.5 3 4.5 6 7.5 9 10.5 12 13.5 15 Sensing distance/object (mm) 293 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XT Capacitive Sensors 12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC XT Capacitive Sensors / 12 mm 18 mm, 30 mm and Limit Switch Style; AC and DC Features Capacitive proximity sensors are ideal for sensing non-metal objects or for level control of fluids and granular material. A special wall mounting bracket has been designed to replace thick or metal walls the sensor is not capable of penetrating. The actual sensing range varies widely depending on the target material and environmental conditions (humidity, dust, etc.). An internal compensation electrode is incorporated to suppress the effects of material deposits on the sensor's face. The threshold level is adjustable via a 20 turn potentiometer (except 12mm) located at the rear of the switch. This adjustment can be used to zero out the presence of a plastic tube allowing the switch to sense "through" a bulk material or liquid level. XT1/4 Threaded Other features include: metal housing: nickel plated brass, plastic housing: PBT; can be flush mounted in metal (except XT4); LED indication for output in closed state; mounting nuts included for threaded models; mounting bracket included for non-threaded versions, well mounting brackets are optional; sensitivity adjustment tool included; UL & CSA; CE mark. XT1/4 Smooth thread M12x1 Nominal Sensing Distance AC or DC Output Mode Circuit Type Voltage Range Operating Frequency Catalog Number 100 Hz 100 Hz 100 Hz XT1M12PA372 XT1M12PB372 XT1M12NA372 12 mm diameter, 2m (6.6') cable, Non Adjustment Flush Mountable -- Threaded Metal Case thread Proximity Sensors M18x1 2 mm 2 mm 2 mm DC DC DC N.O. N.C. N.O. PNP PNP NPN 12 - 24 V 12 - 24 V 12 - 24 V 18 mm diameter, 2m (6.6') cable, with Sensitivity Adjustment thread M30x1.5 XS7 Limit Switch Style Flush Mountable -- Threaded Metal Case 5 mm 5 mm 5 mm 5 mm 5 mm AC AC DC DC DC N.O. N.C. N.O. N.C. N.O. 2 wire 2 wire PNP PNP NPN 24 - 240 V 24 - 240 V 12 - 24V 12 - 24V 12 - 24V 25 Hz 25 Hz 100 Hz 100 Hz 100 Hz XT1M18FA262 XT1M18FB262 XT1M18PA372 XT1M18PB372 XT1M18NA372 24 - 240 V 12 - 24V 12 - 24V 25 Hz 100 Hz 100 Hz XT4P18FA262 XT4P18PA372 XT4P18NA372 Non-Flush Mountable -- Threaded Plastic Case 8 mm 8 mm 8 mm AC DC DC N.O. N.O. N.O. 2 wire PNP NPN 30 mm diameter, 2m (6.6') cable, with Sensitivity Adjustment Flush Mountable -- Threaded Metal Case Well Bracket XTAZ Level Detection 10 mm 10 mm 10 mm 10 mm 10 mm AC AC DC DC DC N.O. N.C. N.O. N.C. N.O. 2 wire 2 wire PNP PNP NPN 24 - 240 V 24 - 240 V 12 - 24V 12 - 24V 12 - 24V 25 Hz 25 Hz 100 Hz 100 Hz 100 Hz XT1M30FA262 XT1M30FB262 XT1M30PA372 XT1M30PB372 XT1M30NA372 24 - 240 V 24 - 240 V 12 - 24V 12 - 24V 25 Hz 25 Hz 100 Hz 100 Hz XT4P30FA262 XT4P30FB262 XT4P30PA372 XT4P30NA372 Non-Flush Mountable -- Threaded Plastic Case 15 mm 15 mm 15 mm 15 mm AC AC DC DC N.O. N.C. N.O. N.O. 2 wire 2 wire PNP NPN 32 mm diameter, 2m (6.6') cable, with Sensitivity Adjustment Flush Mountable -- Smooth Plastic Case 15 mm 15 mm (a) Front face AC AC N.O. N.C. 2 wire 2 wire 110 - 220 V 110 - 220 V 10 Hz 10 Hz XT1L32FA262 XT1L32FB262 2 wire 2 wire 110 - 220 V 110 - 220 V 10 Hz 10 Hz XT4L32FA262 XT4L32FB262 25 Hz 100 Hz 100 Hz XT7C40FP262 XT7C40PC440 XT7C40NC440 Non-Flush Mountable -- Smooth Plastic Case 20 mm 20 mm AC AC N.O. N.C. Limit Switch Style, 0.5" NPT, with Sensitivity Adjustment Flush Mountable -- Plastic Case 15 mm 15 mm 15 mm AC DC DC N.O. or N.C. N.O. / N.C. N.O. / N.C. 2 wire PNP NPN 24 - 240 V 12 - 24V 12 - 24V Sensitivity Adjustment (b) Contamination Main electrode Earth electrode Compensation electrode (a) : compensation field (suppression of external contamination) (b) : main electric field 1 2 1 Sensitivity adjustment potentiometer and output state indicator ( yellow LED ) 2 Adjustment using screwdriver 294 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XT Capacitive Sensors 12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC XT Capacitive Sensors / 12 mm, 18 mm, 30 mm, 32 mm and Limit Switch Style; AC and DC Specifications Wiring Mechanical Enclosure Rating -13 F to +158 F (-25 C to +70 C) NEMA Type 4, 4X, 6, 6P, 12, 13 (Except Smooth Case 4, 4X, 6, 12) IEC Type IP67 (Except Smooth Case -- IP63) 20% 10% 5 L1 Differential (%of Sr.) Repeatability (% of Sr.) 6 L2 Electrical AC Models (All) Smooth DC Models Voltage Range Voltage Limit Voltage Drop (across switch) Closed State Minimum Load Current 24 - 240 V 20 - 264 V 5.5 V 5 mA 300 mA 350 mA - 1.5 mA at 120V 50 ms 20 ms 50 ms 30 ms 300 ms 150 ms 110 - 220 V 90 - 250 V 9V 15 mA 250 mA (Ue=110Vt) - - 7 mA 50 ms - 15 ms - 300 ms - 12 - 24 V 10 - 38 V 2V 0 mA 300 mA 200 mA 10 mA - 5 ms 5 ms 5 ms 5 ms 30 ms 30 ms GR / YW 3-wire DC, N.O. or N.C. output XT1M12FlA372, XT1M12PB372 BN /1 PNP + BK /4 (NO) BK /2 (NC) Tubular Limit Switch Maximum Load Current Current Consumption @ No Load Residual Leakage Current BU /3 Tubular Limit Switch Tubular Limit Switch Tubular Limit Switch Electrostatic Discharges Radio Magnetic Fields Fast Transients Impulse Voltage E 164869 CCN NRKH On Delay Max BN /1 NPN + Off Delay Max. BK /4 (NO) BK /2 (NC) Power-up Delay Max. BU /3 2-wire AC, programmable N.O. or N.C. output depending on position of jumper XT7C40FP262 5 L1 6 L2 Protective Circuitry NO Agency Listings IEC 60947-5-2 and NEMA ICS 5, Part 4 LR 44087 Class 3211 03 (R) NC 7 1 PNP NC 2 NO 4 3 1 NPN NO 4 NC 2 3 t Maximum load current 150mA when Ue=220V. The operating distance of the sensor is related to the dielectric constant () of the object material to be detected. The higher the value of , the easier it will be for the object to be detected. NOTE: This product should not be used in an environment with dew or condensation The Usable Sensing Distance depends on the object material: Su = Sn x Fc Su = Usable Sensing Distance; Sn = Nominal Sensing Distance; Fc = Correction Coefficient for the object material Example: Sensor XT1M30PA372 used to detect a rubber object Sn = 10 mm, Fc = 0.3 Usable Sensing Distance Su = 10 mm x 0.3 = 3 mm XSZB1kk 9006PAkk Material Fc Material Fc Acetone 20 0.8 Paper 2-4 0.2-0.3 Air 1 0 Paraffin 2-2.5 0.2 Alcohol 24 0.85 Petrol 2.2 0.2 Ammonia 15-25 0.75-0.85 Plexiglass 3.2 0.3 Cement (powder) 4 0.35 Polyester resin 2.8-8 0.2-0.6 Cereals 3-5 0.3-0.4 Polystyrene 3 0.3 Damp wood 10-30 0.7-0.9 Porcelain 5-7 0.4-0.5 Dry wood 2-7 0.2-0.6 Powered Milk 3.5-4 0.3-0.4 Ethylene glycol 38 0.95 Rubber 2.5-3 0.3 Epoxy resin 4 0.36 Salt 6 0.5 Flour 2.5-3 0.2-0.3 Sand 3-5 0.3-0.4 Glass 3-10 0.3-0.7 Sugar 3 0.3 Marble 6-7 0.5-0.6 Teflon 2 0.2 Mica 6-7 0.5-0.6 Vaseline 2-3 0.2-0.3 Nylon 4-5 0.3-0.4 Water 80 1 Oil 2.2 0.2 Accessories XSZEkkk XTAZ3k Size Description Catalog Number 18mm 18mm 18mm 18mm 30mm 30mm 30mm 30mm 30mm 32mm 32mm Plastic mounting nuts Metal mounting nuts Plastic mounting bracket Metal mounting bracket Plastic mounting nuts Metal mounting nuts Plastic mounting bracket Metal mounting bracket Well mounting bracket Well mounting bracket Surface mounting bracket XSZE218 XSZE118 XSZB118 9006PA18 XSZE230 XSZE130 XSZB130 9006PA30 XTAZ30 XTAZ32 XUZB32 Well mounting bracket 295 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Standard Temperature Range 2-wire AC, N.O. or N.C. output XT1L32Fl262, XT4L32Fl262 Proximity Sensors XT Capacitive Sensors 12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC XT Capacitive Sensors / 12 mm, 18 mm, 30 mm, 32 mm and Limit Switch Style; AC and DC Minimum Mounting Clearances Face to face Facing a metal object e Mounted in metal d h Side by side e e Side by side Face to face Flush mounting Sensitivity adjustment potentiometer e e To avoid influence of the immediate surroundings it maybe necessary to reduce the sensitivity when flush mounting the sensor. Proximity Sensors Side by Side (mm/in) Face to Face (mm/in) Facing a Metal Object (mm/in) Mounting in Metal (mm/in) 18 mm e: 0 e: 30/1.18 e: 30/1.18 d: 18/.71 h: 0 30 mm e: 0 e: 60/2.36 e: 60/2.36 d: 30/1.18 h:0 32 mm e: 0 e: 100/3.94 e: 100/3.93 d: 32/1.26 h:0 x: 2/.07 Minimum Mounting Clearances XT1 Flush Mountable XT4 Non-Flush Mountable XT7 Limit Switch Style 18 mm e: 40/1.57 e: 50/1.97 e: 80/3.15 d: 18/.71 h: 0 30 mm e: 60/2.36 e: 80/3.15 e: 100/3.94 d: 90/3.54 h: 20/.79 32 mm e: 60/2.36 e: 100/3.94 e: 100/3.94 d: 96/3.78 h: 25/.98 e: 40/1.57 e: 120/4.72 296 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XT Capacitive Sensors 12mm, 18mm, 30mm, 32mm and Limit Switch Style; AC and DC XT Capacitive Sensors / 12 mm, 18 mm, 30 mm, 32 mm and Limit Switch Style; AC and DC Dimensions (mm/in.) XT1/4 XT7 40 1.57 (4) a b 60/2.36 60/2.36 80/3.15 51/2.03 51/2.03 n/a (1) Output LED (2) Supply LED (depending on model) (3) 1 entry threaded for 0.5 NPT (4) 2 elongated holes 5.3 X 7mm (0.21 X 0.28") (2) 41 1.6 (1) 2 x O 5.3 2 x 0.21 dia. (3) a = Overall b = Threaded Section 60 2.36 XTlM18 XTlM30 XTlM32 a 117 4.6 Dimensions (mm/in) 25 .98 a b 20 .79 40 1.57 16 .63 24 .94 30 40 1.18 1.57 Accessories Dimensions (mm/in.) XUZB32 38.3 1.51 32mm Dia 1.26" Dia (2) a1 XSZ a B112 a 22 .86 25 (1) .98 40 1.57 3.5 .14 (1) B118 8 .31 B130 21.9 0.86 26 1.02 39 1.53 a1 b b1 b2 14.5 0.57 15.7 0.62 21.7 0.85 16 0.63 22 0.87 35.5 1.40 15.5 0.61 20.1 0.80 31 1.22 8.5 0.33 11.5 0.45 18.5 0.73 Dia. 15 .69 18 60 2.36 (1) maximum value (2) 2 holes 5.5mm (.22 in) Clamp supplied with two M5 screws. HM head 30 (1) 2 elongated holes 4 X 8mm (0.16 X 0.31 in) XTAZ30 50 1.97 12 XTAZ32 9.39 50.8 2.00 44.4 1.75 .37 1.52 .06 25.4 1.00 M30 X 1.5 44.4 1.75 .50 30.9 1.312 30.9 1.52 .06 12.7 25.4 1.00 34.2 1.348 25.4 1.00 1.219 dia. 50.8 2.00 50.8 2.00 dia. 1 1/2 X 12 UNF Thread 1.219 dia. 4 .16 (2) b1 b2 b Dia. Proximity Sensors XSZB112, B118, B130 50.8 2.00 dia. 10/32 Set screw 1 1/2 X 12 UNF Thread 9006PAll C L M H J D Full R B E "K" hole F G A Type A B C D E F G H J K L M IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm PA30 2.54 67 2.56 65 1.39 35 1.99 51 0.39 10 1.28 33 1.97 50 0.21 5 2.05 52 1.20 31 0.08 2 0.98 25 PA18 2.05 52 1.97 50 0.98 25 1.60 41 0.39 10 0.98 25 1.38 35 0.21 5 1.65 42 0.73 19 0.08 2 0.79 20 PA12 1.38 35 1.57 40 069 18 1.20 31 0.39 10 069 18 0.98 25 0.21 5 1.28 33 0.49 13 0.08 2 0.71 18 297 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Inductive Sensors Mounting Accessories XS Inductive Sensors / Mounting Accessories Protective fuses For AC and AC/DC proximity sensors which do not incorporate overload and short circuit protection, the use of a "quick- blow" fuse connected in series with the sensor is recommended. XUZE08 Description 9006PAkk Catalog Number 0.6A "quick-blow" cartridge fuse (5x20) (XSB proximity sensors) (Use with 9080 IEC 5 X 20 fuse block - See Digest 172, page 22-17) 0.8A "quick-blow" cartridge fuse (5x20) (XS dia. 8, 12, 18, 30, and XSD proximity sensors) (Use with 9080 IEC 5 X 20 fuse block - See Digest 172, page 22-17) Sold in lots of 10 XUZE06 Sold in lots of 10 XUZE08 Mounting brackets Description XSZB1kk Cylindrical inductive proximity sensors 8316kk Proximity Sensors Zinc die cast for cylindrical 4-12 mm dia. Metal plate bracket XSEZ01 XSEZ02 2 Zamac nuts, nickel and chromium plated with 2 lock washers 2 Plastic nuts Stainless steel mounting nuts Stainless steel locknut washers XSZP1kk For use with Catalog Number XS1L04 XS1N05 XS1/XS2 L06 XS1/XS2/XS4 12 (M12 x 1) XS1/XS2/XS4 18 (M18 x 1) XS1/XS2/XS4 30 (M30 x 1.5) XS1/XS2/XS4 4mm 5mm 6mm 8mm 12mm Straight Right angled XS1L04 XS1L05 XS1/XS2 L06 XS1/XS2/XS4 XS1/XS2/XS4 XSE XSE XSZB104 XSZB105 XSZB165 XSZB108 XSZB112 9006PA12 XSZB118 9006PA18 XSZB130 9006PA30 831604 831605 831606 831608 831612 XSEZ01 XSEZ02 Mounting nuts Description XSZEkkk Sensor Diameter 4 unthreaded 5 (M5 x 0.5) 6.5 unthreaded 8 (M8 x 1) Protective cable end, (CNOMO type) Flat mounting plate 90 Angle flat mounting plat XSZBk00 Substitution mounting bracket Protective cover Sensor Diameter For use with Catalog Number 5 (M5 x 0.5) 8 (M8 x 1) 12 (M12 x1) 18 (M18 x 1) 30 (M30 x 1.5) 8 (M8 x 1) 12 (M12 x1) 18 (M18 x 1) 30 (M30 x 1.5) 12 (M12 x1) 18 (M18 x 1) 30 (M30 x 1.5) 8 (M8x1) 12 (M12 x1) 18 (M18 x 1) 30 (M30 x 1.5) 12 18 30 - - - - - - - - - - - - - - - - XS1N05 XS1/XS2 XS1/XS2 XS1/XS2 XS1/XS2 XS4 XS4 XS4 XS4 XS1/XS2 XS1/XS2 XS1/XS2 XS1/XS2 XS1/XS2 XS1/XS2 XS1/XS2 XS1/XS2/XS4 XS1/XS2/XS4 XS1/XS2/XS4 XS*J XS*F XS*E XS*C XS*D XS*J XS*F XS*E XS*C XS*D XS*E XS*C XS*D XS*E XS*C XS*D XSZE105 XSZE108 XSZE112 XSZE118 XSZE130 XSZE208 XSZE212 XSZE218 XSZE230 XSZE312 XSZE318 XSZE330 XSZE908 XSZE912 XSZE918 XSZE930 XSZP112 XSZP118 XSZP130 XSZBJ00 XSZBF00 XSZBE00 XSZBC00 XSZBD00 XSZBJ90 XSZBF90 XSZBE90 XSZBC90 XSZBD90 XSZBE10 XSZBC10 XSZBD10 XSZEE10 XSZEC10 XSZED10 298 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors Mounting Accessories, Dimensions XS Inductive Sensors / Mounting Accessories, Dimensions Mounting brackets XSZB104/105 XSZB165/108/112/118/130 .59 15 6.7 .48 12.3 h b .15 4 .11 3 .33 8.5 e .31 8 d2 1.50 38.3 d1 .13 3.5 c a .15 4 .86 22 .31 8 2 elongated holes 4 (screw) x 8 XSEZ01 c mm IN e XSEZ02 mm IN mm IN mm IN mm .15 4 8 4mm XSZB104 .15 4 Unthreaded XSZB105 .19 5 6.5 mm XSZB165 Unthreaded .25 6.5 .78 19.9 .55 14.0 .57 14.5 .29 7.5 .49 12.5 8mm XSZB108 .31 8.0 .78 19.9 .55 14.0 .57 14.5 .29 7.5 .49 12.5 12mm XSZB112 .47 12.0 .86 21.9 .63 16.0 .57 14.5 .33 8.5 .21 15.5 18mm XSZB118 .70 18.0 1.00 26.0 .86 22.0 .61 15.7 .45 11.5 .79 20.1 30mm XSZB130 1.18 30.0 1.53 39.0 1.40 35.5 .85 21.7 .72 18.5 1.20 31.0 = 1.97 50 .98 25 = .47 12 = 1.97 50 .98 25 = .07 2 5mm 2 X M3 2 X M3 h .07 2 .98 25 mm IN b .49 12.5 IN mm IN a 1.61 41 Brackets d2 .35 .78 9 20 Sensors d1 .78 20 .47 12 Approximate Dimensions 9006PAkk 8316 Bracket L C 1.5 M E Full R D .625 .201 dia thru .375 dia C bore B H "K" Hole .980 J G F A No. 8-32 UNC 2B Type 2 tap .260 dia Dual Dimensions inches mm .625 Type A B C D E F G H J K L M IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm PA30 2.64 67 2.56 65 1.39 35 1.99 51 0.39 10 1.28 33 1.97 50 0.21 5 2.05 52 1.20 31 0.08 2 0.98 25 PA18 2.05 52 1.97 50 0.97 25 1.60 41 0.39 10 0.98 25 1.38 35 0.21 5 1.65 42 0.73 19 0.08 2 0.79 20 PA12 1.38 35 1.57 40 0.69 18 1.20 31 0.39 10 0.69 18 0.98 25 0.21 5 1.28 33 0.49 13 0.08 3 0.71 18 299 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors = .15 4 = 2X3 (screw) .31 8 .39 10 .35 9 Proximity Sensors XS Inductive Sensors Mounting Accessories, Dimensions XS Inductive Sensors Mounting Accessories, Dimensions XSZBJ00 XSZBF00 M3 0.24 6.1 0.74 19 M3 0.78 20 M3 0.06 15 0.31 8 0.21 0 5.5 0.27 7 1.08 27.5 0.47 12 0 0.39 0.20 5.1 M3 0.88 22.5 1.35 34.5 XSZBE00 XSZBC00 1.90 48.5 1.6 42 0.67 17 0.23 0 3 6 0.20 5 0.63 16 1.18 30 0 0.39 10 M5 0.40 10 M3 1.08 27.4 0.47 11.9 XSZBD00 XSZBJ90 0.40 10.2 0.41 0.31 10.5 8 14 4 0.88 22.5 0.20 5.1 M3 M3 0.16 0 4 3.14 80 XSZBF90 XSZBE90 1.35 34.5 1.2 32 6.1 M3 1.21 30.8 0.94 23.9 M3 0.40 10 M3 M3 1.08 27.4 0.78 20 0.67 17 9 45 4.5 16 0.59 15 0.72 18.5 0.47 0 12 3.14 80 3.29 83.7 Proximity Sensors 3.0 77.2 0.18 0.47 4.5 0 12 1.15 29.4 Dual Dimensions inches mm 300 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS Inductive Sensors Mounting Accessories, Dimensions XSZBC90 XSZBE10 0.63 16 1.67 42.5 1.65 42 0.39 10 1 1.18 30 M5 1.45 36 9 36.9 1.53 39 0.98 25 1.74 44.3 XSZBD10 XSZBC10 2.55 65 M5 3.14 80 2.55 65 1.18 30 1.61 41 M5 Proximity Sensors 1.74 44.4 1.37 3 35 M3 2.16 55 0.55 14 0.11 1.61 2.8 41 1.65 42 3.14 80 XSZEE10 XSZEC10 0.30 7.8 M3 1.29 33 M4 1.18 30.2 1.29 33 0.78 20 1.18 30 2 30.2 0.26 6.8 1.15 47.1 0.64 16.4 1.74 44.2 2.44 62.1 XSZED10 0 0.55 14 2.55 65 3.48 88.5 2.55 65 M5 1.13 28.8 3.48 88.5 Dual Dimensions inches mm 4.51 114.8 301 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors SG Magnet Actuated Sensors Surface Mounted Style SG Magnet Actuated Sensors / Surface Mounted Style Surface mounted magnet actuated sensors for industrial applications. Telemecanique R.B. Denison Mag. Switch 80 SGA-8016 * Sensing is independent of magnet polarity * Typical applications: security systems (gate interlocks), high speed rotational counting, identification of metal bins with magnet coded "labels", sensing through non magnetic walls, etc. Features: 10VA MAX. (RES.) 200VDC/0.5A MAX made in USA * Housing; aluminum, plastic (PBT) for SG08168 and SG28195 * Completely epoxy encapsulated * Very fast response time (reed output only) * PLC compatible AC models (triac output) * High transients protection (AC models) * No bouncing. Magnet actuated proximity sensors Circuit Type AC ratings VA (max.) DC ratings Volts j Current (max.) VA (max.) Volts (max.) Dim. Leakage Fig. Current (mA) No. (max.) Wiring Fig. Catalog Number Proximity Sensors Reed output - DC only N.O. - - - 10 200 0.5 A 0 1 A SGA8016 N.O. - - - 10 200 0.5 A 0 2 A SGA8031 200 0.5 A 0 1 A SGA8182 200 0.5 A 0 1 A SGA8053 Reed output - DC only - built-in resistor protection N.O. - - - 10 Reed output - DC only - High temperature -40 F to 300 F N.O. - - - 10 Reed output - AC and DC - built-in RC protection N.C. 3 130 0.25 A 3 100 0.25 A 6 (R) 2 B SGB8175 N.O. 10 130 0.5 A 10 200 0.5 A 6 (R) 2 A SGA8176 N.O. 10 130 0.5 A 10 200 0.5 A 6 (R) 1 A SGA8177 Triac output - AC only (inductive PLC) N.O. 240 120 2.0 A - - - 1.7 (P) 3 A SG08168 a N.O./N.C. 50 240 0.5 A - - - 1.7 (P) 3 C SG28195 a N.O. 50 130 0.5 A - - - 1.7 (P) 1 A SG08239 j a PLC applications: P = PLC compatible. R = Bleeder resistor required. For reed output: max. voltage. For triac output: nominal voltage. UL Recognized Magnet actuators Sensing distance Tubular All SG2 8195 Catalog Number 1.3" (33mm) 1" (25.4mm) 7046 Flat bracket, center South pole 0.7" (17.7mm) 0.4" (10mm) 7093 Flat bracket, side South pole 0.5" (12.7mm) 0.2" (5mm) 7063 90 bracket South pole 0.5" (12.7mm) 0.2" (5mm) 7062 Block type 0.5" (12.7mm) 0.2" (5mm) 7099 Flexible tape 1' long 0.3" (7.6mm) 0.2" (5mm) 7096 All block sensors except SG28195. 302 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors SG Magnet Actuated Sensors Surface Mounted Style SG Magnet Actuated Sensors / Surface Mounted Style Specifications Wiring Mechanical Figure A (N/O) LOAD Figure B (N/C) LOAD Figure C (N/O or N/C) Black Red White LOAD LOAD Standard temperature range -40 F to +140 F (-40 C to +60 C) (to 300 F for SGA 8053) Enclosure ratings (NEMA) Type 1, 4, 13 Vibration resistance 20 G (10 to 2000 Hz) Shock resistance 50 G for 11 mS Differential Max. 75% Repeatability 0.003" Electrical AC (triac) Voltage drop (across switch) 2V 0 V (IR for SGA8182) Minimum load current 15 mA - On delay (ms) 1 ms 0.75 ms Off delay (ms) 8 ms 0.75 ms Cable 3' #22 AWG vinyl except SGO8168: #16 AWG SJTO, 2 individual Teflon #22 AWG for SGA8053 Agency Listings (R) DC E 42259 CCN NKCR2 (SGO8168 and SG28195 only) Voltage drop = IR where I= load current, R = 150 Options Suffix Teflon (SGA8053) L02 5 meters (16') of individual wires Teflon (SGA8053) L05 Vinyl L05 SJTO (SGO8168) L05 10 meters (33') of cable, (for triac and models with built Vinyl in resistor) SJTO (SGO8168) L10 5 meters (16') of cable Proximity Sensors Cable Type 2 meters (6') of individual wires L10 Ex: SGO8168L05 Dimensions 1.75 44 2.00 50.8 1.00 25 .5" NPT conduit entrance 1.25 31.75 .875 22.2 1.25 31.75 1.00 25.4 .875 22 1.25 31.75 .75 19 Figure 1 2 x .187 dia. SGA8016 Figure 2 SGA8031 SGA8177 SGA8175 SGA8182 .200 dia. SGA8053 .406 dia. C. Bore SGA8176 .625 15.88 .980 24.89 1.562 39.67 SGO8239 .310 7.87 2.080 52.82 Figure 3 SGO8168 SG28195 Dual Dimensions inches mm 303 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors SG Magnet Actuated Sensors Limit Switch Style SG Magnet Actuated Sensors / Limit Switch Style Limit switch style magnet actuated proximity sensors for heavy duty industrial applications. * Sensing is independent of magnet polarity * Typical applications: security systems (gate interlocks), high speed rotational countings, identification. Features: * Housing; zinc die-cast * Completely epoxy encapsulated * Plug in models for fast replacement * Very fast response time (reed output only) * PLC compatible AC models Non plug-in * High transient protection * Overload and short protection (transistor models) * No bouncing * 0.5" NPT conduit entrance. * UL recognized (except where indicated). Proximity Sensors Circuit Type AC ratings (inductive or resistive) VA (max.) Volts (nom.) Current (max.) VA (max.) DC ratings (resistive only) Volts (max.) Dim. Leakage Fig. Current (mA) No. (max.) Wiring Catalog Fig. Number AC triac output, non plug-in N.O. 360 120 3.0A - - - 1.7 (P)q 1 A SG08003 N.C. 360 120 3.0A - - - 1.7 (P)q 1 B SG18004 Non plug-in with light indicator N.O. 360 120 3.0A - - - 1.7 (P)q 1 A SG0L8003 N.C. 360 120 3.0A - - - 1.7 (P)q 1 B SG1L8004 DC, transistor output, non plug-in N.O. - - - 7.5 30 0.25 A 0 1 D SG08079 N.C. - - - 7.5 30 0.25 A 0 1 E SG18056 Reed output, non plug-in (AC model has built-in surge RC protection) N.O. - - - 10 200 0.5 A 0 1 A SGA8005 N.O. 15 120 1.0A 15 250 1.0 A 6 (R)q 1 A SGA8040 N.O./N.C. - - - 3 200 0.25 A 0 1 C SGC8027 N.O./N.C. - - - 20 500 1.5 A 0 3 C SGC8025 q (P)=PLC compatible. (R) Bleeder resistor required for PLC compatibility. Magnet actuators (See page 310) inches (mm) Tubular To all others 8079 Sensing distance 1.3" (33) 8040 8027 8025 Catalog Number 1.2" (30.5) 0.8" (20.3) 0.9" (23) 1" (25.4) 7046 Flat bracket, center South pole 0.7" (17.7) 0.5" (12.7) 0.4" (10.1) 0.4" (10.1) 0.4" (10.1) 7093 Flat bracket, side South pole 0.5" (12.7) 0.4" (10.0) 0.2" (5.1) 0.2" (5.1) 0.2" (5.1) 7063 90 bracket South pole 0.5" (12.7) 0.4" (10.1) 0.2" (5.1) 0.2" (5.1) 0.2" (5.1) 7062 Block type 0.5" (12.7) 0.2" (5.1) 0.2" (5.1) 0.3" (7.6) 0.2" (5.1) 7099 Flexible type - 1' long 0.3"(7.6) - 0.2" (5.1) 0.1" (2.5) 7096 t 0.1" (2.5) All sensors except the ones tabulated separately at right. 304 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors SG Magnet Actuated Sensors Limit Switch Style SG Magnet Actuated Sensors / Limit Switch Style Specifications Wiring General characteristics Figure A L2 L1 LOAD -40 F to 140 F (-40 C to 60 C) Temperature range -40 F to 125 F (-40 C to 52 C) for transistor models Enclosure ratings NEMA Type Vibration resistance Figure B L1 L2 1,4,13 20G (10 to 2000Hz) Shock resistance 50G for 11ms Differential Max. 75% Repeatability 0.003" AC triac Transistor 2V - - Minimum load current (max.) 15 mA - - SGA8005 SGA8040 SGS8027 SGC8025 On delay (max.) 0.75 ms 0.75 2 ms 1 ms N.O./ 1.5 ms N.C. 2 ms N.O./ 4 ms N.C. 0.75 ms 0.75 2 ms 11 msN.O. 1.5 ms N.C. 2 msN.O./ 4 ms N.C. LOAD Voltage drop (across switch) Reed Figure C NO 1 ms LOAD Com Off delay (max.) NC LOAD Cable - screw terminals Terminal strip marked: NO-COM-NC Figure D + (R) E 42259 CCN NKCR2 Options - triac models only Com LOAD Description Fig. Suffix adder 3' 16-3 SJTO vinyl cable, epoxy sealed A,B 320 3' 16-3 SJTO vinyl cable, cord connector A,B 321 3' 16-4 SJTO vinyl cable, epoxy sealed C,D,E 420 3 pin mini style receptacle See p. 518 for matching connector cables. Dimensions Sensing face 1.34 34 .28 7 .71 18 LOAD #10-32 x .375 deep Mtg. holes tapped from back 2.34 59 Com + #10-32 x .375 deep Mtg. holes tapped from back .203 dia. Mtg holes. thru 4.06 103 Sensing face Figure E + 347 2.34 59 SG18056 is normally closed. Connect red terminal (+) to power source. Connect minus (-) terminal to load. Housing must be connected to minus. Proximity Sensors + #16 AWG Agency Listings except where noted .203 dia. Mtg holes. thru Figure 1 1.15 29 non-plug-in 1.62 41 1.15 29 SGA8005 SGO8003 SGC8027 Figure 2 Style C 1.62 41 SGC8025 SGI8056 SGO8056 SGI8004 3.42 86 SGO8040 SGO8079 .84 21 1.75 44 Dual Dimensions inches mm 1.75 44 .84 21 305 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors SG Magnet Actuated Sensors Tubular Style SG Magnet Actuated Sensors / Tubular Style 1.00 25 2.25 57 1.25 31 1"-14 UNS -2A Thread Tubular magnet actuated proximity sensors for heavy duty applications such as: high speed rotational counting, identification of metal bins with magnet coded "labels" sensing through non-magnetic walls, etc. * Sensing is independent of magnet polarity Features: * Housings - Aluminum SGA8057; Plastic PVC SGC8058, SGA8072, SGA8039; Polymide SGA8179, SGA8180, SGA8181 * Completely epoxy encapsulated Figure 1 * High transient protection SGA8057 (Aluminum) SGC8058 (PVC) SGA8072 (PVC) SGA8189 (Brass) * Threaded and smooth housings * High voltage versions * SPST and SPDT models * No bouncing. .70 18 1.09 27 Circuit type .15 4 .945 24 M18 x 1 Thread 2 locking nuts furnished with each sensor AC ratings (inductive or resistive) VA (max.) Volts nominal DC ratings (resistive only) Current (max.) VA (max.) Leakage Volts Current (mA) (max.) (max.) Dim. Fig. No. Wiring Fig. Catalog Number Reed output AC & DC switching (Built-in RC protection), threaded. N.O. 15 120 1.0 A 12 48 0.25 A 6 1 A SGA8057 N.O./N.C. 15 120 1.0 A 15 100 1.0 A 6 1 C SGC8058 N.O. 15 120 1.0 A 15 250 1.0 A 6 1 A SGA8072 N.O. 25 480 1.0 A 25 480 1.0 A .16 2 A SGA8179 a Reed output - DC, threaded, resistor built-in for long cable runs Figure 2 SGA8179 SGA8180 SGC8181 N.O. - - - 10 200 0.5 A 0 2 A SGA8180 a N.O./N.C. - - - 3 100 0.25 A 0 2 C SGC8181 a 1.0 A 6 3 A SGA8038 a Reed output - AC & DC (built-in RC protection), smooth 1 N.O. 1.00 25 15 120 1.0 A 15 250 Bleeder resistor required for PLC AC switching compatibility. a 150 for SGA8180 and 470 for SGC8181. Not UL Magnet actuators (See page 310) Description Tubular 3.25 82 Proximity Sensors 2.72 69 2.13 54.1 * UL recognized (except where noted with a). Sensing distance t SGA8180 Catalog Number 0.8" (20.3) 1.3" (33) 7046 Flat bracket, center South pole 0.4" (10.1) 0.7" (17.8) 7093 Flat bracket, side South pole 0.2" (5.1) 0.2" (5.1) 7063 90 bracket South pole 0.2" (5.1) 0.2" (5.1) 7062 Block type 0.2" (5.1) 0.2" (5.1) 7099 Flexible tape - 1' long 0.1" (2.5) 0.1" (2.5) 7096 t All except SGA8180 tabulated at right. .1/2" NPT conduit entrance Figure 3 SGA8038 Dual Dimensions inches mm 306 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors SG Magnet Actuated Sensors Tubular Style SG Magnet Actuated Sensors / Tubular Style Specifications Wiring General characteristics Figure A Temperature range -40 F - 140 F (-40 C to 60 C) L1 Enclosure ratings NEMA Type 1,4,13 Vibration resistance 20G (10 to 1000Hz) L2 LOAD Figure C SGC8058 & SGC8181 Black - Com Blue - N.O. Brown - N.C. L2 L1 Shock resistance 50G for 11mS Differential Max. 75% (except SGA8179 = 1.06" max.) Repeatability Max. 0.003" Reed AC & DC SGA8180 Built in resistor (DC) SGC8181 Built in resistor (DC) Voltage drop 25 mV IxR IxR On delay (max.) 2 mS 0.75 ms 2.5 ms N.O. 3.5 ms N.C. NO LOAD Com 22-2 vinyl: SGA8038, 8180; 23-2 vinyl SGC 8181; Cable, 3' NC LOAD 16-2 SJTO: SGA8057, 8072. SO cable for SGA8179 Agency Listings except where noted (R) E 42259 CCN NKCR2 Voltage drop = IR, where I is load current and R built-in resistor. Options Suffix 5 meters (16') of cable 10 meters (33') of cable (for models with built in resistor) Vinyl L05 SJTO (8057, 8072, 8179) L05 Vinyl L10 SJTO (8057, 8072, 8179) L10 Proximity Sensors Description 307 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors SG Magnet Actuated Sensors Maintained Contact SG Magnet Actuated Sensors / Maintained Contact Maintained contact model - A highly reliable magnet actuated proximity limit switch designed to maintain contact for high speed stacker cranes, slow down and memory applications. Eliminates camming required for mechanically operated limit switches. Maintains the information even if power is down. 1.25 31 3.06 77 .94 23 Sensing face Movement of an N or S pole of a magnet actuator past the "blue dot" sensitive area within the specified range along the switch will change the contact position from open to closed. Once latched, the movement of the same magnetic pole in the opposite direction or the movement of the opposite magnetic pole in the same direction will unlatch the switch. 1.93 49 3.88 98 Features: * Housing - zinc die cast * PLC compatibility .203 dia. thru mtg holes .75 19 .69 17 1.44 36 1.75 .5" pipe tap * High transient protection * No bouncing 44 * 0.5" NPT conduit entrance .18 4 * UL recognized. * CSA certified. 3.50 88 Proximity Sensors NOTE: If during this procedure the switch closes and then opens again (pulses), reverse the polarity of the magnet and repeat above procedure. If desired direction of operation is opposite to that established above, reverse polarity of the magnet. Circuit Type .19 4 AC ratings (inductive or resistive) DC ratings (resistive only) VA (max.) Volts (nom.) Current (max.) VA (max.) Volts (max.) Current (max.) - - - 15 250 360 120 3.0 A - - Leakage (mA) Wiring Fig. Catalog Number 1.0 A 0 A SGA8018 - - 1.7 A SGO8026 - - 1.7 B SGO8110 Reed, DC 1.06 26 .203 dia. thru mtg holes 1.44 36 1 N.O. Triac, AC 1 N.O. Triac, AC low temperature: -30 F to 85 F 1 N.O. Figure 1 SGA8018 SGO8026 SGO8110 SGO8141 360 120 3.0 A Magnet actuators (see page 310) Description Sensing Distance Catalog Number Tubular 1.3" 7046 South pole 1.0" 7093 North pole 1.0" 7547 South pole 0.7" 7063 North pole 0.7" 70631 South pole 0.7" 7062 North pole 0.7" 70621 Block type 0.5" 7099 Flexible tape - 1" long 0.5" 7096 Flat bracket, center Flat bracket, side 90 bracket Dual Dimensions inches mm 308 (c)1997- 2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors SG Magnet Actuated Sensors Maintained Contact SG Magnet Actuated Sensors / Maintained Contact Specifications Wiring Mechanical Figure A L2 L1 LOAD Enclosure ratings Vibration resistance Figure B L1 2 1 6.8k L2 LOAD 3 Connect terminal 3 (heater) to line (L2) for operation below +32F. +32 F to 140 F (0 C to 60 C) Temperature range +30 F to 85 F (-35 C to 30 C) for SGO8110 NEMA Type 1, 4, 13 20 G (10 to 2000 Hz) Shock resistance 50 G @ 11 ms Differential Max. 50% Repeatability Max. 0.003" Electrical Reed Triac Voltage drop - 3V Minimum load current (mA) - 15 mA On delay mS 2 ms 2 ms Off delay mS 2 ms 2 ms Cable - screw terminals #16 AWG Agency Listings E 42259 CCN NKCR2 LR 25490 Class 3211 03 Proximity Sensors (R) 309 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors SG Magnet Actuated Sensors Magnet Actuators SG Magnet Actuated Sensors / Magnet Actuators Features: * Industrial grade magnet recommended for magnet actuated proximity sensors. * Alnico is used as magnet material for all rigid models. 7046 * Kevlar is used for the flexible magnetic tape. * The rigid models are already mounted on several types of standard brackets for convenience (except the tubular "high power" version). * Both South and North Poles are accessible and marked. The South Pole version is the standard. North Pole versions may be required in conjunction with the maintained magnetic switch (see page 308). 7093 * For comparison an average magnetic strength rating is listed below. Measurements were made with a Gaussmeter at 0.13" from the sensing surface. Description Magnetic Strength Catalog Number Tubular 700 Gauss 7046 South pole 330 Gauss 7093 North pole 330 Gauss 7547 South pole 240 Gauss 7063 North pole 240 Gauss 70631 South pole 260 Gauss 7062 North pole 260 Gauss 70621 340 Gauss 7099 180 Gauss 7096t Flat bracket, center Flat bracket, side 7063 Proximity Sensors 90 bracket Block type Flexible tape t 1' long For longer tape specify total length in feet. Example: 70966 = 6 feet. 7062 7099 7096 310 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors SG Magnet Actuated Sensors Magnet Actuators SG Magnet Actuated Sensors / Magnet Actuators Magnet actuator dimensions Tubular magnet actuator 7046 Magnet actuator 7093 (south pole) Magnet actuator 7597 (north pole) .12 3 3.25 82 N .34 8 S S S S 4 holes .18" dia 2.56 65 .62 15 3.0 76 .50 12 .50 12 .31 7 1.00 25 Magnet actuator 7062 (south pole) Magnet actuator 70621 (north pole) 1.50 38 1.50 38 2 holes .266" dia. .75 19 .12 3 .50 12 2.37 60 3.37 85 3.75 95 2 holes .266" dia. .37 9 .37 9 .75 19 Proximity Sensors Magnetic actuator 7063 (south pole) Magnet actuator 70631 (north pole) .87 22 .50 12 Block type magnet actuator 7099 Flexible magnetic tape 7096 1 foot 1' standard length .75 19 .87 17 1.25 31 2 holes thru .18" dia. 1.00 25 .31 7 .50 12 Ainico magnet .43 10 .62 15 1.00 25 1.75 44 .18 4 Dual Dimensions inches mm 311 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors ST Grounded Probe Switch 1.0312" ST Grounded Probe Switch .2812" The touch switch is a highly reliable AC solid state presence sensor designed for precise conductivity sensing. Applications include high temperature environment, light conductive, aggressive mechanical and chemical environments that targets positive end-point sensing. All models have a visible neon pilot light to indicate operation of the switch. Features * Housings - zinc die cast * Solid state - no moving parts 2 - .203" dia. mtg holes 2.343" * 115 Vac completely self-contained * Probes up to 10 feet long * High current output - no relay required for most applications * Fast response - no warm-up time 10-32 x .375" deep mtg holes tapped from back * 0.5" NPT conduit entrance * UL Recognized Operation The switch is actuated when a conductive path between probe terminal and ground (1 M or less) is established. The electrical contact to ground operates the switching thyristor. Internal RC snubber and varistor provide effective protection from typical transients. Normal open models have a 10 millisecond (maximum) turn on time. Different off delay times are offered in order that the design engineer may compensate for relay chatter when the probe is subjected to "bounce" from irregular contact with the grounded metal point of contact. 1.1562" Proximity Sensors 1.625" 8-32 probe terminal NOTE: For isolated circuits where the ground is not common - the switch ground terminal should be connected to the neutral. The metal target to be detected by the probe should then be wired also to the neutral. .2812" Probe characteristics The probe terminal is an 8-32 stud protruding from the center of the head. Extensions may be any electrically conductive wire or material suitably insulated from grounded surface and limited in length to 10 feet or less. 2.343" * Open voltage: 12 Vdc * Peak current: 1 mA Switch models Circuit type Voltage (nominal) Current load (max.) Leakage current (max.) On delay Off delay Catalog Number Terminal screws .375" .8437" 1.75" N.O. 120 Vac 3 Amp 1.7 mA 10 ms 100 ms STO8164 N.C. 120 Vac 3 Amp 1.7 mA 100 ms 30m s ST18165 N.O. 120 Vac 3 Amp 1.7 mA 10 ms 400 ms STO8166 N.O. 120 Vac 3 Amp 1.7 mA 10 ms 20 ms STO8167 Pre wired with 3 feet of cable N.O. 120 Vac 3 Amp 1.7 mA 10 ms 100 ms STO8001 N.C. 120 Vac 3 Amp 1.7 mA 100 ms 30 ms ST18002 N.O. 120 Vac 3 Amp 1.7 mA 10 ms 400 ms STO8036 N.O. 120 Vac 3 Amp 1.7 mA 10 ms 20 ms STO8042 312 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors ST Grounded Probe Switch ST Grounded Probe Switch Specifications Wiring General characteristics Cable wiring Temperature range Enclosure ratings L1 Blk Gnd Wht Red L2 LOAD hot neutral Target connected to ground Voltage drop -40 F to 158 F (-40 C to 70 C) NEMA Type 1, 4, 13 2V Inrush current maximum 10 Amp Minimum load current 15 mA Power supply current (no load) 30 mA Cable 3' 16-4 SJTO or terminal screws #16 AWG Terminal strip wiring 1 L1 hot housing 2 3 Not used 4 L2 LOAD neutral Target connected to ground Housing must be grounded for proper operation. Proximity Sensors Model ST switches may be wired in series or parallel. Connect red lead to black lead of other switch (terminal 4 to terminal 1 of other switch) for series operation. The voltage drop across each switch (in the closed state) does not exceed 2 volts AC. 313 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS7V Magnetic Cylinder Position Sensors Rectangular, Compact; DC XS7V Magnetic Cylinder Position Sensors / Rectangular, Compact; DC Description Detects the magnet installed on the piston through a non-ferrous cylinder wall. Universal mounting provided by clamp style and strap style mounting. Fast troubleshooting aided by output LED. Trouble-free operation insured by extensive protective circuitry. Connector versions. Circuit type Nominal Sensing Range t Output mode Load current maximum Voltage maximum Mating Catalog connector style Number 2m Cable PNP 3.5 mm N.O. 100 mA 10-30 Vdc - XS7V12PA332 NPN 3.5 mm N.O. 100 mA 10-30 Vdc - XS7V12NA332 Connector - Nano style Cable PNP 3.5 mm N.O. 100 mA 10-30 Vdc 1 thru 8 XS7V12PA332S NPN 3.5 mm N.O. 100 mA 10-30 Vdc 1 thru 8 XS7V12NA332S t At 11mT. Application Information The XS7V sensors detect the magnetic field generated by a magnet. The sensors are mounted in general on the cylinder. The magnets are mounted on the end of the piston and influence the sensor through a non- ferrous cylinder wall (i.e. aluminum). The sensors can be mounted anywhere along the cylinder using mounting accessories such as the ones shown on the next page. Proximity Sensors Cylinder Diameter IN Nano style connector Dual Dimensions inches mm Active Travel CA1 mm Travel C1 Hysteresis H IN mm IN mm IN mm 0.39 10 0.28 7.2 0.13 3.25 0.028 0.70 0.47 12 0.31 7.8 0.14 3.45 0.028 0.70 0.63 16 0.33 8.5 0.15 3.80 0.035 0.90 0.79 20 0.37 9.3 0.17 4.20 0.035 0.90 0.98 25 0.40 10.2 0.18 4.60 0.039 1.00 1.26 32 0.43 11 0.20 5.00 0.039 1.00 1.57 40 0.47 12 0.22 5.50 0.039 1.00 1.97 50 0.47 12 0.22 5.50 0.039 1.00 2.48 63 0.55 14 0.26 6.50 0.039 1.00 3.15 80 0.63 16 0.30 7.50 0.039 1.00 3.94 100 0.71 18 0.33 8.50 0.039 1.00 314 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors XS7V Magnetic Cylinder Position Sensors Rectangular, Compact; DC XS7V Magnetic Cylinder Position Sensors / Rectangular, COmpact; DC Specifications Wiring Mechanical 3 wire, PNP + BN/1 PNP Sensing range @ 11 mT BK/4 (NO) Enclosure rating - BU/3 3 wire, NPN + BN/1 NPN BK/4 (NO) BU/3 Standard Temperature range - 0 to 3.5mm Operating -10 C to 60 C (+ 14 F to + 140 F) Storage -40 C to + 70 C (-40 F to + 158 F) NEMA Type IEC Type IP67 Enclosure material Plastic Repeatability 0.1 mm Electrical Voltage range 12 to 24 Vdc Voltage limit (including ripple) 10 to 30 Vdc Voltage drop (across switch), closed state 0.5 V Maximum load current 100 mA Current consumption (no load) 30m A Actuation speed (max.) 10 ms Response time 3 ms Options Suffix Extended cable length 5 meter cable L1 10 meter cable L2 Accessories Stainless Steel Mounting Collar Description Cylinder Diameter mm/in Catalog Number Sold in Lots of Stainless steel mounting collar 10 / 0.39 XSZB210 5 Stainless steel mounting collar 12 / 0.47 XSZB212 5 Stainless steel mounting collar 16 / 0.63 XSZB216 5 Stainless steel mounting collar 20 / 0.79 XSZB220 5 Stainless steel mounting collar 25 / 0.98 XSZB225 5 Mounting bracket (for cylinder rods) 32 / 1.26 to 40 / 1.57 XSZB240 1 Mounting bracket (for cylinder rods) 50 / 1.97 to 63 / 2.48 XSZB263 1 Mounting bracket (for cylinder rods) 80 / 3.15 to 100 / 3.94 XSZB200 1 Mounting Bracket for Cylinder Rods 315 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Description Proximity Sensors Inductive Sensor Accessories Conduit Adapters for Tubular Sensors Inductive Sensor Accessories / Conduit Adapters for Tubular Sensors Features: * Available for 12, 18 and 30mm tubular sensors * 1/2" - 14 NPT Inside Thread * Nickel Plated Brass Proximity Sensors Tube Diameter Tube Thread Size 12mm (0.47) M12 x 1 XSZCAR12 18mm (0.71) M18 x 1 XSZCAR18 30mm (1.18) M30 x 1.5 XSZCAR30 Dimensions (mm) Catalog Number 316 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Inductive Sensor Accessories Face caps for Tubular Proximity Sensors Inductive Sensor Accessories / Face Caps for Tubular Proximity Sensors Features: * Shielded and non-shielded caps available * Different versions available (beveled or non-beveled) * Provides sensor face protection with no effect in operation Description Protection in harsh applications, helps to prevent abrasions, cracks, and other possible damage to the sensors face. Available in many different materials Ceramic, Delrin (Acetal), and Teflon. Provide your sensor with protection and a longer life without the additional charge of a stainless steel face option. Beveled caps (30 chamfer) A A 30 D C D E Catalog Number 5.1 (0.20) 15.1 (0.59) 0.38 (0.15) 7.00 (0.28) - XSZEN08 0.76 (0.03) 12.2 (0.48) - XSZEN12 0.76 (0.03) 17.0 (0.67) - XSZEN18 1.01 (0.04) 29.0 (1.19) - XSZEN30 0.38 (0.15) 7.00 (2.76) 9.60 (0.37) XSZENN08 0.76 (0.03) 12.9 (0.51) 17.3 (0.68) XSZENN12 0.76 (0.03) 16.6 (0.65) 17.8 (0.70) XSZENN18 1.01 (0.04) 30.0 (1.18) 22.8 (0.90) XSZENN30 12 mm Diameter shielded 6.2 (0.26) C XSZENkk 24.1 (0.95) 18 mm Diameter shielded 8.2 (0.32) 31.2 (1.23) Proximity Sensors B o B 8 mm Diameter shielded 30 mm Diameter shielded 7.6 (0.30) o A 44.5 (1.75) 8 mm Diameter non-shielded E 5.1 (0.20) 30 14.1 (0.56) 12 mm Diameter non-shielded 6.5 (0.26) D B 22.9 (0.90) 18 mm Diameter non-shielded C XSZENNkk 8.2 (0.32) 34.0 (1.34) 30 mm Diameter non-shielded 7.5 (0.30) 44.5 (1.75) Non-beveled caps A A B C Catalog Number 8.90 (0.35) 16.1 (0.63) 1.26 (0.05) XSZSC12C 8.90 (0.35) 16.1 (0.63) 0.76 (0.03) XSZSC12D 8.90 (0.35) 16.1 (0.63) 0.76 (0.03) XSZSC12T 12 mm Diameter shielded B C XSZSCkkkk 12 mm Diameter non-shielded 15.2 (0.60) 16.1 (0.63) 0.76 (0.03) XSZSC12ND 15.2 (0.60) 16.1 (0.63) 0.76 (0.03) XSZSC12NT 8.80 (0.35) 24.4 (0.96) 1.27 (0.05) XSZSC18D 8.80 (0.35) 24.4 (0.96) 1.27 (0.05) XSZSC18T 18 mm Diameter shielded 18 mm Diameter non-shielded 18.0 (0.59) 24.4 (0.96) 1.27 (0.05) XSZSC18ND 18.0 (0.59) 24.4 (0.96) 1.27 (0.05) XSZSC18NT Dual Dimensions inches mm 317 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Inductive Sensor Accessories Plunger Screw Adapters Inductive Sensor Accessories / Plunger Screw Adapters Features * Accepts 8, 12, or 18mm shielded sensor * Heat-treated alloy steel construction * Rugged stop with solid state output Description Plunger Screw Adapters provide the ability for a shielded inductive proximity sensor to be used as a mechanical stop switch. Helps to solve many applications that require precise end of travel signals, or a hard stop. Spring requires 252g (9oz) to actuate sensor. A B C D E (Dia.) F G Impact Force (Max.) Catalog Number 8 mm Diameter Shielded Sensors M8x1 25.0 (1.00) M8x1 3.16 (0.12) 5.84 (0.23) 6.26 (0.24) 11.0 (0.43) 2000 N (450 lb-ft) XSZB0825 M8x1 50.0 (2.00) M8x1 3.16 (0.12) 5.84 (0.23) 6.26 (0.24) 11.0 (0.43) 2000 N (450 lb-ft) XSZB0850 12 mm Diameter Shielded Sensors Proximity Sensors M12x1 25.0 (1.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1225 M12x1 50.0 (2.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1250 M12x1 75.0 (3.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1275 M12x1 100 (4.00) M12x1 4.32 (0.17) 9.40 (0.37) 4.22 (0.17) 15.7 (0.62) 20,500 N (4608 lb-ft) XSZB1210 18 mm Diameter Shielded Sensors M18x1 25.0 (1.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1825 M18x1 50.0 (2.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1850 M18x1 75.0 (3.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1875 M18x1 100 (4.00) M18x1 4.32 (0.17) 14.2 (0.56) 4.22 (0.17) 22.1 (0.87) 45,000 N (10,115lbft) XSZB1810 31.8 (1.25) B D G C E F A 16.7 (0.66) XSZBkkkk 318 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Inductive Sensor Accessories Proximity Probe Adapters Inductive Sensor Accessories / Proximity Probe Adapters Features: * Accepts any 8 or 12mm shielded sensor * Accurate and compact switching in confined areas * Large variety of stand probe lengths and diameters Description Proximity Probe is a spring loaded actuator designed to work with 8mm or 12mm cylindrical inductive proximity sensors. The probe and sensor combination offers increased flexibility in applications that require tight positioning. A B C D E (Dia.) F Catalog Number 8 mm Diameter Shielded Sensor 75.6 (2.98) 25.0 (1.00) M8 x 1 to depth of M8 x 1 21.8 (0.86) 3.18 (.125) 11.1 (.436) XSZPP0825 99.6 (3.92) 50.0 (2.00) M8 x 1 to depth of M8 x 1 21.8 (0.86) 3.18 (.125) 11.1 (.436) XSZPP0850 126 (4.96) 75.0 (3.00) M8 x 1 to depth of M8 x 1 21.8 (0.86) 3.18 (.125) 11.1 (.436) XSZPP0875 150 (5.91) 100 (4.00) M8 x 1 to depth of M8 x 1 21.8 (0.86) 3.18 (.125) 11.1 (.436) XSZPP0810 75.6 (2.98) 25.0(1.00) M12 x 1 to depth of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1225 99.6 (3.92) 50.0 (2.00) M12 x 1 to depth of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1250 126 (4.96) 75.0 (3.00) M12 x 1 to depth of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1275 150 (5.91) 100 (4.00) M12 x 1 to depth of 18.0 (0.71) M12 x 1 6.35 (0.25) 15.8 (.623) XSZPP1210 Proximity Sensors 12 mm Diameter Shielded Sensor A 17.4 (.685) B Probe travel C E D 3.90 (0.15) F XSZPPkkkk 319 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Inductive Sensor Accessories Quick Change Mounting Tube Inductive Sensor Accessories / Quick Change Mounting Tube Features: * Quick change mounting available for 8,12,18 and 30mm sensors * Short and Long barrel lengths available * One time adjustment, makes sensor replacement easy and quick * Provide protection to sensor from impact and damage * Teflon caps available for quick change mounts (shown below) Description Provides time savings in maintenance of sensors, helps prevent downtime. An internal shoulder stop and a collet-style locknut precisely holds the sensor. This helps to maintain a precise sensing distance and reduces the required expertise needed during sensor installation. A B C D E F Catalog Number 8 mm Diameter Shielded Sensors 8.18 (0.32) 32.4 (1.28) 17.5 (0.69) M12x1 3.85 (0.15) 16.9 (0.67) XSZQT08 8.18 (0.32) 48.0 (1.90) 34.0 (1.34) M12x1 3.85 (0.15) 16.9 (0.67) XSZQTL08 12 mm Diameter Shielded Sensors Proximity Sensors 12.1 (0.48) 33.7 (1.34) 19.5 (0.77) M16.5x1.5 4.01 (0.16) 21.8 (0.86) XSZQT12 12.1 (0.48) 44.8 (1.76) 30.0 (1.18) M16.5x1.5 4.01 (0.16) 21.8 (0.86) XSZQTL12 18 mm Diameter Shielded Sensor 18.1 (0.71) 38.5 (1.52) 20.0 (0.79) M24 x 1.5 4.95 (0.19) 30.0 (1.18) XSZQT18 18.1 (0.71) 58.0 (2.28) 40.0 (1.57) M24 x 1.5 4.95 (0.19) 30.0 (1.18) XSZQTL18 30 mm Diameter Shielded Sensors 30.1 (1.19) 35.0 (1.50) 20.0 (0.79) M36 x 1.5 6.13 (0.24) 41.0 (1.61) XSZQT30 30.1 (1.19) 58.0 (2.28 40.0 (1.57) M36 x 1.5 6.13 (0.24) 41.0 (1.61) XSZQTL30 B A C F D E XSZQTkkk Teflon Caps for Quick change mounting tubes A B C D Catalog Number 8.84 (0.35) 14.8 (0.59) 0.76 (0.03) M12x1 XSZQTC08 7.24 (0.29) 19.9 (0.75) 0.76 (0.03 M16x1 XSZQTC12 9.00 (0.35) 28.7 (1.13) 0.76 (0.03 M24x1.5 XSZQTC18 9.00 (0.35) 41.4 (1.63) 1.26 (0.05) M36x1.5 XSZQTC30 A D B C XSZQTCkk 320 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Inductive Sensor Accessories Spring-loaded Tubular Sensor Mount Inductive Sensor Accessories / Spring-loaded Tubular Sensor Mount Features: * Accepts 8, 12, 18 & 30mm shielded or non-shielded sensors * Sensors become unaffected by accidental impact * Shielded and Non-shielded caps available, see page 313. Description Spring loaded sensor mount for tubular body styles provides impact protection for the sensor in the case of target over travel. The mount is designed to be threaded onto a tubular sensor and held in place by using one of the mounting nuts provided with the sensor. Caps are available to help protect the face of the sensor from lateral and axial impacts, see page 313. A Inside Thread B Outside Thread C Maximum E D Maximum Across Flats Over travel F G Catalog Number 12.2 (.481) 22.2 (.875) 22.0 (.867) 3.10 (.155) XSZSN08 8 mm Diameter Sensors M8 x 1 M16 x 1.5 9.22 (.363) 12 mm Diameter Sensors M12 x 1 M18 x 1 10.0 (.394) 23.9 (.943) 12.1 (.476) 21.3 (.840) 3.94 (.156) XSZSN12LP M12 x 1 M22 x 1.5 11.5 (.454) 28.4 (1.12) 10.5 (.413) 22.1 (.871) 3.88 (.153) XSZSN12 16.1 (.634) 34.8 (1.37) 13.3 (.523) 29.7 (1.17) 5.08 (0.20) XSZSN18 24.6 (.972) 50.8 (2.00) 15.6 (.615) 37.0 (1.37) 4.98 (.196) XSZSN30 M18 x 1 M30 x 1.5 Proximity Sensors 18 mm Diameter Sensors 30 mm Diameter Sensors M30 x 1.5 M47 x 1.5 F C A D E G B XSZSNkk 321 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Flat Inductive Sensing Curves Flat Inductive Sensing Curves Shielded Sn (mm) 3 2,5 2 XS7J1A1D 1,5 Target size Usable range mm mm 5x5x1 0...2 ________ pick up points - - - - - - - - drop out points 1 0,5 mm -4 -3 -2 -1 0 1 2 3 4 mm Sn (mm) 6 5 4 XS7F1A1D 3 Target size Usable range mm mm 5x5x1 0...4 ________ pick up points - - - - - - - - drop out points 2 Proximity Sensors 1 mm -8 -6 -4 -2 0 2 4 6 8 mm Sn (mm) 12 Target size Usable range mm mm XS7E1A1D 8x8x1 0...8 XS7E1A1C 8x8x1 0...8 10 8 6 ________ pick up points - - - - - - - - drop out points 4 2 mm-10 -5 0 5 10 mm Sn (mm) 16 14 12 2 Target size Usable range mm mm 10 XS7C1A1D 18 x 18 x 1 0 . . . 12 8 XS7C1A1C 18 x 18 x 1 0 . . . 12 6 ________ pick up points - - - - - - - - drop out points 4 2 mm -15 -10 -5 0 5 10 15 20 mm Sn (mm) 45 40 Target size Usable range mm mm XS7D1A1D 30 x 30 x 1 0 . . . 32 XS7D1A1C 30 x 30 x 1 0 . . . 32 35 30 25 20 15 ________ pick up points - - - - - - - - drop out points 10 5 mm -40 -30 -20 -10 0 10 20 30 40mm 322 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Tubular Inductive Sensing Curves Tubular Inductive Sensing Curves Shielded Sn (mm) 1 o 4 XS1 o 5 (M5x0.5) XS1 3 2 2 o 6.5 XS1 o 8 (M8x1) XS1, XS3 2 1 1 1 4 3 2 Usable range mm mm 4 5x5x1 0 . . . 0.8 5 5x5x1 0 . . . 0.8 6.5 8x8x1 0 . . . 1.2 0 1 8 8x8x1 0 . . . 1.2 12 12 x 12 x 1 0 . . . 1.6 ________ pick up points - - - - - - - - drop out points 0.5 mm 6 Size 3 2 3 o 12 (M12x1) XS1, XS3 Standard targets 1 2 6 mm 4 3 Sn (mm) 2 2 o 30 (M30x1.5) XS1, XS3 2 10 8 1 Size Usable range mm mm 18 18 x 18 x 1 0...4 30 30 x 30 x 1 0...8 ________ pick up points - - - - - - - - drop out points 1 5 Standard targets Proximity Sensors 15 1 o 18 (M18x1) XS1, XS3 2.5 mm15 10 7.5 5 0 2.5 2.5 5 15 mm 10 7.5 Non-Shielded and Extended Range Sn (mm) 4 1 o 8 (M8x1) XS1, XS2, XS4 2 2 2 o 12 (M12x1) XS1, XS2, XS4 Size Usable range mm mm 8 8x8x1 0...2 12 12 x 12 x 1 0 . . . 3.2 ________ pick up points - - - - - - - - drop out points 2 1 1 Standard targets 1 0.5 mm 6 4 3 2 0 1 1 2 6 mm 4 3 Sn (mm) 15 1 o 18 (M18x1) XS1, XS2, XS4 2 2 o 30 (M30x1.5) XS1, XS2, XS4 2 10 1 1 Standard targets Size Usable range mm mm 18 24 x 24 x 1 0 . . . 6.4 30 45 x 45 x 1 0 . . . 12 ________ pick up points - - - - - - - - drop out points 8 5 2.5 mm 15 10 7.5 5 2.5 0 2.5 5 7.5 10 15 mm 323 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Block Type Inductive Sensing Curves Block Type Inductive Sensing Curves Sn (mm) 1 shielded, XSEC10 1 1 10 2 shielded, XSG*02 3 non-shielded, XSG*04 5 3 2 2 mm 15 10 5 Size Usable range mm mm XSEC10 30 x 30 x 1 0...8 XSG*02 12 x 12 x 1 0 . . . 1.6 XSG*04 12 x 12 x 1 0 . . . 3.2 ________ pick up points - - - - - - - - drop out points 3 4 Standard targets 2 0 5 10 15 mm Sn (mm) 1 XSB*10 2 2 25 2 XSB*25 20 Proximity Sensors 1 13 20 0 10 Size Usable range mm mm XSB*10 40 x 40 x 1 0...9 XSB*25 75 x 75 x 1 0 . . . 20 ________ pick up points - - - - - - - - drop out points 1 10 mm 30 Standard targets 10 20 30 mm Sn (mm) 60 1 shielded, XS7 2 non-shielded, XS8 2 Standard targets Size Usable range mm mm XSC/XS7 45 x 45 x 1 0 . . . 12 XSC/XS8 60 x 60 x 1 0 . . . 16 2 20 1 1 15 ________ pick up points - - - - - - - - drop out points 10 mm 30 20 0 10 10 20 30 mm Sn (mm) 1 fixed sensing distance, XSD*40 60 2 2 adjustable sensing distance, XSD*60 2 40 1 2 1 Size Usable range mm mm XSD*40 120 x 120 x 1 0 . . . 32 XSD*60 180 x 180 x 1 0 . . . 48 ________ pick up points - - - - - - - - drop out points 2 30 Standard targets 20 mm 40 20 0 20 40 mm 324 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Existing to New Substitution Existing to New Substitution 8 mm Cylindrical XS1M08DA210 $ New Design XS508B1DAL2 Old Design New Design Old Design XS1N08PA349L2 XS608B1PAL10 XS1M12KP340D New Design XS508B1NBM8 XS1N08PA349S XS608B1PAM12 XS1M12KP340L1 XS508B1PAL5 XS1M08DA210D XS508B1DAM12 XS1N08PB340 XS508B1PBL2 XS1M12KP340L1 XS508B1PBL5 XS1M08DA210L1 XS508B1DAL5 XS1N08PB340D XS508B1PBM8 XS1M12KP340L1 XS508B1NAL5 XS1M08DA210L2 XS508B1DAL10 XS1N08PB340L1 XS508B1PBL5 XS1M12KP340L1 XS508B1NBL5 XS1M08DA210LD XS508B1DAL08M12 XS1N08PB340S XS508B1PBM8 XS1M12KP340L2 XS508B1PAL10 XS1M08DB210 XS508B1DBL2 XS1N08PB349 XS608B1PBL2 XS1M12KP340L2 XS508B1PBL10 XS1M08DB210D XS508B1DBM12 XS1N08PB349D XS608B1PBM12 XS1M12KP340L2 XS508B1NAL10 XS1M08DB210L1 XS508B1DBL5 XS1N08PB349L1 XS608B1PBL5 XS1M12KP340L2 XS508B1NBL10 XS1M08NA370 XS608B1NAL2 XS1N08PB349L2 XS608B1PBL10 XS1M12NA370 XS612B1NAL2 XS1M08NA370D XS608B1NAM12 XS1N08PB349S XS608B1PBM12 XS1M12NA370D XS612B1NAM12 XS1M08NA370L1 XS608B1NAL5 XS2M08NA340 XS608B1NAL2 XS1M12NA370L1 XS612B1NAL5 XS1M08NB370 XS608B1NBL2 XS2M08NC410 XS608B1NAL2 XS1M12NA370L2 XS612B1NAL10 XS1M08NB370D XS608B1NBM12 XS2M08NC410 XS608B1NBL2 XS1M12NA370S XS612B1NAM12 XS1M08NC410 XS508B1NAL2 XS2M08NC410D XS608B1NAM12 XS1M12NB370 XS612B1NBL2 XS1M08NC410 XS508B1NBL2 XS2M08NC410D XS608B1NBM12 XS1M12NB370D XS612B1NBM12 XS1M08NC410D XS508B1NAM8 XS2M08PC410 XS608B1PAL2 XS1M12PA370 XS612B1PAL2 XS1M08NC410D XS508B1NBM8 XS2M08PC410 XS608B1PBL2 XS1M12PA370D XS612B1PAM12 XS1M08PA370 XS608B1PAL2 XS2M08PC410D XS608B1PAM12 XS1M12PA370L1 XS612B1PAL5 XS1M08PA370D XS608B1PAM12 XS2M08PC410D XS608B1PBM12 XS1M12PA370L2 XS612B1PAL10 XS1M08PA370L1 XS608B1PAL5 XS2N08NA340 XS608B1NAL2 XS1M12PB370 XS612B1PBL2 XS1M08PA370L2 XS608B1PAL10 XS2N08NA340D XS608B1NAM8 XS1M12PB370D XS612B1PBM12 XS1M08PA370LD XS608B1PAL08M12 XS2N08NA340L1 XS608B1NAL5 XS1M12PB370L1 XS612B1PBL5 XS1M08PA370S XS608B1PAM12 XS2N08NA340S XS608B1NAM8 XS1N12NA340 XS512B1NAL2 XS1M08PB370 XS608B1PBL2 XS2N08NB340 XS608B1NBL2 XS1N12NA340D XS512B1NAM12 XS1M08PB370D XS608B1PBM12 XS2N08PA340 XS608B1PAL2 XS1N12NA340L1 XS512B1NAL5 XS1M08PB370L1 XS608B1PBL5 XS2N08PA340D XS608B1PAM8 XS1N12NA349 XS612B1NAL2 XS1M08PB370L2 XS608B1PBL10 XS2N08PA340L1 XS608B1PAL5 XS1N12NA349D XS612B1NAM12 XS1M08PC410 XS508B1PAL2 XS2N08PA340L2 XS608B1PAL10 XS1N12NA349L1 XS612B1NAL5 XS1M08PC410 XS508B1PBL2 XS2N08PA340S XS608B1PAM8 XS1N12NA349L2 XS612B1NAL10 XS1M08PC410D XS508B1PAM8 XS2N08PB340 XS608B1PBL2 XS1N12NB340 XS512B1NBL2 XS1M08PC410D XS508B1PBM8 XS2N08PB340D XS608B1PBM8 XS1N12NB340D XS512B1NBM12 XS1N08NA340D XS508B1NAM8 XS2N08PB340S XS608B1PBM8 XS1N12NB349 XS612B1NBL2 XS1N08NA340L1 XS508B1NAL5 XS3P08NA340 XS508B1NAL2 XS1N12NB349D XS612B1NBM12 XS1N08NA340L2 XS508B1NAL10 XS3P08NA340D XS508B1NAM8 XS1N12NB349L2 XS612B1NBL10 XS1N08NA340S XS508B1NAM8 XS3P08NA370 XS608B1NAL2 XS1N12NC410 XS512B1NAL2 XS1N08NA349 XS608B1NAL2 XS3P08PA340 XS508B1PAL2 XS1N12NC410 XS512B1NBL2 XS1N08NA349D XS608B1NAM12 XS3P08PA340D XS508B1PAM12 XS1N12NC410D XS512B1NBM12 XS1N08NA349L1 XS608B1NAL5 XS3P08PA340L1 XS508B1PAL5 XS1N12NC410D XS512B1NAM12 XS1N08NA349S XS608B1NAM12 XS3P08PA370 XS608B1PAL2 XS1N12NC410L1 XS512B1NAL5 XS1N08NB340 XS508B1NBL2 12 mm Cylindrical XS1N12NC410L1 XS512B1NBL5 XS1N08NB340D XS508B1NBM8 XS1M12DA210 XS512B1DAL2 XS1N12PA340 XS512B1PAL2 $ XS1N08NB340S XS508B1NBM8 XS1M12DA210D XS512B1DAM12 XS1N12PA340D XS512B1PAM12 XS1N08NB349 XS608B1NBL2 XS1M12DA210L1 XS512B1DAL5 XS1N12PA340L1 XS512B1PAL5 XS1N08NB349D XS608B1NBM12 XS1M12DA210L2 XS512B1DAL10 XS1N12PA340L2 XS512B1PAL10 XS1N08NB349S XS608B1NBM12 XS1M12DB210 XS512B1DBL2 XS1N12PA340S XS512B1PAM12 XS1N08PA340 XS508B1PAL2 XS1M12DB210D XS512B1DBM12 XS1N12PA349 XS612B1PAL2 XS1N08PA340D XS508B1PAM8 XS1M12DB210L1 XS512B1DBL5 XS1N12PA349D XS612B1PAM12 XS1N08PA340L1 XS508B1PAL5 XS1M12KP340 XS508B1PAL2 XS1N12PA349L1 XS612B1PAL5 XS1N08PA340L2 XS508B1PAL10 XS1M12KP340 XS508B1PBL2 XS1N12PA349L2 XS612B1PAL10 XS1N08PA340LD XS508B1PAL08M12 XS1M12KP340 XS508B1NAL2 XS1N12PA349S XS612B1PAM12 XS1N08PA340S XS508B1PAM8 XS1M12KP340 XS508B1NBL2 XS1N12PB340 XS512B1PBL2 XS1N08PA349 XS608B1PAL2 XS1M12KP340D XS508B1PAM8 XS1N12PB340D XS512B1PBM12 XS1N08PA349D XS608B1PAM12 XS1M12KP340D XS508B1PBM8 XS1N12PB349 XS612B1PBL2 XS1N08PA349L1 XS608B1PAL5 XS1M12KP340D XS508B1NAM8 XS1N12PB349D XS612B1PBM12 Proximity Sensors Old Design 325 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Existing to New Substitution Existing to New Substitution Proximity Sensors Old Design New Design Old Design New Design Old Design New Design XS1N12PB349L1 XS612B1PBL5 XS2N12PA340 XS612B1PAL2 XS1M18NA370C XS618B1NAM12 XS1N12PB349L2 XS612B1PBL10 XS2N12PA340D XS612B1PAM12 XS1M18NA370D XS618B1NAM12 XS1N12PB349S XS612B1PBM12 XS2N12PA340L1 XS612B1PAL5 XS1M18NA370L1 XS618B1NAL5 XS1N12PC410 XS512B1PAL2 XS2N12PA340L2 XS612B1PAL10 XS1M18NA370L2 XS618B1NAL10 XS1N12PC410 XS512B1PBL2 XS2N12PB340 XS612B1PBL2 XS1M18NB370 XS618B1NBL2 XS1N12PC410D XS512B1PAM12 XS2N12PB340D XS612B1PBM12 XS1M18NB370C XS618B1NBM12 XS1N12PC410D XS512B1PBM12 XS2N12PC410 XS612B1PAL2 XS1M18NB370D XS618B1NBM12 XS1N12PC410L1 XS512B1PAL5 XS2N12PC410 XS612B1PBL2 XS1M18NB370L1 XS618B1NBL5 XS1N12PC410L1 XS512B1PBL5 XS2N12PC410D XS612B1PAM12 XS1M18NB370L2 XS618B1NBL10 XS1N12PC410L2 XS512B1PAL10 XS2N12PC410D XS612B1PBM12 XS1M18PA370 XS618B1PAL2 XS1N12PC410L2 XS512B1PBL10 XS2N12PC410L1 XS612B1PAL5 XS1M18PA370A XS618B1PAM12 XS1N12PC419D XS612B1PAM12 XS2N12PC410L1 XS612B1PBL5 XS1M18PA370B XS618B1PAM12 XS1N12PC419D XS612B1PBM12 XS2N12PC410L2 XS612B1PAL10 XS1M18PA370C XS618B1PAM12 XS2M12KP340 XS612B1PAL2 XS2N12PC410L2 XS612B1PBL10 XS1M18PA370D XS618B1PAM12 XS2M12KP340 XS612B1PBL2 XS3P12NA340 XS512B1NAL2 XS1M18PA370E XS618B1PAM12 XS2M12KP340 XS612B1NAL2 XS3P12NA340D XS512B1NAM12 XS1M18PA370G XS618B1PAM12 XS2M12KP340 XS612B1NBL2 XS3P12NA370 XS612B1NAL2 XS1M18PA370L1 XS618B1PAL5 XS2M12KP340D XS612B1PAM12 XS3P12PA340 XS512B1PAL2 XS1M18PA370L2 XS618B1PAL10 XS2M12KP340D XS612B1PBM12 XS3P12PA340D XS512B1PAM12 XS1M18PA370T XS618B1PAL2T XS2M12KP340D XS612B1NAM12 XS3P12PA340L1 XS512B1PAL5 XS1M18PB370 XS618B1PBL2 XS2M12KP340D XS612B1NBM12 XS3P12PA370 XS612B1PAL2 XS1M18PB370A XS618B1PBM12 XS2M12KP340L1 XS612B1PAL5 XS3P12PA370L1 XS612B1PAL5 XS1M18PB370B XS618B1PBM12 XS2M12KP340L1 XS612B1PBL5 18 mm Cylindrical XS1M18PB370C XS618B1PBM12 XS2M12KP340L1 XS612B1NAL5 XS1M18DA210 XS518B1DAL2 XS1M18PB370D XS618B1PBM12 XS2M12KP340L1 XS612B1NBL5 XS1M18DA210B XS518B1DAM12 XS1M18PB370G XS618B1PBM12 XS2M12KP340L2 XS612B1PAL10 XS1M18DA210C XS518B1DAM12 XS1M18PB370L1 XS618B1PAL5 XS2M12KP340L2 XS612B1PBL10 XS1M18DA210D XS518B1DAM12 XS1M18PB370L2 XS618B1PAL10 XS2M12KP340L2 XS612B1NAL10 XS1M18DA210G XS518B1DAM12 XS1N18NA340 XS518B1NAL2 XS2M12KP340L2 XS612B1NBL10 XS1M18DA210L1 XS518B1DAL5 XS1N18NA340D XS518B1NAM12 XS2M12NA370 XS612B1NAL2 XS1M18DA210L2 XS518B1DAL10 XS1N18NA340L1 XS518B1NAL5 XS2M12NA370D XS612B1NAM12 XS1M18DA210LD XS518B1DAL08M12 XS1N18NA340L2 XS618B1NAL10 XS2M12NA370L1 XS612B1NAL5 XS1M18DA214D XS518B1CAM12 XS1N18NA349 XS618B1NAL2 XS2M12NB370 XS612B1NBL2 XS1M18DA214LD XS518B1CAL08M12 XS1N18NA349D XS618B1NAM12 XS2M12NB370D XS612B1NBM12 XS1M18DB210 XS518B1DBL2 XS1N18NA349L1 XS618B1NAL5 XS2M12PA370 XS612B1PAL2 XS1M18DB210B XS518B1DBM12 XS1N18NB340 XS518B1NBL2 XS2M12PA370D XS612B1PAM12 XS1M18DB210D XS518B1DBM12 XS1N18NB340D XS518B1NBM12 XS2M12PA370L1 XS612B1PAL5 XS1M18KP340 XS518B1PAL2 XS1N18NB349 XS618B1NBL2 XS2M12PA370L2 XS612B1PAL10 XS1M18KP340 XS518B1PBL2 XS1N18NB349D XS618B1NBM12 XS2M12PB370 XS612B1PBL2 XS1M18KP340 XS518B1NAL2 XS1N18NC410 XS518B1NAL2 XS2M12PB370D XS612B1PBM12 XS1M18KP340 XS518B1NBL2 XS1N18NC410 XS518B1NBL2 XS2M12PB370S XS612B1PBM12 XS1M18KP340D XS518B1PAM12 XS1N18NC410D XS518B1NAM12 XS2M12PC410D XS612B1PAM12 XS1M18KP340D XS518B1PBM12 XS1N18NC410D XS518B1NBM12 XS2M12PC410D XS612B1PBM12 XS1M18KP340D XS518B1NAM12 XS1N18NC410L1 XS518B1NAL5 XS2N12NA340 XS612B1NAL2 XS1M18KP340D XS518B1NBM12 XS1N18NC410L1 XS518B1NBL5 XS2N12NA340D XS612B1NAM12 XS1M18KP340L1 XS518B1PAL5 XS1N18PA340 XS518B1PAL2 XS2N12NA340L1 XS612B1NAL5 XS1M18KP340L1 XS518B1PBL5 XS1N18PA340D XS518B1PAM12 XS2N12NA340L2 XS612B1NAL10 XS1M18KP340L1 XS518B1NAL5 XS1N18PA340L1 XS518B1PAL5 XS2N12NB340 XS612B1NBL2 XS1M18KP340L1 XS518B1NBL5 XS1N18PA340L2 XS518B1PAL10 XS2N12NB340D XS612B1NBM12 XS1M18KP340L2 XS518B1PAL10 XS1N18PA349 XS618B1PAL2 XS2N12NC410 XS612B1NAL2 XS1M18KP340L2 XS518B1PBL10 XS1N18PA349D XS618B1PAM12 XS2N12NC410 XS612B1NBL2 XS1M18KP340L2 XS518B1NAL10 XS1N18PA349L1 XS618B1PAL5 XS2N12NC410D XS612B1NAM12 XS1M18KP340L2 XS518B1NBL10 XS1N18PA349L2 XS618B1PAL10 XS2N12NC410D XS612B1NBM12 XS1M18NA370 XS618B1NAL2 XS1N18PA349S XS618B1PAM12 XS2N12NC410L1 XS612B1NAL5 XS1M18NA370A XS618B1NAM12 XS1N18PB340 XS518B1PBL2 XS2N12NC410L1 XS612B1NBL5 XS1M18NA370B XS618B1NAM12 XS1N18PB340D XS518B1PBM12 $ 326 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Existing to New Substitution Old Design New Design Old Design New Design Old Design New Design XS1N18PB340L2 XS518B1PBL10 XS2N18NC410 XS618B1NBL2 XS1M30NA370 XS630B1NAL2 XS1N18PB349 XS618B1PBL2 XS2N18NC410D XS618B1NAM12 XS1M30NA370B XS630B1NAM12 XS1N18PB349D XS618B1PBM12 XS2N18NC410D XS618B1NBM12 XS1M30NA370C XS630B1NAM12 XS1N18PB349L1 XS618B1PBL5 XS2N18PA340 XS618B1PAL2 XS1M30NA370D XS630B1NAM12 XS1N18PB349L2 XS618B1PBL10 XS2N18PA340D XS618B1PAM12 XS1M30NA370G XS630B1NAM12 XS1N18PB349S XS618B1PBM12 XS2N18PA340L1 XS618B1PAL5 XS1M30NA370L1 XS630B1NAL5 XS1N18PC410 XS518B1PAL2 XS2N18PA340L2 XS618B1PAL10 XS1M30NA370L2 XS630B1NAL10 XS1N18PC410 XS518B1PBL2 XS2N18PB340 XS618B1PBL2 XS1M30NA370T XS630B1NAL2T XS1N18PC410D XS518B1PAM12 XS2N18PB340D XS618B1PBM12 XS1M30NB370 XS630B1NBL2 XS1N18PC410D XS518B1PBM12 XS2N18PC410 XS618B1PAL2 XS1M30NB370B XS630B1NBM12 XS1N18PC410L1 XS518B1PAL5 XS2N18PC410 XS618B1PBL2 XS1M30NB370D XS630B1NBM12 XS1N18PC410L1 XS518B1PBL5 XS2N18PC410D XS618B1PAM12 XS1M30PA349C XS630B1PAM12 XS1N18PC410P XS518B1PAL10 XS2N18PC410D XS618B1PBM12 XS1M30PA349D XS630B1PAM12 XS1N18PC410P XS518B1PBL10 XS2N18PC410L1 XS618B1PAL5 XS1M30PA370 XS630B1PAL2 XS2M18KP340 XS618B1PAL2 XS2N18PC410L1 XS618B1PBL5 XS1M30PA370A XS630B1PAM12 XS2M18KP340 XS618B1PBL2 XS3P18NA340 XS518B1NAL2 XS1M30PA370B XS630B1PAM12 XS2M18KP340 XS618B1NAL2 XS3P18NA340D XS518B1NAM12 XS1M30PA370C XS630B1PAM12 XS2M18KP340 XS618B1NBL2 XS3P18NA370 XS618B1NAL2 XS1M30PA370D XS630B1PAM12 XS2M18KP340D XS618B1PAM12 XS3P18PA340 XS518B1PAL2 XS1M30PA370G XS630B1PAM12 XS2M18KP340D XS618B1PBM12 XS3P18PA340D XS518B1PAM12 XS1M30PA370L1 XS630B1PAL5 XS2M18KP340D XS618B1NAM12 XS3P18PA340L1 XS518B1PAL5 XS1M30PA370L2 XS630B1PAL10 XS2M18KP340D XS618B1NBM12 XS3P18PA370 XS618B1PAL2 XS1M30PA370T XS630B1PAL2T XS2M18KP340L1 XS618B1PAL5 30 mm Cylindrical XS1M30PB370 XS630B1PBL2 XS2M18KP340L1 XS618B1PBL5 XS1M30DA210 XS530B1DAL2 XS1M30PB370B XS630B1PBM12 $ XS2M18KP340L1 XS618B1NAL5 XS1M30DA210B XS530B1DAM12 XS1M30PB370C XS630B1PBM12 XS2M18KP340L1 XS618B1NBL5 XS1M30DA210C XS530B1DAM12 XS1M30PB370D XS630B1PBM12 XS2M18KP340L2 XS618B1PAL10 XS1M30DA210D XS530B1DAM12 XS1M30PB370G XS630B1PBM12 XS2M18KP340L2 XS618B1PBL10 XS1M30DA210G XS530B1DAM12 XS1M30PB370L1 XS630B1PBL5 XS2M18KP340L2 XS618B1NAL10 XS1M30DA210L1 XS530B1DAL5 XS1M30PB370L2 XS630B1PBL10 XS2M18KP340L2 XS618B1NBL10 XS1M30DA210L2 XS530B1DAL10 XS1N30NA340 XS530B1NAL2 XS2M18NA370 XS618B1NAL2 XS1M30DA210LA XS530B1DAM12 XS1N30NA340D XS530B1NAM12 XS2M18NA370C XS618B1NAM12 XS1M30DA210LD XS530B1DAM12 XS1N30NA349 XS630B1NAL2 XS2M18NA370D XS618B1NAM12 XS1M30DB210 XS530B1DBL2 XS1N30NA349D XS630B1NAM12 XS2M18NA370L1 XS618B1NAL5 XS1M30DB210B XS530B1DBM12 XS1N30NA349L1 XS630B1NAL5 XS630B1NAL10 XS2M18NA370L2 XS618B1NAL10 XS1M30DB210D XS530B1DBM12 XS1N30NA349L2 XS2M18NA370T XS618B1NAM12T XS1M30KP340 XS530B1PAL2 XS1N30NB340 XS530B1NBL2 XS2M18NB370 XS618B1NBL2 XS1M30KP340 XS530B1PBL2 XS1N30NB349 XS630B1NBL2 XS2M18NB370D XS618B1NBM12 XS1M30KP340 XS530B1NAL2 XS1N30NB349D XS630B1NBM12 XS2M18PA370 XS618B1PAL2 XS1M30KP340 XS530B1NBL2 XS1N30NC410 XS530B1NAL2 XS2M18PA370C XS618B1PAM12 XS1M30KP340D XS530B1PAM12 XS1N30NC410 XS530B1NBL2 XS2M18PA370D XS618B1PAM12 XS1M30KP340D XS308B1PBM12 XS1N30NC410D XS530B1NAM12 XS530B1NBM12 XS2M18PA370G XS618B1PAM12 XS1M30KP340D XS530B1NAM12 XS1N30NC410D XS2M18PA370L1 XS618B1PAL5 XS1M30KP340D XS530B1NBM12 XS1N30PA340 XS530B1PAL2 XS2M18PA370L2 XS618B1PAL10 XS1M30KP340L1 XS530B1PAL5 XS1N30PA340D XS530B1PAM12 XS530B1PAL5 XS2M18PA370T XS618B1PAL2T XS1M30KP340L1 XS530B1PBL5 XS1N30PA340L1 XS2M18PB370 XS618B1PBL2 XS1M30KP340L1 XS530B1NAL5 XS1N30PA340L2 XS530B1PAL10 XS2M18PB370C XS618B1PBM12 XS1M30KP340L1 XS530B1NBL6 XS1N30PA349 XS630B1PAL2 XS2M18PB370D XS618B1PBM12 XS1M30KP340L2 XS530B1PAL10 XS1N30PA349D XS630B1PAM12 XS2M18PB370G XS618B1PBM12 XS1M30KP340L2 XS530B1PBL10 XS1N30PA349L1 XS630B1PAL5 XS630B1PAL10 XS2M18PB370L1 XS618B1PBL5 XS1M30KP340L2 XS530B1NAL10 XS1N30PA349L2 XS2M18PB370L2 XS618B1PBL10 XS1M30KP340L2 XS530B1NBL10 XS1N30PA349S XS630B1PAM12 XS2N18NA340 XS618B1NAL2 XS1M30KP370 XS630B1PAL2 XS1N30PB340 XS530B1PBL2 XS2N18NA340D XS618B1NAM12 XS1M30KP370 XS630B1PBL2 XS1N30PB340D XS530B1PBM12 XS2N18NA340L1 XS618B1NAL5 XS1M30KP370 XS630B1NAL2 XS1N30PB349 XS630B1PBL2 XS2N18NC410 XS618B1NAL2 XS1M30KP370 XS630B1NBL2 XS1N30PB349D XS630B1PBM12 Proximity Sensors Existing to New Substitution 327 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Existing to New Substitution Existing to New Substitution Old Design New Design Old Design New Design Old Design New Design XS1N30PB349L1 XS630B1PBL5 XS2N30PB340D XS630B1PBM12 XS1M18MA230B XS618B1MAU20 XS1N30PB349L2 XS630B1PBL10 XS2N30PC410 XS630B1PAL2 XS1M18MA230C XS618B1MAU20 XS1N30PC410 XS530B1PAL2 XS2N30PC410 XS630B1PBL2 XS1M18MA230G XS618B1MAU20 XS618B1MAU20 XS1N30PC410 XS530B1PBL2 XS2N30PC410D XS630B1PAM12 XS1M18MA230K XS1N30PC410D XS530B1PAM12 XS2N30PC410D XS630B1PBM12 XS1M18MA230L1 XS618B1MAL5 XS1N30PC410D XS530B1PBM12 XS2N30PC410L1 XS630B1PAL5 XS1M18MA230L2 XS618B1MAL10 XS1N30PC410L1 XS530B1PAL5 XS2N30PC410L1 XS630B1PBL5 XS1M18MA230T XS618B1MAL2T XS1N30PC410L1 XS530B1PBL5 XS3P30NA340 XS530B1NAL2 XS1M18MA239 XS618B1MAL2 XS1N30PC410L2 XS530B1PAL10 XS3P30NA340D XS530B1NAM12 XS1M18MA239A XS618B1MAU20 XS1N30PC410L2 XS530B1PBL10 XS3P30NA370 XS630B1NAL2 XS1M18MA239K XS618B1MAU20 XS2M30KP340 XS630B1PAL2 XS3P30PA340 XS530B1PAL2 XS1M18MA250 XS618B1MAL2 XS2M30KP340 XS630B1PAL2 XS3P30PA340D XS530B1PAM12 XS1M18MA250A XS618B1MAU20 XS2M30KP340 XS630B1PAL2 XS3P30PA340L1 XS530B1PAL5 XS1M18MA250H4 XS618B1MAL2 XS2M30KP340 XS630B1PAL2 XS3P30PA340L2 XS530B1PAL10 XS1M18MA250K XS618B1MAU20 XS2M30KP340D XS630B1PAM12 XS3P30PA370 XS630B1PAL2 XS1M18MA250KH4 XS618B1MAU20 XS2M30KP340D XS630B1PAM12 XS3P30PA370L1 XS630B1PAL5 XS1M18MA250L1 XS618B1MAL5 XS630B1PAL10 XS1M18MA250L2 XS618B1MAL10 XS1M18MB230 XS618B1MBL2 Proximity Sensors XS2M30KP340D XS630B1PAM12 XS3P30PA370L2 XS2M30KP340D XS630B1PAM12 12 mm Cylindrical XS2M30KP340L1 XS630B1PAL5 XS1M12MA230 XS612B1MAL2 XS1M18MB230A XS618B1MBU20 XS2M30KP340L1 XS630B1PAL5 XS1M12MA230K XS612B1MAU20 XS1M18MB230B XS618B1MBU20 XS618B1MBU20 " XS2M30KP340L1 XS630B1PAL5 XS1M12MA230L1 XS612B1MAL5 XS1M18MB230C XS2M30KP340L1 XS630B1PAL5 XS1M12MA230L2 XS612B1MAL10 XS1M18MB230G XS618B1MBU20 XS2M30KP340L2 XS630B1PAL10 XS1M12MA239 XS612B1MAL2 XS1M18MB230K XS618B1MBU20 XS2M30KP340L2 XS630B1PAL10 XS1M12MA239K XS612B1MAU20 XS1M18MB230L1 XS618B1MBL5 XS2M30KP340L2 XS630B1PAL10 XS1M12MA250 XS612B1MAL2 XS1M18MB230L2 XS618B1MBL10 XS2M30KP340L2 XS630B1PAL10 XS1M12MA250K XS612B1MAU20 XS1M18MB250 XS618B1MBL2 XS2M30NA370 XS630B1NAL2 XS1M12MA250L1 XS612B1MAL5 XS1M18MB250A XS618B1MBU20 XS2M30NA370D XS630B1NAM12 XS1M12MA250L2 XS612B1MAL10 XS1M18MB250K XS618B1MBU20 XS2M30NA370L1 XS630B1NAL5 XS1M12MB230 XS612B1MBL2 XS1M18MB250L1 XS618B1MBL5 XS2M30NB370 XS630B1NBL2 XS1M12MB230K XS612B1MBU20 XS1M18MB250L2 XS618B1MBL10 XS2M30NB370D XS630B1NBM12 XS1M12MB230L1 XS612B1MBL5 XS2M18DA210L2 XS612B1MAL10 XS2M30PA370 XS630B1PAL2 XS1M12MB230L2 XS612B1MBL10 XS2M18MA230 XS618B1MAL2 XS2M30PA370C XS630B1PAM12 XS1M12MB250 XS612B1MBL2 XS2M18MA230A XS618B1MAU20 XS2M30PA370D XS630B1PAM12 XS2M12MA230 XS612B1MAL2 XS2M18MA230C XS618B1MAU20 XS2M30PA370G XS630B1PAM12 XS2M12MA230K XS612B1MAU20 XS2M18MA230G XS618B1MAU20 XS2M30PA370L1 XS630B1PAL5 XS2M12MA230L1 XS612B1MAL5 XS2M18MA230K XS618B1MAU20 XS2M30PA370L2 XS630B1PAL10 XS2M12MA230L2 XS612B1MAL10 XS2M18MA230L1 XS618B1MAL5 XS618B1MAL10 XS2M30PA370T XS630B1PAL2T XS2M12MA250 XS612B1MAL2 XS2M18MA230L2 XS2M30PB370 XS630B1PBL2 XS2M12MA250K XS612B1MAU20 XS2M18MA230T XS618B1MAL2T XS2M30PB370C XS630B1PBM12 XS2M12MA250L1 XS612B1MAL5 XS2M18MA250 XS618B1MAL2 XS2M30PB370D XS630B1PBM12 XS2M12MA250L2 XS612B1MAL10 XS2M18MA250A XS618B1MAU20 XS2M30PB370L1 XS630B1PBL5 XS2M12MB230 XS612B1MBL2 XS2M18MA250K XS618B1MAU20 XS618B1MAL5 XS2M30PB370L2 XS630B1PBL10 XS2M12MB230K XS612B1MBU20 XS2M18MA250L1 XS2N30NA340 XS630B1NAL2 XS2M12MB230L1 XS612B1MBL5 XS2M18MA250L2 XS618B1MAL10 XS2N30NA340D XS630B1NAM12 XS2M12MB230L2 XS612B1MBL10 XS2M18MB230 XS618B1MBL2 XS2N30NB340 XS630B1NBL2 XS2M12MB250 XS612B1MBL2 XS2M18MB230A XS618B1MBU20 XS2N30NC410 XS630B1NAL2 XS2M12MB250L1 XS612B1MBL5 XS2M18MB230C XS618B1MBU20 XS618B1MBU20 XS2N30NC410 XS630B1NBL2 XS2M12MB250L2 XS612B1MBL10 XS2M18MB230G XS2N30NC410D XS630B1NAM12 XS3P12MA230 XS612B1MAL2 XS2M18MB230K XS618B1MBU20 XS2N30NC410D XS630B1NBM12 XS3P12MA230K XS612B1MAU20 XS2M18MB230L1 XS618B1MBL5 XS2N30PA340 XS630B1PAL2 XS3P12MA230L1 XS612B1MAL5 XS2M18MB230L2 XS618B1MBL10 XS2N30PA340D XS630B1PAM12 XS3P12MB230 XS612B1MBL2 XS2M18MB250 XS618B1MBL2 XS2N30PA340L1 XS630B1PAL5 18 mm Cylindrical XS2M18MB250A XS618B1MBU20 XS2N30PA340L2 XS630B1PAL10 XS1M18MA230 XS618B1MAL2 XS2M18MB250K XS618B1MBU20 XS2N30PB340 XS630B1PBL2 XS1M18MA230A XS618B1MAU20 XS2M18MB250L1 XS618B1MBL5 " 328 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Existing to New Substitution Old Design New Design Old Design New Design Old Design New Design XS2M18MB250L2 XS618B1MBL10 XS2M30MB230 XS630B1MBL2 XS7C40DP210TF XS7C1A1DAM8 + XSZBC10 XS3P18MA230 XS618B1MAL2 XS2M30MB230A XS630B1MBU20 XS7C40DP210TF XS7C1A1DBM8 + XSZBC10 XS3P18MA230A XS618B1MAU20 XS2M30MB230C XS630B1MBU20 XS7C40KPM40 XS9C11MPAM8 + XSZBC10 XS3P18MA230K XS618B1MAU20 XS2M30MB230G XS630B1MBU20 XS7C40KPM40 XS9C11MPBM8 + XSZBC10 XS3P18MA230L1 XS618B1MAL5 XS2M30MB230K XS630B1MBU20 XS7C40KPM40 XS9C11MNAM8 + XSZBC10 XS3P18MA230L2 XS618B1MAL10 XS2M30MB230L1 XS630B1MBL5 XS7C40KPM40 XS9C11MPBM8 + XSZBC10 XS3P18MB230 XS618B1MBL2 XS2M30MB230L2 XS630B1MBL10 XS7C40KPM40H29 XS9C11MPAM8 + XSZBC10 XS3P18MB230A XS618B1MBU20 XS2M30MB250 XS630B1MBL2 XS7C40KPM40H29 XS9C11MPBM8 + XSZBC10 XS3P18MB230K XS618B1MBU20 XS2M30MB250K XS630B1MBU20 XS7C40KPM40H29 XS9C11MNAM8 + XSZBC10 XS3P18MB230L1 XS618B1MBL5 XS2M30MB250L1 XS630B1MBL5 XS7C40KPM40H29 XS9C11MPBM8 + XSZBC10 XS3P30MA230 XS630B1MAL2 XS7C40KPM40H7 XS9C11MPAM8 + XSZBC10 30 mm Cylindrical " XS1M30MA230 XS630B1MAL2 XS3P30MA230A XS630B1MAU20 XS7C40KPM40H7 XS9C11MPBM8 + XSZBC10 XS1M30MA230A XS630B1MAU20 XS3P30MA230K XS630B1MAU20 XS7C40KPM40H7 XS9C11MNAM8 + XSZBC10 XS1M30MA230B XS630B1MAU20 XS3P30MA230L1 XS630B1MAL5 XS7C40KPM40H7 XS9C11MPBM8 + XSZBC10 XS1M30MA230C XS630B1MAU20 XS3P30MA230L2 XS630B1MAL10 XS7C40NC440 XS7C1A1NAM8 + XSZBC10 XS1M30MA230G XS630B1MAU20 XS3P30MB230 XS630B1MBL2 XS7C40NC440 XS7C1A1NBM8 + XSZBC10 XS1M30MA230K XS630B1MAU20 XS3P30MB230A XS630B1MBU20 XS7C40NC440D XS7C1A1NAM8 + XSZBC10 XS1M30MA230L1 XS630B1MAL5 XS3P30MB230K XS630B1MBU20 XS7C40NC440D XS7C1A1NBM8 + XSZBC10 XS1M30MA230L2 XS630B1MAL10 XS3P30MB230L1 XS630B1MBL5 XS7C40NC440H29 XS7C1A1NAM8 + XSZBC10 XS1M30MA230T XS630B1MAL2T XSC Rectangular XS7C40NC440H29 XS7C1A1NBM8 + XSZBC10 XS1M30MA239 XS630B1MAL2 XSCA150549 XS8C1A1MAL01U20 + XSZBC10 XS7C40NC449 XS8C1A1NAM8 + XSZBC10 XS1M30MA239A XS630B1MAU20 XSCA150549 XS8C1A1MBL01U20 + XSZBC10 XS7C40NC449 XS8C1A1NBM8 + XSZBC10 XS1M30MA250 XS630B1MAL2 XSD Rectangular XS1M30MA250A XS630B1MAU20 XSDA400519 XS1M30MA250AH4 XS630B1MAU20 XS1M30MA250H4 " " Proximity Sensors Existing to New Substitution XS7C40NC449H29 XS8C1A1NAM8 + XSZBC10 XS8D1A1MAU20 + XSZBD10 XS7C40NC449H29 XS8C1A1NBM8 + XSZBC10 XSDA400519 XS8D1A1MBU20 + XSZBD10 XS7C40PC440 XS7C1A1PAM8 + XSZBC10 XS630B1MAL2 XSDA400519H7 XS8D1A1MAU20 + XSZBD10 XS7C40PC440 XS7C1A1PBM8 + XSZBC10 XS1M30MA250K XS630B1MAU20 XSDA400519H7 XS8D1A1MBU20 + XSZBD10 XS7C40PC440D XS7C1A1PAM8 + XSZBC10 XS1M30MA250KH4 XS630B1MAU20 XSDA500519 XS8D1A1MAU20 + XSZBD10 XS7C40PC440D XS7C1A1PBM8 + XSZBC10 XS1M30MA250L1 XS630B1MAL5 XSDA500519 XS8D1A1MBU20 + XSZBD10 XS7C40PC440H29 XS7C1A1PAM8 + XSZBC10 XS1M30MA250L2 XS630B1MAL10 XSDA500519H7 XS8D1A1MAU20 + XSZBD10 XS7C40PC440H29 XS7C1A1PBM8 + XSZBC10 XS1M30MB230 XS630B1MBL2 XSDA500519H7 XS8D1A1MBU20 + XSZBD10 XS7C40PC440H7 XS7C1A1PAM8 + XSZBC10 XS1M30MB230A XS630B1MBU20 XSDA505539H4 XS8D1A1MAU20 + XSZBD10 XS7C40PC440H7 XS7C1A1PBM8 + XSZBC10 XS1M30MB230B XS630B1MBU20 XSDA505539H4 XS8D1A1MBU20 + XSZBD10 XS7C40PC449 XS8C1A1PAM8 + XSZBC10 XS1M30MB230C XS630B1MBU20 XSDA600519 XS8D1A1MAU20 + XSZBD10 XS7C40PC449 XS8C1A1PBM8 + XSZBC10 XS1M30MB230G XS630B1MBU20 XSDA600519 XS8D1A1MBU20 + XSZBD10 XS7C40PC449H29 XS8C1A1PAM8 + XSZBC10 XS1M30MB230K XS630B1MBU20 XSDA600519H7 XS8D1A1MAU20 + XSZBD10 XS7C40PC449H29 XS8C1A1PBM8 + XSZBC10 XS1M30MB230L1 XS630B1MBL5 XSDA600519H7 XS8D1A1MBU20 + XSZBD10 XS7C40PC449H7 XS8C1A1PAM8 + XSZBC10 XS1M30MB230L2 XS630B1MBL10 XSDM500538 XS8D1A1MAU20 + XSZBD10 XS7C40PC449H7 XS8C1A1PBM8 + XSZBC10 XS1M30MB250 XS630B1MBL2 XSDM500538 XS8D1A1MBU20 + XSZBD10 XS7T2DA210 XS7E1A1DAL2 + XSZBE10 XS1M30MB250A XS630B1MBU20 XSDM600539 XS8D1A1MAU20 + XSZBD10 XS7T2DA214LD XS7E1A1CAL08M12 + XSZBE10 XS1M30MB250K XS630B1MBU20 XSDM600539 XS8D1A1MBU20 + XSZBD10 XS7T2DA214LD01 XS7E1A1CAL01M12 + XSZBE10 XS1M30MB250L1 XS630B1MBL5 XSDM600539H7 XS8D1A1MAU20 + XSZBD10 XS7T2NC440 XS7E1A1NAL2 + XSZBE10 XS1M30MB250L2 XS630B1MBL10 XSDM600539H7 XS8D1A1MBU20 + XSZBD10 XS7T2NC440 XS7E1A1NBL2 + XSZBE10 XS2M30MA230 XS630B1MAL2 XS7 Rectangular XS7T2NC440LD XS7E1A1NAL01M12 + XSZBE10 XS2M30MA230A XS630B1MAU20 XS7C40DA210 XS7C1A1DAM8 + XSZBC10 XS7T2NC440LD XS7E1A1NBL01M12 + XSZBE10 XS2M30MA230C XS630B1MAU20 XS7C40DA210A XS7C1A1DAM8 + XSZBC10 XS7T2PC440 XS7E1A1PAL2 + XSZBE10 XS2M30MA230G XS630B1MAU20 XS7C40DA214D XS7C1A1CAL08M12 + XSZBC10 XS7T2PC440 XS7E1A1PBL2 + XSZBE10 XS2M30MA230K XS630B1MAU20 XS7C40DP210 XS7C1A1DAM8 + XSZBC10 XS7T2PC440LD XS7E1A1PAL08M12 + XSZBE10 XS2M30MA230L1 XS630B1MAL5 XS7C40DP210 XS7C1A1DBM8 + XSZBC10 XS7T2PC440LD XS7E1A1PBL08M12 + XSZBE10 XS2M30MA230L2 XS630B1MAL10 XS7C40DP210H29 XS7C1A1DAM8 + XSZBC10 XS7T4DA210 XS7C1A1DAL2 + XSZBC10 XS2M30MA230T XS630B1MAL2T XS7C40DP210H29 XS7C1A1DBM8 + XSZBC10 XS7T4DA214LD XS7C1A1CAL08M12 + XSZBC10 XS2M30MA250 XS630B1MAL2 XS7C40DP210H7 XS7C1A1DAM8 + XSZBC10 XS7T4DA214LD01 XS7C1A1CAL01M12 + XSZBC10 XS2M30MA250K XS630B1MAU20 XS7C40DP210H7 XS7C1A1DBM8 + XSZBC10 XS7T4NC440 XS7C1A1NAL2 + XSZBC10 XS2M30MA250L1 XS630B1MAL5 XS7C40DP210TT XS7C1A1DAM8 + XSZBC10 XS7T4NC440 XS7C1A1NBL2 + XSZBC10 XS2M30MA250L2 XS630B1MAL10 XS7C40DP210TT XS7C1A1DBM8 + XSZBC10 XS7T4NC440LD XS7C1A1NAL01M12 + XSZBC10 $ 329 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Existing to New Substitution Existing to New Substitution Old Design New Design XS7T4NC440LD XS7C1A1NBL01M12 + XSZBC10 XS7 Rectangular" XS7T4PC440 XS7C1A1PAL2 + XSZBC10 XS7T4PC440 XS7C1A1PBL2 + XSZBC10 XS7T4PC440LD XS7C1A1PAL01M12 + XSZBC10 XS7C40DP210 XS8C1A1MAL01U20 + XSZBC10 XSDC407138 XS7D1A1DAM12 + XSZBD10 XS7T4PC440LD XS7C1A1PBL01M12 + XSZBC10 XS7C40DP210 XS8C1A1MBL01U20 + XSZBC10 XSDC407139 XS7D1A1DAM12 + XSZBD10 XS7C40DP210H29 XS8C1A1MAL01U20 + XSZBC10 XSDC407139D4 XS7D1A1DAM12 + XSZBD10 XS8C40DA210 XS7C1A1DAL01M12 + XSZBC10 XS7C40DP210H29 XS8C1A1MBL01U20 + XSZBC10 XSDC407139H7 XS7D1A1DAM12 + XSZBD10 XS8C40DP210 XS8C1A1DAM8 + XSZBC10 XS7C40DP210H7 XS8C1A1MAL01U20 + XSZBC10 XSDC407139LD XS7D1A1DAM12 + XSZBD10 XS8C40DP210 XS8C1A1DBM8 + XSZBC10 XS7C40DP210H7 XS8C1A1MBL01U20 + XSZBC10 XSDC407139LD01 XS7D1A1DAM12 + XSZBD10 XS8C40DP210H29 XS8C1A1DAM8 + XSZBC10 XS7C40DP210TT XS8C1A1MAL01U20 + XSZBC10 XSDC507139 XS7D1A1DAM12 + XSZBD10 XS8C40DP210H29 XS8C1A1DBM8 + XSZBC10 XS7C40DP210TT XS8C1A1MBL01U20 + XSZBC10 XSDC607139 XS7D1A1DAM12 + XSZBD10 XS8C40DP210H7 XS8C1A1DAM8 + XSZBC10 XS7C40DP210TF XS8C1A1MAL01U20 + XSZBC10 XSDC607139H7 XS7D1A1DAM12 + XSZBD10 XS8C40DP210H7 XS8C1A1DBM8 + XSZBC10 XS7C40DP210TF XS8C1A1MBL01U20 + XSZBC10 XSDC607139LD XS7D1A1DAM12 + XSZBD10 XS8C40NC440 XS8C1A1NAM8 + XSZBC10 XS7C40FP260 XS8C1A1MAL01U20 + XSZBC10 XSDC607139LD01 XS7D1A1DAM12 + XSZBD10 XS8C40NC440 XS8C1A1NBM8 + XSZBC10 XS7C40FP260 XS8C1A1MBL01U20 + XSZBC10 XSDC607319 XS7D1A1DAM12 + XSZBD10 XS8C40NC440H29 XS8C1A1NAM8 + XSZBC10 XS7C40FP260A XS8C1A1MAL01U20 + XSZBC10 XSDC607319 XS7D1A1DBM12 + XSZBD10 XS8C40NC440H29 XS8C1A1NBM8 + XSZBC10 XS7C40FP260A XS8C1A1MBL01U20 + XSZBC10 XSDH407339 XS8D1A1PAM12 + XSZBD10 XS8C40NC449 XS8C1A1NAM8 + XSZBC10 XS7C40FP260H29 XS8C1A1MAL01U20 + XSZBC10 XSDH407339 XS8D1A1PBM12 + XSZBD10 XS8C40NC449 XS8C1A1NBM8 + XSZBC10 XS7C40FP260H29 XS8C1A1MBL01U20 + XSZBC10 XSDH407339H7 XS8D1A1PAM12 + XSZBD10 XS8C40NC449H29 XS8C1A1NAM8 + XSZBC10 XS7C40FP260H7 XS8C1A1MAL01U20 + XSZBC10 XSDH407339H7 XS8D1A1PBM12 + XSZBD10 XS8C40NC449H29 XS8C1A1NBM8 + XSZBC10 XS7C40FP260H7 XS8C1A1MBL01U20 + XSZBC10 XSDH607339 XS8D1A1PAM12 + XSZBD10 XS8C40NC449H7 XS8C1A1NAM8 + XSZBC10 XS7C40FP260TF XS8C1A1MAL01U20 + XSZBC10 XSDH607339 XS8D1A1PBM12 + XSZBD10 XS8C40NC449H7 XS8C1A1NBM8 + XSZBC10 XS7C40FP260TF XS8C1A1MBL01U20 + XSZBC10 XSDH607339H7 XS8D1A1PAM12 + XSZBD10 XS8C40PC440 XS8C1A1PAM8 + XSZBC10 XS7C40FP260TT XS8C1A1MAL01U20 + XSZBC10 XSDH607339H7 XS8D1A1PBM12 + XSZBD10 XS8C40PC440 XS8C1A1PBM8 + XSZBC10 XS7C40FP260TT XS8C1A1MBL01U20 + XSZBC10 XSDH607339TF XS8D1A1PAM12 + XSZBD10 XS8C40PC440D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSDH607339TF XS8D1A1PBM12 + XSZBD10 XS8C40PC440D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230 XS8C1A1MBL01U20 + XSZBC10 XSDJ407339 XS8D1A1NAM12 + XSZBD10 XS8C40PC440H29 XS8C1A1PAM8 + XSZBC10 XS7C40MP230A XS8C1A1MAL01U20 + XSZBC10 XSDJ407339 XS8D1A1NBM12 + XSZBD10 XS8C40PC440H29 XS8C1A1PBM8 + XSZBC10 XS7C40MP230A XS8C1A1MBL01U20 + XSZBC10 XSDJ407339H7 XS8D1A1NAM12 + XSZBD10 XS8C40PC440H7 XS8C1A1PAM8 + XSZBC10 XS7C40MP230H29 XS8C1A1MAL01U20 + XSZBC10 XSDJ407339H7 XS8D1A1NBM12 + XSZBD10 XS8C40PC440H7 XS8C1A1PBM8 + XSZBC10 XS7C40MP230H29 XS8C1A1MBL01U20 + XSZBC10 XSDJ607339 XS8D1A1NAM12 + XSZBD10 XS8C40PC449 XS8C1A1PAM8 + XSZBC10 XS7C40MP230H7 XS8C1A1MAL01U20 + XSZBC10 XSDJ607339 XS8D1A1NBM12 + XSZBD10 XS8C40PC449 XS8C1A1PBM8 + XSZBC10 XS7C40MP230H7 XS8C1A1MBL01U20 + XSZBC10 XSDJ607339H7 XS8D1A1NAM12 + XSZBD10 XS8C40PC449D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230TF XS8C1A1MAL01U20 + XSZBC10 XSDJ607339H7 XS8D1A1NBM12 + XSZBD10 XS8C40PC449D XS8C1A1PAL01M12 + XSZBC10 XS7C40MP230TF XS8C1A1MBL01U20 + XSZBC10 XSE Rectangular$ XS8C40PC449H29 XS8C1A1PAM8 + XSZBC10 XS7C40MP230TT XS8C1A1MAL01U20 + XSZBC10 XSEC107130 XS7E1A1DAL01M12 + XSZBE10 XS8C40PC449H29 XS8C1A1PBM8 + XSZBC10 XS7C40MP230TT XS8C1A1MBL01U20 + XSZBC10 XSEC1071300 XS7E1A1DAL2 + XSZBE10 XS8C40PC449H7 XS8C1A1PAM8 + XSZBC10 XS8 Rectangular" XS8C40PC449H7 XS8C1A1PBM8 + XSZBC10 XS8C40DA210 XS8C1A1MAL01U20 + XSZBC10 XSEC1071301 XS7E1A1DAL01M12 + XSZBE10 XS8T2NC440 XS8E1A1NAL2 + XSZBE10 XS8C40DP210 XS8C1A1MAL01U20 + XSZBC10 XSEC1071302 XS7E1A1DAL01M12 + XSZBE10 XS8T2NC440 XS8E1A1NBL2 + XSZBE10 XS8C40DP210 XS8C1A1MBL01U20 + XSZBC10 XSEC1071304 XS7E1A1DAL01M12 + XSZBE10 XS8T2NC440LD XS8E1A1NAL01M12 + XSZBE10 XS8C40DP210H29 XS8C1A1MAL01U20 + XSZBC10 XSEC107130D4 XS7E1A1DAL01M12 + XSZBE10 XS8T2NC440LD XS8E1A1NBL01M12 + XSZBE10 XS8C40DP210H29 XS8C1A1MBL01U20 + XSZBC10 XSEC107130H7 XS7E1A1DAL01M12 + XSZBE10 XS8T2PC440 XS8E1A1PAL2 + XSZBE10 XS8C40DP210H7 XS8C1A1MAL01U20 + XSZBC10 XSEC107133 XS7E1A1DAL01M12 + XSZBE10 XS8T2PC440 XS8E1A1PBL2 + XSZBE10 XS8C40DP210H7 XS8C1A1MBL01U20 + XSZBC10 XSEC1071330 XS7E1A1DAL2 + XSZBE10 XS8T2PC440LD XS8E1A1PAL01M12 + XSZBE10 XS8C40FP260 XS8C1A1MAL01U20 + XSZBC10 XSEC1071331 XS7E1A1DAL01M12 + XSZBE10 XS8T2PC440LD XS8E1A1PBL01M12 + XSZBE10 XS8C40FP260 XS8C1A1MBL01U20 + XSZBC10 XSEC1071332 XS7E1A1DAL01M12 + XSZBE10 XS8T4NC440 XS8C1A1NAL2 + XSZBC10 XS8C40FP260H29 XS8C1A1MAL01U20 + XSZBC10 XSEC1071334 XS7E1A1DAL01M12 + XSZBE10 XS8T4NC440 XS8C1A1NBL2 + XSZBC10 XS8C40FP260H29 XS8C1A1MBL01U20 + XSZBC10 XSEC107133D4 XS7E1A1DAL01M12 + XSZBE10 XS8T4NC440LD XS8C1A1NAL01M12 + XSZBC10 XS8C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSEC107230 XS7E1A1DBM12 + XSZBE10 XS8T4NC440LD XS8C1A1NBL01M12 + XSZBC10 XS8C40MP230 XS8C1A1MBL01U20 + XSZBC10 XSEC1072301 XS7E1A1DBL01M12 + XSZBE10 XS8T4PC440 XS8C1A1PAL2 + XSZBC10 XS8C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSEC107233 XS7E1A1DBM12 + XSZBE10 XS8T4PC440 XS8C1A1PBL2 + XSZBC10 XS8C40MP230 XS8C1A1MAL01U20 + XSZBC10 XSEC1072331 XS7E1A1DBL08M12 + XSZBE10 XS8T4PC440LD XS8C1A1PAL01M12 + XSZBC10 XS8C40MP230H29 XS8C1A1MAL01U20 + XSZBC10 XSEC1571300 XS7E1A1DAL2 + XSZBE10 XS8T4PC440LD XS8C1A1PBL01M12 + XSZBC10 XS8C40MP230H29 XS8C1A1MBL01U20 + XSZBC10 XSEC1571330 XS7E1A1DAL2 + XSZBE10 XS8 Rectangular $ Old Design New Design Old Design New Design XS8C40MP230H7 XS8C1A1MAL01U20 + XSZBC10 XS7C40DA210 XS8C1A1MAL01U20 + XSZBC10 XS8C40MP230H7 XS8C1A1MBL01U20 + XSZBC10 XS7C40DA210A XS8C1A1MAL01U20 + XSZBC10 XSD Rectangular$ Proximity Sensors XSEC1071300L05 XS7E1A1DAL01M12 + XSZBE10 330 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Existing to New Substitution Existing to New Substitution Old Design New Design Old Design New Design Old Design New Design XSC Rectangular" XSCA150549 XS8C1A1MAL01U20 + XSZBC10 XSCA150549 XS8C1A1MBL01U20 + XSZBC10 XSDA400519 XS8D1A1MAU20 + XSZBD10 XSDA400519 XS8D1A1MBU20 + XSZBD10 XSDA400519H7 XS8D1A1MAU20 + XSZBD10 XSDA400519H7 XS8D1A1MBU20 + XSZBD10 XSDA500519 XS8D1A1MAU20 + XSZBD10 XSDA500519 XS8D1A1MBU20 + XSZBD10 XSDA500519H7 XS8D1A1MAU20 + XSZBD10 XSDA500519H7 XS8D1A1MBU20 + XSZBD10 XSDA505539H4 XS8D1A1MAU20 + XSZBD10 XSDA505539H4 XS8D1A1MBU20 + XSZBD10 XSDA600519 XS8D1A1MAU20 + XSZBD10 XSDA600519 XS8D1A1MBU20 + XSZBD10 XSDA600519H7 XS8D1A1MAU20 + XSZBD10 XSDA600519H7 XS8D1A1MBU20 + XSZBD10 XSDM500538 XS8D1A1MAU20 + XSZBD10 XSDM500538 XS8D1A1MBU20 + XSZBD10 XSDM600539 XS8D1A1MAU20 + XSZBD10 XSDM600539 XS8D1A1MBU20 + XSZBD10 XSDM600539H7 XS8D1A1MAU20 + XSZBD10 XSDM600539H7 XS8D1A1MBU20 + XSZBD10 Proximity Sensors XSD Rectangular" 331 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors AC Only to AC/DC Cross Reference AC Only to AC/DC Cross Reference Proximity Sensors Obsolete Part Number Replaced by Part Number AC XS1M12FA260 XS1M12FA260K XS1M12FB260 XS1M12FB260K XS1M18FA260 XS1M18FA260A XS1M18FA260K XS1M18FB260 XS1M18FB260A XS1M18FB260K XS1M30FA260 XS1M30FA260A XS1M30FA260K XS1M30FB260 XS1M30FB260A XS1M30FB260K XS2M12FA260 XS2M12FA260K XS2M12FB260 XS2M12FB260K XS2M18FA260 XS2M18FA260A XS2M18FA260K XS2M18FB260 XS2M18FB260A XS2M18FB260K XS2M30FA260 XS2M30FA260A XS2M30FA260K XS2M30FB260 XS2M30FB260A XS2M30FB260K XS3P12FA260 XS3P12FA260K XS3P12FB260 XS3P12FB260K XS3P18FA260 XS3P18FA260A XS3P18FA260K XS3P18FB260 XS3P18FB260A XS3P18FB260K XS3P30FA260 XS3P30FA260A XS3P30FA260K XS3P30FB260 XS3P30FB260A XS3P30FB260K XS4P12FA260 XS4P12FA260K XS4P12FB260 XS4P12FB260K XS4P18FA260 XS4P18FA260A XS4P18FA260K XS4P18FB260 XS4P18FB260A XS4P18FB260K XS4P30FA260 XS4P30FA260A XS4P30FA260K XS4P30FB260 XS4P30FB260A XS4P30FB260K AC/DC XS1M12MA230 XS1M12MA230K XS1M12MB230 XS1M12MB230K XS1M18MA230 XS1M18MA230A XS1M18MA230K XS1M18MB230 XS1M18MB230A XS1M18MB230K XS1M30MA230 XS1M30MA230A XS1M30MA230K XS1M30MB230 XS1M30MB230A XS1M30MB230K XS2M12MA230 XS2M12MA230K XS2M12MB230 XS2M12MB230K XS2M18MA230 XS2M18MA230A XS2M18MA230K XS2M18MB230 XS2M18MB230A XS2M18MB230K XS2M30MA230 XS2M30MA230A XS2M30MA230K XS2M30MB230 XS2M30MB230A XS2M30MB230K XS3P12MA230 XS3P12MA230K XS3P12MB230 XS3P12MB230K XS3P18MA230 XS3P18MA230A XS3P18MA230K XS3P18MB230 XS3P18MB230A XS3P18MB230K XS3P30MA230 XS3P30MA230A XS3P30MA230K XS3P30MB230 XS3P30MB230A XS3P30MB230K XS4P12MA230 XS4P12MA230K XS4P12MB230 XS4P12MB230K XS4P18MA230 XS4P18MA230A XS4P18MA230K XS4P18MB230 XS4P18MB230A XS4P18MB230K XS4P30MA230 XS4P30MA230A XS4P30MA230K XS4P30MB230 XS4P30MB230A XS4P30MB230K 332 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors What is a Proximity Sensor? What is a Proximity Sensor? It is an important component in an automation control system. It transmits information relating to the operating conditions of a machine to the logic processing system: Composition Detection stage Output stage * Presence, passage, flow of parts * End of travel * Rotation and counting. Essentially, it is a non-contact part presence detector. OUTPUT SWITCH OUTPUT DRIVER Detection stage * type of mounting (cylindrical, rectangular) * detection characteristics (sensing distance, hysteresis) Proximity Sensors OSCILLATOR Output stage * type of supply (DC, AC, AC/DC) * electrical characteristics (current and voltage) Application Advantages * no physical contact with the target * no wear, possibility of detecting fragile or freshly painted objects * high operating rate * perfect compatibility with electronic automated systems * high approach speeds * fast response * rugged, fully encapsulated * excellent resistance to industrial environments * solid state, no moving parts * life of the device is independent of the number of operations 333 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Why the Different Types of Sensors? Why the Different Types of Sensors? Suitable for the detection of metal objects Inductive Sensor * Identifies only metal targets * Predictable sensing technology--few variables * Reliable industrial technology Proximity Sensors Principle of operation Target Target An inductive proximity sensor is essentially comprised of an oscillator whose windings constitute the sensing face. An electromagnetic field is generated in front of these windings. When a metal object is placed within this field, the resulting currents induced into the target form an additional load, and the oscillations cease. This causes the output driver to operate, producing an ON or OFF output signal. 334 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Why the Different Types of Sensors? Why the Different Types of Sensors? Suitable for the detection of non-conductive targets, liquids and powders Capacitive Sensor * Detects any material * Affected by environment: humidity, dust, etc. Proximity Sensors * Best for: -- bulk material -- liquids -- targets behind a separation wall Principle of operation Target Target An capacitive proximity sensor is basically comprised of an oscillator whose capacitors constitute the sensing face. When a conducting or insulating material with a permittivity greater than air is placed within this field, it modifies the coupling capacitance and causes oscillations. This actuates the output driver, and, depending on the model, an ON or OFF output signal is produced. 335 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Detection Stage Detection Stage Tubular type Metal housing pes Housing ty Short case Plastic housing Standard (Form A) Standard (Form A) Short case Indexed mounting bracket omni-directional LED Bracket + sensor adjustments omni-directional LED Stop, for indexing the proximity sensor Proximity Sensors es Advantag * Simple installation and set-up: pre-wired or connector models * Excellent environmental protection: - encapsulated - metal housing (plated brass) - plastic or stainless steel housing (food, pharmaceuticals) * Two choices: - very short for restricted access areas - standard (form A) length for ease of replacement * No adjustment replacement by using a patented indexing mounting bracket Block type Non plug-in type Plug-in type LED es Advantag LED * Direct interchangeability, no need for readjustment * Flexibility of connections: screw terminals or connector * Long sensing distance 336 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Sensing Parameters Sensing Parameters Target Operating zone Operating zone The targets are generally of steel, and of a size equivalent to the sensing face of the sensor. To ensure detection, the target should pass at a distance less than or equal to the usable sensing distance given in the data sheet of the sensor selected. Not suitable Suitable (shielded) (unshielded) for flush Suitabiliy in metal mounting es Advantag * No lateral effect es Advantag * Sensing distance + 50 to + 100% But * Reduced sensing distance But * Space required around the device to eliminate the effects of the surrounding metal 337 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Circular LED indicator Operating state Proximity Sensors Output Stage Parameters Output Stage Parameters AC or AC/DC sensors for AC circuits Check that the power supply range limits of the proximity sensor are compatible with the nominal voltage of the AC supply used. ply Sensors for DC circuits Power sup Where a DC supply is available, check that the voltage limits of the sensor, including ripple, are compatible with the supply used. If an AC supply is available, a suitable DC power supply must be selected. A simple one has a transformer, a rectifier, and a smoothing capacitor. Proximity Sensors AC 50 - 60 Hz Ve + Vs V C - voltage Vs without C (non-filtered) V V peak V av. V rms V t Where voltage is derived from a single phase AC supply, it must be rectified and filtered to ensure that: * The peak voltage of the DC supply is lower than the maximum operating voltage of the sensor, peak voltage = rated voltage Ve x 2. * The minimum voltage of the DC supply is greater than the minimum voltage rating of the sensor, given that V = (I x t) / C. V = maximum ripple: 10% (V) i = anticipated load current (mA) t = period of 1 cycle (8.8 m sec. full wave rectified 60 Hz frequency voltage) C = capacitance (F) As a general rule, use a transformer with a lower secondary voltage (Ue) than the required DC voltage (U). Example: 18 Vac to obtain 24 Vdc 35 Vac to obtain 48 Vdc Mount a filtering capacitor of minimum 400 F per sensor or 2000 F for each ampere of load current required. NOTE: Tubular 3 wire DC universal models (10-58 V), 3 wire DC XSF models, and all AC/DC models can be supplied from full-wave rectified non-filtered (no capacitor C in the diagram above) power supplies. 338 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Output Stage Parameters Output Stage Parameters 2 Wire type DC, 2 wire, not polarity conscious BN AC 2 wire BN ~ -/+ nal Output sig XS XS Load R Load R BU +/- AC/DC 2 wire BU ~ BN ~/ Proximity Sensors XS Load R BU ~/ 2 wire sensors are wired in series with the load to be switched. They are subject to: * a residual current (leakage current) - in the open state * a voltage drop - in the closed state For the AC and AC/DC versions, certain models are protected against short-circuits. Refer to the product characteristics. es Advantag * They can be wired in the same way as mechanical limit switches. * For the DC and AC/DC versions, they can be connected to either positive (PNP) or negative (NPN) logic inputs. * Polarity insensitive versions, no risk of incorrect connection. * AC/DC versions, reduces stock requirements But Check the possible effects of residual current and voltage drop on the input device controlled (pick-up and drop-out thresholds). 339 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Output Stage Parameters Output Stage Parameters 3 Wire type 3 wire type PNP nal Output sig 3 wire type NPN + + BN XS S BN XS Load S - - BU BU 3 wire type, programmable PNP/NPN/N.O./N.C. Polarity (case 1) Polarity (case 2) - + + - BN BN BN C XS Proximity Sensors C Load BK BK BU BU C NPN N.C. PNP N.C. BK C C PNP N.O. - L : Load BU + NPN N.O. The sensors in this category have: * 2 wires for the power supply * 1 wire for the output signal NOTE: Some models include an additional wire for a complementary output 4 wire type, N.O. + N.C. The technology is still 3 wires. They are protected against reverse supply polarity and against overloads and short-circuit of the load. For the DC version, there are two types of sensor: * Basic sensor -- PNP model, switching the positive side to the load (sourcing) -- NPN model, switching the negative side to the load (sinking) * Universal DC sensors A single universal sensor, depending on the wiring connections can perform any of the following 4 functions: PNP/N.O., PNP/N.C., NPN/N.O., NPN/N.C. es Advantag * Best switching characteristics: no residual current, low voltage drop, fast * N.O. + N.C. versions * Universal versions, reduces stock requirements But Requires the use of a specialized sensor (PNP or NPN, function of the load connection, to negative or positive, respectively) or a selectable universal type. 340 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Output Stage Parameters Output Stage Parameters Analog type + + nal Output sig XS XS S I S I Load - Load 2 wire type These proximity sensors convert the approach of a metal target towards the sensing face into a current output signal which is proportional to the distance between the target and the sensing face. Two models: dual voltage: Output: single voltage: Output: 24/48 Vdc 0 - 10 mA with 3 wire connection 4 - 14 mA with 2 wire connection 24 Vdc 0 - 16 mA with 3 wire connection 4 - 20 mA with 2 wire connection es Advantag * Output signal proportional to the distance. * Two or three wire connection using the same device. 341 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors 3 wire type Proximity Sensors Output Stage Parameters Output Stage Parameters Namur type nal Output sig Load R = 1K + 7 to 12 Vdc - Proximity Sensors Namur type proximity sensors (DIN 19234) are electronic sensors in which the current consumption varies when a metal object approaches. Their operating principle, together with their compact size, enables them to be used in a large number of applications: * Intrinsically safe (hazardous environments, i.e. explosive). Sensors are used with NY2 intrinsically safe relay/amplifier or equivalent, approved intrinsically safe solid state input. * Non-intrinsically safe (normal, safe zone). NAMUR sensors associated with a power supply and amplifier unit or equivalent solid state input. es Advantag * Can work in hazardous environments. * Basic product, without amplifier. * Compact size. 342 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Output Stage Parameters Output Stage Parameters Cable Connector Screw Terminals Features Features Features Pre-wired sealed cable, excellent resistance to splashing liquid (IP67) or cutting oils (IP68). Ease of installation and replacement. Flexibility: user selects type and length of cable. Note In practice, the preceding information enables the selection and installation of a proximity sensor for applications having normal operating conditions. The following pages contain details for applications which need more specific information. 343 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Method ofn connectio Proximity Sensors Environmental Parameters Environmental Parameters The XS sensors are tested according to IEC 60947.5.2 standard (similar to the proposed new NEMA ICS 5-4-1999x standard). ELECTRO-STATIC DISCHARGES ELECTRO-STATIC DISCHARGE gnetic Electromaence interfer DC versions * level 2 immunity (3 wire type) * level 3 immunity (2 wire type) AC/DC versions INSULATING FLOOR (carpeting) IEC 1000-4-2 4 kV 10 kV 15 kV LEVEL 2 LEVEL 3 LEVEL 4 * level 4 immunity RADIATING ELECTRO-MAGNETIC FIELD DC and AC/DC versions ELECTRO-MAGNETIC WAVES * level 3 immunity (RFI Radio Frequency Immunity) Proximity Sensors WALKIE TALKIE IEC 1000-4-3 10 V / meter LEVEL 3 FAST TRANSIENTS STOP START CONTROL MOTOR DC versions IEC 1000-4-4 0.5 kV 1 kV 2 kV LEVEL 2 LEVEL 3 LEVEL 4 CAPACITIVE COUPLING * level 3 immunity AC/DC versions * level 4 immunity Extended range DC MOTOR START/STOP INTERFERENCE * level 3 immunity SHOCK VOLTAGES DC and AC/DC versions * level 3 immunity (over 8 mm diameter) MAINS FACTORY LIGHTNING * level 2 immunity (tubular 8 mm and smaller) OVERVOLTAGE TRANSFORMER IEC 947.5.2 IMPULSE VOLTAGE 1 kV 2,5 kV 5 kV LEVEL 2 LEVEL 3 LEVEL 4 344 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Environmental Parameters Environmental Parameters Temperature: where sensors are used outside the ranges shown, reliable operation cannot be assured and permanent damage could result. re Temperatuls Chemica Standard length tubular sensors have a very large temperature range: -25 C to 80 C. NOTE: For extended temperature range, consult factory. Chemicals: due to the very wide range of chemicals which are found in modern industry, it is very difficult to give general guidelines on sensor applications. To ensure lasting efficient operation, it is essential that the chemicals coming in contact with the sensors will not affect their housings and, in doing so, prevent their reliable operation. The XS1/XS2 M series is particularly well adapted to the severe environment, such as machine tool applications. NOTE: The cables used conform to standard NFC 32 206 and to recommendations CNOMO E03-40-150 N. They are UL Listed and CSA Certified. * Chemical products, such as salts, halophytic and aromatic oils, petrols, acids, and diluted bases. For acids, ketones, and phenols, preliminary test should be made according to the nature and concentration of the liquid. * Agriculture and food industry products, such as animal and vegetable based food products (vegetable oils, animal fat, fruit juice, dairy proteins, etc...). NOTE: For specific details, please consult factory. Have the following information available when making the inquiry: * type of substance * concentration * maximum temperature * specific sensor(s) part numbers considered for the application 345 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors The series XS4P plastic cylindrical proximity sensors as well as the stainless steel XS1/ XS2 sensors exhibit excellent overall resistance to: Proximity Sensors Environmental Parameters Environmental Parameters Shocks ibrations hocks - V S * The sensors are tested according to IEC 60068.2.27, 50g, duration 11 m sec. Vibrations * The sensors are tested according to IEC 60068.2.6, amplitude 2 mm, F = 10-55 Hz, 25g to 55 Hz. Degrees of protection * IP67 - protection against the effects of immersion, tested according to IEC 60529. Sensor immersed for 30 minutes in 1 meter of water. * UL Listed: typical NEMA 4X, 6P, 12. No deterioration in either operating or insulation characteristics. Proximity Sensors * IP68 - protection against effects of prolonged immersion: the test conditions are subject to agreement between the manufacturer and user. Telemecanique selected machine tool applications or other machines frequently drenched in cutting fluids. IP68 means, in this case, cutting oil proof, a degree of protection requiring a superior encapsulation technology. Extensive testing is performed--1500 hours immersion in fluid at 70 C. 346 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Definition of Terms Definition of Terms of Definition nces ista sensing d Standard metal target Output Output ON OFF Su max S u max + H Sr max S r max + H Sn Sn + H Sr min Su min S a Certain detection S r min + H Su min + H Sensing face Nominal (or rated) sensing distance Sn: The rated operating distance for which the sensor is designed. It does not take into account manufacturing tolerances, or any change in supply voltage, temperature, etc... during operation. Used for selection and base for exact calculations. Real sensing distance Sr: The real sensing distance is measured at rated voltage (Un) and at the rated ambient temperature (Tn). It must be between 90% and 110% of the real sensing distance: 0.9Sn Sr 1.1Sn. Usable sensing distance Su: The usable sensing distance is measured at the limits of the permissible variations of the ambient temperature (Ta) and the supply voltage (Ub). It must be between 90% and 110% of the real sensing distance: 0.9Sr Su 1.1Sr. Operating zone Sa (usable sensing range): The operating zone is between 0 and 81% of the nominal sensing distance Sn: 0 Sa 0.81Sn This is the operating zone of the sensor and corresponds to the area within which detection of the standard metal target is certain whatever the variations in voltage or temperature. This is the maximum sensing distance the designer should consider for all applications. Correction factors should be considered only when conditions preclude the use of the standard target in the operating temperature and voltage range. 347 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Proximity sensor Proximity Sensors Definition of Terms Definition of Terms Standard metal target: metal Standard t targe 1 mm thick, square mild cold rolled steel, type FE 360. The side of the square is either equal to the diameter of the sensor or of the circle engraved on the active face of the sensing face or is 3 times the nominal sensing distance (Sn). The higher of these values is used. Frontal approach l Differentia travel Standard target Drop-out point Pick-up point H Sensing distance Proximity Sensors Proximity sensor Differential travel: (hysteresis) H: The distance between the pick-up point as the standard metal target frontally approaches the sensor, and the drop-out point as it moves away. Expressed as a percentage of the real sensing distance Sr. Repeat accuracy (repeatability) R: curacy Repeat ac bility (Repeati aterial Class 2 m lation Double Iso Symbol The repeatability of the sensing distance, between successive operations. Readings are taken over a period of time while the sensor is subjected to environmental extremes, e.g. 8 hour cycle between 10 and 30 C, with supply voltage variation 5% of nominal. Expressed as a percentage of the real sensing distance Sr. Important parameter for positioning applications. Class 2 material - Double isolation The symbol represents electrical insulation conforming to IEC 60536 class 2. It means that all live parts are isolated inside the housing and touching any exterior exposed metal is harmless. No groundings required. International symbol for proximity switches. 348 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Definition of Terms Definition of Terms mA Supply r Leakage o urrent Residual c (lr) XS Load The leakage or residual current corresponds to the current flowing through the sensor in the OFF or "open" state. Important for 2 wire proximity sensors. op Voltage dr (Ud) V Supply Load The voltage drop corresponds to the voltage at the proximity sensor's terminals in the ON or "closed" state.Especially important for 2 wire proximity sensors. Power supply E TIME RESPONS delay power-up Sensor output t The period of time between energizing the sensor and its fully operational condition. Known also as "warm-up" or "first-up" delay. operating Maximum frequency Proximity sensor 1/2 Sn m Standard metal target 2m Non metallic material Output signal T on T off 1 f= (T on + T off) The maximum number of targets a proximity sensor can detect in a second, under standard test conditions (standard EN50018, IEC 60947.5.2). Do not use for selection or design purposes unless the geometry of the application is identical with the one in the picture. 349 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors XS Proximity Sensors Definition of Terms Definition of Terms Presence of the target Present Absent Response time Proximity sensor output signal Ra ON Rr OFF ON delay Ra: The period between the detection of the target and the subsequent change in its output state. This design parameter determines the relationship between the speed of travel and the size of the target. OFF delay Rr: Proximity Sensors The period between the exit of the target from the sensor's operating zone and the subsequent change in its output state. This design parameter limits the interval between successive targets. nal Output sig N.O. - Normally open Output circuit turns ON output current when a target is present. XS ut "NO" outp N.C. - Normally closed Output circuit turns OFF output current when a target is present. XS ut "NC" outp N.O. + N.C. XS Complementary outputs proximity sensor with two outputs, one of which opens, the other closes when a target is present. NO + NC output 350 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Sensing Distance Correction Factors Sensing Distance Correction Factors In practice, most targets are generally made of steel and are of a size, equal to or greater than the sensing face of the sensor. Where this is the case, use the sensing distance values given in the characteristics for the particular sensor. To calculate the precise sensing distance for specific applications, the following parameters, which affect the sensing distance, must be taken into account. K K Temperature 1,1 Real sensing distance l Theoretican calculatio 0,9 -25 0 20 50 70 temperature C Apply a correction factor K to be determined using the curve above. Km Material Proximity Sensors 1 0,5 magn. type 316 type 304 Stainless steel A37 UZ33 AU4G Cu Steel Brass Alum. Copper Target material correction coefficient Km Target Material Mild Steel Brass Aluminum Magn. Stainless Steel Type 316 Type 304 A37 UZ33 AU4G Copper CU Km 1.00 0.70 0.30 1.00 0.37 0.35 0.30 Apply a correction factor Km to be determined using the graph above. Km Thickness 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 Typical curve for a copper target with an 18mm dia. cylindrical model 0.1 0.2 0.3 0.4 0.5 1 1.5 thickness in mm Special case of a very thin target object made of non-ferrous material. Application tip: Aluminum foil on a nonmetallic surface makes an excellent target. 351 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Sensing Distance Correction Factors Sensing Distance Correction Factors Kd Dimension 1 0.9 0.8 0.7 0.6 0.5 0.4 0,3 0.2 0.1 Sn 2Sn 3Sn 4 Sn length of the object to be detected Apply a correction factor Kd to be determined using the curve above. Proximity Sensors For all situations, use the general correction factor Kt = 0.9 for power supply variations within the entire voltage range. nsing Usable se ce distan n Calculatio le examp Sa = Sn x K x Km x Kd x Kt Where Sa = usable sensing distance Sn = nominal sensing distance Proximity sensor XS7C40MP230 with nominal sensing distance Sn = 15 mm. Ambient temperature variation 0 C to + 20 C. Target characteristics: material: Steel dimensions: 45 mm x 45 mm x 1 mm The operating zone, Sa can be found using the formula: Sa = Sn x K x Km x Kd x Kt Sa = 15 x 0.98 x 1 x 0.95 x 0.9 Sa = 12.5 mm umb For standard targets, the rule of thumb is: Sa = 0.8 Sn Rule of th Note st! Always te The above curves are typical curves only. They are given as a guide to the approximate usable sensing distance of a proximity sensor for a given application 352 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Mechanical Installation Mechanical Installation * Patented design * No adjustment replacement Indexed mounting bracket XSZB * Insert the sensor in the bracket until it butts against the stop. STEP 1 Mounting * Secure the sensor using V screw. Proximity Sensors STEP 2 screw V * Adjust the sensor/bracket combination to assure detection. STEP 3 * Secure the combination using F screws. screws F If for any reason adjustment or replacement is necessary: - Unscrew screw V - Butt the new sensor against the stop. Once screw V has been tightened, the new sensor will be indexed in the same position as the old one. No adjustment is necessary. Note: these functions are similar to those of a block type sensor 353 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Mechanical Installation Mechanical Installation Tubular proximity sensor 3 Sn metal istances Clearing d dia. 3 dia. metal 2 Sn Target Versions not suitable for flush mounting in metal (non-shielded) Proximity Sensors Extended range model Standard model 3 Sn 3 Sn metal metal metal 0,2 dia metal Target Versions suitable for flush mounting in metal (shielded) * Versions suitable for flush mounting in metal e (min): 0 metal * Versions not suitable for flush mounting in metal M8 e (min): 5 mm M12 e (min): 8 mm e (mm) M18 e (min): 16 mm M30 e (min): 30 mm Mounting with XSZ B mounting bracket 354 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Mechanical Installation Mechanical Installation Block type proximity sensors not suitable for mounting in metal Non-shielded Mounting into a T section Mounting into a U section tances metal metal Sensing face 2a 1,5 a is Clearing d Sensing face 2a 1,5 a a a 2a metal metal 2a Sensing face 3 Sn 3 Sn metal Sensing face Proximity Sensors metal 1,5 a a a 2a metal metal metal Sensing face 1,5 a Sensing face a 3 Sn 2a metal 40 a 3 Sn metal 40 Side by side e Side by sid ce Face to fa e metal Face to face e NOTE: For shorter distances, alternate frequency models are required. Call factory for availability. 355 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Mechanical Installation Mechanical Installation Suitable for flush mounting in metal e Shielded Mounting with metal on one or more sides simultaneously metal Proximity Sensors e (min): 0 not to be recess mounted not to be mounted adjacent to an angle section metal metal Any metal within the immediate vicinity of a proximity sensor distorts the magnetic field around the sensing face. The clearance distances shown above are given for a simplified installation arrangement and would result in the increase of the sensing distance of less than 5%. 356 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Mounting Tips Mounting Tips Protection of the cable incorrect recautions P incorrect F CNOMO adaptor correct protective sleeve Do not exert a pulling force of over 4.4 lb on the sensor cable. Sensor on moving support Consider using a protective sleeve or rigid conduit, where necessary. 10 cm Cable clamps mobile carrier fixed support Avoid repetitive flexing movement between the cable and the sensor. Protection of the sensing face The sensor must never be used as a mechanical stop as this may cause irreparable damage. 357 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors correct Proximity Sensors Mounting Tips Mounting Tips Use of tools for adjustment of the proximity sensor appropriate tool Proximity Sensors Incorrect Correct Mounting Tubular sensor Block type sensor Ensure a rigid mounting the mounting must be sufficiently rigid and thick to resist shock and vibrations Ensure a rigid mounting the mounting area must be large enough to support the sensor correctly 358 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Mounting Tips Mounting Tips Positioning Sensing face ns Precautio Top Top Bottom Bottom Sensing face Sensing face Correct Proximity Sensors Incorrect * danger of debris collecting on the sensor sensing face * danger of liquid entry should the cable gland be mounted improperly Mechanical protection A proximity sensor should never be used as a footrest Where the possibility of this type of abuse exists, a protective cover should be fitted over the sensor Remember: For proper installation, the sensor must be mounted solidly to its support. Depending on the application, the adjustment of the operating distance is carried out: * either by moving the mounting bracket * or by adjusting the target 359 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors PLC Compatibility PLC Compatibility In order for a solid state, 2 wire, AC sensor to be directly compatible with a PLC, two conditions have to be met: 1. Leakage current: (I off) less than 1.7 mA (Off state) V supply Sensor Rb 2. Load current: greater than the sensor minimum load current (ON state). Typical PLC input currents (load current, I load) are 12-16 mA. Typical values for PLC input resistance (Rin) are: 7.5-10 k. For sensors which do not meet both of the requirements, a Bleeder Resistor (Rb) has to be wired in parallel with the load. For each of the two situations, the Bleeder Resistor parameters have to be calculated as shown below. The smaller value should be selected for the application. Rin PLC 1. Rb = Where: Rin x Vo Max I off (Rin) - Vo max Vo max Rin Vs Pb Pb = Vs2 Rb = PLC input maximum OFF voltage (20-40 Vac) = PLC input resistance = Line voltage = Minimum Bleeder Resistor power rating Proximity Sensors Example: I off Vo max Rin = 3.5 mA = 20 V = 6.5 k Typical examples for Telemecanique TSX DET input modules: TSX DET 1604 TSX DET 0804 For I off = 3.5 mA 47 k/0.5 W -- For I off = 7 mA 4.7 k/3 W 12 k/1.5 W 2. Rb = Rin x Vo Max I off (Rin) - Vo max Pb = Vs2 Rb Example: I min Vs Rin = 30 mA = 120 V = 7 k Typical examples using TSX programmable controllers: TSX DET 1604 For I min = 20 mA 64 k/0.5 W For I min = 30 mA 8.7 k/2 W TSX DET 0804 24 k/1 W 8.7 k/2 W NOTE: All DC 3 wire sensors are PLC compatible. 360 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Electrical Installation Electrical Installation Wiring two or more sensors in series 2 wire type Wiring in series V supply V supply Sensor "n" Sensor " 1" Proximity Sensors load The following points should be considered: 1. When in the open state, each sensor will share the supply voltage: voltage across the sensor = V supply n proximity sensors V sensor and V supply must fall within the sensor's voltage range. 2. If a sensor is OFF, it will be supplied with nearly all the supply voltage. 3. When all sensors are ON, a small voltage drop is present across each sensor; the resultant loss of voltage at the load will be the sum of the individual voltage drops, and the load voltage should be selected accordingly. 4. Series connection is only possible for sensors with a wide voltage range. Example: Four sensors rated at 24-240 Vac can be wired in series at 120 V because even at 90%, V supply = 108 V. When all sensors are OFF, each will see 108/4 = 27 V, which is higher than the minimum voltage rating of the switch (24 V). 361 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Electrical Installation Electrical Installation Wiring two or more sensors in series 3 wire type Sensor "1" Sensor "2" Sensor "n" Proximity Sensors load V supply + V supply - The following points should be considered: 1. Sensor 1, when conducting its load current, will also carry the leakage currents of all other sensors. 2. Each sensor, when conducting, will produce a voltage drop of 2.6 V, maximum. The load voltage should be selected accordingly. 3. Sensor 2 is powered only when Sensor 1 turns ON. Only after its power-up delay will Sensor 2 be able to function properly. This delay should be taken into consideration when speed is a factor. 4. Use of "flywheel" diodes is recommended where an inductive load is being switched. 362 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Electrical Installation Electrical Installation Wiring proximity sensors in series with mechanical contact devices V supply + Wiring in series V supply Sensor load fuse Mechanical contact 1. 2. When the mechanical contact is open, the sensor is not supplied. When the contact closes, the proximity sensor will not operate until a certain time "T" has elapsed, corresponding to the power-up delay. Please refer to details of individuals sensor characteristics . Wiring several sensors in parallel 2 wire type The use of proximity sensors wired in parallel either between themselves or together with mechanical contacts is not recommended. When one of the sensors is in the ON state, the sensor in parallel is "shorted out" and thus no longer supplied. As the first unit passes into the OFF state, the second sensor will become energized and will be subject to its power-up delay. This configuration is used where the sensors are working alternately. When the sensors are OFF, the sum of the leakage currents must be less than the holding current of the load. 3 wire type V supply + V supply - Sensor "1" Sensor "n" load No restriction 363 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors The following points should be considered: Proximity Sensors Electrical Installation Electrical Installation Length of the cable ns Precautio No restrictions up to 660 feet (200 meters) or up to a line capacitance of 0.1 F. It is important to take into account voltage drop on the line over 660 feet (200 meters). The XS models are immune to electrical interference encountered in normal industrial conditions. Where extreme electrical noise conditions could occur (large motors, spot welders, etc.) it may be advisable to protect against transients in the following ways: Suppress interference at source, limit the length of the cables, separate power and control wiring from each other, ensure that the logic systems contain input transient suppression means and use twisted pair and shielded cables. Separation of power and control wiring Proximity Sensors conduit high voltage or power cables incorrect Incorrect correct 10 cm 4 in control cables * power cables Correct * Use of individual cables is recommended if long lengths are involved. 364 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Wiring Tips Wiring Tips Electrical connections to be avoided solution ns Precautio + + R XS XS If the load consists of an incandescent lamp, the cold state resistance can be ten times lower than the hot state resistance. This can cause very high current levels on switching Install a pre-heat resistance in parallel with the proximity sensor. 2 R= V x 10 P V= supply voltage P= power of lamp Load AC AC XS An XS proximity sensor cannot be connected directly to an AC supply source. This would result in immediate destruction of the sensor and considerable danger to the operator (except short circuit protected switches) XS A suitable load (see product data) must be connected in series with the proximity sensor. 365 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors - - Proximity Sensors Troubleshooting Guide Troubleshooting Guide Possible cause Problems Output failure, or the short circuit protection has operated. The sensor's output will not change state when a metal target is moved within its operating zone. Proximity Sensors Wiring error Supply problems False or erratic operation with or without the presence of the target object. Transients Remedial action * Check that the sensor is the correct one for the supply being used. * Check the load current. Characteristics: - If load current is greater than the max. rated current, a relay should be interposed between the sensor and the load. - If load current is lower than the nominal rated current, check for wiring faults which could have caused a short circuit. In any case, a fast-blow fuse should be wired in series with the sensor (AC). - For a tubular sensor, if the sensor is brand new, check the mounting torque. * Check the wiring. * Check voltage range. * Check that the supply voltage falls within the operating limits of the sensor in question. Remember that with a rectified supply: Vpeak = Vrms x 2 * Install transient suppressors across potential sources (coils, arcing contactors) * Refer to the instruction sheet supplied with the sensor. Effect of interference on the supply lines * Ensure that any DC supplies when derived from rectified AC, are correctly filtered (C 400 f) * Ensure that AC power cables are run separately from low level DC cables. * Where very long distances are involved, use suitable cable: - shielded and/or twisted pair - suitable wire gage * Position the sensor as far away as possible from any source of interference. Response time of the sensor too long for * Check suitability of the sensor for the target; choose a sensor with a faster the particular target. response time or use a longer target. * Eliminate sources of radiated heat, or Effects of high temperature protect the housing with a heat shield. Influence of surrounding metal 366 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02 Proximity Sensors Troubleshooting Guide Troubleshooting Guide Block type Cylindrical Form C Form D EN 50008 (NFC 63-076) DC 3 or 4 terminals EN 50040 (NFC 63-071) DC 2 terminals EN 50036 (NFC 63-081) AC terminals EN 50025 (NFC 63-077) DC 3 or 4 terminals EN 50037 EN 50026 (NFC 63-078) DC 3 or 4 terminals EN 50038 (NFC 63-083) AC 2 terminals (NFC 63-082) AC 2 terminals Proximity Sensors Cenelec standards Form A EN 50010 (NFC 63-075) Determination of sensing distance and operating frequencies EN 50032 (NFC 63-079) EN 50040 (NFC 63-074) Definitions, classification, description Connection identification Series XS1/XS2 N, XS1/XS2 M, XS4 P also conform to the requirements of IEC 60947.5.2 standard. (ISO 9000 Self-Certification, NEMA project ICS 5-4-199X) USSR Approvals File LR46094 + LR44087 class 321103 File E39291 guide NKCR2 File E39281 guide NKCR Standard version approved pending Special North American version (1/2" NPT cable entry, UL label, etc.) FM Intrinsically safe applications XS1 / XS2 L/N XS1 / XS2 M XS4P XSB XS7 / 8 XSD XSE XSG XS5 XS6 XS7 XS8 XS9 367 10/02 (c) 1997-2002 Schneider Electric All Rights Reserved Proximity Sensors Proximity Sensors 368 (c) 1997-2002 Schneider Electric All Rights Reserved 10/02